F0-04AD-1
CLICK PLC
$83.00
Do-More
PLCs Overview
4-channel analog current input module
Do-More H2
PLC
F0-04AD-1 Input Specifications
Input Range
0 to20mA or
4 to 20mA
(jumper selectable)
Resolution
12 bit (1 in 4096)
Step Response
25.0mS (typ.)
to 95%
of full step change
Active Low-pass Filtering
Input Impedance
Absolute Max Ratings
Converter Type
DirectLOGIC
PLCs Overview
DirectLOGIC
DL05/06
DirectLOGIC
DL105
1/2 count max
(-80db)*
-3dB at 40Hz
(-12dB per octave)
125h w0.1%,
1/8 watt
-30mA to +30mA,
current input
Successive
approximation
DirectLOGIC
DL205
DirectLOGIC
DL405
Productivity
Controller
Overview
CH4
Linearity Error (end to end) w2 counts
Input Stability
DirectLOGIC
DL305
CH3
Crosstalk
Do-More T1H
PLC
CH1
4, single ended
(one common)
CH2
Number of Channels
w1 count*
counts max.
Full-scale Calibration Error w10
@ 20mA*
Offset Calibration Error
w5 counts max.
@ 4mA*
Max Inaccuracy
w0.4% at 25-C
(77-F)
w0.85% at 0 to 60-C
(32 to 140-F)
Accuracy vs. Temperature
w100 ppm/-C typical
Terminal Type (Included)
Removable: F0-IOCON
Recommended Fuse
0.032A, series 217
fast-acting,
current inputs
Productivity
3000
Universal
Field I/O
Software
C-More
HMI
See Wiring Solutions for
part numbers of ZIPLink
cables and connection
modules compatible with
this I/O module.
C-More Micro
HMI
ViewMarq
Industrial
Marquees
* One count in the specification table is equal to one
least significant bit of the analog data value (1 in 4096)
Other HMI
Communications
Appendix
Book 1
Terms and
Conditions
Book 1 (14.2)
www.automationdirect.com
DL05 / DL06 PLCs
eDS-83
Prices as of April 15, 2015. Check Web site for most current prices.
DL05/06 I/O Option Modules
F0-04AD-2
$120.00
4-channel analog voltage input module
F0-04AD-2 Input Specifications
Number of Channels
4, single ended
(one common)
Input Range
0 to 5VDC or
0 to 10VDC
(jumper selectable)
Resolution
12 bit (1 in 4096)
Step Response
10.0mS to 95%
of full step change
Crosstalk
1/2 count max
(-80db)*
Active Low-pass Filtering
-3dB at 300Hz
(-12dB per octave)
Input Impedance
L20Kh
Absolute Max Ratings
w15V
CPU
Firmware Required DirectSOFT32 Required
DL05
Version 4.60 or later
Version 3.0c or later
DL06
Version 1.40 or later
Version 4.0, Build 16 or later
A n a l o g Input
4-CHANNELS
0–5V
0–10V
CH1+
CH2+
count (0.025%
Linearity Error (end to end) w2
of full scale) max*
Input Stability
w1 count*
Gain Error
w6 counts max*
Offset Error
w2 counts max*
Terminal Type (Included)
Removable: F0-IOCON
Max Inaccuracy
Accuracy vs. Temperature
w0.3% at 25-C (77-F)
w0.6% at
0 to 60--C
(32 to 140-F)
w100 ppm/-C typical
CH3+
CH4+
0V
0V
0V
0V
See Wiring Solutions for part
numbers of ZIPLink cables
and connection modules
compatible with this I/O
module.
F0–04AD–2
* One count in the specification table is equal to one
least significant bit of the analog data value (1 in 4096)
Book 1 (14.2)
eDS-84
DL05 / DL06 PLCs
1-800-633-0405
Prices as of April 15, 2015. Check Web site for most current prices.
DL05/06 Option Modules
Company
Information
Control Systems
Overview
F0-08ADH-1
CLICK PLC
$134.00
Do-More
PLCs Overview
8-channel analog current input module,
high resolution
Do-More H2
PLC
Input Specifications
Do-More T1H
PLC
Number of Channels
8
Input Range
0-20mA
Resolution
16-bit, .305µA/bit
Input Type
Single Ended
(one common)
Maximum Cont. Overload
±31mA
Input Impedance
100 ohms, 1/10W,
current input
Low pass,
-3dB @ 60Hz
16-bit, Unsigned
Int., 0–FFFF (binary) or
0–65535 (BCD)
(Both require 2 words
of V-memory)
10.2ms
(time to 95% of full
step change / channel)
Filter Characteristics
PLC Data Format
Sample Duration Time
All Channel Update Rate
Open Circuit
Detection Time
81.6ms
Conversion Method
Successive
Approximation
Accuracy vs. Temperature
±50PPM/°C Max.
Maximum Inaccuracy
Linearity Error (End to End)
IN
0–20mA
DirectLOGIC
DL05/06
CH1
CH2
DirectLOGIC
DL105
CH3
CH4
COM
DirectLOGIC
DL205
CH5
CH6
DirectLOGIC
DL305
CH7
CH8
COM
DirectLOGIC
DL405
COM
+24V
Productivity
Controller
Overview
0V
F0-08ADH-1
Zero reading
within 1s
Productivity
3000
Universal
Field I/O
Typical User Wiring
0.2% of range
(including temp.
changes)
±10 count max.;
Monotonic with no
missing codes
Offset Calibration Error
Maximum Crosstalk at DC,
50 Hz and 60 Hz
External 24VDC Power
Required
Base Power Required
(5.0V)
±10 count max.
Terminal Type (Included)
Removable: D0-ACC-4
Recommended Fuse
Littelfuse Series 217,
.032A fuse
4-20mA Transmitter
Shield, Ch. 1
SEE NOTE 1
2-wire 4–20mA
Transmitter
4-20mA Transmitter
Shield, Ch. 3
.032A
AC or DC
4-wire 4–20mA
Transmitter
3-wire 4–20mA
Transmitter
CH3
25mA
CH2 ADC
100 Ω
CH3 ADC
100 Ω
CH4 ADC
100 Ω
CH5
CH5 ADC
100 Ω
4-20mA Transmitter
Shield, Ch. 5
+
CH1 ADC
100 Ω
COM
±10 count max.
CH6 ADC
100 Ω
CH8
4-20mA Transmitter
Shield, Ch. 8
CH7 ADC
100 Ω
C-More
HMI
C-More Micro
HMI
ViewMarq
Industrial
Marquees
Other HMI
CH8 ADC
100 Ω
COM
Software
Communications
COM
+24VDC
SHIELD CONNECTED TO SIGNAL
SOURCE COMMON. SEE NOTE 2.
25mA
Firmware Required
Internal Module Circuitry
CH1
2-wire 4–20mA
Transmitter
Input Stability and
±10 count max.
Repeatability
Full Scale Calibration Error ±10 count max.
CPU
DirectLOGIC
PLCs Overview
ANALOG
Note 1: A Littelfuse Series 217, 0.032A fast-acting fuse
is recommended for all 4-20mA current loops.
Note 2: Do not connect both ends of shield to ground.
ISOLATED ANALOG
CIRCUIT POWER
0VDC
Terms and
Conditions
0V
24VDC
Power Supply
DirectSOFT Required
DL05
Version 5.20 or later
DirectSOFT32 Version 3.0c or later
DL06
Version 2.30 or later
DirectSOFT32 Version 4.0, Build 16 or later
See Wiring Solutions for
part numbers of ZIPLink
cables and connection
modules compatible with
this I/O module.
Book 1 (14.2)
www.automationdirect.com
Appendix
Book 1
DL05 / DL06 PLCs
eDS-85
Prices as of April 15, 2015. Check Web site for most current prices.
DL05/06 I/O Option Modules
F0-08ADH-2
$144.00
8-channel analog voltage input module,
high resolution
Input Specifications
Number of Channels
8
Input Range
0-5VDC or
0-10VDC
(Jumper select)
IN
ANALOG
0–10V
CH1
Input Type
16-bit, 76µV/bit or
152µV/bit
Single Ended (one
common)
Maximum Cont. Overload
±100V
COM
Input Impedance
>200k ohms
Filter Characteristics
Low pass, -3dB @
60Hz
16-bit, Unsigned
Int., 0–FFFF (binary) or
0–65535 (BCD)
(Both require 2 words
of V-memory)
Resolution
PLC Data Format
CH2
CH3
CH4
CH5
CH6
CH7
CH8
COM
COM
+24V
0V
F0-08ADH-2
Sample Duration Time
10.2 ms
All Channel Update Rate
81.6 ms
Conversion Method
Successive
Approximation
Accuracy vs. Temperature
±50PPM / °C
Maximum
Maximum Inaccuracy
0.2% of range
(including temp. drift)
Linearity Error (End to End)
Input Stability and
Repeatability
Full Scale Calibration Error
(including Offset)
Offset Calibration Error
±10 count max.
Monotonic with no
missing codes
±10 count (after 10
min. warm up)
±10 counts max.
±10 count max.
Maximum Crosstalk at DC, ±10 count max.
50 Hz and 60 Hz
25mA
External 24VDC Power
Required
25mA
Base Power Required
(5.0V)
CPU
Firmware Required
Typical User Wiring
3-wire Voltage
Transmitter
+
Voltage Transmitter
Shield, Ch. 1
3-wire Voltage
Transmitter
+
Voltage Transmitter
Shield, Ch. 3
Internal Module Circuitry
CH1
CH1 ADC
CH2 ADC
CH3
CH3 ADC
CH4 ADC
COM
AC or DC
4-wire Voltage
Transmitter
3-wire Voltage
Transmitter
CH5
CH5 ADC
Voltage Transmitter
Shield, Ch. 5
+
CH6 ADC
CH7 ADC
CH8
Voltage Transmitter
Shield, Ch. 8
CH8 ADC
COM
COM
+24VDC
SHIELD CONNECTED TO SIGNAL
SOURCE COMMON. SEE NOTE 1.
ISOLATED ANALOG
CIRCUIT POWER
0VDC
Note 1: Do not connect both ends of shield.
24VDC
Power Supply
0V
DirectSOFT Required
DL05
Version 5.20 or later
DirectSOFT32 Version 3.0c or later
DL06
Version 2.30 or later
DirectSOFT32 Version 4.0, Build 16 or later
See Wiring Solutions for
part numbers of ZIPLink
cables and connection
modules compatible with
this I/O module.
Book 1 (14.2)
eDS-86
DL05 / DL06 PLCs
1-800-633-0405
Prices as of April 15, 2015. Check Web site for most current prices.
DL05/06 I/O Option Modules
Company
Information
Control Systems
Overview
F0-04THM CLICK PLC
$207.00
Do-More
PLCs Overview
4-channel thermocouple input module
F0-04THM 4-Channel Thermocouple Input
Type J -190 to 760ºC
Type E -210 to 1000ºC
Type K -150 to 1372ºC
Type R 65 to 1768ºC
Type S 65 to 1768ºC
Type T -230 to 400ºC
Type B 529 to 1820ºC
Type N -70 to 1300ºC
Type C 65 to 2320ºC
General Specifications
Number of Channels
4, differential
Common Mode Range
-1.3VDC to +3.8VDC
Common Mode Rejection
100dB min. @ VDC 50/60Hz.
Input Impedance
5Mq
Absolute Maximum Ratings
Fault-protected inputs to ±50 VDC
Accuracy vs. Temperature
(Max. Full Scale Error)
±15ppm/ºC maximum
0 - 1.25V ±35ppm/ºC maximum
(including maximum offset change)
PLC Update Rate
4 channels per scan
Digital Inputs
None; uses special V-memory location based on slot
Base Power Required
30mA @ 5VDC supplied by base
Operating Temperature
32º to 140ºF (0º to 60ºC)
Storage Temperature
-4º to 158ºF (-20º to 70ºC)
Relative Humidity
5 to 95% (non-condensing)
Environmental Air
No corrosive gases permitted
Vibration
MIL STD 810C 514.2
Shock
MIL STD 810C 516.2
Noise Immunity
NEMA ICS3-304
Input Ranges
Firmware Required
Display Resolution
Cold Junction
Compensation
Conversion Time
-310 to 1400ºF
-346 to 1832ºF
-238 to 2502ºF
149 to 3214ºF
149 to 3214ºF
-382 to 752ºF
984 to 3308ºF
-94 to 2372ºF
149 to 4208ºF
±0.1ºC or ±0.1ºF
DirectSOFT Required
Version 4.60 or later
DirectSOFT32 Version 3.0c or later
DL06
Version 1.40 or later
DirectSOFT32 Version 4.0, Build 16 or later
30 minutes typically ± 1ºC repeatability
Warm-Up Time
Linearity Error (End to ±1ºC maximum, ±0.5ºC typical
End)
DirectLOGIC
DL105
Productivity
Controller
Overview
±3ºC (excluding thermocouple error)
Voltage Ranges
Resolution
Max. Offset Error
(All Input Ranges)
Linearity Error
(All Input Ranges)
16 bit (1 in 65535)
Productivity
3000
Universal
Field I/O
Software
0.05% @ 0-60ºC;
Typical: 0.04% @ 25ºC
C-More
HMI
0.05% @ 0-60ºC;
Typical: 0.03% @ 25ºC
Thermocouple Input wiring diagram
DirectLOGIC
DL05/06
DirectLOGIC
DL405
0-39.0625mV, ±39.0625mV, ±78.125mV,
0-156.25mV, ±156.25mVDC, 0-1.25V
Maximum Inaccuracy
DirectLOGIC
PLCs Overview
DirectLOGIC
DL305
270ms per channel
Voltage Input Specifications
DL05
Do-More T1H
PLC
DirectLOGIC
DL205
Automatic
Maximum Inaccuracy
Terminal Block Replacement F0-IOCON-THM (comes with CJC)
CPU
Do-More H2
PLC
Thermocouple Specifications
0-39.0625mV, ±39.0625mV, ±78.125mV ranges:
0.1% @ 0-60ºC; Typical: 0.04% @ 25ºC
0-156.25mV, ±156.25mVDC, 0-1.25V ranges:
0.05% @ 0-60ºC; Typical: 0.04% @ 25ºC
Voltage Input wiring diagram
C-More Micro
HMI
ViewMarq
Industrial
Marquees
Other HMI
See NOTE 1
Transmitter
Supply
CH1+
CH1–
Communications
–
+
Voltage
Transmitter
CH2+
Appendix
Book 1
CH1+
See NOTE 2
CH1–
Terms and
Conditions
CH2–
CJC
CH2+
ADC
CJC
MUX
LM35
See NOTE 3
CH2–
See NOTE 3
CJC
LM35
CJC
ADC
CH3–
MUX
CJC
CH3+
internal
connection
internal
connection
CJC
CH3+
CH4+
See NOTE 1
CH4–
Voltage
Transmitter
CH3–
See NOTE 2
+
Voltage
Transmitter
+
–
CH4+
CH4–
Notes:
1. Shields should be grounded at the PLC power source only.
2. Unused channels should have a shorting wire (jumper) installed from CH+ to CH-.
3. All CH- terminals must be connected together.
4. This module is not compatible with the ZIPLink wiring system.
www.automationdirect.com
Book 1 (14.2)
DL05 / DL06 PLCs
eDS-87
Prices as of April 15, 2015. Check Web site for most current prices.
DL05/06 Option Modules
F0-04RTD
$207.00
4-channel RTD input module
F0-04RTD Input Specifications
Number of Channels
4
Input Ranges
Type Pt100: -200.0/850.0ºC,
-328/1562ºF
Type Pt1000: -200.0/595.0ºC,
-328/1103ºF
Type jPt100: -38.0/450.0ºC,
-36/842ºF
Type CU-10/25: -200.0/260.0ºC,
-328/500ºF
Type NI-120: -80.0/260.0ºC,
-112/500ºF
Resolution
Display Resolution
RTD Excitation Current
Notch Filter
Maximum Setting Time
Common Mode Range
Absolute Maximum
Ratings
Sampling Rate
F0-04RTD Input Specifications (cont’d)
Terminal Type (included)
Converter Type
Linearity Error
Maximum Inaccuracy
PLC Update Rate
Removable: D0-ACC-4
Charge Balancing
±.05ºC maximum, ±.01ºC typical
±1ºC
4 channel/scan
Digital Input Points Required None; uses special V-memory location based on slot
Base Power Required 5VDC
Operating Temperature
Storage Temperature
Temperature Drift
Relative Humidity
Environmental Air
Vibration
Shock
Noise Immunity
16 bit (1 in 65535)
±0.1ºC, ±0.1ºF (±3276.7)
200 µA
> 50 db notches at 50/60 Hz
100 ms (full-scale step input)
0-5 VDC
Fault protected inputs to ±50 VDC
70 mA
32° to 140°F (0° to 60°C)
-4º to 158ºF (-20º to 70ºC)
15 ppm / °C max
5 to 95% (non-condensing)
No corrosive gases permitted
MIL STD 810C 514.2
MIL STD 810C 516.2
NEMA ICS3-304
140 ms per channel
Notes:
CPU
Firmware Required
DirectSOFT Required
DL05
Version 4.70 or later
DirectSOFT32 Version 3.0c or later
DL06
Version 1.50 or later
DirectSOFT32 Version 4.0, Build 16 or later
1. T he three wires connecting the RTD to the module must be the same type and
length. Do not use the shield or drain wire for the third connection.
2. U
nused channels require shorting wires (jumpers) installed from terminals CH+ to
CH– to COM to prevent possible noise from influencing active channels. This should
be done even if the unused channel is not enabled in the V-memory configuration.
3. If an RTD sensor has four wires, the plus sense wire should be left unconnected as
shown.
4. This module is not compatible with the ZIPLink wiring system.
Note 1
Note 3
x
COM
COM
ANALOG MULTIPLEXER
Note 2
CH1+
CH1COM
CH2+
CH2COM
CH3+
CH3COM
CH4+
CH4-
200 A
Current
Source
RTD
Ref.
Adj.
COM
COM
+
- A/D
COM
200 A
Current
Source
COM
COM
F0-04RTD
Book 1 (14.2)
eDS-88
DL05 / DL06 PLCs
1-800-633-0405
Prices as of April 15, 2015. Check Web site for most current prices.
DL05/06 Option Modules
Company
Information
Control Systems
Overview
F0-04DAH-1
CLICK PLC
$144.00
Do-More
PLCs Overview
4-channel analog current output
module, high resolution
Do-More H2
PLC
Output Specifications
Do-More T1H
PLC
Number of Channels
4
Output Range
4-20mA
Resolution
16-bit, .244µA/bit
Output Type
Current sourcing at
20mA max.
16-bit, Unsigned
Int., 0–FFFF (binary) or
0–65535 (BCD)
(Both require 2 words
of V-memory)
PLC Data Format
Output value
in program mode
Load Impedance
Maximum Inductive Load
OUT
CH1
CH2
CH4
COM
4mA
COM
DirectLOGIC
DL305
COM
250-750 Ohms
COM
Allowed load type
Grounded
Maximum Inaccuracy
0.2% of range
DirectLOGIC
DL405
+24V
Productivity
Controller
Overview
0V
Maximum Full Scale
±.025% of range max.
Calibration Error (not
including offset error)
Maximum Offset Calibration ±.025% of range max.
Error
F0-04DAH-1
Productivity
3000
Universal
Field I/O
±50 ppm/ °C max.
full scale calibration
change
±10 counts
±16 count maximum
of full scale)
Linearity Error (End to End) (±0.025%
Monotonic with no
missing codes
Software
Typical User Wiring
4-20mA Output
Ch. 1
±10 LSB after 10 min.
warm-up typical
4-20mA Output
Ch. 3
.05% of Full Scale
4-20mA Output
Ch. 4
Output Settling Time
.5 ms max., 5 µs min.
(full scale change)
All Channel Update Rate
Maximum Continuous
Overload
100µs
Type of Output Protection
Electronically current
limited to 20mA or less
Internal Module Circuitry
CH1
4–20mA
current sourcing
4–20mA
current sourcing
4–20mA
current sourcing
4–20mA
current sourcing
CH2
4-20mA Output
Ch. 2
Output Stability and
Repeatability
Output Ripple
CPU
DirectLOGIC
DL205
COM
COM
Output signal at power-up
and power-down
Terminal Type (Included)
External 24VDC Power
Required
Base Power Required
(5.0V)
DirectLOGIC
DL105
CH3
COM
Maximum Crosstalk
DirectLOGIC
DL05/06
4–20mA
1 mH
Accuracy vs. Temperature
DirectLOGIC
PLCs Overview
ANALOG
CH3
CH4
COM
CH1 DAC
CH2 DAC
CH4 DAC
Communications
Appendix
Book 1
+24VDC
ISOLATED ANALOG
CIRCUIT POWER
0VDC
4mA
24VDC
Power Supply
ISOLATED ANALOG
CIRCUIT COMMON
25mA
Firmware Required
DirectSOFT Required
DL05
Version 5.20 or later
DirectSOFT32 Version 3.0c or later
DL06
Version 2.30 or later
DirectSOFT32 Version 4.0, Build 16 or later
See Wiring Solutions for
part numbers of ZIPLink
cables and connection
modules compatible with
this I/O module.
Book 1 (14.2)
www.automationdirect.com
ViewMarq
Industrial
Marquees
Other HMI
Outputs open circuit
protected
150mA
C-More Micro
HMI
CH3 DAC
SHIELD CONNECTED TO SIGNAL
SOURCE COMMON (1 OF 4 SHOWN)
Removable: D0-ACC-4
C-More
HMI
DL05 / DL06 PLCs
eDS-89
Terms and
Conditions
Prices as of April 15, 2015. Check Web site for most current prices.
DL05/06 I/O Option Modules
F0-08DAH-1
$197.00
8-channel analog current output
module, high resolution
Output Specifications
Number of Channels
8
Output Range
4-20mA
Resolution
16-bit, .244µA/bit
Output Type
Current sourcing at
20mA max.
16-bit, Unsigned
Int., 0–FFFF (binary) or
0–65535 (BCD)
(Both require 2 words
of V-memory)
PLC Data Format
Output value
in program mode
Load Impedance
OUT
ANALOG
4–20mA
CH1
CH2
CH3
CH4
COM
CH5
4mA
CH6
CH7
250-750 Ohms
Maximum Inductive Load
1 mH
Allowed load type
Grounded
Maximum Inaccuracy
0.2% of range
CH8
COM
COM
+24V
0V
F0-08DAH-1
Maximum Full Scale
±.025% of range
Calibration Error (not
maximum
including offset error)
Maximum Offset Calibration ±.025% of range
maximum
Error
Accuracy vs. Temperature
±50 ppm/ °C
maximum full scale
calibration change
Maximum Crosstalk
±10 counts
±16 count maximum
of full scale)
Linearity Error (End to End) (±0.025%
Monotonic with no
missing codes
Typical User Wiring
4-20mA Output
Ch. 1
Internal Module Circuitry
CH1
CH3
CH4
Output Stability and
Repeatability
Output Ripple
±10 counts after 10
min. warm-up typical
4-20mA Output
Ch. 3
.05% of Full Scale
4-20mA Output
Ch. 4
CH5
Output Settling Time
.5 ms max., 5 µs min.
(full scale change)
CH7
All Channel Update Rate
Maximum Continuous
Overload
100us
4-20mA Output
Ch. 5
Type of Output Protection
Electronically current
limited to 20mA or less
Output signal at power-up
and power-down
Terminal Type (Included)
External 24VDC Power
Required
Base Power Required
(5.0V)
CPU
4–20mA
current sourcing
4–20mA
current sourcing
4–20mA
current sourcing
4–20mA
current sourcing
CH2
4-20mA Output
Ch. 2
COM
4–20mA
current sourcing
4–20mA
current sourcing
4–20mA
current sourcing
4–20mA
current sourcing
CH6
CH8
Outputs open circuit
protected
4-20mA Output
Ch. 6
COM
Removable: D0-ACC-4
SHIELD CONNECTED TO SIGNAL
SOURCE COMMON (1 OF 8 SHOWN)
220mA
CH2 DAC
CH3 DAC
CH4 DAC
CH5 DAC
CH6 DAC
CH7 DAC
CH8 DAC
COM
4-20mA Output
Ch. 7
+24VDC
ISOLATED ANALOG
CIRCUIT POWER
0VDC
4-20mA Output
Ch. 8
4mA
CH1 DAC
0V
24VDC
Power Supply
25mA
Firmware Required
DirectSOFT Required
DL05
Version 5.20 or later
DirectSOFT32 Version 3.0c or later
DL06
Version 2.30 or later
DirectSOFT32 Version 4.0, Build 16 or later
See Wiring Solutions for
part numbers of ZIPLink
cables and connection
modules compatible with
this I/O module.
Book 1 (14.2)
eDS-90
DL05 / DL06 PLCs
1-800-633-0405
Prices as of April 15, 2015. Check Web site for most current prices.
DL05/06 Option Modules
Company
Information
Control Systems
Overview
F0-04DAH-2
CLICK PLC
$140.00
Do-More
PLCs Overview
4-channel analog voltage output module,
high resolution
Do-More H2
PLC
Output Specifications
Number of Channels
4
Output Range
0-10VDC
Resolution
16-bit, 152µV/bit
Output Type
Voltage sourcing/
sinking at 5mA max.
16-bit, Unsigned
Int., 0–FFFF (binary) or
0–65535 (BCD)
(Both require 2 words
of V-memory)
PLC Data Format
Output value
in program mode
Output Impedance
Load Impedance
Do-More T1H
PLC
OUT
CH1
CH2
CH4
COM
COM
COM
COM
0V
F0-04DAH-2
Productivity
3000
Universal
Field I/O
Software
Typical User Wiring
±50 ppm/ °C max.
full scale calibration
change
Voltage Output
Ch. 1
Maximum Crosstalk
±10 counts
Voltage Output
Ch. 2
missing codes
Output Stability and
Repeatability
Output Ripple
±10 counts after 10
min. warm-up typical
Output Settling Time
.5 ms max., 5 µs min.
(full scale change)
All Channel Update Rate
100µs
Maximum Continuous
Overload
Type of Output Protection
Output signal at power-up
and power-down
Terminal Type (Included)
External 24VDC Power
Required
Base Power Required
(5.0V)
.05% of Full Scale
Removable: D0-ACC-4
30mA
25mA
Internal Module Circuitry
CH1
voltage
sink / source
voltage
sink / source
voltage
sink / source
voltage
sink / source
CH2
CH3
CH4
Voltage Output
Ch. 3
COM
CH2 DAC
C-More Micro
HMI
CH3 DAC
CH4 DAC
ViewMarq
Industrial
Marquees
Other HMI
Communications
SHIELD CONNECTED TO SIGNAL
SOURCE COMMON (1 OF 4 SHOWN)
Appendix
Book 1
+24VDC
ISOLATED ANALOG
CIRCUIT POWER
0VDC
isolated analog
circuit common
24VDC
Power Supply
CPU
Firmware Required
DirectSOFT Required
DL05
Version 5.20 or later
DirectSOFT32 Version 3.0c or later
DL06
Version 2.30 or later
DirectSOFT32 Version 4.0, Build 16 or later
See Wiring Solutions for part
numbers of ZIPLink cables and
connection modules compatible
with this I/O module.
Book 1 (14.2)
www.automationdirect.com
C-More
HMI
CH1 DAC
Voltage Output
Ch. 4
Outputs current limited
to 40mA typical.
A continuous short
circuit will damage the
output.
24VDC Peak
Output Voltage
(capacitor transient
voltage suppressor)
0V
Productivity
Controller
Overview
+24V
Accuracy vs. Temperature
±16 count max.
DirectLOGIC
DL405
COM
Maximum Full Scale
±.025% of range max.
Calibration Error
(including offset error)
Maximum Offset Calibration ±.025% of range max.
Error
of full scale)
Linearity Error (End to End) (±0.025%
Monotonic with no
DirectLOGIC
DL305
COM
Maximum Capacitive Load 0.01 µF maximum
0.2% of range
(including temperature
changes)
DirectLOGIC
DL205
COM
>2000 Ohms
Maximum Inaccuracy
DirectLOGIC
DL105
CH3
0.5 Ohms typical
Grounded
DirectLOGIC
DL05/06
0–10VDC
0V
Allowed load type
DirectLOGIC
PLCs Overview
ANALOG
DL05 / DL06 PLCs
eDS-91
Terms and
Conditions
Prices as of April 15, 2015. Check Web site for most current prices.
DL05/06 I/O Option Modules
F0-08DAH-2
$186.00
8-channel analog voltage output module,
high resolution
Output Specifications
Number of Channels
8
Output Range
0-10VDC
Resolution
16-bit, 152µV/bit
Output Type
Voltage sourcing/
sinking at 5mA max.
16-bit, Unsigned
Int., 0–FFFF (binary) or
0–65535 (BCD)
(Both require 2 words
of V-memory)
PLC Data Format
Output value
in program mode
Output Impedance
Load Impedance
OUT
ANALOG
0–10VDC
CH1
CH2
CH3
CH4
COM
CH5
0V
CH6
CH7
0.5 Ohms typical
CH8
>2000 Ohms
COM
COM
Maximum Capacitive Load 0.01 µF maximum
Allowed load type
Grounded
Maximum Inaccuracy
0.2% of range
(including temperature
changes)
+24V
0V
F0-08DAH-2
Maximum Full Scale
±.025% of range
Calibration Error
maximum
(including offset error)
Maximum Offset Calibration ±.025% of range
maximum
Error
Typical User Wiring
Accuracy vs. Temperature
±50 ppm/ °C
maximum full scale
calibration change
Voltage Output
Ch. 1
Maximum Crosstalk
10 counts
Linearity Error (End to End)
±16 count maximum
(±0.025% of full scale)
Monotonic with no
missing codes
Voltage Output
Ch. 2
Output Stability and
Repeatability
Output Ripple
±10 counts after 10
min. warm-up typical
Output Settling Time
.5 ms max., 5 µs min.
(full scale change)
All Channel Update Rate
100µs
Maximum Continuous
Overload
Type of Output Protection
Output signal at power-up
and power-down
Terminal Type (Included)
External 24VDC Power
Required
Base Power Required
(5.0V)
.05% of Full Scale
Outputs current limited
to 40mA typical. A
continuous
short circuit will
damage the output.
24VDC Peak Output
Voltage
(capacitor transient
voltage suppressor)
0V
Removable: D0-ACC-4
Internal Module Circuitry
CH1
CH2
CH3
CH4
Voltage Output
Ch. 3
COM
Voltage Output
Ch. 4
CH5
Voltage Output
Ch. 5
CH7
CH6
CH8
Voltage Output
Ch. 6
COM
voltage
sink / source
voltage
sink / source
voltage
sink / source
voltage
sink / source
voltage
sink / source
voltage
sink / source
voltage
sink / source
voltage
sink / source
CH1 DAC
CH2 DAC
CH3 DAC
CH4 DAC
CH5 DAC
CH6 DAC
CH7 DAC
CH8 DAC
COM
Voltage Output
Ch. 7
+24VDC
ISOLATED ANALOG
CIRCUIT POWER
0VDC
Voltage Output
Ch. 8
SHIELD CONNECTED TO SIGNAL
SOURCE COMMON (1 OF 8 SHOWN)
24VDC
Power Supply
CPU
Firmware Required
isolated analog
circuit common
DirectSOFT Required
DL05
Version 5.20 or later
DirectSOFT32 Version 3.0c or later
DL06
Version 2.30 or later
DirectSOFT32 Version 4.0, Build 16 or later
30mA
25mA
See Wiring Solutions for part
numbers of ZIPLink cables and
connection modules compatible
with this I/O module.
Book 1 (14.2)
eDS-92
DL05 / DL06 PLCs
1-800-633-0405
Prices as of April 15, 2015. Check Web site for most current prices.
DL05/06 Option Modules
Company
Information
Control Systems
Overview
F0-2AD2DA-2 CLICK PLC
$155.00
Do-More
PLCs Overview
2-channel analog voltage input and
2-channel analog voltage output module
Do-More H2
PLC
F0-2AD2DA-2 Output Specifications
F0-2AD2DA-2 Input Specifications
Number of Channels
2, single ended
(one common)
Number of Channels
2, single ended
(one common)
Input Range
0 to 5VDC or
0 to 10VDC
(jumper selectable)
Output Range
0 to5VDC or
0 to 10VDC
(jumper selectable)
Resolution
12 bit (1 in 4096)
Resolution
12 bit (1 in 4096)
Step Response
10.0mS to 95%
of full step change
Conversion Settling Time
50eS
for full scale change
Crosstalk
1/2 count
max (-80db)*
Crosstalk
1/2 count max
(-80db)*
Active Low-pass Filtering
-3dB at 300Hz
(-12dB per octave)
Peak Output Voltage
w15VDC
(power supply limited)
Input Impedance
L20Kh
Offset Error
0.1% of range
Absolute Max Ratings
w15V
Gain Error
0.4% of range
counts (0.025%
Linearity Error (end to end) w2
of full scale) max*
counts (0.075%
Linearity Error (end to end) w1
of full scale) max*
Input Stability
w1 count*
Output Stability
w2 counts*
Gain Error
w6 counts max*
Load Impedance
2Kh min
Offset Error
w2 counts max*
Load Capacitance
0.01eF max
w0.3% at 25-C
(77-F)
w0.6% at 0 to 60--C
(32 to 140-F)
Terminal Type (Included)
Removable: F0-IOCON
Max Inaccuracy
Accuracy vs. Temperature
w50 ppm/-C typical
Accuracy vs. Temperature
w100 ppm/-C typical
Do-More T1H
PLC
DirectLOGIC
PLCs Overview
DirectLOGIC
DL05/06
DirectLOGIC
DL105
DirectLOGIC
DL205
DirectLOGIC
DL305
DirectLOGIC
DL405
Productivity
Controller
Overview
Productivity
3000
Universal
Field I/O
Software
C-More
HMI
C-More Micro
HMI
* One count in the specification table is equal to one
least significant bit of the analog data value (1 in 4096)
ViewMarq
Industrial
Marquees
Transmitter
Power Supply
+
–
Other HMI
Internal
Module
Wiring
See NOTE 1
–
+
CH1
4–wire
Voltage
Transmitter
CH2
2–wire
Voltage
Transmitter
Appendix
Book 1
+
–
1
+
IN
2
–
0V
1
OUT
2
CH 1 load
2k ohms
minimum
Resistance
Ch 1
Voltage Source
Ch 2
Voltage Source
A to D
Converter
D to A
Converter
D to A
Converter
0V
CH 2 load
2k ohms
minimum
Resistance
NOTE 1: Shields should be grounded at the signal
source.
NOTE 2: Connect all external power supply
commons.
Analog Switch
See Wiring Solutions for
part numbers of ZIPLink
cables and connection
modules compatible
with this I/O module.
Communications
V+
24V
0V
–
+
18.0–26.4VDC
Power Supply
OV
Module Supply
Book 1 (14.2)
www.automationdirect.com
DL05 / DL06 PLCs
eDS-93
Terms and
Conditions
Prices as of April 15, 2015. Check Web site for most current prices.
DL05/06 Option Modules
F0-4AD2DA-1
$192.00
4-channel analog current input
and 2-channel analog current
output module
F0-4AD2DA-1 Input Specifications
F0-4AD2DA-1 Output Specifications
Number of Channels
4, single ended
(one common)
Number of Channels
2, single ended
(one common)
Input Range
0 to 20 mA or
4 to 20 mA
(jumper selectable)
Output Range
Resolution
0 to 20 mA or
4 to 20 mA
(jumper selectable)
12 bit (1 in 4096)
Output Type
Current sourcing
Step Response
25.0 mS (typ.)
to 95%
of full step change
Resolution
12 bit (1 in 4096)
Max. Loop Voltage
30 VDC
Load/loop Power Supply
0-300 h /18-30 VDC
1/2 count max
(-80db)*
Crosstalk
dB at 40 Hz
Active Low-pass Filtering -3
(-12dB per octave)
Input Impedance
125 h w0.1%,
1/8 watt
Absolute Max Ratings
-30mA to +30 mA,
current input
Converter Type
Successive
approximation
w2 counts
Linearity Error (end to end) (0.050% of full scale)
max.*
Conversion Settling Time
400 es max.
for full scale change
Full-scale Calibration Error
w26 counts max. @
300 h load
w18 counts max.. @
250 h load
w12 counts max.. @
125 h load
Offset Calibration Error
w10 counts max.. @
300 h load
w8 counts max.. @
250 h load
w6 counts max.. @
125 h load
Terminal Type (Included)
Removable: F0-IOCON
Max.Full- scale Inaccuracy
(all errors included)
300 h load 0.4%. @
60- C
250 h load 0.3%. @
60- C
125 h load 0.2%. @
60- C
Linearity Error (end to end) w2 counts
See Wiring Solutions for
part numbers of ZIPLink
cables and connection
modules compatible
with this I/O module.
Input Stability
w1 count*
Full-scale Calibr. Error
w10 counts max.
@ 20 mA*
Offset Calibration Error
w5 counts max.
@ 0 mA*
Max Inaccuracy
w0.4% at 25-C
(77-F)
w0.85% at 0 to 60-C
(32 to 140-F)
Accuracy vs. Temp.
w100 ppm/-C typ.
Recommended Fuse
0.032 A, series 217
fast-acting,
current inputs
* One count in the specification table is equal to one
least significant bit of the analog data value (1 in 4096)
See NOTE 1
–
+
CH2
2–wire
Current
Transmitter
+
CH3
4–wire
Current
+
Transmitter
IN
–
Internal
Module
Wiring
1
2
125Ω
3
125Ω
4
125Ω
0V
125Ω
Analog Switch
–
CH1
2–wire
Current
Transmitter
+
–
+
CH4
3–wire
+
Current
–
Transmitter
1
CH 1 load
D to A
Converter
300Ω
maximum
resistance
2
CH 2 load
24V
300Ω
maximum
resistance
D to A
Converter
OUT
–
NOTE 1: Shields should be grounded at the signal source.
NOTE 2: Connect all external power supply commons.
A to D
Converter
+
OV
Transmitter
Power Supply
Book 1 (14.2)
eDS-94
DL05 / DL06 PLCs
1-800-633-0405
Prices as of April 15, 2015. Check Web site for most current prices.
DL05/06 Option Modules
Company
Information
Control Systems
Overview
F0-4AD2DA-2
$218.00
CLICK PLC
4-channel analog voltage input
F0-4AD2DA-2 Input Specifications
2-channel analog voltage output
4, single ended
Number of Channels
module
(one common)
F0-4AD2DA-2 Output Specifications
Number of Channels
2, single ended
(one common)
Do-More H2
PLC
Input Range
0 to5VDC or
0 to 10VDC
(jumper selectable)
Output Range
0 to5VDC or
0 to 10VDC
(jumper selectable)
Do-More T1H
PLC
Resolution
12 bit (1 in 4096)
Resolution
12 bit (1 in 4096)
DirectLOGIC
PLCs Overview
Step Response
10.0mS to 95%
of full step change
Conversion Settling Time
50eS
for full scale change
Crosstalk
1/2 count max
(-80db)*
Crosstalk
1/2 count max
(-80db)*
Active Low-pass Filtering
-3dB at 300Hz
(-12dB per octave)
Peak Output Voltage
w15VDC
(power supply limited)
Input Impedance
L20Kh
Absolute Max Ratings
Offset Error
0.1% of range
w15V
Gain Error
0.4% of range
count (0.025%
Linearity Error (end to end) w2
of full scale) max*
Input Stability
w1 count*
Gain Error
w6 counts max*
Offset Error
w2 counts max*
Max Inaccuracy
w0.3% at 25-C
(77-F)
w0.6% at 0 to 60--C
(32 to 140-F)
Accuracy vs. Temperature
w100 ppm/-C typical
Terminal Type (Included)
Removable: F0-IOCON
NOTE 2: Connect all external power supply commons.
2Kh minimum
0.01eF max
w50 ppm/-C typical
See Wiring Solutions for
part numbers of ZIPLink
cables and connection
modules compatible
with this I/O module.
Software
C-More
HMI
3
Other HMI
A to D
Converter
Communications
Appendix
Book 1
4
Terms and
Conditions
0V
1
Ch 1
Voltage Source
Ch 2
2
Voltage Source
D to A
Converter
D to A
Converter
0V
OUT
OV
Transmitter
Power Supply
Book 1 (14.2)
www.automationdirect.com
Universal
Field I/O
ViewMarq
Industrial
Marquees
2
+
Productivity
3000
C-More Micro
HMI
1
–
NOTE 1: Shields should be grounded at the signal source.
DirectLOGIC
DL305
Productivity
Controller
Overview
w2 counts*
IN
CH 2 load
2k ohms
minimum
Resistance
DirectLOGIC
DL205
Output Stability
Load Impedance
Load Capacitance
Accurracy vs. Temperature
Internal
Module
Wiring
CH 1 load
2k ohms
minimum
Resistance
DirectLOGIC
DL105
DirectLOGIC
DL405
Analog Switch
+
See NOTE 1
–
CH1
2–wire
+
Voltage
Transmitter
–
CH2
2–wire
Voltage
+
Transmitter
+
CH3
4–wire
Voltage
–
Transmitter
+
CH4
3–wire
+
Voltage
–
Transmitter
DirectLOGIC
DL05/06
counts (0.075%
Linearity Error (end to end) w1
of full scale) max*
* One count in the specification table is equal to one
least significant bit of the analog data value (1 in 4096)
–
Do-More
PLCs Overview
DL05 / DL06 PLCs
eDS-95
Prices as of April 15, 2015. Check Web site for most current prices.
Wiring Solutions
Wiring Solutions using the ZIPLink Wiring System
ZIPLinks eliminate the normally tedious process of wiring between
devices by utilizing prewired cables and DIN rail mount connector
modules. It’s as simple as plugging in a cable connector at either
end or terminating wires at only one end. Prewired cables keep
installation clean and efficient, using half the space at a fraction
of the cost of standard terminal blocks. There are several wiring
solutions available when using the ZIPLink System ranging from
PLC I/O-to-ZIPLink Connector Modules that are ready for field
termination, options for connecting to third party devices, GS,
DuraPulse and SureServo Drives, and specialty relay, transorb
and communications modules. Pre-printed I/O-specific adhesive
label strips for quick marking of ZIPLink modules are provided
with ZIPLink cables. See the following solutions to help determine
the best ZIPLink system for your application.
Solution 1: DirectLOGIC I/O Modules to ZIPLink
Connector Modules
When looking for quick and easy I/O-to-field termination, a ZIPLink
connector module used in conjunction with a prewired ZIPLink cable,
consisting of an I/O terminal block at one end and a multi-pin
connector at the other end, is the best solution.
Using the PLC I/O Modules to ZIPLink Connector
Modules selector tables located in this section,
1. Locate your I/O module/PLC.
2. Select a ZIPLink module.
3. Select a corresponding ZIPLink cable.
Solution 2: DirectLOGIC I/O Modules to 3rd Party
Devices
For connecting I/O to another device within close proximity of the
I/O modules, no extra terminal blocks are necessary when using the
ZIPLink Pigtail Cables. ZIPLink Pigtail Cables are prewired to an I/O
terminal block with color-coded pigtail with soldered-tip wires on the
other end.
Solution 3: GS Series and DuraPulse Drives
Communication Cables
Need to communicate via Modbus RTU to a drive or a
network of drives?
Using the I/O Modules to 3rd Party Devices selector
tables located in this section,
1. Locate your PLC I/O module.
2. Select a ZIPLink pigtail cable that is compatible
with your 3rd party device.
Using the Drives Communication selector tables located in
this section,
1. Locate your drive and type of communications.
2. Select a ZIPLink cable and other associated hardware.
ZIPLink cables are available in a wide range of
configurations for connecting to PLCs and SureServo,
SureStep, Stellar soft starters and AC drives. Add a ZIPLink
communications module to quickly and easily set up a
multi-device network.
Book 1 (14.2)
eDS-68
DL05 / DL06 PLCs
1-800-633-0405
Prices as of April 15, 2015. Check Web site for most current prices.
Wiring Solutions
Company
Information
Control Systems
Overview
CLICK PLC
Solution 4: Serial Communications Cables
ZIPLink offers communications cables for use with DirectLOGIC, CLICK,
and Productivity3000 CPUs, that can also be used with other communications devices. Connections include a 6-pin RJ12 or 9-pin, 15-pin and
25-pin D-sub connectors which can be used in conjunction with the RJ12
or D-Sub Feedthrough modules.
Using the Serial Communications Cables selector
table located in this section,
1. Locate your connector type.
2. Select a cable.
Do-More
PLCs Overview
Do-More H2
PLC
Do-More T1H
PLC
DirectLOGIC
PLCs Overview
DirectLOGIC
DL05/06
DirectLOGIC
DL105
DirectLOGIC
DL205
DirectLOGIC
DL305
Solution 5: Specialty ZIPLink Modules
For additional application solutions, ZIPLink modules are available in
a variety of configurations including stand-alone relays, 24VDC and
120VAC transorb modules, D-sub and RJ12 feedthrough modules,
communication port adapter and distribution modules, and SureServo
50-pin I/O interface connection.
Using the ZIPLink Specialty Modules selector table
located in this section,
1. Locate the type of application.
2. Select a ZIPLink module.
DirectLOGIC
DL405
Productivity
Controller
Overview
Productivity
3000
Universal
Field I/O
Software
C-More
HMI
C-More Micro
HMI
ViewMarq
Industrial
Marquees
Other HMI
Solution 6: ZIPLink Connector Modules to 3rd Party
Devices
If you need a way to connect your device to terminal blocks without all
that wiring time, then our pigtail cables with color-coded soldered-tip
wires are a good solution. Used in conjunction with any compatible
ZIPLink connector modules, a pigtail cable keeps wiring clean and
easy and reduces troubleshooting time.
Communications
Using the Universal Connector Modules and Pigtail
Cables table located in this section,
1. Select module type.
2. Select the number of pins.
3. Select cable.
Book 1 (14.2)
www.automationdirect.com
DL05 / DL06 PLCs
eDS-69
Appendix
Book 1
Terms and
Conditions
Prices as of April 15, 2015. Check Web site for most current prices.
PLC I/O Modules to ZIPLink
Connector Modules - DL05/06
DL05/06 PLC Output Module ZIPLink Selector
PLC
ZIPLink
DL05/06 PLC Input Module ZIPLink Selector
PLC
ZIPLink
Input
Module
# of
Terms
Part
Component Module
No.
Cable Part
No.
Output
Module
D0-10ND3
D0-10ND3F
13
Feedthrough
ZL-RTB20
ZL-D0-CBL13 *
D0-10TD1
13
13
Feedthrough
ZL-RTB20
ZL-D0-CBL13 *
Feedthrough
ZL-RTB20
ZL-D0-CBL24 *L
D0-16TD1
24
Sensor
ZL-LTB16-24
ZL-D0-CBL24 *L
Feedthrough
ZL-RTB20
ZL-D0-CBL10 *
D0-10TD2
13
D0-16ND3
24
F0-08NA-1
10
DL05/06 PLC Combo In/Out Module ZIPLink Selector
PLC
ZIPLink
Combo
Module
# of Terms Component
Module Part Cable Part No.
No.
D0-07CDR
10
Feedthrough
ZL-RTB20
ZL-D0-CBL10 *
D0-08CDD1
13
Feedthrough
ZL-RTB20
ZL-D0-CBL13 *
D0-16TD2
# of Terms Component
F0-04AD-1
8
Feedthrough
Module
Cable
ZL-RTB20
ZL-D0-CBL8 *
F0-04AD-2
8
Feedthrough
ZL-RTB20
ZL-D0-CBL8 *
F0-08ADH-1
13
Feedthrough
ZL-RTB20
ZL-D0-CBL13 *
F0-08ADH-2
13
Feedthrough
ZL-RTB20
ZL-D0-CBL13 *
F0-04DAH-1
13
Feedthrough
ZL-RTB20
ZL-D0-CBL13 *
F0-08DAH-1
13
Feedthrough
ZL-RTB20
ZL-D0-CBL13 *
F0-04DAH-2
13
Feedthrough
ZL-RTB20
ZL-D0-CBL13 *
F0-08DAH-2
13
Feedthrough
ZL-RTB20
ZL-D0-CBL13 *
F0-2AD2DA-2
8
Feedthrough
ZL-RTB20
ZL-D0-CBL8
F0-4AD2DA-1
8
Feedthrough
ZL-RTB20
ZL-D0-CBL8 *
8
Feedthrough
ZL-RTB20
ZL-D0-CBL8 *
F0-4AD2DA-2
F0-04RTD2
F0-04THM2
Matched Only
See Note 2
Matched Only
See Note 2
24
Part Cable Part
Component Module
No.
No.
Feedthrough
ZL-RTB20
ZL-D0-CBL13 *
Feedthrough
ZL-RTB20
ZL-D0-CBL24 *
Fuse
ZL-RFU203
ZL-D0-CBL24 *
Relay (sinking)
ZL-RRL16-24-1
ZL-D0-CBL24 *
Feedthrough
ZL-RTB20
ZL-D0-CBL13 *
Feedthrough
ZL-RTB20
ZL-D0-CBL24 *
Fuse
ZL-RFU203
ZL-D0-CBL24 *
Relay (sourcing) ZL-RRL16-24-2
ZL-D0-CBL24 *
D0-08TR
10
Feedthrough
ZL-RTB20
ZL-D0-CBL10 *
F0-04TRS1
13
Feedthrough
ZL-RTB20
ZL-D0-CBL13 *
DL05/06 PLC Fixed I/O ZIPLink Selector
PLC
ZIPLink
DL05/06 PLC Analog Module ZIPLink Selector
PLC
ZIPLink
Analog
Module
# of Terms
PLC
DL05
DL06
# of Terms
18
Part Cable Part
Component Module
No.
No.
Feedthrough
ZL-RTB20
ZL-D05-CBL18 *
20 (Input side only) Feedthrough
ZL-RTB20
ZL-D06X-CBL20 *
20 (Output side only) Feedthrough
ZL-RTB20
ZL-D06Y-CBL20 *
* Select the cable length by replacing the * with: Blank = 0.5m, -1 = 1.0m,
or -2 = 2.0m.
1 Caution: The F0-04TRS relay outputs are derated not to exceed 2A per point
when used with the ZIPLink wiring system.
2 These modules are not supported by the ZIPLink wiring system.
3 Note: Fuses (5 x 20 mm) are not included. See Edison Electronic Fuse section
for (5 x 20 mm) fuse. S500 and GMA electronic circuit protection for fast-acting
maximum protection. S506 and GMC electronic circuit protection for time-delay
performance. Ideal for inductive circuits.
To ensure proper operation, do not exceed the voltage and current rating of
ZIPLink module. ZL-RFU20 = 2A per circuit; ZL-RFU40 = 400 mA per circuit.
Note: ZIPLink Connector Modules and ZIPLink Cables
specifications are in the ZIPLink catalog section.
Book 1 (14.2)
eDS-70
DL05 / DL06 PLCs
1-800-633-0405
Prices as of April 15, 2015. Check Web site for most current prices.
Power Budgeting for the DL06
D0-06xx
Power supplied
D0-06xx-D
24 VDC (mA)
1500mA
300mA
2000mA
200mA
1500mA
none
DL06 Base Unit Power Required
Part Number 5 VDC (mA)
24 VDC (mA)
D0-06AA
800mA
none
D0-06AR
900mA
none
D0-06DA
800mA
none
For power budgeting, start by considering
the power supplied by the base unit. All
DL06 PLCs supply the same amount of 5
VDC power. Only the AC units offer 24
VDC auxiliary power.
D0-06DD1
600mA
280mA*
D0-06DD2
600mA
none
D0-06DR
950mA
none
D0-06DD1-D
600mA
none
Be aware of the trade-off between 5 VDC
power and 24 VDC power. The amount of
5 VDC power available depends on the
amount of 24 VDC power being used,
and the amount of 24 VDC power available depends on the amount of 5 VDC
power consumed. Determine the amount
of internally supplied power from the table
to the right.
D0-06DD2-D
600mA
none
D0-06DR-D
950mA
none
* Only if auxiliary 24VDC power is connected to V+ terminal.
DL06 Power Consumed
by Other Devices
Part Number
5 VDC (mA)
24 VDC (mA)
D0-06LCD
50mA
none
D2-HPP
200mA
none
DV-1000
C-more
Micro-Graphic
150mA
none
210mA
none
Power Budgeting Example
5VDC power 24VDC power
(mA)
(mA)
Power Source
A
D0-06DD1
(select row A or B) B
1500mA
300mA
2000mA
200mA
Power required by option
modules
power 24VDC power
Current Required 5VDC
(mA)
(mA)
Next, subtract the amount of power
required by the option modules you are
planning to use. Again, remember to
subtract both 5 VDC and 24 VDC.
If your power budget analysis shows
surplus power available, you should have
a workable configuration.
DL05/06 Power Consumed
by Option Modules
DL06 Power Supplied by Base Units
Part Number 5 VDC (mA)
Power is supplied from two sources: the
internal base unit power supply and, if
required, an external supply (customer
furnished). The D0-06xx (AC powered)
PLCs supply a limited amount of 24 VDC
power. The 24 VDC output can be used to
power external devices.
Because of the different I/O configurations available in the DL06 family, the
power consumed by the base unit itself
varies from model to model. Subtract the
amount of power required by the base unit
from the amount of power supplied by the
base unit. Be sure to subtract 5 VDC and
24 VDC amounts.
Control Systems
Overview
CLICK PLC
The DL06 has four option module slots.
To determine whether the combination
of modules you select will have sufficient
power, you will need to perform a power
budget calculation.
Power required by base
unit
Company
Information
D0-06DD1
600mA
280mA*
D0-16ND3
35mA
0
D0-10TD1
150mA
0
D0-08TR
280mA
0
F0-4AD2DA-1
100mA
0
D0-06LCD
50mA
0
Total Used
Remaining
1215mA
280mA
A
285mA
20mA
B
785mA
note 1
Part Number 5 VDC (mA) 24 VDC (mA)
130mA
none
D0-07CDR
100mA
none
D0-08CDD1
280mA
none
D0-08TR
35mA
none
D0-10ND3
35mA
none
D0-10ND3F
150mA
none
D0-10TD1
150mA
none
D0-10TD2
35mA
none
D0-16ND3
200mA
none
D0-16TD1
200mA
none
D0-16TD2
250mA
none
F0-04TRS
5mA
none
F0-08NA-1
50mA
none
F0-04AD-1
75mA
none
F0-04AD-2
25mA
25mA
F0-08ADH-1
25mA
25mA
F0-08ADH-2
25mA
150mA
F0-04DAH-1
25mA
220mA
F0-08DAH-1
25mA
30mA
F0-04DAH-2
25mA
30mA
F0-08DAH-2
50mA
30mA
F0-2AD2DA-2
100mA
40mA
F0-4AD2DA-1
100mA
none
F0-4AD2DA-2
70mA
none
F0-04RTD
30mA
none
F0-04THM
45mA
none
D0-DEVNETS
530mA
none
H0-PSCM
250mA
none
H0-CTRIO2
300mA
none
H0-ECOM100
1mA
none
F0-08SIM
250 mA
none
D0-DCM
150 mA
none
F0-CP128
1 mA
none
F0-08SIM
Do-More H2
PLC
Do-More T1H
PLC
DirectLOGIC
PLCs Overview
DirectLOGIC
DL05/06
DirectLOGIC
DL105
DirectLOGIC
DL205
DirectLOGIC
DL305
DirectLOGIC
DL405
Productivity
Controller
Overview
Productivity
3000
Universal
Field I/O
Software
C-More
HMI
C-More Micro
HMI
ViewMarq
Industrial
Marquees
Other HMI
Communications
Appendix
Book 1
Terms and
Conditions
* Auxiliary 24 VDC used to power V+ terminal of D0-06DD1 sinking outputs.
Note 1: If the PLC’s auxiliary 24 VDC power source is used to power
the sinking outputs, use power choice A, above.
Book 1 (14.2)
www.automationdirect.com
Do-More
PLCs Overview
DL05 / DL06 PLCs
eDS-29