Digital Cam Switch Unit
CamCon DC50/51
For your attention
This instruction manual relates to the CamCon DC50/51 from 10/2003. The company Digitronic
Automationsanlagen GmbH reserves the right to make changes which present an improvement of the
quality or functionality of the device without prior notice. The instruction manual was created with great
care, although it may not be error-proof. We would be grateful for any communication relating to any
errors you may have found.
UP-date
You can also obtain this instruction manual on the Internet at http://www.digitronic.com in the latest
version as PDF file.
Qualified personnel
This device may only be started and operated by qualified staff. By qualified we mean personnel who
are entitled to handle, to earth and to lable devices, systems and power circuits in accordance with the
technology safety standards.
Liability
(1) The supplier is liable for damages caused by himself or by the owner of the rights up to the sum of
the sales price. He is not liable for loss of profits, forfeited savings, intermediate and successive
damages.
(2) The above mentioned limits to liability do not apply to insurance of named characteristics and
damages which were caused deliberately or through negligence.
Protection
The CamCon DC50/51 and this instruction manual are protected by copyright. All rights are reserved.
Neither the CamCon DC50/51, nor this document may be copied as a whole or partially, photocopied,
reproduced, translated or transferred to electronic media of any kind or into machine readable format
without prior written permission by the company Digitronic Automationsanlagen GmbH.
Note:
Note:
Note:
We have examined the devices of the CamCon series for year 2000 compatibility and
have not found any adverse effects on any functions.
CamCon is a registered trademark of the company Firma Digitronic
Automationsanlagen GmbH.
The devices of the CamCon series comply with the standards for electromagnetic
compatibility: EN 55011, EN 55022, EN 55024 Part 2, EN 50082 Part 2, ENV 50140,
VDE 0843 Part 2,
VDE 0843 Part 4,
VDE 0871,
VDE 0875 Part 3 ("N"),
VDE 0875 Part 11, VDE 0877 Part 2, IEC 801 Part 3, IEC 801 Part 2, IEC 801 Part 4,
IEC 801 Part 5.
(c) Copyright 1992 - 2004 / File: DC50E.DOC
Digitronic Automationsanlagen GmbH
Auf der Langwies 1
D-65510 Hünstetten - Wallbach
Tel. (+49)6126/9453-0 Fax. (+49)6126/9453-42
Internet: http://www.digitronic.com
E-Mail: [email protected]
,Version from: Aug. 04
Page: 2
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
TABLE OF CONTENTS
1. Introduction .......................................................................................................................................... 8
2. Operating Pinciples.............................................................................................................................. 9
2.1. Speed Compensation ..................................................................................................................... 10
2.1.1. Measuring delay time for Speed Compensation.......................................................................... 12
2.1.1.1. Measuring delay time through actual differences ..................................................................... 12
2.1.1.2. Measuring delay time by means of different measuring points................................................. 12
2.1.2. Speed Compensation using off-centre pressure, e.g. brake functions........................................ 13
2.1.3. Separate delay time for Speed Compensation of switch-ON and switch-OFF points ................. 14
2.2. Time - Cam ..................................................................................................................................... 14
3. Installation .......................................................................................................................................... 15
3.1. Dimensions ..................................................................................................................................... 15
4. Electrical connections ........................................................................................................................ 16
4.1. Pin allocation of the CamCon ......................................................................................................... 16
4.1.1. Pin allocation of the analog output............................................................................................... 16
4.1.2. Pin allocation of the SSI measuring system................................................................................. 16
4.1.3. Pin allocation of the incremental measuring system.................................................................... 17
4.1.4. Pin allocation of the inputs ........................................................................................................... 17
4.1.5. Pin allocation of the outputs......................................................................................................... 17
4.1.6. Pin allocation of the voltage supply.............................................................................................. 18
4.1.7. Pin allocation of the serial interface ............................................................................................. 18
4.1.7.1. Pin allocation of the serial RS232 interface .............................................................................. 18
4.1.7.2. Pin allocation of the serial RS485 interface .............................................................................. 19
4.1.8. Pin allocation of the external interface......................................................................................... 20
4.2. The measuring system.................................................................................................................... 21
4.2.1. SSI Measuring system input ........................................................................................................ 21
4.2.2. Parallel measuring system input .................................................................................................. 21
4.2.3. Incremental measuring system input ........................................................................................... 22
4.2.3.1. Incremental measuring system input with 5V RS422 level....................................................... 22
4.2.3.2. Incremental measuring system input with 24V PNP level......................................................... 22
4.2.3.3. Incremental Hiperface measuring system input with SINCOS level......................................... 23
4.2.4. Analog measuring system input................................................................................................... 23
4.2.5. PLL measuring system input........................................................................................................ 24
4.2.6. Timer as a measuring system...................................................................................................... 24
4.2.7. RS232 as a measuring system .................................................................................................... 24
4.3. The outputs ..................................................................................................................................... 25
4.3.1. The 40mA outputs (only CamCon device with aluminium back wall) .......................................... 25
4.3.2. The 500mA outputs...................................................................................................................... 25
4.4. The inputs ....................................................................................................................................... 25
4.5. Precautionary measures for welding work ...................................................................................... 25
5. Outline of the operator terminal ......................................................................................................... 26
5.1. Frontview CamCon ......................................................................................................................... 26
5.2. The liquid crystal display (LCD) ...................................................................................................... 26
5.3. Contrast setting............................................................................................................................... 26
5.4. The keyboard .................................................................................................................................. 26
5.5. Outline of key functions................................................................................................................... 27
5.6. Menu selection................................................................................................................................ 27
5.7. Selection of a menu point ............................................................................................................... 27
5.8. Text input ........................................................................................................................................ 28
6. Commissioning .................................................................................................................................. 29
7. Operation of the CamCon.................................................................................................................. 31
7.1. The main menu............................................................................................................................... 31
7.2. The standard display....................................................................................................................... 31
,Version from: Aug. 04
Page: 3
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.2.1. Changing the display.................................................................................................................... 31
7.2.2. Program change .......................................................................................................................... 32
7.2.3. Program name ............................................................................................................................. 32
7.3. Cam programming .......................................................................................................................... 33
7.3.1. Output selection for programming ............................................................................................... 33
7.3.2. Program selection for programming ............................................................................................ 34
7.3.3. Programming the delay time/speed compensation...................................................................... 34
7.3.4. Programing Time-Cams............................................................................................................... 35
7.3.5. Programming the output name .................................................................................................... 36
7.3.6. Cam Input .................................................................................................................................... 36
7.3.7. Adding cams ................................................................................................................................ 37
7.3.8. Cam Teach - In ............................................................................................................................ 37
7.3.9. Cam Search ................................................................................................................................. 37
7.3.10. Cam deletion.............................................................................................................................. 38
7.3.11. Output (cam track) deletion ....................................................................................................... 38
7.3.12. Copying programmed outputs (cam tracks)............................................................................... 39
7.3.13. Shifting cam tracks .................................................................................................................... 39
7.3.14. Deleting programs...................................................................................................................... 40
7.3.15. Copying programs...................................................................................................................... 40
7.3.16. Examples for cam programming................................................................................................ 41
7.3.16.1. First cam programming........................................................................................................... 41
7.3.16.2. Programming additional cams on an output ........................................................................... 42
7.3.16.3. Deletion of a particular cam .................................................................................................... 43
7.3.17. Programming analog cams........................................................................................................ 44
7.3.17.1. Creating the first analog cam .................................................................................................. 45
7.3.17.2. Adding an analog cam ............................................................................................................ 45
7.3.17.3. Changing the analog cam ....................................................................................................... 45
7.4. Unit configuration (system setting).................................................................................................. 46
7.4.1. Measuring system........................................................................................................................ 46
7.4.1.1. The standard measuring systems............................................................................................. 46
7.4.1.2. The actual position hysteresis................................................................................................... 46
7.4.1.3. Controlling the measuring system............................................................................................. 47
7.4.1.4. The electronic gear ................................................................................................................... 48
7.4.1.4.1. Electronically changing the rotation direction......................................................................... 48
7.4.1.5. The display format of the actual position .................................................................................. 48
7.4.1.6. Configuration of a special measuring system ........................................................................... 49
7.4.1.6.1. SSI - measuring system......................................................................................................... 49
7.4.1.6.2. Parallel - Gray measuring system.......................................................................................... 50
7.4.1.6.3. Incremental - measuring system............................................................................................ 50
7.4.1.6.4. Multiturn measuring system with electronic gear................................................................... 51
7.4.1.6.5. PLL measuring system .......................................................................................................... 52
7.4.1.6.6. Timer way simulation (time emitter)....................................................................................... 52
7.4.1.6.7. RS232 measuring system...................................................................................................... 53
7.4.1.6.8. AG615 - Single - Multiturn - Measuring system ..................................................................... 53
7.4.1.6.9. SIM - measuring system simulator ........................................................................................ 54
7.4.1.6.10. HIPER i.e. incremental - measuring system with Roll - Over - funktion.............................. 54
7.4.1.7. Deleting the special measuring system .................................................................................... 55
7.4.2. The measuring offset ................................................................................................................... 56
7.4.2.1. Zero offset with rotatory movements......................................................................................... 56
7.4.2.2. Measuring offset with a linear moved system........................................................................... 56
7.4.2.3. Zero offset with linear movements............................................................................................ 56
7.4.2.4. Actual position preset................................................................................................................ 57
7.4.3. The speed adjustment ................................................................................................................. 58
7.4.3.1. The speed factor....................................................................................................................... 58
7.4.3.2. The display format of the speed display ................................................................................... 58
7.4.3.3. Range adjustment of the speed display.................................................................................... 58
7.4.3.4. Accuracy of the speed display .................................................................................................. 59
7.4.3.5. Display, Type ............................................................................................................................ 59
,Version from: Aug. 04
Page: 4
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.4.4. Cable length / Cycle time ............................................................................................................. 60
7.4.4.1. The cable length ....................................................................................................................... 60
7.4.4.2. The cycle time of the CamCon.................................................................................................. 60
7.4.5. The special outputs...................................................................................................................... 60
7.4.5.1. The security output.................................................................................................................... 60
7.4.5.2. The output of the actual position............................................................................................... 61
7.4.5.3. Direction output......................................................................................................................... 61
7.4.5.4. The standstill output.................................................................................................................. 61
7.4.5.5. The hysteresis........................................................................................................................... 61
7.4.5.6. The analog speed output .......................................................................................................... 62
7.4.5.7. Configuration of the analog cams ............................................................................................. 62
7.4.5.8. The analog position output........................................................................................................ 64
7.4.6. System upgrading ........................................................................................................................ 64
7.4.6.1. Setting the inputs ...................................................................................................................... 64
7.4.6.2. Setting the outputs .................................................................................................................... 64
7.4.6.3. Setting the outputs with speed compensation .......................................................................... 64
7.4.6.4. Setting the keyboard lock.......................................................................................................... 64
7.4.6.5. Error - aknowledging Input (EQ) ............................................................................................... 64
7.4.6.6. Input for enableling Outputs...................................................................................................... 64
7.4.6.7. Setting the external program selection ..................................................................................... 65
7.4.6.8. Setting the program selection mode ......................................................................................... 65
7.4.7. Masterprogram............................................................................................................................. 66
7.5. Unit configuration ............................................................................................................................ 67
7.5.1. User key allocation....................................................................................................................... 67
7.5.1.1. Creating a new user key ........................................................................................................... 67
7.5.1.2. Deletion of a user key ............................................................................................................... 68
7.5.1.3. Checking the key configuration................................................................................................. 68
7.5.2. Complete deletion ........................................................................................................................ 69
7.5.3. Unit configuration ......................................................................................................................... 70
7.5.3.1. Setting the serial interface ........................................................................................................ 70
7.5.3.1.1. The "Cam-BUS" communication mode.................................................................................. 70
7.5.3.1.2. The "Standard" communication mode ................................................................................... 70
7.5.3.1.3. The "Multiuser" communication mode ................................................................................... 70
7.5.3.1.4. The "S5 - L1" communication mode ...................................................................................... 70
7.5.3.1.5. The "3964(R)" communication mode..................................................................................... 70
7.5.3.1.6. Input of the unit number......................................................................................................... 71
7.5.3.1.7. Programming via remote ....................................................................................................... 71
7.5.3.2. Additional device options .......................................................................................................... 71
7.5.3.2.1. PLC Logic Module.................................................................................................................. 71
7.5.3.2.1.1. Examples for using the PLC logic module .......................................................................... 71
7.5.3.2.2. PLC Logic Module with text display ....................................................................................... 72
7.5.3.3. Analog outputs .......................................................................................................................... 73
7.5.3.3.1. Clearing the integrated analog outputs .................................................................................. 73
7.5.3.3.2. Adjusting the integrated analog outputs................................................................................. 73
7.5.3.3.3. External analog outputs ......................................................................................................... 73
7.5.3.4. Locking EEProm memory ......................................................................................................... 74
7.5.4. Language ..................................................................................................................................... 75
7.5.5. Configure user ............................................................................................................................. 75
7.5.5.1. User text.................................................................................................................................... 75
7.5.5.2. User-Menu/OP-functions .......................................................................................................... 76
7.5.6. Configure Hardware..................................................................................................................... 76
7.5.6.1. CP16 Module ............................................................................................................................ 76
8. Device info ......................................................................................................................................... 77
8.1. Stack Info ........................................................................................................................................ 79
9. Error messages and removal of errors (FAQ) ................................................................................... 80
9.1. Problem: Display shows "No contact to unit: XX". .......................................................................... 80
9.2. Problem: "Pos - Err:1"..................................................................................................................... 80
9.3. Problem: "Pos - Err:2"..................................................................................................................... 80
9.4. Problem: "Pos - Err:3"..................................................................................................................... 81
,Version from: Aug. 04
Page: 5
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
9.5. Problem: "Pos - Err:5"..................................................................................................................... 81
9.6. Problem: An "Pos-Error:" occurs during operation.......................................................................... 81
9.7. Problem: "RAM-Full" = RAM memoryis full..................................................................................... 81
9.8. Problem: The EEProm memory is full............................................................................................. 82
9.9. Problem: Outputs will not activate................................................................................................... 82
9.10. Problem: "Out - Error". .................................................................................................................. 82
9.11. Problem: Error in the EEPROM. ................................................................................................... 82
9.12. Problem: "Error ???" ..................................................................................................................... 82
9.13. Problem: "Clear...."........................................................................................................................ 83
10. Menu outline..................................................................................................................................... 84
11. Calculation EEPROM cam storage.................................................................................................. 85
12. Calculation the RAM storage-requirement for CamCon .................................................................. 86
13. Technical data of the CamCon ........................................................................................................ 87
14. Key word table ................................................................................................................................. 88
,Version from: Aug. 04
Page: 6
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
1. Introduction
Electronic Cam Switch Units have been successfully used in industry for a long time. Experiences
collected in close liaison with users over the years have been included in the development of the
CamCon series. The result is a compact digital cam switch unit which is user friendly and reliable to a
high degree. The following characteristics testify the excellence of the CamCon:
*
Tested and reliable hardware
*
Short-circuit-proof outputs
*
Graphic liquid crystal display with 128x64 pixels in the CamCon DC50,51.
*
Large
and
clearly
visible
7-Segment
display
for
program,
position
and
speed
on
CamCon DC30,33 and 40.
*
Any number of cams per output can be programmed.
*
Up to 32000 Programs for product administration
*
Master, for example: machine cams
*
Optimising switch points when machine is in operation
*
Compensation of mechanical delay time of switch components for switch-ON and switch-OFF
points can be set in steps of 100µs separately (DTC = delay time or Speed Compensation).
*
Position - Triggert - Time - Cams
*
Power supply 24V DC +/- 20%
*
Mounting of suspension rails to EN 50022 on CamCon DC16 and 90
*
Switchboard panel standard casing 144 x 144 x 63mm to DIN 43700 on CamCon DC33,40 and 51
*
S5 Components group for S5 115U, 135U and 155U on CamCon DC115
*
S7 Components group for S7 300 on CamCon DC300
*
AB Components group for ControlLogix 1756 on CamCon 1756-DICAM
*
S5 Switch-ON via PG interface with L1 - Bus on CamCon DC16,40,50,51 and 90
*
PLC Logic Module (optional)
*
Shift register (optional)
*
OP - Functions
*
Analog outputs (optional)
Cam switch units are used wherever switching operations are periodically repeated. Digital cam switch
units are an optimum replacement of mechanical units and offer in addition many other advantages,
such as:
*
Simplification of mounting and adjustment operations
*
Repeatable adjustment facility
*
Standardised for almost all areas of application
*
Reliability
*
High switch speed
*
Speed Compensation
*
Product administration for quick format change
,Version from: Aug. 04
Page: 7
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
2. Operating Pinciples
Diagram: Principles of a Cam Switch Unit
A principle for better comprehension of the function of a Cam Switch Unit is here presented. It has 3
outputs with the following cams:
Output 1:
Output 2:
Output 3:
Cam 1:
Cam 2:
Cam 3:
Cam 1:
Cam 2:
Cam 1:
Switch-ON position
Switch-ON position
Switch-ON position
Switch-ON position
Switch-ON position
Switch-ON position
60°
95°
325°
5°
95°
30°
Switch-OFF position
Switch-OFF position
Switch-OFF position
Switch-OFF position
Switch-OFF position
Switch-OFF position
85°
145°
355°
20°
145°
85°
The positions of the output signals, here presented as three tracks, occur when the three cam disks
turn anti-clockwise past a sensor, which scans the cams on the 0°-axis.
In a mechanical cam switch unit, the switch interval, i.e. the range between switch-ON and switch-OFF
position are determined by the length of the cam. The length and the position of the cam can only be
varied marginally and this is mechanically highly demanding and time consuming. With CamCon such
adjustments can be realised in a fraction of time; in addition, there can be any number of tracks. A
measuring system which is fitted to the device reports the position to the CamCon. The CamCon
compares it with the programmed switch-ON and Switch-OFF positions of all outputs. If the position
lies in the range of a programmed switch-ON / switch-OFF position (cam), then the respective outputs
are active.
,Version from: Aug. 04
Page: 8
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
2.1. Speed Compensation
Each mechanical switch component (e.g. shield, magnetic valve) has a delay time, i.e. the time
between the start signal and the actual switching of the contacts. In processes where positioning is
executed on a moving system, this can cause problems. If such a process is driven with different
speeds, different positions are caused. To avoid this happening, new timings for the switch signals of
each speed would have to be calculated.
In order to ilustrate the complicated issues surrounding delay time or speed compensation, this will be
shown on the example of a packaging machine. In the process shown in the diagram, a glue point has
to be placed in an exactly defined spot on a moving paper track.
magnetic valve
The system has the following parameters:
CamCon
vp
vT
d
glue nozzle
-
encoder
drop
TMV paper
Speed of the paper track
Falling speed of the drop of glue
Distance between the glue nozzle and
the paper track
Delay time of the magnetic valve
paper track
Points where the glue
hits the paper at the
different speeds
.
Without speed compensation the following would happen:
As soon as the measuring system has reached a certain position, the CamCon sends a signal to the
magnetic valve. The glue nozzle opens for a short time during which a drop of glue ejects. Between the
start of the impulse and the exit of the drop time passes, which is mainly caused by the delay time of
the magnetic valve TMV.. A further delay is caused by the time which the droplet needs to pass the
distance between the glue nozzle and the surface of the paper.
This flight time is calculated as follows:
d
tFlight = v
T
In total there the delay time is tFlight+TMV. During this time the paper track moves on by a specific
distance x.
It would now be possible to move the position, where the magnetic valve is switched on, forward by a
specific amount, so that the glue droplet hits the same spot again as during standstill. In this way a
speed compensation is created which works only at a specific speed of the paper. As soon as the
speed of the device and consequently that of the paper track is, for example, doubled, the hit point of
the glue droplet is shifted by the distance x, so that, without any speed compensation, it would move
backward by double the distance (2 ⋅ x) in total.
The automatic speed compensation of the CamCon makes it now possible to drive processes with
variable speed; CamCon registers the speed of the device continuously and adjusts the cams which
determine the switch time points "On Line" depending on the speed. This has the effect that the
outputs for the switch components are switched ON or OFF earlier. The direction of the movement is
of no significance in this instance.
,Version from: Aug. 04
Page: 9
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
A small example in figures was designed to eludicate:
Supposing the drive cylinder with the measuring system has a circumference of 360mm, so that one
millimeter of the circumference corresponds to exactly one angle degree of the measuring system.
The device has the following parameters:
vdroplet
d
TMV
=
=
=
20m/s
20cm
20ms
This results in the following flight time of the droplet:
d
0,2m
tFlight =
=
10ms
vT
20m/s =
The total delay time is then Tdead, altogether = TMV + tFlight = 20ms + 10ms = 30ms
During this time the paper track moves on by the distance x = vpaper ⋅ Ttotal delay. = 1m/s ⋅ 30ms =
30mm. In order to compensate the delay time, the switch point for the magnetic valve must be moved
forward by 30°.
If the speed of the device and consequently that of the paper is doubled vpaper, then the distance x is
also doubled by the speed of the paper track. In this case the switch point must be moved by 60°.
Note:
Please take into account in these explanations that delay time is of a fixed size, which is
determined by the mechanical constants of the set and switch components and by the
dimensions of the construction and therefore does not change!
If the total delay time of 30ms was programmed into the respective output of CamCon, then the glue
droplet would always hit the right spot, regardless of the speed.
,Version from: Aug. 04
Page: 10
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
2.1.1. Measuring delay time for Speed Compensation
Several ways of measuring delay time of a relay or valve are available.
2.1.1.1. Measuring delay time through actual differences
First the switch-ON point of a valve or relay is programmed. We assume that the programmed switch
point lies at 200 degrees in this case. If the machine is driven with a speed of for example 40 rpm, a
shift occurs due to delay time. This shift is then measured and, in this example, will amount to 40
degrees.
Warning:
For the calculation of the shift the programmed delay time in the cam switch unit must be
set to zero!
The delay time of the switch component is now calculated as follows:
∆ way (in °) * 60 (sec./min.)
Delay time ( in sec. ) = speed (in rpm) * 360 (°/turn)
40 * 60
Delay time ( in sec. ) = 40 * 360 = 0.1667 sec.
The resultant delay time is then entered into the cam switch unit.
See Chapter "7.3.3. Programming the delay time" an page 33.
2.1.1.2. Measuring delay time by means of different measuring points
First the switch point is calculated at a speed of, for example, 50 rpm. We assume that the
programmed switch point lies at 200° in this case. The second measurement is taken at a speed of 80
rpm The necessary switch point must be set to 160°, if the exact switch point is to be also achieved at
80 rpm.
Warning:
For the calculation of the two switch points the programmed delay time in the cam switch
unit must be set to zero!
The delay time of the switch component is then calculated with the following formula:
Delay time ( in sec. ) =
∆ way (in °) * 60 (sec./min.)
∆ speed (in rpm) * 360 (°/turn)
40 * 60
Delay time ( in sec. ) = 30 * 360 = 0.222 sec.
The resultant delay time is then entered into the cam switch unit.
See Chapter "7.3.3. Programming the delay time" an page 33.
Since the entered delay time shifts the switch point, the previously programmed cam must be changed.
For the calculation of the exact switch-ON position, the difference to the speed O rpm (here using 50
rpm) must be added to the first measured switch-ON point (here 200°). The difference is calculated
with the following formula:
∆ way (in degrees) =
dead time ( in sec. ) * ∆ time (in min-1) * 360 (degrees/rotations)
60 (sec./min.)
∆ way (in degrees) =
0.222 * 50 * 360
= 66.6 degrees
60
The switch-ON point of the cam is now shifted from 200° by approx. 67° to 267°.
,Version from: Aug. 04
Page: 11
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
2.1.2. Speed Compensation using off-centre pressure, e.g. brake functions
The Speed Compensation of the CamCon Cam switch unit works using a linear function. If, for
example, the speed doubles, then the shift of the compensated cam changes and also moves forward
by twice the amount. If the ram on an eccentric press should be brought to a standstill at the exact
upper stop point, the brake action of the press under different speeds results in a quadratic function.
The Speed Compensation can therefore only find an approximation of the exact switch point for the
stopping of the press by adjusting the line of the cam lines to the brake curves in the working range of
the press.
In the graphic on the right the curved line represents the
brake point of the ram in relation to the speed.
For the calculation of the parameters to be programmed
please proceed as follows:
-
Define the working range (e.g. 20-50 rpm) and determine
two measuring points which have to be specified in the
working process (e.g. 30 and 40 rpm).
-
Now let the machine run at 30 rpm and program or
optimise a cam without Speed Compensation so that, at
switch-OFF, the ram comes to a halt in top stop. Note the
switch-ON point of the cam (e.g. 340°).
-
Now let the maching work with 40 rpm and program or
optimise one cam without Speed Compensation so that,
at switch-OFF, the ram comes to a halt in top stop. Once
again, note the switch-On point of the cam. (e.g. 332°).
-
Now calculate the delay time, taking into account the
distance and speed difference, using this formula:
Delay time ( in sec. ) =
U/min
Verlauf
Nocke 1
Nocke 2
∆ way (in °) * 60 (sec./min.)
340-332 * 60
= 40-30 * 360 =
∆ Speed (in rpm.) * 360 (°/turn)
0.133 sec.
-
The calculated delay time is now entered into the cam switch unit.
-
Since the switch-OFF point has shifted through the entered Speed Compensation, the previously
programmed cam must be changed first. For the calculation of the exact switch-ON position, the
difference to the speed 0 rpm (here 30 rpm) must be added to the first measured switch-ON point
(first measuring point here 340°) The difference is calculated with the following formula:
∆ way (in °) =
-
delay time ( in sec. ) * ∆ Speed (in rpm.) * 360 (°/turn)
0.133 * 30 * 360
=
= 23.94°
60 (sec./min.)
60
The switch-ON point of the cam has now shifted from 340° by approx. 24° to 364°.
As a result a cam with a switch-ON point of 4° and a speed compensation of 0.133 sec has been
calculated. This is entered in the cam switch unit as switch-OFF cam of the press.
Note:
If the degree of accuracy is no longer sufficient when switch-OFF is done with one cam, two
or several outputs can be switched in parallel and the cam of those is then adjusted to the
required working range. For the calculation of two switch-OFF cams divide the working
range in 5 parts with 4 measuring points and then calculate the delay time value and the
cam value with the same formula as described above. For the calculation of the first cam,
use the measuring points 1 + 2 and for the calculation of the second cam use the
measuring point 3 + 4.
Through this association of the linear cam functions to the brake functions it is now possible to switch
OFF the cam via the entire working range of the press in the top stop.
,Version from: Aug. 04
Page: 12
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
2.1.3. Separate delay time for Speed Compensation of switch-ON and switch-OFF points
For CamCon devices of Software from 3/2002 Speed Compensation is now available for separate
switch-ON and switch-OFF points. This is necessary since some valves need longer to switch OFF
than to switch ON.
Switching attitude of a cam programs from 140° to 200° with 60 min -1.
Cam with 111ms Speed compensation for switch on point and 166ms
compensation for switch off point.
Cam with 111ms Speed compensation.
Cam without Speed compensation.
For the calculation of both delay times the same formuli are used as for a normal compensation. See
Chapter "2.1.1. Measuring delay time for Speed Compensation" on page 11 for entering delay time see
Chapter "7.3.3. Programming the delay time" on page 33.
Attention: If the switch-off-point of a Cam overtakes the switch on point at rising speed, the result will
be an non-defined signal.
2.2. Time - Cam
With nomale cam becomes with increasing plant speed switch-on time ever more briefly. If controlling
a glueing-station, the result would be an insufficent ammount of spreaded glue.
A Time - cam however has with each plant speed a firm temporal length, so that excactly the same
ammount of glue could be spread at changing speeds. The switch-on point of the Cam on a normal as
well as on a Time-Cam is appointed by a position-dependent Position value and a delay-time/speed
compensation.
Normal - cam
Time - cam
60min-1
60min-1
30min-1
30min-1
For CamCon devices of software releases after 3/2002 Time Cam is also available for devices without
PLC - Logic - Module.
For entering a Time - Cam see Chapter "7.3.4. Programing Time-Cams" on page 34.
,Version from: Aug. 04
Page: 13
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
3. Installation
The unit is inserted into a cutout for front plate installation (see chapter "3.1. Dimensions" on page 14).
Connect the groundig pins on the back of the encasement as well as the cable cover to a grounding
point of the switchboard door in the shortest possible way. All cable connections must be done in a
cold state! The connection cables, e.g. for the measuring system or the serial interface, must be wired
with covers, and the covers have to grounded on both ends. Analog signals must also be wired with
covers, and the covers have to be grounded on one end.
3.1. Dimensions
CamCon
DIGITRONIC
front door
can be locked
cutout as per
plug input for encoder
attachment clip
Fig.: Drawing to aid the installation of CamCon
,Version from: Aug. 04
Page: 14
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
4. Electrical connections
4.1. Pin allocation of the CamCon
CamCon
Fig.: Backview of the CamCon with pin allocation
4.1.1. Pin allocation of the analog output
Pin
Pin
Pin
1:
2:
3:
0V signal mass for the analog output
Analog output 1
Analog output 2
4.1.2. Pin allocation of the SSI measuring system
Pin
Pin
Pin
Pin
Pin
Pin
11:
12:
13:
14:
15:
16:
0V voltage supply for the SSI measuring system (encoder)
Data A or +
Data B or Clock A or +
Clock B or +24V DC voltage supply for the SSI measuring system (encoder)
,Version from: Aug. 04
Page: 15
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
4.1.3. Pin allocation of the incremental measuring system
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
11:
12:
13:
14:
15:
16:
17:
18:
19:
20:
0V voltage supply for theincremental measuring system (encoder)
A Imp. (+)
A Imp. (-)
B Imp. (+)
B Imp. (-)
+24V DC voltage supply for the incremental measuring system (encoder)
C1 Imp. (+)
C1 Imp. (-)
C2 Imp. (+)
C2 Imp. (-)
4.1.4. Pin allocation of the inputs
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
21:
22:
23:
24:
25:
26:
27:
28:
29:
30:
31:
32:
33:
34:
35:
36:
37:
38:
39:
40:
0V signal mass for inputs
Input 1
Input 2
Input 3
Input 4
Input 5
Input 6
Input 7
Input 8
+24V DC voltage supply for the outputs 1 to 16
0V signal mass for inputs
Input 9
Input 10
Input 11
Input 12
Input 13
Input 14
Input 15
Input 16
+24V DC voltage supply for the outputs 1 to 16
4.1.5. Pin allocation of the outputs
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
41:
42:
43:
44:
45:
46:
47:
48:
49:
50:
51:
52:
53:
54:
55:
56:
57:
58:
59:
60:
0V voltage supply for the outputs 1 to 16
Output 1
Output 2
Output 3
Output 4
Output 5
Output 6
Output 7
Output 8
+24V DC voltage supply for the outputs 1 to 16
0V voltage supply for the outputs 1 to 16
Output 9
Output 10
Output 11
Output 12
Output 13
Output 14
Output 15
Output 16
+24V DC voltage supply for outputs 1 to 16
,Version from: Aug. 04
Page: 16
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
Pin
61:
62:
63:
64:
65:
66:
67:
68:
69:
70:
71:
72:
73:
74:
75:
76:
77:
78:
79:
80:
Digital Cam Switch Unit
CamCon DC50/51
0V voltage supply for the outputs 17 to 32
Output 17
Output 18
Output 19
Output 20
Output 21
Output 22
Output 23
Output 24
+24V DC voltage supply for the outputs 17 to 32
0V voltage supply for the outputs 17 to 32
Output 25
Output 26
Output 27
Output 28
Output 29
Output 30
Output 31
Output 32
+24V DC voltage supply for the outputs 17 to 32
4.1.6. Pin allocation of the voltage supply
Pin
Pin
Pin
Pin
81:
82:
83:
84:
Attention :
0V voltage supply for the CPU
0V voltage supply for the CPU
+24V DC voltage supply for the CPU
+24V DC voltage supply for the CPU
Pins 30, 40, 50 and 60 are connected to each other.
Pins 1, 11, 21, 31, 41, 51, 61, 71, 81 and 82 are connected to each other.
4.1.7. Pin allocation of the serial interface
When you order the CamCon you can choose the type of the serial interfaec between RS232 or
RS485. Wiring and connector allocation are different for each type of the serial interface.
4.1.7.1. Pin allocation of the serial RS232 interface
DSUB 9 pinboard:
Pin
Pin
Pin
Pin
Pin
1,4
2
3
5
6-9
RS232 Interface for PC attachment (max. 15m cable length)
Do not connect !
TXD
RXD
Mass
N.C.
,Version from: Aug. 04
Page: 17
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
4.1.7.2. Pin allocation of the serial RS485 interface
DSUB 9 pinboard:
Pin
Pin
Pin
Pin
Pin
1,4
2
3
5
6-9
RS485 Interface for PC attachment or for the networking of many devices
(max. 1000m cable length).
Closedown resistors for RS485
B (-)
A (+)
GND
N.C.
CamCon
Interface converter
PC
Interface converter
PC
CamCon
CamCon
CamCon
CamCon
Note:
The pins 1 and 2, as well as the pins 3 and 4 have to be bridged in the
attachment plug of the first and last device in a networked chain at the RS485
Interface, to close the data and reception line perfectly. Corresponding
closedown resistors are attached to the system at pin 1 and 4.
,Version from: Aug. 04
Page: 18
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
4.1.8. Pin allocation of the external interface
If you ordered the external interface along with the CamCon, you have the possibility to extend your
CamCon by a CamCon DC91/IO, DC92/I or DC16/IO. The extensions are clipped on to a rail in the
clipboard. They are connected with a cable with 6 poles, type "KK91/IO-XX" with the 9pole D-Sub male
plug "external Inter in" at the CamCon module (maximum cable length is 300m). The data transfer is
done through optical couplers, so that the connection remains potential free.
For the CamCon DC16/IO a DSUB cable with flatwire adapter can be ordered, order No. "KK50-16/IOXX" (Note: XX refers to the cables length in meters).
DSUB 9 socket:
link of external in - and output modules e.g. DC91
Pin 1,4,7
Pin 2
Pin 6
Pin 8
Pin 3
Pin 5
Pin 9
GND
TxD
TxD
CLK
CLK
RxD
RxD
+
+
+
-
Connection cable CamCon DC91/IO
CamCon
CamCon
DC 91
external
interface
external
interface
OUT
IN
Connection cable CamCon DC91/IO
CamCon DC16/IO
Stift
9
8
6
5
3
2
4
7
1,10
,Version from: Aug. 04
Page: 19
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
4.2. The measuring system
The measuring system is designed to record the necessary actual values (positions) for the Cam
Switch Unit. Many different measuring system can be linked with the CamCon.
See chapter "4.1. Pin allocation" on page 15 and for adjustment of the measuring system to the
software of the CamCons please also consult Chapter "7.4.1. Measuring system" on page 45.
Note: Please also consult the instruction manual for your measuring system.
4.2.1. SSI Measuring system input
Systems with a synchronous series interface = SSI. The SSI interface is widely used in industry for
absolute single and multi-turn angle encoder. At this interface the CamCon supplies the measuring
system with 24Volt. For the purpose of data reading the CamCon sends a stroke signal (clock) with
RS422 level to the measuring system. This answers synchronously with the data output of the position
in the grey code. The frequency of the pulse signal depends on the length of the cable to the
measuring system and can be set in the CamCon.
Note: The data record corresponds to the Stegmann SSI Standard!
Clock
Tp
Data
Tmono
= clock impulse
max. 1MHz to min. 66kHz.
(adjustable through the cable
length)
= Mono flop time 25µs
Encoder
CamCon
+24V DC
0V
Clock +
Clock -
Please note:
Use a screened dual strand connection cable. Do not place
the cable parallel to a high voltage cable. If possible, lay the
screening down on both sides.
Data +
Data -
4.2.2. Parallel measuring system input
Systems with parallel 24V data leads, e.g. single turn - angle encoder or via a transformer with parallel
data output.
In this instance a gray or binary encoded value is attached to the free inputs of the CamCon and this
will be read as actual value. Since the connection cable are quite expensive and the EMV compatibility is limited, this interface type is rarely used in industry nowadays.
Note:
Since the outputs are partly switched parallel to the inputs in CamCon DC16, DC115,
DC300 and CamCon 1756-DICAM, these must not be programmed under any
circumstances and this reduces the number of available outputs.
Warning:
Reading a binary encoded value into the CamCon is only permitted after consultation with
the Service department of the company Digitronic.
,Version from: Aug. 04
Page: 20
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
4.2.3. Incremental measuring system input
Systems with 90° phase shift signals such as turning angle encoders, glass measuring rods or flow
measuring devices.
At the present time incremental measuring inputs for the CamCon DC16/50/51/115/300 and DC1756
are available as an option. We differentiate between three signal levels:
Note:
24V PNP Signal inputs
5V RS422 Signal inputs
Hiperface Signal inputs
(Order number Option: J)
(Order number Option: I)
(Order number Option: H)
For the CamCon DC16 and DC300 only the version with 24V PNP signal is available. For
the CamCon 1756-DICAM the version with 24V PNP signal and Hiperface Signal is
available. If a different signal level is necessary, this can be converted externally with the
INCDRV converter.
In all cases the CamCon supplies the measuring system with 24Volt/DC or in CamCon DC115
optionally with 5 or 24Volt/DC. As a counting signal the measuring system gives out two impulses at a
time shifted by 90° (A + B). These are counted in the CamCon and are evaluated as position values. In
addition, for each rotation another zero impulse (Clear 1) is given out for synchronisation purposes. In
order to stop synchronisation (zero setting) of the counter, a further clear signal (Clear 2) is available
on the CamCon.
The signals Clear 1 and Clear 2 are to standard AND linked and can be
changed in their function with the software. See Chapter "7.4.1.6.3.
Incremental - measuring system" on page 49
A Imp.
B Imp.
Clear 1
4.2.3.1. Incremental measuring system input with 5V RS422 level
Clear 2
If the 5V RS422 system is used, all signals of the measuring
system input must be active, otherwise the input conditions are
undefined. If no signal is available for one of the two Clear
inputs, then this input must be switched to mass on the (+)
signal in order to switch the input to low. The inputs of the
measuring system can be activated with a maximum voltage of
5V. Please pay attention to the power supply of the angle
encoder which can be 5Volt as well as 24Volt. Only the CamCon
DC115 can at present provide a voltage of 5Volt for the supply of
the angle encoder.
4.2.3.2. Incremental measuring system input with 24V PNP level
If a 24V PNP signal is used for data input, then only the (+)
signals of the inputs may be connected. The (-) signals must
stay inactive in this case. The connection of such a measuring
system requires a change of the interal switch system and must
therefore be stated on the order form.
Note:
At the incremental input of the CamCon DC16,
DC300 and DC1756 no (-) signals are available.
,Version from: Aug. 04
Page: 21
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
4.2.3.3. Incremental Hiperface measuring system input with SINCOS level
The Hiperface measuring system is a feedback system for servo-motors of the company Stegmann.
It is a mixed system and consists of an absolute measuring system and an incremental measuring
system. The absolute measuring system sends its values via RS485 interface to the counter. The
incremental measuring system works with analog sine - and cosine interface with a resolution of 512 or
1024 impulses per revolution.
The CamCon with the Hiperface signal input
(option: H) reads only the incremental sine - and
cosine signal. The signals are converted and
counted in the CamCon into normal incremental
measuring system signals.
CamCon
Since the absolute measuring system of the
Hiperface interface is not used and no clear signals are available, the CamCon must be
initialized after each restart.
controller
SINCOS
This must be done by the preset input of the
CamCon. See for this to chapter 7.4.2.4. Actual
position preset on page 56.
Note:
The maximum number of
revolutions per minute is 3000 min-1 with 512 Impulse per revolution.
The maximum number of revolutions per minute is 1500 min-1 with 1024 Impulse per
revolution.
4.2.4. Analog measuring system input
These are systems which receive their actual value through conversion of current or voltage signal,
such as temperature or pressure sensors.
For the recording of analog signals the analog to SSI conversion module AWA/SSI in 8 and 12 bit
resolution is available for the CamCon. This module is connected to the SSI of the CamCon and is
switched ON through the selection of the analog measuring system in the menu ”Measuring system”.
,Version from: Aug. 04
Page: 22
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
4.2.5. PLL measuring system input
Systems with Phase - Lock - Loop data recording. In these systems the actual value is found through
interpolation of initiator impulses. This measuring system is applied to machines with constant speed
and with a cyclic pulse.
= Initiator impulse
= Found actual value
The Initiator can be connected to any free input of the CamCon.
Note:
For CamCon DC115 a special input is available on the 25pol. SUB-D plug.
See also chapter "7.4.1.6.5. PLL measuring system" on page 51.
4.2.6. Timer as a measuring system
Systems which are controlled by elapsed time. In this case the CamCon makes a time available with a
time basis of minimum 1 ms as actual value. Through laying on of input signals it is possible to
influence the elapsed time. This measuring system is applied to machines with a fixed time scanner as
a control feature, e.g. washing machines.
See also chapter "7.4.1.6.6. Timer way simulation" on page 51.
4.2.7. RS232 as a measuring system
Systems, receiving their actual position through the RS232 interface, e.g. for a junction of a Stegmann
POMUX linear scale to a RS232 data output.
Warning
The activation of this measuring system blocks the RS232 interface for
programming. This measuring system is only reasonable with a CamCon
DC50/51.
,Version from: Aug. 04
Page: 23
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
4.3. The outputs
The CamCon has, concerning each upgrading level, up to 32 outputs and with extreme extension (e.g.
CamCon DC16/IO, DAC16 or DC91/IO) up to 200 short circuit-proof outputs. They deliver 24Volt high
active signals and are not potentially free towards the CPU. The outputs 1 to 16, as well as 17 to 32 of
the unit have to be supplied with 24Volt , because the power supply of the outputs has been separated
in order to achieve a better power distribution.
4.3.1. The 40mA outputs (only CamCon device with aluminium back wall)
If all outputs are activated, not more than 40 mA permanent current in the complete temperature range
should be extracted per output, else the unit will deactivate with an error message. If a higher starting
performance is required, one has to know that the outputs are combined in 4 groups, each group
consisting of 8 outputs. Within each group, 480 mA permanent current at a surrounding temperature of
50°C, and at a surrounding temperature of 25°C even 700mA permanent current is available. This
permanent current can be dirtributed freely within a group, as long as the single output current of 300
mA is not overshot (see chapter "7.4.6.2. Setting the outputs" on page 63).
4.3.2. The 500mA outputs
At a surrounding temperature of 25°C even 500mA permanent current is available for each output. If
your outputs are overloaded or short-circuited the unit will deactivate with an "out-err" message
(see chapter "7.4.6.2. Setting the outputs" on page 63).
Attention: For inductive loads the inductances have to be tripped with a freewheeling
diode.
4.4. The inputs
The CamCon has, concerning each upgrading level, up to 16 inputs and with extreme extension up to
200 inputs. These inputs work with high externally active 24Volt signals and are not potentially free
towards the CPU.
The input wiring:
The input resistance
is about 5.7 KOhm.
The inputs of the CamCon have not been covered with functions by the factory. The user would have
to do this himself in the process of setting system data of the CamCon depending on his requirements.
See chapter "7.4.6. System upgrading" on page 63, chapter "7.4.1. Measuring system" on page 45,
chapter "7.4.6.7. Setting the external program selection" on page 64 and chapter "7.4.6.4. Setting the
keyboard lock" on page 63.
4.5. Precautionary measures for welding work
Attention: For the duration of welding operations carried out at the machine, the
connecting wires concerning the data exchange from the measuring system to
the CamCon and the power supply as well as the grounding connections and
inputs and outputs have to be separated from the CamCon.
,Version from: Aug. 04
Page: 24
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
5. Outline of the operator terminal
5.1. Frontview CamCon
5.2. The liquid crystal display (LCD)
The display unit of the CamCon 50 contains a graphical LCD with 128x64 picture elements. For the
visual user prompting, all menus concerning the programming of the unit, state and error messages of
the outputs, as well as the current position and speed, are represented here. The contrast can be
adjusted to the current surrounding temperature with the keyboard.
5.3. Contrast setting
You can increase or decrease the contrast of the LCD in this display mode with the
Keeping these keys pressed continues the change of contrast.
and
keys.
5.4. The keyboard
The plastic foil keyboard of the CamCon is non-sensitive towards dirt and is solvent resisting. The keys
have a noticable action point for the tactile feedback, as well as an acoustic input acknowledgement
(see chapter 7.4.6.4.7.4.6.4. Setting the keyboard lock on page 63).
,Version from: Aug. 04
Page: 25
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
5.5. Outline of key functions
cursor down
cursor up
cursor to the left, shifting cams
cursor to the right, shifting cams
choose cam activation point, character selection during text input,
(or PC 'PageUp' key)
choose cam deactivation point, character selection during text input
(or PC 'PageDown' key)
input of cams, special measuring systems, character during text input
place holder for display formats, reset during error messages, special functions
Escape: leaving the current menu, returning to the next higher menu
deletion of cams, outputs, programs and single characters during text input
deletion of single characters during text input
confirm input and save data
changes the algebraic sign during data input
comma
...
numeric keys for data input
5.6. Menu selection
You can select a desired menu by pressing the corresponding numeric key or by moving the cursor
(the black beam) on the menu name with keys
and
and pressing the
key.
5.7. Selection of a menu point
The input in the single menus issubdevided into menu points. These are active (or selected), if the
display is inverted. The selection of these menu points is made with keys
,
,
and
and a
confirmation of your choice with the
key. You can always cancel an input by pressing the
key. If
you pressed a wrong key, the unit shows a hint of the keys you can use in this menu and their
functions.
,Version from: Aug. 04
Page: 26
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
5.8. Text input
With menu points, in which texts have to be implemented, the
the
and
using the
and
keys function together with
keys like a coordinate control. You select the desired position for the first character,
and
keys. Then you can choose the character with the
and
keys, by going up
and down through the alphabet or the ASCII characters. If you move the cursor to the right with the
key, character entered prior to this will appear in the new position of the cursor, simplifying making
repeated inputs of the same character.
If you have made an error you can go back to the wrong character to correct it, using the
key or the
key. This will cause the other characters to become erased. To abandon the input press the
key.
Attention: The software for the text input at the CamCon has changed since EPROMS of 1/97. The
selection of desired characters is now realized with keys
and
. With keys
and
you can now position the cursor anywhere in the previously entered text. You can
overwrite characters, insert characters by pressing the
keys
Note:
or
key or delete characters with
.
The text input is also possible directly via PC.
,Version from: Aug. 04
Page: 27
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
6. Commissioning
Before switching the device on for the first time, please check its wiring (see chapter 4.1. Pin allocation
on page 15).
Attention: With induced loads the outputs have to be switched with a freewheeling
diode. Covers or inductivities very close to the device inside the
switchboard have to be switched with a deletion unit as do those that are
wired to or influence the wiring of the device.
After being switched on the CamCon will generate a short tone. Afterwards it will start the internal
review and the running up of the system (e.g. to generate the proof total of the EEPROM and the
EPROM). This process takes several seconds. After a successful installation of the system, the
standard display (the current program number, the position and the speed, as well as a possible error
message) is displayed. Once the system registers are brought in accord to the measuring system and
it is wired correctly, there should be no further error messages.
After first activating the supply voltage, the program memory is not in a defined state. So when first
using the CamCon unit you have to put a complete deletion into operation as follows:
1.
Press the
key, you leave the standard display
and enter the main menu:
2.
Select the menu point "Unit configuration" , the
request to enter your user code is displayed on the
LCD:
3.
4.
Enter your user code. If you have not programmed
your own key, use the standard key number
"5693"!
Press the
key to confirm your user code. If a false code is entered, "Wrong user code!" is
shown on the display. In this case, press any key, and reenter the code. The display returns to
the main menu after about 30 sec., if no numbers are entered or the input is not confirmed with
the
key.
After the correct user code is entered, the display shows
the configuration menu.
5.
Select the menu point "Format unit" , the following
question is displayed:
6.
Move the cursor to "yes" with the
7.
Press the
,Version from: Aug. 04
key.
key.
Page: 28
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
After about 5 sec. the display returns to the configuration menu. This waiting time depends on the size
of the used EEPROM, since the memory has to be formatted. With the use of a 32k - EEPROM it is
increased to approximately 2 min. After this time the complete deletion is finished. All cams are erased,
all system registers have the standard value.
Now you can begin with the system setting.
To make your device operable, you have to set a minimum number of parameters on your CamCon.
This is the recommended order of the parameterization. You can find the neccessary information in the
corresponding chapters.
1)
2)
3)
4)
System setting, System upgrading
See chapter "7.4.6. System upgrading" on page 63.
System setting, Cable length
See chapter "7.4.4.1. The cable length" on page 59.
System setting, Measuring system
See chapter "7.4.1. Measuring system" on page 45.
Unit configuration, hardware configuration, See chapter "7.5.6. Configure Hardware" on page 75.
If you have adjusted the inputs according to the corresponding chapters, the CamCon is ready and no
more error messages should occur. Of course we recommend to go through the whole system setting
menu to receive a maximum of user ability and comfort.
After the system setting you can begin with the cam programming.
,Version from: Aug. 04
Page: 29
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7. Operation of the CamCon
.
7.1. The main menu
The programming always starts at the main menu. No
matter in which state of programming you are, you can
always reach the main menu by pressing the
(several times, if necessary).
key
By pressing the corresponding number or by selection
with keys
and
and a verification with the
you can enter the submenus.
key,
7.2. The standard display
You reach the submenu for the display for normal operation of the cam controller via the main menu
point "Visual mode" or by pressing the
key (at the main menu).
In the display menu, the active program number, the
relative speed as a bar (e.g. for an analog speed output)
and the current actual position, respectively the absolute
speed (with higher rotational numbers), are displayed.If
the measuring system is put into a slow motion the
respective actual position is shown on the display. With
increasing rotation velocity the device switches at a
defined point (5%) to a display showing the current speed
in the desired representation; a negative direction in the
rotation is shown through a negative sign in front of the
displayed value.
The configuration of the speed display is done in the system setting menu. Here you can e.g. disable
the automatic change of the display, by selecting a certain display type (see chapter "7.4.3. The speed
adjustment" on page 57).
7.2.1. Changing the display
If you want to receive status information of in- and outputs during operation, you can switch through the
several status displays, using keys
inputs and outputs:
and
. The display then shows an outline of operation for
Output display
Input display
As soon as an in- or output activates, its field on the display turns black.
In the lower righthand corner of the display, you can see the current position or the absolute speed at a
faster movement.
,Version from: Aug. 04
Page: 30
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.2.2. Program change
With the CamCon you are capable of storing several programs. To choose one of these programs you
have to be in the standard display. The selection of a desired program is done as follows:
1.
2.
Press the
key, the display shows the request for your user code.
Enter your user code.
3.
Press the
4.
Enter program number with the numeric keys
5.
Press the
key, the cursor goes to the menu field of the program number.
key to complete your input
The CamCon will change programs according to the program selection parameters you entered. If the
process takes longer that one second, the display will blink until the selection is complete see chapter
"7.4.6.8. Setting the program selection mode" on page 64.
7.2.3. Program name
With the CamCon you can assign a text to the stored programs. This is recommended when important
information needs to be linked to the program number (e.g. a toolnumber or the name of a product).
The input of the program name is done as follows:
1.
2.
Press the
key, the display shows the request for your user code
Enter your user code
3.
Press the
key, the cursor goes to the menu field of the program number
4.
Press the
key, the cursor goes to the text input of the program number
Here you can enter a name for your program (see chapter "5.8. Text input" on page 27).
5.
Confirm your input with the
key
The presentation of the program name changes with the length of the input text. 2 lines with 21
characters each or 1 line with 10 characters can be displayed.
,Version from: Aug. 04
Page: 31
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.3. Cam programming
To get to the actual cam programming select "Cam programming" in the main menu. The display
switches to the programming menu:
The upper part shows the current actual position, the switched state of the selected output and the
chosen program. The lower part displays an output with programmed cams and their activation and
their deactivation points. If no input is made within two minutes the CamCon automatically returns to
the main menu for reasons of safety.
7.3.1. Output selection for programming
You can select the desired output by pressing the
By pressing the
and
keys.
key you reach the direct input of the output number.
With the numeric keys you can select the number of the output you want to select. Confirm your
selection with the
key.
,Version from: Aug. 04
Page: 32
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.3.2. Program selection for programming
You reach the input of the output number by pressing the
and enter the program selection for the programming.
key. You skip this by pressing the
key
Enter the number of the desired program by using the numeric keys. Confirm your input with the
key.
A change in the program number does not lead to a change in the momentarily active cam
program. This means: You can program a program while another program operates the
outputs.
7.3.3. Programming the delay time/speed compensation
You reach the input of the output number by pressing the
and enter the delay time you want to compensate.
key. You skip this by pressing the
key
With the numeric keys you can enter the delay time that you need to compesate.
By pressing the
key while entering, the effects of the speed compensation for the switch-on- and
switch-off-point will be switched separately and the second delay time value can be fed in.
This seperated speed compensation can be deleted by pressing
time value.
while entering the second delay
Attention:
If the offswitchpoint overtakes the onswitchpoint at rising speed, the result will be a non-defined signal.
By pressing the
key with the input you can limit the effect of the delay time to the program you are
programming (private). A renewed pressing of the
for this program.
Confirm your input by pressing the
key takes on the standard speed compensation
key.
References to the way speed compensation works can be found in chapter "2.1. Speed
Compensation" on page 9.
,Version from: Aug. 04
Page: 33
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.3.4. Programing Time-Cams
By pressing
you get to enter the starting number, which can be adopted by confirming with key
. After that, you are put forward to entering the delay time.
Attention: When programing a Cam, the specific output must have a switched speed compensation.
Also see chapter "7.4.6.3. Setting the outputs with speed compensation" on page 63.
Using the numeric keys you can enter the delay time. Press while entering followed by pressing to
switch on your way-Cam, so that you are able to enter the switching time in steps of 0.1 ms.
Pressing
while entering the switching time will switch of the Cam.
Attention:
If the next Cam switching point reaches a Cam that is not yet switched off, both Cams will be summed
up as one.
Pressing
while entering delay time or switching-time values can limit the efffects of these values
on the program that is worked on (private). A second
key will switch off the private input. This
function can be switched on or off separately for delay- and switching time.
A
key will confirm these values and quit the input-section.
,Version from: Aug. 04
Page: 34
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.3.5. Programming the output name
You reach the input of the output number by pressing the
and enter the input of the output name of this output.
key. You skip this by pressing the
key
Here you can enter the output name via text input see chapter "5.8. Text input" on page 27.
7.3.6. Cam Input
By pressing the
key you start the input of a cam. On the display the field for the cam activation
point (left bar) is underlayed in black, while a stylized cam blinks in the range of the two bars. With the
numeric keys you enter the position for the cam activation point.
After you confirm your selection with the
key, the field for the cam deactivation point is underlayed
in black. Simultaneously, the dropping flank of the stylized cam starts to blink.
Enter the value for the cam deactivation point with the numeric keys and finish your input with the
pressing of the
key.
Remember:
The maximum expansion of a cam can never reach a full rotation. For the
programming of such a cam you have to program a security output (see chapter
"7.4.5. The special outputs" on page 59.
,Version from: Aug. 04
Page: 35
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.3.7. Adding cams
In case you want to program additional cams on this output, you have to use the
press this key the following is displayed on the display:
key. When you
Here you can enter the positions for the activation and the deactivation point for the cam, as is
described in the chapter "7.3.6. Cam Input". If you enter a cam that overlaps with an already existing
cam, you create a single, greater cam.
Example:
The previously configured cam lies between 50 and 120 degrees. If you now create a new
cam between 90 and 180 degrees, these two cams are combined into a new cam from 50
to 180 degrees.
7.3.8. Cam Teach - In
If you are in an input field of an activation or deactivation point during cam programming, you can
assume the current actual position for the field by pressing the
and brought up to date until the
input.
,
,
or
key. The actual position is displayed
key is pressed to confirm the value or to abort the
7.3.9. Cam Search
With the
and
keys you can call up and control the programmed cams. With each activation a
single cam is displayed, and its neighbouring cams are shown as their flanks on the edges of the
display.
The increasing course of the cam curvature on the right edge of the display points to another cam that
is positioned between the cam deactivation point (180°) and the higher border of the measurement
range (e.g.:359°). The left flank hints to the presence of additional cams between the cam activation
point (45°) and the lower border of the measurement range (e.g.:0°).
With the
and
keys you can determine wether there are other programmed cams.
,Version from: Aug. 04
Page: 36
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.3.10. Cam deletion
If you want to completely erase a cam, select the cam using the
key, causing the following question to be displayed:
To delete the cam, move the cursor to "yes" with the
choice.
and
key, and press the
keys and press the
key to confirm your
7.3.11. Output (cam track) deletion
If you want to completely erase an output (cam track), you have to press the
of the output number.
key to enter the input
Now you can enter the number of the output you want to delete with the numeric keys. Press the
key and the following question is displayed:
Move the cursor to "yes" with the
key and press the
key to confirm your input.
,Version from: Aug. 04
Page: 37
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.3.12. Copying programmed outputs (cam tracks)
With the CamCon you have the option to copy all the cams you have programmed on one output to
additional outputs. First press the
key to enter the input of the output number. Select the output that
you want to copy to the previous selected output with the numeric keys. Press the
copying process. The following question is displayed:
key to start the
Move the cursor to "yes" with the
key and press the
key to confirm your input.
This starts the copying process. After a short while the new output will appear on the display.
7.3.13. Shifting cam tracks
With the CamCon you have the option to shift all the programmed cams of one output, using the
and the
Press the
key.
or the
If you now press the
key to enter the input of the activation or the deactivation point.
key or the
key, all the cams of this output are shifted by one increment. In
this case the cams are directly taken over into the memory without the use of the
before). The shifting process is ended by pressing either the
,Version from: Aug. 04
key or the
key (unlike
key.
Page: 38
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.3.14. Deleting programs
If you want to erase a whole program, you have to press the
number. Skip it by pressing the
key to enter the input of the output
key, and you enter the program selection for programming.
Enter the number of the program that you want to delete with the numeric keys. Press
and the
display shows the security precaution question for the deletion of programs. Move the cursor to "yes"
with the
key, and press the
key to delete the program.
7.3.15. Copying programs
With the CamCon you also copy whole programs. This is done as follows:
key, the cursor moves to the input of the output number.
1.
Press the
2.
3.
Press the
key, the cursor moves to the input of the program number.
Select the program you want to copy using the numeric keys.
4.
Press the
key to confirm your selection.
5.
Press the
key, the cursor moves to the input of the output number.
6.
7.
Press the
key, the cursor moves to the input of the program number.
Using the numeric keys, select the program onto which you want to copy the previously selected
program.
8.
Press the
9.
key, to start the copying process. The display shows the question:
Move the cursor to "yes" with the
key and press the
key to confirm your input.
This finally initializes the copying process, and after a short while the new program appears on the
display.
,Version from: Aug. 04
Page: 39
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.3.16. Examples for cam programming
.
7.3.16.1. First cam programming
Task: After a complete deletion of the program memory and a successful initialization of the system, a
cam shall be programmed for output 4 from 100° to 200° with a speed compensation of 100ms
Solution:
1.
Choose the main menu point "Programming".
2.
Enter your user code and press the
the programming menu displayed.
3.
Press the
4.
key, the cursor moves to the field for
Press the
speed compensation.
Enter the value "1000" with the numeric keys.
5.
6.
7.
8.
9.
key, to have
key and enter "4".
Press the
key to enter the cam activation point.
The cursor moves to the input field for the cam
activation point. Simultaneously, a stylized cam
starts blinking.
Enter the value "100" for the cam activation point
with the numeric keys.
Press the
key. The cursor moves to the input
field for the cam deactivation point.
Enter the value "200" for the cam deactivation point
with the numeric keys.
10. Press the
key to confirm your input. The first
cam is now programmed.
11. You can leave this menu any time by pressing the
key.
,Version from: Aug. 04
Page: 40
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.3.16.2. Programming additional cams on an output
Task: Program an additional cam from 300° to 330° in program 0, on output 4 with the cam from 100°
to 200°.
Solution
1.
Select the menu point "programming" in the main
menu.
2.
Enter your user code and press the
programming menu is displayed:
3.
Select output 4 with the
"4" and press the
4.
5.
6.
7.
8.
key. The
key or press
, enter
key again.
Press the
key to enter the cam activation point
for an additional cam. The cursor moves to the input
field for the cam activation point; a stylized cam
starts to blink simultaneously.
Enter the value "300" for the cam activation point by
using the numeric keys.
Press the
or the
key. The cursor moves to
the input field for the cam deactivation point.
Enter the value "330" for the cam deactivation point
by using the numeric keys.
Press the
key to confirm your input. The second
cam is programmed.
The display shows the newly programmed cam as well as the cam between 100° and 200° as a flank
on the left edge of the display.
9.
You can leave this menu at any time by pressing the
key.
,Version from: Aug. 04
Page: 41
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.3.16.3. Deletion of a particular cam
Task: In program 0 the inserted cam between 300° and 330° shall be erased.
Solution:
1.
Select the menu point "cam programming" in the
main menu.
2.
Enter your user code and press the
programming menu is displayed.
3.
Select output 4 with the
"4" and press the
key or press
, enter
key again.
4.
Select the inserted cam with the
5.
Press the
question:
key.
key. The display shows the following
6.
Using the
key, move the cursor to "yes".
7.
Press the
key to confirm your input. The cam between 300° and 330° is erased.
,Version from: Aug. 04
key. The
Page: 42
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.3.17. Programming analog cams
If your CamCon is equipped with analog outputs, and you have activated the option of analog cams
(see chapter "7.4.5.7. Configuration of the analog cams" on page 61), the last "normal" output will be
displayed as the first analog output after pressing the
you can choose the next output number by pressing the
+
. If several analog outputs are programmed,
key.
=>
The output numbers of the analog cam outputs are always added to the numbers of "normal" outputs
and this number can be selected directly from the programming menu. If you have configured e.g. 32
cam outputs, the number of the first analog cam starts at the output 33. The output number of the
analog cam changes automatically when you change the number of "normal" outputs (see chapter
"7.4.6.2. Setting the outputs" on page 63).
The programming of the analog cam is mostly done as described in the chapters for "normal" cam
programming (see chapter "7.3. Cam programming"). For analog outputs, you do not program a
position as a deactivation point, but an analog value. If several such values are programmed at
different positions and the measuring system starts to move, CamCon controlls the analog output in
such a fashion, that a curve is done, corresponding with the drawing below.
without interpolation
with interpolation
+10V
0°
+10V
90°
-10V
180°
270°
360°
0°
90°
180°
270°
360°
-10V
Through interpolation of the definition points, CamCon can adjust the values and present a curve,
corresponding to the above right drawing.
,Version from: Aug. 04
Page: 43
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.3.17.1. Creating the first analog cam
To program your first analog cam, choose the program and the desired output for programming (see
chapters: "7.3.2. Program selection for programming" and "7.3.1. Output selection for programming").
Press the
key and enter the position value for the first definition point. Now press the
analog value and confirm your input with the
Note:
, enter the
key.
As long as only one cam is programmed on a cam track, the programmed analog value is
emitted for the whole way of the measuring system.
7.3.17.2. Adding an analog cam
To add another definition point, choose a desired output, press the
value. Press the key
key and enter a new position
, enter the analog value and confirm your input with the
key.
Further cams are added with the same procedure.
7.3.17.3. Changing the analog cam
To change or delete an analog cam, proceed as described in chapters "7.3.9. Cam Search", "7.3.10.
Cam deletion" and "7.3.11. Output (cam track) deletion".
Note:
The programming of a delay time, the copying of an analog cam track and the shifting of
the complete cam track is not possible at the time.
,Version from: Aug. 04
Page: 44
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.4. Unit configuration (system setting)
Before you are able to use this device, you have to give
it all the information about the parameters of your
measuring system. Select the menu point "System
setting" in the main menu. The display shows the
system setting menu:
7.4.1. Measuring system
When you select the menu point "Measuring system",
the display changes to the measuring system menu:
Here you can configure the measuring system, the
resolution, the electronic gear, the actual position
hysteresis, the rotation direction and the display format
of the actual position, as well as a special measuring
system. Additionally, the menu point "Position:"
always shows the actual position of the CamCon. See
also chapter "4.2. The measuring system" on page 20.
7.4.1.1. The standard measuring systems
The display gives the resolution of the measuring
system in steps per rotation. Generally the CamCon
works with a rotation angle coder that has a resolution
of 360 steps per rotation. In this case a change in the
input value is superfluous. Otherwise the CamCon can
be adjusted to the measuring system with the
and
keys. You can choose between the following
predefined resolutions, that are all in accordance with
common rotation encoders: 256, 360, 512, 1000, 1024,
2048, 4096 and 8192 steps. Should you not be able to set values in higher resolution ranges, it is
because there is not enough memory available. If this is the case you have to extend the memory of
the device. Also, you can configure two analog SSI changer modules, AWA/SSI/8 and AWA/SSI/12, for
the gathering of analog signals. These modules are connected to the SSI port of the CamCon.
Note:
Should you not be able to set values in higher resolution ranges, it is because there is not
enough memory available. You will need to upgrade the memory of your device. See also
chapter "12. Calculation the RAM storage-requirement for" on page 85.
7.4.1.2. The actual position hysteresis
At the menu point "Hyst." you enter the actual position
hysteresis.
This value is needed to suppress the flashing of the
outputs during uneven data gathering. The exact value
can only be determined through experiments, though it
should be as small as possible or always "0". The
hysteresis can be between 0 and 1/4th of the total
resolution, but can never exceed 255 impulses.
,Version from: Aug. 04
Page: 45
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.4.1.3. Controlling the measuring system
The option "Vmax" of the menu enables entering the tolerated steps per cycle of the actual value..
This enables controlling a measure-system.
The required value is calculated of the CamCon's actual cycle-time, the measuring system's physical
resolution und the device's Speed.
Note:
The resolution needs to be a physical measure, e.g. if for a measuring system 4096
Impulses are calculated to 3600 by a (3600/4096)gear, the resolution must be set to 4096.
Example: Cycle time = 0.5ms / resolution = 360 / speed of machine = 180 min -1.
Value =
resolution * plant speed
* Cycle time + margin
60 * 1000
360 * 180
60 * 1000 * 0.5 + 5 = 5.54 ≈ 6
The result is rounded and filled in "Vmax"
If the CamCon detects a step of more than 6 impulses at the actual value an error report "Ist-Err:5" is
shown.
If a zero is filled in here, the controll is deactivated, and a maximum of 9999 is possible.
,Version from: Aug. 04
Page: 46
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.4.1.4. The electronic gear
In the menu point "Measuring system" a factor for a measuring range transformation can be entered.
Through this the physical measuring range e.g. of a rotation encoder is transformed into a new, for the
user effective visible measuring range. Generally this transformation has the relation 1:1. The first
value represents the multiplier of the actual position, while the second value stands for the divisor
through which the result of the previous multiplication is divided. The result of this operation is the
display value. A negative value in the field of the multiplier changes the direction of the rotation of the
measuring system. To switch the algebraic sign press the
Example:
key during the input of the multiplier.
At a full rotation of a rotation encoder with 360 steps per rotation a machine proceeds for
1000mm.
If the display of the position is to be shown is mm rather than in angular lines, you have
reset the gear with the factor 1000 / 360. The display will no longer change in single steps,
since the resolution remains unaffected.
If you choose e.g. 100 / 360, the actual position is calculated down to a proceeding range
of 100. The position display is carried out in cm, but a floating point representation is not
possible.
7.4.1.4.1. Electronically changing the rotation direction
The direction of the rotation of the measuring system is
set at the multiplier of the electronic gear by changing
its algebraic sign. Press the
key during the input of
the multiplier. See the chapter "7.4.1.4. The electronic
gear".
7.4.1.5. The display format of the actual position
In this menu point you can set the format for the display of the actual position.
The three # are the place holders for the number value
of the display. You can enter additional comments and
the unit of the measured value, e.g. mm, cm or inch
with linear systems. See chapter "5.8. Text input" on
page 27. If you want to display a decimal point, you can
insert one between the place holders (e.g.: ###.#mm).
,Version from: Aug. 04
Page: 47
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.4.1.6. Configuration of a special measuring system
You have the possibility with CamCon to configure a
special measuring system, according to the following
steps:
1.
2.
To configure the special measuring system press
the
key. The menu for the input of a new
measuring system appears on the the display.
Enter the measuring system description. See
chapter "5.8. Text input" on page 27.
3.
4.
Presss the
key to end the input of the first line. The cursor moves to the next line.
Enter additional text (if desired).
5.
Press the
system".
6.
Select the type of the measuring system with the
key to end the text input. The cursor moves to the next menu point, "Measuring
and
keys.
7.
Press the
key to confirm your input. Now the menu for the measuring system chosen by
you is created. The following chapters discribe the different measuring systems and their settings.
7.4.1.6.1. SSI - measuring system
If you selected "SSI" for your special measuring system
in the measuring system input, the following menu is
created:
1.
2.
3.
4.
5
Enter the bit number of the resolution of the SSI
measuring system
A resolution of e.g. 500 impulses corresponds with 9
bits.
Now enter the position of the lowest-situated bit
(LSB).
In our example the LSB would be on 9th position. You can get more specific information from the
manufacturer of your measuring system.
Now enter the cut of the measuring system code.
In our example this would be ( 512 - 500 ) / 2 = 6.
Finally you have to enter the position of the SSI - errorbit of the measuring system. With standard
rotation encoders of the firm Stegmann this position is 14. Always transfer a 0 to this position.
Press the
key to confirm your inputs and exit this menu.
Attention: The position of the data bits can be seen in the graphic in the upper part of the display.
You can determine the positions of the LSB, HSB and errorbits quite easily by moving the
measuring system.
,Version from: Aug. 04
Page: 48
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.4.1.6.2. Parallel - Gray measuring system
If you selected "PARAL." for your special measuring
system in the measuring system input, the following
menu is created:
1.
2.
3.
Enter the resolution of the parallel gray measuring
system.
Here e.g. 500 impulses.
Now declare the input of the lowest-situated bit
(LSB).
In our example the position of the LSB would be at input 7. With a resolution of 500 impulses 9
bits of resolution are needed. The CamCon automatically determines the position of the remaining
inputs once it knows the position of the LSB; they are determined in increasing order. In our
example inputs 7 to 16 would be allocated with the bits of the rotation encoder.
With Mode you can choose the encoding of an parallel meassure system by pressing
you can choose betweenGray = Gracode and Bin. = Binarycode zur Verfügung.
and
:
Attention: Parallel binary encodings shall only be used as an exception. Please implicitly contact
your custoimers service.
4.
Press the
key to confirm your inputs and exit this menu.
7.4.1.6.3. Incremental - measuring system
If you selected "INC" for your special measuring system in
the measuring system input, the following menu is
created:
1.
2.
3.
Enter the value of the prescaler (predivisor) with the
and
keys. The prescaler divides or multiplies
the incoming impulses from the measuring system
with the defined value. The following scalers can be
entered: "*4", "*2", "*1", "/2", "/4", "/8", "/16", "/32",
"/64", "/128", "/256", "/512".
Here the prescaler is set to "*4". This means that a measuring system with a resolution of 500
impulses supplies the device with 2000 impulses.
Now you enter in the field of the resolution the maximum number of needed impulses. This value
is the maximum resolution, that can be evaluated by the CamCon. If more impulses than this
maximum resolution are counted, the CamCon reports the error message "Pos Err:3". In this
case the maximum resolution has to be reset with a higher value or the actual position has to be
set to zero through a clear signal.
In the field "Clear mode" you set the functions for the two extra inputs C1 and C2 with the
and
the
key. Here you have the choice between eight possible functions.
"C1 & C2"
If input C1 is high and C2 is high, the counter is set to zero.
"/C1 & C2"
If input C1 is low and C2 is high, the counter is set to zero.
"C1 & /C2"
If input C1 is high and C2 is low, the counter is set to zero.
"/C1 & /C2" If input C1 is low and C2 is low, the counter is set to zero.
"C1 : W"
If input C1 is high, the counter is set to zero.
If input C2 is high, the impulses of the measuring system are no longer counted.
"/C1 : W"
If input C1 is low, the counter is set to zero.
If input C2 is high, the impulses of the measuring system are no longer counted.
"C1 : /W"
If input C1 is high, the counter is set to zero.
If input C2 is low, the impulses of the measuring system are no longer counted.
"/C1 : /W".
If input C1 is low, the counter is set to zero.
If input C2 is low, the impulses of the measuring system are no longer counted
(W = Wait).
,Version from: Aug. 04
Page: 49
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
"C1 or áC2" Counter is set to 0, If input C1 is high or a signal at input C2 changes from low to
high.
"C1 or âC2". Counter is set to 0, If input C1 is high or a signal at input C2 changes from high to
low.
7.4.1.6.4. Multiturn measuring system with electronic gear
If you selected "MULTI" for your special measuring
system in the measuring system input, the following
menu is created:
This measuring system is needed when using a multiturn
encoder with a non-binary number of rotations.
Example 1: You have a rotation plate with an electronic gear rate of 3 to 1, i.e. the encoder rotates 3
times for every rotation of the plate. These three rotations correspond with 360 impulses (360
degrees). You need to make the following inputs:
1.
2.
3.
4.
Enter the total resolution needed.
Here 360 impulses (360 degrees).
Enter the total number of rotations.
Here 3 turns.
Enter the divisor for uneven translation rates.
Here 1.
Press the
the menu.
key to confirm your inputs and leave
Example 2: You have a rotation plate with an electronic gear rate of 12.5 to 1, whereas the encoder
turns 12.5 times for every rotation of the plate. These 12.5 rotations correspond with 3600 impulses
(360.0 degrees). The following inputs are necessary:
1.
2.
3.
4.
Enter the total resolution needed.
Here 3600 impulses (360.0 degrees).
Enter the total number of rotations.
Here 25 turns.
Enter the divisor for uneven translation rates.
Here 2.
Press the
the menu.
key to confirm your inputs and leave
Attention: This measuring system only works in connection with multiturn encoders with a resolution
of 4096 x 4096 impulses (Type: AAG66107 or AAG626).
Note:
With this measuring system the encoder may not be moved more than 512 rotations in a
cold state.
,Version from: Aug. 04
Page: 50
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.4.1.6.5. PLL measuring system
If you selected "PLL" for your special measuring system
in the measuring system input, the following menu is
created:
The PLL measuring system determines the way out of
temporal interpolation of a measuring impulse. If you e.g.
have installed an initiator on a rotation plate and want to
determine the current position at a constant velocity
without having to install another measuring system, the
PLL measuring system is the right choice.
1.
2.
3.
4.
5.
6.
Enter the number of steps from initiator impulse to initiator impulse.
Now enter the input of the initiator impulse.
Now you have to enter the number of initiator impulses per total rotation.
Select the input for the clear impulse.
With the PLL measuring system you have the possibility to incase several initiators per total
rotation. To receive a zero point you need a zero initiator that can be hooked up to the selected
input. If you do not want to use a zero initiator, just enter a "0" here.
Then you enter the synchronous window.
If a step error is determined that is larger than the set value, the system enters the asynchronous
mode.
Now you have to enter the output for the synchronous window that signalizes the synchronous
state. If you do not want such an output, just enter a "0" in this line. This output becomes active
after the PLL measuring system has been in the synchronous mode for 16 cycles.
Press the
key to confirm your inputs and exit this menu.
7.4.1.6.6. Timer way simulation (time emitter)
The timer way simulation makes it possible to generate
ways (or time related actual positions) time based and
without the use of a measuring system. The cam switch
unit then behaves similar to the control of a washing
machine. For this option you have to select "TIMER" in
the special measuring system menu and the following
system is set up:
1.
2.
3.
4.
5
First enter the time between the steps. The finest
resolution of the CamCon is 1ms.
In our example we chose 20 ms.
Now enter the total number of steps.
We chose 100 steps for our example, so the whole process will be repeated after 2 seconds (20
ms x 100 steps = 2 seconds).
After this you have to enter the input for the stop signal.
This will enable the time emitter system. A high signal at this input releases the timer, and the
timer is stopped by a low signal. If you do not want a stop input just enter a "0".
Finally you have to enter the input for the clear signal.
With this signal the time emitter system can be reset to 0. A high signal at this output causes the
timer to remain at "0". If you do not want a clear input, just enter a "0" in the corresponding line.
Press the
key to confirm your inputs and exit this menu.
,Version from: Aug. 04
Page: 51
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.4.1.6.7. RS232 measuring system
The RS232 way gathering is needed, if the measuring system used by you does not contain any of the
interfaces described in the previous chapters.
To use this system you have to select "RS232" in the
special measuring system menu and the following menu
is set up:
1.
First you have to enter the baud rate using the
and
2.
3.
4.
5.
keys.
The data transfer protocol can be set with the
key and the
key as before.
At the moment only the data transfer protocol of a Stegmann Pomux 203BCD is available.
The resolution gives the value in which the actual position of the measuring system is moving.
The prescaler (predivisor) divides the resolution to enable the setting of the measuring system in
devices with lower memory.
Press the
key to confirm your inputs and exit this menu.
Attention: This measuring system may only be used on a CamCon DC50/51, since it
blocks the serial interface, making the programming via a PC or a
terminal impossible!
7.4.1.6.8. AG615 - Single - Multiturn - Measuring system
Having selected "AG615" in the special measuring
system-menu, the following menu appears.
The AG615 - Single - Multiturn - measuring system
creates a multiturn- i.e. ultility measuring system out of an
AAG615 - 8192 Singleturn - measuring system.
As a result several rotations i.e, turns at the Single Multiturn - Measuring systemCamCon per rotation of the
AG615 appear.
1.
2.
Give in the number of rotations i.e. turns that shall be created at the CamCon first (e.g. 3).
Then enter the resolution that the CamCon shall display or process per turn (e.g. 360).
3.
Confirm your inputs using the
key and leave the menu.
Excample: For a value of 3 * 360 the CamCon will count thrice from 0 to 359 if the AAG615 encoder
does one rotation along the shaft.
,Version from: Aug. 04
Page: 52
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.4.1.6.9. SIM - measuring system simulator
Having selected "SIM" in the measuring system menu,
the following menu appears:
The SIM - measuring system - simulator enables
crearting ways or time actual values without measuring
system, i.e. on time-basis. On the contrary to timer measuring systems a higher speed is possible.
1.
2.
3.
4.
5.
First enter the speed i.e. number of impulses per
second (e.g. 16384).
Now enter the complete number of steps (e.g. 8192).
Now select an out put for the "Stop" signal.
Thereby, the simulator may be enabled. A high signal at this input sets the simulator to run, a low
signal stops the smultor. If you do not want an Stop-input, simply enter a "0" here.
Finally enter the clear signal's input.
With this function, you are able to enable the simulator. A "high" signal at this input leaves the
simulator at "0". If you do not want a clear-input, simply enter a "0" here.
Use the
Example:
key to confirm youre inputs and leave the menu.
With a resolution of 8192 and a speed of 16384 impulses per second a simulated speed
of 120 revolutions per minute is set.
7.4.1.6.10. HIPER i.e. incremental - measuring system with Roll - Over - funktion
Having selected "HIPER" in the measuring system menu,
the following menbu appears.
This special measuring system is used if the CamCon is
equiped with an incremental measuring system input and
an odd resolution of a gear would cause an adding
measuring failure.
1.
Enter the gear realtion first by the multiplier and
devisor (e.g. 5 / 7).
Note: Every change of edges is counted =
quadruplication
2.
Now enter the total number of steps i.e. incremts that can be counted by the CamCon (e.g. 360).
If more impulses are counted than set as resolution here, the CamCon restarts counting at zero. If
the movement measuring system was set to "linear" at the menu configuration way, the CamCon
switches to "Clear....". In this case the resolution has to be set greater or the actual value is set to
zero, setting a clear signal.
In the filed "Clear mode" you can set the functions of the additional inputs C1 and C2 using the
3.
keys
and
. You can choose between 8 different types of functions: "C1 & C2", "/C1 & C2",
"C1 & /C2", "/C1 & /C2", "C1 : W", "/C1 : W", "C1 or áC2" und
"C1 or âC2". Seee also
chapter "7.4.1.6.3. Incremental - measuring system" on page 49.
4.
Use the
key to confirm youre inputs and leave rthe menu.
,Version from: Aug. 04
Page: 53
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.4.1.7. Deleting the special measuring system
The special configuration of the measuring system can be removed as follows:
1.
Select the menu point "Measuring system" in the
configuration menu. The following menu is
displayed:
2
Select the special measuring system with the
and
keys.
3.
Press the
displayed:
4.
Move the cursor to "yes" with the
key, and the following question is
confirm your choice by pressing the
key and
key.
This deletes all settings of the special measuring system.
,Version from: Aug. 04
Page: 54
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.4.2. The measuring offset
If you selected the menupoint "Measuring offset" in the system setting menu, the measuring offset
menu appears on the menu:
Here you can indicate, using the
and
keys, wether
your controlling system is a rotatory (e.g. an eccentric
press) or a linear (e.g. a knee lever press) moved
system.
You confirm your input with the
key.
7.4.2.1. Zero offset with rotatory movements
If you have chosen a rotatory movement, you can now carry out the input of the offset
The offset is subtracted from the physical position. This
makes it possible for you to shift the zero point.
7.4.2.2. Measuring offset with a linear moved system
If you have chosen a linear movement, you can now carry out the input of the moving range and the
offset.
At the menu point "Start" you enter the desired begin of
the proceeding range. You even have the possibility to
enter negative values.
The "End" value of the measuring range changes
automatically and determines the total proceeding way of
the measuring system with its position. Here an input is
not possible.
Attention: If the range between start value and end
value is under- or overshot during the way gathering of the measuring system, the
CamCon switches off with the error message "Pos.Err 3".
7.4.2.3. Zero offset with linear movements
If you have chosen a linear movement, you can now
carry out the input of the offset.
In the menu point "Offset" you enter the zero offset of the
measuring system. The offset is subtracted from the
physical position. This makes it possible for you to shift
the zero point.
Note:
If the rotation direction of the electronic gear is negative, the offset must be set to a value
samller than zero (e.g. -359). See chapter "7.4.1.4.1. Electronically changing the rotation
direction" on page 47.
,Version from: Aug. 04
Page: 55
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.4.2.4. Actual position preset
In the measuring offset menu you have the possibility with the rotary system and the linear system to
set the actual position to a new value by creating a new input (preset).
By setting the preset value to zero, you can generate an external zero signal, e.g. to synchronize the
cycle of the machine and the actual position of the CamCon.
When you have entered the preset value, the device
requests the input number of the preset signal with which
the preset is supposed to be initiated. Enter the number
next to the "P-In"-put line.
Afterwards select, using the keys
and
in the input
field "type", the mode of storage of the preset value.
Here you have two possibilities:
- "RAM" storage.
Here the preset value is copied into the RAM memory of the device. This means that after switching
the device off and on again, the shifting of the actual position equals the zero offset or the offset is no
longer available.
- "EEPROM" storage.
Here the shifting of the actual position is copied into the RAM and into the EEPROM memory of the
device, making it safe to shut off the device without loosing your data.
Attention:
You should only store your data in the EEPROM memory, if the triggering of the preset
just occurs rarely and is absolutely required. This is because of the fact that an
EEPROM only has a limited number of writing cycles: 100000). Shooting over this
maximum number of writing cycles leads to the destruction of the EEPROM and the
loss of the program data of the CamCon.
Note:
The preset input will be read in real-time since the software of the 21.5.2002. Therefore, a
synchronisation of a device already running is impossible.
Pressing
you can leave the menu.
,Version from: Aug. 04
Page: 56
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.4.3. The speed adjustment
If you selected the menu "Speed" in the system setting
menu, the speed adjustment menu appears on the
display:
You can use it to optimally adjust the speed of the device
to the speed of the gear.
7.4.3.1. The speed factor
Normally the speed is displayed through the number of
increments or impulses per second, an output of the
measuring system. If you want the speed displayed e.g. in
rotations per minute or in the number of pieces per
minute, you have to enter a randomizing factor.
Example 1:
A rotation encoder with 512 steps supplies 512 increments per minute, which means
that the gear runs with 1 rotation per minute. The CamCon measures 512/60 = 8,533
increments per second.
To receive a display in rotations per minute enter the factor 1/8,533 = 0,1172.
Example 2:
A rotation encoder with 360 steps supplies 360 increments per minute, which means
that the gear runs with 1 rotation per minute. The CamCon measures 360/60 = 6
increments per second.
Enter a factor of 1/6 = 0,16666 to have the display remain in rotations per second.
Note:
The speed factor is influenced by inputs in an electronic gear. Also see chapter "7.4.1.4.
The electronic gear" on page 47.
7.4.3.2. The display format of the speed display
When you have adjusted the speed range with the factor, you can enter the presentation format of the
display, using the
and
keys (see chapter "5.8. Text input" on page 27).
The # symbols are place holders for the displayed value. If
e.g. the highest value is lower than 1000 and only has
three digits, you only enter three # symbols. If you want a
decimal point displayed, just insert it between the symbols
(e.g. : ###.##). Press the
the next menu point.
key, and the curser moves to
7.4.3.3. Range adjustment of the speed display
In this menu point you enter the maximum speed of your gear or the speed of your movement. This
input is used to adjust the speed display.
An input of e.g. 1000 rotations per minute means that at
+/-1000 rotations per minute the maximum analog output
voltage, (100%) +/-10V, is reached.
This scale also applies to the speed bar that is shown in
the middle of the standard display. Its length is the current
speed compared to the entered reference speed in
percent. Furthermore this is the point of the speed where
the standard display switches from the position to the
current speed. This point always lies at 5% of the here
entered value, for 1000 rotations per minute it lies at 50 rotations per minute.
,Version from: Aug. 04
Page: 57
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.4.3.4. Accuracy of the speed display
During operations the speed display usually fluctuates by a certain value. These fluctuations are
accounted for in the measuring priciple for the speed, since it is a scanning system.
In the menu point "Exact" you can limit these fluctuations
to a maximum value. It is a damping through a low pass
that results in a smoothing of the display, which means
that an averaging process is put into operation. The lower
the input value is, the quieter is the speed display. In
practice, you will always find a compromise between the
dynamics of the display and its readability.
Note:
The "Exact" value also corresponds to the speed value, which is provided by an CP16 or
CamCon DC115 of an PLC.
7.4.3.5. Display, Type
If you want to prevent the automatic switching at the 5% of
the maximum speed in the "Display" menu point, you can
select one of the three different display types with the
key and the
"Automatic"
"Speed"
"Position"
key.
At the 5% point the display is switched from the position display to the speed
display. This bar display shows the speed in percent.
Only the speed is shown on the display. The bar display shows the speed in
percent.
Only the position is shown on the display. The bar display does not show the speed,
but
it
displays
the
position
between
0%
and
100%
e.g. 0% = 0 Degree / 50% = 180 Degrees / 99% = 359 Degrees.
In addition to the three display types, you can also select
the desired display type through an input. The display type
has to be set to either "Speed" or "Position", and the
number of the input has to be entered in the field behind.
When input is passive, the set display type is displayed.
When you supply a signal, the display changes from
"speed" to position or from "position" to "speed".
Press the
menu.
key to confirm your inputs and exit this
,Version from: Aug. 04
Page: 58
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.4.4. Cable length / Cycle time
If you selected the menu "Cable length/Cycle time" in
the system setting menu, the following menu is set up on
the display:
7.4.4.1. The cable length
In this menu point you can set the conduction length
between the SSI measuring system and the CamCon, as
well as between external input or output extensions and
the CamCon, in meters. This is necessary, since the cable length determines the maximum possible
speed of serial data transmission. The larger the set cable length, the larger is the cycle time of the
transmission and the slower is the data traffic. The cable length can be set to a maximum of 1000m.
Attention!! With cables exceeding 300m in length use a corresponding measuring system as well as
extensions with a changed mono-flop-time.
7.4.4.2. The cycle time of the CamCon
Normally the CamCon operates with the shortest
possible cycle time. It is displayed as long as the cursor
is not on the menu field "Cycle time". With an input in
the menu field "Cycle time" this time value can be
changed.
This might become necessary, if e.g.:
you are programming a large number of outputs with
delay time or with a high measuring system
resolution and need longer single delay times. These depend on the available memory and the
cycle time ( see chapter "12. Calculation the RAM storage-requirement for" on page 85). A
noticable change occurs only when the set value lies above the current cycle time. For this reason
the display also shows the maximum possible speed compensation.
you connect a measuring system that allows the readout of the data only once in a given time.
Press the
key to end your input and exit the menu.
7.4.5. The special outputs
If you selected "Special outputs" in the system setting
menu, the special outputs menu appears on the display:
7.4.5.1. The security output
To have the possibility to supervise the CamCon e.g. after
short circuits on the output channels or mistakes in the
measuring system, you can program a circulation cam for
a single output, so that this output is switched off at the occurence of a mistake and serves as a
security output. With a program change, the security output is reset for a short time (see chapter
"7.4.6.8. Setting the program selection mode" on page 64).
A "0" in the input field defines that no security output has been programmed..
,Version from: Aug. 04
Page: 59
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.4.5.2. The output of the actual position
The CamCon offers the possibility to put the physical
actual position out to outputs. It is used when several
CamCon need the same actual position (Master Slave
connection). To be able to use this option, the number of
the programmed outputs has to be lower than the number
of the actually available ones (see chapter "7.4.6.2.
Setting the outputs" on page 63. The output of the bit with
the lowest value will occur after the last programmed
output. The other bits follow in increasing order.
With the
and
keys you can choose 4 possible output formats:
"No"
"Gray"
"Bin."
"Exp."
=
=
=
=
Confirm your input with the
No output of the actual position.
Output of the actual position in the gray code.
Output of the actual position in the binary code.
Output of the actual position in the gray code only for CamCon DC115.
key.
7.4.5.3. Direction output
To be able to recognize the direction of the movement of a
machine with different movement directions, you can
program an output that switches on at a positive and off at
a negative movement.
7.4.5.4. The standstill output
The CamCon offers the possibility of a standstill
surveilance. Here you can define an output that is
switched on when the actual speed is greater than the at
"dir Hyst." entered value and that switches off when the
speed drops below that value again.
7.4.5.5. The hysteresis
To be able to use the options of movement direction surveilance and standstill surveilance correctly,
you have to set the hysteresis. This value is needed to suppress the jittering of the outputs at small
changes in speed. This value can only be determined through experiments, but it should be as small
as possible.
,Version from: Aug. 04
Page: 60
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.4.5.6. The analog speed output
CamCon emitts a voltage (proportional to the speed) on
the first analog output (pin 2 at CamCon DC50), 0 to -10V
with a negative rotation direction and 0 to +10V with a
positive rotation direction, if the menu point "Speed
Analog" is set to "yes".
The output voltage reaches its maximum of 10V, when the
100% value, described in chapter "7.4.3. The speed
adjustment", is surpassed.
You can deactivate this function by setting the menu point to "no" with keys
confirming it with the
Note:
and
, and
key.
At the time, there are no integrated analog outputs available for CamCon DC16 and
DC90. You can add analog outputs by connecting a CamCon DAC16 digital - analog converter module to the external interface of the CamCon.
To clear the integrated analog outputs please see chapter "7.5.3.3.1. Clearing the
integrated analog outputs" on page 72.
Note:
7.4.5.7. Configuration of the analog cams
With a CamCon cam controller you have the possibillity to
make an output of free programmable analog values
(cams) dependent on the position. You enter the number
of analog outputs in the menu point "Analog cams", that
you want to program via the CamCon. In most cases, this
will also be the number of your analog hardware outputs.
Note:
If the menu point "Speed Analog" is set
to "yes", the first analog output is used to
display the speed, and the number of possible analog outputs is decreased by one.
When you enter the number and press the
key, you
enter the input of the specific settings for the analog cams:
First you choose the number of the nalog output with keys
and
.
Press the
key to confirm the number and change the
display to the input of the display format.
Here you enter your desired format, as described in
chapter "5.8. Text input" on page 27. It is e.g. possible to
make the input in percent "####.##%" (standard), in
voltage "###.###V", in bar "#.###mbar" or in Ampere
"##.###mA". The double-crosses are just placeholders for
the real numerical values. The skaling of the input values
is done in menu points "Minimum" and "Maximum".
,Version from: Aug. 04
Page: 61
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
When you confirm the format with the
input for the minimum value.
, you enter the
Note that CamCon always calculates with an accuracy of
16 Bit. The minimum value is the bit value 0 (e.g. -10V or
4mA) and the maximum value is the bit value 65535
(e.g.+10V or 20mA). The values should be entered
according to the purpose of the device. If e.g. an CamCon
DAC16/I module (current output) is connected to the
external display, the input can be made in milliampere, or the milliampere value corresponds to a
physical preassure - or speed, this value can also be entered in bar or meters per second (see values
in figure above).
Note:
The integrated analog outputs of the CamCon DC40, 50 and 115 all work with an
accuracy of 8 Bit. The output of the analog cam values is recalculated from 16 bit to 8
bit in this case.
After the minimum and maximum values have been confirmed with the
key, the com inputs in the
programming menu are restricted to the range between minimum and maximum and recalculated, if
necessary.
The output of the analog value can be stopped by setting an input to a specific value. For this purpose
enter the input number in the menu point "Dis.inp." (Disable Input), with which the analog value is set
to the "Dis.val." (Disable Value). The "Dis.value" must be within the range of minimum and maximum.
The "Dis.val." is automatically set as a default value, if no cam has been programmed on the analog
output.
When the "Dis.val." is confirmed you can activate ("yes") or deactivate ("no") the interpolation of the
analog value with the keys
and
in the menu point "Interpol.". If this value is set to "yes",
CamCon interpoles the programmed values from definition point to definition point.
Example:
without interpolation
with interpolation
+10V
+10V
0°
90°
180°
-10V
270°
360°
0°
90°
180°
270°
360°
-10V
By pressing the
key, the input of the interpolation is confirmed, and you move back to the selection
of the number of the analog oiutput. Here you can choose the number of the next analog output with
the keys
and
and proceed with the input of the values as before.
When the input is finished, you can leave the menu by pressing the
key.
For the input of the cam values please see chapter "7.3.17. Programming analog cams" on page 43.
,Version from: Aug. 04
Page: 62
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.4.5.8. The analog position output
The analog position output of the CamCon can be programmed with a software version of at least
DC50.20, by the input of an analog cam. Herefore you program an analog cam, that emitts -10V at an
actual position of 0 degrees and +10V at an actual position of 359 degrees (see chapter "7.3.17.
Programming analog cams" on page 43).
7.4.6. System upgrading
If you selected the menupoint "System upgrading", the
following menu appears on the display:
7.4.6.1. Setting the inputs
Here you can enter the number of inputs available to the
CamCon. This number of inputs should always be exactly
the same as the number of electrical inputs, since the
short circuit detection of the CamCon reacts to the number of inputs.
7.4.6.2. Setting the outputs
Here you can enter the number of outputs available to the CamCon. This number of outputs should not
be greater than the number of electrical outputs, since this only results in a waste of memory and cycle
time. If you want to make an output of the actual position at the outputs, you have to decrease the
number of outputs by the corresponding number of bits (see chapter "7.4.5.2. The output of the actual
position" on page 60.
7.4.6.3. Setting the outputs with speed compensation
Here you can enter the number of outputs with speed compensation available for the CamCon. The
number of outputs should not be greater than the maximum number of the absolute necessary outputs;
otherwise only memory and cycle time are wasted.
7.4.6.4. Setting the keyboard lock
Assigning a +24VDC level to the programmed input pin will disable the keyboard. After this it is not
possible to program or initialize the device any more. Resetting the value to "0" will enable the
keyboard again.
7.4.6.5. Error - aknowledging Input (EQ)
A positive edge (+24V DC)at the inputnumber shown here leads to aknowledgeing an error-notice at
the CamCon "Pos-Error": 1,2,3 and 5 but not an output error"
7.4.6.6. Input for enableling Outputs
A signal (+24V DC) at the input-number shown here enables Cam-outputs, an 0 signal locks
Camoutputs. If this value is set to "0", the "enableling function is inactive and the Cam-outputs are
permanentely enabled.
Note:
Note:
If a PLC-Logic-module is switched on, this effects rather the "0"-outputs but the Camoutputs "N".
Using a CamCon with direct PLC-attachement via CP16 or CP340 respective a
CamCon DC300 and 1756-DICAM, these enableling-functions should be switched off
(0), for the PLC-enableling-function takes on their function.
,Version from: Aug. 04
Page: 63
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.4.6.7. Setting the external program selection
With the CamCon you have the possibility to externally select the desired program number through the
inputs. Here you enter the number of programs that can be selected externally, and this simultaneously
predefines how many inputs will be used for this purpose. Then the input for the take over impulse is
stated. The program number is created as a binary number at the inputs after the take over impulse.
The bit with the lowest value is the input after the take over impulse, all others then follow it in an
increasing order. Because of this the inputs for program selection are completely relocatable.. With an
impulse (+24V) the program is selected at the input of the take over impulse. This impulse has to be
created at least 20 ms after the program number and has to be at least 20 ms long.
7.4.6.8. Setting the program selection mode
You can change programs in several ways. Here you have the possibility to determine the desired way
to change the programs with keys
"slow"
"direct"
"on position"
and
. You can select between:
Here the selected program is built up cam after cam. This type of program changing
requires the least memory, but a complete change of programs during a full run can
lead to complication with the machine. In this case the security output of the CamCon
is switched off for a short time.
Here the selected program is built up cam after cam in an intermediate memory and
changes the full program at once. This type of program changing requires the double
amount of memory for the cam build up, but the outputs are always defined in every
cycle. The security output of the CamCon will not be switched off in this case.
The program is built up in the same way as in the "direct" type, but here the CamCon
waits with the program change until the machine has passed a certain position and
then makes a complete program change. This type of program changing also requires
the double amount of memory for the cam build up, but the outputs are always defined
in every cycle. The security output of the CamCon will not be switched off in this case.
,Version from: Aug. 04
Page: 64
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.4.7. Masterprogram
Having selected "Masterprogram" in the menu "system config" you will get to the following display.
.
or.
Here you are able to define Cams for different products and programms. They could be necessary if
your plant produces different types of products that have only very little differences concerning their
Cam-adjustement. You are able to save a lot of storage for Cams (EE-Prom), because these
mastercams do not need to be programmed multiple.
If you wish to use this funktion, at first the "Mastermodule"
must be switched "on" using key
confirmed by pressing
, that has to be
.
Now enter the masterprogramnumber by wich the
Mastercams will be saved. You can use every
programnumber from 0 to 32767.
Having confirmed the masterprogramnumber by pressing
, you have to define which Output or Camtrack shall be
used as Mastercam.
Here
you
can
switch
the
outputs
acess
to
the
masterprogram on (YES) or off (NO) by pressing
and
The keys
and
are used to select the
favoured Outputmuber or Camtrack. Pressing
the input.
quits
Example:
Having adjusted the masterprogramnumber 32767 on and switched output 1 on YES, a Cam in
Program 32767 programed for output 1 will be also editet, if automaticprogram is set to 0. Cams in
Programm 0 programed for output 1 will be ignored though.
To program a Mastercam, switch to menu "programing" and choose your favoured outputnumber. If
you are not in the Masterprogram while putting in Cams, the system automatically switches to
Masterprogram so that you can change a Mastercam.
Note:
In putting in Cams in the "Programing"-menu the only posibility to change Mastercams, if
your logged in with an user key, that has acess to "System config". This disables a user
at the plant to change MasterCams. The procedure of the plant can therefore only be
changed by a person that has the essential acess-key-code.
Note:
If choosing the Masterprogram to program Cams, only MasterCams may be changed.
Note:
If an automatic-program is set on the Masterprogram's number, only the Cams
programed by Masterprogram will be put out.
,Version from: Aug. 04
Page: 65
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.5. Unit configuration
At the first activation of the CamCon, you should initiate a
complete deletion and, if desired, allocate the user keys
for associates. To do this, select the main menu point
"Unit configuration". The display changes to display the
configuration menu:
7.5.1. User key allocation
You can assign different user keys to your associates, each with different access rights.
Attention:
As long as no key is created, you can enter every menu with the key code
"5693". When you create your first key, this master key is automatically
deleted. If you forget to create at least one key that allows access to the
configuration menu, you have locked yourself out of the configuration menu
as soon as you leave it. This can be overcome by sending the unit back to
Digitronic or with the entry of a special supervisor number. You can aquire this number
with a phonecall to Digitronic Automationsanlagen.
7.5.1.1. Creating a new user key
Follow these steps to create a new user key:
1.
Select the menu point "Key allocation" in the
configuration menu; the display changes to the key
allocation menu:
2.
Press the
key, and the input field for the name
is underlayed in black.
Enter a name. See chapter "5.8. Text input" on page
27.
3.
4.
5.
6.
End the text input with the
key, and the cursor
moves to the input field "Key number".
Enter the key code with the numeric keys (up to 5
numbers).
Press the
key. The cursor moves to the input
field for the access to the program selection.
7.
Choose between "yes" and "no" with keys
and
.
8.
9.
Choose between "yes" and "no" with keys
10. Press the
and
.
key. The cursor moves to the input field for the access to the system menu
11. Choose between "yes" and "no" with keys
12. Press the
Press the
key. The cursor moves to the input
field for the access to the cam programming.
and
.
key. The cursor moves to the input field for the access to the configuration menu.
,Version from: Aug. 04
Page: 66
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
13. Choose between "yes" and "no" with keys
and
.
14. Press the
key. The cursor moves to the input field for the access to the outputs, generally
and for every output.
15. Choose between "yes" and "no" with keys
and
.
16. Press the
key. If you chose "no" in the previous input field, you can now assign the access to
each output one by one.
The cursor moves to the input field for the access to output No. 1.
17. Choose between "yes" and "no" with keys
18. Press the
and
key. The cursor moves to the input field for the access to output No. 2 and so on...
19. You can leave this menu at any time by using the
Note:
.
key.
You can also select the menu fields for the single access rights with keys
and
.
7.5.1.2. Deletion of a user key
You can delete a user key according to the following
procedure:
1.
Select the menu point "Key allocation" in the
configuration menu; the menu for the key allocation
appears:
2.
Select the user key you want to delete with keys
3.
Press the
and
.
key; the display shows the question:
4.
Move the cursor to "yes" with the
5.
Press the
Additionally:
key.
key, and the key is deleted.
If you happen to delete every key in this
menu, the standard key code "5693" is
automatically generated.
7.5.1.3. Checking the key configuration
You can check an allocated key the following way:
1.
Choose the menu point "Key allocation" in the
configuration menu; the menu for the key allocation
appears:
2.
Select the key that is to be checked with keys
and
3.
.
Now you can check the single access rights mit
keys
and
.
,Version from: Aug. 04
Page: 67
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.5.2. Complete deletion
If you selected the menu point"Complete deletion" in the "Unit configuration" menu, the display
shows :
You can move the cursor to "yes" with the
key and confirm it with
.
After a short while the display returns to the main menu. This time depends on the size of the
EEPROM used, since the memory has to be formatted. Using e.g. a 32k EEPROM the process takes
about 2 minutes. Afterwards, the complete deletion is complete. All cams are deleted, and the system
registers have their standard values.
Now you can begin with the programming.
Attention:
Deleted information cannot be restored.
,Version from: Aug. 04
Page: 68
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.5.3. Unit configuration
If you selected the menu point "Configure unit" in the "Unit configuration" menu, configuration
menu appears on the display:
7.5.3.1. Setting the serial interface
You can select the mode of the serial interface with keys
and
in the input field "Ser.mode", confirming your
selection with the
.key afterwards There are five
different types of operation available : 1. = "Cam-BUS", 2.
= "Standard", 3. = "Multiuser", 4. = "S5-L1" and 5. =
"3964R". When you select a specific communication
mode, you have to make sure, that every connected
device you want to make contact with supports this communication mode. Please note also, that you
can specify the type of serial interface with your order of the CamCon. You can choose between an
RS232 or an RS485 interface. All four "Ser.Modes" operate with the RS232 point to point
communication as well as with the RS485 BUS communication. See also chapter "4.1.7.2. Pin
allocation of the serial RS485 interface" on page 18 and chapter "7.5.3.1.6. Input of the unit number"
on page 70.
Note:
As a standard, the device comes with Ser.Mode set to "Multiuser" and the unit number
set to "0" .
7.5.3.1.1. The "Cam-BUS" communication mode
Select this mode, if you want to be able to program or display CamCon cam controllers from different
places, e.g. you want the CamCon, the daughter display CD10 and the PC via the RS485 BUS.
Attention: Using the configuration above or similar requires that all CamCon devices, as well as any
connected PC be equipped with an RS485 serial interface and a software of at least
December 1996.
7.5.3.1.2. The "Standard" communication mode
The standard mode operates with point to point communication, i.e. you can only connect 2 devices,
e.g. a CamCon to a PC or a CamCon to a CamCon DC50/51 Terminal. Since this communication
mode does not use any protocol security, its usage is only allowed for testing purposes.
7.5.3.1.3. The "Multiuser" communication mode
Contrary to the "Cam-BUS" mode, it is "not" possible to operate several devices, e.g. CamCon
Terminal DC51/T4, the daughter display CD10 and the PC, on the RS485 BUS. (PRESET)
7.5.3.1.4. The "S5 - L1" communication mode
This setting is neccessary, if you want to program the CamCon device via a Siemens S5 CPU. The
process is a point to point communication, i.e. you can only connect the CamCon and the Siemens S5
CPU. If you want to store the data of your CamCon on a PC, you have to brake your connection to the
S5 CPU. For the S5 - L1 communication mode, you can order a connection set compsed of : a TTY
cable, function segments and a handbook (Ordering.No.: PCXX/S5-L1 XX=CamCon Type).
7.5.3.1.5. The "3964(R)" communication mode
This setting is neccessary, if you want to program the CamCon device via a seriell interface with the
RK512 prozedur. The process is a point to point communication.
,Version from: Aug. 04
Page: 69
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.5.3.1.6. Input of the unit number
In the Multiuser and in the Cam-BUS operation, you need to set a unit number for every device on the
BUS. This number can be set under the menu point "UnitNo:" and is then displayed in the main menu
in the highest line on the display. You may only allocate each unit number once for a single linked
RS485 BUS operation. Because of this, you need to set the "UnitNo" and the "Multiuser" or "CamBUS" mode for every device separatly, before connecting the serial interfaces.
7.5.3.1.7. Programming via remote
If you want to program the CamCon from a separat control, you can order a handbook with a
description of the programming sequences (Ordering.no.: H-DC50/PROTO).
7.5.3.2. Additional device options
At the time, the CamCon has the options "PLC", SPS/INFO/HSR and "PLC/INFO" available. If want
your CamCon to be equipped with one of these options, please specify with your order : ("PLC" = S)
("PLC/INFO" = M) ("SPS/INFO/HSR" = C).
These options are described in an extra handbook (H-PLC), which is not in the supply package of the
CamCon.
7.5.3.2.1. PLC Logic Module
The firm Digitronic Automationsanlagen GmbH is an accomplished and well-known supplier and
developper of electronic cam controllers for the industry. The experiences of connecting PLC controlls
and cam controllers, collected in years of close cooperation with the users, have been regarded during
the creation of the PLC Logic Module. The result is a PLC software for the CamCon, that works parallel
to the cam controller. The in- and outputs of the cam controller are linked without external logics or
hardware, e.g. Timers (Way - Time - Cams), Set - Reset - Functions, and registers and can so be
operated within the cycle time of the cam controller. This combination guarantees the best possibility of
using the advantages of the CamCon speed compensation and the logic of the PLC, without the loss of
switching speed because of slow external switching elements (e.g. relays, timers and central PLC
controlls with high cycle time).
7.5.3.2.1.1. Examples for using the PLC logic module
Example 1:
Output deactivation.
Output 1 of the CamCon is cleared if inputs 1 and 8 are active.
,Version from: Aug. 04
Page: 70
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Example 2:
Output depending on the rotation direction.
Output 1 of the CamCon is
enabled when the rotation
direction output 32
is active.
This is the case when the direction
of the rotation is positive.
Example 3:
Digital Cam Switch Unit
CamCon DC50/51
Output 1 of the CamCon is
enabled when the rotation
direction output 32
is not active.
This is the case when the direction
of the rotation is negative.
Flank assessment.
Register 2 is activated for one cycle when the signal at input 1 changes from 0 to 1.
Register 2 is activated for one cycle when the signal at input 2 changes from 1 to 0.
7.5.3.2.2. PLC Logic Module with text display
Available with the PLC Logic Module is a text display you can use to show and describe the different
states of your machine.
Example:
,Version from: Aug. 04
Page: 71
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.5.3.3. Analog outputs
The electronic cam controllers of the CamCon series are equipped with analog outputs (CamCon
DC40/50/51 optionally, CamCon DC115 as a standard), via which speed, position or the cam values
can be emitted as analog signals.
Note:
With units CamCon DC16, DC90 and DC300 you can only use the analog outputs by
connecting a CamCon DAC16 digital - analog - converter to the external interface.
7.5.3.3.1. Clearing the integrated analog outputs
At the time, units CamCon DC40/50/51 (optionally) and
CamCon DC115 (as a standard) are supplied with integrated
analog outputs. The outputs are cleared by setting their number
in the menu point "Int.Anlg". The possible numbers are 0,1
and 2. A value of 0 deactivates the integrated outputs.
Note:
Not possible with CamCon DC16 and DC90.
If the value is greater than 0, a line for adjustments appears
below the menu point "Int.Anlg".
7.5.3.3.2. Adjusting the integrated analog outputs
Note:
With units of increment DC51/S5.., DC51/J5.. or DC40/S5.. this feature is neither
necessary nor possible.
The integrated analog outputs of the CamCon have to be regulated from time to time and after the first
activation. Offset and amplification can be adjusted. The maximum analog output voltage is ±10V with
a resolution of 8Bit. Should you wish for a smaller voltage range, you can edit the maximum voltage via
the amplification factor.
Offset output 1
Amplification factor output 1
With keys
and
you can set the amplification and the offset through repeated ajustments with
the keys and measuring the analog output voltage. From analog output 1 to analog output 2 and to
switch between offset and amplification factor, press keys
made, the input is ended with the
,
or
. When all 4 adjustments are
key and the menu is left.
See also chapters "7.4.5.6. The analog speed output" on page 61, chapter "7.3.17. Programming
analog cams" on page 43 and chapter "7.4.5.7. Configuration of the analog cams" on page 61.
7.5.3.3.3. External analog outputs
Additional external analog outputs can be connected to a CamCon through a CamCon DAC16 digital analog - converter module at the external interface.
,Version from: Aug. 04
Page: 72
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.5.3.4. Locking EEProm memory
If an PLC-controll writes or programs parameter, Cams or Delay-Times cyclical (eg. DC300 or CP16)
the unit's EEProm-Memory will be destroyed after a short time. If cyclical programming is, for a certain
reason, necessary, you therefore have to lock the EEProm.
Therefore select S-EE in menu "unit configuration" and change it by pressing
to "locked". If the
EEProm is locked, all data will only be written to RAM and will be deleted if the voltage is switched off.
Attention:
After having finished a complete deleting, this value is set to "unlocked" again.
,Version from: Aug. 04
Page: 73
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.5.4. Language
If you selected the menu point "Language" in the "Configuration" menu, the menu for the language
setting appears:
Here you can move the dark field to the desired language using the keys
adapt the selected language by pressing the
,
,
and
. You
key.
7.5.5. Configure user
If you choose the menu-point "Configure User" in the menu "Unit Configuration", the following menu
appears on your display.
7.5.5.1. User text
If you selected the menu point "User text" in the "Configuration menu", the following menu appears
on the display. Here you can enter general information about e.g. your machine for the CamCon to
display. There are 7 lines available, with 21 characters each.
For the input of the text please see the chapter "5.8. Text input" on page 27. You can store the text and
move on to the next page by pressing the
key. You can exit this menu at any time with the
,Version from: Aug. 04
key.
Page: 74
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
7.5.5.2. User-Menu/OP-functions
If you choose the menu-point "Configure User" in the menu "User menu", the following menu
appears on your display.
Here you are able to feed in own input- or displayfunctions into the CamCons Standart-Display. This
helps the final customer to change or controll Cams, delay-times and Variables of the PLC-LogicModule without having to interfere with the units sub-menus.
For informations about Input or definition of this feature please read chapter "User's menu/ OPFunctions" in the PLC-Logic-Module's manual (Best.Nr: H-SPS).
7.5.6. Configure Hardware
Fill in the physical inputs and outputs here.
Using e.g. a CamCon DC90 this would be 16 inputs and 24
outputs, using a DC16 8 inputs and 16 Outputs, using a
CamCon DC300 8 inputs and 24 outputs or using a CamCon
1756-DICAN 0 inputs and 24 outputs.
7.5.6.1. CP16 Module
If a CP16 Profibus (CP16/P) or Interbus (CP16/I) Module
gets connected to your CamCon, you can switch the CP-type
by pressing
key
to "Profibus" respective "Interbus"-press
.
Using a Profibus-DP-Module you can now enter your
favoured Profibus-DP-adresse and confirm by pressing
.
Additional to the CamCon's physical In - or Outputs the
CP16 - module is able to simulate In - or Outputs, that can
be evaluated or controlled by an PLC
Attention:
Note:
Simulated Inputs, controlled by PLC must not be directly frequented in Cam-switch or
PLC-Logic-module, forbeeing not defined for an accurate establishing of comunication
between CamCon CP16 and CamCon Cam-switch. The Inputs therefore have to be
connected with special-input 5 of the PLC-Logic-module AND, which will be set to 1 if
sucessfully establishing comunication to CP 16.
For more information about the features of an CP16 Module please read the CP16
manual.
,Version from: Aug. 04
Page: 75
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
8. Device info
If you want to get an overview of whole configuration of the CamCon, you should select the information
menu of the unit configuration. Select the main menu point "Unit configuration", and press the
key during the input of the user code (the input of the user key is not required here) or you press the
key in the "configuration menu". The first page of the information menu appears on the display.
With the help of the arrow keys or the
all times by pressing the
key you can view the other pages. You can exit this menu at
key.
-
User text inputs
-
-
Software version
Number of free cams / number of programmed
cams
Maximum delay time setting
Maximum setting for the physical resolution of
the measuring system
Size of the RAM in bytes
Size of the EEPROM storage in byte
-
Configured measuring system
Actual position hysteresis (Hy.)
Encoder controlling (Vmax)
Rotation direction and gear factor
Display format of the actual position
Display of actual Value
-
detailed configuration of the measuring system
-
Configured moving system
Activation point of the linear moved system
Offset (shifting of the zero point)
Value of the actual position preset
Input number of the actual position preset /
Memory of the actual position preset
-
,Version from: Aug. 04
Page: 76
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
-
Factor of the speed display
Display format of the speed display
100% value for the speed display
Accuracy of the speed display
Display menu of the display type / Input for the
display change.
-
Cable length of the measuring system and the
external upgrade
Set planned value of the cycle time
Cycle time need by CamCon
Temperature in the encasement of CamCon
-
-
Output number of the security output
Format of the displayed actual value
Output number of the F / R output
Output number of the stand still output
Hysteresis for the recognition of the stand still
speed
Analog speed output "yes/no"
Number of analog cam outputs
Number of inputs and outputs
Number of outputs w. speed compensation
Input number for keyboard locking
Input number of error aknowledgement
Input number for output enable
Number of externally selectable programs
Input number of the first input for the external
program selection
Change mode of the program selection
-
Configuration of physcial hardware in- and
outputs
-
Configuration towards the CP-16-module
(Profibus, Interbus, Can-Bus).
-
PLC logic module configuration
PLC-Logic-module ON/OFF
Number of M-Registers
Number of X-Registers
Number of counters and times
Number of virtual inputs
Number of special inputs.
Number of shift registers with speed
compensation
,Version from: Aug. 04
Page: 77
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
-
Mode of the serial interface
Unit number
additional options of the e.g. PLC option
or PLC option with text display
Number of internal analog outputs
CPU - Speed (clock) 16 or 25 Mhz
Hardware PLC - acceleration (on/off)
-
Configuration of the analog cam 1,2, up to 13.
Input and display format
Minimal input value ( - 10V)
Maximum input value ( + 10V)
Input number for switch to dis.value
Output value if switch off
Interpolation yes/no
For each of the analog cam the CamCon displays one more information menu. A maximum of 13
analog cam are possible.
-
Adjustements for OP-functions.
For each line of a menu-page information-menus are
shown.
8.1. Stack Info
If a non-defined error happens while the CamCon is in operation, the user is able to controll the stackvariables' allocation which helps the software developers detection of effects. Use to stack-informationmenu for this purpose.
Please note the information shown on screen. At the moment, we are able to show a maximum of 6
stack-informnation menus. Please note their content and send it by fax to. +49/6126/945342.
Note:
Using a CamCon DC16; 40; 50/51 and DC90 only 4 stack-menus are shown. these are
called iotask, rs232task, dc40task and main A CamCon DC 115 also shows tasks
called DC115_0, DC115_1; a CamCon DC300 also shows DC300.
,Version from: Aug. 04
Page: 78
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
9. Error messages and removal of errors (FAQ)
The error messages appear on the standard display or in CamCon DC16, 90, 115, 300 and 1756DICAM without a display of their own through the status LED or status bits.
The drawing below shows the error message appearing for 'Position - Error 3'.
The display for other errors is almost the same.
9.1 Problem: Display shows "No contact to unit: XX".
Possible causes:
The wiring is probably not correct, no device with the selected unit number is on the BUS or the setting
of the 'Ser.Mode' is wrong.
Solution:
Check the wiring and the configuration of the serial interface.
See chapter "4.1.7.2. Pin allocation of the serial RS485 interface" on page 18 and chapter "7.5.3. Unit
configuration" on page 69.
9.2. Problem: "Pos - Err:1".
Possible causes:
The measuring system has not been correctly connected.
Solution:
Please check the wiring to the measuring system. Please consult the instruction manual to the
measuring system.
If the error is eliminated, the error-message can be deleted by pressing
9.3. Problem: "Pos - Err:2".
Possible causes:
The measuring system is faulty or not connected.
The setting of the error bits in the special measuring system setting is not correct.
Solution:
Check the wiring to the measuring system.
Check the inputs of the measuring system resolution.
Consult the instruction manual of your measuring system.
If the error is eliminated, the error-message can be deleted by pressing
,Version from: Aug. 04
Page: 79
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
9.4. Problem: "Pos - Err:3".
Possible causes:
The resolution of the connected measuring system is not in accord with the input resolution. The
measuring system is faulty. The actual value is outside the range which was entered in the menu path
setting for linear systems. See Chapter "7.4.2.2. Measuring offset with a linear moved system" on page
55. If an incremental measuring system is set, then this report is an alternative for the message
"Clear...".
Solution:
Check the input of the measuring system setting and the cable length setting.
Consult the instruction manual of your measuring system.
Consult Chapter "Problem: Clear...".
If the error is eliminated, the error-message can be deleted by pressing
9.5. Problem: "Pos - Err:5".
Possible causes:
The measuring system control is activated. The CamCon has registered a large unacceptable actual
value jump. The measuring system is possibly faulty.
Solution:
Check the input of the measuring system setting and of the setting of the cable length or increase the
permitted actual value jump. Consult Chapter "7.4.1.3. Controlling the measuring system" on page 46.
Consult the instruction manual of your measuring system.
If the error is eliminated, the error-message can be deleted by pressing
9.6. Problem: An "Pos-Error:" occurs during operation.
The monitor displays "Pos-Err:1", "Pos-Err:2", "Pos-Err:3" or "Pos-Err:5".
Possible causes:
The connection cable of the measuring system or the measuring system itself is defective. A cable
without screening or without dual strand was used. The laying of a connection cable in the vicinity of a
strong electromagnetic source of interference (e.g. high voltage cable, motor cable) can lead to an pos
error.
Solution:
Check the wiring to the measuring system. Replace the measuring system.
Take measures for screening.
Lay the connection lead in another location.
Consult the instruction manual of your measuring system.
If the error is eliminated, the error-message can be deleted by pressing
9.7. Problem: "RAM-Full" = RAM memoryis full.
Possible causes:
The resolution of the measuring system is too large.
The number of outputs is too high.
The number of Speed Compensated outputs is too high.
Solution:
Check the input of the measuring system setting.
Reduce the measuring system resolution.
Reduce the number of Speed Compensated outputs.
Please contact your customer service representative if you require a RAM memory extension.
,Version from: Aug. 04
Page: 80
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
9.8. Problem: The EEProm memory is full.
Cause:
Too little memory space available in the EEPROM for the storage process.
Solution:
Please contact your customer service representative if you require an EEProm storage extension.
Also consult Chapter "11. Calculation EEPROM cam storage on page 84.
9.9. Problem: Outputs will not activate
Possible causes:
An error message is active. The outputs are not connected to power supply. A programed Cam is to
short or gets to short by increasing rotation speed. The enable - Input is not set.
Solution:
Check the error message.Program a longer Cam. A Cam with delay-time/speed-compensation must at
least have the length of two steps.
Enable Outputs at the enable-Input, see also chapter 7.4.6.6. Input for enableling Outputs on page 63
Enable the outputs through the S5 PLC. Consult your handbook for the S5-L1 linkage.
9.10. Problem: "Out - Error".
Possible causes:
Your outputs are overloaded or short-circuited. Check the wiring and the connection output as well as
possible inductive loads which have no zero setting or are driven by a cancellation component.
The number of set inputs is not correct.
Power failure at an external interface module (e.g. DC91/IO or DC16/IO).
Solution:
See chapter "4.3. The outputs" on page 24.
See chapter "7.4.6. System upgrading" on page 63.
See chapter "7.5.6. Configure Hardware" on page 75.
If the error is eliminated, the error-message can be deleted by pressing
Here the attempt to reset outputs is done
Warning:
Wires crossing behind the outputs, if the cables leading towards the switchOFF of the outputs are in an awkward position, can lead to a switch-OFF of the
outputs, since in an open situation a potential is built up which, when the
contacts are closed, is led back into the outputs.
In inductive loads the outputs must be organised with a flywheeling diode. Protection or
induction in the switch cabinet in the immediate vicinity of the device or due to their wiring
have an effect on the device or its wiring and must be organised with cancellation
components.
9.11. Problem: Error in the EEPROM.
Possible causes:
The data of the EEPROM was changed or destroyed by interference.
One of the existing data carriers (EEPROM or EPROM) was renewed or is defective.
The power supply was switched OFF during alteration of the data.
Solution:
Press
for yes and then the
key. All data will be erased and must be re-entered.
Should these errors occur repeatedly, please contact your customer service.
9.12. Problem: "Error ???"
Possible causes:
An unpredictable error has occurred.
Solution:
Please contact your customer service.
,Version from: Aug. 04
Page: 81
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
9.13. Problem: "Clear...."
Cause:
The CamCon is waiting for the arrival of the Clear signal in an incremental measuring system.
Solution:
Set the Clear signal ON or activate an actual value Preset. The result is the immediate release of the
Cam Switch Unit.
Note:
The incremental measuring system is only available as an option for CamCon DC16,
DC50/51, DC115, DC300 and CamCon 1756-DICAM.
See chapter "7.4.1.6.3. Incremental - measuring system" on page 49.
,Version from: Aug. 04
Page: 82
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
10. Menu outline
,Version from: Aug. 04
Page: 83
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
11. Calculation EEPROM cam storage
In the CamCon you have the opportunity to extend the EEPROM Cam storage. The storage space
required for programming is influenced by the following factors:
1. Basic requirement
2. Per cam
3. Per set delay time for Speed Compensation
4. Per name for an output
5. Per set key / code
6. For a special measuring system
7. For direct or ”actual” program selection
8. Per set program name
9. Per line of the OP function
= 256 Bytes
= 12 Bytes
= 12 Bytes
= 24 Bytes
= 66 Bytes
= 66 Bytes
= 12 Bytes
= 48 Bytes
= 72 Bytes
The value is generated by the CamCon with the following formula:
Storage requirements in Bytes
Example 1:
=
+
+
+
+
+
+
+
+
Basic needs
Number of cams * 12
Number of delay times for Speed Compensation * 12
Number of output names * 24
Number of user keys * 66
66 when the special measuring system is available.
12 when "on Pos" program selection is set.
48 * number of set program names.
72 * number of set lines of the OP function.
The Cam Switch Unit is supposed to have 8 Programs each with 16 cams and Speed
Compensation for 16 outputs.
Storage requirement in Bytes = 256 Bytes + ( 8 Programs * 16 * 12 Bytes ) + ( 16 * 12 Bytes )
Storage requirement = 1984 Bytes
Example 2:
The Cam Switch Unit is supposed to have 20 programs each with 16 cams and 16
delay times for Speed Compensation.
Storage requirement in Bytes
=
+
+
+
+
256 Bytes
( 20 Programs * 16 * 12 Bytes )
( 16 TZK * 12 Bytes )
( 16 Output names * 24 Bytes )
( 1 User keys * 66 Bytes )
Storage requirement = 4738 Bytes
Warning:
Through alterations in the storage structure of the CamCon software, the extent to
which storage capacity is used up can differ from software version to software version!
,Version from: Aug. 04
Page: 84
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
12. Calculation the RAM storage-requirement for CamCon
The required RAM-main storage (not similar to the constand value - Camstorage or the EEPROM)
depends on 7 factors:
1. Standard consumption
2. Number of outputs
3. Cycle time
4. Actual value/measuring system
resolution
5. Maximal Speed-compensation
6. Mode of program selection
(approximately 100000 Byte)
( 8 to 200 in steps of 8 outputs).
(displayed in miliseconds).
(displayed in impulses)
( 0 to 9999.9 in steps of 100 microseconds).
(the double ammount of storage is required ).
( See also chapter "7.4.6.8. Setting the program selection
mode" on page 64).
( EE-Prom - storage size in Byte for Cache ).
7. Size of the EE-Prom storage
The RAM - storage requirement is calculated by the following formula:
storage requirement in Bytes =
standard consumption +
Number of outputs * IActual value resolution.* ( 2 If program Mode not slow )
+
8
max. delay-time * 4
+ EE-Prom size
cycletime
Example 1:
The camswitch with a resolution of 360°, an EE-Promstorage of 32kByte, 16 outputs, a
speed-compensation of 1000ms and a cycletime of 250µs needs:
Storage requirement in Bytes = 100000 +
16 * 360
1000 * 4
+ 0.250 + 32768
8
Storage requirement in Bytes = 100000 + 720 + 16000 + 32768
Storage requirement in Bytes = 149488 = ca. 150kByte
Example 2:
The camswitch with a resolution of 8192°, an EE-Promstorage of 48kByte, 64 outputs,
a speed-compensation of 500ms and a cycletime of 250µs, needs:
64 * 8182
500 * 4
+ 0.250 + 49152
8
Storage requirement in Bytes = 100000 + 65536 + 8000 + 49152
Storage requirement in Bytes = 100000 +
Storage requirement in Bytes = 222688 = ca. 220kByte
Note:
If the required RAM - storage requirement greater than the CamCons total ammount of
storage, you need to reduce the measuring system's resolution.
Attention: Changings in the storage-structure of the CamCon software the storage requirement can
alternate at different software-versions!
,Version from: Aug. 04
Page: 85
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
13. Technical data of the CamCon
Display .................................................graphical display with 128x64 pixels for user prompting and
programming (optional with background illumination)
Number of outputs ...............................8, 16, 24, 32 expandable up to 200 through the expansion bus
Number of inputs..................................8, 16 expandable up to 200 through the expansion bus.
Analog output .......................................2 optional analog outputs for the speed display or for the
programming through analog cams
Number of programmable cams ..........150, optionally 600, 2500, 3700 or 10500 cams
Data security/storage ...........................EEPROM
Number of programs............................32768
Cycle time ( switching speed ) .............from 0,1ms, is adjusted to the needs (optimized)
Dead time compensation (DTC) ..........individually adjustable for every output according to the
measuring system and the memory
Adjustment range of the DTC ..............0 to max. 9999.9ms according to the measuring system and
memory
Exactness of the DTC..........................+0 to -1 step
Measuring system input .......................synchronous serial (SSI), gray coded, optional incremental data
input, optional parallel data input, analog data input, PLL data
input, time controlled data input
Resolution of the measuring system....360 steps (standard), otherwise adjustable according to
measuring system and memory
Measuring system SSI ........................AAG60007 (360 degree SSI standard type) AAG612-2048,
AAG612-4096,AAG612-8192, AAG626 oder AAG66107.
Border frequency
of the incremental input........................about 200kHz
Input level
of the incremental input........................5V RS244 or 24V PNP.
Zero point correction
of the measur. sys. ..............................is programmed by the CamCon
Rotation direction
of the measuring sys............................is programmed by the CamCon
Length of the connection cable
between the measuring system
and the CamCon..................................with SSI to max. 300m (optionally up to 1000m)
Supply voltage......................................24V DC ±20 %
Measuring system supply voltage ........with 24V DC through the supply voltage of the CamCon
Current reception .................................300mA without measuring system and outputs
Output voltage......................................24V DC, plus switching
Output current ......................................500mA per output, short circuit proof permanent current (see
chapter 4.3. The outputs on page 24).
Connections for:
Measuring system ................................through plug block pins
Voltage supply......................................through plug block pins
Cam outputs.........................................through plug block pins
Operating temperature.........................0°C to +55°C
Cover type for:
Front plate / full sight gate....................IP 67 / IP 55
Cabinet.................................................IP 54
Dimensions ..........................................see fig. page 14
Front plate part.....................................138+1 x 138+1mm
Cabinet:
Switch plate cabinet by DIN 43700 ......144 x 144 x 63mm (wxhxd)
Cover of the front plate ........................optional full sight gate, can be locked
Weight..................................................about 1000g
,Version from: Aug. 04
Page: 86
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
14. Key word table
3964(R) .................................................................................................................................................. 70
Actual position preset............................................................................................................................. 57
Actual position, Output........................................................................................................................... 61
Adding cams .......................................................................................................................................... 37
Adding cams, Example .......................................................................................................................... 42
AG615 - Single - Multiturn - Measuring system ..................................................................................... 53
Analog cam, Adding............................................................................................................................... 45
Analog cam, Changing........................................................................................................................... 45
Analog cam, Configuration..................................................................................................................... 62
Analog cam, First creation ..................................................................................................................... 45
Analog cams, Programming .................................................................................................................. 44
Analog measuring system input............................................................................................................. 23
Analog outputs ....................................................................................................................................... 73
Analog outputs, adjusting....................................................................................................................... 73
Analog outputs, Clearing integrated....................................................................................................... 73
Analog outputs, External........................................................................................................................ 73
Analog, Position output .......................................................................................................................... 64
Analog, Speed output............................................................................................................................. 62
brake functions....................................................................................................................................... 13
Cable covers .......................................................................................................................................... 15
Cable length ........................................................................................................................................... 60
Cam deletion.......................................................................................................................................... 38
Cam input............................................................................................................................................... 36
Cam programming ................................................................................................................................. 33
Cam search............................................................................................................................................ 37
Cam track, Deletion ............................................................................................................................... 38
Cam-BUS............................................................................................................................................... 70
CE ............................................................................................................................................................ 3
centre pressure ...................................................................................................................................... 13
Clear....................................................................................................................................................... 83
Commissioning ...................................................................................................................................... 29
Communication mode............................................................................................................................ 70
Complete deletion .................................................................................................................................. 69
Configure Hardware............................................................................................................................... 76
configure user. ....................................................................................................................................... 75
Connections ........................................................................................................................................... 16
Contrast setting...................................................................................................................................... 26
Controll................................................................................................................................................... 47
Controlling the measuring system.......................................................................................................... 47
Copying cam tracks ............................................................................................................................... 39
Copying programmed outputs................................................................................................................ 39
Copying programs.................................................................................................................................. 40
CP Inputs/Outputs.................................................................................................................................. 76
CP16 Module ......................................................................................................................................... 76
Cycle time .............................................................................................................................................. 60
Delay time compensation, Effects.......................................................................................................... 10
delay time for Speed Compensation, separate for switch-ON and switch-OFF points.......................... 14
Delay time, Calculation .......................................................................................................................... 12
Deleting programs.................................................................................................................................. 40
Deletion of a particular cam, Example ................................................................................................... 43
Device info ............................................................................................................................................. 77
Dimensions ............................................................................................................................................ 15
Direction output...................................................................................................................................... 61
Dis.input. with analog cams ................................................................................................................... 63
,Version from: Aug. 04
Page: 87
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
Dis.value with analog cams ................................................................................................................... 63
Display format, Actual position............................................................................................................... 48
Display, Change..................................................................................................................................... 31
Display, LCD .......................................................................................................................................... 26
Display, Standard................................................................................................................................... 31
Display, Type ......................................................................................................................................... 59
DP adresse ............................................................................................................................................ 76
EEPROM cam storage, Calculation....................................................................................................... 85
EEProm storage is full ........................................................................................................................... 82
EEPROM, Error ..................................................................................................................................... 82
Enable, outputs ...................................................................................................................................... 64
Encoder-controll..................................................................................................................................... 47
Error - aknowledging, intput ................................................................................................................... 64
Error messages...................................................................................................................................... 80
Examples for cam programming............................................................................................................ 41
External interface ................................................................................................................................... 20
External program selection, Setting ....................................................................................................... 65
Gear, Electronic ..................................................................................................................................... 48
Grounding pins....................................................................................................................................... 15
HIPER - measuring system.................................................................................................................... 54
Hiperface................................................................................................................................................ 23
Hysteresis .............................................................................................................................................. 61
Hysteresis, Actual position ..................................................................................................................... 46
incremental ............................................................................................................................................ 54
Incremental - measuring system, Configuration .................................................................................... 50
Incremental measuring system input ..................................................................................................... 22
Input of text ............................................................................................................................................ 28
Input wiring............................................................................................................................................. 25
Inputs, In general ................................................................................................................................... 25
Inputs, Setting ........................................................................................................................................ 64
Inputs, Status display............................................................................................................................. 31
Installation .............................................................................................................................................. 15
Installation procedures........................................................................................................................... 15
Interbus .................................................................................................................................................. 76
Interpol. with analog cams ..................................................................................................................... 63
Key functions, Outline ............................................................................................................................ 27
Keyboard................................................................................................................................................ 26
Keyboard lock, Setting ........................................................................................................................... 64
Keys, Checking ...................................................................................................................................... 68
Language ............................................................................................................................................... 75
Linear system, Measuring offset............................................................................................................ 56
Locking EEProm memory ...................................................................................................................... 74
MachineCams ........................................................................................................................................ 66
Machineprogram .................................................................................................................................... 66
Main menu ............................................................................................................................................. 31
MasterCams........................................................................................................................................... 66
Masterprogram....................................................................................................................................... 66
Measuring offset .................................................................................................................................... 56
Measuring system .................................................................................................................................. 46
Measuring system, General information ................................................................................................ 21
Measuring system, Selection ................................................................................................................. 46
Menu outline........................................................................................................................................... 84
Menu point, Selection............................................................................................................................. 27
,Version from: Aug. 04
Page: 88
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
Menu, Selection ..................................................................................................................................... 27
millenium .................................................................................................................................................. 3
Movement direction, Change ................................................................................................................. 48
Multiturn measuring system with electronic gear................................................................................... 51
Multiuser................................................................................................................................................. 70
No contact to unit XX ............................................................................................................................. 80
Offset ..................................................................................................................................................... 56
OP - Function......................................................................................................................................... 76
Options, Additional................................................................................................................................. 71
Out - Error .............................................................................................................................................. 82
Output name, Programming .................................................................................................................. 36
Output selection for programming ......................................................................................................... 33
Output, Deletion ..................................................................................................................................... 38
Outputs with DTC, Setting ..................................................................................................................... 64
Outputs, 40mA ....................................................................................................................................... 25
Outputs, 500mA ..................................................................................................................................... 25
Outputs, additional ................................................................................................................................. 76
Outputs, In general ................................................................................................................................ 25
Outputs, lock .......................................................................................................................................... 64
Outputs, Setting ..................................................................................................................................... 64
Outputs, Status display .......................................................................................................................... 31
Parallel - Gray special measuring system.............................................................................................. 50
Parallel measuring system input ............................................................................................................ 21
PDF - File ................................................................................................................................................. 3
Pin allocation.......................................................................................................................................... 16
Pin allocation, Analog outputs................................................................................................................ 16
Pin allocation, Incremental measuring system....................................................................................... 17
Pin allocation, Inputs .............................................................................................................................. 17
Pin allocation, Outputs ........................................................................................................................... 17
Pin allocation, Serial interface................................................................................................................ 18
Pin allocation, SSI measuring system.................................................................................................... 16
Pin allocation, Voltage supply ................................................................................................................ 18
PLC Logic Module.................................................................................................................................. 71
PLC Logic Module with text display ....................................................................................................... 72
PLC Logic Module, Examples................................................................................................................ 71
PLL measuring system .......................................................................................................................... 52
PLL measuring system input.................................................................................................................. 24
Pos - Err 1.............................................................................................................................................. 80
Pos - Err 2.............................................................................................................................................. 80
Pos - Err 3.............................................................................................................................................. 81
Pos - Err 5.............................................................................................................................................. 81
Preset..................................................................................................................................................... 57
Profibus.................................................................................................................................................. 76
Program change .................................................................................................................................... 32
Program name ....................................................................................................................................... 32
Program number.................................................................................................................................... 32
Program selection for programming ...................................................................................................... 34
Program selection mode........................................................................................................................ 65
Programing way-Cams .......................................................................................................................... 35
Programming ......................................................................................................................................... 33
Programming the delay time/speed compensation , Private ................................................................. 34
Programming via remote ....................................................................................................................... 71
RAM, storage requirement, calculation.................................................................................................. 86
RAM-Full ................................................................................................................................................ 81
RK512 Prozedur..................................................................................................................................... 70
Roll - Over .............................................................................................................................................. 54
Rotation direction, Change..................................................................................................................... 48
,Version from: Aug. 04
Page: 89
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com
Digitronic
Automationsanlagen GmbH
Digital Cam Switch Unit
CamCon DC50/51
RS232 as a measuring system .............................................................................................................. 24
RS232 measuring system...................................................................................................................... 53
S5 - L1.................................................................................................................................................... 70
Security output ....................................................................................................................................... 60
Ser.mode ............................................................................................................................................... 70
Serial interface ....................................................................................................................................... 18
Serial interface RS232 ........................................................................................................................... 18
Serial interface RS485 ........................................................................................................................... 19
Serial interface, Configuation................................................................................................................. 70
Shifting cam tracks ................................................................................................................................ 39
SIM - measuring system simulator ........................................................................................................ 54
Special measuring system ..................................................................................................................... 49
Special measuring system, Deletion...................................................................................................... 55
Special outputs....................................................................................................................................... 60
Speed adjustment .................................................................................................................................. 58
speed compensation for on-/off-switchpoint .......................................................................................... 34
Speed Compensation, Effects ............................................................................................................... 10
Speed display, Accuracy........................................................................................................................ 59
Speed display, Display format................................................................................................................ 58
Speed display, Range adjustment ......................................................................................................... 58
Speed factor........................................................................................................................................... 58
SSI - measuring system......................................................................................................................... 49
SSI measuring system input .................................................................................................................. 21
Stack Info ............................................................................................................................................... 79
Standard................................................................................................................................................. 70
Standstill output...................................................................................................................................... 61
System upgrading .................................................................................................................................. 64
Table of contents ..................................................................................................................................... 4
Teach - In............................................................................................................................................... 37
Technical data........................................................................................................................................ 87
Text input ............................................................................................................................................... 28
Time -Cam ............................................................................................................................................. 14
Time emitter measuring system simulation ........................................................................................... 52
Timer as a measuring system................................................................................................................ 24
Unit configuration ....................................................................................................................... 46; 67; 70
Unit number, Input ................................................................................................................................. 71
UP - Date ................................................................................................................................................. 3
User key, Creation ................................................................................................................................. 67
User key, Deletion.................................................................................................................................. 68
User keys, Allocation.............................................................................................................................. 67
user menu .............................................................................................................................................. 76
User terminal, Outline ............................................................................................................................ 26
User text................................................................................................................................................. 75
Vmax...................................................................................................................................................... 47
Welding operations, Safety precautions ................................................................................................ 25
Y2K .......................................................................................................................................................... 3
Zero offset.............................................................................................................................................. 56
Zero offset, External............................................................................................................................... 57
,Version from: Aug. 04
Page: 90
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com