The marine branch office of Daikin Europe N.V., named
Daikin Europe N.V. Hamburg Marine Office is located in
the heart of one of the biggest harbour towns in
the entire Europe. Through this decision,
Daikin Europe N.V. aims to establish a firm basis to
further increase its presence in the European Marine
A/C market. The portfolio of products are focused
on Marine application, such as Daikin - Packaged Marine
Air conditioners, Chillers and DX- units in accordance
to most of the well known classification societies
for which Daikin Europe N.V. Hamburg Marine Office is
your competent partner.
274
USDP*GC / USDN*HA
Daikin Marine Type
Deck Units
ūū Energy saving
ūū Compact design
ūū Refrigerants R-404A - R-407C
ūū Economical maintenance
ūū Easy installation
ūū Hermetic scroll compressor
ūū Minimum piping and field work required
ūū High performance reliability
ūū Lesser refrigerant volum with leak proof hermetic
structure
ūū High static pressure fan facilitates the use of long
ducts
ūū Quiet, less vibration operation makes
it suitable
for installation in accomodation areas
Optional customized modifications:
ūū Remote controls
ūū Electrical heater
ūū Data bus interfaces
ūū Air plenum or duct connection
ūū Higher external static pressure
ūū Cooling water regulating valve
ūū Higher air volume
USP~HR1 / USP~H
Daikin Marine Type
Packaged Series
ūū Excellent durability
ūū Hermetic scroll compressor
ūū Light weight design
ūū Refrigerants: R-404A - R-407C
ūū Resilient structure specially designed for marine
applications
ūū Abundant modification parts assures various
applications
ūū Wide operation range
ūū Easy transportation and installation
ūū Energy-saving
ūū Complete set of spare parts provided
for certain models
Optional customized modifications:
ūū Remote controls
ūū Electrical heater
ūū Data bus interfaces
ūū Air plenum or duct connection
ūū Higher external static pressure
ūū Cooling water regulating valve
ūū Higher air volume
USF*J(A)
Daikin Marine Type
Galley Series
ūū Respond to a wide temperature range
ūū High efficient operation
ūū Outstanding durable design
ūū Easy transportation and installation
ūū Excellent performance reliability
ūū Spare parts are provided as standard accessories
ūū Hermetic scroll compressor
ūū High static pressure system
ūū R-404A
Optional customized modifications:
ūū Remote controls
ūū Electrical heater
ūū Data bus interfaces
ūū Air plenum or duct connection
ūū Higher external static pressure
ūū Cooling water regulating valve
ūū Higher air volume
RHSD~A / RKS~FR Unit
Daikin Marine Type
Small Size Condensing
RHSD-A (R-134a):
ūū A semi-hermetic reciprocating compressor
with proven reliability
ūū Saved maintenance work around compressor
(without V belts & shaft seal)
RKS-FR (R-404A):
ūū An open type reciprocating compressor
of optimum design for R-404A
ūū Equal installation & maintenance as R-22
For more information, visit http://www.daikineurope.com/industrial/applications/marine
275
Daikin chillers offer the ultimate in reliability and
flexibility — a reflection of the advanced technology
inherent within them. Daikin chillers represent the sure
and safe route to a comfortable environment and a
process cooling solution that is clean and consistent.
276
Chillers
Why choose Daikin chillers
278
Products overview air cooled and condensing units
282
Products overview - water cooled
and condenserless units
284
Air cooled chillers (Cooling only)
EWAQ-ADVP
EWAQ-ACV3/ACW1
EWAQ-BAWN/BAWP
EWAQ-EEWAQ-FEWAQ-GZ
EWAD-EEWAD-DEWAD-CEWAD-CZ
EWAD-CF
NEW EWAD-TZ
286
287
288
290
292
296
298
300
308
314
316
318
Air cooled chillers (Heat pump)
EWYQ-ADVP
EWYQ-ACV3/ACW1
EWYQ-BAWN/BAWP
NEW SEHVX-AAW/SERHQ-AAW1
EWYQ-FEWYQ-GZ
EWYD-BZ
324
325
326
327
328
330
332
Air cooled condensing unit
ERAD-E-
Water cooled chillers
EWWQ-BEWWP-KBW1N
EWWD-GEWWD-IEWWD-JEWWD-H-
336
338
340
342
344
345
Condenserless chillers
EWLP-KBW1N
EWLD-JEWLD-GEWLD-I-
346
347
348
349
Water cooled centrifugal chillers
EWWD-FZXS
DWSC / DWDC
350
351
334
For more information on Options & Accessories,
please refer to page 456 of this catalogue.
277
ARGUE CARDS
Daikin chillers
Why choose Daikin chillers?
The simple answer is that, as the market leaders, the performance of our equipment is second to none.
From the smallest chillers to the very largest, our quality control and attention detail is absolute. Our
systems have the most advanced technologies, deliver the highest energy efficiencies and lowest
running costs, and are the gold standard for reliability and performance.
Benefits for the installer
› Plug & play solutions
› Maximum serviceability
› Ideal solutions for retrofit projects
Benefits for the consultant
› Energy efficient solutions without compromising
on reliability and performance
› Latest technology embedded in all our products
Benefits for the end user
› Remarkable savings on running costs
› “Green” solutions to preserve the environment
› Eurovent and AHRI certification
278
The widest and most flexible chiller portfolio
The highest efficiency for every installation
› From the smallest mini chiller for residential use to the largest
chiller for district cooling
› Tailor made solutions based on the most advanced technologies
› The lowest total cost of ownership and fast payback time
› Environmental friendly solutions
Quality and reliability
Worldwide experience in chiller design
and manufacturing
› World’s most advanced facilities for air conditioning research and
development: the Applied Development Center in Minneapolis,
Minnesota
› Inhouse development and manufacturing of chiller main
components (compressors, fans, condenser coils, software, etc...)
› Daikin’s integrated zero defect policy ensures quality of
components and finished products
› Each Daikin chiller is factory run-tested and subjected to quality
audit before shipment
Marketing tool
The chiller selection software can be accessed via
http://extranet.daikineurope.com/en/software/
downloads/default.jsp
279
Chillers
PRINTING COMPANY
CHILLER
AIR COOLED CHILLER
ICE RINK

Chillers
EWYQGZXR
DATA CENTER
PROCESS COOLING
ICE RINK

Air cooled and condensing units
Products overview
Extra low
Reduced
Low
Standard
Sound version
High ambient
Premium
High
Standard
Efficiency version
Screw
Scroll
Swing
Free cooling
Inverter
Refrigerant
Compressor
Cooling only

EWAQ~ADVP
R-A
y
EWAQ~ACV/ACW
R-A
y
EWAQ~BA*
R-A
y
EWAQ~E-
R-A
y
EWAQ~F-
R-A
y
EWAQ~GZ
R-A
EWAD~E-
R-a
y
y
EWAD~D-
R-a
y
y
y
EWAD~C-
R-a
y
y
y
EWAD~CZ
R-a
EWAD~CF
R-a
EWAD~TZ
NEW
R-a
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
Heat pump

EWYQ~ADVP
R-A
y
EWYQ~ACV/ACW
R-A
y
EWYQ~BA*
R-A
R-A
SEHVX-AAW
SERHQ-AAW
NEW
y
y
y
y
y
y
y
y
y
y
y
y
y
EWYQ~F-
R-A
EWYQ~GZ
R-A
y
EWYD~BZ
R-a
y
y
y
y
y
y
y
y
y
y
y
y
282
y
y
y
Condensing unit
ERAD~E-
y

R-a
y
y
y
y
Air cooled and condensing units
Cooling capacity (kW)
Heating capacity (kW)
.


,
,
.~.
.~.
.~.
~
~
~
~
~
~,
~,
~,
~
.


,
,

,
,
.~.
5.6~8.2
.~.
.~.
.~.
.~.
.~.
.~.
~
~
~
~
~
~
.

~
283
Water cooled and condenserless units
Products overview
Sound version
Standard
High
Standard
Efficiency version
Centrifugal
Screw
Scroll
Inverter
Refrigerant
Compressor
Water cooled chillers (Cooling only & Heating only)
y
y
y
y
y
R-134a
y
y
y
y
EWWD~I-
R-134a
y
y
y
y
EWWD~H-
R-134a
y
y
y
R-410A
y
y
y
EWWP~KBW1N
R-407C
EWWD~J-
R-134a
EWWD~G-
y
Water cooled chillers (Cooling only)
EWWQ~B-
y
Condenserless chillers
y
y
y
y
y
R-134a
y
y
y
R-134a
y
y
y
EWLP~KBW1N
R-407C
EWLD~J-
R-134a
EWLD~GEWLD~I-
y
Water cooled centrifugal chillers
EWWD~FZ
R-134a
y
y
y
y
DWSC
DWDC
R-134a
optional
y
y
y
6,000 RT
CENTRIFUGAL
R-134a
y
y
y
284
Water cooled and condenserless units
Cooling capacity (kW)
Heating capacity (kW)
0
17.5
200
500
1,000
2,000 21800
1,000
2,000 21800
1,000
2,000 21800
1,000
2,000 21800
12.9~194
16.7~249
120~568
142~681
165~602
209~743
332~1,503
424~1,951
368~1,212
454~1,488
0
17.5
200
500
379~2,156
0
17.5
200
500
12.1~62.4
110~529
160~524
315~1,433
0
17.5
200
500
113~1,054
300~4,500
600~9,000
[ 2 x 10,900 ]
21,800
285
EWAQ-ADVP
Air cooled mini inverter chiller
 Inverter technology to ensure low sound values and
leader-of-class ESEER
 Wide operating range
 Easy ‘plug and play’ installation
 Single phase power supply and low starting currents make the
unit ideal for residential applications
 Built-in hydronic module: no buffer tank required and a standard
pump and main switch are included
EWAQ-ADVP
Cooling only
Cooling capacity
Power input
Capacity control
EER
Dimensions
Nom.
Cooling
Method
Nom.
EWAQ-ADVP
kW
kW
. ()
Unit
Weight
Height
Width
Depth
Unit
Operation weight
Water heat
Type
exchanger
Water flow rate Cooling Nom.
Air heat exchanger Type
Hydraulic components Expansion vessel Volume
Compressor
Type
Quantity
Fan
Type
Quantity
Sound power level Cooling
Nom.
Sound pressure level Cooling
Nom.
Operation range Water side
Cooling Min.~Max.
Air side
Cooling Min.~Max.
Refrigerant
Type
Charge
Control
Circuits
Quantity
Water circuit
Piping connections diameter
Piping connections Water heat exchanger drain
Unit
Maximum running current
Power supply
Phase/Frequency/Voltage
() Tamb °C - LWE °C (Dt: °C)


. ()
. ()
mm
mm
mm
kg
kg
l/min
l
dBA
dBA
°CDB
°CDB
kg
inch
A
Hz/V
.

. ()
. ()
Inverter controlled
. ()

,



Brazed plate
.
Tube type

Hermetically sealed swing compressor

Propeller fan



~
~
R-A
.
Inverter

“ MBSP
/ SAE flare
.
~//
Digital controller

. ()
. ()
. ()
.


EWAQ-ACV3/ACW1
Air cooled mini inverter chiller
 Inverter technology to ensure low sound values and leader-ofclass ESEER
 Wide operating range
 Built-in hydronic module: no buffer tank required and a standard
pump and main switch are included
 Easy ‘plug and play’ installation
 Single phase power supply for residential applications, three
phase power supply model available for light commercial
applications
EWAQ-ACV/ACW
Cooling only
Cooling capacity
Power input
Capacity control
EER
ESEER
Dimensions
Weight
Water heat
exchanger
Nom.
Cooling
Method
Unit
Nom.
Height
Width
Depth
Digital controller
EWAQ
ACV
ACV
kW . () / . () . () / . ()
kW . () / . () . () / . ()
mm
mm
mm
kg
Unit
Type
Quantity
Water volume
l
Water flow rate Cooling Nom.
l/min
Air heat exchanger Type
Hydraulic components Expansion vessel Volume
l
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Cooling Nom.
m³/min
Fan motor
Speed
Cooling Nom.
rpm
Steps
Sound power level Cooling
Nom.
dBA
Sound pressure
Cooling
Nom.
dBA
level
Cooling Night quiet mode
dBA
°CDB
Operation range Water side
Cooling Min.~Max.
°CDB
Air side
Cooling Min.~Max.
Refrigerant
Type
Charge
kg
Control
Circuits
Quantity
Water circuit
Piping connections diameter
inch
Piping
inch
Power supply
Phase/Frequency/Voltage
Hz/V
ACV
ACW
ACW
ACW
. () / . ()
. () / . ()
. () / . () . () / . ()
. () / . () . () / . () . () / . () . () / . ()
Inverter controlled
. () / . () . () / . () . () / . () . () / . () . () / . () . () / . ()
.
.
.
.
.
.
,
,


Brazed plate

.
.
.
.
.
.
.
Hi-XSS

Hermetically sealed scroll compressor

Propeller fan












~
~
R-A
.
Electronic expansion valve

G /“ (female)
/“
~//
N~//
() Underfloor program: cooling Ta °C - LWE °C (Dt: °C) () Fan coil program: cooling Ta °C - LWE °C ( Dt: °C)

EWAQ-BAWN/BAWP
Air cooled scroll inverter chiller





High efficiency with leader-of-class ESEER
Minimal starting currents and short payback times
No buffertank required for standard applications
Large operation range (ambient temperature up to °C)
A modbus gateway (RTD-W) can be installed per unit in order
allow the control and monitoring by a Daikin controller or a thirdparty BMS, which will increase further the efficiency of the system
 All systems that are connected with RTD-W can be controlled
and monitored centrally with the master/slave control kit: the
sequencing controller EKCC-W
EWAQ-BAWN/BAWP
Cooling only
Cooling capacity
Power input
Capacity control
BRCA
EWAQ-BAWN/BAWP






kW . () / . () . () / . () . () / . () . () / . () . () / . () . () / . ()
kW . () / . () . () / . () . () / . () . () / . () . () / . () . () / . ()
Inverter controlled
%

. () / . () . () / . () . () / . () . () / . () . () / . () . () / . ()
EER
ESEER
. () / . () . () / . () . () / . () . () / . () . () / . () . () / . ()
Dimensions
Unit
Height
mm
,
Width
mm
,
,
,
Depth
mm


Weight
Unit
kg




Operation weight
kg




Water heat
Type
Brazed plate
exchanger
Water volume
l
.
.
.
Water flow rate Cooling Nom.
l/min






Water pressure drop Cooling Total
kPa





Air heat exchanger Type
Hi-XSS
Compressor
Type
Hermetically sealed scroll compressor
Quantity




Fan
Type
Axial
Quantity


Air flow rate
Cooling Nom.
m³/min




Sound power level Cooling
Nom.
dBA



°CDB
~
Operation range Water side
Cooling Min.~Max.
°CDB
-~
Air side
Cooling Min.~Max.
Refrigerant
Type
R-A
Charge
kg
.
.
.
Control
Electronic expansion valve
Circuits
Quantity

Water circuit
Piping connections diameter
inch
-/“ (female)
“ (female)
Piping
inch
-/“
-/“
Unit
Maximum starting current
A

.
.
.
.
.
Maximum running current
A
.
.
.
.
.
.
Power supply
Phase/Frequency/Voltage
Hz/V
N~//
Nom.
Cooling
Nom.
Method
Minimum capacity
() EWAQ-BAWN: Naked version () EWAQ-BAWP: Verison with pump


. () / . ()
. () / . ()
. () / . ()
. () / . ()
,


.






.
.
.
EWAQ-E-XS/XL
Air cooled multi-scroll chiller,
high efficiency,
standard/low sound
 Reliable and efficient scroll compressors with high EER values
 A series of advantages thanks to the use of large-capacity scroll
compressors: increased competitiveness, reduced weight,
clearances around the unit
 Reduced footprint thanks to the V-shaped frame
 Large operation range: ambient temperatures up to °C and
down to -°C
 Ideal solution for a broad range of comfort and process
applications
 The unit can be equipped with a hydraulic module optimizing
installation time, space and cost
 MicroTech III controller with superior control logic and easy
interface
Cooling only
Cooling capacity
Power input
Capacity control
EER
ESEER
IPLV
Dimensions
Weight (XS)
Nom.
Cooling
Nom.
Method
Minimum capacity
EWAQ-E-XS/XL
kW
kW


.


.


.
%
.
.
.
.
.
Height
Width
Depth
Unit
Operation weight
Weight (XL)
Unit
Operation weight
Water heat
Type
exchanger
Water volume
Water flow rate Cooling Nom.
Water pressure drop Cooling Nom.
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Nom.
Speed
Sound power level (XS) Cooling
Nom.
Sound power level (XL) Cooling
Nom.
Sound pressure level (XS) Cooling
Nom.
Sound pressure level (XL) Cooling
Nom.
Operation range Water side
Cooling Min.~Max.
Air side
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage







.
.
.
.
.
.
.
.
.
.
.
Step
.
.
Unit


.
mm
mm
mm
kg
kg
kg
kg
,
,
,
,
,
l
l/s
kPa
.

,
,
,
,


l/s
rpm
dBA
dBA
dBA
dBA
°CDB
°CDB
,



kg

A
A
A
Hz/V



,
,
,
,
.
.
,
,
,
,
,
,
,
,
Plate heat exchanger
,
,
,
,
,

.
.
.
.



High efficiency fin and tube type with integral subcooler
Scroll compressor


Direct propeller

,
,
,
,











-~
-~
R-A





“












~//
,
,
,
,
.


,








EWAQ-E-XR
Air cooled multi-scroll chiller,
high efficiency,
reduced sound
EWAQ-E-XS/XL/XR
Cooling only
Cooling capacity
Power input
Capacity control
EER
ESEER
IPLV
Dimensions
Weight
Nom.
Cooling
Nom.
Method
Minimum capacity
Unit
EWAQ-E-XR
kW
kW


.


.


.
%
.
.
.
.
.
.
.
.
.
.
.
.
Height
Width
Depth
Unit
Operation weight
Water heat
Type
exchanger
Water volume
Water flow rate Cooling Nom.
Water pressure drop Cooling Nom.
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Nom.
Speed
Sound power level Cooling
Nom.
Sound pressure level Cooling
Nom.
Operation range Water side
Cooling Min.~Max.
Air side
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage
MicroTech III


.






.
.
.
.
.
.
.
.
.
.
.
.
,
,
,
,
Plate heat exchanger
,
,
Step
mm
mm
mm
kg
kg
,
,
l
l/s
kPa
.

,
,
,


l/s
rpm
dBA
dBA
°CDB
°CDB
,
,
,
,



kg

A
A
A
Hz/V



,

.
.
.
.




High efficiency fin and tube type with integral subcooler
Scroll compressor


Direct propeller

,
,
,
,










-~
-~
R-A





“












~//
,
,
.


,







291
EWAQ-F-SS/SL
Air cooled multi-scroll chiller,
standard efficiency,
standard/low sound
 Reliable and efficient scroll compressors with high EER values
 A series of advantages thanks to the use of large-capacity scroll
compressors: increased competitiveness, reduced weight,
clearances around the unit
  truly independent refrigerant circuits
 Reduced footprint thanks to the V-shaped frame
(EWAQ-/F-SS/SL & EWAQ-/F-SR)
 Large operation range: ambient temperatures up to °C and
down to -°C
 The unit can be equipped with a hydraulic module optimizing
installation time, space and cost
 Ideal solution for a broad range of comfort and process
applications
 MicroTech III controller with superior control logic and easy
interface
Cooling only
Cooling capacity
Power input
Capacity control
EER
ESEER
IPLV
Dimensions
Weight (SS)
Nom.
Cooling
Nom.
Method
Minimum capacity
Unit
EWAQ-F-SS/SL
kW
kW


.


.
%
.
.
.
.
.
Height
Width
Depth
Unit
Operation weight
Weight (SL)
Unit
Operation weight
Water heat
Type
exchanger
Water volume
Water flow rate Cooling Nom.
Water pressure drop Cooling Nom.
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Nom.
Speed
Sound power level (SS) Cooling
Nom.
Sound power level (SL) Cooling
Nom.
Sound pressure level (SS) Cooling
Nom.
Sound pressure level (SL) Cooling
Nom.
Operation range Water side
Cooling Min.~Max.
Air side
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage

mm
mm
mm
kg
kg
kg
kg
l
l/s
kPa
.
.
,
,
,
,
,

.

.

,




kg
A
A
A
Hz/V
.

















Step
.
.














.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
, , , , ,
, , , ,
,
,
, ,
, , , , , ,
, , , , , , ,
,
,
,
, , ,
,
,
,
,
,
,
,
Plate heat exchanger



.
.
.
.
.
.
.
.
.









High efficiency fin and tube type with integral subcooler
Scroll compressor


Direct propeller




, , ,
,
, , , , ,





















-~
-~
R-A









“

























~//
.

l/s
rpm
dBA
dBA
dBA
dBA
°CDB
°CDB


.
EWAQ-F-SR
Air cooled multi-scroll chiller,
standard efficiency,
reduced sound
EWAQ-F-SS/SL/SR
Cooling only
Cooling capacity
Power input
Capacity control
EER
ESEER
IPLV
Dimensions
Weight
Nom.
Cooling
Nom.
Method
Minimum capacity
Unit
EWAQ-F-SR
kW
kW


.


.


.






%
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
,
,
.
.
.
.
Height
Width
Depth
Unit
Operation weight
Water heat
Type
exchanger
Water volume
Water flow rate Cooling Nom.
Water pressure drop Cooling Nom.
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Nom.
Speed
Sound power level Cooling
Nom.
Sound pressure level Cooling
Nom.
Operation range Water side
Cooling Min.~Max.
Air side
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage
mm
mm
mm
kg
kg
l
l/s
kPa
,
,
,

.

.


l/s
rpm
dBA
dBA
°CDB
°CDB
,


kg
A
A
A
Hz/V













Step
.
.
.
.
MicroTech III




.
.









.
.
.
.
.
.
.
.
.
.
.
.
,
,
,
,
,
,
,
,
,
,
.
.
.
.
.
.
,
,
,
,
,
,
,
,
,
,
,
,
,
, ,
,
,
, , ,
,
,
,
,
Plate heat exchanger


.
.
.
.
.
.






High efficiency fin and tube type with integral subcooler
Scroll compressor

Direct propeller



, , ,
,
,
,










-~
-~
R-A







“


















~//

.

.



,
,












293
EWAQ-F-XS/XL
Air cooled multi-scroll chiller,
high efficiency,
standard/low sound
 Reliable and efficient scroll compressors with high EER values
 A series of advantages thanks to the use of large-capacity scroll
compressors: increased competitiveness, reduced weight,
clearances around the unit
  truly independent refrigerant circuits
 Reduced footprint thanks to the V-shaped frame
(EWAQ-/F-XS/XL & EWAQ-/F-XR)
 Large operation range: ambient temperatures up to °C and
down to -°C
 The unit can be equipped with a hydraulic module optimizing
installation time, space and cost
 Ideal solution for a broad range of comfort and process
applications
 MicroTech III controller with superior control logic and easy
interface
Cooling only
Cooling capacity
Power input
Capacity control
EER
ESEER
IPLV
Dimensions
Weight (XS)
Nom.
Cooling
Nom.
Method
Minimum capacity
Unit
EWAQ-F-XS/XL
kW
kW


.


.


.
%
.
.
.
.
.
.
.
.
.
Height
Width
Depth
Unit
Operation weight
Weight (XL)
Unit
Operation weight
Water heat
Type
exchanger
Water volume
Water flow rate Cooling Nom.
Water pressure drop Cooling Nom.
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Nom.
Speed
Sound power level (XS) Cooling
Nom.
Sound power level (XL) Cooling
Nom.
Sound pressure level (XS) Cooling
Nom.
Sound pressure level (XL) Cooling
Nom.
Operation range Water side
Cooling Min.~Max.
Air side
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage

mm
mm
mm
kg
kg
kg
kg
l
l/s
kPa
l/s
rpm
dBA
dBA
dBA
dBA
°CDB
°CDB
kg
A
A
A
Hz/V


.








Step
.


















.
.
.
. .
.
.
.
.
.
.
.
.
.
. . . . . . . . . . . .
. . . . . . . .
.
. . .
,
, ,
,
,
, ,
,
,
,
, , , ,
,
,
,
, , , , , , , , , , , , , ,
, , , ,
,
, , , , , , , ,
, , , , , , , , , , , , , ,
, , , , , , , , , , , , , ,
Plate heat exchanger





.
.
.
.
.
.
.
.
.
. . .












High efficiency fin and tube type with integral subcooler
Scroll compressor


Direct propeller






, , , ,
,
,
,
,
,
,

































-~
-~
R-A










“




































~//
EWAQ-F-XR
Air cooled multi-scroll chiller,
high efficiency,
reduced sound
EWAQ-F-XS/XL/XR
Cooling only
Cooling capacity
Power input
Capacity control
EER
ESEER
IPLV
Dimensions
Weight
Nom.
Cooling
Nom.
Method
Minimum capacity
Unit
EWAQ-F-XR
kW
kW


.


.
%
.
.
.
.
.
.
.
.
Height
Width
Depth
Unit
Operation weight
Water heat
Type
exchanger
Water volume
Water flow rate Cooling Nom.
Water pressure drop Cooling Nom.
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Nom.
Speed
Sound power level Cooling
Nom.
Sound pressure level Cooling
Nom.
Operation range Water side
Cooling Min.~Max.
Air side
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage
mm
mm
mm
,
kg , ,
kg , ,
l
l/s
kPa

.

.


l/s , ,
rpm
dBA 

dBA 

°CDB
°CDB
kg


A
A
A
Hz/V








.


.




MicroTech III

 

   














Step
. .
.
.
.
. .
.
.
.
. .
.
.
.
.
.
. .
. . . . . . . . . . . .
.
. .
.
. . . . .
.
.
.
,
, ,
,
,
, ,
,
,
, , , ,
,
,
,
, , , , , , , , , , , ,
, , , , , , , , , , , ,
Plate heat exchanger




.
.
.
.
.
.
. .
.
.









High efficiency fin and tube type with integral subcooler
Scroll compressor


Direct propeller





, ,
,
,
,
,
,
,



















-~
-~
R-A









“






























~//
295
EWAQ-GZXS
Air cooled multi-scroll
inverter chiller,
high efficiency,
standard sound
 High efficiency DC inverter scroll compressors
 Advanced compressor and fan design resulting in low operating
sound levels
 Dual independent refrigerant circuit for built-in redundancy and
reliable operation
 Wide operating range in cooling mode
 Reduced footprint thanks to the V-shaped frame (EWAQGZXS
& EWAQGZXR)
 MicroTech III controller with superior control logic and easy
interface
Cooling only
Cooling capacity
Power input
Capacity control
EER
ESEER
IPLV
Dimensions
Weight
Nom.
Cooling
Nom.
Method
Minimum capacity
Unit
EWAQ-GZXS
kW
kW
Height
Width
Depth
Unit
Operation weight
Water heat
Type
exchanger
Water volume
Water flow rate Cooling Nom.
Water pressure drop Cooling Total
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Nom.
Speed
Sound power level Cooling
Nom.
Sound pressure level Cooling
Nom.
Operation range Water side
Cooling Min.~Max.
Air side
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage



.


.
.
.
.
.
mm
mm
mm
kg
kg
.
.
.
.
,
,
,
,
,
l
l/s
kPa

.

%

l/s
rpm
dBA
dBA
°CDB
°CDB
kg
A
A
A
Hz/V

,




.“





Stepless
.
.
.
.






.
.
.
.
.
.
.
.
,
,
,
,
,
,
,
,
Plate heat exchanger



.
.
.



High efficiency fin and tube type with integral subcooler
DC Inverter Scroll


Direct propeller


,
,




-~
-~
R-A



.“







~//
,
,
,
,

.





EWAQ-GZXR
Air cooled multi-scroll
inverter chiller,
high efficiency,
reduced sound
EWAQ-GZXS/XR
Cooling only
Cooling capacity
Power input
Capacity control
EER
ESEER
IPLV
Dimensions
Weight
Nom.
Cooling
Nom.
Method
Minimum capacity
Unit
EWAQ-GZXR
kW
kW
Height
Width
Depth
Unit
Operation weight
Water heat
Type
exchanger
Water volume
Water flow rate Cooling Nom.
Water pressure drop Cooling Total
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Nom.
Speed
Sound power level Cooling
Nom.
Sound pressure level Cooling
Nom.
Operation range Water side
Cooling Min.~Max.
Air side
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage


.


.
.
.
.
mm
mm
mm
kg
kg
.
.
.
.
,
,
,
,
,
l
l/s
kPa

.

%

l/s
rpm
dBA
dBA
°CDB
°CDB
kg
A
A
A
Hz/V

,




.“


MicroTech III



Stepless
.
.
.






.
.
.
.
.
.
.
.
,
,
,
,
,
,
,
,
,
,
,
Plate heat exchanger



.
.
.


High efficiency fin and tube type with integral subcooler
DC Inverter Scroll


Direct propeller


,
,





-~
-~
R-A



.“







~//
,
,

.




297
EWAD-E-SS
Air cooled screw chiller,
standard efficiency,
standard sound




One refrigerant circuit with single screw compressor
Compact design with brazed plate heat exchanger
Large operation range (ambient temperature down to -°C)
Water supply down to -°C
Cooling only
Cooling capacity
Power input
Capacity control
EER
ESEER
IPLV
Dimensions
Weight
Nom.
Cooling
Nom.
Method
Minimum capacity
Unit
EWAD-E-SS
kW
kW
Height
Width
Depth
Unit
Operation weight
Water heat
Type
exchanger
Water volume
Water flow rate Cooling Nom.
Water pressure drop Cooling Nom.
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Nom.
Speed
Sound power level Cooling
Nom.
Sound pressure level Cooling
Nom.
Operation range Water side
Cooling Min.~Max.
Air side
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage



.


.


.


.
.
.
.
.
.
.
.
.
.
.
.
.
%
mm
mm
mm
kg
kg
l
l/s
kPa
l/s
rpm
dBA
dBA
°CDB
°CDB
kg
A
A
A
Hz/V
,
,
,
,
,
,
,
,




.
.
Stepless
.
.
.
.
.
.
.


.









.
.
.
.
.
.
.
.
.
.
.
.
,
,
,
,
,
,
,
,
Plate heat exchanger










.
.
.
.
.
.
.
.
.
.









High efficiency fin and tube type with integral subcooler
Single screw compressor
Asymmetric single screw compressor

Direct propeller




,
,
,
,
,
,
,
,








-~
-~
R-a










“

























~//
EWAD-E-SL
Air cooled screw chiller,
standard efficiency,
low sound
EWAD-E-SS/SL
Cooling only
Cooling capacity
Power input
Capacity control
EER
ESEER
IPLV
Dimensions
Weight
Nom.
Cooling
Nom.
Method
Minimum capacity
Unit
EWAD-E-SL
kW
kW
Height
Width
Depth
Unit
Operation weight
Water heat
Type
exchanger
Water volume
Water flow rate Cooling Nom.
Water pressure drop Cooling Nom.
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Nom.
Speed
Sound power level Cooling
Nom.
Sound pressure level Cooling
Nom.
Operation range Water side
Cooling Min.~Max.
Air side
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage

.
.


.


.


.
.
.
.
.
.
.
.
.
.
.
.
.
%
mm
mm
mm
kg
kg
l
l/s
kPa
,
,
,

.


l/s
rpm
dBA
dBA
°CDB
°CDB
,

kg

A
A
A
Hz/V



,
,
,
,
,




.
.
Stepless
.
.
.
.
.
.
.
MicroTech III


.









.
.
.
.
.
.
.
.
.
.
.
.
,
,
,
,
,
,
,
,
Plate heat exchanger









.
.
.
.
.
.
.
.
.







High efficiency fin and tube type with integral subcooler
Single screw compressor
Asymmetric single screw compressor

Direct propeller



,
,
,
,
,
,
,







-~
-~
R-a









“






















~//
299
EWAD-D-SS
Air cooled screw chiller,
standard efficiency,
standard sound





 truly independent refrigerant circuits
Stepless single-screw compressor
Optimised for use with R-a
Large operation range (ambient temperature down to -°C)
MicroTech III controller with superior control logic and easy
interface
Cooling only
Cooling capacity
Power input
Capacity control
EER
ESEER
IPLV
Dimensions
Weight
Nom.
Cooling
Nom.
Method
Minimum capacity
Unit
EWAD-D-SS
kW
kW
Height
Width
Depth
Unit
Operation weight
Water heat
Type
exchanger
Water volume
Water flow rate Cooling Nom.
Water pressure drop Cooling Nom.
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Nom.
Speed
Sound power level Cooling
Nom.
Sound pressure level Cooling
Nom.
Operation range Water side
Cooling Min.~Max.
Air side
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage










.
.
.
.
.
.
.
.
.
%
mm
mm
mm
kg
kg
,
,
,
l
l/s
kPa

.




.
.
.






.
.
.
.
.
.
,
,
,
,
,
Single screw compressor

l/s
rpm
dBA
dBA
°CDB
°CDB



Stepless
.
,

kg

A
A
A
Hz/V



,
,
,
Single pass shell & tube



.
.
.
.
.





High efficiency fin and tube type with integral subcooler
Asymmetric single screw compressor

Direct propeller

,
,





-~
-~
R-a






.“












~//
,

.

,




EWAD-D-SL
Air cooled screw chiller,
standard efficiency,
low sound
EWAD-D-SS/SL
Cooling only
Cooling capacity
Power input
Capacity control
EER
ESEER
IPLV
Dimensions
Weight
Nom.
Cooling
Nom.
Method
Minimum capacity
Unit
EWAD-D-SL
kW
kW
Height
Width
Depth
Unit
Operation weight
Water heat
Type
exchanger
Water volume
Water flow rate Cooling Nom.
Water pressure drop Cooling Nom.
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Nom.
Speed
Sound power level Cooling
Nom.
Sound pressure level Cooling
Nom.
Operation range Water side
Cooling Min.~Max.
Air side
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage


.


.


.


.






.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
,
.
.
.
%
mm
mm
mm
,
kg , ,
kg
,
Plate heat exchanger
l 

l/s .
.
kPa 


l/s , ,
rpm
dBA
dBA
°CDB
°CDB
kg
A
A
A
Hz/V


“










Stepless
.
. .
.
.
. .
MicroTech III


















.
.
.
.
.
.
.
.
.
.
.
.
,
.
.
.
.
.
.
,
,
,
,
,
,
, ,
,
,
,
,
,
Single pass shell & tube






.
.
.
.
.
.
.
.
.
.
.
.












High efficiency fin and tube type with integral subcooler
Asymmetric single screw compressor
Single screw compressor

Direct propeller




,
,
,
,
,
,
,












-~
-~
R-a










“
“
































~//
301
EWAD-D-SR
Air cooled screw chiller,
standard efficiency,
reduced sound





 truly independent refrigerant circuits
Stepless single-screw compressor
Optimised for use with R-a
Large operation range (ambient temperature down to -°C)
MicroTech III controller with superior control logic and easy
interface
Cooling only
Cooling capacity
Power input
Capacity control
EER
ESEER
IPLV
Dimensions
Weight
Nom.
Cooling
Nom.
Method
Minimum capacity
Unit
EWAD-D-SR
kW
kW
Height
Width
Depth
Unit
Operation weight
Water heat
Type
exchanger
Water volume
Water flow rate Cooling Nom.
Water pressure drop Cooling Nom.
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Nom.
Speed
Sound power level Cooling
Nom.
Sound pressure level Cooling
Nom.
Operation range Water side
Cooling Min.~Max.
Air side
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage



.


.


.


.






.
.
.
.
.
.
.
.
.
.
.
.
.
.
,
.
.
.
%
mm
mm
mm
kg
kg

l/s , ,
rpm
dBA
dBA
°CDB
°CDB
A
A
A
Hz/V


















.
.
.
.
.
.
.
.
.
.
.
.
,
.
.
.
.
.
.
,
,
,
,
Plate heat exchanger
l 

l/s .
.
kPa 

kg






Stepless
.
. .
.
.
.
.


“




,
,
,
,
,
,
,
,
,
,
Single pass shell & tube






.
.
.
.
.
.
.
.
.
.
.
.











High efficiency fin and tube type with integral subcooler
Asymmetric single screw compressor
Single screw compressor

Direct propeller




,
,
,
,
,
,
,












-~
-~
R-a










“
“
































~//
EWAD-D-SX
Air cooled screw chiller,
standard efficiency,
extra low sound
EWAD-D-SX/SR
Cooling only
Cooling capacity
Power input
Capacity control
EER
ESEER
IPLV
Dimensions
Weight
Nom.
Cooling
Nom.
Method
Minimum capacity
Unit
EWAD-D-SX
kW
kW
Height
Width
Depth
Unit
Operation weight
Water heat
Type
exchanger
Water volume
Water flow rate Cooling Nom.
Water pressure drop Cooling Nom.
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Nom.
Speed
Sound power level Cooling
Nom.
Sound pressure level Cooling
Nom.
Operation range Water side
Cooling Min.~Max.
Air side
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage


.


.


.



.
.
.
.
.
.
.
.
.
.
.
.
%
mm
mm
mm
kg
kg
,
,
,
l
l/s
kPa

.

l/s
rpm
dBA
dBA
°CDB
°CDB

,

kg

A
A
A
Hz/V









Stepless
.
.
.
.
.
.
.
,
,
,
,
MicroTech III















.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
,
,
,
,
,
,
,
,
,
,
,
Single pass shell & tube






.
.
.
.
.
.
.
.
.
.









High efficiency fin and tube type with integral subcooler
Asymmetric single screw compressor
Single screw compressor

Direct propeller



,
,
,
, ,





-~
-~
R-a









“
“



























~//
,
303
EWAD-D-XS
Air cooled screw chiller,
high efficiency,
standard sound





 truly independent refrigerant circuits
Stepless single-screw compressor
Optimised for use with R-a
Large operation range (ambient temperature down to -°C)
MicroTech III controller with superior control logic and easy
interface
Cooling only
Cooling capacity
Power input
Capacity control
EER
ESEER
IPLV
Dimensions
Weight
Nom.
Cooling
Nom.
Method
Minimum capacity
Unit
EWAD-D-XS
kW
kW
Height
Width
Depth
Unit
Operation weight
Water heat
Type
exchanger
Water volume
Water flow rate Cooling Nom.
Water pressure drop Cooling Nom.
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Nom.
Speed
Sound power level Cooling
Nom.
Sound pressure level Cooling
Nom.
Operation range Water side
Cooling Min.~Max.
Air side
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage



.


.


.






.
.
.
.
.
.
.
.
.
.
,
.
.
.
%
mm
mm
mm
kg
kg
,
,
,
l
l/s
kPa

.

l/s
rpm
dBA
dBA
°CDB
°CDB
.



Stepless
.
.
.
.















.
.
.
.
.
.
.
.
.
.
.
.
.
.
,
,

,
kg

A
A
A
Hz/V



,
,
,
,
,
,
,
,
,
,
Single pass shell & tube





.
.
.
.
.
.
.
.
.
.










High efficiency fin and tube type with integral subcooler
Asymmetric single screw compressor
Single screw compressor

Direct propeller


,
,
, , ,
,






-~
-~
R-a









“
”



























~//
,
EWAD-D-XR
Air cooled screw chiller,
high efficiency,
reduced sound
EWAD-D-XS/XR
Cooling only
Cooling capacity
Power input
Capacity control
EER
ESEER
IPLV
Dimensions
Weight
Nom.
Cooling
Nom.
Method
Minimum capacity
Unit
EWAD-D-XR
kW
kW
Height
Width
Depth
Unit
Operation weight
Water heat
Type
exchanger
Water volume
Water flow rate Cooling Nom.
Water pressure drop Cooling Nom.
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Nom.
Speed
Sound power level Cooling
Nom.
Sound pressure level Cooling
Nom.
Operation range Water side
Cooling Min.~Max.
Air side
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage


.


.


.






.
.
.
.
.
.
.
.
.
.
.
.
,
.
.
.
%
mm
mm
mm
kg
kg
,
,
,
l
l/s
kPa

.

l/s
rpm
dBA
dBA
°CDB
°CDB



Stepless
.
.
.
.
MicroTech III









.
.
.
.
.
.
.






.
.
.
.
.
.
.
,
,

,
kg

A
A
A
Hz/V



,
,
,
,
,
,
,
,
,
,
Single pass shell & tube





.
.
.
.
.
.
.
.
.
.









High efficiency fin and tube type with integral subcooler
Asymmetric single screw compressor
Single screw compressor

Direct propeller


,
,
, , ,
,







-~
-~
R-a










“
”



























~//
,
305
EWAD-D-HS
Air cooled screw chiller,
high ambient,
standard sound





High ambient
Stepless single-screw compressor
Optimised for use with R-a
Large operation range (ambient temperature down to -°C)
MicroTech III controller with superior control logic and easy
interface
EWAD-D-HS
Cooling only
Cooling capacity
Power input
Capacity control
EER
ESEER
IPLV
Dimensions
Weight
Nom.
Cooling
Nom.
Method
Minimum capacity
EWAD-D-HS 
kW 
kW .
Height
Width
Depth
Unit
Operation weight
Water heat
Type
exchanger
Water volume
Water flow rate Cooling Nom.
Water pressure drop Cooling Nom.
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Nom.
Speed
Cooling Nom.
Sound power level Cooling
Nom.
Sound pressure level Cooling
Nom.
Operation range Water side
Cooling Min.~Max.
Air side
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage



.


.


.



.
.
.
.
. .
. .
.
.
.
.
.
.
%
.
.
.
Unit


.
mm
mm
mm
,
kg , ,
kg
,
Plate heat exchanger
l 

l/s .
.
kPa 


l/s , ,
rpm
dBA
dBA
°CDB
°CDB
kg
A
A
A
Hz/V


“




,






Stepless
.
. .
.
.
. .
,
,
MicroTech III





















.
.
.
.
.
.
. .
.
. .
.
.
.
.
.
.
.
.
.
,
,
,
, , ,
,
,
,
,
, ,
,
Single pass shell & tube






.
.
.
. . . . . . . . . .













High efficiency fin and tube type with integral subcooler
Asymmetric single screw compressor
Single screw compressor

Direct propeller



,
,
,
,
,
,














-~
-~
R-a












“
“



 

 









 

  


  

      
~//
,
,
EWAD-C-SS/SL
Air cooled screw chiller,
standard efficiency,
standard/low sound
 Stepless single-screw compressor
 Optimised for use with R-a
 Large operation range (ambient temperature down to -°C and
up to °C)
 All models are PED pressure vessel approved
 - truly independent refrigerant circuits
 Standard electronic expansion valve
 DX shell and tube evaporator – one pass refrigerant side to
minimize pressure drops
 Partial and total heat recovery option available
 MicroTech III controller with superior control logic and easy
interface
Cooling only
Cooling capacity
Power input
Capacity control
EER
ESEER
IPLV
Dimensions
Weight (SS)
Nom.
Cooling
Nom.
Method
Minimum capacity
EWAD-C-SS/SL 
kW 
kW 
Unit
Height
Width
Depth
mm
mm
mm
kg
kg
kg
kg
l
l/s
kPa
l/s
rpm
dBA
dBA
dBA
dBA
°CDB
°CDB
kg
A
A
A
Hz/V









C C
, ,
 
.
.
.
.
.
.
.
C H
, ,
 
Stepless
C
,

C C C C
, , , ,
   
C
,

.
.
.
. . . .
. . . . . .
.
.
. . . . . .
,
,
,
, ,
,
,
,
,
, , , , , , ,
,
, , , ,
,
, , , , , , ,
,
, , , ,
,
, , , , , , ,
,
, , , ,
,
, , , , , , ,
,
, , , ,
,
Single pass shell & tube







. . . . . . . . . . . . . . .















High efficiency fin and tube type with integral subcooler
Asymmetric single screw compressor


Direct propeller








,
,
,
,
,
,
, ,





















-~
-~
R-a





  





.mm
.mm
mm


  , , , , , , , , , ,
   
   
  . , , , ,
   

 

 , , , , , ,
~//
.
.
.
Unit
Operation weight
Weight (SL)
Unit
Operation weight
Water heat
Type
exchanger
Water volume
Water flow rate Cooling Nom.
Water pressure drop Cooling Nom.
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Nom.
Speed
Sound power level (SS) Cooling
Nom.
Sound power level (SL) Cooling
Nom.
Sound pressure level (SS) Cooling
Nom.
Sound pressure level (SL) Cooling
Nom.
Operation range Water side
Cooling Min.~Max.
Air side
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage

%



.
.
.
.
.
.
.
.
.
.
.
.
EWAD-C-SR
Air cooled screw chiller,
standard efficiency,
reduced sound
EWAD-C-SS/SL/SR
Cooling only
Cooling capacity
Power input
Capacity control
EER
ESEER
IPLV
Dimensions
Weight
Nom.
Cooling
Nom.
Method
Minimum capacity
Unit
EWAD-C-SR 
kW 
kW 
Height
Width
Depth
Unit
Operation weight
Water heat
Type
exchanger
Water volume
Water flow rate Cooling Nom.
Water pressure drop Cooling Nom.
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Nom.
Speed
Sound power level Cooling
Nom.
Sound pressure level Cooling
Nom.
Operation range Water side
Cooling Min.~Max.
Air side
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage
%
mm
mm
mm
kg
kg
l
l/s
kPa
l/s
rpm
dBA
dBA
°CDB
°CDB
kg
A
A
A
Hz/V









MicroTech III
 C C C H C C C C
 , , , , , , , ,
        
Stepless
.
.
. . . . . . . . . . . . .
. . . . . . . . . . . . .
. . . .
.
. . . . . . .
,
,
,
, ,
,
,
,
, , , ,
, , , , , , ,
,
, , , , , , ,
,
,
, ,
Single pass shell & tube







. . . . . . . . . . . . .













High efficiency fin and tube type with integral subcooler
Asymmetric single screw compressor


Direct propeller







,
,
, ,
,
,
,








-~
-~
R-a

   




.mm
.mm


  , , , , , , , ,
           , ,
         , , , ,
~//
C C C
, , ,
  
.
.
.
,
,
.

.
.
.
.
.
.
,
,
,

.

.


,




mm
, , ,
, , ,
, , ,
309
EWAD-C-XS/XL
Air cooled screw chiller,
high efficiency,
standard/low sound
 Stepless single-screw compressor
 Optimised for use with R-a
 Large operation range (ambient temperature down to -°C and
up to °C)
 All models are PED pressure vessel approved
 - truly independent refrigerant circuits
 Standard electronic expansion valve
 DX shell and tube evaporator – one pass refrigerant side to
minimize pressure drops
 Partial and total heat recovery option available
 MicroTech III controller with superior control logic and easy
interface
Cooling only
Cooling capacity
Power input
Capacity control
EWAD-C-XS/XL     C C C C H H C C C C C C C
kW     , , , , , , , , , , , , ,
kW                 
Stepless
%
.
.
EER
. . . . . . . . . . . .
.
. . .
ESEER
. . . . . . . . . . . . . . . . .
IPLV
.
. . . . . . . . . . . . . . .
Dimensions
Unit
Height
mm
,
Width
mm
,
, , ,
,
Depth
mm ,
,
,
,
, , ,
,
Weight (XS)
Unit
kg , , , , , , ,
,
,
, , ,
,
Operation weight
kg , , , , , , ,
, , ,
,
Weight (XL)
Unit
kg , , , , , , ,
,
,
, , ,
,
Operation weight
kg , , , , , , ,
Water heat
Type
Single pass shell & tube
exchanger
Water volume
l 







Water flow rate Cooling Nom.
l/s . . . . . . . . . . . . . . . . .
Water pressure drop Cooling Nom.
kPa 















Air heat exchanger Type
High efficiency fin and tube type with integral subcooler
Compressor
Type
Asymmetric single screw compressor
Quantity


Fan
Type
Direct propeller
Quantity








,
,
,
, , ,
,
Air flow rate
Nom.
l/s ,
Speed
rpm

Sound power level (XS) Cooling
Nom.
dBA 




Sound power level (XL) Cooling
Nom.
dBA




Sound pressure level (XS) Cooling
Nom.
dBA




Sound pressure level (XL) Cooling
Nom.
dBA 


°CDB
-~
Operation range Water side
Cooling Min.~Max.
°CDB
-~
Air side
Cooling Min.~Max.
Refrigerant
Type
R-a
Charge
kg 

           

Circuits
Quantity


Piping connections Evaporator water inlet/outlet (OD)
.mm
.mm
mm
Unit
Maximum starting current
A 

 
,
, , , ,
,
, , ,
Nominal running current (RLA) Cooling
A             .  , , ,
Maximum running current
A      

  , , , , , , ,
Power supply
Phase/Frequency/Voltage
Hz/V
~//

Nom.
Cooling
Nom.
Method
Minimum capacity
EWAD-C-XR
Air cooled screw chiller,
high efficiency,
reduced sound
EWAD-C-XS/XL/XR
Cooling only
Cooling capacity
Power input
Capacity control
EER
ESEER
IPLV
Dimensions
Weight
Nom.
Cooling
Nom.
Method
Minimum capacity
Unit
EWAD-C-XR 
kW 
kW 
Height
Width
Depth
Unit
Operation weight
Water heat
Type
exchanger
Water volume
Water flow rate Cooling Nom.
Water pressure drop Cooling Nom.
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Nom.
Speed
Sound power level Cooling
Nom.
Sound pressure level Cooling
Nom.
Operation range Water side
Cooling Min.~Max.
Air side
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage
%
mm
mm
mm
kg
kg
l
l/s
kPa
l/s
rpm
dBA
dBA
°CDB
°CDB
kg
A
A
A
Hz/V
MicroTech III
   C C C C H H C C C C
   , , , , , , , , , ,
            
Stepless
.
.
. . . . . . . . . .
.
.
. . . . . . .
.
. . . . .
. . . . . . . . . . .
.
.
,
,
, , ,
,
,
,
,
, , ,
, , , , , , ,
,
,
, , ,
, , , , , , ,
Single pass shell & tube







. . . . . . . . . . . . . .













High efficiency fin and tube type with integral subcooler
Asymmetric single screw compressor


Direct propeller







,
,
,
,
, , ,









-~
-~
R-a


   

   


.mm
.mm
mm


 
,
, , , ,
,
             ,
     

  , , , ,
~//
C C C
, , ,
  
. . .
. . .
. . .
,
,
,

. . .




,




, , ,
, , ,
, , ,
311
EWAD-C-PS/PL
Air cooled screw chiller,
premium efficiency,
standard/low sound










Excellent part load efficiency
Stepless single-screw compressor
Optimised for use with R-a
Large operation range (ambient temperature down to -°C and
up to °C)
All models are PED pressure vessel approved
 truly independent refrigerant circuits
Standard electronic expansion valve
DX shell and tube evaporator – one pass refrigerant side to
minimize pressure drops
Partial and total heat recovery option available
MicroTech III controller with superior control logic and easy
interface
Cooling only
Cooling capacity
Power input
Capacity control
EER
ESEER
IPLV
Dimensions
Weight (PS)
Nom.
Cooling
Nom.
Method
Minimum capacity
Unit
EWAD-C-PS/PL
kW
kW
Height
Width
Depth
Unit
Operation weight
Weight (PL)
Unit
Operation weight
Water heat
Type
exchanger
Water volume
Water flow rate Cooling Nom.
Water pressure drop Cooling Nom.
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Nom.
Speed
Sound power level (PS) Cooling
Nom.
Sound power level (PL) Cooling
Nom.
Sound pressure level (PS) Cooling
Nom.
Sound pressure level (PL) Cooling
Nom.
Operation range Water side
Cooling Min.~Max.
Air side
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage







.
.
.
.
.
.
%
mm
mm
mm
kg
kg
kg
kg
l
l/s
kPa
l/s
rpm
dBA
dBA
dBA
dBA
°CDB
°CDB
kg
A
A
A
Hz/V
,
,
,
,
,

.

.


,



.mm








C
,

C
C
C
C
C
,
,
,
,
,





Stepless
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
Single pass shell & tube
,
,


.
.
.
.
.
.
.







High efficiency fin and tube type with integral subcooler
Asymmetric single screw compressor

Direct propeller



,
,
,














-~
-~
R-a





mm



,
,
,














~//
EWAD-C-PR
Air cooled screw chiller,
premium efficiency,
reduced sound
EWAD-C-PS/PL/PR
Cooling only
Cooling capacity
Power input
Capacity control
EER
ESEER
IPLV
Dimensions
Weight
Nom.
Cooling
Nom.
Method
Minimum capacity
Unit
EWAD-C-PR
kW
kW
Height
Width
Depth
Unit
Operation weight
Water heat
Type
exchanger
Water volume
Water flow rate Cooling Nom.
Water pressure drop Cooling Nom.
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Nom.
Speed
Sound power level Cooling
Nom.
Sound pressure level Cooling
Nom.
Operation range Water side
Cooling Min.~Max.
Air side
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage






.
.
.
.
.
%
mm
mm
mm
kg
kg
l
l/s
kPa
l/s
rpm
dBA
dBA
°CDB
°CDB
kg
A
A
A
Hz/V
,
,
,

.

.


,


.mm








C
,

MicroTech III
C
C
C
,
,
,



Stepless
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
,
,
,
,
,
,
,
,
,
,
,
,
Single pass shell & tube
,
,

.
.
.
.
.





High efficiency fin and tube type with integral subcooler
Asymmetric single screw compressor

Direct propeller


,
,




-~
-~
R-a




mm



,










~//
C
,

C
,

.
.
.
.
.
,
,
,

.

.


,



,


,


313
EWAD-CZXS/XL
Air cooled screw inverter chiller,
high efficiency,
standard/low sound
 High efficiency with leader-of-class ESEER
 Inverter stepless single-screw compressor
 Highly efficient fans with patented blade profile for quiet
operation
 Extensive option list (heat recovery option available)
 Wide operating range
 Low starting current
 Optimised for use with R-a
 MicroTech III controller with superior control logic and easy
interface
Cooling only
Cooling capacity
Power input
Capacity control
EER
ESEER
IPLV
Dimensions
Weight (XS)
Nom.
Cooling
Nom.
Method
Minimum capacity
EWAD-CZXS/XL
kW
kW



%
.
.
Unit
Height
Width
Depth
mm
mm
mm
kg
kg
kg
kg
,
,
,
,
,
l
l/s
kPa

.


l/s ,
rpm
dBA

dBA

dBA
dBA
°CDB
°CDB
kg

A
A
A
Hz/V






C
,

C
,

.
.
.
.
.
.
.
.
C
C
,
,


Stepless
C
,

C
,

C
,

C
,

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
,
,
,
,
,
,
,
,
, ,
,
, , , , , ,
,
,
,
, , , , , ,
,
,
,
, , , , , ,
,
,
,
, , , , , ,
Single pass shell & tube





.
.
.
.
.
.
.
.
.
.










High efficiency fin and tube type with integral subcooler
Asymmetric single screw compressor


Direct propeller






,
,
,
, , , ,











-~
-~
R-a








.mm
.mm
mm



























,
,
,
~//
.
Unit
Operation weight
Weight (XL)
Unit
Operation weight
Water heat
Type
exchanger
Water volume
Water flow rate Cooling Nom.
Water pressure drop Cooling Nom.
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Nom.
Speed
Sound power level (XS) Cooling
Nom.
Sound power level (XL) Cooling
Nom.
Sound pressure level (XS) Cooling
Nom.
Sound pressure level (XL) Cooling
Nom.
Operation range Water side
Cooling Min.~Max.
Air side
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage




.
C
,

.
.
.
,
,
,
,
,

.


,



,
EWAD-CZXR
Air cooled screw inverter chiller,
high efficiency,
reduced sound
EWAD-CZXS/XL/XR
Cooling only
Cooling capacity
Power input
Capacity control
EER
ESEER
IPLV
Dimensions
Weight
Nom.
Cooling
Nom.
Method
Minimum capacity
EWAD-CZXR
kW
kW



%
.
.
.
Unit
Height
Width
Depth
Unit
Operation weight
Water heat
Type
exchanger
Water volume
Water flow rate Cooling Nom.
Water pressure drop Cooling Nom.
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Nom.
Speed
Sound power level Cooling
Nom.
Sound pressure level Cooling
Nom.
Operation range Water side
Cooling Min.~Max.
Air side
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage
mm
mm
mm
kg
kg
,
,
,
l
l/s
kPa

.


l/s ,
rpm
dBA

dBA
°CDB
°CDB
kg

A
A
A
Hz/V












C
,

C
,

C
,

C
,

C
,

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
,
,
,
,
,
,
,
,
,
,
,
,
, , , , ,
,
,
,
, , , , , ,
Single pass shell & tube





.
.
.
.
.
.
.
.
.
.










High efficiency fin and tube type with integral subcooler
Asymmetric single screw compressor


Direct propeller






,
,
,
,
,
,






-~
-~
R-a








.mm
.mm
mm



























,
,
,
~//
.
.
.
.
.
.
.
.
.
.
.
.
.
C
C
,
,


Stepless
MicroTech III
C
,

.
.
.
,
,
,

.


,



,
315
EWAD-CFXS/XL
Air cooled screw chiller
with free cooling,
high efficiency,
standard/low sound




Free cooling chiller for space cooling and industrial processes
Stepless single-screw compressor
Optimised for use with R-a
Greater energy savings and reduced CO emissions during cold
season
 Wide operating range
 MicroTech III controller with superior control logic and easy
interface
Cooling only
Cooling capacity Nom.
Free cooling capacity Nom.
Mechanical capacity
Air temperature for free cooling %
Power input
Cooling
Nom.
EWAD-CFXS/XL 



C
C
C
C
C
C
C
kW  ()  ()  ()  () , () , () , () , () , () , () , ()
kW  ()  ()  ()  ()  ()
 (  ()  ()  () , () , ()
kW  ()  ()  ()  ()  ()  ()  ()  ()  ()  ()  ()
°C
-.
-.
.
.
.
.
.
.
.
.
.
kW  () /  () /  () /  () /  () /  () /  () /  () /  () /  () /  () /
. () . () . () . () . () . () . () . ()  ()  ()  ()
Capacity control
Method
Stepless
Minimum capacity
%
.
EER
. () / . () / . () / . () / . () / . () / . () / . () / . () / . () / . () /
. () . () . () . () . () . () . () . () . () . () . ()
ESEER
.
.
.
.
.
.
.
.
.
.
.
IPLV
.
.
.
.
.
.
.
.
.
.
.
Dimensions
Unit
Height
mm
,
Width
mm
,
Depth
mm ,
,
,
,
,
Weight (XS)
Unit
kg ,
,
,
,
,
,
, , ,
Operation weight
kg ,
,
,
,
,
,
, , ,
Weight (XL)
Unit
kg ,
,
,
,
,
,
,
,
,
Operation weight
kg ,
,
,
,
,
,
, , ,
Water heat
Type
Single pass shell & tube
exchanger
Water volume
l



,
,
,
Water flow rate Cooling Nom.
l/s . () / . () / . () / . () / . () / . () / . () / . () / . () / . () / . () /
. () . () . () . () . () . () . () . () . () . () . ()
Water pressure drop Cooling Nom.
kPa  () /  () /  () /  () /  () /  () /  () /  () /  () /  () /  () /
 ()  ()  ()  ()  ()  ()  ()  ()  ()  ()  ()
Air heat exchanger Type
High efficiency fin and tube type with integral subcooler
Compressor
Type
Asymmetric single screw compressor
Quantity

Fan
Type
Direct propeller
Quantity





Air flow rate
Nom.
l/s , ,
,
,
,
Speed
rpm

Sound power level (XS) Cooling
Nom.
dBA




Sound power level (XL) Cooling
Nom.
dBA




Sound pressure level (XS) Cooling
Nom.
dBA




Sound pressure level (XL) Cooling
Nom.
dBA


°CDB
-~
Operation range Water side
Cooling Min.~Max.
°CDB
-~
Air side
Cooling Min.~Max.
Refrigerant
Type
R-a
Charge
kg







Circuits
Quantity

Piping connections Evaporator water inlet/outlet (OD)
DNPN(.mm)
DNPN(.mm)
DNPN(mm)
Unit
Maximum starting current
A





,
,
,
Nominal running current (RLA) Cooling
A











Maximum running current
A










Power supply
Phase/Frequency/Voltage
Hz/V
~//
() Cooling: entering evaporator water temp. °C; leaving evaporator water temp. °C; ambient air temp. °C; full load operation. () Data is calculated at ambient air temperature °C, inlet water temperature °C.

EWAD-CFXR
Air cooled screw chiller
with free cooling,
high efficiency,
reduced sound
EWAD-CFXS/XL/XR
MicroTech III
Cooling only
Cooling capacity Nom.
Free cooling capacity Nom.
Mechanical capacity
Air temperature for free cooling %
Power input
Cooling
Nom.
EWAD-CFXR 




C
C
C
C
C
C
kW  ()  ()
 ()  ()  () , () , () , () , () , () , ()
kW  ()  ()  ()  ()  ()  ()  ()  ()  ()  ()  ()
kW  ()  ()  ()  ()  ()  ()  ()  ()  ()  ()  ()
°C
-.
-.
-.
-.
-.
-.
.
-.
-.
-.
-.
kW  () /  () /  () /  () /  () /  () /  () /  () /  () /  () /  () /
. () . () . () . () . () . () . () . () . ()  ()  ()
Capacity control
Method
Stepless
Minimum capacity
%
.
EER
. () / . () / . () / . () / . () / . () / . () / . () / . () / . () / . () /
. () . () . () . () . () . () . () . () .() . () . ()
ESEER
.
.
.
.
.
.
.
.
.
.
.
IPLV
.
.
.
.
.
.
.
.
.
.
Dimensions
Unit
Height
mm
,
Width
mm
,
Depth
mm ,
,
,
,
,
Weight
Unit
kg ,
,
,
,
,
,
,
,
,
Operation weight
kg ,
,
,
,
,
,
, , ,
Water heat
Type
Single pass shell & tube
exchanger
Water volume
l



,
,
,
Water flow rate Cooling Nom.
l/s . () / . () / . () / . () / . () / . () / . () / . () / . () / . () / . () /
. () . () . () . () . () . () . () . () . () . () . ()
Water pressure drop Cooling Nom.
kPa  () /  () /  () /  () /  () /  () /  () /  () /  () /  () /  () /
 ()
 ()  ()  ()  ()  ()  ()  ()  ()  ()  ()
Air heat exchanger Type
High efficiency fin and tube type with integral subcooler
Compressor
Type
Asymm single screw
Quantity

Fan
Type
Direct propeller
Quantity





Air flow rate
Nom.
l/s , ,
,
,
,
Speed
rpm

Sound power level Cooling
Nom.
dBA



Sound pressure level Cooling
Nom.
dBA





°CDB
-~
Operation range Water side
Cooling Min.~Max.
°CDB
-~
Air side
Cooling Min.~Max.
Refrigerant
Type
R-a
Charge
kg







Circuits
Quantity

Piping connections Evaporator water inlet/outlet (OD)
DNPN(.mm)
DNPN(.mm)
DNPN(mm)
Unit
Maximum starting current
A





,
,
,
Nominal running current (RLA) Cooling
A











Maximum running current
A










Power supply
Phase/Frequency/Voltage
Hz/V
~//
() Cooling: entering evaporator water temp. °C; leaving evaporator water temp. °C; ambient air temp. °C; full load operation. () Data is calculated at ambient air temperature °C, inlet water temperature °C.
317
ARGUE CARDS
Air cooled chiller with
inverter driven screw compressor:
EWAD-TZ (170-710 kW)
Why choose EWAD-TZ?
Benefits for the installer
› Easy to install: The EWAD-TZ chiller is set,
adjusted and tested in the factory
› Highly serviceable
› User-friendly smart controls which can be
integrated easily with building management
systems
Benefits for the consultant
› Advanced compressor technology with
in-built inverter and Variable Volume Ratio (VVR)
and new chiller controller software
› Multiple options available, e.g. rapid restart,
variable speed water pumps, smart energy meter,
EC fans
› Ideal for both new and retrofit projects:
same footprints of non-inverter unit with
higher efficiencies and performance
Benefits for the end user
› Rapid payback within 3 years of installation
› 50% reduction of energy consumption
› Designed for sound-sensitive environments
With almost 10 years of experience, Daikin is
pioneer in inverter applications for air cooled screw
chillers. Hundreds and hundreds inverter driven
single screw compressors are running on sites to
satisfy clients’ requests for efficiency to grant
the lowest running costs.
EWAD-TZ chiller with the new Daikin compressor...
Discharge port
VVR control
Inverter
Econ. & Liquid
injection ports
Liquid inlet
(VFD cooling)
Capacitors
Aluminium
cooling plate
Suction port
... is demonstrating that we will never stop
developing the most advanced technology
with highest quality level to offer the best chiller
experience to our customers.
318
Marketing tools
› Video
https://www.youtube.com/
watch?v=QQCYajRWZFQ
› Mini-site
http://www.daikineurope.com/
minisite/process-cooling-comfortcooling-chiller-EWAD-TZ
High efficiencies both at
full load and part load: EER up to 3.57
and ESEER up to 5.73
› New Daikin compressor with in-built
inverter and Variable Volume Ratio (VVR)
for an optimized efficiency
› New in-house chiller controller software with
dynamic condensing pressure management
and innovative economizer control logic
Rapid return on investment
› 3 years ROI compared to a non-inverter unit
for comfort cooling application
› 1 year ROI for process cooling
› Selection software
http://extranet.daikineurope.com/en/
software/downloads/default.jsp
Perfect comfort level
› Infinitely variable load regulation
› Precise leaving water temperature control thanks
to stepless regulation
Compact design
› More compact heat exchanger
with superior efficiencies
› Reduced electrical panel dimensions thanks
to the inverter compressor mounted
Lowest sound levels
› Down to 86 dB(A) sound power at full load
and even lower at part load thanks to fans
and compressors variable speed
› Quiet compressor thanks to special
acoustic executions
› Unique Daikin fans design with reduced noise
impact and vibrations
Unrivaled and proven reliability
› Extensive testing in laboratories,
Daikin factories and specific job sites
› Reduced energy demand without
compromising on reliability and performance
Extensive option list
›
›
›
›
Rapid restart after power failure
Variable speed water pumps
Integrated smart energy meter
EC fans
319
EWAD-TZSS/SR
Air cooled screw inverter chiller,
standard efficiency,
standard/reduced sound
 Optimized energy efficiency both at full and part load
conditions
 Stepless single-screw compressor
 Optimised for use with R-a
 Advanced compressor technology featuring integrated inverter
and variable volume ratio (VVR)
 Compact design for small footprint and minimized installation
space
 Low operating sound levels are achieved by the latest compressor
and fan design
 One or two truly independent refrigerant circuits for outstanding
reliability
Cooling only
Cooling capacity
Power input
Capacity control
EER
ESEER
IPLV
Dimensions
Weight (SS)
Nom.
Cooling
Nom.
Method
Minimum capacity
Unit
EWAD-TZSS/SR
kW
kW


.


.
%
.
.
.
.
.
.
.
.
Height
Width
Depth
Unit
Operation weight
Weight (SR)
Unit
Operation weight
Water heat
Type
exchanger
Water volume
Water flow rate Cooling Nom.
Water pressure drop Cooling Nom.
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Cooling Nom.
Speed
Cooling Nom.
Sound power level (SS) Cooling
Nom.
Sound power level (SR) Cooling
Nom.
Sound pressure level (SS) Cooling
Nom.
Sound pressure level (SR) Cooling
Nom.
Operation range Water side
Cooling Min.~Max.
Air side
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage

mm
mm
mm
kg
kg
kg
kg
l
l/s
kPa
l/s
rpm
dBA
dBA
dBA
dBA
°CDB
°CDB
kg
A
A
A
Hz/V


.


.















Stepless
.
.
.
. .
.
.
.
.
.















. . . .
.
.
.
.
.
. .
.
. . .
. .
. . . .
. . . .
.
. . . .
.
.
. . .
,
,
,
,
,
,
,
,
,
,
,
, , , , , , , , , , , , , ,
, , , , , , , , , , , , , ,
, , , , , , , , , , , , , ,
, , , , , , , , , , , , , ,
Plate heat exchanger
Single pass shell & tube










.
.
.
.
.
.
.
.
.
. . . . .














High efficiency fin and tube type with integral subcooler
Inverter driven single screw compressor


Direct propeller







, , , , ,
,
,
,
,
, ,


































-~
-~
R-a















.mm
.mm
.mm
.mm





























~//
EWAD-TZXS/XR
Air cooled screw inverter chiller,
high efficiency,
standard/reduced sound
EWAD-TZSS/SR/XS/XR
Cooling only
Cooling capacity
Power input
Capacity control
EER
ESEER
IPLV
Dimensions
Weight (XS)
Nom.
Cooling
Nom.
Method
Minimum capacity
Unit
EWAD-TZXS/XR
kW
kW


.
%
.
.
.
.
Height
Width
Depth
Unit
Operation weight
Weight (XR)
Unit
Operation weight
Water heat
Type
exchanger
Water volume
Water flow rate Cooling Nom.
Water pressure drop Cooling Nom.
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Nom.
Speed
Cooling Nom.
Sound power level (XS) Cooling
Nom.
Sound power level (XR) Cooling
Nom.
Sound pressure level (XS) Cooling
Nom.
Sound pressure level (XR) Cooling
Nom.
Operation range Water side
Cooling Min.~Max.
Air side
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage
mm
mm
mm
kg
kg
kg
kg
,
,
,
,
,
l
l/s
kPa

.


l/s ,
rpm
dBA 
dBA
dBA
dBA 
°CDB
°CDB
kg

A
A
A
Hz/V




.


.


.



MicroTech III





     
















Stepless
. . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. .
.
.
.
. . . . . . . . . . . .
.
,
,
,
,
,
,
,
,
,
,
, , , , , , , , , , , , ,
, , , , , , ,
,
, , , ,
, , , , , , ,
,
, , , ,
, , , , , , ,
,
, , , ,
Plate heat exchanger
Single pass shell & tube








.
.
.
.
.
.
.
.
.
.
.
.
.













High efficiency fin and tube type with integral subcooler
Inverter driven single screw compressor


Direct propeller






, , , , , , ,
,
, , , ,




























-~
-~
R-a















.mm
.mm
.mm



























~//
321
EWAD-TZPS/PR
Air cooled screw inverter chiller,
premium efficiency,
standard/reduced sound
 Premium energy efficiency both at full and part load
conditions
 Stepless single-screw compressor
 Optimised for use with R-a
 Advanced compressor technology featuring integrated inverter
and variable volume ratio (VVR)
 Compact design for small footprint and minimized installation
space
 Low operating sound levels are achieved by the latest compressor
and fan design
 One or two truly independent refrigerant circuits for outstanding
reliability
Cooling only
Cooling capacity
Power input
Capacity control
EER
ESEER
IPLV
Dimensions
Weight (PS)
Nom.
Cooling
Nom.
Method
Minimum capacity
Unit
EWAD-TZPS/PR
kW
kW
Height
Width
Depth
Unit
Operation weight
Weight (PR)
Unit
Operation weight
Water heat
Type
exchanger
Water volume
Water flow rate Cooling Nom.
Water pressure drop Cooling Nom.
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Cooling Nom.
Speed
Cooling Nom.
Sound power level (PS) Cooling
Nom.
Sound power level (PR) Cooling
Nom.
Sound pressure level (PS) Cooling
Nom.
Sound pressure level (PR) Cooling
Nom.
Operation range Water side
Cooling Min.~Max.
Air side
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage

%
mm
mm
mm
kg
kg
kg
kg
l
l/s
kPa
l/s
rpm
dBA
dBA
dBA
dBA
°CDB
°CDB
kg
A
A
A
Hz/V


.


.
EWAD-TZPS/PR


.


.


.


.
MicroTech III



  












Stepless
. . . . . .
.
.
.
.
.
.
.
.
. . .
. . . . . . .
. .
. . . . . .
.
.
.
. .
.
.
.
. .
.
.
.
.
,
,
,
,
,
,
, , , , , , , , , , , ,
, , , , , , , , , , , ,
, , , , , , , , , , , ,
, , , , , , , , , , , ,
Plate heat exchanger
Single pass shell & tube






.
.
.
.
.
.
.
.
.
.
.
.












High efficiency fin and tube type with integral subcooler
Inverter driven single screw compressor


Direct propeller




, ,
,
,
, , ,
,


















-~
-~
R-a














.mm
.mm
.mm

























~//






.
.
.
.
.
.
.
.
,
, ,
, ,
, ,
, ,

.

.


, ,








EWYQ-ADVP
Air cooled mini inverter
heat pump
 Inverter technology to ensure low sound values and leader-ofclass ESEER
 Wide operating range
 Easy ‘plug and play’ installation
 Single phase power supply and low starting currents make the
unit ideal for residential applications
 Built-in hydronic module: no buffer tank required and a standard
pump and main switch are included
EWYQ-ADVP
Heating & Cooling
Cooling capacity Nom.
Heating capacity Nom.
Power input
Cooling
Heating
Capacity control
Method
EER
COP
Dimensions
Unit
Weight
Nom.
Nom.
EWYQ-ADVP
kW
kW
kW
kW
EWYQADVP
. ()
. () / . ()
. ()
. () / . ()
. ()
. () / . ()
Height
Width
Depth
Unit
Operation weight
Water heat
Type
exchanger
Water flow rate Cooling Nom.
Heating Nom.
Air heat exchanger Type
Hydraulic components Expansion vessel Volume
Compressor
Type
Quantity
Fan
Type
Quantity
Sound power level Cooling
Nom.
Sound pressure
Cooling
Nom.
level
Heating
Nom.
Operation range Water side
Cooling Min.~Max.
Heating Min.~Max.
Air side
Cooling Min.~Max.
Heating Min.~Max.
Refrigerant
Type
Charge
Control
Circuits
Quantity
Water circuit
Piping connections diameter
Piping connections Water heat exchanger drain
Unit
Maximum running current
Power supply
Phase/Frequency/Voltage
mm
mm
mm
kg
kg
l/min
l/min
.
.
l
dBA
dBA
dBA
°CDB
°CDB
°CDB
°CDB
kg
inch
A
Hz/V
() Tamb °C - LWE °C (DT=°C) () DB/WB °C/°C - LWC °C (DT=°C) () DB/WB °C/°C - LWC °C (Dt=°C)

EWYQADVP
. ()
. () / . ()
. ()
. () / . ()
Inverter controlled
. ()
. () / . ()

,



Brazed plate
.
.
Tube type

Hermetically sealed swing compressor

Propeller fan




~
~
~
-~
R-A
.
Inverter

“ MBSP
/ SAE flare

~//
Digital controller
EWYQADVP
. ()
. () / . ()
. ()
. () / . ()
. ()
. () / . ()
.
.



EWYQ-ACV3/ACW1
Air cooled mini inverter
heat pump
 Inverter technology to ensure low sound values and leader-ofclass ESEER
 Wide operating range
 Built-in hydronic module: no buffer tank required and a standard
pump and main switch are included
 Easy ‘plug and play’ installation
 Single phase power supply for residential applications, three
phase power supply model available for light commercial
applications
EWYQ-ACV/ACW
Heating & Cooling
Cooling capacity Nom.
Heating capacity Nom.
Power input
Cooling
Heating
Capacity control
Method
EER
ESEER
COP
Dimensions
Unit
Digital controller
EWYQ-ACV/EWYQ-ACW
ACV
ACV
ACV
ACW
ACW
kW . () / . () . () / . ()
. () / . ()
. () / . ()
. () / . ()
kW . () / . () . () / . () . () / . () . () / . () . () / . ()
Nom.
kW . () / . () . () / . () . () / . () . () / . () . () / . ()
Nom.
kW . () / . () . () / . () . () / . () . () / . () . () / . ()
Inverter controlled
. () / . () . () / . () . () / . () . () / . () . () / . ()
.
.
.
.
.
. () / . () . () / . () . () / . () . () / . () . () / . ()
Height
mm
,
Width
mm
,
Depth
mm

Weight
Unit
kg

Water heat
Type
Brazed plate
exchanger
Quantity

Water volume
l
.
Nominal water Cooling
l/min
.
.
.
.
.
flow
Heating
l/min
.
.
.
.
.
Air heat exchanger Type
Hi-XSS
Hydraulic components Expansion vessel Volume
l

Compressor
Type
Hermetically sealed scroll compressor
Quantity

Fan
Type
Propeller fan
Quantity

Air flow rate
Cooling Nom.
m³/min



Heating Nom.
m³/min

Fan motor
Speed
Cooling Nom.
rpm

Heating Nom.
rpm

Steps

Sound power level Cooling
Nom.
dBA

Heating
Nom.
dBA

Sound pressure
Cooling
Nom.
dBA

level
Heating
Nom.
dBA

Cooling
Night quiet mode
dBA

Heating
Night quiet mode
dBA

°CDB
~
Operation range Water side
Cooling Min.~Max.
°CDB
~
Heating Min.~Max.
°CDB
~
Air side
Cooling Min.~Max.
°CDB
-~
Heating Min.~Max.
Refrigerant
Type
R-A
Charge
kg
.
Control
Electronic expansion valve
Circuits
Quantity

Water circuit
Piping connections diameter
inch
G /“ (female)
Piping
inch
/“
Power supply
Phase/Frequency/Voltage
Hz/V
~//
N~//
ACW
. () / . ()
. () / . ()
. () / . ()
. () / . ()
. () / . ()
.
. () / . ()
.
.




() Underfloor program: cooling Ta °C - LWE °C (Dt: °C); heating Ta DB/WB °C/°C - LWC °C (Dt: °C) () Fan coil program: cooling Ta °C - LWE °C ( Dt: °C); heating Ta DB/WB °C/°C - LWC °C ( Dt: °C )
325
EWYQ-BAWN/BAWP
Air cooled scroll inverter
heat pump





High efficiency with leader-of-class ESEER
Minimal starting currents and short payback times
No buffertank required for standard applications
Large operation range (ambient temperature up to °C)
A modbus gateway (RTD-W) can be installed per unit in order
allow the control and monitoring by a Daikin controller or a thirdparty BMS, which will increase further the efficiency of the system
 All systems that are connected with RTD-W can be controlled
and monitored centrally with the master/slave control kit: the
sequencing controller EKCC-W
EWYQ-BAWN/BAWP
Heating & Cooling
EWYQ-BAWN/BAWP
Cooling capacity Nom.
kW
Heating capacity Nom.
kW
Power input
Cooling
Nom.
kW
Heating
Nom.
kW
Capacity control
Method
Minimum capacity
%
EER
ESEER
COP
Dimensions
Unit
Height
mm
Width
mm
Depth
mm
Weight
Unit
kg
Operation weight
kg
Water heat
Type
exchanger
Water volume
l
l/min
Water flow rate Cooling Nom.
l/min
Heating Nom.
Water pressure drop Cooling Total
kPa
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Cooling Nom.
m³/min
Heating Nom.
m³/min
Sound power level Cooling
Nom.
dBA
°CDB
Operation range Water side
Cooling Min.~Max.
°CDB
Heating Min.~Max.
°CDB
Air side
Cooling Min.~Max.
°CDB
Heating Min.~Max.
Refrigerant
Type
Charge
kg
Control
Circuits
Quantity
Water circuit
Piping connections diameter
inch
Piping
inch
Unit
Maximum starting current
A
Maximum running current
A
Power supply
Phase/Frequency/Voltage
Hz/V
() EWYQ-BAWN: Naked version () EWYQ-BAWP: Verison with pump


. () / . ()
. () / . ()
. () / . ()
. () / . ()

. () / . ()
. () / . ()
. () / . ()
. () / . ()
BRCA




. () / . () . () / . () . () / . () . () / . ()
. () / . () . () / . () . () / . () . () / . ()
. () / . () . () / . () . () / . () . () / . ()
. () / . () . () / . () . () / . () . () / . ()
Inverter controlled

. () / . () . () / . () . () / . () . () / . () . () / . () . () / . ()
. () / . () . () / . () . () / . () . () / . () . () / . () . () / . ()
. () / . () . () / . () . () / . () . () / . () . () / . () . () / . ()
,
,
,
,










Brazed plate
.
.
.

















Hi-XSS
Hermetically sealed scroll compressor




Axial













~
~
-~
-~
R-A
.
.
.
Electronic expansion valve

-/“ (female)
“ (female)
-/“
-/“

.
.
.
.
.
.
.
.
.
.
.
N~//

. () / . ()
. () / . ()
. () / . ()
. () / . ()
. () / . ()
. () / . ()
. () / . ()
,


.








.
.
.
SEHVX-AAW + SERHQ-AAW1
Air cooled scroll inverter
heat pump, split version
 Hydronic module for indoor installation eliminating the need
for glycol
 Ideal for colder climates as the lack of glycol will allow for high
efficiencies
 Compact dimensions and limited pipework allow for installation
in very restricted spaces
 Easy transportation as separate units will fit in an elevator
SEHVX-AAW+SERHQ-AAW
Heating & Cooling
Cooling capacity
Heating capacity
Power input
Nom.
Max.
Nom.
Cooling
Heating
kW
kW
kW
kW
kW
Nom.
Nom.
EER
COP
Unit for indoor installation
Dimensions
Unit
Weight
Unit
Packed unit
Sound power level Nom.
Operation range Heating
Indoor
installation
Cooling
Refrigerant
SEHVX-AAW
mm
mm
mm
kg
kg
dBA
Ambient Min.~Max. °C~°CDB
°C
Water side Min.~Max.
Ambient Min.
°CDB
Max.
°CDB
°CDB
Ambient Min.~Max.
°C
Water side Min.~Max.
Power supply
Outdoor Unit
Dimensions
Unit
Water side Heat
exchanger
Current
Weight
Compressor
Fan
Unit
Packed unit
Quantity
Type
Type
Quantity
Air flow rate
SEHVXAAW/
SERHQAAW
.
.
. () / . ()
.
. () / . ()
.
. () / . ()
SEHVXAAW
SEHVXAAW
Height
Width
Depth
Type
Charge
Circuits
Quantity
Control
Piping connections diameter
Piping
Water pressure Cooling Nom.
drop
Heating Nom.
Total water volume
Type
Water volume
Water flow rate Heating Nom.
Cooling Nom.
Maximum
Cooling
running current Heating
Phase/Frequency/Voltage
Water circuit
SEHVXAAW/
SERHQAAW
.
.
. () / . ()
.
. () / . ()
.
. () / . ()
Height
Width
Depth
SEHVXAAW/
SEHVXAAW/
SERHQAAW+SERHQAAW SERHQAAW+SERHQAAW
.
.
.
.
. () / . ()
. () / . ()
.
.
. () / . ()
. () / . ()
.
.
. () / . ()
. () / . ()
SEHVXAAW
SEHVXAAW




,








-~
~


-~
~
R-A


Electronic expansion valve
kg
inch
inch
kPa
kPa
l
BRCA
G “/ (female)
-/“
G “ (female)
-/“


.


.
.


.
.
.


.
.


.


.
.


.


Brazed plate
l
l/min
l/min
A
A
Hz/V
SERHQ-AAW
mm
mm
mm
kg
kg
.
.
N~//
SERHQAAW
SERHQAAW
,

,

.
.

.
.

Hermetically sealed scroll compressor
Propeller fan
Cooling
Heating
Nom.
Nom.
m³/min
m³/min






() Heating Ta DB/WB /°C - LWC °C (DT=°C) () Heating Ta DB/WB /°C - LWC °C
327
EWYQ-F-XS/XL
Air cooled multi-scroll heat pump,
high efficiency,
standard/low sound
 Class A efficiency in heating mode
 Extended operation range: ambient temperatures from -°C up to
+°C in cooling mode and down to -°C in heating mode
  truly independent refrigerant circuits
 Reduced footprint thanks to the V-shaped frame (EWYQ-FXS/XL & EWYQ-F-XR)
 Reliable and efficient scroll compressors with high EER values
 Chiller series design entirely based on new European directives
(EN, EN)
 Top serviceability level thanks to reduced weight, compact
footprint and optimized components accessibility
 The unit can be equipped with a hydraulic module optimizing
installation time, space and cost
 Wide range of available options and accessories
 Inverter fans management for enhanced part load efficiencies
 Nordic kit option to improve the chiller working conditions in
heating mode
 MicroTech III controller with superior control logic and easy
interface
Heating & Cooling
EWYQ-F-XS/XL 











Cooling capacity Nom.
kW 











Heating capacity Nom.
kW












Power input
Cooling
Nom.
kW .
.
.
.








Heating
Nom.
kW .
.
.
.








Capacity control
Method
Step
Minimum capacity
%
.
.
EER
.
.
.
.
.
.
.
.
.
.
.
ESEER
.
.
.
.
.
.
.
.
.
.
.
.
COP
.
.
.
.
.
.
.
.
.
.
SCOP
.
.
.
.
.
.
.
.
.
.
.
IPLV
.
.
.
.
.
.
.
.
.
.
.
.
Dimensions
Unit
Height
mm
,
,
Width
mm
,
,
Depth
mm
,
,
,
,
,
,
Weight (XS)
Unit
kg ,
, , , ,
,
,
,
, , , ,
Operation weight
kg ,
, , , , , , , , , , ,
Weight (XL)
Unit
kg ,
, , , , , , , , , , ,
Operation weight
kg ,
, , ,
,
,
,
, ,
, , ,
Water heat
Type
Plate heat exchanger
exchanger
Water volume
l




Water flow rate Cooling Nom.
l/s
.
.
.
.
.
.
.
.
.
.
.
.
Heating Nom.
l/s
.
.
.
.
.
.
.
.
.
.
.
.
Water pressure Cooling Nom.
kPa












drop
Heating Nom.
kPa












Air heat exchanger Type
High efficiency fin and tube type with integral subcooler
Compressor
Type
Scroll compressor
Quantity


Fan
Type
Direct propeller
Quantity






Air flow rate
Nom.
l/s , ,
,
,
, ,
,
,
Speed
rpm

Sound power level (XS) Cooling
Nom.
dBA







Sound power level (XL) Cooling
Nom.
dBA







Sound pressure level (XS) Cooling
Nom.
dBA








Sound pressure level (XL) Cooling
Nom.
dBA






°CDB
-~
Operation range Water side
Cooling Min.~Max.
°CDB
~
Heating Min.~Max.
°CDB
-~
Air side
Cooling Min.~Max.
°CDB
-~
Heating Min.~Max.
Refrigerant
Type
R-A
Charge
kg










Circuits
Quantity

Piping connections Evaporator water inlet/outlet (OD)
.“
“
Unit
Maximum starting current
A 











Nominal running current (RLA) Cooling
A












Maximum running current
A












Power supply
Phase/Frequency/Voltage
Hz/V
~//

EWYQ-F-XR
Air cooled multi-scroll heat pump,
high efficiency,
reduced sound
EWYQ-F-XS/XL/XR
MicroTech III
Heating & Cooling
EWYQ-F-XR 










Cooling capacity Nom.
kW











Heating capacity Nom.
kW











Power input
Cooling
Nom.
kW .
.
.
.
.






Heating
Nom.
kW .
.
.
.







Capacity control
Method
Step
Minimum capacity
%
.
.
EER
.
.
.
.
.
.
.
.
.
.
.
ESEER
.
.
.
.
.
.
.
.
.
.
.
COP
.
.
.
.
.
.
.
.
.
SCOP
.
.
.
.
.
.
.
.
.
.
IPLV
.
.
.
.
.
.
.
.
.
.
.
Dimensions
Unit
Height
mm
,
,
Width
mm
,
,
Depth
mm
,
,
,
,
,
Weight
Unit
kg ,
, , , , , , , , , ,
Operation weight
kg ,
, , ,
,
,
,
, ,
, ,
Water heat
Type
Plate heat exchanger
exchanger
Water volume
l




Water flow rate Cooling Nom.
l/s
.
.
.
.
.
.
.
.
.
.
.
Heating Nom.
l/s
.
.
.
.
.
.
.
.
.
.
.
Water pressure Cooling Nom.
kPa











drop
Heating Nom.
kPa











Air heat exchanger Type
High efficiency fin and tube type with integral subcooler
Compressor
Type
Scroll compressor
Quantity


Fan
Type
Direct propeller
Quantity





Air flow rate
Nom.
l/s , ,
,
,
, ,
,
Speed
rpm

Sound power level Cooling
Nom.
dBA







Sound pressure level Cooling
Nom.
dBA







°CDB
-~
Operation range Water side
Cooling Min.~Max.
°CDB
~
Heating Min.~Max.
°CDB
-~
Air side
Cooling Min.~Max.
°CDB
-~
Heating Min.~Max.
Refrigerant
Type
R-A
Charge
kg









Circuits
Quantity

Piping connections Evaporator water inlet/outlet (OD)
.“
“
Unit
Maximum starting current
A 










Nominal running current (RLA) Cooling
A











Maximum running current
A











Power supply
Phase/Frequency/Voltage
Hz/V
~//





.
.
.
.
.
,
,
,
.
.



,




329
EWYQ-GZXS
Air cooled multi-scroll
inverter heat pump,
high efficiency,
standard sound
 High efficiency DC inverter scroll compressors
 Advanced compressor and fan design resulting in low operating
sound levels
 Dual independent refrigerant circuit for built-in redundancy and
reliable operation
 Reduced footprint thanks to the V-shaped frame (EWYQGZXS/
XR)
 Wide operating range in both heating and cooling mode
 MicroTech III controller with superior control logic and easy
interface
Heating & Cooling
EWYQ-GZXS
Cooling capacity Nom.
kW
Heating capacity Nom.
kW
Power input
Cooling
Nom.
kW
Heating
Nom.
kW
Capacity control
Method
Minimum capacity
%
EER
ESEER
COP
SCOP
IPLV
Dimensions
Unit
Height
mm
Width
mm
Depth
mm
Weight
Unit
kg
Operation weight
kg
Water heat
Type
exchanger
Water volume
l
Water flow rate Cooling Nom.
l/s
Heating Nom.
l/s
Water pressure Cooling Nom.
kPa
drop
Heating Nom.
kPa
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Nom.
l/s
Speed
rpm
Sound power level Cooling
Nom.
dBA
Sound pressure level Cooling
Nom.
dBA
°CDB
Operation range Water side
Cooling Min.~Max.
°CDB
Heating Min.~Max.
°CDB
Air side
Cooling Min.~Max.
°CDB
Heating Min.~Max.
Refrigerant
Type
Charge
kg
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
A
Nominal running current (RLA) Cooling
A
Maximum running current
A
Power supply
Phase/Frequency/Voltage
Hz/V




.
.



.
.
.
.
.
.
.
.
,
,
,
,
,
.
.
.
.
.
.

.
.




,




.“







Stepless
.
.
.
.
.
.










.
.
.
.
.
.
.
.
.
.
.
.
,
,
,
,
,
,
,
,
Plate heat exchanger



.
.
.
.
.
.






High efficiency fin and tube type with integral subcooler
DC Inverter Scroll


Direct propeller


,
,




-~
~
-~
-~
R-A



.“







~//
,
,
,
,

.
.






EWYQ-GZXR
Air cooled multi-scroll
inverter heat pump,
high efficiency,
reduced sound
EWYQ-GZXS/XR
Heating & Cooling
EWYQ-GZXR
Cooling capacity Nom.
kW
Heating capacity Nom.
kW
Power input
Cooling
Nom.
kW
Heating
Nom.
kW
Capacity control
Method
Minimum capacity
%
EER
ESEER
COP
SCOP
IPLV
Dimensions
Unit
Height
mm
Width
mm
Depth
mm
Weight
Unit
kg
Operation weight
kg
Water heat
Type
exchanger
Water volume
l
Water flow rate Cooling Nom.
l/s
Heating Nom.
l/s
Water pressure Cooling Nom.
kPa
drop
Heating Nom.
kPa
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Quantity
Air flow rate
Nom.
l/s
Speed
rpm
Sound power level Cooling
Nom.
dBA
Sound pressure level Cooling
Nom.
dBA
°CDB
Operation range Water side
Cooling Min.~Max.
°CDB
Heating Min.~Max.
°CDB
Air side
Cooling Min.~Max.
°CDB
Heating Min.~Max.
Refrigerant
Type
Charge
kg
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
A
Nominal running current (RLA) Cooling
A
Maximum running current
A
Power supply
Phase/Frequency/Voltage
Hz/V



.
.



.
.
.
.
.
.
.
.
,
,
,
,
,
.
.
.
.
.

.
.




,




.“


MicroTech III





Stepless
.
.
.
.
.
.










.
.
.
.
.
.
.
.
.
.
.
.
,
,
,
,
,
,
,
,
,
,
,
Plate heat exchanger



.
.
.
.
.
.






High efficiency fin and tube type with integral subcooler
DC Inverter Scroll


Direct propeller


,
,





-~
~
-~
-~
R-A



.“







~//
,
,

.
.






331
EWYD-BZSS
Air cooled screw inverter
heat pump,
standard efficiency,
standard sound
 Optimised for use with R-a
 Ideal solution for commercial comfort cooling and/or heating
applications
 Standard electronic expansion valve
 DX shell and tube evaporator – one pass refrigerant side to
minimize pressure drops
 Low starting current
 Optimised defrost cycles
 Optimum ESEER values
 Partial and total heat recovery option available
 PID microprocessor control
 Power factor up to .
 - truly independent refrigerant circuits
Heating & Cooling
EWYD-BZSS 












Cooling capacity Nom.
kW 












Heating capacity Nom.
kW 












Power input
Cooling
Nom.
kW .












Heating
Nom.
kW .












Capacity control
Method
Stepless
Minimum capacity
%
.
.
EER
.
.
.
.
.
.
.
.
.
.
.
.
.
ESEER
.
.
.
.
.
.
.
.
.
.
.
.
COP
.
.
.
.
.
.
.
.
.
.
.
.
.
IPLV
.
.
.
.
.
.
.
.
.
.
.
.
Dimensions
Unit
Height
mm
,
,
Width
mm
,
Depth
mm
,
,
,
,
Weight
Unit
kg , , ,
,
, ,
,
, ,
,
Operation weight
kg , , ,
,
, ,
,
, , , ,
Water heat
Type
Single pass shell & tube
exchanger
Water volume
l






Water flow rate Cooling Nom.
l/s .
.
.
.
.
.
.
.
.
.
.
.
.
Heating Nom.
l/s .
.
.
.
.
.
.
.
.
.
.
.
.
Water pressure Cooling Nom.
kPa













drop
Heating Nom.
kPa













Air heat exchanger Type
High efficiency fin and tube type with integral subcooler
Compressor
Type
Single screw compressor
Quantity


Fan
Type
Direct propeller
Quantity




Air flow rate
Nom.
l/s , , ,
,
, ,
,
, , , ,
Speed
rpm

Sound power level Cooling
Nom.
dBA



Sound pressure level Cooling
Nom.
dBA



°CDB
-~
Operation range Water side
Cooling Min.~Max.
°CDB
~
Heating Min.~Max.
°CDB
-~
Air side
Cooling Min.~Max.
°CDB
-~
Heating Min.~Max.
Refrigerant
Type
R-a
Charge
kg









Circuits
Quantity


Piping connections Evaporator water inlet/outlet (OD)
.mm
.mm
Unit
Maximum starting current
A








Nominal running current (RLA) Cooling
A 












Maximum running current
A









Power supply
Phase/Frequency/Voltage
Hz/V
~//

EWYD-BZSL
Air cooled screw inverter
heat pump,
standard efficiency,
low sound
EWYD-BZSS/SL
MicroTech II
Heating & Cooling
EWYD-BZSL 












Cooling capacity Nom.
kW 












Heating capacity Nom.
kW 












Power input
Cooling
Nom.
kW .
.











Heating
Nom.
kW .












Capacity control
Method
Stepless
Minimum capacity
%
.
.
EER
.
.
.
.
.
.
.
.
.
.
.
.
.
ESEER
.
.
.
.
.
.
.
.
.
.
.
.
.
COP
.
.
.
.
.
.
.
.
.
.
.
.
.
IPLV
.
.
.
.
.
.
.
.
.
.
.
.
.
Dimensions
Unit
Height
mm
,
,
Width
mm
,
Depth
mm
,
,
,
,
Weight
Unit
kg , , ,
,
, ,
,
, ,
,
Operation weight
kg , , ,
,
, ,
,
, , , ,
Water heat
Type
Single pass shell & tube
exchanger
Water volume
l






Water flow rate Cooling Nom.
l/s .
.
.
.
.
.
.
.
.
.
.
.
.
Heating Nom.
l/s .
.
.
.
.
.
.
.
.
.
.
.
.
Water pressure Cooling Nom.
kPa













drop
Heating Nom.
kPa













Air heat exchanger Type
High efficiency fin and tube type with integral subcooler
Compressor
Type
Single screw compressor
Quantity


Fan
Type
Direct propeller
Quantity




Air flow rate
Cooling Nom.
l/s , , ,
,
, ,
,
, , , ,
Speed
Cooling Nom.
rpm

Sound power level Cooling
Nom.
dBA



Sound pressure level Cooling
Nom.
dBA


°CDB
-~
Operation range Water side
Cooling Min.~Max.
°CDB
~
Heating Min.~Max.
°CDB
-~
Air side
Cooling Min.~Max.
°CDB
-~
Heating Min.~Max.
Refrigerant
Type
R-a
Charge
kg









Circuits
Quantity


Piping connections Evaporator water inlet/outlet (OD)
.mm
.mm
Unit
Maximum starting current
A 









Nominal running current (RLA) Cooling
A 












Maximum running current
A 









Power supply
Phase/Frequency/Voltage
Hz/V
~//
333
ERAD-E-SS
Air cooled screw condensing unit,
standard efficiency,
standard sound




One refrigerant circuit with single screw compressor
Compact design
Large operation range (ambient temperature down to -°C)
Extensive option list (heat recovery option available)
Cooling only
Cooling capacity
Power input
Capacity control
EER
Dimensions
Weight
Nom.
Cooling
Nom.
Method
Minimum capacity
Unit
ERAD-E-SS
kW
kW
Height
Width
Depth
Unit
Operation weight
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Air flow rate
Nom.
Quantity
Speed
Cooling Nom.
Sound power level Cooling
Nom.
Sound pressure level Cooling
Nom.
Operation range Saturated suction temp.
Condenser inlet temp.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage



.


.


.
.
.
.
%
mm
mm
mm
kg
kg
l/s
rpm
dBA
dBA
°C
°C
kg
A
A
A
Hz/V


.




.
.
Stepless
.
.
.


.









.
.
.
.
.
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
High efficiency fin and tube type with integral subcooler
Single screw compressor

Direct propeller
,
,
,
,
,
,
,
,












-~
-~
R-a










mm
.mm

























~//
ERAD-E-SL
Air cooled screw condensing unit,
standard efficiency,
low sound
ERAD-E-SS/SL
Cooling only
Cooling capacity
Power input
Capacity control
EER
Dimensions
Weight
Nom.
Cooling
Nom.
Method
Minimum capacity
Unit
ERAD-E-SL
kW
kW
Height
Width
Depth
Unit
Operation weight
Air heat exchanger Type
Compressor
Type
Quantity
Fan
Type
Air flow rate
Nom.
Quantity
Speed
Cooling Nom.
Sound power level Cooling
Nom.
Sound pressure level Cooling
Nom.
Operation range
Saturated suction temp
Condenser inlet temp
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage


.


.


.
.
.
.
%
mm
mm
mm
kg
kg
l/s
,
,
,
,
,

rpm
dBA
dBA
°C
°C

kg

A
A
A
Hz/V








.




.
.
Stepless
.
.
.
MicroTech III


.









.
.
.
.
,
,
,
,
,
,
,
,
,
,
,
,
,
High efficiency fin and tube type with integral subcooler
Single screw compressor

Direct propeller
,
,
,
,
,
,











-~
-~
R-a








mm
.mm




















~//
335
EWWQ-B-SS
Water cooled screw chiller,
standard efficiency,
standard sound
 All models are PED pressure vessel approved
  or  stepless single-screw compressors
 One or two truly independent refrigerant circuits for outstanding
reliability
 Shell and tube heat exchanger
 Optimised for use with R-A
 Standard electronic expansion valve
 Compact design
 Partial heat recovery available
 MicroTech III controller with superior control logic and easy
interface
Cooling only
Cooling capacity
Power input
Capacity control
EWWQ-B-SS          C C C C C C C C C C
kW          , , , , , , , , , ,
kW .                  
Stepless
%
.
. .
.
.
.
EER
.
. . . . . . . . . . . . . . . . .
ESEER
. .
.
. . . . . . . . . . . . . . .
IPLV
.
.
. . . . . . . .
.
. . . . . .
,
, ,
,
,
Dimensions
Unit
Height
mm
,
, , , ,
,
,
Width
mm
,
,
, , , ,
,
,
,
Depth
mm
,
, , , , , , ,
Weight
Unit
kg , , , , , , , , , , , , , , , , , , ,
Operation weight
kg , , , , , , , , , , , , , , , , , , ,
Water heat
Type
Single pass shell and tube
exchanger Water volume
l           


  
evaporator
Water flow rate Nom.
l/s . . . . . . . . . . . . . . . . . . .
Water pressure drop Cooling Nom.
kPa                   
Water heat
Type
Single pass shell and tube
exchanger Water flow rate Nom.
l/s . . . . . . . . . . . . . . . . . . .
condenser
Water flow rate  Nom.
l/s
. - . . - . .
.
. . . . .
Water pressure drop Cooling Nom.
kPa           





Water pressure drop  Cooling Nom.
kPa

 
 

 

 
Compressor
Type
Single screw compressor
Quantity






Sound power level Cooling
Nom.
dBA  

 







Sound pressure level Cooling
Nom.
dBA  

 






°CDB
-~
Operation range Evaporator
Cooling Min.~Max.
°CDB
~
Condenser
Cooling Min.~Max.
Refrigerant
Type
R-A
Charge
kg      

   


  
Circuits
Quantity






Piping connections Evaporator water inlet/outlet
mm
.
.

Condenser water inlet/outlet
inch





Unit
Maximum starting current
A

  







Nominal running current (RLA) Cooling
A                   
Maximum running current
A                   
Power supply
Phase/Frequency/Voltage
Hz/V
~//

Nom.
Cooling
Nom.
Method
Minimum capacity
EWWQ-B-XS
Water cooled screw chiller,
high efficiency,
standard sound
EWWQ-B-SS/XS
Cooling only
Cooling capacity
Power input
Capacity control
EWWQ-B-XS       C C C C C C
kW       , , , , , ,
kW .           
Stepless
%
.
. .
EER
. . . .
.
. . . . . .
ESEER
. . . . . . . .
.
. .
IPLV
.
. . . . . . . . . .
Dimensions
Unit
Height
mm
,
, , , ,
,
Width
mm
,
, , , , ,
Depth
mm
,
,
, , ,
,
Weight
Unit
kg , , , , , , , , , , , ,
Operation weight
kg , , , , , , , , , , , ,
Water heat
Type
Single pass shell and tube
exchanger Water volume
l          

evaporator
Water flow rate Nom.
l/s . . . . . . . . . . . .
Water pressure drop Cooling Nom.
kPa 










Water heat
Type
Single pass shell and tube
exchanger Water flow rate Nom.
l/s . . . . . . . . . . . .
condenser
Water flow rate  Nom.
l/s
.
. .
.
Water pressure drop Cooling Nom.
kPa 











Water pressure drop  Cooling Nom.
kPa




Compressor
Type
Single screw compressor
Quantity



Sound power level Cooling
Nom.
dBA  

   


Sound pressure level Cooling
Nom.
dBA 








°CDB
-~
Operation range Evaporator
Cooling Min.~Max.
°CDB
~
Condenser
Cooling Min.~Max.
Refrigerant
Type
R-A
Charge
kg            
Circuits
Quantity



mm
.
.
 . 
.
Piping connections Evaporator water inlet/outlet
Condenser water inlet/outlet
inch






Unit
Maximum starting current
A


 


Nominal running current (RLA) Cooling
A            
Maximum running current
A            
Power supply
Phase/Frequency/Voltage
Hz/V
~//
Nom.
Cooling
Nom.
Method
Minimum capacity
MicroTech III
C C C C C
, , , , ,
    
.
. . . . .
. . . . .
. . . . .
,
,
,
,
,
, , ,
, , , , ,
  

. . . . .



 
. . . . .
. . . . .
























 
 






337
EWWP-KBW1N
Water cooled scroll chiller
 One of the most compact units on the market:
mmxmmxmm
 Standard integrated: main switch, water filter, flow switch, air
purge, pressure ports
 Daikin scroll compressor
 Optimised for use with R-C
 Electronic DDC controller
 Low operating sound level
 Low energy consumption
 Extension possible up to kW
 Low refrigerant volume
 Easy installation and maintenance
 Stainless steel plate heat exchanger
 Remote cooling or heating selection
 Water/water heat pump, with water reversibility
 Compatible with hydraulic module EHMC (see next page)
 μC²SE controller featuring top-of-the-range performance and user
friendliness
Heating only & Cooling only
EWWP-KBWN
Cooling capacity Nom.
kW
Heating capacity Nom.
kW
Power input
Cooling
Nom.
kW
Heating
Nom.
kW
Capacity steps number
EER
COP
Dimensions
Unit
HeightxWidthxDepth
mm
Weight
Unit
kg
Water heat
Type
exchanger Minimum water volume in the system
l
evaporator
Water flow rate Min.
l/min
Nom.
l/min
Max.
l/min
Water heat
Type
exchanger Water flow rate Min.
l/min
condenser
Nom.
l/min
Max.
l/min
Compressor
Type
Quantity
Compressor 
Quantity
Sound power level Cooling
Nom.
dBA
°CDB
Operation range Evaporator
Cooling Min.~Max.
°CDB
Condenser
Cooling Min.~Max.
Refrigerant
Type
Charge
kg
Control
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Evaporator water drain
Condenser water inlet/outlet (OD)
Power supply
Phase/Frequency/Voltage
Hz/V


.
.
.
.
 
. .
. .
. .
. .


. .
.
. . .
. . . . . . .
xx
xx,
      







.

.
.
.
.

.
.
.
.
EWWP-KBWN

.
.
.
.

.
.
.
.

.

.
.

.

.
.
μC²SE
       
       
       
. . . . . . . .
. . . . . . . .


. . . . .
.
. . .
. . . . . .
.
. .
,xx,
,xx,
         
Brazed plate
      




               
               
              , ,
Brazed plate


             
               
           , , , , ,
Hermetically sealed scroll compressor





















 
-~
~
R-C

. .
.
.
.
. .
.
. .
Thermostatic expansion valve




FBSP mm
FBSP mm
 x  x FBSP mm
 x  x FBSP mm
Field installation
FBSP mm
FBSP mm
 x  x FBSP mm
 x  x FBSP mm
N~//



.
.
.
.
,



,


,


.
EWWP-KBW1N
Water cooled scroll chiller
Combination table
Selection table
Capacity index
Cooling capacity (kW)
Heating capacity (kW)
1 Module (KB-series)
2 Modules (KB-series)
014 022 028 035 045 055 065 090 100 110 120 130
12.9 21.4 27.8 32.3 42.8 55.7 64.7 85.7 98.6 112 121 130
16.7 27.5 35.6 41.5 55.0 71.7 83.0 110 127 143 155 166
Unit
+
Control
(Factory mounted)
Modular units
(Controller available as accessory)
Control
(Kit)
EWWP014KBW1N
EWWP022KBW1N
EWWP028KBW1N
EWWP035KBW1N
EWWP045KBW1N
EWWP055KBW1N
EWWP065KBW1N
EWWP045KAW1M
EWWP055KAW1M
EWWP065KAW1M
ECB2MUW
ECB3MUW
1
-
1
-
1
-
1
-
1
-
1
-
1
-
2
1
-
1
1
1
-
2
1
-
1
1
1
-
2
1
-
145
141
182
2
1
1
3 Modules (KB-series)
155 165 175 185
154 167 176 185
198 215 226 237
1
2
1
3
1
2
1
1
1
2
1
195
194
249
3
1
For example: for a 121 kW HP system, select : EWWP055KBW1N + EWWP065KBW1N
EHMC
Hydraulic Module
›
›
›
›
›
›
›
Accessory for EWWP-KBW1N chillers
3 models available
100 l tank for all sizes
Freeze up protection
High static pump (option)
Standard drain kit (for indoor use)
Standard dual pressure ports
(before & behind the pump)
mH2O
Legends
55
Pump characteristics
50
1. EHMC30AV1080
45
2. EHMC10AV1080 &
1
40
EHMC15AV1080
3. EHMC30AV1010
35
2
30
4. EHMC10AV1010 &
EHMC15AV1010
3
25
Hydraulic module
20
+ filter pressures losses
4
15
5
10
EHMC15/30AV1080
6
5
EHMC-AV
5. EHMC15/30AV1010 &
6. EHMC10AV1010 &
EHMC10AV1080
0
0 20
40 60 80 100 120 140 160 180 200 220 240
260
WF (l/min)
10
EHMC-AV
Nominal flow
Nominal ESP
Nominal input
Dimensions (HxWxD)
Machine weight
Sound power
Sound pressure
Power supply
Operation range
Water side
Air side
Piping connections Water inlet/outlet
Drain connection
1010
l/min
mH2O
W
mm
kg
dBA
dBA
V1
°C
°CDB
15
1080
1010
62
17
630
1010
88
34
1,050
15
650
101
102
1,284x635x688
99
30
1080
27
1,070
1,284x635x688
104
63
52
63
52
1~/230V/50Hz
-10°C ~ 55°C
-10°C ~ 43°C
1" BSPF
2" BSPF
1/2"
1080
187
10
1,070
27
2,090
1,284x635x688
105
111
63
52
2-1/2" BSPF
339
EWWD-G-SS
Water cooled screw chiller,
standard efficiency,
standard sound






All models are PED pressure vessel approved
Stepless single-screw compressor
Optimised for use with R-a
- truly independent refrigerant circuits
Standard electronic expansion valve
DX shell and tube evaporator – one pass refrigerant side for easy
oil circulation and return
 Partial and total heat recovery option available
 MicroTech III controller with superior control logic and easy
interface
Heating only & Cooling only
EWWD-G-SS
Cooling capacity Nom.
kW
Heating capacity Nom.
kW
Power input
Cooling
Nom.
kW
Heating
Nom.
kW
Capacity control
Method
Minimum capacity
%
EER
ESEER
COP
IPLV
Dimensions
Unit
Height
mm
Width
mm
Depth
mm
Weight
Unit
kg
Operation weight
kg
Water heat
Type
exchanger Water volume
l
evaporator
Water flow rate Nom.
l/s
Water pressure drop Cooling Total
kPa
Water heat
Type
exchanger Water flow rate Nom.
l/s
condenser
Water flow rate  Nom.
l/s
Water pressure drop Cooling Nom.
kPa
Water pressure drop  Cooling Nom.
kPa
Compressor
Type
Quantity
Sound power level Cooling
Nom.
dBA
Sound pressure level Cooling
Nom.
dBA
°CDB
Operation range Evaporator
Cooling Min.~Max.
°CDB
Condenser
Cooling Min.~Max.
Refrigerant
Type
Charge
kg
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Condenser water inlet/outlet (OD)
Unit
Maximum starting current
A
Nominal running current (RLA) Cooling
A
Maximum running current
A
Power supply
Phase/Frequency/Voltage
Hz/V




.
.



.
.
.
.
.
.
.
.
.
.



.
.



.
.






.
.
.
.
Stepless





.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
,
,

.


.

.
.
,
,







.
.
.
.
.
.
.
.
.
.
.
.
.
,

,
.

.

.
.








.
.
.
.
,

,
,
,





-
,
,
,
,
,
,
Single pass shell and tube


.
.
.



Single pass shell and tube
.
.
.
.
.





Single screw compressor



,
,
,

.

.
.

.
.


.
.



.
.





-~
~
R-a




.
.
.mm
“

















~//








EWWD-G-XS
Water cooled screw chiller,
high efficiency,
standard sound
EWWD-G-SS/XS
Heating only & Cooling only
EWWD-G-XS
Cooling capacity Nom.
kW
Heating capacity Nom.
kW
Power input
Heating
Nom.
kW
Capacity control
Method
Minimum capacity
%
EER
ESEER
COP
IPLV
Dimensions
Unit
Height
mm
Width
mm
Depth
mm
Weight
Unit
kg
Operation weight
kg
Water heat
Type
exchanger Water volume
l
evaporator
Water flow rate Nom.
l/s
Water pressure drop Cooling Total
kPa
Water heat
Type
exchanger Water flow rate Nom.
l/s
condenser
Water flow rate  Nom.
l/s
Water pressure drop Cooling Nom.
kPa
Water pressure drop  Cooling Nom.
kPa
Compressor
Type
Quantity
Sound power level Cooling
Nom.
dBA
Sound pressure level Cooling
Nom.
dBA
°CDB
Operation range Evaporator
Cooling Min.~Max.
°CDB
Condenser
Cooling Min.~Max.
Refrigerant
Type
Charge
kg
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Condenser water inlet/outlet (OD)
Unit
Maximum starting current
A
Nominal running current (RLA) Cooling
A
Maximum running current
A
Power supply
Phase/Frequency/Voltage
Hz/V



.



.
.
.
.
.
.
.
.
.
MicroTech III



.



.






.
.
Stepless



.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
,
,

.


.

.
.


-




.
.
.
.
.
.
.
.
.
.
.
.
,

,
,
,
-




.
.
.
.
.
,

,
,
,




,
,
,
,
,
,
Single pass shell and tube



.
.
.
.
.





Single pass shell and tube
.
.
.
.
.
.
.




Single screw compressor



,
,
,
,

.

.

.
.
.


.

.
.





-~
~
R-a



.





.
.mm
“

















~//








341
EWWD-I-SS
Water cooled screw chiller,
standard efficiency,
standard sound






All models are PED pressure vessel approved
Stepless single-screw compressor
Optimised for use with R-a
One, two or three truly independent refrigerant circuits
Standard electronic expansion valve
DX shell and tube evaporator – one pass refrigerant side to
minimize pressure drops
 Partial and total heat recovery option available
 MicroTech III controller with superior control logic and easy
interface
Heating only & Cooling only
EWWD-I-SS
Cooling capacity Nom.
kW
Heating capacity Nom.
kW
Power input
Cooling
Nom.
kW
Heating
Nom.
kW
Capacity control
Method
Minimum capacity
%
EER
ESEER
COP
IPLV
Dimensions
Unit
Height
mm
Width
mm
Depth
mm
Weight
Unit
kg
Operation weight
kg
Water heat
Type
exchanger Water volume
l
evaporator
Water flow rate Nom.
l/s
Water pressure Cooling Nom.
kPa
drop
Heating Nom.
kPa
Water heat
Type
exchanger Water flow rate Nom.
l/s
condenser
Water flow rate  Nom.
l/s
Water flow rate  Nom.
l/s
Water pressure Cooling Nom.
kPa
drop
Heating Nom.
kPa
Water pressure drop  Cooling Nom.
kPa
Water pressure drop  Cooling Nom.
kPa
Compressor
Type
Quantity
Sound power level Cooling
Nom.
dBA
Sound pressure level Cooling
Nom.
dBA
°CDB
Operation range Evaporator
Cooling Min.~Max.
°CDB
Condenser
Cooling Min.~Max.
Refrigerant
Type
Charge
kg
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Condenser water inlet/outlet (OD)
Unit
Maximum starting current
A
Nominal running current (RLA) Cooling
A
Maximum running current
A
Power supply
Phase/Frequency/Voltage
Hz/V




.
.



.
.





.
. .
. .
. .
. .
,
,
,
, , ,
, , ,
.
.
.
.


. . .
  
  
. . .






-










  
  










     C C C C C C C C
     , , , , , , , ,
  , , , , , , , , , , ,
            
            
Stepless
.
.
. . . . . . . . . . . . . . .
. . . . . . . . .
.
. . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . .
.
. .
,
,
,
,
,
,
, , , , , , , , , , , , , , ,
, , , , , , , , , , , , , , ,
Single pass shell and tube
     

  

. . . . . . . . . . . . . . .
   
    
    

   
    
    

Single pass shell and tube
. . . . . . . .
.
.
.
.
. . . . . . .
.
.
.
.
. . . .
.



   




  

 





 







   

Single screw compressor



 




 




-~
~
R-a
   


      


.mm
.mm
“
  


 



              
              
~//
EWWD-I-XS
Water cooled screw chiller,
high efficiency,
standard sound
EWWD-I-SS/XS
Heating only & Cooling only
EWWD-I-XS
Cooling capacity Nom.
kW
Heating capacity Nom.
kW
Power input
Cooling
Nom.
kW
Heating
Nom.
kW
Capacity control
Method
Minimum capacity
%
EER
ESEER
COP
IPLV
Dimensions
Unit
Height
mm
Width
mm
Depth
mm
Weight
Unit
kg
Operation weight
kg
Water heat
Type
exchanger Water volume
l
evaporator
Water flow rate Nom.
l/s
Water pressure Cooling Nom.
kPa
drop
Heating Nom.
kPa
Water heat
Type
exchanger Water flow rate Nom.
l/s
condenser
Water flow rate  Nom.
l/s
Water pressure Cooling Nom.
kPa
drop
Heating Nom.
kPa
Water pressure drop  Cooling Nom.
kPa
Compressor
Type
Quantity
Sound power level Cooling
Nom.
dBA
Sound pressure level Cooling
Nom.
dBA
°CDB
Operation range Evaporator
Cooling Min.~Max.
°CDB
Condenser
Cooling Min.~Max.
Refrigerant
Type
Charge
kg
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Condenser water inlet/outlet (OD)
Unit
Maximum starting current
A
Nominal running current (RLA) Cooling
A
Maximum running current
A
Power supply
Phase/Frequency/Voltage
Hz/V



.
.



.
.





.
.
.
.
.
.
.
,
,
,
,
,
,
,
.
.
.

.
.

.
.















Stepless


,


.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
,
,



.
.


.


.
.






















.mm



MicroTech III





,


.
.
.
.
.
,
,
,
,
,
C

,


C
,
,


C
,
,


.
.
.
.
.
.
.
.
.
.
.
.
,
,
,
,
,
,
,
,
Single pass shell and tube


.
.
.
.
.










Single pass shell and tube
.
.
.
.
.
.
.
.
.









Single screw compressor






-~
~
R-a





.mm
“














~//
,
,

.


.


.

.
.











343
EWWD-J-SS
Water cooled screw chiller,
standard efficiency,
standard sound
 Compact design to allow easy indoor installation or retrofit
operations
 Daikin semi-hermetic single screw stepless compressor
 High energy efficiency both at full and part load conditions
 Chilled water temperatures down to -°C on standard unit
 Optimised for use with R-a
 MicroTech III controller with superior control logic and easy
interface
EWWD-J-SS
Heating only & Cooling only
EWWD-J-SS
Cooling capacity Nom.
kW
Heating capacity Nom.
kW
Power input
Cooling
Nom.
kW
Heating
Nom.
kW
Capacity control
Method
Minimum capacity
%
EER
ESEER
COP
IPLV
Dimensions
Unit
Height
mm
Width
mm
Depth
mm
Weight
Unit
kg
Operation weight
kg
Water heat
Type
exchanger Water volume
l
evaporator
Water flow rate Nom.
l/s
Water pressure Cooling Nom.
kPa
drop
Heating Nom.
kPa
Water heat
Type
exchanger Water flow rate Nom.
l/s
condenser
Water flow rate  Nom.
l/s
Water pressure Cooling Nom.
kPa
drop
Heating Nom.
kPa
Water pressure drop  Cooling Nom.
kPa
Compressor
Type
Quantity
Sound power level Cooling
Nom.
dBA
Sound pressure level Cooling
Nom.
dBA
°CDB
Operation range Evaporator
Cooling Min.~Max.
°CDB
Condenser
Cooling Min.~Max.
Refrigerant
Type
Charge
kg
Circuits
Quantity
Piping connections Evaporator water inlet/outlet
mm
Condenser water inlet/outlet (OD)
Unit
Maximum starting current
A
Nominal running current (RLA) Cooling
A
Maximum running current
A
Power supply
Phase/Frequency/Voltage
Hz/V




.
.



.
.
.
.
.
.
.



.
.
.
.
. .
.



.
.
.
.
.
.
,



.
.



.
.



.
.
. . .
. . .
. . .
. . .
MicroTech III
  
  
  
. . .
. . .
Stepless
 
 
 






















.
.
.
.
.
.
.
.
.
.
.
.
.
,
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. .
.
. .

,
, , , , , , , , , , , , , , , ,
, , , , , , , , , , , , , , , ,
Plate heat exchanger













.
.
.
.
. . . . . . . . . . . .






























Single pass shell and tube
.
.
. . . . .
.
. .
.
. . .
.
.
.
.
. .






















Single screw compressor






-~
~
R-a














.
“ /
“






 







         


             
~//
EWWD-H-XS
Water cooled screw chiller,
high efficiency,
standard sound




High energy efficient units: full range Eurovent Class A
Heat pump version available
Flooded type heat exchangers
MicroTech III controller with superior control logic and easy
interface
EWWD-H-XS
Heating only & Cooling only
EWWD-H-XS
Cooling capacity Nom.
kW
Heating capacity Nom.
kW
Power input
Cooling
Nom.
kW
Heating
Nom.
kW
Capacity control
Method
Minimum capacity
%
EER
ESEER
COP
IPLV
Dimensions
Unit
Height
mm
Width
mm
Depth
mm
Weight
Unit
kg
Operation weight
kg
Water heat
Type
exchanger Water volume
l
evaporator
Water flow rate Nom.
l/s
Water pressure Cooling Nom.
kPa
drop
Heating Nom.
kPa
Water heat
Type
exchanger Water flow rate Nom.
l/s
condenser
Water pressure Cooling Nom.
kPa
drop
Heating Nom.
kPa
Compressor
Type
Quantity
Sound power level Cooling
Nom.
dBA
Sound pressure level Cooling
Nom.
dBA
°CDB
Operation range Evaporator
Cooling Min.~Max.
°CDB
Condenser
Cooling Min.~Max.
Refrigerant
Type
Charge
kg
Circuits
Quantity
Piping connections Evaporator water inlet/outlet
mm
Condenser water inlet/outlet
inch
Unit
Maximum starting current
A
Nominal running current (RLA) Cooling
A
Maximum running current
A
Power supply
Phase/Frequency/Voltage
Hz/V



.
.



.
.



.
.










.
.
.
.
.
.
.
.
,
,
.
.
.
.
.
.
.
.
.
.
.
.
,
,
,
,
,
,
,
,
MicroTech III





Stepless


,


.

.



.
.


.






,
,
,
,

.

.




.


.


.
.
.
.
.
.
.
.
,
,
,
,
,
,
,
,
,
Single pass shell and tube



.
.
.






Single pass shell and tube
.
.
.






Single screw compressor

.
.
.
.
.
.
C
,
,


C
,
,


.
.
.
.
.
.
.
.
,
,
,
,
,
,

.



.

.
.


.
,
,
,
,

.


.




.














-~
~
R-a



.


C
,
,


,




,




.
















~//













345
EWLP-KBW1N
Condenserless scroll chiller
 One of the most compact units on the market:
mmxmmxmm
 Daikin scroll compressor
 Optimised for use with R-C
 Electronic DDC controller
 Low operating sound level
 Low energy consumption
 Low refrigerant volume
 Easy installation and maintenance
 Stainless steel plate heat exchanger
 Compatible with hydraulic module EHMC
 Standard integrated: main switch, pressure ports, flow switch,
filter, shut-off valves and air purge
 μC²SE controller featuring top-of-the-range performance and user
friendliness
Cooling only
EWLP-KBWN
Cooling capacity Nom.
kW
Power input
Cooling
Nom.
kW
Capacity steps number
EER
Dimensions
Unit
HeightxWidthxDepth
mm
Weight
Unit
kg
Water heat
Minimum water volume in the system
l
exchanger Type
evaporator
Water flow rate Min.
l/min
Nom.
l/min
Max.
l/min
Model
Quantity
Compressor
Type
Quantity
Sound power level Cooling
Nom.
dBA
°CDB
Operation range Evaporator
Cooling Min.~Max.
°CDB
Condenser
Cooling Min.~Max.
Refrigerant
Type
Control
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Evaporator water drain
Power supply
Phase/Frequency/Voltage
Hz/V


.
.
EWLP-KBWN

.
.

.
.



.
.
xx










.
μC²SE

.
.

.
.
.
.




Brazed plate










Hermetically sealed scroll compressor

.
.

.
xx,



.
.








.




-~
~
R-C
Thermostatic expansion valve

FBSP mm



FBSP mm
Field installation
N~//
EWLD-J-SS
Condenserless screw chiller,
standard efficiency,
standard sound
 Compact design to allow easy indoor installation or retrofit
operations
 Daikin semi-hermetic single screw stepless compressor
 High energy efficiency both at full and part load conditions
 Chilled water temperatures down to -°C on standard unit
 Optimised for use with R-a
 MicroTech III controller with superior control logic and easy
interface
EWLD-J-SS
Cooling only
Cooling capacity
Power input
Capacity control
EER
Dimensions
Weight
Nom.
Cooling
Nom.
Method
Minimum capacity
EWLD-J-SS 
kW 
kW .
Height
Width
Depth
Unit
Operation weight
Water heat
Type
exchanger Water volume
evaporator
Water flow rate Nom.
Water pressure drop Cooling Nom.
Compressor
Type
Quantity
Sound power level Cooling
Nom.
Sound pressure level Cooling
Nom.
Operation range Evaporator
Cooling Min.~Max.
Condenser
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage


.


.
.
.
.
. .
,
%
.
Unit


.
 
 
. .
.
MicroTech III


.
 
 
. .
Stepless
.
.



.
mm
mm

mm
,
kg , , , , , , , , , ,
kg , , , , , , , , , ,
Plate heat exchanger
l 









l/s .
.
.
.
. . . . . .
kPa 








Single screw compressor

dBA

dBA

°CDB
-~
°CDB
~
R-a
kg 










. mm
A


   

A 





   
A 

       
Hz/V
~//



.















.
. .
,
.
.
.
, , ,
, , ,

.


.


.

,
,
.


.

.












 









 
 
347
EWLD-G-SS
Condenserless screw chiller,
standard efficiency,
standard sound





Stepless single-screw compressor
Optimised for use with R-a
- truly independent refrigerant circuits
Standard electronic expansion valve
DX shell and tube evaporator – one pass refrigerant side for easy
oil circulation and return
 All models are PED pressure vessel approved
 Partial heat recovery available
 MicroTech III controller with superior control logic and easy
interface
EWLD-G-SS
Cooling only
Cooling capacity
Power input
Capacity control
EER
Dimensions
Weight
Nom.
Cooling
Nom.
Method
Minimum capacity
Unit
EWLD-G-SS
kW
kW
Height
Width
Depth
Unit
Operation weight
Water heat
Type
exchanger Water volume
evaporator
Water flow rate Nom.
Water pressure drop Cooling Nom.
Compressor
Type
Quantity
Sound power level Cooling
Nom.
Sound pressure level Cooling
Nom.
Operation range Evaporator
Cooling Min.~Max.
Condenser
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage



.


.
.
.
%


.


.




.

Stepless



.
.
.
,
.
.
mm
mm
mm
kg
kg
l
l/s
kPa
MicroTech III

.

.
,
,
,
Single pass shell and tube



.
.
.
.
.





Single screw compressor



dBA
dBA
°CDB
°CDB
.
,
.
.
,
,
,

.


.

.




-~
~
R-a

kg


.mm
A
A
A
Hz/V



,
,
,
,

.




.
,
,
,
,
,












.mm








~//
.mm








EWLD-I-SS
Condenserless screw chiller,
standard efficiency,
standard sound
 DX shell and tube evaporator – one pass refrigerant side for easy
oil circulation and return
 Stepless single-screw compressor
 Standard electronic expansion valve
 All models are PED pressure vessel approved
 Optimised for use with R-a
EWLD-I-SS
Cooling only
Cooling capacity
Power input
Capacity control
MicroTech III
EWLD-I-SS            C C C C C C C C
kW            , , , , , , , ,
kW . .                 
Stepless
%
.
.
.
EER
. . . . . .
.
. . . . .
.
. . .
Dimensions
Unit
Height
mm
,
,
,
Width
mm
,
,
Depth
mm
,
,
,
, , , , , , , ,
,
,
,
,
Weight
Unit
kg
,
,
,
Operation weight
kg
, , , , , , , , , ,
Water heat
Type
Single pass shell and tube
exchanger Water volume
l

      


 

 
evaporator
Water flow rate Nom.
l/s . . . . . . . . . . . . . . . . . . .
Water pressure drop Cooling Total
kPa                   
Compressor
Type
Single screw compressor
Quantity



Sound power level Cooling
Nom.
dBA 

 



Sound pressure level Cooling
Nom.
dBA  

 




°CDB
-~
Operation range Evaporator
Cooling Min.~Max.
°CDB
~
Condenser
Cooling Min.~Max.
Refrigerant
Type
R-a
Charge
kg

Circuits
Quantity



Piping connections Evaporator water inlet/outlet (OD)
mm
Unit
Maximum starting current
A 

  







Nominal running current (RLA) Cooling
A                   
Maximum running current
A                   
Power supply
Phase/Frequency/Voltage
Hz/V
~//
Nom.
Cooling
Nom.
Method
Minimum capacity
349
EWWD-FZXS
Water cooled centrifugal chiller,
high efficiency, standard sound
 Totally oil-free operation resulting in reduced maintenance costs
and increased reliability
 An inverter driven compressor allows the capacity to be adjusted
precisely to match variations in room and outside temperatures
 Onboard digital electronics provide smart controls
EWWD-FZXS
Cooling only
Cooling capacity
Power input
Capacity control
EER
ESEER
IPLV
Dimensions
Weight
Min.
Max.
Cooling
Min.
Max.
EWWD-FZXS
kW
kW
kW
kW



.
.



.

.
.
.
.
.
.
,
,
.
.
.
Method
Unit



.




.

C

,
.

.
.
.
,
,
,
,
,
.
.
.
,
,
,
,
,

.


.

.

.






Stepless
Height
Width
Depth
Unit
Operation weight
Water heat
Type
exchanger Water volume
evaporator
Water flow rate Nom.
Water pressure drop Cooling Nom.
Water heat
Type
exchanger Water flow rate Nom.
condenser
Water pressure drop Cooling Nom.
Compressor
Type
Quantity
Sound power level Cooling
Nom.
Sound pressure level Cooling
Nom.
Operation range Evaporator
Cooling Min.~Max.
Condenser
Cooling Min.~Max.
Refrigerant
Type
Charge
Circuits
Quantity
Piping connections Evaporator water inlet/outlet (OD)
Condenser water inlet/outlet (OD)
Unit
Maximum starting current
Nominal running current (RLA) Cooling
Maximum running current
Power supply
Phase/Frequency/Voltage




.
.
MicroTech II
mm
mm
mm
kg
kg
,
,
,
,
l
l/s
kPa

.


.

l/s
kPa
.

.

dBA
dBA
°CDB
°CDB





kg

,
.
.
.
,
,
,
,
,
,
,
,
Flooded shell and tube


.
.


Flooded shell and tube
.
.


Oil free centrifugal compressor




~
~
R-a





.mm
.mm
A
A
A
Hz/V
.mm
mm
.mm









~//




DWDC/DWSC
Water cooled centrifugal chiller,
high efficiency, standard sound
 Optional Variable Frequency Drive (VFD) to improve the part load
efficiency
 High efficiency flooded type shell and tube evaporator/
condensers
 Lower equipment, installation and annual operating costs than
two single compressor chillers (DWDC)
 Main components can be removed or repaired without shutting
down the unit as the chiller has two of everything (compressors,
lubrication systems, control systems and starters) (DWDC)
 Unloading to % (DWSC) or % (DWDC) of full load provides
improved stability of the chilled water temperature and less
harmful cycling of compressors
 Single stage centrifugal compressor (DWSC)
Cooling only
Cooling capacity
Compressor
Refrigerant
Min.
Max.
Type
Type
DWDC/DWSC
kW
kW
DWSC-DWDC
DWDC

,
MicroTech II
DWSC

,
Single stage centrifugal compressor
R-a
351
Fan Coil Units are a highly efficient
means of turning a water chiller,
heat pump or hot water boiler into
an efficient, quiet air conditioning
system. These units are an effective
solution to provide a comfortable
environment for both commercial and
residential applications. Daikin offers
a wide range of Fan Coil Units for both
concealed and exposed applications.
Three models are available in flexible
application. The only moving part in
the units is the fan, making them ideal
for use in offices, hotels and at home.
The goal is to obtain the right solution,
both technically and aesthetically.
352
Fan coil units
Why choose Daikin fan coil units? 354
Products overview NEW
358
Cassette units FWG-AT/AF360
FWC-BT/BF 361
FWF-BT/BF 362
FWF-CT 363
Floor standing unit
FWZ-AT/AF 364
FWV-DAT/DAF 365
Flexi type units FWR-AT/AF 366
FWL-DAT/DAF367
FWS-AT/AF 368
FWM-DAT/DAF369
Wall mounted unit FWT-CT370
Concealed ceiling units FWE-CT/CF 371
FWP-AT 372
373
FWB-BT FWD-AT/AF374
low ESP
medium ESP
medium ESP
high ESP
For more information on Options & Accessories, please
refer to page 462 of this catalogue.
353
ARGUE CARDS
Fan coil units with BLDC motor
Designed for tomorrow, available today
As more buildings undergo renovation, the need to be able to deliver high indoor air quality in a specific space
in an economic and cost-effective way without having to do a radical re-fit of the entire HVAC system has made
fan coil technology an obvious solution.
Daikin has a full capacity range of aesthetically pleasing fan coil units with advanced controls that reliably
deliver excellent comfort levels. And by using a refined range of advanced DC fan motors, we are able to offer
flexibility while maintaining very low noise levels.
Why choose Daikin
fan coil units?
r The new brushless DC ranges reflect
Daikin’s commitment to developing
highly efficient fan coil units that
help to reduce energy consumption,
without compromising on reliability
and performance.
r High level quality is written large
for us and we are pleased to offer
high technology solutions to
the market.
354
Benefits for the installer
› Reduced amount of sizes: less stock space needed
› Modular designs for multiple configurations
› Easy integration in BMS system via modbus protocol*
* except for FWG-AT/AF range
Benefits for the consultant
› Best solution in the market in order to have top efficiency,
best comfort and lowest sound levels
Benefits for the end user
› High comfort level
› Up to 70% savings on running costs
› Controller with timer programmed operating mode
Marketing tools
Download the software:
Software Downloads > Sales Software
> Fan Coil Selection
Higher efficiency than AC
(Alternative Current) motor
›
›
›
›
Low sound levels
› Lower minimum rotation speed
› No start-stop sequence
› Gradual air output
Up to 70% energy savings
No heat generation
No power losses
Higher efficiency than AC motors
to reach set point
High flexibility level
› Multiple configurations: cassettes,
floorstanding units, flexi type units with
or without cabinet and ducted units
› Wide capacity range in heating and cooling
› Different piping topologies and
connection valves
High comfort level
› Less fluctuation of air temperature
and relative humidity
› More consistent output level
› Stepless speed change for gradual air output
› More accurate adjustments to reach set point
FWG-AT/AF
FWR-AT/AF
FWC-BT/BF
FWP-AT
FWS-AT/AF
FWZ-AT/AF
355
Fan coil units
FW
W S-AT/AFF
FLEXI TYPE UN
N IT
FW
W FF-BT
BTT/B
/BF
CEI
EILIN
LING
G M OUN
OU T ED C ASS
ASSEE TT
TTEE
FWCFW
C-BT
BT/B
/B
BF
CEILIN
CEI
LING
G MOUN
M OU
OUN
UNTED
D C ASS
S S ETT
SS
TTEE
356
Fan coil units
FW
W TT-CT
CT
WAL
WA
ALLL MOUNTED
M
U T
UN
UNI
F W RFW
R-A
ATT/A
T/A
AF
FFLO
FL
LLO O R S TA
TANDI
NDI
D NG U
UNI
NT
NI
357
Fan coil units
Product overview
Type
Model
Product name
Capacity
4-way blow ceiling mounted cassette
- Brushless DC fan motor unit for ceiling mounting
- High efficiency, continuous air flow regulation and fan speed modulation
- Reduced sound emissions
- Easy installation and maintenance
FWG-AT/AF
Round flow cassette
- Brushless DC fan motor unit for ceiling mounting
- 360° air discharge ensures uniform air flow
- Integrated fresh air intake
- Easy installation in corners
- Standard drain pump with 850 mm lift
FWC-BT/BF
Cooling: 2.0 - 5.2 kW
Heating: 2.9 - 6.7 kW
4-way blow ceiling mounted cassette
- AC fan motor unit for ceiling mounting
- Integrated fresh air intake
- Horizontal auto swing
- Easy installation in corners
- Standard drain pump with 750 mm lift
FWF-BT/BF
Cooling: 2.49 - 4.54 kW
Heating: 3.52 - 5.28 kW
4-way blow ceiling mounted cassette
- AC fan motor unit for ceiling mounting
- Easy installation and maintenance
- High power air flow
- Standard drain pump with 700 mm lift
FWF-CT
Cooling: 2.64 - 10.08 kW
Heating: 2.46 - 11.18 kW
FWZ-AT/AF
Cooling: 2.64 - 10.08 kW
Heating: 2.46 - 11.18 kW
FWV-DAT/DAF
Cooling: 1.46 -8.02 kW
Heating: 1.90 - 10.03 kW
FWR-AT/AF
Cooling: 2.64 - 10.08 kW
Heating: 2.46- 11.18 kW
FWL-DAT/DAF
Cooling: 1.46 - 8.02 kW
Heating: 1.90 - 10.03 kW
FWS-AT/AF
Cooling: 2.64 - 10.08 kW
Heating: 2.46 - 11.18 kW
FWM-DAT/DAF
Cooling: 1.46 -8.02 kW
Heating: 1.90 - 10.03 kW
FWT-CT
Cooling: 2.43 - 5.28 kW
Heating: 3.22 - 7.33 kW
FWE-CT/CF
Cooling: 2.10 - 9.96 kW
Heating: 2.3 - 13.00 kW
Medium ESP ducted unit
- Brushless DC fan motor unit for horizontal concealed mounting
- Instant adjustment to temperature and relative humidity changes
- Available static pressure up to 80 Pa
- Low sound levels
FWP-AT
Cooling: 2.61 - 6.47 kW
Heating: 5.47 - 12.28 kW
Medium ESP ducted unit
- AC fan motor unit for horizontal concealed mounting
- Available static pressure up to 80 Pa
- 7-speed electrical motors (thermal protection on windings)
- Easy maintenance
FWB-BT
Cooling: 2.61 - 10.34 kW
Heating: 5.47 - 18.78 kW
FWD-AT/AF
Cooling: 3.90 - 18.30 kW
Heating: 4.05 - 21.92 kW
NEW
Cooling: 5.8~ 8.7 kW
Heating: 7.5 ~ 12.1 kW
Ceiling mounted cassette
Floor standing unit
- Brushless DC fan motor for vertical mounting
- Continuous air flow regulation and fan speed modulation
- Up to 70% energy savings
- Low sound levels
Floor standing unit
Floor standing unit
- AC fan motor unit for horizontal or vertical concealed mounting
- Insulated valve packages, no extra drain pan required
- Fast-on connections for electrical options: no tools needed
- Easy maintenance
Flexi type unit with cabinet
- Brushless DC fan motor unit for horizontal or vertical mouting
- Continuous air flow regulation and fan speed modulation
- Up to 70% energy savings
- Low sound levels
Flexi type unit with cabinet
- AC fan motor unit for horizontal or vertical concealed mounting
- Insulated valve packages, no extra drain pan required
- Fast-on connections for electrical options: no tools needed
- Easy maintenance
Flexi type unit
Flexi type unit without cabinet
- Brushless DC fan motor unit for horizontal or vertical concealed mounting
- Continuous air flow regulation and fan speed modulation
- Up to 70% energy savings
- Low sound levels
Flexi type unit without cabinet
- AC fan motor unit for horizontal or vertical concealed mounting
- Insulated valve packages, no extra drain pan required
- Fast-on connections for electrical options: no tools needed
- Easy maintenance
Wall mounted unit
Wall mounted unit
- AC fan motor unit for wall mounting
- High aesthetic cabinet design
- Optimum air distribution
- Easy installation
- 3-speed fan motor
Low ESP ducted unit
- AC fan motor unit for horizontal concealed mounting
- Available static pressure up to 50 Pa
- Easy installation and maintenance
- 4-speed fan motor
- High power air flow
Concealed ceiling unit
High ESP ducted unit
- AC fan motor unit for horizontal or vertical concealed mounting
- Available static pressure up to 120 Pa
- Easy maintenance
358
Capacity class (kW)
1
2
3
4
5
6
7
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
10
y
11
12
~
18
y
y
y
y
y
y
y
y
y
9
y
y
y
8
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
359
FWG-AT/AF
4-way blow ceiling mounted
cassette
BLDC fan motor unit for ceiling mounting. High efficiency,
continuous air flow regulation and fan speed modulation
 Up to % energy savings with brushless DC motor technology
compared to traditional technology
 Instant adjustment to temperature and relative humidity changes
 Continuous modulation of fan speed resulting in reduced sound
emissions, in comparison with fixed speed AC motor fan coil
units
 Easy installation and maintenance
FWG-AT/AF
BRCA
FWG-AT/AF
Cooling capacity
Total capacity
Sensible
capacity
Heating capacity
2-Pipe
4-Pipe
Dimensions
Weight
Heat exchanger
Water pressure
drop
Fan
Unit
Unit
Water volume
Cooling
Heating
Type
Air flow rate
High
Medium
Low
Quiet
High
Medium
Low
Quiet
High
Low
Quiet
High
Low
Quiet
Height
Width
Depth
High
High
High
Low
Sound power level High
Quiet
Sound pressure level High
Piping connections Drain
OD
Power supply
Phase/Frequency/Voltage
Control systems
Infrared remote control
Wired remote control

05
08
2-pipe
8.80
7.25
5.80
4.55
6.43
5.41
4.26
3.22
11.20
7.00
5.40
-
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
mm
mm
mm
kg
l
kPa
kPa
5.90
4.65
3.50
2.40
4.51
3.44
2.54
1.71
7.10
4.45
3.30
26
1.36
24
21
28
1.97
20
18
m³/h
m³/h
dBA
dBA
dBA
mm
Hz/V
1,053
595
46
30
37
1,512
951
57
40
47
265
11
05
11.75
9.70
7.85
6.15
8.37
6.97
5.54
4.27
13.70
9.25
7.05
4.40
3.60
2.80
2.00
3.85
2.99
2.24
1.56
08
4-pipe
7.20
6.10
5.00
3.90
5.75
4.85
3.81
2.91
11.20
8.00
6.40
7.65
5.05
3.75
300
265
11
9.00
7.75
6.50
5.20
7.17
6.06
4.90
3.89
15.65
11.45
9.35
300
820
820
32
26
2.35
1.36
41
18
37
22
Direct drive turbo fan
1,801
1,053
1,155
595
59
46
43
30
51
37
19.05
1~/50/220-240
included with decoration panel
BRC51A61
28
1.97
19
32
32
2.35
32
52
1,512
951
57
40
47
1,801
1,155
59
43
51
FWC-BT/BF
Round flow cassette
BLDC fan motor unit for ceiling mounting. ° air
discharge
 ° air discharge ensures uniform air flow and temperature
distribution
 Modern style decoration panel in white (RAL)
 Fresh air intake integrated in the same system thus reducing
installation cost as no additional ventilation is required
 Comfortable horizontal air discharge ensures draughtfree
operation and prevents ceiling soiling
 Possibility to shut  or  flaps for easy installation in corners
FWC-BT/BF
BRCD
BRCEF/F
 Standard drain pump with mm lift increases flexibility and
installation speed
FWC-BT/BF
06
07
08
09
06
07
2-pipe
Cooling capacity
Total capacity
Sensible
capacity
Heating capacity
2-Pipe
4-Pipe
Power input
Dimensions
Weight
Fan
Super high
High
Low
Unit
Unit
Type
Quantity
Air flow rate
Super high
High
Low
Super high
High
Low
Super high
High
Low
Super high
High
Low
Height
Width
Depth
High
Low
Sound power level Super high
High
Sound pressure
Super high
level
High
Piping connections Drain
OD
Power supply
Phase/Frequency/Voltage
Control systems
Infrared remote control
Wired remote control
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
W
W
W
mm
mm
mm
kg
m³/h
m³/h
dBA
dBA
dBA
dBA
mm
Hz/V
5.8
5.0
4.1
4.1
3.4
2.8
8.0
6.3
5.5
6.8
5.6
4.7
4.7
4.0
3.3
8.9
7.1
5.9
7.7
6.3
4.9
5.6
4.5
3.5
10.6
8.3
6.9
8.7
7.2
5.7
6.5
5.3
4.1
12.1
9.5
7.8
5.8
4.9
4.0
4.1
3.4
2.7
54
46
37
09
77
58
39
6.6
5.6
4.6
4.7
3.9
3.2
7.6
6.3
4.8
5.6
4.4
3.4
8.7
7.2
5.7
6.5
5.2
4.0
9.7
7.8
6.7
77
59
40
11.0
8.8
7.8
107
77
46
1,476
852
53
44
39
32
1,746
1,014
57
49
43
37
-
45
40
34
08
4-pipe
7.5
6.2
5.5
46
41
35
107
76
45
8.4
6.8
5.9
55
47
38
288
840
840
26
1,062
720
43
36
29
24
1,236
840
47
39
33
28
29
Turbo fan
1
1,518
1,776
1,032
1,200
888
1,044
684
804
53
57
43
47
44
49
36
39
39
43
29
33
32
37
24
28
VP25 (External dia.32 / internal dia. 25)
1~/50/220-240
BRC7E532F / BRC7E533F
BRC315D7
361
FWF-BT/BF
4-way blow ceiling mounted
cassette
AC fan motor unit for ceiling mounting. Possibility to shut
 or  flaps
 Modern style decoration panel in white (RAL)
 Compact casing enables unit to fit flush into ceilings and match
standard architectural modules
 Comfortable horizontal auto swing ensures draughtfree
operation and prevents ceiling soiling
 Fresh air intake integrated in the same system thus reducing
installation cost as no additional ventilation is required
 Standard drain pump with 750mm lift
FWF-BT/BF
BRCD
FWF-BT/BF
02
03
04
BRCE/
05
02
03
2-pipe
Cooling capacity
Total capacity
Sensible
capacity
Heating capacity
2-Pipe
4-Pipe
Power input
Dimensions
Weight
Fan
Super high
High
Low
Unit
Unit
Type
Quantity
Air flow rate
Super high
High
Low
Super high
High
Low
Super high
High
Low
Super high
High
Low
Height
Width
Depth
High
Low
Sound power level Super high
High
Sound pressure
Super high
level
High
Piping connections Drain
OD
Power supply
Phase/Frequency/Voltage
Control systems
Infrared remote control
Wired remote control

kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
W
W
W
mm
mm
mm
kg
m³/h
m³/h
dBA
dBA
dBA
dBA
mm
Hz/V
2.0
1.7
1.5
1.5
1.3
1.1
2.9
2.6
2.3
3.2
2.8
4.2
3.3
2.5
2.0
1.7
2.8
2.1
1.4
4.0
3.4
5.4
4.1
2.8
-
74
67
60
04
05
3.5
2.8
4.5
3.5
2.6
3.3
2.3
1.5
4-pipe
5.2
4.0
2.9
3.5
2.7
1.8
6.7
5.3
3.6
2.0
1.7
1.4
1.5
2.7
2.3
1.8
1.7
1.1
1.0
-
3.9
3.1
2.3
90
70
55
2.4
1.7
1.3
118
89
62
3.8
3.3
4.9
3.9
2.8
74
67
60
94
74
62
55
6.1
4.8
3.5
121
93
66
285
575
575
19
468
318
44
40
31
27
Turbo fan
1
660
876
468
438
420
318
50
55
44
46
44
49
40
42
40
45
31
33
33
39
27
29
VP20 (External dia.26 / Internal dia. 20)
1~/50/220-440
BRC7E530 / BRC7E531
BRC315D7
20
618
300
52
46
42
35
822
390
57
51
47
41
FWF-CT
4-way blow ceiling mounted
cassette
AC fan motor unit for ceiling mounting
  way air discharge and air swing
 Compact casing enables unit to fit flush into ceilings and match
standard architectural modules
 Air suction from underneath
 Easy installation and maintenance
 Built-in high pressure drain pump with 700mm lift
 Double-intake centrifugal fans
 High power air flow
 -speed fan motor
FWF-CT
BRCA/A
FWF-CT
Cooling capacity
Total capacity
Heating capacity
Sensible
capacity
2-Pipe
Power input
Dimensions
Weight
High
Low
Unit
High
Low
High
Low
High
Low
Height
Width
Depth
Unit
Operation weight
Fan
Type
Quantity
Air flow rate
High
Low
Sound power level High
Sound pressure level High
Piping connections Drain
OD
Water connections Std. heat exchanger
Power supply
Phase/Frequency/Voltage
Current input
High
Medium
Low
Control systems
Infrared remote control
Wired remote control
kW
kW
kW
kW
kW
kW
W
W
mm
mm
mm
kg
kg
m³/h
m³/h
dBA
dBA
mm
inch
Hz/V
A
A
A
02
2.49
1.91
1.91
1.49
3.52
2.64
63
45
03
2-pipe
4.10
2.78
2.93
1.88
4.69
3.08
64
52
250
570
570
22
22
646
391
52
42
0.27
0.22
0.19
04
4.54
3.37
3.37
2.43
5.28
3.81
79
69
23
23
Direct drive turbo fan
1
680
374
54
45
19.05
3/4
1~/50/220-440
0.28
0.25
0.22
included with decoration panel
MERCA / SRC-HPA
748
476
56
48
0.34
0.31
0.35
363
FWZ-AT/AF
Floor standing unit
BLDC fan motor unit for vertical mounting. Continuous air
flow regulation and fan speed modulation
 Up to % energy savings with brushless DC motor technology
compared to traditional technology
 Instant adjustment to temperature and relative humidity
changes
 Low operating sound level
 Highly flexible solutions: multiple sizes, piping topologies and
connection valves
 Requires very little installation space
FWZ-AT/AF
FWECA
FWZ-AT/AF
02
03
06
08
02
03
2-pipe
Cooling capacity
Total capacity
Heating capacity
Sensible
capacity
2-Pipe
4-Pipe
Power input
Dimensions
Weight
Heat exchanger
Additional heat exchanger
Water flow
Fan
Min.
Max.
Unit
Unit
Water volume
Water volume
Cooling
Heating
Type
Quantity
Air flow rate
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Height
Width
Depth
Max.
Min.
Sound power level Max.
Piping connections Drain
OD
Power supply
Phase/Frequency/Voltage
Current input
Max.
Min.
Control systems
Wired remote control

kW
kW
kW
kW
kW
kW
kW
kW
W
W
mm
mm
mm
kg
l
l
l/h
l/h
m³/h
m³/h
dBA
mm
Hz/V
A
A
0.61
2.64
0.41
1.95
0.69
3.47
0.88
4.96
0.58
3.60
0.95
6.40
1.19
6.32
0.79
4.80
1.29
7.51
1.79
10.08
1.20
7.43
1.92
11.18
0.60
2.64
0.40
1.95
2.2
0.88
4.96
0.58
3.60
0.82
2.46
3.4
101.4
82.7
08
1.19
6.32
0.79
4.80
1.79
10.08
1.20
7.43
1.76
6.45
3.24
101.4
2.83
10.06
4.2
147
1,194
33
1.4
0.4
1,084
565
1,404
251
44
2.1
0.6
1,728
882
2
1,200
130
64
1,660
200
71
0.88
0.07
1.27
0.09
-
57.4
06
4-pipe
4.2
147
1.18
4.19
2.2
57.4
82.7
564
774
20
0.7
987
226
25
1
454
454
853
853
1
560
70
62
900
95
70
1,194
-
0.50
0.72
0.05
1,404
251
41
2.1
774
987
226
31
21
26
1.4
0.7
1
0.2
0.3
1,084
1,728
454
853
1,084
1,728
216
367
Centrifugal multi-blade, double suction
2
1
1,200
1,660
560
900
130
200
70
95
64
71
62
70
16
1~/50/230
0.88
1.27
0.50
0.72
0.07
0.09
0.05
FWEC3A
FWV-DAT/DAF
Floor standing unit
AC fan motor unit for vertical mounting








Pre-assembled 3-way/4-port on/off valves are available
High efficiency heat exchanger
Valve packages are insulated, no extra drain pan required
Valve packages contain balancing valves and sensor pocket
Fast-on connections for electrical options: no tools needed
Washable air filter, easily removable for maintenance
Electric heater: no relay up to kW capacity
Electric heater: equipped with two overheat cut-out thermostats
FWV-DAT/DAF
FWEC,,A / ECFWMB
FWV-DAT/DAF 01
Cooling capacity
Total capacity
Heating capacity
Sensible
capacity
2-Pipe
4-Pipe
Power input
Dimensions
Weight
Heat exchanger
Additional heat exchanger
Water flow
Fan
High
Low
Unit
Unit
Water volume
Water volume
Cooling
Heating
Type
Quantity
Air flow rate
High
Low
High
Low
High
Low
High
Low
Height
Width
Depth
High
Low
Sound power level High
Piping connections Drain
OD
Power supply
Phase/Frequency/Voltage
Current input
High
Medium
Low
Control systems
Wired remote control
kW
kW
kW
kW
kW
kW
kW
kW
W
W
mm
mm
mm
kg
l
l
l/h
l/h
m³/h
m³/h
dBA
mm
Hz/V
A
A
A
04
06
08
10
4.26
2.48
3.09
1.78
4.67
3.11
3.57
2.28
6.64
3.93
4.85
2.82
7.88
4.07
5.85
3.02
1.90 2.02 2.01
5.05 5.30
1.50
1.56
3.60 4.04
37
53
98
182 244 37
53
98
21 25 24
38 47 86 109 21 25 24
38 47
564
774
987
1,194
1,404
774
987
1,194
226
251
226
19
20
25
30
31
41
20
21
26
32
33
0.5
0.7
1
1.4
2.1
0.5
0.7
1
1.4
0.2
0.3
0.4
264 298 337 415 504 602 743 818 1,152 1,376 250 291 176 409 494 594 730 803
264 298 337 415 504 602 743 818 1,152 1,376 167 177 182 257 270 421 443 465
Centrifugal multi-blade, double suction
1
2
1
2
319
344
442
640 706 785 1,011 1,393 307 330 327 432 431 628 690 763
178
211
241
320 361 470 570 642 174
205
238
316 356 460
47 49 50
48
52 53 56 61 67 45 49 50 48 47 51 56 59
16
1~/50/230
0.44
0.43
0.17
0.24
0.26 0.25
0.44
0.43 0.82 1.10 0.17
0.24
0.26 0.25
0.13
0.16
0.21 0.20
0.29
0.31 0.57 0.76 0.13
0.16
0.21 0.20
0.29
0.31
0.10 0.12 0.11
0.14
0.19
0.22 0.39 0.50 0.10 0.12 0.11
0.14
0.19
0.22
FWEC1A / FWEC2A / FWEC3A / ECFWM
7.91
5.69
182
86
8.35
5.50
244
109
1.54
1.04
1.20
0.79
2.14
1.43
15
02
1.74
1.26
1.30
0.95
2.20
1.71
1.96
1.36
1.42
1.00
2.57
1.79
25
03 35
2-pipe
2.42 2.93 3.51
1.60 1.76 1.98
1.88 2.11 2.72
1.18 1.26 1.45
3.20 3.81 4.78
2.07 2.28 2.81
57 56
29
37
04
06
08
10
01
15
02
4.33
2.51
3.15
1.80
5.10
2.98
4.77
3.17
3.65
2.32
5.95
3.96
6.71
3.97
4.91
2.84
7.83
4.77
8.02
4.11
5.96
3.05
10.03
5.24
1.46
0.99
1.14
0.75
1.69
1.24
1.27
0.93
1.79
1.26
1.46
0.98
25
03 35
4-pipe
2.38 2.87 3.46
1.58 1.73 1.96
1.85 2.07 2.71
1.17 1.24 1.44
2.92 3.08 4.80
2.06 2.18 3.21
57 56
29
37
1,404
251
44
2.1
0.6
1,138 1,362
694 733
998 1,362
565 636
60 66
0.82 1.10
0.57 0.76
0.39 0.50
365
FWR-AT/AF
Flexi type unit with cabinet
BLDC fan motor unit for horizontal or vertical mounting.
Continuous air flow regulation and fan speed modulation
 Up to % energy savings with brushless DC motor technology
compared to traditional technology
 Instant adjustment to temperature and relative humidity
changes
 Low operating sound level
 Highly flexible solutions: multiple sizes, piping topologies and
connection valves
 Requires very little installation space
FWR-AT/AF
FWECA
FWR-AT/AF
02
03
06
08
02
03
2-pipe
Cooling capacity
Total capacity
Heating capacity
Sensible
capacity
2-Pipe
4-Pipe
Power input
Dimensions
Weight
Heat exchanger
Additional heat exchanger
Water flow
Fan
Min.
Max.
Unit
Unit
Water volume
Water volume
Cooling
Heating
Type
Quantity
Air flow rate
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Height
Width
Depth
Max.
Min.
Sound power level Max.
Power supply
Phase/Frequency/Voltage
Current input
Max.
Min.
Control systems
Wired remote control

kW
kW
kW
kW
kW
kW
kW
kW
W
W
mm
mm
mm
kg
l
l
l/h
l/h
m³/h
m³/h
dBA
Hz/V
A
A
0.61
2.64
0.41
1.95
0.69
3.47
0.88
4.96
0.58
3.60
0.95
6.40
1.19
6.32
0.79
4.80
1.29
7.51
1.79
10.08
1.20
7.43
1.92
11.18
0.60
2.64
0.40
1.95
2.2
0.88
4.96
0.58
3.60
0.82
2.46
3.4
101.4
82.7
08
1.19
6.32
0.79
4.80
1.79
10.08
1.20
7.43
1.76
6.45
3.24
101.4
2.83
10.06
4.2
147
1,194
35
1.4
0.4
1,084
565
1,404
251
46
2.1
0.6
1,728
882
2
1,200
130
64
1,660
200
71
0.88
0.07
1.27
0.09
-
57.4
06
4-pipe
4.2
147
1.18
4.19
2.2
57.4
82.7
564
774
21
0.7
987
226
27
1
454
454
853
853
1
560
70
62
900
95
70
1,194
-
0.50
0.72
0.05
1,404
251
44
2.1
774
987
226
33
22
28
1.4
0.7
1
0.2
0.3
1,084
1,728
454
853
1,084
1,728
216
367
Centrifugal multi-blade, double suction
2
1
1,200
1,660
560
900
130
200
70
95
64
71
62
70
1~/50/230
0.88
1.27
0.50
0.72
0.07
0.09
0.05
FWEC3A
FWL-DAT/DAF
Flexi type unit with cabinet
AC fan motor unit for horizontal or vertical mounting








Pre-assembled 3-way/4-port on/off valves are available
High efficiency heat exchanger
Valve packages are insulated, no extra drain pan required
Valve packages contain balancing valves and sensor pocket
Fast-on connections for electrical options: no tools needed
Washable air filter, easily removable for maintenance
Electric heater: no relay up to kW capacity
Electric heater: equipped with two overheat cut-out thermostats
FWL-DAT/DAF
FWEC,,A / ECFWMB
FWL-DAT/DAF 01
Cooling capacity
Total capacity
Heating capacity
Sensible
capacity
2-Pipe
4-Pipe
Power input
Dimensions
Weight
Heat exchanger
Additional heat exchanger
Water flow
Fan
High
Low
Unit
Unit
Water volume
Water volume
Cooling
Heating
Type
Quantity
Air flow rate
High
Low
High
Low
High
Low
High
Low
Height
Width
Depth
High
Low
Sound power level High
Power supply
Phase/Frequency/Voltage
Current input
High
Medium
Low
Control systems
Wired remote control
kW
kW
kW
kW
kW
kW
kW
kW
W
W
mm
mm
mm
kg
l
l
l/h
l/h
m³/h
m³/h
dBA
Hz/V
A
A
A
04
06
08
10
4.26
2.48
3.09
1.78
4.67
3.11
3.57
2.28
6.64
3.93
4.85
2.82
7.88
4.07
5.85
3.02
1.90 2.02 2.01
5.05 5.30
1.50
1.56
3.60 4.04
37
53
98
182 244 37
53
98
21 25 24
38 47 86 109 21 25 24
38 47
564
774
987
1,194
1,404
774
987
1,194
226
251
226
20
21
27
32
33
44
21
22
28
24 34 35
0.5
0.7
1
1.4
2.1
0.5
0.7
1
1.4
0.2
0.3
0.4
264 298 337 415 504 602 743 818 1,152 1,376 250 291 176 409 494 594 730 803
264 298 337 415 504 602 743 818 1,152 1,376 167 177 182 257 270 421 443 465
Centrifugal multi-blade, double suction
1
2
1
2
319
344
442
640 706 785 1,011 1,393 307 330 327 432 431 628 690 763
178
211
241
320 361 470 570 642 174
205
238
316 356 460
47 49 50
48
52 53 56 61 67 45 49 50 48 47 51 56 59
1~/50/230
0.17
0.24
0.26 0.25
0.44
0.43 0.82 1.10 0.17
0.24
0.26 0.25
0.44
0.43
0.13
0.16
0.21 0.20
0.29
0.31 0.57 0.76 0.13
0.16
0.21 0.20
0.29
0.31
0.10 0.12 0.11
0.14
0.19
0.22 0.39 0.50 0.10 0.12 0.11
0.14
0.19
0.22
FWEC1A / FWEC2A / FWEC3A / ECFWMB6
7.91
5.69
182
86
8.35
5.50
244
109
1.54
1.04
1.20
0.79
2.14
1.43
15
02
1.74
1.26
1.30
0.95
2.20
1.71
1.96
1.36
1.42
1.00
2.57
1.79
25
03 35
2-pipe
2.42 2.93 3.51
1.60 1.76 1.98
1.88 2.11 2.72
1.18 1.26 1.45
3.20 3.81 4.78
2.07 2.28 2.81
57 56
29
37
04
06
08
10
01
15
02
4.33
2.51
3.15
1.80
5.10
2.98
4.77
3.17
3.65
2.32
5.95
3.96
6.71
3.97
4.91
2.84
7.83
4.77
8.02
4.11
5.96
3.05
10.03
5.24
1.46
0.99
1.14
0.75
1.69
1.24
1.27
0.93
1.79
1.26
1.46
0.98
25
03 35
4-pipe
2.38 2.87 3.46
1.58 1.73 1.96
1.85 2.07 2.71
1.17 1.24 1.44
2.92 3.08 4.80
2.06 2.18 3.21
57 56
29
37
1,404
251
46
2.1
0.6
1,138 1,362
694 733
998 1,362
565 636
60 66
0.82 1.10
0.57 0.76
0.39 0.50
367
FWS-AT/AF
Flexi type unit without cabinet
BLDC fan motor unit for horizontal or vertical concealed
mounting. Continuous air flow regulation and fan speed
modulation
 Blends unobtrusively with any interior décor: only the suction
and discharge grilles are visible
 Up to % energy savings with brushless DC motor technology
compared to traditional technology
 Instant adjustment to temperature and relative humidity
changes
 Low operating sound level
 Highly flexible solutions: multiple sizes, piping topologies and
connection valves
FWS-AT/AF
FWECA
FWS-AT/AF
02
03
06
08
02
03
2-pipe
Cooling capacity
Total capacity
Heating capacity
Sensible
capacity
2-Pipe
4-Pipe
Power input
Dimensions
Weight
Heat exchanger
Additional heat exchanger
Water flow
Fan
Min.
Max.
Unit
Unit
Water volume
Water volume
Cooling
Heating
Type
Quantity
Air flow rate
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Height
Width
Depth
Max.
Min.
Sound power level Max.
Piping connections Drain
OD
Power supply
Phase/Frequency/Voltage
Current input
Max.
Min.
Control systems
Wired remote control

kW
kW
kW
kW
kW
kW
kW
kW
W
W
mm
mm
mm
kg
l
l
l/h
l/h
m³/h
m³/h
dBA
mm
Hz/V
A
A
0.61
2.64
0.41
1.95
0.69
3.47
0.88
4.96
0.58
3.60
0.95
6.40
1.19
6.32
0.79
4.80
1.29
7.51
1.79
10.08
1.20
7.43
1.92
11.18
0.60
2.64
0.40
1.95
2.2
0.88
4.96
0.58
3.60
0.82
2.46
3.4
101.4
82.7
08
1.19
6.32
0.79
4.80
1.79
10.08
1.20
7.43
1.76
6.45
3.24
101.4
2.83
10.06
4.2
147
1,004
25
1.4
0.4
1,084
565
1,214
249
34
2.1
0.6
1,728
882
2
1,200
130
64
1,660
200
71
0.88
0.07
1.27
0.09
-
57.4
06
4-pipe
4.2
147
1.18
4.19
2.2
57.4
82.7
535
584
15
0.7
794
224
19
1
454
454
853
853
1
560
70
62
900
95
70
1,004
-
0.50
0.72
0.05
1,214
249
32
2.1
584
794
224
23
16
20
1.4
0.7
1
0.2
0.3
1,084
1,728
454
853
1,084
1,728
216
367
Centrifugal multi-blade, double suction
2
1
1,200
1,660
560
900
130
200
70
95
64
71
62
70
17
1~/50/230
0.88
1.27
0.50
0.72
0.07
0.09
0.05
FWEC3A
FWM-DAT/DAF
Flexi type unit without cabinet
AC fan motor unit for horizontal or vertical concealed
mounting








Pre-assembled 3-way/4-port on/off valves are available
High efficiency heat exchanger
Valve packages are insulated, no extra drain pan required
Valve packages contain balancing valves and sensor pocket
Fast-on connections for electrical options: no tools needed
Washable air filter, easily removable for maintenance
Electric heater: no relay up to kW capacity
Electric heater: equipped with two overheat cut-out thermostats
FWM-DAT/DAF
FWEC,,A
FWM-DAT/DAF 01
Cooling capacity
Total capacity
Heating capacity
Sensible
capacity
2-Pipe
4-Pipe
Power input
Dimensions
Weight
Heat exchanger
Additional heat exchanger
Water flow
Fan
High
Low
Unit
Unit
Water volume
Water volume
Cooling
Heating
Type
Quantity
Air flow rate
High
Low
High
Low
High
Low
High
Low
Height
Width
Depth
High
Low
Sound power level High
Piping connections Drain
OD
Power supply
Phase/Frequency/Voltage
Current input
High
Medium
Low
Control systems
Wired remote control
kW
kW
kW
kW
kW
kW
kW
kW
W
W
mm
mm
mm
kg
l
l
l/h
l/h
m³/h
m³/h
dBA
mm
Hz/V
A
A
A
04
06
08
10
4.26
2.48
3.09
1.78
4.67
3.11
3.57
2.28
6.64
3.93
4.85
2.82
7.88
4.07
5.85
3.02
1.90 2.02 2.01
5.05 5.30
1.50
1.56
3.60 4.04
37
53
98
182 244 37
53
98
21 25 24
38 47 86 109 21 25 24
38 47
535
584
794
1,004
1,214
584
794
1,004
224
249
224
14
15
19
23
32
15
16
20
25
0.5
0.7
1
1.4
2.1
0.5
0.7
1
1.4
0.2
0.3
0.4
264 298 337 415 504 602 743 818 1,152 1,376 250 291 176 409 494 594 730 803
264 298 337 415 504 602 743 818 1,152 1,376 167 177 182 257 270 421 443 465
Centrifugal multi-blade, double suction
1
2
1
2
319
344
442
640 706 785 1,011 1,393 307 330 327 432 431 628 690 763
178
211
241
320 361 470 570 642 174
205
238
316 356 460
47 49 50
48
52 53 56 61 67 45 49 50 48 47 51 56 59
17
1~/50/230
0.43
0.17
0.24
0.26 0.25
0.44
0.43 0.82 1.10 0.17
0.24
0.26 0.25
0.44
0.13
0.16
0.21 0.20
0.29
0.31 0.57 0.76 0.13
0.16
0.21 0.20
0.29
0.31
0.10 0.12 0.11
0.14
0.19
0.22 0.39 0.50 0.10 0.12 0.11
0.14
0.19
0.22
FWEC1A / FWEC2A / FWEC3A
7.91
5.69
182
86
8.35
5.50
244
109
1.54
1.04
1.20
0.79
2.14
1.43
15
02
1.74
1.26
1.30
0.95
2.20
1.71
1.96
1.36
1.42
1.00
2.57
1.79
25
03 35
2-pipe
2.42 2.93 3.51
1.60 1.76 1.98
1.88 2.11 2.72
1.18 1.26 1.45
3.20 3.81 4.78
2.07 2.28 2.81
57 56
29
37
04
06
08
10
01
15
02
4.33
2.51
3.15
1.80
5.10
2.98
4.77
3.17
3.65
2.32
5.95
3.96
6.71
3.97
4.91
2.84
7.83
4.77
8.02
4.11
5.96
3.05
10.03
5.24
1.46
0.99
1.14
0.75
1.69
1.24
1.27
0.93
1.79
1.26
1.46
0.98
25
03 35
4-pipe
2.38 2.87 3.46
1.58 1.73 1.96
1.85 2.07 2.71
1.17 1.24 1.44
2.92 3.08 4.80
2.06 2.18 3.21
57 56
29
37
1,214
249
34
2.1
0.6
1,138 1,362
694 733
998 1,362
565 636
60 66
0.82 1.10
0.57 0.76
0.39 0.50
369
FWT-CT
Wall mounted unit
AC fan motor unit for wall mounting







High aesthetic cabinet design
Optimum air distribution
Easy to install
-speed fan motor
Low operating sound level thanks to tangential fan
Insulated with self-extinguishing class  heat insulation
Removable washable air filter (self-extinguishing class )
FWT-CT
MERCA / SRC-HPA
FWT-CT
Cooling capacity
Total capacity
Heating capacity
Sensible
capacity
2-Pipe
Power input
Dimensions
Weight
High
Low
Unit
High
Low
High
Low
High
Low
Height
Width
Depth
Unit
Operation weight
Heat exchanger
Water volume
Water flow
Cooling
Heating
Fan
Type
Quantity
Air flow rate
High
Low
Sound power level High
Sound pressure level High
Piping connections Drain
OD
Water connections Std. heat exchanger
Power supply
Phase/Frequency/Voltage
Current input
High
Medium
Low
Control systems
Infrared remote control
Wired remote control

02
03
kW
kW
kW
kW
kW
kW
W
W
mm
mm
mm
kg
kg
l
l/h
l/h
2.43
2.11
1.85
1.49
3.22
2.49
31
25
2.70
2.23
2.02
1.61
3.52
2.70
32
29
288
800
206
9
9.5
0.52
420
420
460
460
m³/h
m³/h
dBA
dBA
mm
inch
Hz/V
A
A
A
442
340
45
34
476
374
48
35
0.19
0.18
0.17
WRC-HPC
04
2-pipe
3.31
2.78
2.64
2.05
4.40
3.37
42
33
05
06
4.54
3.81
3.43
2.81
6.01
4.84
53
42
5.28
4.40
4.10
3.28
7.33
5.86
72
60
310
1,065
224
14
15
0.95
9.6
0.58
570
570
Cross flow fan
1
629
442
780
780
910
910
866
663
1,053
782
59
46
0.29
0.26
0.25
0.34
0.32
0.31
55
42
19
1/2
/-/0.21
0.20
0.20
0.19
WRC-HPC
MERCA / SRC-HPA
FWE-CT/CF
Low ESP ducted unit
AC fan motor unit for horizontal concealed mounting











Easy installation and maintenance
4-speed fan motor
High power air flow
Wired electronic controllers range
Available static pressure up to Pa
Wide operating range
Standard left and right side water connection
Extended drain pan as standard
Factory mounted valve (both left and right side)
Nylon filter G class
Polyethylene insulation
FWE-CT/CF
FWEC,,A
FWE-CT/CF
Cooling capacity
Total capacity
Sensible
capacity
Heating capacity
2-Pipe
4-Pipe
Power input
Dimensions
Weight
Super high
High
Low
Unit
Super high
High
Low
Super high
High
Low
Super high
High
Low
Super high
High
Low
Height
Width
Depth
Unit
Operation weight
Heat exchanger
Water volume
Additional heat exchanger Water volume
Water flow
Cooling
Heating
Additional heat exchanger
Water pressure drop Additional heat exchanger
Fan
Type
Quantity
Air flow rate
Super high
High
Low
Sound power level Super high
High
Sound pressure
Super high
level
High
Piping connections Drain
OD
Water connections Std. heat exchanger
Add. heat exchanger
Power supply
Phase/Frequency/Voltage
Current input
Super high
High
Medium
Low
Control systems
Wired remote control
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
W
W
W
mm
mm
mm
kg
kg
l
l
l/h
l/h
l/h
kPa
02
03
04
2.17
1.81
0.90
1.61
1.33
0.70
2.79
2.31
1.20
3.22
2.78
1.40
2.44
2.08
1.20
4.28
3.67
2.00
4.34
3.49
1.80
3.27
2.58
1.40
5.61
4.44
2.30
46
39
29
69
54
40
83
59
42
06
2-pipe
6.06
5.32
2.80
4.55
3.94
2.10
7.66
6.65
3.40
119
93
60
07
08
10
02
03
04
6.83
5.68
3.10
4.83
4.30
2.50
9.26
7.62
4.40
7.84
6.92
3.90
6.02
5.25
3.10
10.50
9.18
5.30
9.96
8.64
4.90
7.58
6.48
3.70
13.00
11.10
6.30
2.10
1.76
0.85
1.55
1.28
0.66
3.16
2.69
1.40
2.37
1.99
1.18
3.98
3.22
1.63
3.19
2.53
1.35
2.3
1.94
1.02
46
39
29
3.53
3.06
1.72
69
54
40
4.56
3.76
2.03
83
59
42
163
128
89
181
145
102
230
180
121
06
4-pipe
6.05
5.20
2.72
4.49
3.81
2.02
6.17
5.37
2.88
119
93
60
07
08
10
6.78
5.61
3.10
5.16
4.20
2.47
7.79
6.79
3.88
5.91
5.09
3.05
9.91
8.61
4.88
7.45
6.39
3.65
7.6
6.42
3.92
163
128
89
8.52
7.52
4.59
181
145
102
10.4
9.16
5.42
230
180
121
253
590
705
875 1,005 1,205 1,455 1,555 1,815 705
875 1,005 1,205 1,455 1,555
17
20
24
28
37
39
46
18
22
25
30
40
41
17
20
24
28
37
39
46
18
22
25
30
40
41
0.74
1.02
1.24
1.56
1.97
2.14
2.56 0.74
1.02
1.24
1.56
1.97
2.14
0.25 0.34 0.41
0.52 0.66 0.71
360
540
756 1,044 1,188 1,368 1,728 360
540
720 1,044 1,188 1,332
252
360
504
684
828
936 1,188
108
180
216
324
432
468
3.6
8.8
15.6
31.8
58.6 74.6
Centrifugal (Blade: Forward - curve)
1
2
3
4
1
2
3
m³/h 430
638
910
1,195 1,559 1,753 2,177 416.13 626.11 834.52 1,193.03 1,547.59 1,741.82
m³/h 311
518
619
926 1,188 1,413 1,735 302.41 501.23 571.11 905.11 1,173.36 1,386.46
m³/h 150
256
284
426
569
688
808
142
256 257.48 414.34 569 684.16
dBA
51
61
58
62
64
65
51
61
58
62
64
dBA 49
56
48
55
57
58
60
49
56
48
55
57
58
dBA 41
51
48
52
54
55
41
51
48
52
54
dBA 39
46
38
45
47
48
49
39
46
38
45
47
48
mm
19.05
inch
3/4
inch
3/4
Hz/V
1~/50/220-240
A 0.206 0.309 0.372 0.533 0.731 0.811 1.031 0.206 0.309 0.372 0.533 0.731 0.811
A 0.174 0.243 0.265 0.430 0.575 0.648 0.780 0.174 0.243 0.265 0.430 0.575 0.648
A 0.150 0.208 0.217 0.325 0.472 0.523 0.648 0.150 0.208 0.217 0.325 0.472 0.523
A 0.128 0.177 0.188 0.271 0.400 0.456 0.540 0.128 0.177 0.188 0.271 0.400 0.456
FWEC1A / FWEC2A / FWEC3A
1,815
49
49
2.56
0.85
1,728
576
123
4
2,166.07
1,728.98
804.37
65
60
55
49
1.031
0.780
0.648
0.540
371
FWP-AT
Medium ESP ducted unit
BLDC fan motor unit for horizontal concealed mounting.
Continuous air flow regulation and fan speed modulation
 Blends unobtrusively with any interior décor: only the suction
and discharge grills are visible
 Up to % energy savings with brushless DC motor technology
compared to traditional technology
 Instant adjustment to temperature and relative humidity
changes
 Low operating sound level
 Highly flexible solutions: multiple sizes, piping topologies and
connection valves
FWP-AT
FWECA
FWP-AT
02
03
04
05
06
07
5.08
2.12
3.6
1.52
10.31
4.56
5.45
2.43
3.87
1.67
11.39
4.77
5.99
3.38
80
17.5
6.47
2.67
4.4
1.78
12.28
4.94
2-pipe
Cooling capacity
Total capacity
Heating capacity
Sensible
capacity
2-Pipe
4-Pipe
Power input
Dimensions
Weight
High
Low
Unit
High
Low
High
Low
High
Low
High
Low
Height
Width
Depth
Unit
Operation weight
Heat exchanger
Water volume
Additional heat exchanger Water volume
Water flow
Cooling
Heating
Additional heat exchanger
Water pressure drop Additional heat exchanger
Fan
Type
Quantity
Air flow rate
High
Low
Available pressure High
Sound power level High
Sound pressure level High
Electric heater
Power input
Piping connections Drain
OD
Water connections Std. heat exchanger
Add. heat exchanger
Power supply
Phase/Frequency/Voltage
Control systems
Wired remote control

kW
kW
kW
kW
kW
kW
kW
kW
W
W
mm
mm
mm
kg
kg
l
l
l/h
l/h
l/h
kPa
m³/h
m³/h
Pa
dBA
dBA
kW
mm
inch
inch
Hz/V
2.61
1.34
1.88
0.95
5.47
2.77
3.14
1.5
2.16
1.02
6.01
2.91
3.14
1.95
46.4
12.2
3.49
1.67
2.34
1.1
6.47
3.00
239
1,039
1,389
609
23
24
1.1
448
480
24
26
31
33
26
28
33
35
1.5
2.2
1.6
2.1
0.4
0.6
539
598
873
936
527
567
904
999
275
526
3
5
Centrifugal - forward blades - directly coupled on fan motor
1
400
800
180
300
71
65
55.6
60.6
44.1
49.1
2
2.5
16
3/4
3/4
1~/50/230
FWEC3A
35
38
3.2
1,111
1,077
FWB-BT
Medium ESP ducted unit
AC fan motor unit for horizontal concealed mounting
 Compact dimensions, can easily be mounted in a narrow ceiling
void
 ,  or  stage row cooling coil
 Drain pan to collect the condensate from: heat exchanger and
regulating valves
 7-speed electrical motors (with thermal protection on windings)
 All  speeds pre-wired in the factory in the terminal block of the
switch box
 Washable air filter, easily removable for maintenance
FWB-BT
FWEC,,A
FWB-BT
Cooling capacity
Total capacity
Heating capacity
Sensible
capacity
2-Pipe
4-Pipe
Power input
Dimensions
Weight
High
Low
Unit
High
Low
High
Low
High
Low
High
Low
Height
Width
Depth
Unit
Operation weight
Heat exchanger
Water volume
Additional heat exchanger Water volume
Water flow
Cooling
Heating
Additional heat exchanger
Water pressure drop Additional heat exchanger
Fan
Type
Quantity
Air flow rate
High
Low
Available pressure High
Sound power level High
Sound pressure level High
Electric heater
Power input
Piping connections Drain
OD
Water connections Std. heat exchanger
Add. heat exchanger
Power supply
Phase/Frequency/Voltage
Current input
High
Medium
Low
Control systems
Wired remote control
kW
kW
kW
kW
kW
kW
kW
kW
W
W
mm
mm
mm
kg
kg
l
l
l/h
l/h
l/h
kPa
m³/h
m³/h
Pa
dBA
dBA
kW
mm
inch
inch
Hz/V
A
A
A
02
2.61
1.34
1.88
0.95
5.47
2.77
23
24
1.1
448
480
03
04
05
06
07
08
2-pipe
3.14
3.49
5.08
5.45
6.47
7.57
1.50
1.67
2.12
2.43
2.67
4.18
2.16
2.34
3.6
3.87
4.4
5.23
1.02
1.1
1.52
1.67
1.78
2.95
6.01
6.47
10.31
11.39
12.28
15.05
2.91
3.00
4.56
4.77
4.94
8.63
3.14
5.99
1.95
3.38
79
154
28
64
239
1,039
1,389
609
24
26
31
33
35
43
26
28
33
35
38
45
1.5
2.2
1.6
2.1
3.2
2.1
0.4
0.6
539
598
873
936
1,111
1,299
527
567
904
999
1,077
1,319
275
526
3
5
Centrifugal - forward blades - directly coupled on fan motor
1
2
400
800
180
300
71
65
56
59
44.5
47.5
2
2.5
16
3/4
3/4
1~/50/230
0.36
0.73
0.21
0.60
0.14
0.33
FWEC1A / FWEC2A / FWEC3A
09
10
8.67
4.64
5.96
3.21
16.85
9.29
12.8
7.67
294
155
10.34
5.35
6.9
3.57
18.78
9.85
1,739
45
48
2.8
1.7
1,488
1,479
1,123
8
48
52
4.2
1,774
1,647
3
1,200
600
59
69
57.5
3
1
1.28
0.90
0.70
373
FWD-AT/AF
High ESP ducted unit
AC fan motor unit for horizontal or vertical concealed
mounting
 Straight duct connector mounted to discharge side
 Washable air filter, easily removable for maintenance
FWD-AT/AF
FWEC,,A
Cooling capacity
Heating capacity
Power input
Dimensions
Weight
Heat exchanger
Additional heat exchanger
Water flow
Total capacity
Sensible capacity
2-Pipe
4-Pipe
High
Low
Unit
High
High
High
High
Height
Width
Depth
Unit
Water volume
Water volume
Cooling
Heating
Fan
Type
Quantity
Air flow rate
High
Available pressure High
Sound power level High
Piping connections Drain
OD
Water connections Std. heat exchanger
Power supply
Phase/Frequency/Voltage
Current input
High
Medium
Low
Control systems
Wired remote control

FWD-AT/AF
04
kW
kW
kW
kW
W
W
mm
mm
mm
kg
l
l
l/h
l/h
3.90
3.08
4.05
m³/h
Pa
dBA
mm
inch
Hz/V
A
A
A
234
130
754
33
1.06
674
674
1
800
66
66
0.95
0.74
0.57
06
08
10
2-pipe
6.20 7.80 8.82
4.65 6.52
7.16
7.71
9.43 10.79
349
443
247
261
280
964
1,174
559
41
47
49
1.42
1.79
2.38
1,064 1,339 1,514
1,064 1,339 1,514
12
16
18
04
06
08
10
12
16
18
4-pipe
11.90 16.40 18.30 3.90 6.20 7.80 8.82 11.90 16.40 18.30
9.36 12.80 14.10 3.08 4.65 6.52
7.16
9.36 12.80 14.10
14.45 19.81 21.92
4.49 6.62
9.21
15.86
21.15
714
1,197
234
349
443
714
1,197
328
704
130
247
261
328
704
352
280
352
1,384
754
964
1,174
1,384
718
559
718
65
77
80
35
43
50
52
71
83
86
2.5
4.02 5.03
1.06
1.42
1.79
2.38 2.50 4.02 5.03
0.35 0.47
0.59
1.42
1.72
2,056 2,833 3,140 674 1,064 1,339 1,514 2,056 2,833 3,140
2,056 2,833 3,140 349
581
808
1,392
1,856
Centrifugal multi-blade, double suction
2
1
2
1,250
1,600
2,200
3,000
800 1,250
1,600
2,200
3,000
58
68
64
97
145
134
63
53
63
59
92
138
128
69
72
74
78
66
69
72
74
78
16
3/4
1
3/4
1
1~/50/230
1.58
1.97
3.21
5.37
0.95
1.58
1.97
3.21
5.37
1.39
1.52
2.08
4.38
0.74
1.39
1.52
2.08
4.38
1.18
1.20
1.50
3.26
0.57
1.18
1.20
1.50
3.26
FWEC1A / FWEC2A / FWEC3A
375
Daikin air handling units, with their plug-and-play
design and inherent flexibility, can be configured and
combined specifically to meet the exact requirements
of any building, no matter what it is used for or who is
to work there. Our systems are designed to be the most
environmentally friendly and the most energy efficient
on the market, thus reducing their ecological impact,
while, at the same time, keeping costs down through
the minimisation of energy consumption.
When combined with the small physical footprint of
the system, these features make our air handling units
ideal for all markets.
376
Air handling units
Why choose Daikin airhandling units? 378
Products overview
Software and Eurovent certification
The working principle at a glance
Compact
Professional
Easy
Energy
Fresh air package
382
383
384
386
388
389
390
392
377
ARGUE CARDS
Daikin Air handling units
Why choose Daikin air handling units?
t
Energy efficiency and indoor air quality
t
Wide range of air handling units
t )JHIRVBMJUZ in component selection
t *OOPWBUJWF technology
t
Operation FGGJDJFODZ and energy TBWJOHT
t
Outstanding SFMJBCJMJUZ and QFSGPSNBODF
t
Various applications are possible including air conditioning applications, industry-type process cooling,
and large-scale district heat source systems.
Benefits for the installer
› Easy start-up and commissioning through pre-programmed DDC
controller and external terminal connection avoiding drilling into
unit panels
› Internal electrical wiring saves installation time
› Flush mounted electrical control panel avoids risk of damage
during transportation and installation
Benefits for the consultant
› In-house developed ASTRA software with dedicated control
interface allowing for a professional report in a few clicks
Benefits for the end user
› Higher degree of control than ever before, allowing the user
to determine a wide range of settings, resulting in excellent
operational flexibility
› For units higher than mm, the electrical panel is fully
embedded into the unit
378
Marketing tools
› Watch the time-lapse video of a Daikin AHU
construction on www.youtube.com/
daikineurope
› Brochure on air handling units as a combined
solution with refrigeration and chillers on
commercial applications
Packaged control solution for Daikin AHU
› Electrical control panel complete with
› Direct Digital Control (DDC) controller
› Internal fitting of all sensors & pressure
measurements devices
› Built-in temperature, humidity and CO sensors
› Internal electrical wiring for all components
Energy efficient while focusing
on maximum comfort
› Set points can be specified for supply, return
or room temperature
› Control of all AHU components such as mixing
dampers, heat recovery wheels, water valves,
pressure switches for filters and fans, fan motors
and inverters
Plug and play design
› Low voltage fast connectors in between
AHU sections
Easy start-up and commissioning
› Pre-programmed and factory-tested controls
ensuring all wiring is installed correctly
› Reduced energy and operating costs
379
Air Handling Units
SMART CONTROLS
ENERGY EFFICIENT FAN
380
Air Handling Units
COMMERCIAL AND
INDUSTRIAL APPLICATIONS
COMFORTABLE
INDOOR CLIMATE
381
Air handling units
Overview D-AHU range
Professional
› Pre-configured sizes
› Tailored to the individual customer
› Modular construction
Air flow (m/h x ,)
Professional
Energy
140
› High-end solution for optimised
energy consumption
› High efficiency components
› Strong Return on Investment
120
Easy
Energy
100
› Space-optimized unit
› Pre-configured sizes
NEW Compact
› Pre-configured sizes
› Plug & Play concept
› EC Fan Technology
› High Efficiency Heat Wheel
› Compact Design
90
80
70
60
50
40
Easy
Compact
20
 m/h
up to , m/h
0
382
 m/h
up to , m/h
 m/h
up to , m/h
m/h
up to , m/h
Air handling units
Software
ASTRA Pro
ASTRA is the powerful software that Daikin has
developed to offer a RVJDL and DPNQSFIFOTJWF
TFSWJDF for the customer in order to make the
technical choice and the FDPOPNJDWBMPSJ[BUJPO
of each air handling unit. It is a complete tool that
can configure any type of product and respond
exactly to the strictest design needs. The result is
a comprehensive FDPOPNJD offer including all the
technical data and drawings, the psychrometric
diagram with the relative air treatment and the fans’
performance curves. However, Daikin didn’t stop
there, they went further.
NEW
ASTRA Xpress
› Quick AHU selection that will save you precious
time, drastically reducing selection time through
the new software interface.
› Very competitive solution available within
the Wizard thanks to pre-uploaded parameters.
› High selection quality, thanks to the huge number
of the pre-engineered units embedded within the
software.
MECCANO is the other powerful software developed
and designed to quickly DPOWFSUUIFPòFSJOUIF
FYFDVUJWFPSEFS. Technical drawings to be sent and
approved by the client, executive drawings for the
production, bill of material, code generation for each
component used are just a few of the many functions
of the instrument.
The ASTRA-MECCANO integration has therefore made
possible the complete automated management of
the process bySFEVDJOHUIFUJNFPGUIFPòFS and
of the delivery and improving the service to our
customers.
4 steps to configure an air handler in just 2 minutes
1
Select a configuration
2
3
Select coils
4
Design conditions ----> Print report
Select other components
Eurovent certification
Daikin is participating in the Eurovent Certification
Programme for Air Handling Units. They are certified
under the number 11.05.003 and presented on
www.eurovent-certification.com
Daikin air handling units
AHU N°: 11.05.003
Range: D-AHU
Eurovent Classification according to EN1886
Result sp65
Casing mechanical strength
Casing mechanical strength
D1
Casing air leakage
Negative pressure -400 Pa
L1
Casing air leakage
Positive pressure +700 Pa
L1
Filter bypass leakage
F9
Thermal transmittance
T2
Thermal bridging of
the casing
TB2
Casing Class
Maximum relative deflection mm x m-1
Casing air leakage Negative pressure -400 Pa
Leakage Class
Maximum leakage rate (f400) l x s-1 x m-2
Casing air leakage Positive pressure +700 Pa
Leakage Class
Maximum leakage rate (f 700) l x s-1 x m-2
Filter bypass leakage
Filter Class
Maximum filter bypass leakage rate k in % of the volume flow rate
Thermal transmittance
Class
Thermal transmittance (U) W/m2 x K
Thermal Bridging of the casing
Class
Thermal bridging facto (kb) W x m-2 x K-1
D1
4.00
D2
10.00
D3
EXCEEDING10
L1
0.15
L2
0.44
L3
1.32
L1
0.22
L2
0.63
L3
1.90
F9
0.50
F8
1
F7
2
F6
4
G1 TO F5
6
T1
U <= 0.5
T2
0.5 < U <= 1
T3
1 < U <= 1.4
T4
1.4 < U <= 2
T5
No requirements
TB1
0.75 < Kb <= 1
TB2
TB3
TB4
0.6 < Kb <= 0.75 0.45 < Kb <= 0.6 0.3 < Kb <= 0.45
TB5
No requirements
383
Air handling units
The working principle at a glance
Typical configurations for Daikin air handling units
provide a versatile range of functions.
Our system offers numerous options for
customisation through an extensive range of
variations and added functionality.



Supply side



Damper section including ventilation
grilles, factory-mounted actuators
Bag filter with factory-mounted
differential pressure manometer and
hinged door
Exhaust air
Heat recovery system
(plate heat exchanger or rotation heat
exchanger)

Mixing box with damper and factorymounted actuators

R-410A with heat recovery system with
galvanised condensate tray and drip
protection

Supply air fan (with hinged door, opening,
drive monitoring, mounted and cabled
lighting and ON/OFF switch)
Fresh air

Fans
› Forward curved fan
› Backward curved fan
› Backward airfoil blades fan
› Plug fan
› EC plug fan
384
Exchangers
› Water coils
› Steam coils
› Direct expansion coil
› Superheated water coils
› Electric coils



Humidifiers
› Evaporative humidifier without pump (loss water)
› Evaporative humidifier with re-circulating pump
› Air washer without pump (loss water)
› Air washer with re-circulating pump
› Steam humidifier with direct steam production
› Steam humidifier with local distributor
› Atomized water spray humidifier
Air handling units
Control system on plug and
play solution basis
›
›
›
›

Unique section to section thermal break profile
Air temperature control
Chilled water and DX cooling system control
Free cooling
CO automatic control
› Thermal bridge free for the entire AHU
› Smooth interior surface with improved IAQ
(Indoor Air Quality)
Conventional design
Daikin design

Return side

Bag filter with factory-mounted
differential pressure manometer
and hinged door.

Exhaust air fan (with hinged
door, opening, drive monitoring,
mounted and cabled lighting and
ON/OFF switch)

Mixing box with damper and
factory-mounted actuators

Heat recovery system (plate heat
exchanger or rotation exchanger)

Damper section including
ventilation grilles, factory-mounted
actuators
Return air
Supply air

Heat recovery systems
› Heat wheel, sensible or sorption
› Plate heat exchanger (optional
bypass)
› Run-around coils

Other section
› Attenuator section
› Mixing box section
with actuators or manual
controlled dampers
› Empty section
Filters
› Synthetic pleated filter
› Flat filter aluminium mesh
› Rigid bag filter
› Soft bag filter
› High efficiency filter
› Carbon absorption filter
› Carbon deodorizing filter
Accessories
› Control features
› Frost protection
› Manometers
› Drive guard
› Roof
›…
385
Air handling units
Compact
High-end solution with heat recovery
Energy efficiency and
indoor air quality
›
›
›
›
›
›
›
›
›
›
›
Predifined sizes
Plug & Play design: prewired and factory-tested
EC fan technology
IE premium efficiency motor
High efficiency heat wheel (heat recovery)
Compact design
Advanced control features
Easy installation
User friendly selection
Eurovent certified
Indoor air quality compliant with
VDI  hygiene guideline
› Control logic : Supply, Ambient and
Return Temperature
› Operating limits from - °C, - °C with
electric heaters, up to + °C ambient temperature
› DX or chilled water cooling coil
› VRV IV and ERQ coupling capability
› Silencers
› Humidifier module
› Indoor and outdoor versions
› Air flow or pressure control (Variable Air Volume - Constant Air Volume)
› Free cooling capability
› Economy and Night operation
› Time Scheduler
› IAQ through CO sensor
› Monitoring and control through Daikin ITM
› Monitoring of the energy consumption
EC Fan
› Air flow control via measuring
at the inlet nozzle (VAV - CAV)
› Easy commissioning
› Nominal air flow
programmed at factory
› Silent operation
386
Air handling units
VFD
Sine filter
Installation –
simple and safe
Shielded cables
no need for cost-intensive adjustments
before commissioning or for grounding
and shielding measures. Plug-and-Play
is that simple in ventilation and airconditioning technology.
Main supply
Main supply
Motor protection Grounding
Airflow rate
Temp efficiency winter
ESP nominal
Power input
Height
Width
Depth
Weight
SFPv
Power supply
D-AHU
m3/h
%
Pa
kW
mm
mm
mm
kg
kW/m3/s
Hz/V
1
1,200
81.3
200
0.311
1,320
1,700
720
325
1,866
2
1,700
81.1
200
0.447
1,320
1,700
820
350
1,893
1~ / 50 / 230
3
2,700
81.4
200
0.748
1,540
1,800
990
475
1,995
4
4,100
81.6
200
0.992
1,740
1,980
1,200
575
1,742
5
5,500
82.6
200
1.29
1,740
2,080
1,400
750
1,689
6
6,100
81.2
200
1.48
1,920
2,280
1,400
790
1,747
7
7,000
82.7
200
1.65
1,920
2,400
1,600
950
1,697
3N~ / 50 / 400
8
9,100
81.4
200
1.88
2,180
2,450
1,940
1,330
1,487
9
11,500
81.5
200
1.37
2,460
2,280
1,940
1,410
1,715
10
15,000
83.2
200
1.76
2,570
2,400
2,300
1,750
1,689
Above data refers to standard air performance sizes
Air performance STD (standard performance)
Air performance HP (high performance)
(Pa) Max. available ESP (supply)
(Pa) Max. available ESP (supply)




























Airflow (M/h)



Airflow (M/h)
Size 
Size 
Size 
Size 
Size 
Size 
Size 
Size 
Size 
Size 
Size 
Size 
Size 
Size 
Size 
Size 
387
Air handling units
Professional
The most flexible solution
Pre-defined family of sizes
Twenty-seven (27) fixed sizes optimized for
the most cost effective selection and manufacturing
standardization.
Infinitely variable sizing
› Dimensions (width and height) can vary with
a cm small increment to match individual customer
needs and to reach
an increased efficiency of the heat wheel.
› Air flow from  m/h up to , m³/h
› All the sizes are modular manufactured to facilitate
the transport and the assembly on site.
Pre-defined sizes - Overall dimensions
Size
1
2
3
4
5
6
7
8
9
10
11
12
13
Air Flow (m3/h) Height - mm
1,105
550
1,550
600
1,980
650
2,600
780
3,170
780
3,550
800
4,000
800
4,800
850
5,560
900
6,600
900
7,950
1,100
9,320
1,100
10,050
1,150
Width - mm
850
900
950
1,100
1,150
1,150
1,250
1,300
1,350
1,550
1,550
1,650
1,650
Infinitely variable sizes
Size
14
15
16
17
18
19
20
21
22
23
24
25
26
27
Air Flow (m3/h) Height - mm
13,200
1,400
19,200
1,500
25,300
1,580
31,500
1,750
37,000
1,800
43,400
2,100
51,300
2,250
58,000
2,250
67,500
2,400
78,000
2,450
84,700
2,700
98,000
2,850
111,000
2,850
124,000
3,000
Example
Flexible sizing for AHU optimization
›  cm increment for width & height dimensions
› No additional cost for customized unit size
› No additional lead time
Air Flow
(m3/h)
15.000
Unit Size
Height mm
Width mm
STD 15
1,500x1,750
1,500
1,500
2,100
1,750
Plug and play: More control, more flexibility
The new plug and play control system gives
end-users a higher degree of control than ever
before, allowing the user to determine
a wide range of settings, resulting in excellent
operational flexibility.
The factory-fitted electrical control panel,
complete with Direct Digital Control (DDC) controller,
is combined with in-built temperature, humidity
and CO2 sensors to control mixing dampers,
388
Width - mm
1,850
2,100
2,650
2,750
3,240
3,090
3,340
3,820
4,040
4,490
4,490
4,890
5,490
5,990
heat recovery wheels, water valves, pressure switches
for filters and fans, fan motors and inverters.
All these components are wired internally and
individual AHU modules are linked by fast connectors.
The AHU control system can manage the chilled
water coil, hot water coil, DX cooling and/or heating
coil(s) (in conjunction with ERQ/VRV) of single
or multiple refrigerant circuits (up to a maximum
of four circuits per DX coil).
Face
Velocity
m/s
1,95
2,46
Air handling units
Easy
Quick solution for climate control
The range covers an area of air flow rates from
500 m3/h up to 30,000 m3/h*, with the possibility
to choose the more appropriate face velocity,
depending on the treatment required.
Pre-defined sizes
Fifteen fixed sizes optimized to reach the best
compromise between competitiveness and
manufacturing standardization.
Variable Dimensioning
Designed to overcome installation constraints
where space requirements of the section
“height x width” must be adapted to the available
space. The system gives the possibility to tailor
the unit sizes through increments of 1 cm average.
Pre-defined sizes - Overall dimensions
Air Flow (m3/h)
Height - mm
Speed 2.5 m/s
Size
Std 1
Std 2
Std 3
Std 4
Std 5
Std 6
Std 7
Std 8
Std 9
Std 10
Std 11
Std 12
Std 13
Std 14
Std 15
1,105
1,550
1,980
2,600
3,170
3,550
4,000
4,800
5,560
6,600
7,950
9,320
10,050
13,200
19,200
Width - mm
Example
850
900
950
1,100
1,150
1,150
1,250
1,300
1,350
1,550
1,550
1,650
1,650
1,850
2,100
Air Flow
(m3/h)
550
600
650
780
780
800
800
850
900
900
1,100
1,100
1,150
1,400
1,500
15,000
Unit Size
Height mm
Width mm
STD 15
1.500x1.700
1,500
1,500
2,100
1,700
Face
Velocity
m/s
1.95
2.48
Infinitely variable sizes
Flexible sizing for AHU optimization
›  cm increment for width & height dimensions
› No additional cost for non-standard unit size
› No additional lead time
*Air Flow limits of  m/h and , m/h are calculated using non standard sizes (max dimensions ,x,) and considering . m/s coil face velocity
D-AHU Easy 1-8
D-AHU Easy 9-15
Size

Size
.

.



.

.
. (m/h) )

.

.

.

.
.

.
Air Flow / (m/h)

.
.

Speed . m/s

.

.

.

.

.

.
Speed . m/s
Speed . m/s

.
Speed . m/s

. (m/h)

.

.












Speed . m/s
Speed . m/s




Air Flow / (m/h)
389
Air handling units
Energy
High-end solution for the highest
energy efficiencies
High efficiency
heat recovery
The D-AHU Energy series is equipped
with high efficiency heat recovery
system with rates up to 90%. Various
models are available with a heat
recovery system equipped with
a condensation wheel, an enthalpy
wheel or a sorption wheel.
Premium efficiency motor
Premium efficiency motors in line with
EU regulation (EC) no. 640/2009 are available for
the Energy series in order to further reduce electrical
power consumption.
High efficiency fan
Fans with double-width, double-inlet and backward
curved airfoil blades are available with efficiencies
of up to 85% as well as reinforced bearings
for longer lifespan.
Plug and play controls
Daikin has developed a control system to
efficiently manage all components selected either
independently or through an external supervision
system. The control package includes the control
panel, advanced microprocessor and in-built sensors
for temperature, humidity and air quality.
390
Air handling units
Return on investment
An air handling unit is critical to an effective climate
control system and, although the initial investment
can appear high,
the savings generated by our advanced designs and
operating efficiencies guarantee a rapid return on
the investment made. Our D-AHU Energy series has
AHU Life Cycle Cost (LCC)
€
been designed to deliver exceptional performance
thus driving down the energy consumed and so
lowering energy bills. Taken over the expected
15-year life-span of the equipment, this will result
in an enormous saving, especially in a time of ever
increasing energy prices.
Standard Series
D-AHU Energy Series
Savings
Break-even Point
Time
Competitor
Daikin
Specific Fan Power (SFP) is a measure used
in the evaluation of the energy consumed by an
air handling unit. As defined in EN 13053 and
EN 13779, the lower the SFP, the lower the
power consumption of the entire air handling unit.
The D-AHU Energy has been designed to deliver
Energy consumption
Capital Cost
Maintenance
Savings
the lowest possible SFP by using the most efficient
components designed to provide the perfect
solution series to your needs. It is an optimized
answer to the European directive on the energy
performance of buildings (EPBD) that seeks
to reduce the impact on global warming.
391
Air handling units
Daikin Fresh Air package
High Efficiency
High Comfort Levels
Daikin heat pumps are renowned for their high
energy efficiency. The VRV range offers both heat
pump and heat recovery units with part load
efficiencies as high as 9.02. Integrating the AHU
with a heat recovery system is highly effective since
an office system can frequently be in cooling mode
while the outdoor air is too cold to be brought inside
in an unconditioned state. In this case heat from
the offices is merely transferred to heat up the cold
incoming fresh air. In the absence of an AHU
this ‘free heating’ of incoming fresh air would
not be possible.
Daikin ERQ and VRV units respond rapidly
to fluctuations in supply air temperature, resulting
in a steady indoor temperature and resultant
high comfort levels for the end user.
The ultimate is the VRV range which improves
comfort even more by offering continuous heating,
also during defrost.
VRV IV or ERQ
condensing unit
Factory fitted and welded
fresh air package
392
Expansion valve
Electronic interface
(EKEXV)
(EKEQ-FCB)
Daikin offers a wide range
of condensing units for cooling
and freezing applications.
Daikin refrigeration units combine
efficiency and reliability with easy
installation and maintenance.
394
Refrigeration
Why choose Daikin refrigeration? 396
ZEAS condensing units
LREQ-BY1402
Conveni-Pack
LRYEQ-AY1404
Booster unit
LCBKQ-AV1409
Commercial condensing units
JEHCCU-M/L & JEHSCU-M
410
Large variable capacity condensing unit
ICU413
For more information on Options & Accessories, please
refer to page 466 of this catalogue.
395
ARGUE CARDS
Refrigeration
ICEBAR - London
Why choose Daikin refrigeration?
Marketing tools
r High efficient solutions to match your
refrigeration needs
Visit the website: http://www.daikineurope.com/refrigeration
Download the software:
Extranet > Software Downloads > Refrigeration Xpress
r For commercial and industrial applications
r Innovative and reliable technology – proven
and tested for VRV (ZEAS and Conveni-Pack)
r Compliant with new F-Gas regulation (R-410A)
r Across Europe, thousands of Daikin refrigeration
systems running on R-410A, such as its ZEAS
Benefits for the installer
and Conveni-Pack ranges, are used in a wide
› Plug and play solutions
› Factory-tested
› Compact design for restricted installation space
range of applications, from food retail to industry.
r Urban proof solutions in terms of compact
dimensions and low sound levels
Benefits for the consultant
› Daikin ZEAS identified as best available technology
according to Eco-design
› Easy and intuitive selection of outdoor condensing
units with Refrigeration Xpress
› Wide range to match most refrigeration needs
Benefits for the end user
› High efficient solutions with innovative technology
for lower running costs
› Heat recovery technology on Conveni-Pack
› Proven reliability and high performance
› Ideal for urban applications
396
F-Gas compliant
Daikin refrigeration units are ready to meet the
targets of the new F-Gas regulation.
01/01/2020
v ic e a n d m ai n t e n
an
b
s
t
rke
ma
he
ce
an
uipment p
la
ew eq
c
e
nn
do
no
n
Ba
t
Ser
01/01/2030
Service ban on recycled HFCs with GWPs of 2500
or more
Service ban on use in the maintenance or servicing
of existing refrigeration equipment with a charge
size of 40 tonnes of CO2 eq or more - provided they
have been recovered from the equipment. Can only
be used by the firm that recovered it or by the firm
whose installation it was recovered from.
Ban onHFCs with GWPs of 2500
or more
Applies to stationary refrigeration
equipment or it’s associated remote
plant. Equipment operating below
-50 deg C is exempt
01/01/2030
Service ban on reclaimed HFCs with GWPs of 2500 or more
Used for the maintenance or servicing of existing refrigeration
equipment with a charge size of 40 tonnes of CO2 eq or more –
provided they are labelled appropriately.
01/01/2022
Ban on HFCs with GWP of 150 and over
Applies to multipack centralized refrigeration systems for
commercial use with a rated capacity of 40kW or more - except
where used in the primary refrigerant circuit of cascade systems,
where HFCs with a GWP of less than 1500 may be used
01/01/2020
Service ban on HFCs with GWPs of 2500 or more
Applies to refrigeration equipment with a charge
size of 40 tonnes CO2 eq or above.
* Regulation n° 517/2014 on fluorinated greenhouse gases of 16 April 2014
Your References
Project BÄKO WEST eG - Bochum (Germany)
Ingo Burmeister of BÄKO West explains: “We wanted
a future-proof, energy efficient and proven
technology with high reliability. At the same time,
we sought to minimise on-going maintenance and
repair costs along with lowering our energy bills.”
Six Daikin ZEAS units provide a cooling capacity of
A key challenge was to remodel an existing
74 kW to the frozen foods area, while a further six
standard cooling area into a freezer room. This was
providing a cooling capacity of 171 kW to the
possible after four weeks of drying.
chilled foods zone.
397
Refrigeration
ZEAS LREQBY1
ZIGGO DOME, EVENT HALL
ZEAS FOR COOLING 6 AND FREEZING 2
CHILLED WITH ZEAS

Refrigeration
BÄKO WEST EG, BAKERY COOPERATIVE
ZEAS FOR COOLING 6 AND FREEZING 6
E. LECLERC, HYPERMARKET
ZEAS
EDEKA, SUPERMARKET
CONVENIPACK 2 AND ZEAS 1

KEEP COOL, SAVE MONEY
Daikin refrigeration products are designed to reduce environmental impact. That’s why
Daikin ZEAS and Conveni-Pack already comply with the new F-gas regulation that enters
into force on 1 January 2015. Daikin systems also set industry standards when it comes to
energy efficiency. Which enables you to save money while you help save the planet.
Learn more at www.daikineurope.com/refrigeration
400
Refrigeration
Products overview
Model
Product name
Capacity (kW)
0
2
5
10
25
50
100
150
300
450
ZEAS
LREQ-BY1
Inverter condensing
unit for commercial
refrigeration
Multi ZEAS
LREQ-BY1
Integrated solution
for chilling, freezing
Conveni-Pack
and comfort cooling
LRYEQ-AY1
and heating
Booster unit to allow
both ZEAS and
Booster unit
Conveni-Pack
LCBKQ-AV1
freezing applications
Commercial condensing units
CCU
with reciprocating technology
JEHCCU-M1/M3/L1/L3
JEHCCU-CM1/CM3
Commercial condensing units
with scroll technology
SCU
JEHSCU-M1/M3/L3
JEHSCU-CM1/CM3
Inverter
condensing unit for industrial
ICU
ICUHS-HA
refrigeration
Chilling
Freezing
Air conditioning
Heating
401
ARGUE CARDS
ZEAS condensing unit
for refrigeration
Why choose ZEAS?
Marketing tools
r Best available technology according to Eco-design
Visit the minisite on www.daikineurope.com
Download the selection software from the Extranet >
Software Downloads > Refrigeration Xpress
r R-410A refrigerant: already compliant with new
F-Gas Regulation
r Small footprint
r Low sound level
High energy efficiency
› Daikin inverter scroll compressor with
economizer technology
› DC inverter fan technology (Ecodesign compliant)
› Efficient floating evaporator pressure control
› High efficient oil recovery system
Fully packaged unit for excellent reliability
and performance
› Error-proof component selection
› In-built controls
› Factory leak-tested and pre-charged
Benefits for the installer
› Reduced delivery time thanks to European
manufacturing plant
› Reduced piping requirements and installation time
› Compact design, with reduced foot print
› Integrated electrical & control box
› Unit already pre-charged with refrigerant
Benefits for the consultant
› One model can cover for most refrigeration needs
in the market
› Wide capacity range (12.5 till 71.0*kW)
› High modularity of the refrigeration system
› Suitable to indoor installations through the use of
high ESP fans
*Preliminary for 2xLREQ20BY1R
Small foot print and low weight
› Very compact design
› Easy to install, even in small spaces
Low sound level
› Low noise compressors
› High grade sound insulation on both panels
and compressors
› Specially designed fan blades to limit
sound emissions
› 3 additional low noise mode
› Night operation mode
402
Benefits for the end user
› Reduced costs and low environmental impact
› Small footprint and low weight requiring only light
weight supporting structures
› A neighbourhood-friendly choice with its special
night operation mode
LREQ-BY1
ZEAS condensing unit for
commercial refrigeration with
scroll technology
Refrigeration solution for medium to large capacity
applications featuring proven VRV technology
 Perfect solution for all cooling and freezing applications with
variable load conditions and high energy efficiency requirements.
In particular used in supermarkets, cold storage, blast coolers and
freezers etc.
 DC inverter scroll compressor with economiser function results in
high energy efficiency and reliable performance
 Reduced CO emissions thanks to the use of R-A refrigerant
 Factory tested and pre-programmed for quick and easy
installation and commissioning
 Increased installation flexibility thanks to limited dimensions
 Low sound level including „night mode“ operation
 For small freezing capacity, single ZEAS units can be connected to
a booster unit
 Multi combination of  x  HP or  x  HP resulting in less
pipework and installation time
Medium and Low Temperature Refrigeration
LREQ-BY1
System
Outdoor unit module 1
Outdoor unit module 2
Refrigerating
Medium temperature Nom.
kW
capacity
Low temperature Nom.
kW
Medium temperature Nom.
kW
Power input
Low temperature Nom.
kW
Dimensions
Unit
Height
mm
Width
mm
Depth
mm
Weight
Unit
kg
Heat exchanger
Type
Compressor
Type
Piston displacement
m³/h
Speed
rpm
Output
W
Starting method
Compressor 2
Speed
rpm
Output
W
Compressor 3
Speed
rpm
Output
W
Fan
Type
Quantity
Air flow rate
Cooling Nom.
m³/min
Fan motor
Output
W
Drive
Fan motor 2
Output
W
Sound pressure level Nom.
dBA
°CDB
Operation range Evaporator
Cooling Min.~Max.
Ambient temperature Min.~Max.
°C
Refrigerant
Type
Charge
kg
Control
Refrigerant oil
Type
Charged volume
l
Piping connections Liquid
50m or less
50~130m
Gas
50m or less
50~130m
Power supply
Current
Current

Phase/Frequency/Voltage
Running current (RLA)
Starting current (MSC)
Nom.
5
LREQ-BY
6
8
10
12
15
20
12.5
15.2
19.8
23.8
26.5
33.9
37.9
5.51
6.51
8.33
10.0
10.7
13.9
15.4
5.10
6.56
8.76
10.6
12.0
15.2
17.0
4.65
5.88
7.72
9.27
9.89
12.8
14.1
1,680
635
930
1,240
765
166
242
331
337
Cross fin coil
Hermetically sealed scroll compressor
11.18
13.85
19.68
23.36
25.27
32.24
35.8
5,280
6,540
4,320
6,060
6,960
5,280
6,960
2,600
3,200
2,100
3,000
3,400
2,600
3,400
Direct on line (inverter driven)
2,900
3,600
2,900
3,600
Propeller fan
1
2
95
102
171
179
191
230
240
350
750
350
750
Direct drive
350
750
55.0
56.0
57.0
59.0
61.0
62.0
63.0
-45~10
-20~43
R-410A
5.2
7.9
11.5
Electronic expansion valve
Daphne FVC68D
1.7 §$ 2.5
1.7 §$ 2.1 §$ 3.0
1.7 §$ 2.1 §$ 4.0
ø 12.7 C1220T
ø 9.5 C1220T (Brazing connection)
(Brazing connection)
ø 9.5 C1220T
ø 12.7 C1220T (Brazing connection)
(Brazing connection)
ø 22.2 C1220T
ø 28.6 C1220T (Brazing
ø 34.9 C1220T
(Brazing connection)
connection)
(Brazing connection)
ø 22.2 C1220T
ø 28.6 C1220T
ø 34.9 C1220T
(Brazing connection)
(Brazing connection)
(Brazing connection)
Hz/V
3~/50/380-415
A
7.1/-/9.2/-/5.3/7.5/7.4/7.9/9.8/8.3/- 7.0/8.2/8.2 9.5/8.4/8.4
A
74
75
84
30
40
LREQ15BY1R LREQ20BY1R
LREQ15BY1R LREQ20BY1R
67.8
75.8
27.8
29.6
30.4
34.0
25.6
27.6
65.0
66.0
-~-~ø 19.05 C1220T
(Brazing connection)
ø 19.05 C1220T
(Brazing connection)
ø 41.28 C1220T
(Brazing connection)
ø 41.28 C1220T
(Brazing connection)
/-/-/-/109
115
ARGUE CARDS
Conveni-Pack, integrated
solutions for freezing, chilling,
space heating and cooling
Why choose Conveni-Pack?
Conveni-Pack is designed for supermarkets and smaller retail outlets, to help lower energy consumption
and reduce CO2 emissions. It is the first mass-produced, whole-building system to combine normal
and low temperature refrigeration with air conditioning, heating and ventilation in one circuit.
At the coldest times of the year, all the waste heat from food refrigeration is recovered and re-used for
space heating, resulting in energy savings of up to 40%. The heat recovery function of Conveni-Pack
together with its optimised controls and inverter compressor technology, ensures savings of up
to 60% on energy costs during one year alone.
Energy efficient heat recovery
› Conveni-Pack recovers up to % of the heat
extracted from supermarket refrigeration cases
and re-uses it to heat the retail space at no
additional cost.
Heat
Recovery
Benefits for the installer
› VRV technology ensuring optimised installation and maintenance
› Reduced piping requirements and installation time
Benefits for the consultant
› Flexible configurations: multiple outdoor units can be positioned to make
the best use of the space available
› Outdoor units can be positioned up to m above or m below the indoor units
› The piping length can be up to m between the outdoor unit and
the furthest refrigeration cabinet or air conditioning indoor unit
› Suitable to indoor installations through the use of high ESP fans
Benefits for the end user
› Reduced energy consumption by up to % through heat recovery, together
with its optimised controls and inverter compressor technology
› Maximised retail sales space available as Conveni-Pack has a footprint up to
% smaller than conventional grocery refrigeration systems
› Quiet operation, thus ideal for densely populated urban areas.

Marketing tools
Download the selection software from the Extranet > Software Downloads > Refrigeration Xpress
Compact solution
› Small footprint
› Reduced piping requirements.
Flexible system for multiple applications
References
Edeka Buschkühle supermarket (Lippstadt, Germany)
The 2 Conveni-Pack systems supply 32 meters
of service counters, 12.5 meter convenience fridges, one cooling storage
room for fruit, an air curtain and 5 indoor units; the ZEAS system supplies
two deep-freeze cabinets with a total capacity of 5 kW.
› Connectable to all grocery refrigeration applications
and supplied with a wide range of air conditioning
indoor units to meet shop requirements.
› Ideal climate solution for small shops and petrol
stations.
Quiet in operation
› Improved acoustics thanks to night operation
mode, inverter control and inverter driven fans with
optimised blades and grills.
Internationally awarded
Since the introduction Conveni-Pack was recognized
as innovative and environmentally – proof of which
are the recent German and Irish award:
› Winner of  Institute of Refrigeration Ireland (IRI)
Environmental award
› Case: application of Carel controls to Daikin
Conveni-Pack refrigeration at a Tesco store
› Environmental Friendliness category of the Top
Retail Product Awards  in Germany.

406
Indoor units for connection to Conveni-Pack
To respond to all shop requirements for comfort cooling and heating, a wide range
of VRV indoor units and Biddle air curtains are available.
Capacity class (kW)
Model
Product name
Cooling capacity (kW)1
Heating capacity (kW)2
50
63
80
100
125
200
250
5.6
6.3
7.1
8.0
9.0
10.0
11.2
12.5
14.0
16.0
22.4
25.0
28.0
31.5
y
y
y
y
Round flow cassette
FXFQ-A
y
y
y
2-way blow
ceiling mounted cassette
FXCQ-A
y
y
y
Ceiling mounted
corner cassette
y
y
FXKQ-MA
Concealed ceiling unit
with inverter driven fan
FXSQ-P
y
y
y
y
y
Concealed ceiling unit
with inverter driven fan
FXMQ-P7
y
y
y
y
y
Large concealed
ceiling unit
FXMQ-MA
y
Ceiling suspended unit
FXHQ-A
4-way blow ceiling
suspended unit
FXUQ-A
Floor standing unit
FXLQ-P
y
y
Concealed
floor standing unit
FXNQ-P
y
y
y
y
Capacity class (kW)
Model
Product Name
Heating capacity (kW)2
80
100
125
140
200
250
7.4 - 9.2
11.6 - 13.4
15.6
16.2 - 19.9
29.4
29.4 - 31.1
Biddle air curtain
free hanging
CYVS-DK
y
y
y
y
y
y
Biddle air curtain cassette
CYVM-DK
y
y
y
y
y
y
Biddle air curtain recessed
CYVL-DK
y
y
y
y
y
y
1
2
3
Nominal cooling capacities are based on: indoor temperature: 27°CDB / 19°CWB, outdoor temperature: 35°CDB, piping length: 7.5m, level difference: 0m
Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB / 6°CWB, piping length: 7.5m, level difference: 0m
Optional

LRYEQ-AY1
Conveni-Pack refrigeration
system with heat recovery
Refrigeration solution for food retailers featuring award
winning technology for heat recovery
 Integrates high and low temperature refrigeration and air
conditioning (including heating) into one system
 Lower associated CO emissions thanks to the heat pump
technology
 The modularity of the Conveni-Pack system maximises installation
flexibility. Outdoor units can be grouped into blocks or rows, or
distributed around the building, to meet individual installation
constraints
 The heat extracted from the refrigeration showcases or
evaporators can be re-used for comfort heating of the shop at no
extra cost
 Low sound level including „night mode“ operation
Medium Temperature Refrigeration
Cooling capacity Air conditioning
Refrigeration (1)
Heating capacity (2) Air conditioning
Refrigeration (2)
Dimensions
Unit
LRYEQ-AY1
kW
kW
kW
kW
mm
mm
mm
kg
Nom.
Nom.
Nom.
Nom.
Height
Width
Depth
Weight
Heat exchanger
Compressor
Unit
Type
Type
Piston displacement
Speed
Output
Starting method
Frequency ON/OFF
Compressor 2
Speed
Output
Compressor 3
Speed
Output
Fan
Type
Quantity
Air flow rate
Cooling
Fan motor
Output
Drive
Sound pressure level Nom.
Operation range Evaporator
Cooling
Cooling
Ambient
Heating
Ambient
Refrigerant
Type
Charge
Control
Refrigerant oil
Type
Charged volume
Piping connections Refrigeration
Liquid
Gas
Power supply
Phase/Frequency/Voltage
m³/h
rpm
W
rpm
W
rpm
W
Nom.
Min.~Max.
Min.~Max.
Min.~Max.
m³/min
W
dBA
°CDB
°CDB
°CDB
kg
l
50m or less
50~130m
50m or less
50~130m
Hz/V
LRYEQAY
16
14.0
21.8
27.0
21.8
1,680
1,240
765
370
Cross fin coil
Hermetically sealed scroll compressor
13.34
6,300
2,500
Direct on line (inverter driven)
Less than 6 times/hour
2,900
3,600
2,900
4,500
Propeller fan
2
230
750
Direct drive
62.0
-20~10
-5~43
-15~21
R-410A
11.5
Electronic expansion valve
Daphne FVC68D
1.7 / 2.1 / 2.1 / 4.0
Ø 9.5 C1220T
Ø 12.7 C1220T
Ø 25.4 C1220T
Ø 28.6 C1220T
3~/50/380-415
() Cooling priority mode: evaporating temp. -°C; outdoor temp. °CDB; suction SH °C
() Heat recovery % mode: indoor temp. °CDB; outdoor temp. °CDB, °CWB; refrigeration load kW; piping length: .m; level difference: m

LCBKQ-AV1
Booster unit
 A booster unit allows to connect freezer showcases or cold rooms
to ZEAS and Conveni-Pack outdoor units
 Reduced piping requirements, from  to  pipes, compared to a
conventional system
 Low sound mode available reducing sound emissions significantly
without giving in on refrigeration capacity
LCBKQAV
Low Temperature Refrigeration
Cooling capacity Nom.
Dimensions
Unit
Weight
Compressor
Height
Width
Depth
LCBKQ-AV1
kW
mm
mm
mm
kg
Unit
Type
Piston displacement
m³/h
Number of revolutions
rpm
Output
W
Starting method
Frequency ON/OFF
Fan
Type
Air flow rate
Cooling Nom.
m³/min
°CDB
Operation range Evaporator
Cooling Min.~Max.
Ambient temperature Min.~Max.
°C
Refrigerant
Type
Control
Refrigerant oil
Type
Charged volume
l
Piping connections Piping length
System
Booster unit - IU
Power supply
Phase/Frequency/Voltage
Hz/V
3
3.35
480
680
310
47
Hermetically sealed swing compressor
10.16
6,540
1,300
Direct on line (inverter driven)
Less than 6 times/hour
Propeller fan
1.6
-45~-20
-15~43
R-410A
Electronic expansion valve
Daphne FVC50K + FVC68D
0.85 / 0.5
30m or less
1~/50/220-240
() Evaporating temp. -°C; outdoor temp. °C; suction SH K; saturated temp. to discharge pressure of booster unit -°C
409
JEHCCU-CM1/CM3
Condensing unit for commercial
refrigeration with reciprocating
technology
Refrigeration solution for small food retailers
 Designed specifically for small capacity refrigeration applications
in small food stores (eg. in bakeries and butchers), cold rooms,
bottle coolers and display cabinets
 Compact and lightweight for even the smallest of city centre
locations
 All components can be accessed, making maintenance quick and
easy
 Ideal for urban applications: sound proofing and low operating
sound levels mean the unit is quiet
 The optimised compressor range and increased condenser surface
deliver high levels of energy efficiency and reliability is ensured by
using high quality components and production processes
 Micro channel heat exchanger technology reduces the amount of
refrigerant used in the system, lowering environmental impact
Medium Temperature Refrigeration
JEHCCU-CM1/CM3
0050
Refrigerating capacity Medium
R-404A
Nom
kW
0.910
temperature
R-407C
Nom
kW
R-407F
Nom
kW
0.882
Medium temperature R-404A
Nom
kW
0.626
Power input
Dimensions
Unit
Height
mm
Width
mm
Depth
mm
Weight
Unit
kg
45
Compressor
Type
Model
AE4460Z-FZ1C
Piston displacement
m³/h
1.80
Oil
Charged volume
l
0.28
Oil Type
Fan
Air flow rate
Cooling Nom
m³/h
Sound pressure level Nom.
dBA
Piping connections Liquid line connection
inch
1/4“
Suction line connection
inch
3/8
Power supply
Phase/Frequency/Voltage
Hz/V
JEHCCU-CM/CM
0067
1.225
0100
1.495
1.187
0.763
1.449
0.927
0113
1.761
0140CM3
2.220
-*
607
876
420
54
CAJ9480Z
2.64
1.706
1.102
55
Reciprocating compressor
CAJ9510Z
CAJ9513Z
3.18
4.21
0.887
Uniqema Emkarate RL32CF
1,300
30
2.151
1.235
662
1,101
444
67.5
CAJ4517Z
TAJ4517Z
4.52
2,700
34
3/8“
1/2
1~/50/230
* values not yet available
() Refer to condition: Outside ambient temperature = °C, Evaporation temperature = -°C and K superheat (medium temperature application)

0140CM1
3~/50/400
JEHSCU-CM1/CM3
Condensing unit for commercial
refrigeration with scroll
technology
Refrigeration solution for small food retailers
 Designed specifically for small capacity refrigeration applications
in small food stores (eg. in bakeries and butchers), cold rooms,
bottle coolers and display cabinets
 Compact and lightweight for even the smallest of city centre
locations
 All components can be accessed, making maintenance quick and
easy
 Ideal for urban applications: sound proofing and low operating
sound levels mean the unit is quiet
 The optimised compressor range and increased condenser surface
deliver high levels of energy efficiency and reliability is ensured by
using high quality components and production processes
 Micro channel heat exchanger technology reduces the amount of
refrigerant used in the system, lowering environmental impact
JEHSCU-CM/CM
Medium Temperature Refrigeration
JEHSCU-CM1/CM3 0200CM1
0200CM3
0250CM1
0250CM3
0300CM1
0300CM3
0350CM3
Refrigerating
Medium
R-134a
Nom
kW
2.170
2.480
3.060
3.480
capacity
temperature
R-404A
Nom
kW
3.490
4.210
4.890
5.460
R-407C
Nom
kW
3.306
3.971
4.684
5.007
R-407F
Nom
kW
3.297
3.971
4.712
4.902
Power input
Medium
R-134a
Nom
kW
1.025
1.165
1.455
1.675
temperature
R-404A
Nom
kW
1.695
2.035
2.515
3.065
Dimensions
Unit
Height
mm
662
Width
mm
1,101
Depth
mm
444
Weight
Unit
kg
69.7
71.7
73.7
Compressor
Type
Scroll compressor
Model
ZB15KQE-PFJ ZB15KQE-TFD ZB19KQE-PFJ ZB19KQE-TFD ZB21KQE-PFJ ZB21KQE-TFD ZB26KQE-TFD
Piston displacement
m³/h
5.90
6.80
8.60
9.90
Oil
Charged volume
l
1.24
1.30
1.36
1.45
1.5
Polyester oil
Oil Type
Fan
Air flow rate
Cooling Nom
m³/h
2,700
Sound pressure level Nom.
dBA
33
36
40
Piping connections Liquid line connection
inch
3/8“
Suction line connection
inch
3/4
Power supply
Phase/Frequency/Voltage
Hz/V 1~/50/230
3~/50/400
1~/50/230
3~/50/400
1~/50/230
3~/50/400
() Refer to condition: Outside ambient temperature = °C, Evaporation temperature = -°C and K superheat (medium temperature application) () Sound pressure level is measured at m in anechoic room
411
JEHCCU-M3/L1/L3
JEHSCU-M3/L3
Condensing unit for commercial
refrigeration
Main benefits




Low operation sound level
Easy to install - fully equipped - packaged
Energy efficiency and performance
Robust and reliable design
Installer benefits
 Small, compact and robust for easy handling and installation in
limited space
 Fully factory tested and pre-wired electrical box for quick and easy
installation and commissioning
 Easy service thanks to very accessible components behind
removable robust panels
End-user benefits
Medium temperature
 Very quiet operation
 Strong anti-corrosion housing for long life, even in harsh
environmental conditions
 Trustworthy units, with proven component reliability and fully
qualified for the most demanding applications
 Reduced energy consumption, thanks to efficient compressors
and condenser fan speed control (except series )
 Fully packaged unit at a competitive price
6,672
8,017
8,897
9,756
3,934
4,546
5,680
6,153
6,201
7,620
8,452
9,268
JEHCCU0825M3 11,010
7,083
10,459
9,867
11,445
JEHCCU1000M3 13,528
8,667
12,851
13,038
14,126
3
JEHCCU0400M3
JEHCCU0500M3
JEHCCU0600M3
JEHCCU0675M3
5,766
7,137
7,660
8,930
Cooling
capacity
(W) a
R-407F
6,590
8,042
8,843
10,097
4
2
3
JEHCCU0075L1
JEHCCU0175L1
JEHCCU0175L3
JEHCCU0225L1
JEHCCU0225L3
JEHCCU0350L3
418
947
947
1,567
1,567
1,845
-
-
-
-
JEHCCU0400L3
2,824
-
-
-
-
JEHCCU0725L3
4,245
-
-
-
-
Medium Temperature
4
JEHCCU0825L3
5,818
-
-
-
-
JEHSCU0400M3
6,690
4,300
6,869
-
7,180
JEHSCU0500M3
8,050
5,150
8,275
-
8,700
JEHSCU0600M3
9,150
6,150
9,272
-
10,050
JEHSCU0680M3
9,850
6,928
10,744
-
11,192
JEHSCU0800M3 12,000
7,800
11,543
-
11,790
JEHSCU1000M3 14,200
3
4
9,900
14,630
-
15,075
JEHSCU0200L3
1,260
-
-
-
1,188
JEHSCU0300L3
1,645
-
1,701
-
1,615
JEHSCU0400L3
2,485
-
2,090
-
2,280
JEHSCU0500L3
3,000
-
2,632
-
2,774
JEHSCU0600L3
3,600
-
3,145
-
3,335
JEHSCU0750L3
4,320
-
-
-
-
JEHSCU1000L3
5,850
-
-
-
-
Low Temperature
2
3
O/Sg
Compressor
Cooling
capacity
(W) a
R-134a
Model
1
Low temperature
Performance
Cooling
Cooling
capacity
capacity
(W) a
(W) a
R-407A R-407C
Cooling
capacity
(W) a
R-404A
Series
4
Type
MTZ50-4VM
MTZ64-4VM
MTZ72-4VM
MTZ81-4VM
MTZ1004VM
MTZ1254VM
SC18CLX
NTZ48-5VM
NTZ48-4VM
NTZ68-5VM
NTZ68-4VM
NTZ96-4VM
NTZ1364VM
NTZ2154VM
NTZ2714VM
ZB29KQETFD
ZB38KQETFD
ZB45KQETFD
ZB48KQETFD
ZB58KCETFD
ZB76KCETFD
ZF06K4ETFD
ZF09K4ETFD
ZF13K4ETFD
ZF15K4ETFD
ZF18K4ETFD
ZF24K4ETWD
ZF33K4ETWD
Electrical Data
Oil
type
MFAb (A)
Airflow
Lock
m3/h
Rotor
current (A) R-404A R-134a R-407A R-407C R-407F
1.80
1.80
1.80
1.80
-
400V/3~/50Hz
400V/3~/50Hz
400V/3~/50Hz
Oil Bf
400V/3~/50Hz
48.5
64.0
80.0
80.0
29.80
3.90
-
400V/3~/50Hz
90.0
25
25
25
25
25
6770
14.0
1 1/8
1/2
1261 594 1435
205
62
37.49
3.90
-
400V/3~/50Hz 105.0
30
25
30
30
30
6770
14.0
1 1/8
1/2
1261 594 1435
205
62
3.08
8.40
8.40
11.80
11.80
16.70
0.60
0.95
0.95
0.95
0.95
1.80
230V/1~/50Hz
230V/1~/50Hz
400V/3~/50Hz
230V/1~/50Hz
400V/3~/50Hz
400V/3~/50Hz
20.0
37.0
16.0
53.0
25.0
32.0
15
15
15
20
15
15
-
15
15
15
20
15
15
-
15
15
15
20
15
15
1910
3040
3040
2620
2620
6050
1.2
4.6
4.6
4.6
4.6
7.6
3/8
5/8
5/8
5/8
5/8
7/8
1/4
3/8
3/8
3/8
3/8
1/2
884
1104
1104
1104
1104
1347
46
86
86
92
92
125
50
55
55
58
58
58
23.60
1.80
Oil Ae
0.50
0.50
0.50
0.50
0.60
Oil Bf
0.60
400V/3~/50Hz
51.0
15
-
15
-
15
6050
7.6
1 1/8
37.50
3.90
0.60
400V/3~/50Hz
74.0
25
-
25
-
25
6770
14.0
1 1/8
47.30
3.90
0.60
400V/3~/50Hz
96.0
25
-
25
-
25
6770
14.0
1 1/8
1/2
1261 594 1435
203
60
11.4
1.36
-
400V/3~/50Hz
50.0
15
15
15
-
15
6050
7.6
7/8
1/2
1347 556
884
121
54
14.4
2.07
-
400V/3~/50Hz
65.5
20
15
20
-
20
6050
7.6
7/8
1/2
1347 556
884
126
55
17.1
1.89
-
400V/3~/50Hz
74.0
20
15
20
-
20
5180
7.6
7/8
1/2
1347 556
884
128
60
18.8
1.80
-
400V/3~/50Hz 101.0
20
20
20
-
20
5180
7.6
7/8
1/2
1347 556
884
129
60
22.1
2.50
-
400V/3~/50Hz
95.0
25
20
25
-
25
6770
14.0
1 1/8
1/2
1261 594 1435
201
64
29.1
3.20
-
400V/3~/50Hz 118.0
35
25
35
-
35
6770
14.0
1 3/8
1/2
1261 594 1435
201
64
5.9
1.30
0.50
400V/3~/50Hz
26.0
15
-
15
-
15
2620
4.6
3/4
3/8
1108 478
650
94
47
8.0
1.50
0.50
400V/3~/50Hz
40.0
15
-
15
-
15
2620
4.6
3/4
3/8
1108 478
650
96
48
11.8
1.90
0.60
400V/3~/50Hz
51.5
15
-
15
-
15
6050
7.6
7/8
1/2
1347 556
884
129
55
14.5
1.90
0.60 Oil Bh 400V/3~/50Hz
64.0
15
-
15
-
15
6050
7.6
7/8
1/2
1347 556
884
130
56
15
20
20
20
15
20
20
20
6050
6050
5180
5180
Volume
(Liter)
Suction
(inch)
7.6
7.6
7.6
7.6
7/8
7/8
7/8
1 1/8
1/2
1/2
1/2
1/2
1347
1347
1347
1352
556
556
556
556
884
884
884
884
122
122
126
126
57
60
60
62
430
478
478
478
478
556
489
650
650
650
650
884
1/2
1352 556
884
130
58
1/2
1261 594 1435
203
61
1.90
0.60
400V/3~/50Hz
74.0
15
-
15
-
15
6050
7.6
7/8
1/2
1347 556
884
130
61
0.60
400V/3~/50Hz
99.0
20
-
20
-
20
6770
14.0
1 3/8
1/2
1261 594 1435
218
61
28.8
4.10
0.60
400V/3~/50Hz 127.0
30
-
30
-
30
6770
14.0
1 3/8
1/2
1261 594 1435
218
62
Oil A = Polyester oil (Emkarate RL32H)ww
f
Oil B = Polyester oil 160PZ
g
Oil A = Polyester oil (Copeland Ultra 22 CC, Copeland Ultra 32 CC, Copeland Ultra 32-3MAF, Mobil EALTM Arctic 22 CC, Uniqema Emkarate RL32CF)
h
Oil B = Mobil Arctic 22CC

15
20
20
20
4.10
e
Note: condensing units are pre-charged with oil as stated in table
15
20
20
20
17.1
Refer to condition: Outside ambient temperature= 32°C, Evaporation temperature = -10°C (medium temperature application); -35°C (low temperature application)
Sound pressure level measured in anechoic room
15
20
20
20
20.9
MFA = Maximum Fuse Amps
O/S = Oil Separator
Dimensions
14.90
18.94
21.04
23.63
Power
input
b
d
Sound
Weight pressure
(kg) dB(A) at
Width Depth Height
Liquid (inch)
1mc
(mm) (mm) (mm)
Connection
Oil Charge
Oil
(Liter) Charge (l)
a
c
Receiver
Swept
volume
(m³/h)
Largevariable
variable
capacity
condensing
Large
capacity
condensing
unit
unit
Condensing unit for
industrial refrigeration
Designed for outdoor use, the large condensing units
are a perfect medium to high capacity refrigeration
solution for cold stores, distribution platforms,
supermarkets, food processing, etc in low and
medium temperature applications.
These industrial condensing units are real workhorses
designed for maximum performance in minimum
space.
› High energy efficiency: inverter controlled
compressor, economizer, high performance
condenser
› Possibility of having a stand-by compressor
› Easy installation, ready to connect evaporators
› Integrated starter and control panel with electronic
controller
› Space saving construction due to the compact
design of the condenser coils arranged in a ‘W’
configuration
› Low sound operation
› Approved according to EN 378: 2008
(Safety and environmental requirements)
› Refrigerants: R-404A, R-134a, R-407C, R-507A
A comprehensive product range with 1 or
2 compressors and 4, 6, 8 or 10 condenser fans
› Chilled application:
R-404A | 113 - 417 kW
R-134a | 72.5 kW - 315.4 kW
R-407C | 100.3 kW - 430.2 kW
(at T0 = -10°C / Tamb = +32°C)
› Frozen application:
R-404A | 37 - 159 kW
(at T0 = -35°C / Tamb = +32°C)
From
To
Length
Width
Height
Weight
mm
2,240
4,940
mm
2,235
2,235
mm
2,340
2,340
kg
2,405
4,496
413
414
Control Systems
Control Systems
Options & Accessories
Individual control systems
Wired / infrared remote controls
Online controller
417
417
420
Centralised control systems
Centralised remote control /
Unified ON/OFF control / Schedule timer
422
Wireless room temperature sensor
Wired room temperature sensor
Other integration devices
436
436
436
437
422
423
423
Mini building management system
417
424
Standard protocol interfaces
Modbus interface
KNX Interface
BACnet Interface
LonWorks Interface
417
426
430
431
432
Daikin Configuration Software
EKPCCAB3
433
433
Remote monitoring and maintenance
ACNSS
434
415
Controllers
ONLINE
CONTROLLER
WIRED REMOTE CONTROL
BRC1E52A
INTELLIGENT
TOUCH MANAGER
DCM601A51
INFRARED REMOTE
CONTROLLER
416
Individual control systems
BRC1D52
BRC944B2
ARC466A1
BRC4*/BRC7*
BRC944B2*/BRC1D52
ARC4*/BRC4*/BRC7*
Wired remote control
Infrared remote control
› Schedule timer:
Operation buttons: ON / OFF, timer mode start / stop, timer mode
on / off, programme time, temperature setting, air flow direction (1),
operating mode, fan speed control, filter sign reset (2), inspection
(2)/ test indication (2)
Display: Operating mode, battery change, set temperature, air
flow direction (1), programmed time, fan speed, inspection / test
operation (2)
Five day actions can be set as follows:
- set point: unit is switched ON and normal
operation is maintained
- OFF: unit is switched OFF1
- limits: unit is switched ON and min./max. control
(cf. limit operation for more details)
› Home leave (frost protection): during absence,
the indoor temperature can be maintained at a certain level.
This function can also switch the unit ON/OFF
› User friendly HRV function, thanks to the introduction
of a button for ventilation mode and fan speed
› Constantly monitoring of the system for malfunctions
in a total of 80 components
› Immediate display of fault location and condition
› Reduction of maintenance time and costs
1. Not applicable for FXDQ, FXSQ, FXNQ, FBDQ, FDXS, FBQ
2. For FX** units only
3. For all features of the remote control, refer to the operation manual
Display
›
›
›
›
›
›
›
›
›
›
›
›
›
1
Operating mode1
Heat Recovery Ventilation (HRV) in operation
Cool / heat changeover control
Centralised control indication
Group control indication
Set temperature1
Air flow direction1
Programmed time
Inspection test / operation
Fan speed1
Clean air filter
Defrost / hot start
Malfunction
Only functions marked with ‘1’ are available on BRC944B2
BRC2E52A / BRC3E52A
NEW
Simplified wired remote control developed for hotel applications
›
›
›
›
Symbol driven interface for intuitive control
Functions restricted to basic customer needs
Contemporary design
Energy saving thanks key card,
window contact integration and set point limitation
› Flexible setback function ensures room temperature remains
within comfortable limits to ensure guest comfort
› Flat backpanel for easy installation
› Easy commissioning: intuitive interface
for advanced menu settings
› 2 versions available:
r Heat pump type: temperature,
fan speed, ON/OFF
r Heat recovery type: temperature,
mode, fan speed, ON/OFF
› Replaces existing BRC2C51 & BRC3A61
417
Individual control systems
User friendly remote control with
contemporary design
BRC1E52A/B
A series of energy saving functions that
can be individually selected
Graphical display of indicative
› Temperature range limit
› Setback function
› Presence & floor sensor connection
(available on new round flow cassette)
› kWh indication
› Set temperature auto reset
› Off timer
electricity consumption
(Function available in
combination with FCQG and
FCGHQ)
Temperature range limit avoids excessive
heating or cooling
Save energy by constraining the lower temperature
limit in cooling and upper temperature limit in
heating mode.
note : Also available in auto cooling/heating change over mode.
Other functions
› Up to 3 independent schedules can be set,
so the user can easily change the schedule himself
throughout the year (e.g. Summer, winter, mid-season)
› Possibility to individually restrict menu functions
Easy to use: all main functions directly accessible
› Easy setup: clear graphical user interface for
advanced menu settings
› Real time clock with auto update to daylight
saving time
› Built-in backup power: when a power failure occurs
all settings remain stored up to 48 hours
› Supports multiple languages
English, German, Dutch, Spanish, Italian, Portuguese,
French, Greek, Russian, Turkish, Polish (BRC1E52A)
English, German, Czech, Croatian, Hungarian,
Romanian, Slovenian, Bulgarian, Slovak, Serbian,
Albanian (BRC1E52B)
kWh indication keeps track of your
consumption
The kWh indication shows an indicative electricity
consumption of the last day/month/year.
Daikin Altherma low temperature wired remote control
EKRUCBL1-7
The Daikin Altherma low temperature is equipped
with an advanced user interface.
Commissioning, servicing and day-to-day operation
become straightforward.
The multi-lingual and graphical interface provides
full-text representation, easy menu navigation and
intelligent control features
418
› Self-explanatory controller for easy and quick
commissioning
› Possibility of preparing and uploading field settings
via a PC
› Feedback on operation conditions and energy
consumption
Individual control systems
Siesta individual control systems
ARCWLA / ARCWB
Overview controllers for Siesta Sky Air
Siesta Sky Air indoor units
Controllers
ACQ-D 4-way blow, ceiling mounted cassette
t Standard infrared remote control (ARCWLA) in box of decoration panel ADP125A
t Optional wired remote control ARCWB
t Optional group controller R04084124324
AHQ-C ceiling suspended
t Standard infrared remote control in box of indoor unit ARCWLA
t Optional wired remote control ARCWB
t Optional group controller R04084124324
ABQ-C concealed ceiling
t Standard wired remote control (ARCWB) in box of indoor unit
t Optional group controller R04084124324
Overview of features
Feature
ARCWB
Option for AHQ-C and ACQ-D
Standard for ABQ-C
1
ON/OFF switch
Standard
Default range 16-30°C
2
Temperature setting
Optional range 20-30°C
Switch between °C and °F
Standard
By dipswitch selection
Standard
3
Room temperature sensor on remote control
4
Cool / Fan dry / Heat / Auto
Standard
5
Sleep mode
Standard
6
Fan Speed selection
7
Delay timer
8
7-days programmable timer
9
Real time clock display
10
Air swing selection
Standard
Standard
1, 2 & 4 hours delay
Standard
Standard
ON/OFF swing mode
Standard
Change swing option
(draft/soil prevention or standard)
Standard
11
LCD display without backlight
12
Key lock
Standard
Standard
13
Error code indication
Standard
14
IR receiver to enable compatibility with infrared remote control
(disabled when lock function is activated)
Standard
15
Last state memory from indoor PCB
16
Silent mode
By dipswitch selection
Standard
By dipswitch selection
17
Turbo mode
18
Compressor test model (compressor force ON)
Standard
19
Daikin inverter error code
Standard
20
UART communication port (for Daikin protocol)
Standard
21
Backup battery
Standard
Specifications
› Dimensions (length x width x height) ARCWB: 0.15 m x 0.21 m x 0.04 m.
› ARCWB comes standard with a 10 meter wire, which can be extended to maximum wire length of 15 meter. ARCWB can only control one
indoor unit at a time; group control is only possible when using option R04084124324.
419
Individual control systems
Online controller
BRP069A41/42
Always in control,
no matter where you are
The plug-and-play Online Controller allows you to set
and even schedule the temperature from anywhere
using Apple or Android systems. So you can manage
the unit when away from home, offering optimal
climate control while saving energy.
1
WLAN adaptor
2
Smartphone
3
Tablet
With the Daikin Online Controller application in
combination with the plug-and-play wireless LAN
device and an active internet connection, you can
manage your unit from anywhere, offering optimal
climate control while saving energy.
The Daikin Online Controller application can control
and monitor the status of up to 50 units and allows
you to:
› Monitor the status of your heat pump unit
› Control the operation mode, set temperature,
air flow rate and direction
› Schedule the set temperature and operation mode
with up to  actions per day for  days
420
Individual control systems
Connectable indoor units
Features Online Controller
BRP069A41
BRP069A42
› FTXG-LW/S
› FTXJ-LW/S
› FTXZ-N
(available January ‘)
› FTXS-K
› FTXM-K
› FTXS-G
› ATXS-K
› FTX-J
› FTX-GV
› FTX-K
›
›
›
›
›
›
›
ATX-J
FVXG-K
FVXS-K
FLXS-B
FTXLS-K
FTXL-JV
ATXL-JV
The Daikin online controller can manage your unit in several ways.
You can operate it in-home by connecting your smartphone to a private wireless
network or out-of-home by connecting your smartphone to a mobile network
(e.g. 3G) or an external wireless network.
Connection
Operation modes
Temperature
Weekly schedule timer
Fan
General information
Between WLAN adaptor & indoor
unit via S21 connector
Start
Stop
Automatic
Cooling
Heating
Dry
Fan Only
Set point adjustment
Start/stop operation
Select operation mode
Set temperatures set point
4 actions per day (max. 28 actions)
Set air flow
Set air flow direction
Current room temperature
Current outdoor temperature
Remote adapter software updates
Mulit-language interface
Automatic time update (daylight saving time)
Demo function
BRP069A41
BRP069A42
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y (if unit is turned on)
y
y
y
y
421
Centralised control systems
Centralised control of the Sky Air and VRV system can be achieved via 3 user friendly compact.
These controls may be used independently or in combination with 1 group = several (up to 16)
indoor units in combination and 1 zone = several groups in combination.
A centralised remote control is ideal for use in tenanted commercial buildings subject to random occupation,
enabling indoor units to be classified in groups per tenant (zoning).
The schedule timer programmes the schedule and operation conditions for each tenant and the control can
easily be reset according to varying requirements.
DCS302C51
Centralised remote control
Providing individual control of  groups (zones) of indoor units.
 a maximum of  groups ( indoor units, max.  outdoor units)
can be controlled
 a maximum of  groups ( indoor units, max.  outdoor units)
can be controlled via  centralised remote controls in separate
locations
 zone control
 group control
 malfunction code display
 maximum wiring length of ,m (total: ,m)
 air flow direction and air flow rate of HRV can be controlled
 expanded timer function
DCS301B51
Unified ON/OFF control
Providing simultaneous and individual control of 16 groups
of indoor units.





a maximum of  groups ( indoor units) can be controlled
 remote controls in separate locations can be used
operating status indication (normal operation, alarm)
centralised control indication
maximum wiring length of ,m (total: ,m)
DST301B51
Schedule timer
Enabling 64 groups to be programmed.




422
a maximum of  indoor units can be controlled
 types of weekly schedule
a maximum of  hours back up power supply
a maximum wiring length of ,m (total: ,m)
Centralised control systems
DTA113B51
Basic solution for control of Sky Air and VRV
 Rotation function
 Backup operation function.
DS-NET adapter - DTAB
BRCD
Up to  units /  adapter
DCS601C51
Detailed & easy monitoring and operation of VRV systems (max. 64 indoor units groups).
third party controller (domotics, BMS, etc.)
Public line
Fire alarm
Onboard
modem
Ethernet
Forced OFF contact input
Air conditioning
Network Service
System
DIII-NET
Indoor units
HRV
DCSC
Languages
 English
 French
 German
 Italian
 Spanish
 Dutch
 Portuguese
System layout
 Up to  indoor units can be
controlled
 Touch panel (full colour LCD
via icon display)
Management
 Easy management of
electricity consumption
 Enhanced history function
Control
 Individual control
(set point, start/stop,
fan speed)
(max.  groups/indoor units)
 Set back shedule
 Enhanced scheduling function
( schedules,  patterns)
 Flexible grouping in zones
 Yearly schedule
 Fire emergency stop control
 Interlocking control
 Increased HRV monitoring and
control function
 Automatic cooling / heating
change-over
 Heating optimization
 Temperature limit
 Password security:  levels
(general, administration
& service)
 Quick selection and full
control
 Simple navigation
Monitoring
 Visualisation via Graphical User
Interface (GUI)
 Icon colour display change
function
 Indoor units operation mode
 Indication filter replacement
 Multi PC
Cost performance
 Free cooling function
 Labour saving
 Easy installation
 Compact design: limited
installation space
 Overall energy saving
Open interface
 Communication to any third
party controller (domotics,
BMS, etc.) is possible via open
interface (http option)
Connectable to
 VRV
 HRV
 Sky Air
 Split (via interface adapter)
423
NEW
Mini Building Management System
DCM601A51
Mini BMS
r Price competitive mini BMS
r Cross-pillar integration of Daikin products
r Integration of third party equipment
with full integration
across all product pillars
System overview
Web Access
Internet
Extranet
LAN
3G
http interface
Integration of third
party equiqment
Full control of Daikin
HVAC-R portfolio
DCM601A51
ITM plus adaptor line
Max. 7
adapters
Di/Pi line
Fire alarm
Max. 200m
DCM601A52
Di/Pi port
kWh meter
Direct plug & play connection!
indoor units,
air curtain,
Lighting
Fan
Pump
Sensor
Multi state objects
Elevator
424
Air handling unit
Alarm
I/O module
I/O module
hydrobox,
air handling units
Referigeration
WAGO
interface
Chillers and AHU
BACnet
protocol
Fan coil units
Split
Mini Building Management System NEW
User friendliness
› Intuitive user interface
› Visual lay out view and direct access to indoor unit
main funtions
› All functions direct accessible via touch screen
or via web interface
Smart energy management
› Monitoring if energy use is according to plan
› Helps to detect origins of energy waste
› Powerful schedules guarantee correct operation
throughout the year
› Save energy by interlocking A/C operation with other
equiment such as heating
Flexibility
Plug & play
NEW › Cross-pillar integration (heating, air conditioning,
applied systems, refrigeration, air handling units)
NEW › BACnet protocol for 3rd party products integration
› I/O for integration of equipment such as lights,
pumps… on WAGO modules
› Modular concept for small to large applications
› Control up to 2,560 indoor unit groups
Split
Fan coils
Chillers and AHU
Refrigeration
Easy servicing and commissioning
› Remote refrigerant containment check preventing
on site visit
› Simplified troubleshooting
› Save time on commissioning
thanks to the pre-commissioning tool
› Auto registration of indoor units
Flexibility in size
64 up to 2,560 groups
Functions overview
Languages
Management
Control
› English
› Web access
› Individual control
› French
› Power Proportional
› German
› Italian
› Spanish
› Dutch
› Portuguese
Distribution (option)
› Operational history
(malfunctions, operation hours, …)
› Schedule setting (Weekly
- Chillers (via POL638.70 controller)
NEW
- Daikin AHU
schedule, yearly calender,
- Fan coils
seasonal schedule)
- Daikin Altherma Flex type
- LT and HT hydroboxes
- monitor if energy use is
› Setpoint limitation
- Air curtains
according to plan
› Temperature limit
- detect origins of energy
› Up to 2,560 unit groups can
waste
be controlled
› Setback function
(ITM plus Integrator + 7 iPU
› Sliding temperature
› Ethernet TCPIP
- DX Split, Sky Air, VRV
(2,560 groups)
› Interlock control
› Smart energy management
System layout
(incl. iTM adaptor)
Connectable to
- WAGO I/O
NEW
- BACnet protocol
WAGO Interface
› Modular integration of 3rd
party equipment
- WAGO coupler (interface
between WAGO and Modbus)
- Di module
- Do module
- Ai module
- Thermistor module
425
Standard protocol interfaces
Modbus Interface
RTD
RTD-RA
› Modbus interface for monitoring and control
of residential indoor units
RTD-NET
› Modbus interface for monitoring and control
of Sky Air, VRV, VAM and VKM
RTD-10
› Advanced integration into BMS of Sky Air, VRV,
VAM and VKM through either:
- Modbus
- Voltage (-V)
- Resistance
› Duty/standby function for server rooms
RTD-LT/CA
› Modbus interface for monitoring and
control of Daikin Altherma low temperature
(EHVH(X)-C / EHBH(X)-C)
› Voltage and resistance control
› Photovoltaic operation signal for energy saving
RTD-20
› Advanced control of Sky Air, VRV, VAM/VKM
and air curtains
› Clone or independent zone control
› Increased comfort with integration of CO sensor
for fresh air volume control
› Save on runningcosts via
- pre/post and trade mode
- set point limitation
- overall shut down
- PIR sensor for adaptive deadband
RTD-HO
› Modbus interface for monitoring and control of
Sky Air, VRV, VAM and VKM
› Intelligent hotel room controller
RTD-W
› Modbus interface for monitoring and control of
Daikin Altherma Flex Type, VRV HT hydrobox and
small inverter chiller

Integration of RA, Sky Air,
VRV, Daikin Altherma Flex,
small inverter chiller and small
inverter chiller in BMS or home
automation systems
Overview functions
Main functions
RTD-RA
Dimensions
HxWxD
mm
Key card + window contact
Set back function
Prohibit or restrict remote control functions (setpoint limitation, ...)
Modbus (RS)
Group control
 -  V control
Resistance control
IT application
Heating interlock
Output signal (on/defrost, error)
Retail application
Partitioned room control
Air curtain
RTD-NET
RTD-10
80 x 80 x 37,5
RTD-20
RTD-HO
100 x100 x 22
3
3
3
3(1)
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3**
3
3
3
3
3***
3***
3
3****
3
3
3
3
(): By combining RTD-RA devices
Control functions
RTD-RA
RTD-NET
RTD-10
RTD-20
RTD-HO
On/Off
Set point
Mode
fan
Louver
HRV Damper control
Prohibit/Restrict functions
Forced thermo off
M,C
M
M
M
M
M
M
M
M
M
M
M
M,V,R
M,V,R
M,V,R
M,V,R
M,V,R
M,V,R
M,V,R
M
M
M
M
M
M
M
M*
M*
M*
M*
M*
RTD-RA
RTD-NET
RTD-10
RTD-20
RTD-HO
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
Monitoring functions
On/Off
Set point
Mode
fan
Louver
RC temperature
RC mode
nbr units
Fault
Fault code
Return air temperature (Average /Min/Max)
Filter alarm
Termo on
Defrost
Coil In/Out temperature
M
M
M
M
M
Main functions
Dimensions
On/off prohibition
Modbus RS485
Dry contact control
Output signal (operation error)
Space heating / cooling operation
Domestic hot water control
Smart Grid control
RTD-W
HxWxD
mm
M*
RTD-LT/CA
100x100x22
3
3
3
3
3
3
3
3
3
3
3
3
3
M,C
M,V
M
M
M,C,V
M,R,V
M
M
M,C,V
M,C
M,R,V
Control functions
On/Off Space heating/cooling
Set point leaving water temperature (heating / cooling)
Room temperature setpoint
Operation mode
Domestic Hot water ON
Domestic Hot Water reheat
Domestic Hot Water reheat setpoint
Domestic Hot Water storage
Domestic Hot Water Booster setpoint
Quiet mode
Weather dependent setpoint enable
Weather dependent curve shift
Fault/pump info relay choice
Control source prohibition
M,C
M
M,C
M
M
M
M
M,C
M
M
R
M
Smart grid mode control
Prohibit Space heating/cooling
Prohibit DHW
Prohibit Electric heaters
Prohibit All operation
PV available for storage
Powerful boost
C
C
C
C
C
C
Monitoring functions
On/Off Space heating/cooling
Set point leaving water temperature (H/C)
Room temperature setpoint
Operation mode
Domestic Hot Water reheat
Domestic Hot Water storage
Number of units in the group
Average leaving water temperature
Remocon room temperature
Fault
Fault code
Circulation pump operation
Flow rate
Solar pump operation
Compressor status
Desinfection operation
Setback operation
Defrost/ start up
Hot start
Booster Heater operation
3-Way valve status
Pump running hours accumulated
Compressor running hours accumulated
Actual leaving water temperature
Actual return water temperature
Actual DHW tank temperature (*)
Actual refrigerant temperature
Actual outdoor temperature
M,C
M
M
M
M
M
M
M
M
M,C
M
M
M
M
M
M
M
M
M
M
M
M,C
M
M
M
M
M
M
M
M,C
M
M,C
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M : Modbus / R : Resistance / V : Voltage / C: control
* : only when room is occupied / ** : setpoint limitation / (*) if available
*** : no fan speed control on the CYV air curtain / **** : run & fault

Standard protocol interfaces
DIII-net Modbus interface
EKMBDXA
Integrated control system for seamless connection between
Sky Air and VRV and BMS systems
›
›
›
›
Communication via Modbus RS485 protocol
Detailed monitoring and control of the VRV total solution
Easy and fast installation via DIII-net protocol
As the Daikin DIII-net protocol is used only one modbus interface is needed per Daikin
VRV network
DIII- NET
EKMBDXA
VRV Outdoor unit
HRV
up to 256 units connectable per interface
Sky Air network
EKMBDXA
Building
control
network
Fire alarm
Security
Power supply facility
Maximum number of connectable indoor units
Maximum number of connectable outdoor units
Communication
DIII-NET - Remark
Protocol - Remark
Protocol - Type
Protocol - Max. Wiring length
Dimensions
HeightxWidthxDepth
Weight
Ambient temperature - operation
Max.
Min.
Installation
Power supply
Frequency
Voltage
428
m
mm
kg
°C
°C
Hz
V
Lighting
Pump
Elevator
EKMBDXA7V1
64
10
DIII-NET (F1F2)
2 wire; communication speed: 9600 bps or 19200 bps
RS485 (modbus)
500
124x379x87
2.1
60
0
Indoor installation
50
220-240
Standard protocol interfaces
Modbus interface
Integrate chillers, fan coil units and air handling units in BMS systems via modbus protocol
Serial card RS/Modbus
Serial sequencing panel
EKCMJ
EKCMJ
EKCMJ
EKACJ
EKDSSP-S
D-AHU
Climatix
MODBUS
EKCMJ
MicroTech III
()
FWM-D/FWS-A
FWL-D/FWR-A
MicroTech III
MicroTech III
FWV-D/FWZ-A
FWECA () / FWECA ()
EKFCMBCB
FWC-BT/BF
FWF-BT/BF
Building
control
network
Fire alarm
Security
() The communication module is integrated in the controller
Power supply facility
() Connection to FWV-D, FWL-D & FWM-D
Lighting
Pump
Elevator
() Connection to FWV-D, FWL-D, FWM-D and to FWZ-A, FWR-A, FWS-A
Integrate Refrigeration units in BMS systems via modbus protocol
DIII net
Daikin Modbus
Communication Interface
BRRAV
Monitoring system
rd party equipment
Conveni-pack
ZEAS
Multi-ZEAS
Daikin indoor units and
Biddle air curtains
Booster unit
Booster unit
* For all connectable indoor units and Biddle air curtains please refer to the Conveni-pack pages in this catalogue
429
Standard protocol interfaces
KNX interface
KLIC-DD
KLIC-DI
Integration of Split, Sky Air and VRV in HA/BMS systems
Connect split indoor units to KNX interface
for Home Automation system
Concept
light
house
Domotica
shutter control
Controller
Interface Daikin protocol/ KNX
tv
Connect Sky Air / VRV indoor units to
KNX interface for BMS integration
Concept
light
shop
shutter control
Domotica
tv
Controller
Interface Daikin protocol/ KNX
KNX interface line-up
The integration of Daikin indoor units through
the KNX interface allows monitoring and control
of several devices, such as lights and shutters, from
one central controller. One particularly important
feature is the ability to programme a ‘scenario’
- such as “Home leave” - in which the end-user selects
a range of commands to be executed simultaneously
once the scenario is selected. For instance in
“Home leave” , the air conditioner is off, the lights are
turned off, the shutters are closed and the alarm is on.
KNX interface for
KLIC-DD Size 45x45x15mm
Split
Basic control
On/Off
Mode
Temperature
Fan speed levels
Swing
Advanced functionalities
Error management
Scenes
Auto switch off
Temperature limitation
Initial configuration
Master and slave configuration
430
Sky Air
KLIC-DI Size 90x60x35mm
VRV
t
t
t
Auto, heat, dry, fan, cool
Auto, heat, dry, fan, cool
Auto, heat, dry, fan, cool
t
3 or 5 + auto
Stop or movement
t
2 or 3
Stop or movement
t
2 or 3
Swing or fixed positions (5)
Communication errors, Daikin unit errors
t
t
t
t
t
t
t
t
t
t
t
t
t
t
Standard protocol interfaces
BACnet Interface
Integrated control system for seamless connection between VRV,
applied systems, air handling units and BMS systems
BMS
 Interface for BMS system
 Communication via BACnet protocol
(connection via Ethernet)
 Unlimited sitesize
 Easy and fast installation
 PPD data is available
on BMS system (only for VRV)
VRV network
BACNET / ETHERNET
DIII- NET
DMSA
Local Control
VRV Outdoor unit
HRV
up to  units connectable per interface
Remote Control
Applied systems network
Serial Card
BACnet MSTP
EKACBACMSTP
Serial sequencing
panel
EKCMJ
EKCMJ
EKCMJ
EKDSSP-S
Air handling unit network
EKCMBACIP
EKCMBACMSTP
Fire alarm
Security
Pump
Lighting
Power supply facility
Building
control
network
Elevator
431
Standard protocol interfaces
LonWorks Interface
Open network integration of VRV and applied systems
monitoring and control functions into LonWorks networks
LON BMS
VRV network
LonTalk
DIII- NET
adapter
ETHERNET (TCP/IP)
 Interface for Lon connection to
LonWorks networks
 Communication via Lon protocol
(twisted pair wire)
 Unlimited sitesize
 Quick and easy installation
DMSB
Local Control
VRV
Outdoor
unit
HRV
up to  units connectable per interface
Remote Control
Applied systems network
Serial card
LON FTT 
LonTalk
adapter
EKACLONP
Serial sequencing
panel
EKDSSP-S
LonTalk
adapter
LonPoint
LonPoint
Security
Fire alarm
Building
control
network
System
432
EKCMJ
EKCMJ
EKCMJ
Daikin Configurator Software
Daikin Configurator Software
EKPCCAB3
Simplified commissioning:
graphical interface to configure, commission
and upload system settings
Simplified commissioning
The Daikin configurator for Daikin Altherma and
VRV is an advanced software solution that allows for
easy system configuration and commissioning:
› Less time is required on the roof configuring
the outdoor unit
› Multiple systems at different sites can be managed
in exactly the same way, thus offering simplified
commissioning for key accounts
› Initial settings on the outdoor unit can be easily
retrieved
Simplified
Retrieve initial
commissioning
system settings
433
Remote monitoring and maintenance
ACNSS
Air Conditioning
Network Service
System
The challenge of your technical management is
safeguarding in the long term optimal operation
of your air conditioning system without incurring
huge costs along the way. Daikin's Air Conditioning
Network Service System improves the effectiveness
of your management.
Data
The network service system is a link via the internet,
between the air conditioning system and Daikin's
Remote Monitoring Centre. In so doing, expert
service engineers monitor the operating status of
the entire system nonstop all through the year.
The 'ACNSS monitoring service' prevents troubles and
prolongs the life of your equipment.
Thanks to the prediction of malfunctions and the
technical advise following from data analysis, you
not only maximise equipment availability, but also
control cost without sacrificing comfort levels.
Daikin's ACNSS is also supported by the optional
'ACNSS energy saving service' as energy use is one
of the largest operating expenses of any business.
This service enables you to optimise on power
consumption without failing to keep the customer's
amenity.
WWW.
434
Remote monitoring and maintenance
ACNSS monitoring
service
ACNSS energy saving
service
Comfort maintained
1 Data transmission
2 Daikin Remote Monitoring Centre
Air conditioners's running information and
other necessary data are collected and compiled,
and sent to the centre. Advance failure forecasts
and monitoring data for accidental problems are
transmitted.
Daikin's control implemented
OPTION:
energy-saving control
determination
Operating information is analyzed,
and the optimum energy-saving
control settings are calculated
according to weather data for
the region.
Weather
information
Information to customers,
service company
3 data analysis & system monitoring
Reporting data is reviewed and system is monitored
24/7 for any occurances.
Energy-saving Report
Maintenance Report
Malfunction and prediction call
* A contract with Daikin is necessary for applying Energy-saving Air conditioning Network Service System. If you would like an estimation, please contact us.
* Contact your Daikin responsible for connectable units
435
Room sensors
Wireless room temperature sensor
K.RSS
Flexible and easy installation
› Accurate temperature measurement thanks to flexible
placement of the sensor
› No need for wiring
› No need to drill holes
› Ideal for refurbishment
Connection diagram Daikin indoor unit PCB (FXSQ-P example)
Power supply – X, X
Air sensor – XA, X
Rf Receiver
RF sender
Specifications
Dimensions
Weight
Power supply
Battery life
Battery type
Maximum range
Operation range
Communication
mm
g
m
°C
Type
Frequency
MHz
Wireless room temperature sensor kit (K.RSS)
Wireless room temperature receiver
Wireless room temperature sensor
50 x 50
ø 75
40
60
16VDC, max. 20 mA
N/A
N/A
+/- 3 years
N/A
3 Volt Lithium battery
10
0~50
RF
868.3
› Room temperature is sent to the indoor unit every  seconds or if the temperature difference is .°C or larger.
Wired room temperature sensor
KRCS01-1B
KRCS01-4B
› Accurate temperature measurement,
thanks to flexible placement of the sensor
Specifications
Dimensions (HxW)
Weight
Length of branch wiring
436
mm
g
m
60 x 50
300
12
Other integration devices
ADAPTER PCBs
Simple solutions for unique requirements
Daikin’s adapter PCBs provide simple solutions
for unique requirements. They are a low cost option
to satisfy simple control requirements and can be
used on single or multiple units.
(E)KRP1B*
adapter for wiring
t Facilitates integration of auxiliary heating apparatus, humidifiers, fans, damper
t Powered by and installed at the indoor unit
KRP2A*/KRP4A*
Wiring adapter for
electrical appendices
t
t
t
t
DTA104A*
Outdoor Unit External
Control Adapter
t Individual or simultaneous control of VRV system operating mode
t Demand control of individual or multiple systems
t Low noise option for individual or multiple systems
Remotely start and stop up to 16 indoor units (1 group) (KRP2A* via P1 P2)
Remotely start and stop up to 128 indoor units (64 groups) (KRP4A* via F1 F2)
Alarm indication/ fire shut down
Remote temperature setpoint adjustment
KRP928*
Interface adapter for
DIII-net
KRP413*
Wiring adapter normal
open contact / normal
open pulse contact
KRP980*
Adapter for split units
without an S21 port
t Allows integration of split units to Daikin central controls
t
t
t
t
t
Switch off auto restart after power failure
Indication of operation mode / error
Remotely start /stop
Remotely change operation mode
Remotely change fan speed
t Connect a wired remote control
t Connect to Daikin central controls
t Allow external contact
Concept and benefits
› Low cost option to satisfy simple control requirements
› Deployed on single or multiple units
Options & accessories
AUTOCLEANING PANEL
FILTERS
INTELLIGENT SENSORS
438
Options &
accessories
Heating
Split
Sky Air
VRV
Ventilation and hot water
Chillers
Fan coil units
Air handling units
Refrigeration
Control Systems
440
442
444
448
454
456
462
464
466
467
439
Options - Heating
Daikin Altherma hybrid heat pump
Remote user interface (DE, FR, NL, IT)
Remote user interface (EN, SV, NO, FI)
Remote user interface (EN, ES, EL, PT)
Remote user interface (EN, TR, PL, RO)
Remote user interface (DE, CS, SL, SK)
Remote user interface (EN, HR, HU, BG)
Remote user interface (EN, DE, RU, DA)
Propane set
Concentric connection Ø 80/125
Eccentric connnection Ø 80
Cover plate 35
Installation jig
Drain pan for reversible H/B
Thermistor recirculator
Roof Terminal PP/GLV 60/100 AR460
Weather Slate Steep Pb/GLV 60/100 18°-22°
Weather Slate Steep Pb/GLV 60/100 23°-27°
Weather Slate Steep PF 60/100 25°-45°
Weather Slate Steep Pb/GLV 60/100 43°-47°
Weather Slate Steep Pb/GLV 60/100 48°-52°
Weather Slate Steep Pb/GLV 60/100 53°-57°
Weather Slate Flat Alu 60/100 0°-15°
Weather Slate Flat Alu 60/100
Wall Terminal Kit PP/GLV 60/100
Wall Terminal Kit low profile PP/GLV 60/100
Extension PP/GLV 60/100 x 500mm
Extension PP/GLV 60/100 x 1000mm
Elbow PP/GLV 60/100 30°
Elbow PP/GLV 60/100 45°
Elbow PP/GLV 60/100 90°
Meas. Tee with Inspection Panel PP/GLV 60/100
Wall Bracket Dn.100
Wall Terminal Kit PP/GLV 60/100
Wall Terminal Kit low profile PP/GLV 60/100
Plume Managment Kit 60 UK Only
Flue Deflector 60 UK Only
PMK Elbow 60 90 UK Only
PMK Elbow 60 45° (2 pcs) UK Only
PMK Extension 60 L=1000 incl. breaket UK Only
Roof Terminal PP/GLV 80/125 AR300 Ral-9011
Weather Slate Steep Pb/GLV 80/125 18°-22°
Weather Slate Steep Pb/GLV 80/125 23°-27°
EKRUCBL1
EKRUCBL2
EKRUCBL3
EKRUCBL4
EKRUCBL5
EKRUCBL6
EKRUCBL7
EKHY075787
EKHY090717
EKHY090707
EKHY093467
EKHYMNT1
EKHYDP1
EKTH2
EKFGP6837
EKFGS0518
EKFGS0519
EKFGP7910
EKFGS0523
EKFGS0524
EKFGS0525
EKFGP1296
EKFGP6940
EKFGP2978
EKFGP2977
EKFGP4651
EKFGP4652
EKFGP4664
EKFGP4661
EKFGP4660
EKFGP4667
EKFGP4631
EKFGP1292
EKFGP1293
EKFGP1294
EKFGP1295
EKFGP1284
EKFGP1285
EKFGP1286
EKFGP6864
EKFGT6300
EKFGT6301
Daikin Altherma ground source heat pump
Ground source filling kit
Remote user interface (DE, FR, NL, IT)
Remote user interface (EN, SV, NO, FI)
Remote user interface (EN, ES, EL, PT)
Remote user interface (EN, TR, PL, RO)
Remote user interface (DE, CS, SL, SK)
Remote user interface (EN, HR, HU, BG)
Remote user interface (EN, DE, RU, DA)
Digital I/O PCB
Demand PCB
Remote indoor sensor
PC cable
Wire harness
Room thermostat (wired)
Room thermostat (wireless)
External sensor
KGSFILL
EKRUCBL1
EKRUCBL2
EKRUCBL3
EKRUCBL4
EKRUCBL5
EKRUCBL6
EKRUCBL7
EKRP1HBAA
EKRP1AHTA
KRCS01-1
EKPCCAB2
EKGSCONBP1
EKRTWA
EKRTR1
EKRTETS
Daikin Altherma low temperature split
Drain pan for outdoor (excl heater)
Drain pan heater
U-beams for outdoor
Remote sensor for outdoor
Remote user interface (DE, FR, NL, IT)
Remote user interface (EN, SV, NO, FI)
Remote user interface (EN, ES, EL, PT)
Remote user interface (EN, TR, PL, RO)
Remote user interface (DE, CS, SL, SK)
Remote user interface (EN, HR, HU, BG)
Remote user interface (EN, DE, RU, DA)
Indoor drain pan for new wall mounted H/B
PC cable
Digital I/O PCB
Bottom plate heater
Drain kit
Snowcover
Demand PCB
Remote indoor sensor
Drain pan for indoor wall munted
Booster heater for tank integrated design
Daikin Altherma integrated solar unit
Room thermostat
Mixer module
Gateway for apps
9kW backup heater
Daikin Altherma low temperature monobloc
Back up heater
Cable
Digital I.O PCB
Bottom plate heater
Drain kit
440
4-8 kW
EKDP008CA
EKDPH008CA
EKFT008CA
Daikin Altherma hybrid heat pump
Weather Slate Steep PF 80/125 25°-45° Ral-9011
Weather Slate Steep Pb/GLV 80/125 43°-47°
Weather Slate Steep Pb/GLV 80/125 48°-52°
Weather Slate Steep Pb/GLV 80/125 53°-57°
Weather Slate Flat Alu 80/125 0°-15°
Weather Slate Flat Alu 80/125
Wall Terminal Kit PP/GLV 80/125
Extension PP/GLV 80/125 x 500mm
Extension PP/GLV 80/125 x 10000mm
Elbow PP/GLV 80/125 30°
Elbow PP/ALU 80/125 45°
Elbow PP/ALU 80/125 90°
Inspection Elbow Plus PP/ALU 80/125 90° EPDM
Wall Bracket Dn.100
Flex Kit PP Dn.60-80
Chimney Connection 60/100
Flex Kit PP Dn.80
Chimney Connection 80/125
Extension Flex PP 80 L=10 M
Extension Flex PP 80 L=15 M
Extension Flex PP 80 L=25 M
Extension Flex PP 80 L=50 M
Connector Flex-Flex PP 80
Spacer PP 80-100
Tee Flex 100 Boiler Connectionset 1
Flex 100-60 + Support Elbow
Tee Flex 130 Boiler Connectionset 1
Flex 130-60 + Support Elbow
Chimney Connection 60/100
Extension PP 60x500
Chimney Top PP 100 incl. Flue Pipe
Adapter Flex-Fixed PP 100
Support Breaket Top Inox Dn.100
Extension Flex PP 100 L=10 M
Extension Flex PP 100 L=15 M
Extension Flex PP 100 L=25 M
Connector Flex-Flex PP 100
Chimney Top PP 130 incl. Flue Pipe
Adapter Flex-Fixed PP 130
Support Breaket Top Inox Dn.130
Extension Flex PP 130 L=30 M
Connector Flex-Flex PP 130
Valve kit
11-16 kW
EKRSCA1
EKRUCBL1
EKRUCBL2
EKRUCBL3
EKRUCBL4
EKRUCBL5
EKRUCBL6
EKRUCBL7
EKHBDPCA2
EKPCCAB1
EKRP1HBAA
EKBPHTH16A
EKDK04
EK016SNCA
EKRP1AHTA
KRCS01-1B
EKHBDPCA2
EKBSHCA3V3
EHS157034
EHS157068
EHS157056
EKBU9C
6-8 kW
EKMBUHBA6V3
EKCOMCAB1
11-16 kW
EKRP1HBAA
EKBPHTH16A
EKDK04
EKFGP7909
EKFGT6305
EKFGT6306
EKFGT6307
EKFGP1297
EKFGW5333
EKFGW6359
EKFGP4801
EKFGP4802
EKFGP4814
EKFGP4811
EKFGP4810
EKFGP4820
EKFGP4481
EKFGP1856
EKFGP4678
EKFGP2520
EKFGP4828
EKFGP6340
EKFGP6344
EKFGP6341
EKFGP6342
EKFGP6324
EKFGP6333
EKFGP6368
EKFGP6354
EKFGP6215
EKFGS0257
EKFGP4678
EKFGP5461
EKFGP5497
EKFGP6316
EKFGP6337
EKFGP6346
EKFGP6349
EKFGP6347
EKFGP6325
EKFGP5197
EKFGS0252
EKFGP6353
EKFGS0250
EKFGP6366
EKVK1A
EKVK2A
EKVK3A
EKHYPART
Daikin Altherma high temperature split
Bottom plate heater
Digital I/O PCB
Demand PCB
Remote user interface
Back up heater for HT
Back up heater for HT
Refrigerant stop valves
UK tank kit
Compatibility kit 1
Compatibility kit 2
Daikin Altherma Flex Type
options for outdoor unit
Refnet header
Refnet header
Refnet joint
Refnet joint
Refnet joint
central drain pan kit
options for indoor unit
Stand alone kit
I/O PCB
Demand PCB
Remote user interface
Individual billing - connection kit
Back up heater kit
Back up heater kit
EKBPHTH16A
EKRP1HBAA
EKRP1AHTA
EKRUAHTB
EKBUHAA6V3
EKBUHAA6W1
EKRSVHTA
EKUHWHTA
EKMKHT1A
EKMKHT2A
EKHVMRD
KHRQ(M)22M29H8
KHRQ(M)22M64H8
KHRQ(M)22M20T8
KHRQ(M)22M29T8
KHRQ(M)22M64T8
KWC25C450
EKHVMYD
KHRQ(M)23M29H8
KHRQ(M)23M64H8
KHRQ(M)23M20T8
KHRQ(M)23M29T8
KHRQ(M)23M64T8
KWC25C450
EKFMAHTB
EKRP1HBAA
EKRP1AHTA
EKRUAHTB
EKMBIL1
EKBUHAA6V3
EKBUHAA6W1
Tanks
Wall bracket
Connection kit EKHWP300 for low temperature (heating only / heating and cooling)
Connection kit EKHWP500 for low temperature (heating only)
Connection kit EKHWP500 for low temperature (heating and cooling)
Connection kit for high temperature and VRV indoor HXHD125 (EKHWP300/
EKHWS
EKWBSWW150
Solar collectors
Mounting kit on roof (antracite)
Mounting kit on roof (red)
Mounting kit on roof (excl. Roof tile)
Gravity brake
Flow sensor
Flow regulating valve with flow rate indicator
Connection set for additional heat source
Hot water recirculation kit
Thermostatic antiscald mixing valve + 1” screw connection set
Solar Expansion vessel 12l
Solar Expansion vessel 25l
Solar Expansion vessel 35l
Pressureless Connection piping between solar panel & pump station: 15 meter
Pressureless Connection piping between solar panel & pump station: 20 meter
Unpressurised elongation pipe 2.5 m including couplings
Unpressurised elongation pipe 5 m including couplings
Unpressurised elongation pipe 10 m including couplings
Unpressurised elongation for inlet pipe 8 meter
Pressure solar pipe DN16 - 15m
Connectors DN16
Pressure solar pipe DN20 - 15m
Connectors DN20
Connectors DN20
Connectors DN20
Mounting kit IN-ROOF
Mounting kit FLAT ROOF
Additional roof breakthrough for opposite side connection
Connection kit between 2 solar panels
Connection kit between 2 rows of Collectors
Connection kit between 2 rows of Collectors
Mounting support for V26P
Mounting support for H26P
Mounting support for V21P
Suporting shell for pressureless connection pipe
Standard mounting set for on-roof mounting suitable for roof tiles
Variable height mounting set for on-roof mounting suitable for roof tiles
Mounting set for on-roof mounting
Mounting set for on-roof mounting suitable for flat tiles e.g. shingles
Mounting set for on-roof mounting suitable for corrugated plates
Mounting set for on-roof mounting suitable for metal roofs
Basic IN ROOF installation kit for 2 EKSV21P
Extension IN ROOF installation kit for 1 additional EKSV21P
Basic IN ROOF installation kit for 2 EKSV26P
Extension IN ROOF installation kit for 1 additional EKSV26P
IN ROOF covering slate complementing kit
Basic FLAT ROOF support frame for 2 EKSV26P
Extension FLAT ROOF support frame for additional EKSV26P
Basic FLAT ROOF support frame for 1 EKSH26P
Extension FLAT ROOF support frame for additional EKSH26P
Release tool
Glycol fluid 20 l
EKHTS
EKEPHT3H / EKEPHT5H
EKHWP500)
Connection kit for Daikiin Altherma Flex Type (heating only)
Connection kit for Daikiin Altherma Flex Type (heating and cooling)
3 way valve
Booster heater with melting fuse (900mm)
Option kit (EKHTS / EKHTSU)
Heat pump convector
Valve kit
EKHWP
EKDVCPLT3HX
EKDVCPLT5H
EKDVCPLT5X
EKEPHT3H
EKEPHT3H + 156034
3-W-UV2
EKBH3S
EKFMALTA / EKUHWHTA
EKVKHPC
EKSRCAP
EKSRCRP
EKSRCP
16 50 70
FLS12
FLG
EWS
ZKL
VTA32 + 156016
MAGS12
MAGS25
MAGS35
CON 15
CON 20
CON X 25
CON X 50
CON X 100
CON XV 80
CON15P16
CONXP16
CON15P20
CONXP20
CON CP16
CON CP20
RCIP
RCFP
CON FE
FIX VBP
CON RVP
CON LCP
FIX MP 130
FIX MP 200
FIX MP 100
TS
FIX AD
FIX ADP
FIX ADD
FIX ADS
FIX - WD
FIX BD
IBV21P
IEV21P
IBV26P
IEV26P
FIX-IES
FB V26P
FE V26P
FB H26P
FE H26P
FIX LP
GFL
441
Adapters and controls
Options - Split
FTXZ-N
FTXJ-LW/S
FTXG-LW/S
FTXM-K
CTXS15-35K
FTXS20-25K
FTXS35-50K
Wired remote control
-
BRC944 (3)
BRC944 (3)
BRC944 (3) (5)
BRC944 (3) (5)
BRC944 (3)
Wireless remote control
-
-
-
-
-
-
Simplified remote control
-
-
-
-
-
-
Remote control for hotel use
-
-
-
-
-
-
Cord for wired remote control - 3m
-
BRCW901A03
BRCW901A03
BRCW901A03
BRCW901A03
BRCW901A03
Cord for wired remote control - 8m
-
BRCW901A08
BRCW901A08
BRCW901A08
BRCW901A08
BRCW901A08
KRP413A1S (1)
((5) (20-25 class))
KRP413A1S (1) (5)
KRP413A1S (1)
Wiring adapter normal open contact / normal open pulse contact
Centralised control board - up to 5 rooms
KRP413A1S (1)
KRP413A1S (1)
KRC72 (2)
KRC72 (2)
KRC72 (2)
KRC72 (2)
KRC72 (2)
KRC72 (2)
KKF910A4
KKF910A4
KKF936A4
KKF910A4
KKF910A4
KKF910A4 (20-25 class)
KKF910A3 (35-42-50 class)
Interface adapter for wired remote control
-
-
-
KRP980A1 (20-25 class)
KRP980A1
-
Wiring adapter for electrical appendices
-
-
-
-
-
-
Remote sensor
-
-
-
-
-
-
Installation box for adapter PCB
-
-
-
-
-
-
Electric box with earth terminal 3 blocks
-
-
-
-
-
-
Electric box with earth terminal 2 blocks
-
-
-
-
-
-
KRP928A2S
KRP928BA2S
KRP928A2S
KRP928A2S (5)
KRP928A2S (5)
KRP928A2S (5)
BRP069A42 (available
from 01/15)
BRP069A41
BRP069A41
BRP06942 (5) (20-25 class)
BRP06941 (35-42-50 class)
BRP06942 (5)
BRP06942
Anti-theft protection for remote control
Interface adapter for DIII-net
Online controller
Others
KRP413A1S (1)
Modbus gateway
RTD-RA
RTD-RA
RTD-RA
RTD-RA
RTD-RA (5)
RTD-RA
KNX gateway
KLIC-DD
KLIC-DD
KLIC-DD
KLIC-DD
KLIC-DD (5)
KLIC-DD
Titanium apatite photocatalytic air-purification filter without frame
-
KAF970A46
-
KAF970A46
(20-25 class)
-
-
Photocatalytic deodorising filter, with frame
-
-
-
-
-
-
Photocatalytic deodorising filter, without frame
-
-
-
-
-
-
Air purification filter, with frame
-
-
-
-
-
-
Installation leg
-
-
-
-
-
-
(1) Wiring adapter supplied by Daikin. Time clock and other devices : to be purchased locally; (2) Wiring adapter is also required for each indoor unit; (3) Cord for wired remote control BRCW901A03 or
BRCW901A08 required; (4) Standard there is no remote control delivered with this indoor unit. Wired or wireless control to be ordered separately; (5) Interface adapter KRP980A1 required.
SIESTA INDOOR UNITS
ATXL-JV
ATXS-K
ATX-J3
ATX-K
BRC944 (3) (5)
BRC944 (3)
BRC944 (3) (5)
BRC944 (3) (5)
Wireless remote control
-
-
-
-
Simplified remote control
-
-
-
-
Remote control for hotel use
-
-
-
-
Cord for wired remote control - 3m
BRCW901A03
BRCW901A03
BRCW901A03
BRCW901A03
Cord for wired remote control - 8m
Adapters and controls
Wired remote control
BRCW901A08
BRCW901A08
BRCW901A08
BRCW901A08
Wiring adapter normal open contact / normal open pulse contact
-
KRP413AB1S (1)
-
-
Centralised control board - up to 5 rooms
-
KRC72A (2)
-
-
Anti-theft protection for remote control
KKF917A4
KKF910A4
KKF910A4
KKF917A4
Interface adapter for wired remote control
KRP980A1
KRP980A1
KRP980A1
KRP980A1
Wiring adapter for electrical appendices
-
-
-
-
Remote sensor
-
-
-
-
Installation box for adapter PCB
-
-
-
-
Electric box with earth terminal 3 blocks
-
-
-
-
Electric box with earth terminal 2 blocks
-
-
-
-
Interface adapter for DIII-net
-
KRP928BB2S
-
-
BRP06942 (5)
BRP069A42
BRP06942 (5)
BRP06942 (5)
Modbus gateway
RTD-RA (5)
-
RTD-RA (5)
RTD-RA (5)
KNX gateway
KLIC-DD (5)
-
KLIC-DD (5)
KLIC-DD (5)
Titanium apatite photocatalytic air-purification filter without frame
KAF971A42
-
KAF971A42
-
-
-
-
-
Others
Online controller
Photocatalytic deodorising filter, with frame
Photocatalytic deodorising filter, without frame
-
-
-
-
Air purification filter, with frame
-
-
-
-
Installation leg
-
-
-
-
RXZ-N
RXJ-L
RXG-L
RXM-L
RXS-L(3)
RXS-F8
-
-
KPW945A4
(50 class)
-
-
-
-
KKP945A4
-
KKP945A4
-
-
KPMJ983A4L
-
-
-
-
-
Others
Air direction adjustment grille
Drain plug
Humidifying hose L joint (10 pcs.)
L-shape cuffs for humidification (10pcs)
KPMH950A4L
-
-
-
-
-
Humidifying hose extension set 2m
KPMH974A402
-
-
-
-
-
Hose for humidification (10m)
KPMH974A42
-
-
-
-
-
Notes: (1) Wiring adapter supplied by Daikin. Time clock and other devices : to be purchased locally; (2) Wiring adapter is also required for each indoor unit; (3) Cord for wired remote control BRCW901A03 or
BRCW901A08 required; (4) Standard there is no remote control delivered with this indoor unit. Wired or wireless control to be ordered separately; (5) Interface adapter KRP980A1 required.
442
INDOOR UNITS
FTXS-G
FTX-J3
FTX-GV
FTX-K
FVXG-K
FVXS-F
FDXS-F(9)
FLXS-B(9)
FTXLS-K
FTXL-JV
BRC944 (3)
BRC944B2 (3) (5)
BRC944 (3)
BRC944B2 (3)
BRC944 (3)
-
BRC1D52
BRC1E52A
BRC1E52B (4)
-
BRC944 (3)
BRC944 (3) (5)
-
-
-
-
-
-
BRC4C65
-
-
-
-
-
-
-
-
-
BRC2C51
-
-
-
-
-
-
-
-
-
BRC3A61
-
-
-
BRCW901A03
BRCW901A03
BRCW901A03
BRCW901A03
BRCW901A03
-
-
-
BRCW901A03
BRCW901A03
BRCW901A08
BRCW901A08
BRCW901A08
BRCW901A08
BRCW901A08
-
-
-
BRCW901A08
BRCW901A08
KRP413A1S (1)
-
KRP413A1S (1)
-
KRP413A1S (1)
KRP413A1S (1)
-
KRP413A1S (1)
KRP413A1S (1)
-
KRC72 (2)
-
KRC72 (2)
-
KRC72 (2)
KRC72 (2)
-
KRC72 (2)
KRC72 (2)
-
KKF910A4
KKF917A4
KKF917AA4
KKF917A4
KKF910A4
-
-
KKF917AA4
KKF910A4
KKF917A4
-
KRP980A1
-
KRP980A1
-
-
-
-
-
KRP980A1
-
-
-
-
-
-
KRP4A54
-
-
-
-
-
-
-
-
-
KRCS01-4
-
-
-
-
-
-
-
-
-
KRP1BA101
-
-
-
-
-
-
-
-
-
KJB311A
-
-
-
-
-
-
-
-
-
KJB212A
KRP928A2S
-
KRP928A2S
-
KRP928A2S
KRP928A2S
-
KRP928A2S
KRP928BB2S
-
BRP069A42
BRP06942 (5)
BRP069A42
BRP069A42
BRP069A42
BRP069A42
-
BRP069A42
BRP069A42
BRP06942 (5)
RTD-RA
RTD-RA
RTD-RA (5)
RTD-RA
KLIC-DD
KLIC-DD (5)
KLIC-DD
-
KAF971A42
KAF952B42
-
-
-
-
-
-
RTD-RA
RTD-RA
RTD-NET
-
RTD-RA
RTD-RA (5)
KLIC-DD
KLIC-DD
KLIC-DI
KLIC-DD
KLIC-DD
KLIC-DD (5)
KAF970A46
-
-
-
-
KAF970A46
KAF971A42
-
-
-
-
-
KAZ917B41
-
-
-
-
-
-
-
KAZ917B42
-
-
-
-
-
-
-
-
KAF925B41
-
-
-
-
-
-
BKS028
-
-
-
-
-
RX-K
RX-GV(B)
RXLG-M
RXLS-M
RXL-M(3)
ARXL-M
ARXS-L(3)
ARX-K
MXS-E/F/G/H/K
AMX-G/E
KPW937C4
KPW945A4
-
-
-
-
-
KPW937C4
KPW945A4
-
OUTDOOR UNITS
KKP937A4
-
-
-
-
-
-
KKP937A4
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
*Note: blue cells contain preliminary data
443
Options INDOOR UNITS
Description
Wired remote control
Intelligent touch controller
Infrared remote control (heat pump)
Simplified remote control (with operation mode selector
button)
Simplified remote control (without operation mode
selector button)
Residential central remote control
Remote control for hotel use
Centralised remote control
Unified ON/OFF control
Schedule timer
Adapter for wiring (interlock for fresh air intake fan)
Adapter for external ON/OFF and monitoring/for electrical
appendices
Interface adapter for Sky Air
Installation box for adapter PCB
FCQHG-F
FCQG-F
FFQ-C
ACQ-D
FDBQ-B
FBQ-D
BRC1D52
BRC1E52A (3)
BRC1E52B (4)
BRC1D52
BRC1E52A (3)
BRC1E52B (4)
BRC1D528
BRC1E52A (3)
BRC1E52B(4)(9)
ARCWB
BRC1D52
BRC1E52A (3)
BRC1E52B (4)
BRC1D52
BRC1E52A (3)
BRC1E52B (4)
DCS601C51
DCS601C51
-
-
DCS601C51 (2)
BRC7FA532F (5)
BRC7FA532F (5)
DCS601C51
BRC7EB530W
BRC7F530W
BRC7F530S (8-9)
ADP125A (11)
-
BRC4C65
-
-
BRC2E52C (12)
-
-
BRC2E52C (12)
-
-
BRC3E52C (12)
-
-
-
BRC3A61
DCS302C51
DCS301B51
DST301B51
KRP1B57
KRP4A53 (1)(5)
-
BRC3A61
DCS302C51
DCS301B51
DST301B51
KRP1B57
KRP4A53 (1)(5)
-
-
-
KRP1H98 (5)
KRP1H98 (5)
DCS302B51
DCS301B51
DST301B51
KRP1B57
KRP4A53(6)
KRP1B101
KRP1BA101
KRCS01-4
EKRP1B2
BRP7A51 (1) (13)
-
-
-
-
BRC3E52C
DCS302C51
DCS301B51
DST301B51
KRP1BA59
KRP4A52 (1)
KRP2A51 (1)
DTA112B51
-
-
KRP1B(A)101
Remote sensor
KRCS01-4
KRCS01-4
KRCS01-4B
Remote ON/OFF, forced OFF
EKRORO2
Electrical box with earth terminal (3 blocks)
KJB311A
KJB311A
Electrical box with earth terminal (2 blocks)
KJB212A
KJB212A
Electrical box with earth terminal
KJB411A
Adapter for wiring (hour meter)
EKRP1C11 (1)(5)
EKRP1C11 (1)(5)
EKRP1B2
Digital input adaptor
BRP7A51
Options PCB for external electrical heater, humidifier and/
EKRP1B2A (7)
or hour meter
Option PCB for group control (NIM03)
R04084124324
Mounting plate for adapter PCB
Notes: () Installation box for adapter PCB is necessary; () Interface adapter for Sky Air series (DTAB) is necessary; () Including following languages: English, German, French, Italian, Spanish, Dutch, Greek, Russian, Turkish,
Portuguese, Polish; () Including following languages: English, German, Czech, Croatian, Hungarian, Romanian, Slovenian, Bulgarian, Slovak, Serbian, Albanian; () Option not available in combination with BYCQ*G; ()
Installation box for adapter PCB (KRPB) is necessary; () Electrical heater, humidifier and hour meter are field supply. These parts should not be installed inside the equipment; () Sensing function is not available; ()
Independently controllable flaps function is not available; () With the infrared remote control, the individual flap control and automatic air volume control cannot be controlled; () Including decoration panel; () Including
following languages: English, German, French, Dutch, Spanish, Italian, Portuguese; () Only possible in combination with simplified remote control BRC/EC; () For residential use only. Cannot be used with other
centralised control equipment

INDOOR UNITS
FDQ-C
FDQ-B
ABQ-C
FAQ-C
FHQ-C
AHQ-C
FUQ-C
FNQ-A
FVQ-C
BRC1D52
BRC1E52A (3)
BRC1E52B (4)
BRC1D52
BRC1E52A (3)
BRC1E52B (4)
-
BRC1D52
BRC1E52A (3)
BRC1E52B (4)
BRC1D52
BRC1E52A (3)
BRC1E52B (4)
ARCWB
BRC1D52
BRC1E52A (3)
BRC1E52B (4)
DCS601C51
-
-
DCS601C51
-
-
-
BRC1D52
BRC1E51A
BRC1E52A
BRC1E52B
-
BRC4C65
-
-
BRC7EB518
BRC7G53
-
BRC7C58 (10)
BRC4C65
-
-
-
-
BRC2C51
-
-
-
BRC2E52C (12)
BRC2E52C
-
-
-
-
-
-
-
-
-
DCS302C51
DCS301B51
DST301B51
KRP1C64
DCS302C51
DCS301B51
DST301B51
KRP1B54
-
BRC3A61
DCS302C51
DCS301B51
DST301B51
-
-
DCS302C51
DCS301B51
DST301B51
-
DCS303A51
BRC3E52C7 (3) (15)
DCS302CA51
DCS301BA51
DST301BA51
-
KRP4A51
KRP4A51
-
KRP4A51 (1)
-
KRP4A53 (1)
KRP4A54
-
DTA112B51
-
-
DCS302C51
DCS301B51
DST301B51
KRP1B54
KRP4A52(1)
-
-
-
-
BRC3A61
DCS302C51
DCS301B51
DST301B51
KRP1B57
KRP4A52
-
-
-
-
KRP4A93
KRP1D93A
-
KRP1B97
KRP1BA101
KRP4AA95
KRCS01-4B
EKRORO3
-
EKRORO
-
-
KRCS01-1
KJB311A
KJB212A
-
KRCS01-4B
EKRORO4
KJB311A
KJB212A
-
-
KRCS01-4
EKRORO5
KJB311A
KJB212A
-
KRCS01-4B
KJB212AA
KJB311AA
BRP7A51 (1) (13)
-
EKRP1B2
EKRP1B2
-
-
-
-
-
-
-
KRP4A96
-
R04084124324
-
-
-
R04084124324
-
-
-
-
BRC1D52
BRC1E52A (3)
BRC1E52B (4)
DCS301C51
-
*Note: blue cells contain preliminary data

Options -
INDOOR UNITS
Description
FCQHG-F
FCQG-F
FFQ-C
ACQ-D
FDBQ-B
FBQ-D
KAFP551K160
KAFP551K160
KAFQ441BA60
-
-
-
Standard
Standard
Standard
Standard
-
Standard
-
-
-
-
-
-
Sealing member of air discharge outlet
Decoration panel for air discharge
KDBHQ55B140 (4)
-
KDBHQ55B140 (4)
-
BDBHQ44C60
-
-
-
Decoration panel
BYCQ140D
BYCQ140DW(1)
BYCQ140DG (2)(3)
BYCQ140D
BYCQ140DW(1)
BYCQ140DG (2)(3)
BYFQ60B3
BYFQ60C2W1W
BYFQ60C2W1S (6)
ADP125A (10)
-
KDDQ55B140-1 (4)
KDDQ55B140-2 (6)
KDDQ55B140-1 (4)
KDDQ55B140-2 (6)
-
-
-
BYBS32D (35 class)
BYBS45D (50 class)
BYBS71D (60-71 class)
BYBS125D (100-140 class)
EKBYBSD (9)
KDDQ44XA60
-
-
Replacement long-life filter
Drain pump kit
L-type piping kit (upward direction)
Kit for mounting of decoration panel direct onto unit
Fresh air intake kit (direct installation type)
-
Air discharge adapter for round duct
-
-
-
-
KDBQ44B60
BRYQ60A2W
BRYQ60A2S (7)
-
-
-
-
-
Sensor kit
BRYQ140A (5)
BRYQ140A (5)
Noise filter
-
-
Panel spacer
KDAJ25K36A (35 class)
KDAJ25K56A (50 class)
KDAJ25K71A (60-71 class)
KDAJ25K140A (100-140 class)
-
-
-
-
-
-
-
Notes: () The BYCQDW has white insulations. Be informed that dirt is more visible on white insulation and that it is consequently not advised to install the BYCQDW decoration panel in environments
OUTDOOR UNITS
Description
Central drain plug
Refrigerant branch piping
For twin
For triple
For double
twin
RZQG-L9V1/L(8)Y1
RZQSG-L3/9V1/L(8)Y1
RZQ-C
AZQS-B8V1/BY1
KHRQ22M20TA (KHRQ58T) ²
KHRQ127H (KHRQ58T) ²
KHRQ22M20TA (KHRQ58T) ²
KHRQ127H (KHRQ58T)²
KWC26B280
KHRQ22M20TA
KHRQ250H7
-
KHRQ22M20TA (3x) (KHRQ58T)²
KHRQ22M20TA (3x) (KHRQ58T)²
KHRQ22M20TA (x3)
-
KRP58M51 (71 class)
KRP58M51 (71 class)
Demand adapter kit
KRP58M51MK
KRP58M51
KRP58M51MK
KRP58M51MK
Bottom plate heater
EKBPH140L7 1
Notes: () Bottom plate heater is only available for RZQG* models; () For combination of RZQ(S)G- in combination with FCQG-F or FCQHGF use the refrigerant branch piping mentioned between brackets;
() For RZQG
ROOFTOPS
Description
Rooftop controller
PCB
EXV
Gold Fin (NA549)
Scroll compressor
Saranet Air Filter
Side flow
Convertible
Filter drier
High pressure switch
Low pressure switch
Economiser

UATYQ-C
UATYP-AY1(B)
t
t
t
t
t
t
t
t
t
t
t
-
ECONO-AY1
-
-
INDOOR UNITS
FDQ-C
FDQ-B
ABQ-C
FAQ-C
FHQ-C
AHQ-C
FUQ-C
FNQ-A
FVQ-C
-
-
-
-
Standard
-
-
K-KDU572EVE
-
-
-
-
-
-
-
-
KAFP501A56 (35-50 class)
KAFP501A80 (60-71 class)
KAFP501A160 (100-125 class)
KDU50P60 (35-60 class)
KDU50P140 (71-125 class)
KHFP5M35 (35 class)
KHFP5N63 (50-60 class)
KHFP5N160 (71-125 class)
-
-
KAFP551K160
-
KAFJ95L160
-
-
-
-
-
-
-
-
-
KDBHP49B140
KDBTP49B140
-
-
BYBS125D(9)
BYBS125D(9)
-
-
-
-
-
-
-
EKBYBSD
EKBYBSD
-
-
-
-
-
-
-
-
-
-
-
KDDQ50A140
-
-
-
-
KDAJ25K140A
KDAJ25K140A
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
KEK26-1A
-
-
-
KEK26-1A
-
*Note: blue cells contain preliminary data

Options & accessories -
outdoor
VRV IV with continuous heating
2-module
systems
RYYQ8-12T RYYQ14-20T RYMQ8-12T RYMQ14-20T
Multi-module connection kit (obligatory) - Connects multiple modules into a single
refrigerant system
Extended level difference kit - Allows outdoor unit to be more than 50m
above indoor units
Central drain pan kit - Installs onto the underside of the outdoor unit and collects drain
water from all bottom plate outlets into a single outlet. In cold areas should be heated by
a field-supplied heater to prevent drain water from freezing in the drain pan.
Heater tape kit - Optional electrical heater to guarantee trouble-free operation in
extremely cold and humid climates (one per outdoor unit needed)
External control adapter for outdoor unit - Allows to activate Low Noise Operation
and three levels of Demand Limiting via external dry contacts. Connects to the F1/F2
communication line and requires power supply from an indoor unit*, BSVQ box, or VRV-WIII
outdoor unit.
BHGP26A1 - Digital pressure gauge kit – displays current condensing and evaporating
pressures in the system as standard, or expansion valve positions and temperature sensor
data in a special service mode. Connect to the outdoor unit PCB, for installation in the
outdoor unit.
KRC19-26A - Mechanical cool/heat selector – allows to switch an entire Heat Pump system,
or one BS-box of a Heat Recovery system between cooling, heating and fan only. Connects
to the A-B-C terminals of the outdoor unit / BS-box.
VRV IV without
-
-
-
-
-
-
-
-
-
-
-
-
-
EKBPH012T +
EKBPHPCBT
EKBPH020T +
EKBPHPCBT
EKBPH012T +
EKBPHPCBT
EKBPH020T +
EKBPHPCBT
3-module
RXYQ8-12T RXYQ14-20T
systems
BHFQ22P1007 BHFQ22P1517
-
-
-
-
-
-
-
-
-
-
-
EKBPH012T
+ EKBPHPCBT
EKBPH020T
+ EKBPHPCBT
For installation into an indoor unit: exact adapter type depends on type of indoor unit.
See Options & Accessories of indoor units
t
t
t
t
1 kit
per system
1 kit
per system
t
t
t
t
t
t
t
t
t
t
BRP2A81 - Cool/heat selector PCB (required for VRV IV)
t
t
t
t
t
t
t
t
KKSA26A560* - Cool/heat selector PCB mounting plate (only required when cool/heat
selector PCB and Heater tape kit are combined)
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
BPMKS967A2/A3 - Branch provider (for connection of 2/3 RA indoor units)
t
t
t
-
-
-
-
t
t
t
t
t
t
KKPJ5F180 - Central drain plug
-
-
-
-
-
-
-
-
DTA104A61/62* - Demand PCB allowing external input to limit power consumption
t
t
t
-
-
-
DTA109A51 - DIII-net expander adapter
t
t
t
t
t
-
t
t
t
t
KKSB2B61* - Demand PCB mounted plate. Needed to mount Demand PCB for some outdoor units.
t
t
t
t
t
t
KJB111A - Installation box for remote cool/heat selector KRC19-26A
EKPCCAB3 - VRV configurator
-
t
VRV IV-Q Heat Pump Replacement VRV
Multi-module connection kit (obligatory) - Connects multiple modules into a single
refrigerant system
Central drain pan kit - Installs onto the underside of the outdoor unit and collects drain
water from all bottom plate outlets into a single outlet. In cold areas should be heated by a
field-supplied heater to prevent drain water from freezing in the drain pan.
RQYQ 140
RXYQQ8-12T
RXYQQ14-20T
-
-
-
BHFQ22P1007
BHFQ22P1517
KWC26B160
-
-
-
-
-
EKBPH012T +
EKBPHPCBT
EKBPH020T +
EKBPHPCBT
-
-
Heater tape kit - Optional electrical heater to guarantee trouble-free operation in
extremely cold and humid climates (one per outdoor unit needed)
External control adapter for outdoor unit - Allows to activate Low Noise Operation
and three levels of Demand Limiting via external dry contacts. Connects to the F1/F2
communication line and requires power supply from an indoor unit*, BSVQ box, or VRV-WIII
outdoor unit.
BHGP26A1 - Digital pressure gauge kit – displays current condensing and evaporating
pressures in the system as standard, or expansion valve positions and temperature sensor
data in a special service mode. Connect to the outdoor unit PCB, for installation in the
outdoor unit.
KRC19-26A - Mechanical cool/heat selector – allows to switch an entire Heat Pump system,
or one BS-box of a Heat Recovery system between cooling, heating and fan only. Connects
to the A-B-C terminals of the outdoor unit / BS-box.
2-module systems 3-module systems
DTA104A53/61/62
For installation into an indoor unit: exact adapter type depends on type of indoor unit.
See Options & Accessories of indoor units
t
t
t
1 kit per system
1 kit per system
t
t
t
1 kit per system
1 kit per system
BRP2A81 - Cool/heat selector PCB (required for VRV IV)
-
t
KKSA26A560* - Cool/heat selector PCB mounting plate (only required when cool/heat
selector PCB and Heater tape kit are combined)
-
-
t
t
t
t
t
t
t
t
t
t
t
t
t
t
1 kit per system
1 kit per system
t
t
t
t
KJB111A - Installation box for remote cool/heat selector KRC19-26A
t
EKPCCAB3 - VRV configurator
-
DTA104A61/62* - Demand PCB allowing external input to limit power consumption
-
KKSB2B61* - Demand PCB mounted plate. Needed to mount Demand PCB for some
outdoor units.
-
-
DTA109A51 - DIII-net expander adapter
t
t
-
-
t
t
Heat Pump
systems (2-pipe)
Heat Recovery systems (3-pipe)
Refnet Joints
448
Metric-size connections
Imperial-size connections
Sound reduction kit (sound insulation)
Mechanical cool/heat selector – allows to switch an entire Heat Pump system, or
one BS-box of a Heat Recovery system between cooling, heating and fan only.
Connects to the A-B-C terminals of the outdoor unit / BS-box.
Installation box for remote cool/heat selector KRC19-26
Closed pipe kit
Joint kit
Quiet kit
Metric-size connections
Imperial-size connections
Refnet Headers
Capacity index
Capacity index
Capacity index
Capacity index
Capacity index
< 201
201~290
291~640
> 640
< 291
Capacity index
291~640
KHRQM23M20T
KHRQ23M20T
-
KHRQM23M29T
KHRQ23M29T9
-
KHRQM23M64T
KHRQ23M64T
-
KHRQM23M75T
KHRQ23M75T
-
KHRQM23M29H
KHRQ23M29H
-
KHRQM23M64H
KHRQ23M64H
-
-
-
-
-
-
-
-
-
-
-
-
-
KHRQM22M20T
KHRQM22M29T
KHRQM22M64T
KHRQM22M75T
KHRQM22M29H
KHRQM22M64H
KHRQ22M20T
KHRQ22M29T9
KHRQ22M64T
KHRQ22M75T
KHRQ22M29H
KHRQ22M64H
Options & accessories -
continuous heating
VRV III-S
Mini VRV
VRV III-C Cold Region VRV
RTSYQ 10 RTSYQ 14~16 RTSYQ 20
VRV Classic
VRV IV Heat Recovery
2-module
systems
3-module
systems
RXYSQ
BHFQ22P1007
BHFQ22P1517
-
-
-
BHFQ22P1007
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
KWC26B280
KWC26B450 2x KWC26B280 KWC26B160
KWC26B280
KWC26B450
-
-
-
-
-
BEH22A10Y1L
BEH22A18Y1L
-
-
EKBPH012T +
EKBHPCBT
EKBPH020T +
EKBHPCBT
RXYCQ8A
2x BEH22A10Y1L
REMQ5
2-module
systems
3-module
systems
-
BHFQ23P907
BHFQ23P1357
-
-
-
EKBPH012T +
EKBHPCBT
-
-
RXYCQ10-14A RXYCQ16-20A REYQ 8~12 REYQ 14~20
-
outdoor
-
-
Special order unit
For installation into an indoor unit: exact adapter type depends on type of indoor unit.
See Options & Accessories of indoor units
1 kit
per system
1 kit
per system
-
t
t
t
t
t
t
t
t
t
1 kit
per system
1 kit
per system
t
t
t
-
-
-
t
t
t
-
-
-
-
-
t
t
-
-
-
-
-
-
-
-
-
-
-
-
t
t
-
-
-
-
-
-
-
-
-
-
-
-
t
t
t
t
t
-
-
-
t
t
t
-
-
-
-
-
-
-
-
-
-
-
-
t
t
t
t
t
-
-
-
-
-
-
-
-
-
-
-
-
-
t
t
-
-
-
-
-
-
-
-
-
-
-
-
-
t
t
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
t
t
t
t
t
t
t
t
t
t
t
t
t
t
VRV-W IV Water-cooled VRV
VRV III-Q Heat Recovery Replacement VRV
RQEQ 140~212
Heat Pump application
2-module systems 3-module systems 4-module systems
RWEYQ8-10T
Heat Recovery application
2-module systems 3-module systems 2-module systems 3-module systems
-
BHFP26P36C
BHFP26P63C
BHFP26P84C
-
BHFQ22P1007
BHFQ22P1517
BHFQ23P907
BHFQ23P1357
KWC26B160
1 kit per module
1 kit per module
1 kit per module
-
-
-
-
-
-
-
-
-
-
-
-
-
-
DTA104A53/61/62
For installation into an indoor unit: exact adapter type depends on type of indoor unit.
See Options & Accessories of indoor units
DTA104A62
Installation in the RWEYQ outdoor unit possible. For installation in indoor units, use appropriate type
(DTA104A53/61/62) for particular indoor unit. See Options & Accessories of indoor units
t
1 kit per system
1 kit per system
1 kit per system
-
-
-
-
-
-
-
-
-
t
1 kit per system
1 kit per system
-
-
-
-
-
-
t
1 kit per system
1 kit per system
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1 kit per system
1 kit per system
-
-
-
-
-
-
t
t
t
t
t
t
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
t
t
t
t
t
t
t
t
t
Heat Recovery Branch Selector Boxes (BS-Boxes)
Capacity index
1-port
1-port
4-port
4-port
6-port
6-port
8-port
10-port
12-port
16-port
> 640
-
-
-
-
-
-
-
-
-
-
KHRQM23M75H
KHRQ23M75H
-
BS1Q-A
EKBSVQLNP
BSVQ-P8B
EKBSVQLNP
BS4Q14A
-
BSV4Q100PV
-
BS6Q14A
-
BSV6Q100PV
-
BS8Q14A
BS10Q14A
BS12Q14A
BS16Q14A
-
-
KRC19-26
-
KRC19-26
1 kit per port
necessary
-
-
KJB111A
KHFP26A100C
KHRP26A1250C
KDDN26A4
KJB111A
KHFP26A100C
KHRP26A1250C
KDDN26A8
KHFP26A100C
KHRP26A1250C
KDDN26A12
KHFP26A100C
KHRP26A1250C
KDDN26A12
KHFP26A100C
KHRP26A1250C
KDDN26A16
KHFP26A100C
KHRP26A1250C
KDDN26A8
KRC19-26
1 kit per port
necessary
KJB111A
KHRQM22M75H
-
-
-
-
-
KHRQ22M75H
-
-
-
-
-
*Note: blue cells contain preliminary data
449
Options & accessories -
indoor
Ceiling mounted cassette units
Round flow
(800x800)
FXFQ 20~125A
BRC1E52A/B
Premium wired remote control with full-text interface and back-light
t
t*4
FXZQ 15~50A
FXCQ 20~40A
FXCQ 50~63A
FXCQ 80 ~125A
t
t
t
t
t*4
t*4
t*4
t*4
BRC7FA532F
BRC7C52
BRC7C52
BRC7C52
BRC2E52A
Simplified wired remote control for heat recovery system
-
-
-
-
-
BRC3E52A
Simplified wired remote control for heat pump system
-
-
-
-
-
DCS302C51
Central remote control
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
Infrared remote control including receiver
DCS301B51
Unified ON/OFF control
Adapters and control
2-way blow
BRC7F530W *9*10
(white panel)
BRC7F530S *9*10
(grey panel)
BRC7EB530 *9*10
(standard panel)
BRC1D52
Standard wired remote control with weekly timer
DST301B51
Schedule timer
DCM601A51
Intelligent Touch Manager
External wired temperature sensor
External wireless temperature sensor
KRCS01-4
KRCS01-4
KRCS01-4
KRCS01-4
KRCS01-4
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
-
-
-
-
-
KRP4A53 *2*7
KRP4A53 *2
KRP4A51
KRP4A51
KRP4A51
Adaptor for wiring (interlock for fresh air intake fan)
Wiring adapter for external monitoring/control via dry contacts and
setpoint control via 0-140Ω
Wiring adapter for external central monitoring/control
(controls 1 entire system)
-
KRP2A52
KRP2A51
KRP2A51
KRP2A51
Wiring adapter with 4 output signals
(Compressor / Error, Fan, Aux. heater, Humidifier output)
EKRP1C11 *2*7
EKRP1B2
EKRP1B2
EKRP1B2
EKRP1B2
Wiring adapter with 2 output signals
(Compressor / Error, Fan output)
KRP1B57 *2*7
KRP1B57
-
-
-
Adapter for multi-tenant applications
(24VAC PCB power supply interface)
DTA114A61
DTA114A61
-
-
-
-
-
DTA104A61
DTA104A61
DTA104A61
External control adapter for outdoor unit
Installation box / Mounting plate for adapter PCBs
(For units where there is no space in the switchbox)
KRP1H98 *7
KRP1A101
KRP1C96
KRP1C96
KRP1C96
Connector for forced-off contact
standard
-
standard
standard
standard
Connection to centralized control
standard
-
-
-
-
Electrical box with earth terminal (2 blocks)
KJB212A
-
KJB212A
KJB212A
KJB212A
Electrical box with earth terminal (3 blocks)
KJB311A
-
KJB311A
KJB311A
KJB311A
Electrical box with earth terminal
-
-
-
-
-
Digital input adaptor
-
-
-
-
-
BYCQ140D7GW1 (self clean) *5/*6
BYCQ140D7W1W (white) *3
BYCQ140D7W1 (standard)
BYFQ60CW (white panel)
BYFQ60CS (grey panel)
BYFQ60B3 (standard panel)
BYBCQ40H
BYBCQ63H
BYBCQ125H
-
-
-
-
-
-
KDBQ44B60
(standard panel)
-
-
-
KDBHQ55B140 *7
BDBHQ44C60 (white & grey panel)
-
-
-
KDDQ55B140-1 +
KDDQ55B140-2 *7*8
KDDQ44XA60
-
-
-
Air discharge adapter for round duct
-
-
-
-
-
Filter chamber for bottom suction
-
-
KDDFP53B50
KDDFP53B80
KDDFP53B160
KAFP551K160
KAFQ441BA60
KAFP531B50
KAFP531B80
KAFP531B160
standard
standard
standard
standard
standard
BRYQ140A
BRYQ60AW (white panel)
BRYQ60AS (grey panel)
-
-
-
-
-
KEK26-1A
KEK26-1A
KEK26-1A
Decoration panel
(obligatory for cassette units, optional for others, rear panel for FXLQ)
Kit for mounting of decoration panel direct onto unit
Panel spacer for reducing required installation height
Sealing kit for 3-directional or 2-directional air discharge
Others
4-way (600x600)
Fresh air intake kit
Replacement long life filter
Drain pump kit
Sensor kit
Noise filter (for electromagnetic use only)
* Installation box is necessary for these adapters
* The BYCQDWW has white insulation
Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQDWW decoration panel
in environments exposed to concentrations of dirt"
* Not recommended because of the limitation of the functions
* To be able to control the BYCQDGW the controller BRCE is needed
* The BYCQDGW is not compatible with Mini VRV, Multi and Split Non-Inverter Outdoor units
* Option not available in combination with BYCQDGW
* Both parts of the fresh air intake are needed for each unit
* Sensing function not available
* Independently controllable flaps function not available
450
Options & accessories -
indoor
Concealed ceiling units (duct units)
Corner (1-way blow)
Small
Slim
Standard
FXKQ 25~40
FXKQ 63
FXDQ 20~25 M9
FXDQ 15~63A
FXSQ 15~32
FXSQ 40~50
FXSQ 63~80
FXSQ 100~140
t
t
t
t
t*4
t*4
t*4
t*4
t
t*4
t
t*4
t
t*4
t
t*4
BRC4C61
BRC4C61
BRC4C62
BRC4C65
BRC4C65
BRC4C65
BRC4C65
BRC4C65
-
-
-
-
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
KRCS01-1
KRCS01-1
KRCS01-1
KRCS01-4B
KRCS01-4
KRCS01-4
KRCS01-4
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
KRCS01-4
K.RSS
-
-
-
-
KRP1BA59
KRP1BA59
KRP1BA59
KRP1BA59
KRP4A51
KRP4A51
KRP4A51
KRP4A54
KRP4A51
KRP4A51
KRP4A51
KRP4A51
KRP2A51
KRP2A51
KRP2A51
KRP2A53
KRP2A51
KRP2A51
KRP2A51
KRP2A51
KRP1B61
KRP1B61
EKRP1B2
KRP1B56
EKRP1B2
EKRP1B2
EKRP1B2
EKRP1B2
-
-
-
-
-
-
-
-
-
-
EKMTAC
DTA114A61
DTA114A61
DTA114A61
DTA114A61
DTA114A61
DTA104A61
DTA104A61
DTA104A61
DTA104A53
DTA104A61
DTA104A61
DTA104A61
DTA104A61
-
-
-
KRP1B101
tbc
tbc
tbc
tbc
Standard
Standard
Standard
-
Standard
Standard
Standard
Standard
Standard
Standard
Standard
-
Standard
Standard
Standard
Standard
-
-
-
KJB212A
KJB212A
KJB212A
KJB212A
KJB212A
-
-
-
KJB311A
KJB311A
KJB311A
KJB311A
KJB311A
-
-
-
-
KJB411A
KJB411A
KJB411A
KJB411A
-
-
-
-
BRP7A51
BRP7A51
BRP7A51
BRP7A51
BYK45F
BYK71F
-
-
BYBS32D
BYBS45D
BYBS71D
BYBS125D
-
-
-
-
tbc
tbc
tbc
tbc
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
tbc
tbc
tbc
tbc
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Standard
Standard
KDAJ25K56
standard
Standard
Standard
Standard
Standard
-
-
-
-
-
-
-
-
-
-
-
KEK26-1A
-
-
-
-
*Note: blue cells contain preliminary data
451
Options & accessories -
indoor
Ceiling s
FXMQ 50~80
FXMQ 100~125
Large
FXMQ 200~250
t
t*4
t
t*4
t
t*4
t
t*4
t
t*4
BRC4C65
BRC4C65
BRC4C65
BRC7G53
BRC7G53
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
-
-
-
-
t
t
t
t
t
t
t
t
KRCS01-4
KRCS01-4
KRCS01-1
KRCS01-4
KRCS01-4
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
Wiring adapter for external monitoring/control via dry contacts and
setpoint control via 0-140Ω
KRP4A51
KRP4A51
KRP4A51
KRP4A52
KRP4A52
Wiring adapter for external central monitoring/control
(controls 1 entire system)
KRP2A51
KRP2A51
KRP2A51
KRP2A62
KRP2A62
Wiring adapter with 4 output signals
(Compressor / Error, Fan, Aux. heater, Humidifier output)
EKRP1B2
EKRP1B2
KRP1B61
-
-
-
-
-
KRP1B54
KRP1B54
BRC1E52A/B
Premium wired remote control with full-text interface and back-light
BRC1D52
Standard wired remote control with weekly timer
Infrared remote control including receiver
BRC2E52A
Simplified wired remote control for heat recovery system
BRC3E52A
Simplified wired remote control for heat pump system
DCS302C51
Central remote control
DCS301B51
Unified ON/OFF control
Adapters and control
DCS601C51
Schedule timer
DCM601A51
Intelligent Touch Controller
External wired temperature sensor
External wireless temperature sensor
Others
Wiring adapter with 2 output signals
(Compressor / Error, Fan output)
FXHQ 32A
FXHQ 63A
Adapter for multi-tenant applications
(24VAC PCB power supply interface)
DTA114A61
DTA114A61
-
-
-
External control adapter for outdoor unit
DTA104A61
DTA104A61
DTA104A61
DTA104A62
DTA104A62
Installation box / Mounting plate for adapter PCBs
(For units where there is no space in the switchbox)
KRP4A96
KRP4A96
-
KRP1D93A
KRP1D93A
Connector for forced-off contact
Standard
Standard
Standard
EKRORO4
EKRORO4
Connection to centralized control
Standard
Standard
Standard
-
-
Electrical box with earth terminal (2 blocks)
-
-
-
KJB212A
KJB212A
Electrical box with earth terminal (3 blocks)
-
-
-
KJB311A
KJB311A
Decoration panel
(obligatory for cassette units, optional for others, rear panel for FXLQ)
BYBS71D
BYBS125D
-
-
-
Kit for mounting of decoration panel direct onto unit
EKBYBSD
EKBYBSD
-
-
-
Panel spacer for reducing required installation height
-
-
-
-
-
Sealing kit for 3-directional or 2-directional air discharge
-
-
-
-
-
Decorationpanel for air discharge
-
-
-
-
KDDQ50A140
Fresh air intake kit
Air discharge adapter for round duct
-
-
-
KDDQ50A140
KDAJ25K71
KDAJ25K140
-
-
-
-
-
-
KAFP501A56
KAFP501A80
KDU50P140
Replacement long life filter
Drain pump kit
Standard
Standard
-
KDU50P60
Sensor kit
-
-
-
-
-
Noise filter (for electromagnetic use only)
-
-
-
KEK26-1
KEK26-1
L-type piping kit (for upward direction)
-
-
-
KHFP5M35
KHFP5N63
* Installation box is necessary for these adapters
* The BYCQDWW has white insulation
Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install
the BYCQDWW decoration panel in environments exposed to concentrations of dirt
* Not recommended because of the limitation of the functions
* To be able to control the BYCQDGW the controller BRCE is needed
* The BYCQDGW is not compatible with Mini VRV, Multi and Split Non-Inverter Outdoor units
* Option not available in combination with BYCQDGW
* Both parts of the fresh air intake are needed for each unit
* Sensing function not available
* Independently controllable flaps function not available
452
1-way blow
Options & accessories -
uspended units
Wall mounted units
Floor standing units
Free-standing
FXLQ 20~25
FXLQ 32~40
indoor
FXHQ 71~100A
4-way blow
FXUQ 71~100A
FXAQ 15~63
Concealed
FXNQ 20~63
t
t*4
t
t*4
t
t*4
t
t*4
t
t*4
t
t*4
t
t*4
BRC7G53
BRC7C58
BRC7EB518
BRC4C65
BRC4C65
BRC4C65
BRC4C65
-
-
-
-
-
-
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
KRCS01-4
KRCS01-4
KRCS01-1
KRCS01-1
KRCS01-1
KRCS01-1
KRCS01-1
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
KRP4A52
KRP4A53 *2
KRP4A51
KRP4A51
KRP4A51
KRP4A51
KRP4A51
KRP2A62
-
KRP2A51
KRP2A51
KRP2A51
KRP2A51
KRP2A51
-
-
-
KRP1B61
KRP1B61
KRP1B61
KRP1B61
KRP1B54
-
-
-
-
-
-
FXLQ 50~63
-
-
DTA114A61
EKMTAC
EKMTAC
EKMTAC
EKMTAC
DTA104A62
-
DTA104A61
-
-
-
-
KRP1D93A
KRP1B97
KRP4A93
-
-
-
-
EKRORO4
EKRORO5
Standard
Standard
Standard
Standard
Standard
-
-
Standard
Standard
Standard
Standard
Standard
KJB212A
KJB212A
-
-
-
-
-
KJB311A
KJB311A
-
-
-
-
-
-
-
-
-
EKRDP25A
EKRDP40A
EKRDP63A
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
KDBHP49B140
-
-
-
-
-
-
KDBTP49B140
-
-
-
-
-
KDDQ50A140
-
-
-
-
-
-
-
-
-
-
-
-
-
KAFP501A160
KAFP551K160
-
-
-
-
-
KDU50P140
-
K-KDU572EVE
-
-
-
-
-
-
-
-
-
-
-
KEK26-1
-
-
-
-
-
-
KHFP5N160
-
-
-
-
-
-
*Note: blue cells contain preliminary data
453
Options & accessories - Ventilation & hot water
VAM150FA
VAM250FA
VAM350FB
VAM500FB
VAM650FB
EN779 Medium M6
-
-
EKAFV50F6
EKAFV50F6
EKAFV80F6
EN779 Fine F7
-
-
EKAFV50F7
EKAFV50F7
EKAFV80F7
EN779 Fine F8
-
-
EKAFV50F8
EKAFV50F8
EKAFV80F8
Model name
-
-
-
KDDM24B50
KDDM24B100
Nominal pipe Diameter (mm)
-
-
-
200
200
-
-
BRYMA65
BRYMA65
BRYMA65
VH1B
VH2B
VH2B
VH3B
VH3B
Dust filters
Silencer
CO2 sensor
VH electrical heater for VAM
Individual control systems
Wired remote control
VAM wired remote control
VAM-FA/FB
VKM-GB(M)
BRC1E52A/B / BRC1D52
BRC1E52A/B / BRC1D52
BRC301B61
-
VAM-FA/FB
VKM-GB(M)
Centralised remote control
Centralised control systems
DCS302C51
DCS302C51
Unified ON/OFF control
DCS301B51
DCS301B51
Schedule timer
DST301B51
DST301B51
Others
Wiring adapter for electrical appendices (note 6)
VAM150-250FA
VAM350-2000FB
VKM-GB(M)
KRP2A51
KRP2A51 (note 3)
BRP4A50A (note 4/5)
Adapter PCB for humidifier
KRP50-2
BRP4A50A (note 4/5)
BRP4A50A (note 4/5)
Adapter PCB for 3rd party heater
BRP4A50
BRP4A50A (note 4/5)
BRP4A50A (note 4/5)
-
-
-
Remote sensor
Notes
(1) Cool/heat selector required for operation
(2) Do not connect the system to DIII-net devices (Intelligent controller, Intelligent Manager, LonWorks interface, BACnet interface…).
(3) Installation box KRP1BA101 needed.
(4) Fixing plate EKMPVAM additionally needed for VAM1500-2000FB.
(5) 3rd party heater and 3rd party humidifier cannot be combined
(6) For external control and monitoring (ON/OFF control, operation signal, error indication)
VH electrical heater for VAM
220/250V ac 50/60 Hz. +/-10%
19A at 40°C (ambient)
5k ohms at 25°C (table 502 1T)
0 to 40°C / (0-10V 0-100%)
Adjustable from 1 to 2 minutes (factory set at 1.5 minutes)
20 X5 mm 250 m A
Supply voltage
Output current (maximum)
Temperature sensor
Temperature control range
Run on timer
Control fuse
LED indicators
Power ON - Yellow
Heater ON - Red (solid or flashing, indicating pulsed control)
Airflow fault - Red
98mm X 181mm centres 5 mm ø holes
35°C (during operation)
100°C Pre-set
125°C Pre-set
1A 120V AC or 1A 24V DC
0-10VDC
Mounting holes
Maximum ambient adjacent to terminal box
Auto high temp. cutout
Man. reset high temp. cutout
Run relay
BMS setpoint input
Vh electrical heater for vam
Capacity
Duct diameter
Connectable VAM
454
kW
mm
vH1B
VH2B
VH3B
VH4B
VH4/AB
VH5B
1
100
VAM150FA
-
1
150
VAM250FA
VAM350FB
1
200
VAM500FB
VAM650FB
1.5
250
VAM800FB
VAM1000FB
2.5
250
VAM800FB
VAM1000FB
2.5
350
VAM1500FB
VAM2000FB
Options & accessories - Ventilation & hot water
VAM800FB
VAM1000FB
VAM1500FB
VAM2000FB
VKM50GB(M)
VKM80GB(M)
VKM100GB(M)
EKAFV80F6
EKAFV100F6
EKAFV100F6 x2
EKAFV100F6 x2
-
-
-
EKAFV80F7
EKAFV100F7
EKAFV100F7 x2
EKAFV100F7 x2
-
-
-
EKAFV80F8
EKAFV100F8
EKAFV100F8 x2
EKAFV100F8 x2
-
-
-
KDDM24B100
KDDM24B100
KDDM24B100 x2
KDDM24B100 x2
-
KDDM24B100
KDDM24B100
250
250
250
250
-
250
250
BRYMA100
BRYMA100
BRYMA200
BRYMA200
BRYMA65
BRYMA100
BRYMA200
VH4B / VH4/AB
VH4B / VH4/AB
VH5B
VH5B
-
-
-
EKEQFCB 2
EKEQDCB 2
EKEQMCB 2
BRC1E52A/B / BRC1D52
BRC1E52A/B / BRC1D52 1
BRC1E52A/B / BRC1D52 1
-
-
-
EKEQFCB 2
EKEQDCB 2
EKEQMCB 2
-
-
-
-
-
-
-
-
-
EKEQFCB 2
EKEQDCB 2
EKEQMCB 2
-
-
-
-
-
-
-
-
KRCS01-1
Drain pan
Digital I/O PCB
Demand PCB - Required to connect room thermostat
Remote user interface (remocon) - Same controller as supplied with cascade unit
can be mounted parallel or on other location. If 2 controllers are installed, the
installer needs to select 1 master & 1 slave
Back-up heater
Wired room thermostat - Requires demand PCB EKRP1AHTA
Wireless room thermostat - Requires demand PCB EKRP1AHTA
Remote sensor for room thermostat - Requires demand PCB EKRP1AHTA
Domestic hot water tank - standward
(stacked on top of hydrobox)
Domestic hot water tank - with possibility for solar connection
HXY080-125A
HXHD125A
EKHBDPCA2
EKRP1HBAA
EKRP1AHTA
-
EKRUAHTB
-
EKBUHAA6(W1/V3)
EKRTWA
EKRTR1
EKRTETS
EKHTS200AC
EKHTS260AC
EKHWP500B
EKSV26P (vertical)
EKSH26P (horizontal)
EKSRPS
-
Solar collector *1
-
Pump station
-
*1 pump station is necessary for this option
455
Options - Chillers
Options - Small chillers
Integrated hydronics
Chiller series
EWAQ-ADVP
EWYQ-ADVP
EWAQ-ACV3
EWAQ-ACW1
EWYQ-ACV3
EWYQ-ACW1
EWWP-KBW1N
EWLP-KBW1N
LWE
Electrical
Single pump
High Glycol
Low Glycol
Evaporator heater tape
OPSP
STD
STD
STD
STD
STD
STD
OPZH
OPZL
OP10
STD
STD
STD
STD
STD
STD
Option
Option
Option
Option
(s) OP12 & OP03 need to be added to meet Swedish national law 1992: 16
(1) Impossible option combination: OPZH+OPZL
Options - Medium and large chillers (Part 1)
Description
Total heat recovery
Total heat recovery (1 circuit)
Partial heat recovery
Direct on line starter (DOL)
Wye-Delta compressor starter (Y-D)
Soft starter
Heat pump version
Heat pump version (including pursuit mode)
Brine version (down -8°C)
Brine version (down -10°C)
Brine version (down -15°C)
Double setpoint
Compressor thermal overload relays
Fans thermal relays
Phase monitor
Inverter compressor starter
Under / Over voltage control
Energy meter
Energy meter (including current limit)
Capacitors for power factor correction
Auxiliary relay
Current limit
Evaporator victaulic kit
Evaporator flange kit
Evaporator marine waterbox victaulic (2 passes)
Evaporator marine waterbox victaulic (1 pass)
Evaporator marine waterbox victaulic (3 passes)
Evaporator marine waterbox flanged (2 passes)
Evaporator marine waterbox flanged (1 pass)
Evaporator marine waterbox flanged (3 passes)
Condenser double flanges kit
Evaporator water side design pressure (10 Bar)
Evaporator water side design pressure (16 Bar)
20mm evaporator insulation
Axial fans (100 Pa lift)
McQuiet
Axial fans (250 Pa lift)
20mm condenser insulation
Fan silent mode
Fans Speed Control Device (Phase Cut)
Condenser victaulic kit
Condenser flange kit
Condenser marine waterbox victaulic (2 passes)
Condenser marine waterbox victaulic (1 pass)
Condenser marine waterbox victaulic (3 passes)
Condenser marine waterbox flanged (2 passes)
Condenser marine waterbox flanged (1 pass)
Condenser marine waterbox flanged (3 passes)
Speedtrol (fan speed control device - ON/OFF - up to -18°C)
Speedtrol (fan speed control device - ON/OFF - down to -10°C in cooling)
Condenser coil guards
Evaporator area guards
Cu-Cu condenser coil
Cu-Cu-Sn condenser coil
456
EWAQ-EEWAQ~BAW EWAQ-E-XS
XL/XR
Code
EWYQ-F-XS EWYQ-F-XL EWYQ-F-XR EWAD-E- EWAD-D-SS EWAD-D-SL
EWYQ~BAW EWAQ-F-SS/XS EWAQ-F-SL/
SR/XL/XR
01
Option Option Option
02
Option Option
03
Option Option
CF
CF
CF
Option Option Option
04
STD
STD
STD
STD
STD
05
STD
STD
STD
06
Option Option Option Option Option Option Option Option
07
07a
08a (1)
08b (1) Option
08c (1)
Option Option Option Option Option Option Option Option
10
STD
STD
STD
STD
STD
STD
STD
STD
11
Option Option Option Option Option Option Option Option
12
13
Option Option Option Option Option
STD
STD
STD
14
Option(4) Option(4)
15
Option Option Option Option Option Option Option Option
16
Option Option Option Option Option Option Option Option
16a
17
Option Option Option Option Option Option Option Option
18
19
Option Option Option
20
STD
STD
STD
STD
STD
STD
21
Option
22
22a
23
24
24a
25
26
27
STD
STD
28
29
STD
STD
STD
STD
STD
Option Option
STD
30
31
32
CF
CF
CF
33
34
35
36
37
38
38a
39
40
40a
41
42
Option Option
Option Option Option
42a
Option Option
43
Option Option Option Option Option Option Option Option
44
Option Option Option Option Option
45
Option Option Option Option Option Option Option Option
46
Option Option Option Option Option Option Option Option
EWAD-D-SR EWAD-D-SX EWAD-D-XS EWAD-D-XR EWAD-D-HS
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
STD
Option
STD
Option
STD
Option
STD
Option
STD
Option
Option
STD
Option
Option
STD
Option
Option
STD
Option
Option
STD
Option
Option
STD
Option
STD
STD
STD
STD
STD
Option(4) Option(4) Option(4) Option(4) Option(4)
Option Option Option Option Option
Option Option Option Option Option
Option
Option
Option
Option
Option
Option
Option
STD
Option
Option
STD
Option
Option
STD
Option
Option
STD
STD
STD
STD
STD
STD
Option
Option
Option
STD
CF
CF
CF
CF
CF
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
EWAD-C-
EWAD-CZ
EWAD-TZ
Option
Option
Option
Option
Option
Option
EWAQ-GZ
EWYQ-GZ
EWYD-BZSS EWYD-BZSL
Option
Option
STD
Option
Option
ERAD-E-
EWWQ-B-
EWWD-J-SS
Option
STD
Option
Option
EWAD-CF
Option
Option
Option
Option
Option
Option
EWWD-G-
EWWD-I-SS EWWD-I-XS EWWD-H-XS EWLD-J-SS EWLD-G-SS EWLD-I-SS EWWD-FZXS
Option
Option
Option
Option
Option
Option
Option
STD
Option
STD
Option
STD
Option(4)
STD
Option
STD
Option
STD
Option
Option
Option
Option
Option
Option
Option
Option
Option
STD
Option
Option
STD
Option(4)
STD
Option
STD
Option
Option
Option
NC-SO
Option
Option
Option
STD
Option
STD
Option
STD
Option
STD
STD
STD
STD
STD
STD
STD
Option
STD
STD
STD
Option
STD
Option
STD
Option
STD
Option
STD
Option
STD
Option
STD
Option
STD
STD
STD
Option
Option
STD
STD
STD
Option
Option
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
Option
Option
Option
Option
STD
STD
Option
Option
STD
Option
Option
STD
STD
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
STD
Option
STD
Option
STD
Option
STD
Option
STD
Option
STD
Option
STD
Option
STD
Option
Option
STD
Option
Option
Option
Option
STD
Option
Option
Option
STD
Option
Option
STD
Option
STD
STD
Option
STD
Option
STD
Option
STD
STD
STD
STD
Option
Option
CF
Option
Option
STD
STD
STD
STD
STD
STD
Option
Option
Option
STD
Option
Option
STD
Option
STD
Option
STD
Option
STD
Option
STD
Option
Option
Option
STD
Option
Option
Option
Option
Option
Option
Option
Option
STD
Option
Option
Option
STD
STD
Option
Option
CF
STD
STD
STD
Option
STD
Option
Option
STD
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
457
Options - Medium and large chillers (Part 2)
Description
Code
Condenser water side design pressure (16 Bar)
47
Condenser water side design pressure (10 Bar)
47a
Alucoat fins coil
49
Cu-Ni 90-10 condenser tubes
50
Condenser 1 pass (ΔT 4-8 °C)
51
Condenser 2 passes (ΔT 4-8 °C)
52
Condenser 2 passes (ΔT 9-15 °C)
53
Condenser 4 passes
54
Water pressure differential switch on condenser
55
Water pressure differential switch on evaporator
56
Evaporator electric heater
57
Evaporator flow switch
58
Condenser flow switch
59
Electronic expansion valve
60
Discharge line shut-off valve
61
Suction line shut-off valve
62
High pressure side manometers
63
Low pressure side manometers
64
Ambient outside temperature sensor and setpoint reset
67
Hour run meter
68
General fault contactor
69
Container Kit
71
Rubber anti vibration mounts
75
Sound proof system
76
Sound proof system (integral)
76-a
Sound proof system (compressor)
76-b
Spring anti vibration mounts
77
One centrifugal pump (low lift)
78
One centrifugal pump --- SPK1
78-a
One centrifugal pump --- SPK2
78-b
One centrifugal pump --- SPK3
78-c
One centrifugal pump --- SPK4
78-d
One centrifugal pump --- SPK5
78-e
One centrifugal pump --- SPK6
78-f
One centrifugal pump --- SPK7
78-g
One centrifugal pump --- SPK8
78-h
One centrifugal pump --- SPK9
78-i
One centrifugal pump --- SPK10
78-j
One centrifugal pump --- SPK1a
78-l
One centrifugal pump --- SPK1b
78-m
One centrifugal pump --- SPK1c
78-n
One centrifugal pump (high lift)
79
Two centrifugal pump (low lift)
80
Two centrifugal pump --- DPK1
80-a
Two centrifugal pump --- DPK2
80-b
Two centrifugal pump --- DPK3
80-c
Two centrifugal pump --- DPK4
80-d
Two centrifugal pump --- DPK5
80-e
Two centrifugal pump --- DPK6
80-f
Two centrifugal pump --- DPK7
80-g
Two centrifugal pump --- DPK8
80-h
Two centrifugal pump (high lift)
81
Witness test
82
External tank without cabinet (500 L)
83 (3)
External tank without cabinet (1000 L)
84 (3)
External Tank (500 L) With CABINET RAL 7042
85
External Tank (1000 L) With CABINET RAL 7042
86
External tank with cabinet (500 L)
87 (3)
External tank with cabinet (1000 L)
88 (3)
Acoustic test
89
Setpoint reset, Demand limit and Alarm from external device
90
Double pressure relief valve with diverter
91
PW COMPRESSOR - PART WINDING START
92
Low ambient kit for 1 circuit
93
Low ambient kit for 2 circuits
94
Compressors circuit breakers
95
Fans circuit breakers
96
Main switch interlock door
97
Emergency stop
98
Fans speed regulation (+ fan silent mode)
99 (2)
Fans speed regulation (inverter)
99a (2)
Refrigerant recovery unit
100
Evaporator right water connections
101
Ground fault relay
102
Evaporator 1 pass
103
Evaporator 2 passes
103a
Evaporator double flange kit
104
Liquid receiver
105
Evaporator right water connections
106
Rapid restart
110
High temperature kit
111
Transport kit
112
Optimized free cooling (VFD fans regulation)
113-a
Optimized free cooling (On/Off fans)
113-b
Nordic kit
114
Water filter
115
Condenser coil protection panels
116
Blygold coil treatment
117
Inverter kit for pump (SPK1-SPK6)
120a
Inverter kit for pump (SPK7-SPK10)
120b
120c
Inverter kit for pumps (DPK2-DPK6)
Inverter kit for pumps (DPK7-DPK10)
120d
Refrigerant leak detection
121
EWAQ~BAW EWAQ-E-XS EWAQ-E-XL/XR
EWAQ-F-SL/ EWYQ-F-XS
EWYQ~BAW EWAQ-F-SS/XS XR/XL/XR
Option
Option
EWYQ-F-XL
EWYQ-F-XR
EWAD-E-
EWAD-D-SS
EWAD-D-SL
EWAD-D-SR
EWAD-D-SX
EWAD-D-XS
EWAD-D-XR
Option
Option
STD
STD
STD
Option
Option
Option
Option
Option
Option
Option
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
Option
STD
Option
STD
STD
Option
STD
STD
Option
STD
Option
STD
Option
STD
Option
STD
Option
Option
Option
Option
STD
STD
STD
Option
Option
STD
Option
Option
Option
Option
STD
STD
STD
Option
Option
STD
Option
Option
Option
Option
STD
STD
STD
Option
Option
STD
Option
Option
Option
Option
STD
STD
STD
Option
Option
STD
Option
Option
Option
Option
STD
STD
STD
Option
Option
STD
STD
STD
Option
Option
STD
STD
STD
Option
Option
STD
STD
STD
Option
Option
STD
STD
STD
Option
Option
STD
STD
STD
Option
Option
STD
STD
STD
Option
Option
STD
STD
STD
Option
Option
STD
STD
STD
Option
Option
STD
STD
STD
Option
Option
STD
STD
STD
Option
Option
STD
STD
STD
Option
Option
STD
STD
STD
Option
Option
STD
STD
STD
Option
Option
STD
STD
STD
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
STD
Option
STD
Option
STD
Option
STD
Option
STD
Option
STD
Option
STD
Option
Option
Option
STD
Option
Option
STD
Option
Option
STD
Option
Option
STD
Option
Option
STD
Option
STD
STD
Option
STD
STD
Option
STD
STD
Option
STD
STD
Option
STD
STD
Option
STD
STD
Option
STD
STD
Option
Option
Option
Option
STD
Option
Option
Option
Option
STD
Option
Option
Option
Option
Option
Option
Option
SO
SO
SO
SO
SO
SO
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
STD
Option
Option
STD
Option
Option
Option
STD
Option
Option
Option
STD
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
STD
Option
Option
(1) Option 08 includes option 29 - (2) Option 99(a) includes ‘Fan overload protection’ - (3) Piping between the inertial tank and the unit is not included. Electric heater power supply has to be provided from external source (4) The order of inverter compressor will have an impact on the delivery time: please contact the factory - (5) Unit performance will be affected; contact factory for information. It is mandatory to order the option 26 when selecting CU-Ni 90-10 condenser tubes - (6)
Sound proof system - compressor enclosure - (7) Compressor enclosure - (8) Soundproof cabinet will be supplied in a separate kit and not assembled. For better performance the cabinet will be integral kind (around the whole chiller, not only around compressors).
Cabinet assembly is not included in the supply (9) Special transport is required (flat rack truck and open top when option 01 is selected) for model sizes as follows: EWWDC12I-SS - EWWDC18I-SS (10) Forklift loading-unloading operations are not allowed when option 01
458
EWAD-D-HS
Option
EWAD-C-
Option
EWAD-CZ
Option
EWAD-TZ
EWAQ-GZ
Option
STD
STD
Option
STD
Option
STD
Option
STD
Option
STD
STD
STD
Option
Option
STD
STD
STD
Option
Option
STD
STD
Option
Option
Option
STD
STD
STD
Option
Option
STD
STD
STD
Option
Option
STD
STD
STD
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
EWYQ-GZ
STD
STD
STD
STD
STD
STD
STD
STD
Option
Option
STD
STD
STD
Option
Option
STD
Option
Option
Option
Option
STD
STD
STD
Option
Option
Option
EWAD-CF
Option
EWYD-BZSS EWYD-BZSL
Option
Option
STD
Option
STD
Option
STD
Option
STD
Option
Option
Option
Option
STD
STD
STD
Option
Option
STD
STD
Option
Option
Option
STD
STD
STD
STD
STD
STD
Option
Option
STD
STD
STD
Option
Option
STD
STD
STD
Option
Option
STD
STD
STD
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
ERAD-E-
Option
EWWQ-B-
EWWD-J-SS
EWWD-G-
STD
STD
STD
Option
Option
Option
STD
STD
Option
STD
STD
STD
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
STD
Option
STD
STD
Option
STD
STD
Option
STD
Option
Option
SO
STD
Option
STD
Option
STD
Option
STD
Option
Option
Option
STD
Option
Option
STD
STD
Option
STD
STD
STD
Option
Option
STD
STD
STD
Option
Option
STD
STD
Option
STD
STD
Option
STD
STD
Option
STD
STD
STD
STD
CF
SO
Option
CF
SO
Option
Option
Option
Option
STD (14)
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
STD (13)
Option
Option
Option
Option
Option
Option
Option
STD
Option(5) Option (5) Option (5) Option (5) Option (5)
STD
STD
NC-SO
STD
STD
STD
NC-SO
NC-SO
Option
Option
Option
Option
STD
Option
Option
Option
Option
STD
STD
STD
Option
Option
STD
STD
STD
Option
Option
STD
Option
Option
Option
Option
STD
STD
Option(11)
Option
STD
STD
Option
Option
STD
STD
Option
Option
STD
STD
Option (9)
Option
Option (6) Option (7)
Option (5)
STD
Option (5)
STD
STD
STD
STD
Option
Option
STD
Option
Option
Option
Option
Option
Option
STD
STD
Option
Option
Option
STD
STD
STD
Option
Option
STD
STD
STD
Option
Option
STD
Option
Option
Option
Option
STD
STD
Option
Option
STD
STD
Option
Option
STD
STD
Option
Option
STD
STD
STD
STD
Option Option(11)
Option
Option
Option (8) Option (8) Option (8)
Option (6) Option (7)
Option
Option
STD
Option
Option
Option
STD
STD
Option
Option
Option (8) Option (8)
Option
Option
Option
Option
STD
Option
Option
Option
Option
SO
STD
Option
Option
Option
Option
Option
STD
STD
Option (8)
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
EWWD-I-SS EWWD-I-XS EWWD-H-XS EWLD-J-SS EWLD-G-SS EWLD-I-SS EWWD-FZXS
Option
Option
SO
Option
STD
Option
STD
Option
STD
Option
STD
Option
STD
Option
Option
STD
Option
Option
STD
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
STD
Option
STD
Option
STD
Option
STD
STD
Option
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
STD
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
Option
NC-SO
STD
Option
Option
Option
Option
Option
Option
Option Option(12) Option
Option
Option(10)
Option
Option
Option
Option
Option
Option(12)
Option
Option
STD
STD
NC-SO
STD
Option
Option
Option
Option
is selected for model sizes as follows: EWWDC12I-SS - EWWDC18I-SS - (11) Special Transport is required (flat rack truck and open top) for model sizes as follows: EWLDC10I-SS - EWLDC17I-SS or EWWQC11B-SS - EWWQC20B-SS or EWWQC10B-XS, EWWQC12B-XS - EWWQC21B-XS
- (12) Forklift loading-unloading operations are not allowed for model sizes as follows: EWLDC10I-SS - EWLDC17I-SS or EWWQC11B-SS - EWWQC20B-SS or EWWQC10B-XS, EWWQC12B-XS - EWWQC21B-XS - (13) STD only for single circuit unit (14) STD only for Premium and High
efficiency version
CF = Contact the factory - STD = Standard - SO = Specify at Order entry - NC = No additional cost
459
Accessories - Chillers
Air cooled chillers
EWA/YQ009-011ACV3
EWA/YQ009-013ACW1
EWA/YQ~BA*
SEHVX+SERHQ
Panels
EKDSSP
EKDSSP-S***
EKDDSP
EKPWPRO
EKPWPROM
Serial Cards & Comm. Modules
EKAC10C
EKAC200J
EKACBAC
EKACLON
EKACLONP
EKACRS232
EKACWEB
EKACBACMSTP
EKACBACCERT
EKCM200J
EKCMLON
EKCMBACMSTP
EKCMBACIP
Other Systems & Accessories
RTD-W
EKCC-W
EKCON
EKCONUSB
EKMODEM
EKGSMOD
EKRP1HB
EKRUPCJ
EKRUPCS
EKPV2J
EKPWPROEXT
EKGWWEB
EKGWMODEM
EKRUMCA
EHMC*
EKRP1AHT
DTA104A62
EKRUAHTB
Gauges
BHGP26A1
EWAD-EERAD-E-
EWAD~D-
t
t
t
t
t
t
t
t
EWAD~C-
EWAD~CZ
EWAD~TZ
EWAD-CF
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
Soft starter
EKSS
* To install EKRUMCA => EKAC10C needs to be installed on the unit.
460
EWYD-BZ
* EKAC10C allows direct connection to MODBUS BMS system
t
t
t
t
t
Water cooled and condenserless chillers
EWAQ-E-/FEWYQ-F-
EWAQ-GZ
EWYQ-GZ
t
t
t
t
EWW(L)P-KBW1N
EWW(L)D~G-
EWW(L)D~I-
EWWD~H-
EWWQ~B-
EWW(L)D~J-
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
DWSC & DWDC
EWWD-FZXS
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t (014-045)
461
Accessories - Fan coil units
Network & control systems
FWM~D / FWL~D / FWV~D
Wired remot control (Standard)
FWEC1A
FWS~A / FWR~A / FWZ~A
-
Temperature sensor kit
FWTSKA
FWTSKA
Relative humidity sensor kit
FWHSKA
FWHSKA
Fan stop thermostat
YFSTA6
-
Master slave interface
EPIMSB6
-
Power interface
-
-
Optional PCB for MOD-bus connection
-
-
FWM~D / FWL~D / FWV~D
Valves
1
15
2
25
3
35
FWS~A / FWR~A / FWZ~A
4
6
8
10
2
3
6
8
3-ways 230V on/off valve kit (2-pipe)
E2MV03A6
E2MV06A6
E2MV10A6
E2MV03A6
E2MV10A6
3-ways 230V on/off valve kit (4-pipe)
E1MV03A6
E4MV06A6
E4MV10A6
E4MV03A6
E4MV10A6
E2MV2B10A6
E2MV2B07A6
E2MV2B10A6
2-ways 230V on/off valve kit
(cooling heat exchanger)
E2MV2B07A6
2-ways 230V on/off valve kit
(additional heat exchanger)
E2MV2B07A6
E2MV2B07A6
Simplified 3-ways 230V on/off valve kit (2-pipe)
E2MVD03A6
E2MVD06A6
E2MVD10A6
E2MVD03A6
E2MVD06A6 E2MVD10A6
Simplified 3-ways 230V on/off valve kit (4-pipe)
E4MVD03A6
E4MVD06A6
E4MVD10A6
E4MVD03A6
E4MVD06A6 E4MVD10A6
3-ways 24V on/off valve kit (2-pipe)
E2M2V03A6
E2M2V06A6
E2M2V10A6
E2M2V03A6
E2M2V06A6 E2M2V10A6
3-ways 24V on/off valve kit (4-pipe)
E4M2V03A6
E4M2V06A6
E4M2V10A6
E4M2V03A6
E4M2V06A6 E4M2V10A6
3-ways proportional valve kit (2-pipe)
E2MPV03A6
E2MPV06A6
E2MPV10A6
-
3-ways proportional valve kit (4-pipe)
2-ways 24V on/off valve kit
(cooling heat exchanger)
2-ways 24V on/off valve kit
(additional heat exchanger)
2-ways proportional valve kit
(cooling heat exchanger)
2-ways proportional valve kit
(additional heat exchanger)
3-ways 230V on/off valve kit
(additional heat exchanger)
2-ways 230V on/off valve kit (2-pipe)
E4MPV03A6
E4MPV06A6
E4MPV10A6
-
E2M2V210A6
E2M2V207A6
E2M2V207A6
E2M2V207A6
E2MPV207A6
2-ways 230V on/off valve kit (4-pipe)
Panels + valve
Decoration panel 600x600 (2-pipe)
Decoration panel + wireless controller
3-ways on/off valve
462
E2M2V207A6
E2MPV210A6
-
E2MPV207A6
-
-
-
-
-
-
-
FWF~C
FWG~AT
FWG~AF
All sizes
All sizes
All sizes
DCP600TC
-
-
-
DCP900BTA
DCP900BFA
MCKCW2T3VN
MCKEW2T3VN
MCKEWH4T3VN
E2M2V210A6
Accessories - Fan coil units
FWD~A
FWB~B
FWP~A
FWE ~C
FWT~CT
FWF~CT
FWG~A
FWEC1A
FWEC1A
-
FWEC1A
-
-
BRD51A61
FWTSKA
FWTSKA
FWTSKA
FWTSKA
-
-
-
FWHSKA
FWHSKA
FWHSKA
FWHSKA
-
-
-
YFSTA6
YFSTA6
-
-
-
-
-
EPIMSB6
EPIMSB6
-
EPIMSB6
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
EPIB6
-
FWD~A
4
6
8
10
FWB~B
12
16
18
2-4
5-7
FWP~A
8-10
2-4
5-7
FWE~C
FWC~B
FWF~B
All sizes
All sizes
All sizes
EKMV3C09B
EKMV3C09B
ED2MV04A6
ED2MV10A6
ED2MV12A6
ED2MV18A6
-
-
EK2MV3B10C5
ED2MV04A6
ED2MV10A6
2x ED2MV12A6
2xED2MV18A6
-
-
EK4MV3B10C5
2 xEKMV3C09B 2 x EKMV3C09B
-
E2MV207A6
E2MV210A6
E2MV207A6
-
-
-
-
E2MV207A6
E2MV210A6
E2MV207A6
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
E2MV307A6
-
-
-
EKMV2C09B
EKMV2C09B
-
E2MV307A6
E2MV310A6
-
-
-
EK2MV2B10C5
-
-
-
EK4MV2B10C5
2 xEKMV2C09B 2 xEKMV2C09B
463
Accessories - Fan coil units and air handling units
FWM~D / FWL~D / FWV~D
Other accessories
Electric heater (Standard)
1
15
EEH01A6
2
EEH02A6
25
3
35
EEH03A6
Electric heater (Big)
FWS~A /FWR~A / FWZ~A
4
6
8
10
2
3
EEH06A6
EEH10A6
EEH02A6
EEH03A6
EFA02A6
-
Fresh air intake
-
EFA02A6
EFA03A6
EFA06A6
EFA10A6
Additional heat exchanger
ESRH02A6
ESRH03A6
ESRH06A6
ESRH10A6
ESRH02A6 ESRH03A6
Air intake & discharge grille
EAIDF02A6
EAIDF03A6
EAIDF06A6
EAIDF10A6
EAIDF02A6 EAIDF03A6
Rear panel
ERPV02A6
ERPV03A6
ERPV06A6
ERPV10A6
ERPV02A6 ERPV03A6
Supporting feet
ESFV06A6
Supporting feet & grille
Plenum box with circular connections
ESFV10A6
EFA03A6
ESFV06A6
ESFVG02A6
ESFVG03A6
ESFVG06A6
ESFVG10A6
ESFVG02A6 ESFVG03A6
EPCC02A6
(only for FWM-D)
EPCC03A6
(only for FWM-D)
EPCC06A6
(only for FWM-D)
EPCC10A6
(only for FWM-D)
EPCC02A6
EPCC03A6
(only for FWS-A) (only for FWS-A)
Vertical auxiliary drainpan
EDPVB6
EDPVB6
Horizontal auxiliary drainpan
EDPHB6
EDPHB6
Mechanical options
FWC~BT/BF
Decoration Panel - Standard (Round flow)
BYCQ140CW1
-
BYCQ140CW1W
-
Decoration Panel - White (Round flow)
Decoration Panel (4-way blow)
FWF~BT/BF
-
BYFQ60B3
KDBHQ55C140
KDBH44BA60
Long-life filter
KAFP551K160
KAFQ441BA60
Fresh air intake kit (20% fresh air) (Direct installation)
KDDQ55C140
-
-
KDDQ44XA60
KDBQ44B60
-
Sealing member of air discharge outlet
Fresh air intake kit (Direct installation)
Panel spacer
Control options
FWF~BT/BF
FWC~BT/BF
Infrared remote control (H/P)
BRC7E530
BRC7E532F
Infrared remote control (C/O)
BRC7E531
BRC7E533F
Remote sensor
KRCS01-1
KRCS01-4
Remote ON / OFF
EKROROA
-
Control options
FWF~BT/BF - FWC~BT/BF
Remote control wired
BRC315D7
Central remote control
DCS302CA51
Intelligent touch controller
DCS601C51C
Unified ON/OFF controller
DCS301BA51
Electrical installation box with earth terminal (2 blocks)
KJB212A
Electrical installation box with earth terminal (3 blocks)
KJB311A
Electrical installation box
KJB411A
Schedule timer
Wiring adapter for electrical appendices
DST301BA51
KRP4AA53
Wiring adapter for electrical appendices
KRP2A52
Noise filter (for electromagnetic interface use only)
KEK26-1A
Installation box for adaptor PCB
KRP1BA101
Installation box for adaptor PCB
Optional PCB for MOD-bus connection
KRP1H98
EKFCMBCB7
2-way valve - On / Off
EKMV2C09B7
3-way valve - On / Off
EKMV3C09B7
Valve control PCB
464
EKRP1C11
Accessories - Fan coil units and air handling units
FWS~A / FWR~A / FWZ~A
FWD~A
6
8
10
EEH06A6
EEH10A6
EDEH04A6 EDEHS06A6
EDEH04A6 EDEHB06A6
EDEHB10A6
EFA06A6
EFA10A6
EDMFA04A6 EDMFA06A6
EDMFA10A6
ESRH06A6
ESRH10A6
-
EAIDF06A6
EAIDF10A6
-
-
-
ERPV06A6
ERPV10A6
-
-
-
ESFV10A6
-
-
-
ESFVG06A6 ESFVG10A6
-
-
-
EPCC06A6
EPCC10A6
(only for FWS-A) (only for FWS-A)
-
-
-
EDEHS10A6
12
16
EDEHS12A6
18
2-4
FWP~A
8
-
4
FWB~B
6
5-7
8-10
2-4
5-7
EDEHS18A6
Factory mounted
Factory mounted
EDEHB12A6
EDEHB18A6
-
-
EDMFA12A6
EDMFA18A6
EAH04A6
EAH07A6
EAH10A6
EAH04A6
EAH07A6
EDPVB6
EDDPV10A617
EDDPV18A617
-
-
EDPHB6
EDDPH10A621
EDDPH18A621
-
-
D-AHU Professional
Construction type
Aluminium
Profile
Panel insulation
External sheet
material
FP 25
standard
option
option
option
option
option
option
option
option
option
option
option
option
Glass fibre reinforced nylon
standard
standard
standard
standard
Polyurethane foam density 45 kg/m3 thermal
conductivity 0.020 W/m*K fire reaction class 1
standard
standard
standard
standard
option
option
option
option
Mineral wool density 90 kg/m3 thermal
conductivity 0.037 W/m*K (referred to 20°C) fire
reaction class 0
Grey Plastisol covered galvanized steel
standard
standard
standard
standard
Pre-coated galvanized steel
option
option
option
option
Galvanized steel
option
option
option
option
Aluminium
option
option
option
option
AISI 304 stainless steel
Pre-coated galvanized steel
Internal sheet material Grey Plastisol covered galvanized steel
Aluminium
AISI 304 stainless steel
Aluminium
Base frame
Galvanized steel
Glass fibre reinforced nylon
Compression type
Type
FP 50
standard
Aluminium with thermal break
Galvanized steel
Handle
SP 45
standard
Anodized aluminium
Anodized aluminium with thermal break
Corner
SP 65
standard
Hinge function type
(possibility to remove door)
option
option
option
option
standard
standard
standard
standard
option
option
option
option
option
option
option
option
option
option
option
option
option
standard
(from size 1 to size 17)
standard
(from size 18 to size 27)
standard
option
standard
(from size 1 to size 17)
standard
(from size 18 to size 27)
standard
option
standard
(from size 1 to size 17)
standard
(from size 18 to size 27)
standard
option
standard
(from size 1 to size 17)
standard
(from size 18 to size 27)
standard
standard
standard
standard
standard
option
option
option
option
D-AHU Easy
Construction type
Profile
Aluminium
Corner
Glass fibre reinforced nylon
Panel insulation
Polyurethane foam thermal conductivity 0.024 W/m*K
External sheet material
Internal sheet material
DS 50
DS 25
Standard
Standard
Standard
Standard
Standard (density 45 kg/m3)
standard (density 47 kg/m3)
Pre-coated galvanized steel (RAL 9002)
Standard
Standard
Galvanized steel
Standard
Standard
Base frame
Aluminium
Standard
Standard
Handle
Glass fibre reinforced nylon
Standard
Standard
Type
Compression type
Standard
Standard
465
Options - Refrigeration
Conveni-Pack
LRYEQ16AY1
Digital pressure gauge kit
Pressure gauge kit
Kit (Inlet + Outlet)
Air outlet
Snowbreak hood Left side air inlet
Right side aire inlet
Back side air inlet
Central drain pan kit
Communication box
Booster unit
Suction branch pipe for multi
BHGP26A1
KPS26C504
KPS26C504T
KPS26C504L
KPS26C504R
KPS26C504B
KWC26C450*
-
ZEAS
LREQ5BY1
LREQ6BY1
LREQ8BY1
LREQ12BY1
LREQ15BY1
LREQ20BY1
LREQ15BY1Rx2 LREQ20BY1Rx2
BHGP26A1
KHGP26B140
KPS26C160
KPS26C160T
KPS26C280
KPS26C280T
KPS26C504
KPS26C504T
KPS26C504L
KPS26C504R
KPS26C160B
KWC26C160
KPS26C280B
KPS26C280
BRR9A1V1
LCBKQ3AV19
-
* In cold areas should be heated by a field-supplied heater to prevent drain water from freezing in the drain pan.
*** software update required (to be executed during commissioning) **** mandatory
466
LREQ10BY1
Multi-ZEAS
** required for each module
KPS26C450
KPS26C504B
KPS26C450** x2
BRR9A1V1***
EKHRQZM****
Options - Control systems
DCM601A51
iTM plus adapter
iTM ppd software
iTM energy navigator software
iTM BACnet option
WAGO I/O
Modbus communication unit
DC24V power supply unit:
DC24V power supply unit:
Connector:
Terminator module:
Di module:
Do module:
Ai module:
Thermistor module:
Interface adapter for connection to RA units
Interface adapter for connection to R-407C/R-22 Sky Air units
Interface adapter for connection to R-410A Sky Air units
DIII board
Digital input/output
DCM601A52
DCM002A51
DCM008A51
DCM009A51
WGDCMCPLR
787-712
750-613
750-960
750-600
750-400, 750-432
750-513/000-001
750-454, 750-479
750-461/020-000
DMS504B51
DMS502A51
LonWorks Interface
BACnet Interface
KRP928A2S
DTA102A52
DTA112B51
KRP928A2S
DTA102A52
DTA112B51
DAM411B51
DAM412B51
467
Conversion table
refrigerant piping
Power supply
T1
V1
VE
V3
VM
W1
Y1
=
=
=
=
=
=
=
3~, 220V, 50Hz
1~, 220-240V, 50Hz
1~, 220-240V/220V, 50Hz/60Hz*
1~, 230V, 50Hz
1~, 220~240V/220~230V, 50Hz/60Hz
3N~, 400V, 50Hz
3~, 400V, 50Hz
inch
1
/4˝
3
/8˝
1
/2˝
5
/8˝
3
/4˝
7
/8˝
1 1/8˝
1 3/8˝
1 5/8˝
1 3/4˝
2˝
2 1/8˝
2 5/8˝
* For VE power supply only 1~, 220-240V, 50Hz data
is displayed in this catalogue.
mm
6.4 mm
9.5 mm
12.7 mm
15.9 mm
19.1 mm
22.2 mm
28.5 mm
34.9 mm
41.3 mm
44.5 mm
50.8 mm
54 mm
66.7 mm
Measuring conditions
Air conditioning
1) Nominal cooling capacities are based on:
Indoor temperature
Outdoor temperature
Refrigerant piping length
Level difference
2) Nominal heating capacities are based on:
Indoor temperature
Outdoor temperature
Refrigerant piping length
Level difference
27°CDB/19°CWB
35°CDB
7.5m - 8/5m VRV
0m
20°CDB
7°CDB/6°CWB
7.5m - 8/5m VRV
0m
Applied systems
Air cooled
Cooling only
Heat pump
Water cooled
Cooling only
Heating only
Condenserless chiller
Fan coil units
Cooling
Heating
Evaporator: 12°C/7°C
Evaporator: 12°C/7°C
Condenser: 40°C/45°C
Ambient: 35°CDB
Ambient: 35°C
Ambient: 7°CDB/6°CWB
Evaporator: 12°C/7°C
Condenser: 30°C/35°C
Evaporator: 12°C/7°C
Condenser: 40°C/45°C
Evaporator: 12°C/7°C
Condensing temperature: 45°C / liquid temperature: 40°C
Room temperature: 27°CDB /19°CWB
Water inlet/outlet temperature: 7°C/12°C
Room temperature: 20°C
2 pipe: Water inlet temperature: 50°C (same water flow as in cooling mode)
4 pipe: Water inlet/outlet temperature: 70°C/60°C
The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value,
depending on the distance and acoustic environment (for measuring conditions: please refer to the technical databooks).
The sound power level is an absolute value indicating the “power” which a sound source generates.
For more detailed information please consult our technical databooks.

Benefits
360°
We care icons
Econo mode
This function decreases the power consumption so that other
applicances that need large power consumption can be used.
This function is also energy saving.
Auto-cleaning filter
The filter automatically cleans itself once per day. Simplicity of
upkeep means optimum energy efficiency and maximum comfort
without the need for expensive or time-consuming maintenance.
Movement sensor
The sensor detects whether someone is in the room. When
the room is empty, the unit switches to economy mode after
20 minutes and restarts when a person enters the room.
Inverter technology
In combination with inverter controlled outdoor units
Home leave operation
During absence, the indoor temperature can be maintained at
a certain level.
2 area intelligent eye
Air flow is sent to a zone other than where the person is
located at that moment. If no people are detected, the unit will
automatically switch over to the energy-efficient setting.
Fan only
The air conditioner can be used as fan, blowing air without
cooling or heating.
3 area intelligent eye
Air flow is sent to a zone other than where the person is located
at that moment. Detection is done in 3 directions : left, front and
right. If no people are detected, the unit will automatically switch
over to the energy-efficient setting.
Free cooling
By exploiting the low external air temperatures to cool the water,
free cooling reduces the load on the compressors and decreases
considerably the annual operating costs during the cold season.
Energy saving during operation standby
Current consumption is reduced by about 80 % when operating
on standby. If no people are detected for more than 20 minutes,
the system will automatically switch to the current-saving mode.
Floor & presence sensor
The presence sensor directs the air away from any person
detected in the room, when the air flow control is on. The floor
sensor detects the average floor temperature and ensures an even
temperature distribution between ceiling and floor.
installation
efficiency
efficiency
General catalogue
Night set mode
Saves energy, by preventing overcooling or overheating during
night time.
Comfort
Comfort mode
The unit automatically changes the angle of the air discharge louvre
depending on the mode. In cooling operation the air will be directed
rather upwards to to avoid cold draught, while in heating operation
the air will be directed rather downwards to avoid cold feet.
Draught prevention
When starting to warm up or when the thermostat is off, the air
discharge direction is set horizontally and the fan to low speed, to
prevent draught. After warming up, air discharge and fan speed
are set as desired.
Powerful mode
If the temperature in the room is too high/low, it can be cooled
down/heated quickly by selecting the ‘powerful mode’. After the
powerful mode is turned off, the unit returns to the preset mode.
Auto cooling-heating changeover
Automatically selects cooling or heating mode to achieve
the set temperature (heat pump types only).
Whisper quiet
Daikin indoor units are whisper quiet.
Indoor unit silent operation
To ensure a quiet environment for studying or sleeping the user
can lower the operation sound of the indoor unit by 3 dB(A) via
remote control.
Outdoor unit silent operation
To ensure a quiet environment for the neighbourhood the user
can lower the operation sound of the outdoor unit by 3 dB(A) via
remote control.
Night quiet mode (cooling only)
Lowers the operation sound of the outdoor unit automatically
by 3dB(A) by removing a jumper wire on the outdoor unit.
This function can be deactivated if the jumper wire is reinstalled
on the outdoor unit.
Comfortable sleeping mode
Increased comfort function that follows a specific temperature
fluctuation rhythm.
Radiant heat
The front panel of the indoor unit radiates additional heat to add
to your comfort on cold days
operational
efficiency
design
efficiency
FAST
design
+ QUICK
+ MORE
+
installation
free heat
MAX
comfort
Our new VRV IV heat recovery systems sets pioneering
standards in all-round climate comfort efficiency.
Total design simplicity, rapid installation, full flexibility with absolute
efficiency and comfort. Find out about all revolutionary changes on
www.daikineurope.com/vrviv
Air flow
Ceiling soiling prevention
A special function prevents air blowing out too long in horizontal
position, to prevent ceiling stains.
3-D Air flow
This function combines Vertical and Horizontal auto-swing to
circulate a stream of cool/warm air right to the corners of even
large spaces.
Vertical auto swing
Possibility to select automatic vertical moving of the air discharge
louvre, for uniform air flow and temperature distribution.
Horizontal auto swing
Possibility to select automatic horizontal moving of the air
discharge louvre, for uniform air flow and temperature distribution.
Auto fan speed
Automatically selects the necessary fan speed to reach or maintain
the set temperature.
Fan speed steps
Allows to select up to the given number of fan speed.
Individual flap control
Flexible installation thanks to the possibility of easily closing
one flap via the wired remote controller, to suit any new room
configuration. Optional closure kits are available as well.
Daikin Europe N.V.
Naamloze Vennootschap Zandvoordestraat 300 · 8400 Oostende · Belgium · www.daikin.eu · BE 0412 120 336 · RPR Oostende (Responsible Editor)
Daikin Europe N.V. participates in the Eurovent Certification
programme for Air conditioners (AC), Liquid Chilling
Packages (LCP), Air handling units (AHU) and Fan coil
units (FCU), Check ongoing validity of certificate online:
www.eurovent-certification.com or using: www.certiflash.com
ECPEN15 -500_P
600 · 10/14
The present publication is drawn up by way of information only and does not constitute an offer binding upon
Daikin Europe N.V. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No
express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its
content and the products and services presented therein. Specifications are subject to change without prior notice.
Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from
or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V.
The present publication supersedes ECPEN14-500_P2. Printed on non-chlorinated paper. Prepared by Platzer
Kommunikation, Germany.
GENERAL C ATA L O G U E 2 0 1 5
3
Seasonal efficiency, smart use of energy
Seasonal efficiency gives a more realistic indication on how
efficient air conditioners operate over an entire heating or cooling
season.
Heat Recovery
2015
Benefits
Our promise...
... is to ensure that customers can depend
on Daikin for the ultimate in comfort,
so that they are free to focus
on their own working and home lives.
We promise to dedicate ourselves to technological excellence,
a design focus and the highest quality standards
so that our customers can trust and rely on the comfort we deliver.
Our promise to the planet is absolute. Our products are
at the forefront of low energy-usage and we will innovate to further
reduce the environmental impact of HVACR (Heating, Ventilation,
Air conditioning, Refrigeration) solutions.
We lead where others follow.
We will continue our global leadership in HVACR solutions
as our specialist expertise in all market sectors combined
with 90 years’ experience enable us to deliver added value
in long-lasting relationships based on trust, respect and credibility.
We promise to continue our forward-thinking ethos, treating
challenges as opportunities to produce ever-better solutions.
We will drive innovation and go the extra distance for our
customers and our company.
We will be smart and ready to do things differently.
Humidity control
Ururu - humidification
Moisture is absorbed from the outdoor air and evenly distributed
throughout the indoor areas.
Sarara - dehumidification
Reduces indoor humidity, without affecting the room
temperature, by mixing cool, dry air with warm air.
Dry programme
Allows humidity levels to be reduced without variations in room
temperature.
Air treatment
Flash streamer
The Flash Streamer generates high-speed electrons that
powerfully break down bacteria, viruses and allergens, making the
air more clean.
Titanium photocatalytic air purification filter
Removes airborne dust particles, and decomposes the odours of
for example tobacco and pets. It also decomposes harmful organic
chemical substances such as bacteria, viruses and allergens.
Photocatalytic deodorising filter
Removes airborne dust particles, decomposes odours and
restrains the reproduction of bacteria, viruses and microbes, this to
ensure a steady supply of clean air.
Air filter
Removes airborne dust particles to ensure a steady supply
of clean air.
Remote control & timer
Weekly timer
Timer can be set to start operation anytime on a daily or weekly
basis
24 Hour timer
Timer can be set to start cooling/heating anytime during
a 24-hour period.
Timer
Allows to preset the air conditioner to start/stop at a specified
time.
Infrared remote control
Infrared remote control with LCD to start, stop and regulate
the air conditioner from a distance.
Wired remote control
Wired remote control to start, stop and regulate the air
conditioner from a distance.
Centralised control
Centralised control to start, stop and regulate several
air conditioners from one central point.
Online controller
Online controller (optional): control your indoor unit from any
location via smartphone, laptop, pc, tablet or touch screen
Online controller via app
Control your indoor unit from any location via app.
(optional WLAN adapter)
We will deliver on these core values of our brand and enjoy
sustainable success with continued growth.
Other functions
Auto-restart
The unit restarts automatically at the original settings after power
failure.
Self-diagnosis
Simplifies maintenance by indicating system faults or
operating anomalies.
Twin/triple/double twin application
2, 3 or 4 indoor units can be connected to only 1 outdoor unit
even if they have different capacities. All indoor units operate
within the same mode (cooling or heating) from one remote
control.
Multi model application
Up to 5 indoor units (even different capacities) can be connected
to a single outdoor unit. All indoor units can individually be
operated within the same mode.
VRV for residential application
Up to 9 indoor units (even different capacities and up to 71 class)
can be connected to a single outdoor unit. All indoor units can
individually be operated within the same mode.
Drain pump kit
Facilitates condensation draining from the indoor unit.
Multi tenant
The indoor unit’s main power supply can be turned off when
leaving the hotel or office building.
Swing compressor
Scroll compressor
Screw compressor
Centrifugal compressor
Guaranteed operation down to -25°C
Daikin is suitable for all climates, even withstanding severe winter
conditions with an operation range down to -25°C
Guaranteed operation down to -20°C
Daikin is suitable for all climates, even withstanding severe winter
conditions with an operation range down to -20°C
Benefits
360°
We care icons
Econo mode
This function decreases the power consumption so that other
applicances that need large power consumption can be used.
This function is also energy saving.
Auto-cleaning filter
The filter automatically cleans itself once per day. Simplicity of
upkeep means optimum energy efficiency and maximum comfort
without the need for expensive or time-consuming maintenance.
Movement sensor
The sensor detects whether someone is in the room. When
the room is empty, the unit switches to economy mode after
20 minutes and restarts when a person enters the room.
Inverter technology
In combination with inverter controlled outdoor units
Home leave operation
During absence, the indoor temperature can be maintained at
a certain level.
2 area intelligent eye
Air flow is sent to a zone other than where the person is
located at that moment. If no people are detected, the unit will
automatically switch over to the energy-efficient setting.
Fan only
The air conditioner can be used as fan, blowing air without
cooling or heating.
3 area intelligent eye
Air flow is sent to a zone other than where the person is located
at that moment. Detection is done in 3 directions : left, front and
right. If no people are detected, the unit will automatically switch
over to the energy-efficient setting.
Free cooling
By exploiting the low external air temperatures to cool the water,
free cooling reduces the load on the compressors and decreases
considerably the annual operating costs during the cold season.
Energy saving during operation standby
Current consumption is reduced by about 80 % when operating
on standby. If no people are detected for more than 20 minutes,
the system will automatically switch to the current-saving mode.
Floor & presence sensor
The presence sensor directs the air away from any person
detected in the room, when the air flow control is on. The floor
sensor detects the average floor temperature and ensures an even
temperature distribution between ceiling and floor.
installation
efficiency
efficiency
General catalogue
Night set mode
Saves energy, by preventing overcooling or overheating during
night time.
Comfort
Comfort mode
The unit automatically changes the angle of the air discharge louvre
depending on the mode. In cooling operation the air will be directed
rather upwards to to avoid cold draught, while in heating operation
the air will be directed rather downwards to avoid cold feet.
Draught prevention
When starting to warm up or when the thermostat is off, the air
discharge direction is set horizontally and the fan to low speed, to
prevent draught. After warming up, air discharge and fan speed
are set as desired.
Powerful mode
If the temperature in the room is too high/low, it can be cooled
down/heated quickly by selecting the ‘powerful mode’. After the
powerful mode is turned off, the unit returns to the preset mode.
Auto cooling-heating changeover
Automatically selects cooling or heating mode to achieve
the set temperature (heat pump types only).
Whisper quiet
Daikin indoor units are whisper quiet.
Indoor unit silent operation
To ensure a quiet environment for studying or sleeping the user
can lower the operation sound of the indoor unit by 3 dB(A) via
remote control.
Outdoor unit silent operation
To ensure a quiet environment for the neighbourhood the user
can lower the operation sound of the outdoor unit by 3 dB(A) via
remote control.
Night quiet mode (cooling only)
Lowers the operation sound of the outdoor unit automatically
by 3dB(A) by removing a jumper wire on the outdoor unit.
This function can be deactivated if the jumper wire is reinstalled
on the outdoor unit.
Comfortable sleeping mode
Increased comfort function that follows a specific temperature
fluctuation rhythm.
Radiant heat
The front panel of the indoor unit radiates additional heat to add
to your comfort on cold days
operational
efficiency
design
efficiency
FAST
design
+ QUICK
+ MORE
+
installation
free heat
MAX
comfort
Our new VRV IV heat recovery systems sets pioneering
standards in all-round climate comfort efficiency.
Total design simplicity, rapid installation, full flexibility with absolute
efficiency and comfort. Find out about all revolutionary changes on
www.daikineurope.com/vrviv
Air flow
Ceiling soiling prevention
A special function prevents air blowing out too long in horizontal
position, to prevent ceiling stains.
3-D Air flow
This function combines Vertical and Horizontal auto-swing to
circulate a stream of cool/warm air right to the corners of even
large spaces.
Vertical auto swing
Possibility to select automatic vertical moving of the air discharge
louvre, for uniform air flow and temperature distribution.
Horizontal auto swing
Possibility to select automatic horizontal moving of the air
discharge louvre, for uniform air flow and temperature distribution.
Auto fan speed
Automatically selects the necessary fan speed to reach or maintain
the set temperature.
Fan speed steps
Allows to select up to the given number of fan speed.
Individual flap control
Flexible installation thanks to the possibility of easily closing
one flap via the wired remote controller, to suit any new room
configuration. Optional closure kits are available as well.
Daikin Europe N.V.
Naamloze Vennootschap Zandvoordestraat 300 · 8400 Oostende · Belgium · www.daikin.eu · BE 0412 120 336 · RPR Oostende (Responsible Editor)
Daikin Europe N.V. participates in the Eurovent Certification
programme for Air conditioners (AC), Liquid Chilling
Packages (LCP), Air handling units (AHU) and Fan coil
units (FCU), Check ongoing validity of certificate online:
www.eurovent-certification.com or using: www.certiflash.com
ECPEN15 -500_P
600 · 10/14
The present publication is drawn up by way of information only and does not constitute an offer binding upon
Daikin Europe N.V. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No
express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its
content and the products and services presented therein. Specifications are subject to change without prior notice.
Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from
or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V.
The present publication supersedes ECPEN14-500_P2. Printed on non-chlorinated paper. Prepared by Platzer
Kommunikation, Germany.
GENERAL C ATA L O G U E 2 0 1 5
3
Seasonal efficiency, smart use of energy
Seasonal efficiency gives a more realistic indication on how
efficient air conditioners operate over an entire heating or cooling
season.
Heat Recovery