EWHA8, 14*1H, 2H
With FLEXI-GUARD
®
Installation/Care/Use Manual
USES HFC-134A REFRIGERANT
34 (SEE FIG. 5)
7
SEE FIG. 3
8 (SEE FIG. 4)
28
29
30
17, 18, 19, 20
22, 23, 24,
25, 45, 46
15, 16
21
51
52
13
33
50
14
31, 32
27, 41, 42, 47
54
40, 53
26
43
FIG. 1
PAGE 1
98021C (Rev. A - 12/03)
98021C (Rev. A - 12/03)
PAGE 2
E = INSURE PROPER VENTILATION BY MAINTAINING 4" (102mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 4" (102mm) (MÍN.) DE HOLGURA ENTRE LA
REJILLA DE VENTILACIÓN DEL MUEBLE Y LA PARED
ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 4" (102mm) (MIN.) ENTRE LES ÉVENTS DE LENCEINTE ET LE
MUR.
F = POWER CORD 4 FEET (1219mm) LONG
CABLE ELÉCTRICO DE 4 PIE (1219mm), DE LARGO
CORDON DALIMENTATION 4' (1219mm)
G = PLUMBING ROUGH-IN CAN BE LOCATED ANYWHERE WITHIN THIS AREA.
SE PUEDE COLOCAR EL DESBASTE DE LA TUBERÍA EN CUALQUIER LUGAR DENTRO DE ESTA ÁREA.
ON PEUT PLACER LA TUYAUTERIE DANS CETTE RÉGION.
FIG. 2
LEGEND/LEYENDA/LÉGENDE
A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB OUT 1-1/2 IN. (38mm)
FROM WALL SHUT OFF BY OTHERS
SE RECOMIENDA UBICAR EL TUBO CORTO DE CONEXIÓN AL TUBO DE COBRE SIN CHAPAR DE 3/8" DE DIÁM. EXT. A 1-1/2"
(38 mm) FUERA DE LA LLAVE DE PASO EN LA PARED COLOCADA POR TERCEROS.
EMPLACEMENT RECOMMANDÉ D'ALIMENTATION EN EAU PAR TUBE EN CUIVRE NON PLAQUÉ DE 3/8 PO. (9,5 mm) D.E.
CONNECTANT UNE TUYAUTERIE DE 1-1/2 PO. (38 mm) DEPUIS LE ROBINET D'ARRÊT FOURNI PAR D'AUTRES.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4 O.D. DRAIN
UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA, DE 1¼ DE DIÁMETRO.
EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/4" DE SORTIE DEAU.
C = 1-1/4 TRAP NOT FURNISHED
PURGADOR DE 1¼ NO PROPORCIONADO
SIPHON 1-1/4 NON FOURNI
D = ELECTRICAL OUTLET LOCATION
UBICACIÓN DE LA TOMA DE ELECTRICIDAD
EMPLACEMENT DE LA PRISE DE COURANT
FINISHED FLOOR
PISO ACABADO
PLANCHER FINI
33" (838mm) RECOMMENDED
HEIGHT FOR CHILDREN
ALTURA RECOMENDADA PARA LOS
NIÑOS 33" (838 mm)
HAUTEUR RECOMMANDÉE POUR
LES ENFANTS 33" (838mm)
40" (1016mm) RECOMMENDED
HEIGHT FOR ADULTS
ALTURA RECOMENDADA PARALOS
ADULTOS 40" (1016 mm)
HAUTEUR RECOMMANDÉE POUR
LES ADULTES 40" (1016mm)
EWHA8, 14*1H, 2H
EWHA8, 14*1H, 2H
Stream height is factory set at 35 PSI. If supply pressure varies
greatly from this, remove Items 1 & 2 and adjust screw on
Item 4. Clockwise adjustment will raise stream and counterclockwise adjustment will lower stream. For best adjustment,
stream should hit basin approximately 6-1/2" (165mm) from
bubbler.
10
9
8
11
1
BASIN
2
3
12
4
NOTE:
WHEN INSTALLING REPLACEMENT
BUBBLER AND PEDESTAL, TIGHTEN
NUT (ITEM 12) ONLY TO HOLD
PARTS SNUG IN POSITION.
DO NOT OVER TIGHTEN.
5
BASIN
6
FIG. 3
FIG. 4
WIRING DIAGRAM
35
This Drawing is merely for illustrating the
components of the electrical system.
38
37
36
39
FIG. 5
PAGE 3
98021C (Rev. A - 12/03)
EWHA8, 14*1H, 2H
PARTS LIST 115V
ITEM NO.
PART NO.
1
2
3
4
5
6
7
40089C
40048C
15005C
61313C
40169C
50986C
21541C
21539C
56073C
40322C
56011C
55997C
75580C
31513C
36132C
66417C
66432C
21516C
31490C
31491C
30664C
27681C
70018C
66202C
66203C
35762C
35775C
31027C
35840C
31797C
35768C
194243901550
55996C
45448C
56092C
66229C
66445C
66505C
66506C
28427C
36101C
36204C
45820C
40597C
33659000
51543C
40596C
70921C
70606C
50368C
70750C
70682C
70683C
35843C
35844C
50005C
100322740560
15009C
70793C
28438C
28445C
66736C
75666C
70817C
8
9
10
11
12
13
14
15
16
17
18
19
20
21
*22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
PRINTED IN U.S.A.
230V 50/60 Hz
DESCRIPTION
Cover
Button
Regulator Retaining Nut
Regulator
Hex Nut
Regulator Holder
Basin
Basin (GF)
Bubbler Assy
Orifice Assy
Housing Assy
Pedestal
Bubbler Locknut
Cold Control
Power Cord
Condenser (8 GPH)
Condenser (14 GPH)
Fan Shroud
Fan Motor (8 GPH)
Fan Motor (14 GPH)
Fan Blade
Fan Bracket
Fan Blade Nut
Drier (8 GPH)
Drier (14 GPH)
Compressor Serv. Pak 8 GPH
Compressor Serv. Pak 14 GPH
Overload/Relay Assy. (8 GPH)
Overload (14 GPH)
Relay Cover (8 GPH)
Relay Cover (14 GPH)
Electrical Shield
Strainer
Tailpipe/Vacuum Break
Poly Tubing (Cut To Length)
Heat Exchanger (8 GPH)
Heat Exchanger (14 GPH)
Evaporator (8 GPH)
Evaporator (14 GPH)
Hot Tank Switch Bracket
Hot Tank Switch
Hot Tank Assy
Hot Valve Assy
Gooseneck
Body Gasket
Handle
Shroud
Mounting Nut
Plug-Drain
Receptor-Drain
Clamp-Hose
Tee - 1/4 x 1/4 x 1/4
Union - 1/4
Relay (14 GPH)
Capacitor (14 GPH)
Gasket - Drain
Gasket (GF)
Nipple - Bubbler (GF)
Elbow - 1/4 x 90°
Bracket - Hot Tank Hold
Bracket - Hot Tank Mounting
Tube - 5/16 to 1/4 Drain
Nut - Drain 5/16" Compression
Elbow - 1/4 Stem x 90° (NS)
ITEM NO.
PART. NO.
14
17
22*
36131C
31430C
35789C
35764C
36168C
31028C
35768C
66452C
36205C
36164C
35826C
23
24
29
33
45
-
DESCRIPTION
Power Cord (8 & 14 GPH)
Fan Motor (8 & 14 GPH)
Compressor Serv. Pak (8 GPH)
Compressor Serv. Pak (14 GPH)
Overload (8 GPH)
Overload/Relay Assy. (14 GPH)
Relay Cover (8 & 14 GPH)
Heat Exchanger (8 GPH)
Hot Tank Assy (8 & 14 GPH)
Relay (8 GPH)
Power Inlet
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE
WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.
NOTE: All correspondence pertaining to any of the above water
coolers or orders for repair parts MUST include Model No. and Serial
No. of cooler, name and part number of replacement part.
Glass Filler Shown
for Reference Only
48
49
FIG. 7
COLOR TABLE
LEFT PANEL
RIGHT PANEL
(w/o hole)
RIGHT PANEL
(w/ hole)
FRONT PANEL
Gray Beige
Almond
Stainless Steel
Sandalwood
Granite
Light Gray Granite
20638C
21464C
20640C
21462C
27171C
27172C
21526C
21530C
21527C
21528C
27192C
N/A
20639C
21465C
20641C
21463C
27174C
27175C
20675C
20676C
20672C
21454C
27150C
21455C
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640.
ELKAY MANUFACTURING COMPANY 2222 CAMDEN COURT OAK BROOK, IL 60523 630.574.8484
98021C (Rev. A - 12/03)
PAGE 4
">