Cross Technologies 2017-74 Up+Downconverter, 70 MHz 6.7-7.0 GHz, 70 MHz 4.5-4.8 GHz Data Sheet
PDF
Download
Document
Advertisement
Advertisement
DATA SHEET CROSS TECHNOLOGIES, INC. REV. E 10/27/10 2017-74 Up/Downconverter, C-Band The 2017-74 C-band Up/Downconverter converts 70 MHz to 6.7 - 7.025 GHz (Up) and 4.5 - 4.8 GHz to 70 MHz (Down) in 0.125 MHz steps with low group delay and flat frequency response. A common synthesized local oscillator (LO) provides frequency selection for the Up and Down converter simultaneously. Multi-function push button switches select the RF frequency, gain, and other parameters. Front panel LEDs provide indication of DC power (green), PLL alarm for up and downconverters (red), remote operation (yellow), and Upconverter mute (yellow). Gain can be manually controlled over a 0 to +30 dB range for the upconverter and over a +30 to +50 dB range for the downconverter as adjusted by the front panel multi-function push-button switches. Remote operation allows selection of frequency and gain. Parameter selection and frequency and gain settings appear on the LCD display. Connectors are BNC female for IF and the optional external reference input and output, and N female for RF. A high stability (±0.01ppm) option is also available. It is powered by a 100-240 ± 10% VAC power supply and housed in a 1.75” X 19” X 16” 1RU chassis. MODEL 2017 DOWNCONVERTER UPCONVERTER U F=6850.000 G=+10 D F=4600.000 G=+30 UP/DOWNCONVERTER MENU CROSS TECHNOLOGIES INC. EXECUTE ALARM REMOTE POWER MUTE ALARM Front Panel EQUIPMENT SPECIFICATIONS* ----------UPCONVERTER---------Input Characteristics (IF) Impedance/Return Loss 75 /18 dB Frequency 70 ± 18 MHz Level -40 to -10 dBm Output Characteristics (RF) Impedance/Return Loss 50/14 dB Frequency 6.7 - 7.025 GHz Level -20 to 0 dBm 1dB compression +10 dBm Channel Characteristics Gain range (adjustable) -10 to +20 dB, 1dB steps Frequency Sense Non-inverting --------UP and DOWNCONVERTER-------Channel Characteristics Frequency Response ±1.5 dB, in band; ±0.5 dB, 36 MHz BW Spurious Response <-50 dBC Group Delay, max 0.015 ns/MHz2 parabolic; 0.05 ns/MHz linear; 1 ns ripple Synthesizer Characteristics Frequency Accuracy ±0.01 ppm Frequency Step 1MHz (125 / 100 KHz frequency steps option X / X1 10 MHz In/Out Level 3 dBm ± 3 dB (option E) ---------DOWNCONVERTER--------Input Characteristics (RF) Impedance/Return Loss 50 /14 dB Frequency 4.5 - 4.8 GHz Noise Figure, max. 15 dB (max gain) Level -60 to -30 dBm 1dB compression -10 dBm (min gain) Output Characteristics (IF) Impedance/Return Loss 75/18 dB Frequency 70 ± 18 MHz Output Level Range -10 dBm to 0 dBm 1dB compression +10 dBm Channel Characteristics Gain range (adjustable) +30 to +50 dB Image Rejection > 50 dB, min Frequency Sense Non-inverting Available Options E - External 10 MHz ref with RF insertion Phase Noise @ Freq 100 Hz 1kHz 10kHz 100kHz 1 MHz O - Frequency Reference Offset Adjust dBC/Hz -60 -70 -80 -90 -100 M&C Remote Interfaces: Controls, Indicators Q - RS485 Freq/Gain Selection direct readout LCD; pushbutton switches or remote selection W8 - Ethernet w/Web Browser Power; Alarm; Remote Green LED; Red LED; Yellow LED W18 - Ethernet w/Web & SNMP Remote RS232C, 9600 baud (options RS485/Ethernet, Q / W8,W18) T - Temperature Sensor Other X - 125 KHz frequency steps RF Connector N (female) X1 - 100 KHz frequency steps IF Connector BNC (female) 10 MHz Connectors BNC (female), 50/75 (option E) Connectors/Impedance Alarm/Remote Connector DB9 - NO or NC contact closure on Alarm M - 50 N-type (RF), 50 BNC (IF) Size 19 inch, 1RU standard chassis 1.75”high X 16.0” deep Power 100-240 ± 10% VAC, 47-63 Hz, 45 watts max *10˚C to 40˚C; Specifications subject to change without notice CROSS TECHNOLOGIES, INC. 6170 Shiloh Road, Alpharetta, Georgia 30005 770-886-8005, FAX 770-886-7964 www.crosstechnologies.com ">
Advertisement