G6…C(S)-250 2-way ANSI 250 Pressure Compensated Flanged Globe Valve Application This valve is typically used in Large Air Handling Units on heating or cooling coils. This valve is suitable for use in a hydronic system with variable flow. Valves are designed for ANSI 250 piping systems. Bronze or stainless steel trim valves can be used for higher pressure steam applications, depending on actuator and closeoff combination. Water Media temperature Water N40021 - 03/13 - Subject to change. © Belimo Aircontrols (USA), Inc. Steam Maximum ΔP* Water Steam Rangeability iron bronze stainless steel bronze NLP (no lip packing) 2½ 3 4 5 G665C(S)-250 G680C(S)-250 G6100C(S)-250 G6125C(S)-250 344 6 G6150C(S)-250 Suitable Actuators Spring Electronic Return Fail-Safe AVK Series 65 90 170 263 NonSpring AF 2-way Flanged 2*AF Series G6...C-250 G6...CS-250 chilled or hot water, 60% glycol, steam modified equal percentage stem up - open A to AB 2½” to 6” 250 lb. flanged Inches 2*GK Dimensions D166-2WF Service Flow characteristic Action Sizes End fitting Materials Body Seat Stem Plug Packing ANSI class Leakage Max inlet Steam Type Cv EV Series Technical Data Valve Nominal Size iron stainless steel stainless steel stainless steel NLP (no lip packing) ANSI 250 Class III 35 psi (241kPa) 100 psi (680kPa) 250 psi (1724kPa) @ 350°F 250 psi (1724kPa) @ 350°F 32°F to 300°F (0°C to 149°C) 32°F to 280°F (0°C to 138°C) 32°F to 350°F (0°C to 176°C) 32°F to 338°F (0°C to 170°C) Valve Body G665C(S)-250 G680C(S)-250 G6100C(S)-250 G6125C(S)-250 G6150C(S)-250 Valve Nominal Size Inches DN [mm] 2½” [65] 3” [80] 4” [100] 5” [125] 6” [150] Dimensions (Inches [mm]) A B 9.62” [244] 4.75” [120] 10.75” [273] 5.37” [137] 13.62” [346] 6.87” [175] 16.62” [422] 7.87” [200] 18.62” [473] 8.50” [216] 50 psi (340kPa) 25 psi (172kPa) 15 psi (103kPa) 50 psi (340kPa) G665C(S)-250 85:1 G680C(S)-250 91:1 G6100C(S)-250 98:1 G6125C(S)-250 100:1 G6150C(S)-250 98:1 Valve weights G665C(S)-250 G680C(S)-250 G6100C(S)-250 G6125C(S)-250 G6150C(S)-250 66 lbs 80 lbs 139 lbs 181 lbs 256 lbs *(50% or more open) G6...C(S)-250 2-way Flow Patterns Flow arrow shown on rear of valve Stem Up - Open A to AB 800-543-9038 USA Piping The valves should be mounted in a weather-protected area in a location that is within the ambient limits of the actuator. Allow sufficient room for valve with actuator and for service. Please allow 12” for complete actuator removal. The G6/G7 preferred mounting position of the valve is with the valve stem vertical above the valve body, for maximum life. However, the assemblies can be mounted with valve stem vertical above the valve or up to 45 degrees in relation to the horizontal pipe. The actuators should never be mounted underneath the valve, as condensation can build up and result in a failure of the actuators. Do not reverse flow direction. 866-805-7089 CANADA 203-791-8396 LATIN AMERICA 11 AVKB24-MFT Proportional, Electronic Fail-Safe, Linear, 24 V, Multi-Function Technology® Application Fail-safe for multiple control types of globe valves in HVAC steam and hydronic systems. Actuator sizing will be dictated by the valve size selection. All valve selections should be done in accordance with the flow parameters and system specifications. The actuator is mounted directly to the globe valve bonnet by means of its universal clamp and collar. The actuator operates in response to many controls types as desired by the customer and/or design control input from an electronic controller or positioner. A 2 to 10 VDC feedback signal is provided for position indication. Operation The actuator is not provided with and does not require any limit switches, but is electronically protected against overload. The AVK series provides 32 mm of downward travel and a visual indicator indicates position of the actuator. When reaching the valve end position, the actuator automatically stops. The gears can be manually disengaged with a button on the actuator cover. Input impedance Feeback Output U Stroke Linear Force Direction of rotation Position indication Manual override Running time motor Running time fail-safe Humidity Ambient temperature Storage temperature Housing Housing material Bridge Time Initial Charge Agency listings† Noise level Servicing Quality standard Weight Add-on auxiliary switches are easily fastened directly onto the actuator body for signaling and switching functions. -SR and –MFT models will have an illuminated green Adaption/Power button to reset and relearn the valve stroke as well as indicate the actuator is powered. This feature allows the actuator to rescale itself based on the actual travel. Along with the Adaption button on –MFT models will have a yellow Status light to confirm communication. Fail-Safe Indication LED status indicator lights sequence: Yellow off / Green on: operation ok, no faults Yellow off / Green blinking: fail-safe mechanism is active Yellow on / Green off: fault is detected Yellow off / Green off: not in operation / capacitors charging Yellow on / Green on: adaption running Yellow blinking / Green on: communication with programming tool Dimensions (Inches [mm]) 10.3” [262] 5.5” [140] 2.1” [53] † Use flexible metal conduit. Push the Listed conduit fitting device over the actuator’s cable to butt against the enclosure. Screw in conduit connector. Jacket the actuators input wiring with Listed flexible conduit. Properly terminate the conduit in a suitable junction box. Rated impulse Voltage 800V. Type of action 1. Control Pollution Degree 3. 800-543-9038 USA 323 866-805-7089 CANADA 203-791-8396 LATIN AMERICA / CARIBBEAN P10401 - 01/13 - Subject to change. © Belimo Aircontrols (USA), Inc. Overload protection Electrical protection Control Operating Range Y 24 VAC ± 20% 50/60 Hz, 24 VDC ± 10% 12 W 3W 21 VA (class 2 power source) 3 ft, 18 GA plenum rated cable with 1/2" conduit connector protected NEMA 2 (IP54) electronic throughout full stroke actuators are double insulated Proportional/MFT 2 to 10 VDC, 4 to 20 mA (default), variable (VDC, PWM, floating point, on/off) 100 k for 2 to 10 VDC (0.1 mA), 500 for 4 to 20 mA, 1500 for PWM, floating point and On/Off 2 to 10 VDC, 0.5 mA max, VDC variable 1.25" [32 mm] 450 lbf [2000 N] reversible with switch stroke indicator on bracket 5 mm hex crank (3/16" Allen), supplied 90 seconds (default), variable (90 to 150 seconds) 35 seconds 5 to 95% RH non condensing -22°F to +122°F [-30°C to +50°C] -40°F to +176°F [-40°C to +80°C] NEMA 2, IP54, UL enclosure type 2 Aluminum die cast and plastic casing 2 second delay before fail-safe activates 5 to 20 seconds cULus acc. to UL 60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2004/108/EC and 2006/95/EC <60dB(A) maintenance free ISO 9001 9 lbs 12.22” [310] Power supply Power consumption running Power consumption holding Transformer sizing Electrical connection The AVK… series actuators use a sensorless brushless DC motor. The ASIC inside monitors and controls the actuator’s rotation and provides a digital rotation sensing (DRS) function to prevent damage to the actuator in a stall condition. Power consumption is reduced in holding mode. 10.4” [264] Technical Data AVKB24-MFT Proportional, Electronic Fail-Safe, Linear, 24 V, Multi-Function Technology® Typical Specification 24 VAC Transformer Proportional control globe valve actuators shall be electronic and direct coupled to the globe valve bonnet via an integrated linkage, which requires no secondary linkage and be capable of mounting to valves 2.5” to 6” in size. Actuators must provide control in response to a control input from an electronic controller or positioner. Actuators shall have brushless DC motor technology and be protected from overload at all angles of rotation. Actuators shall have reversing switch and manual override on the cover. Run time shall be constant and independent of torque. Actuators shall be cULus listed, have a 5-year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by Belimo. Wiring Diagrams Blk (1) Common Line Volts Red (2) Hot Wht (3) Y Input (–) 2 to 10 VDC Feedback Signal (+) Org (5) U Output On n/Off 2 24 VAC Transformer 2 10 18 CAUTION Equipment Damage! Actuators may also be powered by 24 VDC. 7 a 500 resistor converts the 4-20 mA control signal to 2-10 VDC Blk Line Actuators may be connected in parallel if not mechanically mounted to the same shaft. Power consumption and input impedance must be observed. 3 Volts (1) – Common Red (2) + Hot A Wht (3) Y1 Input B 8 (–) 2 to 10 VDC (+) Feedback Signal 12 9 Org (5) U Output 2 to 10V Direction of rotation switch 8 Control signal may be pulsed from either the Hot (Source) or Common (Sink) 24 VAC line. 9 For triac sink the common connection from the actuator must be connected to the hot connection of the controller. Contact closures A & B also can be triacs. A & B should both be closed for the triac source and open for triac sink. 1 10 For triac sink the common connection from the actuator must be connected to the hot connection of the controller. Position feedback cannot be used with a triac sink controller. The actuator internal common reference is not compatible. A 1 12 18 3 B 18 A B 18 3 24 VAC Transformer Blk (1) Common Line Volts Red (2) + Hot 500 Ω Ω 1/4 watt (–) Control Signal (+) VDC/mA IN4004 or IN4007 diode. (IN4007 supplied, Belimo part number 40155) 18 Wht (3) Y1 Input, 2 to 10V P10401 - 01/13 - Subject to change. © Belimo Aircontrols (USA), Inc. 7 1 18 Actuators with plenum cable do not have numbers; use color codes instead. Org (5) U Output, 2 to 10V Meets cULus or UL and CSA Standard requirements without the need of an electrical ground connection. WARNING G Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. VD DC/4-20 mA 24 VAC Transformer (AC Only) Volts A B Ω (–) Control Signal (+) VDC/mA 7 Functions Min* 0% Mid* 50% Max* Normal** 18 Blk (1) Common Line C 500 Ω 1/4 watt a Red (2) + Hot Wht (3) Y1 Input, 2 to 10V Org (5) b c 100% Control mode acc. to Y * Default selectable 0-100%. See Configuration Data Sheet. ** Customizable. See Configuration Data Sheet. Override 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA / CARIBBEAN 324 Close-Off Pressures (psi) G2/G3 Non-Spring Return, Spring Return, and Electronic Fail-Safe Non-Spring Return LV 2-way G212(S) G213(S) G214(S) G215(S) G219(S) G220(S) G224(S) G225(S) G232(S) G240(S) G250(S) SV 250 250 250 250 211 211 Spring Return LF G315 G320 G325 G332 G340 G350 LVK 207 207 236 159 85 210 120 250 210 250 250 211 210 140 250 250 250 250 220 140 250 236 159 85 210 120 250 250 250 250 250 250 250 250 250 250 250 250 N40021 - 03/13 - Subject to change. © Belimo Aircontrols (USA), Inc. 250 250 250 250 SVK 250 250 250 250 211 211 220 220 140 250 236 159 85 3-way Diverting G315D G320D G325D G332D G340D G350D Electronic Fail-Safe AFB 250 250 250 250 140 140 250 250 236 159 85 3-way Mixing G314 NF 800-543-9038 USA 88 866-805-7089 CANADA 203-791-8396 LATIN AMERICA Close-Off Pressures (psi) G6/G7 Non-Spring Return, Spring Return, and Electronic Fail-Safe Non-Spring Return N40021 - 03/13 - Subject to change. © Belimo Aircontrols (USA), Inc. EV RV Spring Return AF 2-way Pressure Comp ANSI 125 G665C G680C G6100C G6125C G6150C 140 140 140 140 140 140 140 2-way Pressure Comp ANSI 125 G665CS, G665LCS G680CS, G680LCS G6100CS, G6100LCS G6125CS, G6125LCS G6150C, G6150LCS 125 125 125 125 125 125 125 2-way Pressure Comp ANSI 250 G665C-250 G680C-250 G6100C-250 G6125C-250 G6150C-250 310 310 310 310 244 310 280 2-way Pressure Comp ANSI 250 G665CS-250, G665LCS-250 G680CS-250, G680LCS-250 G6100CS-250, G6100LCS-250 G6125CS-250, G6125LCS-250 G6150CS-250, G6150LCS-250 250 250 250 250 244 250 250 3-way ANSI 125 Mixing G765, G765S G780, G780S G7100, G7100S G7125, G7125S G7150, G7150S 3-way ANSI 250 Mixing G765-250, G765S-250 G780-250, G780S-250 G7100-250, G7100S-250 G7125-250, G7125S-250 G7150-250, G7150S-250 3-way ANSI 125/250 Diverting G765D, G765DS, G765DS-250 G780D, G780DS, G780DS-250 G7100D, G7100DS, G100DS-250 G7125D, G7125DS, G7125DS-250 G7150D, G7150DS, G7150DS-250 800-543-9038 USA Electronic Fail-Safe 2*AF AVK 140 140 110 140 140 140 140 140 125 125 125 110 125 125 125 125 125 280 185 110 310 310 310 232 150 250 185 110 250 250 250 232 150 2*GK 250 94 63 33 125 125 68 42 28 40 26 100 68 12 71 47 125 125 37 94 63 33 185 125 68 42 28 40 26 100 68 12 71 47 222 152 37 22 14 140 140 140 140 175 140 140 140 140 140 140 140 175 866-805-7089 CANADA 203-791-8396 LATIN AMERICA 89
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement