Workshop Manual

Air Top 2000 ST

Type Air Top 2000 ST B (petrol)

Type Air Top 2000 ST D (diesel)

Improper installation or repair of Webasto heating and cooling systems can cause fire or the leakage of deadly carbon monoxide leading to serious injury or death.

To install and repair Webasto heating and cooling systems you need to have completed a

Webasto training course and have the appropriate technical documentation, special tools and special equipment.

Only genuine Webasto parts may be used. See also Webasto air and water heaters accessories catalogue.

NEVER try to install or repair Webasto heating or cooling systems if you have not completed a

Webasto training course, you do not have the necessary technical skills and you do not have the technical documentation, tools and equipment available to ensure that you can complete the installation and repair work properly.

ALWAYS carefully follow Webasto installation and repair instructions and heed all WARNINGS.

Webasto rejects any liability for problems and damage caused by the system being installed by untrained personnel.

Air Top 2000 ST Table of Contents

Table of Contents

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101

1.1

Contents and purpose. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101

1.1.1

Use of the air heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101

1.2

Meaning of signal words. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101

1.3

Additional documentation to be used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101

1.4

Statutory regulations and safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101

1.4.1

Statutory regulations governing installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101

1.4.2

General safety information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103

2 General description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201

2.1

Drive unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201

2.2

Heat exchanger. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202

2.3

Burner insert with combustion chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202

2.4

Control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202

2.5

Flame monitor (only petrol heater) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202

2.6

Glow plug. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203

2.7

Overheating sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203

2.8

Metering pump. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203

3 Description of operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301

3.1

Control element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301

3.2

Switching on. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301

3.3

Heating mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301

3.4

Control mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301

3.5

Control pause . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301

3.6

Switching off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302

3.7

Heater functions when installed in ADR vehicles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302

3.8

Fault lock-out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302

3.8.1

Error monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302

3.8.2

Reset a fault lock-out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303

4 Technical data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 401

5 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 501

5.1

General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 501

5.2

General error symptoms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 501

5.3

Error symptoms during function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 502

5.4

Error code output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 503

I

II

Table of Contents

6

Air Top 2000 ST

Function Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 601

6.1

General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 601

6.2

Required test and measuring equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 601

6.3

Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 602

6.3.1

Setting CO

2

content. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 602

6.3.2

CO

2

setting of reference heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 603

6.4

Testing individual components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 603

6.4.1

Burner insert component . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 604

6.4.2

Glow plug resistance test (only petrol heater) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 605

6.4.3

Glow plug component . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 607

6.4.4

Combustion air fan component (drive) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 609

6.4.5

Overheating sensor component . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 610

6.4.6

Control unit component . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 611

6.4.7

Heater component . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 612

7 Circuit diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 701

7.1

General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 701

7.2

Legend for circuit diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 705

8 Servicing work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 801

8.1

General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 801

8.2

Work on the heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 801

8.3

Work on the vehicle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 801

8.4

Heater trial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 801

8.5

Servicing work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 801

8.6

Visual inspections and installation instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 801

8.6.1

Hot air system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 801

8.6.2

Fuel supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 802

8.6.2.1

8.6.2.2

Fuel extraction.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 802

Fuel lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 804

8.6.3

Metering pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 804

8.6.3.1

Installation location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 804

8.6.3.2

Installation and attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 804

8.6.4

Fuel filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 804

8.6.5

Combustion air supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 805

8.6.6

Exhaust pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 805

8.6.7

Combustion air inlet and exhaust lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 805

8.6.8

Electrical connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 805

8.6.8.1

8.6.8.2

Heater connection, control element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 805

Supply voltage connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 806

8.6.8.3

Control element connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 806

8.7

Removal and installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 808

8.7.1

Heater, removal and installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 808

8.7.1.1

Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 808

8.7.1.2

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 808

8.8

Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 808

Air Top 2000 ST

9

Table of Contents

Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 901

9.1

General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 901

9.1.1

Work on stripped down components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 901

9.1.1.1

9.1.1.2

Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 901

Visual inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 901

9.1.2

Carrying out modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 901

9.1.2.1

Installation of an external temperature sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . 901

9.2

Dismantling and assembling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 902

9.2.1

Remove the casing parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 902

9.2.1.1

9.2.1.2

9.2.1.3

9.2.1.4

Cover for electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 902

Grille for hot air inlet and outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 902

Cover for hot air inlet and outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 902

Top shell . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 902

9.2.1.5

Bottom shell . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 902

9.2.2

Fit the casing parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 902

9.2.2.1

9.2.2.2

Bottom shell . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 902

Top shell . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 902

9.2.2.3

9.2.2.4

Cover for hot air inlet and outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 902

Grille for hot air inlet and outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 902

9.2.2.5

Cover for electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 902

9.2.3

Replace control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 904

9.2.3.1

9.2.3.2

Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 904

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 904

9.2.4

Change overheating sensor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 904

9.2.4.1

Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 904

9.2.4.2

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 904

9.2.5

Replacing combustion air fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 904

9.2.5.1

9.2.5.2

Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 904

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 904

9.2.6

Replace flame sensor (petrol heater only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 905

9.2.6.1

Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 905

9.2.6.2

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 905

9.2.7

Change glow plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 907

9.2.7.1

9.2.7.2

Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 907

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 907

9.2.8

Change burner insert, combustion pipe and heat exchanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . 909

9.2.8.1

Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 909

9.2.8.2

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 909

10 Packing, Storage and Shipping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1001

10.1 General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1001

III

Fig. 201

Fig. 202

Fig. 203

Fig. 204

Fig. 205

Fig. 206

Fig. 207

Fig. 208

Fig. 209

Fig. 210

Fig. 401

Fig. 402

Fig. 501

Fig. 502

Fig. 503

Fig. 601

Fig. 701

Fig. 702

Fig. 703

Fig. 704

Fig. 705

Fig. 706

Fig. 801

Fig. 802

Fig. 803

Fig. 804

Fig. 805

Fig. 806

Fig. 807

Fig. 808

Fig. 809

Fig. 810

Fig. 811

Fig. 812

Fig. 813

Fig. 814

Fig. 815

Fig. 901

Fig. 902

Fig. 903

Fig. 904

Fig. 905

List of Illustrations Air Top 2000 ST

List of Illustrations

Air Top 2000 ST air heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201

Air Top 2000 ST air heater without casing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201

Drive unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201

Heat exchanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202

Burner insert with combustion chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202

Control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202

Flame monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202

Glow plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203

Overheating sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203

Metering pump DP2 / DP 30.2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203

Technical data Air Top 2000 ST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 401

Setpoint values for resistance values of components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 402

General error symptoms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 501

Error symptoms during function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 502

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 503

Characteristic resistance values of a PT 2000 overheating system in a temperature range of 10 °C to 30 °C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 610

Plug assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 701

System circuit diagram Air Top 2000 ST, 12V/24V with control element and vehicle blower . . . . . . . . . . 702

System circuit diagram Air Top 2000 ST, 12V/24V with combination timer and vehicle blower . . . . . . . . 702

System circuit diagram Air Top 2000 ST, 12V/24V ADR operation with control element . . . . . . . . . . . . . 703

System circuit diagram Air Top 2000 ST, 12V/24V with combination timer and electrical battery isolation switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 703

Air Top 2000 ST with combination timer connection diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 704

Fuel supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 803

Webasto tank connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 803

Fuel extractor from the plastic tank (extraction through tank drain screw) . . . . . . . . . . . . . . . . . . . . . . . 803

Fuel extractor from the plastic tank (extraction through tank fitting). . . . . . . . . . . . . . . . . . . . . . . . . . . . 803

Pipe/hose connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 804

Metering pump DP 2 with damper, installation position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 804

Metering pump DP 30.2, installation position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 804

Fuel filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 804

Exhaust silencer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 805

Exhaust pipe ends, installation position. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 805

Remove the fastening plate on the fuse holder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 806

Fuse holder, installation position. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 806

Control element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 806

Disconnect the plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 806

Installation example for heater in recirculation mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 807

Installation of an external temperature sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 901

Remove/fit the casing parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 903

Change control unit, combustion air fan and overheating sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 906

Change the glow plug, flame sensor, burner insert and heat exchanger . . . . . . . . . . . . . . . . . . . . . . . . . 908

Starting air hole in burner insert . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 910

IV

Air Top 2000 ST Introduction

1 Introduction

1.4

Statutory regulations and safety instructions

1.1

Contents and purpose

This workshop manual is designed to assist trained personnel, with repairing both the petrol and the diesel versions of the Air Top 2000 ST air heaters.

1.1.1 Use of the air heaters

In principle, the general accident prevention regulations and current works safety instructions are applicable.

The "General safety information" that go beyond the scope of the above regulations are stated below (see 1.4.2).

Any special safety regulations relevant to this instruction manual will be highlighted in the relevant sections or text passages of the procedures.

The Webasto Air Top 2000 ST air heaters are designed

– to heat cabins, boats, trucks, minibuses, vans, ambulances and motorhomes

– to defrost vehicle windows

They are not designed for heating cargo areas used to carry hazardous substances.

The heaters operate independently of the engine and are connected directly to the fuel tank and the electrical system of the vehicle.

They may be used for vehicles with either water or aircooled engines.

1.4.1 Statutory regulations governing installation

For the Air Top 2000 ST heaters there are homologation approvals in accordance with the EC Directives 72/245/EEC

(EMC) and 2001/56/EC (heating) with the EC approval numbers: e1*72/245*2009/19*1085*__ e1*2001/56*2006/119*0022*__

Primarily the regulations of Annex VII of the Directive 2001/

56/EC and Part I and Annex 7 of the directive ECE R122 must be observed for the installation.

1.2

Meaning of signal words

Throughout this manual, the signal words WARNING,

IMPORTANT and NOTE have the following meanings:

NOTE:

The specifications of this Directive are binding in the scope of the Basic Directive EEC/70/156 and/or EC/2007/46 (for new vehicle models from 29/04/2009) and should also be observed in countries in which no special regulations exist.

WARNING

This heading is used to highlight operating instructions or procedures which, if not or not correctly followed, may result in personal injury or fatal accidents.

IMPORTANT

This heading is used to highlight operating instructions or procedures which, if not or not correctly followed, may result in damage to the equipment or its components.

Extract from the directives 2001/56/EC Annex VII and

ECE R122 Part I and Annex 7

Start of extract .

ANNEX VII

NOTE

This heading is used to direct your attention to a special feature deemed essential to highlight.

REQUIREMENTS FOR COMBUSTION HEATERS

AND THEIR INSTALLATION

1.3

Additional documentation to be used

This workshop manual contains all necessary information and instructions for the repair of Air Top 2000 ST air heaters.

Normally, there is no need to use additional documentation.

If necessary the operating / installation instructions and the installation suggestion for the specific vehicle may also be used.

1. GENERAL REQUIREMENTS

1.7.1. / 7.1. (Annex 7) A clearly visible tell-tale in the operator's field of view shall inform when the combustion heater is switched on or off.

2. / 5.3. (Part I) VEHICLE INSTALLATION REQUIRE-

MENTS

2.1. / 5.3.1. (Part I) Scope

2.1.1. / 5.3.1.1. (Part I) Subject to paragraph 2.1.2. /

5.3.1.2. (Part I) combustion heaters shall be installed according to the requirements of this Annex.

2.1.2. / 5.3.1.2. (Part I) Vehicles of category O having liquid fuel heaters are deemed to comply with the requirements of this Annex.

101

Introduction Air Top 2000 ST

2.2. / 5.3.2. (Part I) Positioning of heater

2.2.1. / 5.3.2.1. (Part I) Body sections and any other components in the vicinity of the heater must be protected from excessive heat and the possibility of fuel or oil contamination.

2.2.2. / 5.3.2.2. (Part I) The combustion heater shall not constitute a risk of fire, even in the case of overheating. This requirement shall be deemed to be fulfilled if the installation ensures an adequate distance to all parts and suitable ventilation, by the use of fire resistant materials or by the use of heat shields.

2.2.3. / 5.3.2.3. (Part I) In the case of M2 and M3 vehicles, the heater must not be positioned in the passenger compartment. However, an installation in an effectively sealed envelope which also complies with the conditions in paragraph 2.2.2. / 5.3.2.2. (Part I) may be used.

2.2.4. / 5.3.2.4. (Part I) The label referred to in paragraph 1.4 / Annex 7 paragraph 1.4. or a duplicate, must be positioned so that it can be easily read when the heater is installed in the vehicle.

2.2.5. / 5.3.2.5. (Part I) Every reasonable precaution should be taken in positioning the heater to minimise the risk of injury and damage to personal property.

2.3. / 5.3.3. (Part I) Fuel supply

2.3.1. / 5.3.3.1. (Part I) The fuel filler must not be situated in the passenger compartment and must be provided with an effective cap to prevent fuel spillage.

2.3.2. / 5.3.3.2. (Part I) In the case of liquid fuel heaters, where a supply separate to that of the vehicle is provided, the type of fuel and its filler point must be clearly labelled.

2.3.3. / 5.3.3.3. (Part I) A notice, indicating that the heater must be shut down before refuelling, must be affixed to the fuelling point. In addition a suitable instruction must be included in the manufacturer's operating manual.

2.4. / 5.3.4. (Part I) Exhaust system

2.4.1. / 5.3.4.1. (Part I) The exhaust outlet must be located so as to prevent emissions from entering the vehicle through ventilators, heated air inlets or opening windows.

2.5. / 5.3.5. (Part I) Combustion air inlet

2.5.1. / 5.3.5.1. (Part I) The air for the combustion chamber of the heater must not be drawn from the passenger compartment of the vehicle.

2.5.2. / 5.3.5.2. (Part I) The air inlet must be so positioned or guarded that blocking by rubbish or luggage is unlikely.

2.6. / 5.3.6. (Part I) Heating air inlet

2.6.1. / 5.3.6.1. (Part I) The heating air supply may be fresh or recirculated air and must be drawn from a clean area not likely to be contaminated by exhaust fumes emitted either by the propulsion engine, the combustion heater or any other vehicle source.

2.6.2. / 5.3.6.2. (Part I) The inlet duct must be protected by mesh or other suitable means.

2.7. / 5.3.7. (Part I) Heating air outlet

2.7.1. / 5.3.7.1. (Part I) Any ducting used to route the hot air through the vehicle must be so positioned or protected that no injury or damage could be caused if it were to be touched.

2.7.2. / 5.3.7.2. (Part I) The air outlet must be so positioned or guarded that blocking by rubbish or luggage is unlikely.

2.8. / 5.3.8. (Part I) Automatic control of the heating system

2.8. / 5.3.8.1. (Part I) The heating system must be switched off automatically and the supply of fuel must be stopped within five seconds when the vehicle's engine stops running. If a manual device is already activated, the heating system can stay in operation.

End of extract.

102

Air Top 2000 ST Introduction

1.4.2 General safety information

The mouth of the exhaust pipe should be installed upwards, to the side or, if the exhaust pipe passes under the floor of the vehicle, to the side or rear limit of the driver’s cab or the vehicle.

The function of important parts of the vehicle must not be adversely affected. It must not be possible for condensate or water to collect in the exhaust pipe. Drain holes may be used.

The heater must not be installed in the driver’s or passenger cabin of buses (vehicle classes M2 and M3). If the heater is nevertheless installed in such a place, the installation box must be tightly sealed against the vehicle interior. The installation box must have sufficient external ventilation to ensure that a maximum temperature of 40 °C is not exceeded in the box. Fault faults may occur if the temperature exceeds this level.

The electric cables and controls for the air-conditioning system must be arranged in the vehicle so that their proper functioning cannot be adversely affected in normal operating conditions.

The heater must be switched off at filling stations and tank farms as a result of the risk of explosion.

Wherever inflammable vapours or dust may form (for example in the vicinity of fuel, carbon, wood dust or cereal stores or the like), the heater must be switched off as a result of the risk of explosion.

Compliance with §§ 45 and 46 of the Road Vehicle Licensing Act must be ensured for the installation of fuel lines and the installation of additional fuel tanks.

The main points from this law:

The heater must not be operated in enclosed areas such as garages and workshops without an emissions extraction system, even if you use the timer, because of the risk of asphyxiation and poisoning.

– Fuel pipes must be designed in such a way that torsion in the vehicle, movements by the engine and the like do not have a negative effect on their durability. They must be protected from mechanical damage.

– Parts that carry fuel must be protected from heat that will adversely affect their function and positioned so that dripping or evaporating fuel cannot collect or ignite on hot parts or on electrical equipment.

In the event of lengthy heavy smoke development, unusual combustion noise or a smell of fuel, the heater must be put out of action by removing the fuse and must not be started again until it has been examined by Webasto-trained personnel. Claims can only be made if it can be verified that the claimant has complied with the servicing and safety instructions.

The air heater’s heat exchanger can be used for a maximum of 10 years and must then be replaced by the manufacturer or one of its authorised workshops using a genuine spare part. A label must then be affixed to the heater showing the date of sale and the wording “Genuine spare part”.

Installation regulations for Webasto fuel tanks for supplying fuel to heaters in vehicles:

When you change the heat exchanger it is essential that you also replace the overheating protection element (overheating sensor) to prevent possible function faults caused by using the old overheating sensor.

The Air Top 2000 ST air heaters are prepared for interior installation and sealing direct on the cabin floor or a cabin wall. Non-release connections must be used in the interior for combustion air and exhaust pipes with the accessories available from Webasto.

• The tank must not be installed in the passenger or driver’s cabin of buses.

• The fuel filler neck must not be inside the passenger or driver’s cabin in any vehicle.

• Fuel tanks for normal or super grades of petrol must not be immediately behind the front trim of the vehicle.

They must be separated from the engine in such a way that in the event of an accident the fuel will not be expected to ignite. This does not apply to tractor units with an open driver’s seat.

The fuel lines (Mecanyl hose) must not be immediately next to the exhaust pipe and must be thermally insulated if necessary, otherwise they will pose a fire risk.

The seal between the heater mounting and the vehicle floor must always be installed, otherwise harmful emissions may get into the interior of the vehicle.

All pipes that come into contact with fuel must have sealed connections, they must not be damaged in any way and the must be checked at regular intervals (at least the same intervals as an inspection of the vehicle as a whole). The hot and combustion air intake openings must be positioned in such a way that no water can ingress into them if the vehicle drives through a water hazard for which it has been approved.

103

Introduction Air Top 2000 ST

NOTE

If any damage or leaks are found on the fuel line, the heater must not be used until the damage has been rectified by an authorised Webasto workshop.

Put the heater out of action by removing the fuse.

Overheating

Keep the hot air inlet and hot air outlet free of dirt and foreign bodies. Dirty, blocked air lines can cause the heater to shut down due to overheating.

After an overheating lock-out, check that the air system is clear, remove any materials that may block the air current and have any damage to the air lines repaired by an authorised Webasto workshop. After this the heater lockout can be cancelled by switching it off and then on again. If this action does not produce the required success (if the heater overheats again) take it to a Webasto-authorised workshop.

Never remove the grating over the air inlet of the heater.

NOTE

Failure to follow the installation instructions and the notes contained therein will lead to all liability being refused by

Webasto.

The same applies if repairs are carried out incorrectly or with the use of parts other than genuine spare parts. This will result in the invalidation of the type approval for the heater and therefore of its homologation / EC type licence.

You must read the operating manual before starting the heater for the first time.

The air outlet jets or air vents with adjustable flaps must always be opened to some extent so that the air current through the heater is not completely blocked. At least one air vent must be non-closable.

If the heater is installed in a storage area, you must ensure that no inflammable substances are kept in this area and that other material does not restrict the air supply to the heater.

Air lines must be securely fixed to the heater (using pipe clips, for example) and all other connection points (for example vents).

IMPORTANT

The errors described below are to be avoided at all costs:

• Do not stand on the heater and do not place any heavy items on the heater or throw items at the heater.

• Do not place any items of clothing, textiles or similar materials over the heater or in front of the hot air inlet side and the hot air outlet.

• The current of hot air in the heater must not be restricted or blocked by highly inflammable substances or materials such as rags, cleaning wool, etc.

• Inflammable or explosive substances and gases must not be placed near or in contact with the heater, the hot air line, the current of hot air or the exhaust pipe.

• The heater must not be cleaned with a high pressure cleaner.

• Do not switch the heater off at the main battery switch or battery isolation switch since otherwise it is possible that it may suffer long term damage if it is switched off frequently using the battery isolation switch and this can cause damage and negative influences on the function of the heater.

104

Air Top 2000 ST General description

2 General description

The Air Top 2000 ST air heaters are based on the evaporator principle and essentially consist of the following

– The drive unit with a combustion and hot air blower

– The heat exchanger

– The burner insert with combustion chamber

– The control unit

If a fault occurs, an error code will be output in the display of the combination or standard timer. If the heater has a control element, the ON control light will flash. In addition the heater can be checked using a personal computer (see

PC heater diagnostic operating manual).

Fig. 202 Air Top 2000 ST air heater without casing

Fig. 201 Air Top 2000 ST air heater

To control and monitor it, the heater has the following components inside it:

– a control unit with temperature sensor

– a flame monitor (only petrol heater)

– a glow plug

– an overheating sensor

All Air Top 2000 ST heaters can also be controlled using an external temperature sensor.

The fuel supply is provided from an external source using a metering pump.

2.1

Drive unit

The drive unit consists of the drive motor, the combustion air blower, the heat air blower and the intake casing.

The combustion air blower supplies the air required for the combustion process from the combustion air inlet to the burner insert.

The removable hot air blower transports the hot air from the hot air inlet via the heat exchanger to the hot air outlet.

Fig. 203 Drive unit

201

General description

2.2

Heat exchanger

The heat generated by the combustion process is transferred to the air transported by the combustion and hot air blowers in the heat exchanger.

Air Top 2000 ST

2.4

Control unit

The control unit is the central component for ensuring the function is maintained and for monitoring the heater’s operation. A temperature sensor in the control unit is designed to control the room temperature. An external temperature may also be connected to all the heaters.

If a fault occurs, an error code will be output in the display of the combination timer.

If the heater has a control element, the ON control light will flash.

In addition the heater can be checked using a personal computer (see PC heater diagnostic operating manual).

Internal temperature sensor

Component plug

Fig. 204 Heat exchanger

Wiring harness

2.3

Burner insert with combustion chamber

The fuel is distributed over the burner cross-section in the combustion chamber in the burner insert. The mixture of fuel and air burns in the combustion chamber, thus causing the heat exchanger to become hot.

Fig. 206 Control unit

Combustion chamber

2.5

Flame monitor (only petrol heater)

The flame monitor is a low-ohm PTC resistor, which changes its resistance depending on the heat emitted by the flame.

This change in resistance is analysed by the control unit so that the flame status is monitored whenever the heater is operating.

Burner insert

202

Fig. 205 Burner insert with combustion chamber

Fig. 207 Flame monitor

Air Top 2000 ST General description

2.6

Glow plug 2.8

Metering pump

The mixture of fuel and air is ignited by the glow plug when the heater is started. The glow plug takes the form of an electrical resistor and is positioned in the burner insert on the side away from the flame.

The metering pump is a combined transport, metering and shut-off system for supplying fuel from the vehicle’s tank to the heater.

Fig. 210 Metering pump DP2 / DP 30.2

Fig. 208 Glow plug

2.7

Overheating sensor

The overheating sensor measures the temperatures in the rib area of the heat exchanger whenever the heater is operating. The control unit evaluates the signal and protects the heater from hot air outlet temperatures above 150 °C and surface temperatures above 80 °C by shutting down the combustion process and blowing cold air over the heater.

The heater then suffers a fault lock-out and can by restarted

by being switched off and on again (see 3.2).

Fig. 209 Overheating sensor

203

General description Air Top 2000 ST

Page for notes

204

Air Top 2000 ST Description of operation

3 Description of operation Automatic restart

3.1

Control element

If no flame is detected, the starting procedure will be repeated. The glow plug will be switched on again (cycled).

The motor for the hot and combustion air blower will be set to approx. 25% of its maximum speed.

The control element is designed to switch the heater on and off, adjust the required room temperature (intake temperature between approx. 5 °C and 35 °C) and to reset the heater after a fault.

The green LED serves as the On indicator (LED permanently lit up) and as a fault signal (LED flashes).

After approx. 30 seconds (petrol) or 50 seconds (diesel) the fuel metering pump will start, and the flame formation will begin. After a further 65 seconds (petrol) or 90 seconds

(diesel) the glow plug will be switched off and the existence of the flame established.

NOTE

ADR operation:

After an operating voltage has been applied by switching the battery isolation switch and control element to “ON”, the control unit will be set to the “Fault lock-out” position.

Before it can be restarted, the control element must be set to “OFF”.

If the heater has again failed to ignite properly, the it will be shut down using a fault slow down procedure at maximum speed after 180 seconds and will suffer a fault lock-out.

NOTE

After a restart the heater will suffer a fault lock-out. To reset the fault switch the heater off briefly (at least 2 seconds) and then on again.

3.2

Switching on

3.3

Heating mode

Set the control element to the required temperature.

If the hot air temperature is lower than the nominal temperature the heater will start

NOTE

If the temperature of the hot air intake is above the set nominal temperature, only the motor for the hot and combustion air blower will start (control pause). Special feature: The control pause speed is 0 rpm if boat heaters are used.

The function of the flame monitor is checked. If the flame monitor now reports “light”, the system will attempt to cool the flame monitor for 60 seconds. If the flame monitor still reports “light” the control unit will suffer a fault lock-out. If another monitored component has suffered a fault, the fault lock-out will take effect without any slow down time.

Whilst the heater is operating the combustion gases pass through the heat exchanger. During this process the combustion heat is given off to the walls of the heat exchanger, absorbed by the hot air transported by the hot air fan and fed into the interior of the vehicle.

The temperature of the hot air intake is measured by a temperature sensor on the intake side of the heater or an external temperature sensor. If the measured temperature is lower than the value set on the control element, the output of the heater is increased to maximum heat output.

To increase the burner service life when it is used continuously the transport capacity of the metering pump is reduced for 10 seconds every 10 minutes.

In addition, heating mode is interrupted every 8 hours in the same way as for a control pause.

Start

3.4

Control mode

When the heater is switched on the ON signal light will be lit and the glow plug will be switched on (cycled). The motor for the hot and combustion air blower will be set to approx.

50% of its maximum speed.

In the control mode the fan speed and the metering-pump pumping quantity are dependent on the heating capacity.

The glow plug is off.

3.5

Control pause

After approx. 40 seconds the fuel metering pump will start and the flame formation will begin. To improve the starting quality, the metering pump and combustion air blower are started with different frequencies and speeds.

After a further 95 seconds (petrol) or 110 seconds (diesel) the glow plug will be switched off and the existence of the flame established.

After the temperature set on the control element has been reached the heat output is reduced. The speed of the heating and combustion air blower and the delivery rate of the metering pump are reduced.

301

Description of operation Air Top 2000 ST

If, at minimum heat output, the intake temperature set on the control element is exceeded, the metering pump is shut down and the combustion process ended. To burn off the flame properly the blower speed falls after 20 seconds to low-fire rate speed and then returns to the initial speed after

15 seconds, after which it falls to the control pause speed in

3 minutes, where it remains for the entire control pause.

The control pause speed on boat heaters is 0.

If the temperature set on the control element is exceeded at the temperature sensor, the heater will restart.

NOTE

Changes to the setting on the control element are implemented by the control unit and heater after a delay.

3.6

Switching off

• No repeated or incorrect start

• Temperature sensor defective

• Overheating sensor interrupt or short circuit

• Overheating sensor installed incorrectly

• Glow plug interrupt or short circuit

• Fan motor overload or blocked or short circuit or interrupt

• Flame monitorinterrupt or short circuit

• Error in the metering pump or overheating guard circuit

(start phase only)

• Undervoltage below 10.5 V/21 V for longer than 20 seconds

• Overvoltage above 16 V/32 V for longer than 6 seconds

• Control unit defective

The fuel supply is stopped if the heater overheats. The heater continues to run in the same way as if it is switched off manually. After the slow-down phase the control module is set to fault lock-out if the overheating counter is greater than the value programmed in the data record

(currently 20).

The overheating is indicated by the indicator flashing

10 times.

When the heater is switched off the ON control LED on the control element goes out. If no fuel has been transported yet or if the heater is in the control pause, the heater is switched off immediately without a run-on period.

If the fuel transport has been started it is ended when the heater is switched off. The heater is switched off using the same method as the transition from control mode to control pause. The device is then switched off automatically.

Rectify the cause of the fault.

To reset the fault switch the heater on and off briefly (at least 2 seconds).

NOTE

The heater may be switched on again during the slow down time. In this case the slow down time is completed and the heater is then restarted.

3.8.1 Error monitoring

The overheat, incorrect start and flame failure errors are counted and cause the heater to suffer a fault lock-out after an error has occurred the maximum number of times.

3.7

Heater functions when installed in

ADR vehicles

NOTE

Only for Air Top Evo 2000 ST diesel heaters that are installed in vehicles for transporting hazardous substances (ADR).

The incorrect start counter FSZ is incremented by 1 each time the heater fails to start and decremented by 1 each time it starts correctly, but does not fall below 0. If the incorrect start counter reaches its maximum value of 7 the heater will go into the heater lock-out status HGV.

If the heater is switched off using the control element the slow down time remains unchanged.

A brief slow down time (max. 40 seconds) is started automatically if

• the vehicle’s engine is switched off

• a transport device is started.

After an ADR shut down process the control unit is in the

“Fault lock-out” position. Before it can be restarted, the control element must be set to “OFF”.

The error counter SZ is incremented by 1 each error for which there is no separate counter. The error counter is reset to 0 at the start of control mode. If the error counter reaches its maximum value of 10 the heater will go into the heater lock-out status HGV.

The overheating counter ÜHZ is incremented by 1 each time the heater overheats. If the overheating counter reaches its maximum value of 20 the heater will go into the heater lockout status HGV.

3.8

Fault lock-out

The flame failure counter FAZ is increased by 1 each time the flame fails during heating mode. The counter is decremented by 1 each time the heater is in control mode.

Errors on the various heater components and faults in the starting process and in operation are identified in the control unit. The heater is switched off and goes into fault lock-out if the following conditions occur:

302

Air Top 2000 ST

If the FAZ reaches a value of 6, the heater will go into fault lock-out mode and the permanent flame failure counter

FAZP will be incremented by 1. In control mode the permanent flame failure counter FAZP will be decremented by 1. When the heater is burning properly again, the FAZP will return to 0 after a few control cycles. If the permanent flame failure counter exceeds its maximum value of 6, however, the heater will go to permanent heater lock-out status (error code F12).

3.8.2 Reset a fault lock-out

The various fault lock-outs can be reset as follows.

Fault lock-out: Switch off heater with heater control, wait at least 2 seconds and switch back on.

Heater fault lock-out: Remove the fuse and reinsert it

Description of operation

303

Description of operation Air Top 2000 ST

Page for notes

304

Air Top 2000 ST Technical data

4 Technical data

Except where limit values are specified, the technical data listed in the table refer to the usual heater tolerances of

± 10% at an ambient temperature of + 20 °C and at the rated voltage and in rated conditions.

Electrical components:

The control unit, combustion air blower (drive), metering pump, timer*, glow plug and control element are designed for 12 V or 24 V.

The components temperature sensor and flame monitor

(only petrol heater) are not designed for a specific voltage.

* not for ADR

Fuel for Air Top 2000 ST B (petrol):

The fuel specified by the manufacturer must be used.

Fuel for Air Top 2000 ST D (diesel/PME):

The diesel fuel specified by the manufacturer in accordance with DIN EN590 must be used Class EL heating oil (not L heating oil) may also be used as long as it complies to the normal quality available on the German market pursuant to

DIN 51603.

We know of no negative influences due to additives.

If fuel is extracted from the vehicle’s tank, follow the additive instructions issued by the vehicle manufacturer.

If you change to low-temperature fuel, the heater must be operated for approx. 15 minutes so that the fuel system is filled with the new fuel.

The Air Top 2000 ST D heater is also licensed for use with

PME (bio-diesel), which complies with DIN EN 14214.

Heater

Type test permit

Model

Heat output

Operation

EMC heater

Control range

Air Top 2000 ST B Air Top 2000 ST D e1*72/245*2009/19*1085*__ e1*2001/56*2006/119*0022*__

Air heater with evaporator burner

1.0 - 2.0 kW 0.9 - 2.0 kW

Fuel consumption

Rated voltage

Operating voltage range

Rated power consumption

Max. ambient temperature:

Control range

Control range

Control Panel:

- Storage

Metering pump: - Operation

- Storage

- Operation

- Storage

Maximum combustion air inlet temperature

Adjustment range for interior temperature

Control range

Delivery rate for hot air at fan speed against 0.5 mbar

CO

2

in exhaust gas

(permitted function range)

Heater dimensions

1 kW

2 kW

Weight

EN 228

DIN 51625

0.1 - 0.2 kg/h (0.14 - 0.27 l/h)

12 V

10.5 - 16 V

14 - 29 W

EN 590

DIN 51603

DIN EN 14214

0.1 - 0.21 kg/h (0.12 - 0.24 l/h)

12/24 V

10.5 - 16 / 20.5 - 31 Volt

-40 to + 40 °C

-40 to + 85 °C

-40 to + 20 °C

-40 to + 85 °C

-40 to + 75 °C

-40 to + 85 °C

-40 to + 20 °C

+5 to + 35 °C max. 93 m

3

/h at 4750 rpm

5.0 - 8.0 %

9.0 - 12.5 %

Length 311

± 2 mm

Width 120 ± 1 mm

Height 121

± 1 mm

2.6 kg

5.0 ... 8.0 %

9.0 ... 12.5 %

Fig. 401 Technical data Air Top 2000 ST

401

Technical data

Setpoint values:

Glow plug

Drive unit

Undervoltage switch-off

(triggering time > 20 s )

Overvoltage switch-off

(triggering time > 6 s )

Air Top 2000 ST

At 25 ºC

Test current: < 5 mA

Outside

12 V red marking

0.263 - 0.323 ohms

≤ 10.5 V

24 V

Green marking

1.125 - 1.375 ohms

< 6 ohms

2- 2.5 ohms.

≤ 20.5 V

≥ 15 V ≥ 31 V

Fig. 402 Setpoint values for resistance values of components

402

Air Top 2000 ST Troubleshooting

5

5.1

Troubleshooting

General

IMPORTANT

The troubleshooting guide is restricted to the localisation of defective components. The following potential sources of malfunctions are not taken into account and should always be checked so that they can then be excluded as the cause of the particular fault:

This section describes how to identify and remedy faults on the Air Top 2000 ST air heater.

If a fault occurs, an error code will be output in the display of the combination timer. If the heater has a control element, the ON control light will flash. In addition the heater can be checked using a personal computer (see PC heater diagnostic operating manual).

• Corrosion on connectors

• Loose plug contacts

• Poor crimp contacts on plugs

• Corroded cables and fuses

• Corroded battery terminals

IMPORTANT

Troubleshooting work demands precise knowledge of the structure and theory of operation of the various components and must be carried out by trained personnel only.

If in doubt, refer to section 2 or 3 for a description of how

the functions interact.

If you wish to check individual components, the electrical plug connectors on the control unit must be disconnected.

Conduct a function test in the vehicle after rectifying each fault.

5.2

General error symptoms

NOTE

For ADR mode only

After an ADR shut-down or an operating voltage has been applied by switching the main vehicle switch and control element to “ON” the control unit will be set to the “Fault lock-out” position. Before it can be restarted the control element must be set to “OFF” or the Immediate heat button pressed on the combination timer.

The following table (Fig. 501) lists the possible error

symptoms.

Error symptom

Heater unit cuts out automatically

Heater unit emits black smoke

Possible cause Remedy

Switch heater off and then on again No combustion after start and restart

ON indicator flashes

Flame extinguishes during operation

ON indicator flashes

Heater unit overheats

ON indicator flashes

Switch heater off and then on again

Battery voltage too low

ON indicator flashes

Combustion air and/or exhaust system blocked

Fig. 501 General error symptoms

Check that the hot air system is clear, allow the heater to cool, switch heater off briefly and then on again

Charge battery

Switch heater off and then on again

Check that the combustion air and exhaust systems are clear

501

Troubleshooting Air Top 2000 ST

5.3

Error symptoms during function

The following table (Fig. 502) lists the possible error symptoms in the order in which they may occur during operation.

In the event of a fault, the error is to be located using this table and rectified. It is important that the error symptom is correctly identified.

If the error symptom is not included in this table or if the fault is not found under the specific error symptom heading, in an emergency you can contact our technicians on our service hotline.

NOTE

Every fault is indicated by the flashing LED on the control element after the slow down time has finished. If the other components are OK, a defective control unit may be the cause of all the faults.

There are states which are equivalent to faults.

Error symptom Occurrence Possible cause

No start and no illumination of the LED on the control element

No start but LED is lit immediate Incorrect cabling, defective fuse immediate The unit immediately goes into a control pause when switched on; the control pause speed is 0 rpm for a boat heater.

Fig. 502 Error symptoms during function

502

Air Top 2000 ST Troubleshooting

5.4

Error code output

If the heater is fitted with a combination timer, an error code output will appear on the display of the timer after a fault occurs.

NOTE

The error code is output if the heater is fitted with a control element after an error has occurred by the switch-on indicator/error code indicator flashing. After 5 seconds of fast flashing, the error code will be output by a sequence of long flash pulses, the number of flashes is shown in the table below (for example F04 = 4 long flash pulses).

Error code

Error (group)

F 00 Control unit error

F 01 No start

F 02 Flame failure

F 03 Undervoltage or overvoltage

F 04 Premature flame recognition

Additional information during PC diagnostic

Troubleshooting

01 Control unit error

81 EOL checksum error

11 Incorrectly coded control unit or incorrect heater (fuel type) installed (the heater will not work if this error occurs)

91 Neutrally coded or disabled control unit (the heater will not work if this error occurs)

92 Maintain command failed (the heater will not work if this error occurs)

Replace control unit

18 Customer bus defective

02 Even after the restart, no flame has formed

82 No start in test

03 The flame has gone out during operation and has not reformed after a restart attempt

83 The flame has gone out during a heating cycle more than FAZ times

(EEPROM)

Check fuel supply (tank empty, lines blocked) Clean burner insert,

Petrol:

Replace flame monitor

Diesel:

Replace overheating sensor / control unit

Check fuel supply (tank empty, lines blocked) Clean burner insert,

Petrol:

Replace flame monitor

Diesel:

Replace overheating sensor / control unit

84 The voltage was less than 10.5 V or 21

V for longer than 20 seconds

Charge battery

04 The voltage was more than 16 V or 32

V for longer than 6 seconds

05 A flame was detected before combustion had started

Diesel: Replace overheating sensor / control unit

Petrol: Replace flame monitor

Fig. 503 Troubleshooting

503

Troubleshooting Air Top 2000 ST

Error code

Error (group)

F 05

F 06

F 07

F 08

F 09

F 10

F 11

Additional information during PC diagnostic

Troubleshooting

Flame monitor interrupt or short circuit

(only petrol heater)

1A Flame monitor circuit

The switched cable of the element has a short circuit to earth

External temperature sensor interrupt or short circuit

9A Flame monitor circuit interrupt or short circuit to +Ub

14 Temperature sensor circuit short circuit to earth

Replace flame monitor

Replace flame monitor

Check cables/ replace temperature sensor

94 Temperature sensor circuit interrupt or short circuit to +Ub

Check cables and terminating resistor / replace temperature sensor

88 Break or short circuit to +Ub Check cables/ replace metering pump Metering pump interrupt or short circuit

Drive unit

(combustion and hot air blower) interrupt or short circuit

08 Short circuit to earth

89 Break or short circuit to +Ub

09 The switched drive unit cable

(combustion and hot air blower) has a short circuit to earth or the drive unit is overloaded

Check cables/ replace metering pump

Replace drive unit (combustion and hot air blower)

Eliminate the cause of the blockage / difficulty in movement

Replace drive unit (combustion and hot air blower)

Glow plug interrupt or short circuit

15 Burner motor block guard has tripped

95 Burner motor blocking detection has tripped

8A glow plug:

Break or short circuit to +Ub

Replace glow plug

Overheating

19

Glow circuit: The switched cable of the element has a short circuit to earth

06 The overheating fault lock-out has tripped (heater overheated)

17 Incorrect application or illegal insulation (OHS gradient too high)

Replace glow plug

Find and remove the cause of the overheating

NOTE

If no other cause can be found for the overheating, the pressure losses caused by the hot air distribution (too many resistance points) are too high or a hot air filter is soiled

Replace overheating sensor Overheating sensor interrupt or short circuit

AB Overheating sensor circuit: break or short circuit to +Ub

1B Overheating sensor circuit: the switched cable of the element has a short circuit to earth

Fig. 503 Troubleshooting

Replace overheating sensor

504

Air Top 2000 ST Troubleshooting

Error code

Error (group)

F 12 Heater unit lock-out

F 14

F 15

Overheating sensor incorrect position

Setpoint generator short circuit

Additional information during PC diagnostic

07 The permanent heater fault lock-out has been activated

Troubleshooting

Remove the fuse and reinsert it

NOTE

The following error has occurred several times:

Fault counter more than 3 times

Incorrect start counter more than 9 times

Overheating counter more than 3 times

Position the overheating sensor correctly 97

Incorrect position of the overheating sensor (OHS gradient too low)

9B Nominal value potentiometer circuit break or short circuit to + Ub

Fig. 503 Troubleshooting

Check cables/ replace control element

505

Troubleshooting Air Top 2000 ST

Page for notes

506

Air Top 2000 ST Function Tests

6

6.1

Function Tests

General

Webasto Diagnosis Adapter incl. software

Diagnosis Adapter ID No. 9009064_ is available from

Webasto AG.

Display of fault memory, operating data and control unit information.

This section describes the tests conducted on the heater when it is installed and not installed to verify that it is in working order.

Reference heater Air Top 2000 ST 24V Diesel

The reference heater must be subjected to continual operating checks.

WARNING

The heater must not be operated in enclosed areas such as garages and workshops without an emissions extraction system.

IMPORTANT

Complete testing of heater and control unit test for “OEM” heaters only possible in conjunction with vehicle.

6.2

Required test and measuring equipment

*1)

The following schematic diagram shows the components necessary for operating a heater.

Application-specific interfaces must be taken into account.

A calibrated metering pump, which is subjected to continual operating checks, must be used for testing. The technical requirements are contained in the Webasto product documentation. It is preferable to use Webasto components. Particular attention must be paid to work and occupational safety.

The test and measuring equipment must be calibrated and proof of measuring certificates must be available.

Digital multimeter

Testing of electrical resistance [ohms], electrical continuity

≤ 0.1 ohms

Test current < 5 mA

Voltage source, adjustable

Measuring of electrical voltage [V]

10 - 30 V

≥ 30 A

CO

2

measuring unit

Testing of CO

2 value [vol. %]

Maximum ± 0.3 vol. %

Heater test bench *1)

Heater function test

Regarding contact Webasto heater test bench:

International Technical Support - International Hotline: [email protected]

PC (personal computer)

System requirements:

– IBM-compatible PC, 486 or higher in accordance with the operating system requirements

– Main memory

≥ 8 MB in accordance with the operating system requirements

– Microsoft Windows 98, ME, NT4, 2000, XP or newer versions

– COMCTL32.DLL, Version 4.70 or higher (can be downloaded on the Internet (http://www.microsoft.com))

– 3 MB of free memory on the hard disk

– a free COM port (RS232C) or a free USB port

– Optional: Internet connection (for software updates)

– Webasto Thermo Test does not run under Windows 3.1 with Win32s

1 Setpoint generator

2 Electrical vehicle interface

3 Heater fuse

4 Hot air outlet

5 Heating-air outlet hose

6 Metering pump

7 Fuel filter

8 Fuel standpipe

9 Fuel tank

10 Fuel line

11 Exhaust pipe

12 Combustion-air intake pipe

13 Heating-air intake grill

14 Standard or combination timer

601

Function Tests Air Top 2000 ST

6.3

Settings

6.3.1 Setting CO

2

content

The CO

2

content in the emissions is set using the adjustment knob on the control element. At a constant blower speed the volume of fuel is controlled by changing the metering pump cycle.

IMPORTANT

The CO

2

measuring instruments must be calibrated.

The heater must be switched off.

1. Connect the CO

2

line to minus.

2. Turn the adjustment knob on the control element to the centre setting. The heater will start and go automatically to low-fire rate mode.

NOTE

If the heater can be adjusted the operating indicator will flash as if the control unit has suffered an error.

Diesel units:

3. Set the CO

2

value by turning the adjustment knob.

Turning it anticlockwise will reduce the CO

2

value, whilst turning it clockwise will increase it. The measured

CO

2

content at partial load (1 kW) must be between

5.0 % and 8.0 %. At full load the CO

2

content is to be

10.3 +/- 0.5 vol. % after adjustment.

Petrol units:

CO

2

content may only be adjusted with the unit at operating temperature. The unit must be operated for at least 8 minutes for this purpose. Then the CO

2 content must be set to 6.1 to -6.3 vol. % at partial load

(1 KW). At full load the CO

2

content is to be 9.9 +/- -

0.4 vol. % after adjustment.

Diesel and petrol units:

4. If the CO

2

value is in the permissible range, disconnect the CO

2

line from minus. This saves the setting.

NOTE

The heater will now run in normal mode again and can be switched off as normal using the control element.

The heater is set at the factory to match the fitted combustion air blower.

602

Air Top 2000 ST Function Tests

6.3.2 CO

2

setting of reference heater 6.4

Testing individual components

The reference heater is set to 10.3 vol.% CO

2

at a geodetic altitude of 0 metres at the factory. For later resetting, a CO

2 value must be set in accordance with the following table as per the geodetic altitude.

IMPORTANT

For function tests always disconnect the connection between the control unit and the component to be tested.

Also see paragraph 6.3.1.

NOTE

If an error occurs which cannot be detected with this procedure , the unit/component must be sent in to the

Webasto Warranty Department.

For details please contact your Webasto representative.

NOTE

Damage caused by soiling will not be recognised by

Webasto! geod. altitude [m]

CO

2

[vol. %] min. tolerance for operation [vol. %] max. tolerance for operation [vol. %]

Graph legend

1

Repair/replace component. Send component to

Webasto within the warranty period.

2

Repair/replace component if necessary and put heater into operation.

3

Repair/replace component. Only send defective component (not entire heater) to Webasto within warranty period.

603

Function Tests

6.4.1 Burner insert component

See Fig. 904, Item 5

Burner insert

Air Top 2000 ST

Procedure Testing and measuring equipment

Visual

604

Combustion chamber mechanically damaged?

yes

2

Visual inspection no

Starting air hole open?

no

1

Visual inspection yes

Pilot flame opening clear?

no

1

Visual inspection yes no blockages in the fuel pipe?

no

1

Blow through with breathing air yes

Check function on heater test bench

Can CO

2

value be adjusted with to the correct value?

no

1

2 yes

Conduct function test with reference heater.

Set reference unit to nominal CO

2 value locally after

5 minutes of fullload operation in accordance with the graphic, install the burner to be tested in the reference unit and measure the

CO

2

value after 5 minutes of fullload operation

– Heater test bench

– CO

2

measuring unit

– Webasto

Diagnosis Adapter

– PC (personal computer)

– Reference heater

Air Top 2000 ST

6.4.2 Glow plug resistance test

(only petrol heater)

See Fig. 904, Item 1

If you conduct this test with a digital multimeter, the flame monitor must have the values shown as following:

Cold testing:

Resistance at 25 °C:

Test current:

2.6 - 3.4 ohms.

< 5 mA

Hot testing:

Resistance at 800 -1000 °C:

Test current:

12 - 15 ohms.

< 5 mA

(ceramic rod at red heat over length of approx. 20 mm)

Function Tests

605

Function Tests

Flame monitor

Procedure Testing and measuring equipment

Visual

Air Top 2000 ST

Contacts detached?

yes

2

Visual inspection no yes

2

Visual inspection

Cables damaged?

no

Ceramic broken?

yes

A

Visual inspection no

Resistance outside

2.5 - 3.8 ohms?

2 no yes

1

Resistance measurement

Digital multimeter

A

Ceramic broken by effects of force?

2 yes no

1

Visual inspection

606

Air Top 2000 ST

6.4.3 Glow plug component

See Fig. 904, Item 6

NOTE

The resistance test must be carried out with an ohmmeter suitable for small resistance values.

A resistance test with a simple digital multimeter is too inaccurate to find the precise values. A new glow plug can be measured to act as a reference.

The glow plug should have the following values in the test:

24 V (green) Glow plug:

Resistance at

25 °C:

Test current:

12 V (red)

0.263 - 0.323 ohms

< 5 mA

1.125 - 1.375 ohms

< 5 mA

Function Tests

607

Function Tests

Glow plug

Procedure Testing and measuring equipment

Visual

Air Top 2000 ST

Contacts detached?

yes

2

Visual inspection no yes

2

Visual inspection

Cables damaged?

no

Ceramic broken?

yes

A

Visual inspection no

Resistance outside

1.1 - 1.6 ohms?

2 no yes

1

Resistance measurement

Digital multimeter

A

Ceramic broken by effects of force?

no

1

2 yes

Visual inspection

608

Air Top 2000 ST

6.4.4 Combustion air fan component (drive)

See Fig. 903, Item 5

Procedure

Combustion air fan (drive)

Testing and measuring equipment

Visual

Function Tests

Externally damaged?

yes

2

Visual inspection no

Installation of component in unit => short circuit to metal parts (heat exchanger etc.)?

yes

1

Continuity measurement no

Digital multimeter

Start at 10 V?

no

1

Motor start-up Voltage source yes

Bearing noises?

yes

1

Subjective test

IMPORTANT

Ensure correct polarity (+)/(–)

2 no

609

Function Tests

6.4.5 Overheating sensor component

See Fig. 903, Item 8

If you conduct this resistance test with a digital multimeter, the overheating sensor must have the values shown in the

following diagram (Fig. 601).

Overheating sensor

Air Top 2000 ST

Temperature in °C

Fig. 601 Characteristic resistance values of a PT 2000 overheating system in a temperature range of

10 °C to 30 °C

Procedure Testing and measuring equipment

Visual

610

Contacts detached?

yes

2

Visual inspection no

Cables damaged?

yes

2

Visual inspection no

Connector damaged?

yes

2

Visual inspection no

Resistance outside

2 - 2.5 kohms?

1 no yes

2

Resistance measurement

Digital multimeter

Air Top 2000 ST

6.4.6 Control unit component

See Fig. 701 and Fig. 903, Item 3

Control unit

Procedure Testing and measuring equipment

Visual

Function Tests

Externally damaged?

yes

2

Visual inspection no

Fault-free operation in reference heater?

2 yes no

1

Conduct function test with the reference unit, mount the control unit to be tested in the reference heater and conduct the function test again

– Heater test bench

– PC

(personal computer)

– Webasto

Diagnosis

Adapter

– Reference heater

611

Function Tests

6.4.7 Heater component

Air Top 2000 ST

Complete heater

Testing of all electrical components

Glow plug:

Resistance outside

1.1 - 1.6 ohms?

no

Flame monitor

(only petrol heater):

Resistance outside

2,5 - 3,8 ohms?

no

Drive unit:

Resistance outside

0 - 6 ohms?

no measuring equipment yes

3

Remove upper shell from heater and pull component connector off control unit

PCB. Wire colours of individual components:

Glow plug (yellow),

Flame monitor (brown),

Drive unit (purple),

Overheating protection

(blue)

Replace component and continue

Resistance measurement

Digital multimeter yes

3 yes

3

Replace component and continue

Resistance measurement

Replace component and continue

Resistance measurement

Digital multimeter

Digital multimeter

Installation of component in unit => short circuit to metal parts (heat exchanger etc.)?

yes

3

Replace component and continue

Continuity measurement no

All tested electrical components are OK

Digital multimeter

A

612

Air Top 2000 ST

A

Check function on heater test bench

Reading out control unit data:

Burning hours, number of starts, errors

Send printouts of diagnosis with component to

Webasto

(for contact, see beginning

of paragraph 6.4)

Fault-free operation?

yes

2

B no

Function Tests measuring equipment

Function test – Heater test bench

– PC (personal computer)

– Webasto Diagnosis

Adapter

613

Function Tests

B

Control unit test in reference heater

Air Top 2000 ST measuring equipment

Fault-free operation in reference heater? yes

Reinstalling control unit in heater to be tested no

3

Replace component and continue

Function test – Heater test bench

– CO

2 measuring unit

– PC (personal computer)

– Webasto

Diagnosis

Adapter

– Reference heater

CO

2

value within tolerance? no

Set CO

2

value in permissible range with adjusting screw yes

2

CO

2

measurement

C

614

Air Top 2000 ST Function Tests

C measuring equipment

CO

2

value adjustable? yes

2 no

Checking burner in reference heater

CO

2

value adjustable in tolerance in reference heater?

3 no yes

2

Conduct function test with reference heater.

Set reference unit to nominal CO

2

value locally after 5 minutes of full-load operation in accordance with graphic, install burner to be tested in reference unit and measure CO

2 value after 5 minutes of full-load operation

Function test

CO

2

measurement

– Heater test bench

– CO

2 measuring unit

– PC (personal computer)

– Webasto

Diagnosis

Adapter

– Reference heater

615

Function Tests Air Top 2000 ST

Page for notes

616

Air Top 2000 ST Circuit diagrams

7 Circuit diagrams

The circuit diagrams (Fig. 702 to Fig. 705) show the possible

circuits for 12 or 24 Volt with

7.1

General

The Air Top 2000 ST heater units can be operated with the heater control (setpoint generator/switch) or a combination timer.

• Control element and vehicle blower

• Combination timer and vehicle blower

• ADR operation with control element

• Combination timer and electrical battery isolation switch

Fig. 701 shows the plug assignment on the control unit.

Fig. 706 shows the schematic connection of the

combination timer.

See 7.2 for the legend of the wiring diagrams.

X6

X3

X1 = Combustion and hot air blower connection

X2 = Connection to glow plug

X3 = Overheating sensor connection

X4 = Metering pump connection

X5 = Flame monitor connection (only petrol heater)

X6 = Wiring harness connection

Fig. 701 Plug assignment

X2

X4

X5

X1

701

Circuit diagrams Air Top 2000 ST

Fig. 702 System circuit diagram Air Top 2000 ST, 12V/24V with control element and vehicle blower

702

Fig. 703 System circuit diagram Air Top 2000 ST, 12V/24V with combination timer and vehicle blower

Air Top 2000 ST Circuit diagrams

Fig. 704 System circuit diagram Air Top 2000 ST, 12V/24V ADR operation with control element

Fig. 705 System circuit diagram Air Top 2000 ST, 12V/24V with combination timer and electrical battery isolation switch

703

Circuit diagrams Air Top 2000 ST

Combination timer 1531 grey: Terminal 58 black: Terminal 15 red: Terminal 30 brown: Terminal 31

Adapter wiring harness

Fig. 706 Air Top 2000 ST with combination timer connection diagram

704

Air Top 2000 ST

7.2

Legend for circuit diagrams

Cable cross-sections

< 7.5 m

0.75 mm

1.0 mm

1.5 mm

2.5 mm

4.0 mm

2

2

2

2

2

7.5 - 15 m

1.0 mm 2

1.5 mm 2

2.5 mm 2

4.0 mm 2

6.0 mm 2 gr or rt sw bl br ge gn vi ws

Cable colours blue brown yellow green grey orange red black violet white

Circuit diagrams

Item Description

A1 Heater

A2 Control unit

B1 Flame monitor

B2 Temperature sensor

B3 Overheating sensor

B4 Temperature sensor

E Glow plug

F1 Fuse 15 A 12V/ 24

V (max. 20 A)

F2 Fuse 4 A

Comment

Air Top 2000 ST

Control unit 1574 with petrol heaters only

Internal

Overheating guard

External

Flat fuse SAE J 1284

F4 Fuse 4 A

Blade fuse SAE J 1284 not contained in wiring harness

Blade fuse SAE J 1284 not contained in wiring harness

F5 Fuse Blade fuse SAE J 1284

Value in [A] to be selected depending on line crosssection not contained in wiring harness

H1 LED, green (in item S1) Indicator

H2 LED red (in item P) Light in immediate heat button, ready indicator, switch-on indicator

H3 Heating symbol in the display (in item P)

Indicator

H4 Light (in item P and S)

H5 Light bulb/LED

Display and button lighting

Switch-on indicator pumping device

Item Description

K Relay with free-wheeling diode

Comment for vehicle fan

(only valid with OE variant)

M1 Motor

M3 Motor Vehicle

P

R1

Control element 1531

Resistor

Combustion and hot air fan

Timer and setpoint generator

With internal temperature sensor only

S1 Basic heater control On/Off switch and setpoint generator

S2

S3

S4

S5

Y1

Y2

Switch Ventilation

Switch CO

2

setting

Push button External instant heat button

Switch Auxiliary drive /Pumping device

S6

S7

Switch, single or two-pin Isolation switch

Battery isolation switch Electronically controlled isolation switch

Plug connector X8-

X13

X14 Plug connector

X15 Plug connector to item Y1 to item P

Metering pump

Solenoid valve/pump Auxiliary drive /Pumping device

705

Circuit diagrams Air Top 2000 ST

Page for notes

706

Air Top 2000 ST Servicing work

8

8.1

Servicing work

General

This section describes the servicing work that can be carried out on the heater when it is installed.

8.2

Work on the heater

Disconnect the main power cable from the vehicle’s battery before carrying out any work on the heater. The main battery power must not be disconnected whilst the heater is operating or slowing down as a result of the risk of the heater overheating and the overheating guard thus being tripped. If you wish to carry out extensive repair work on the heater, it may be a good idea to remove it completely.

Refer to the relevant installation instructions and the installation proposal for the heater for the specific vehicle for repairs that necessitate the installation position being changed.

The following servicing work is to be carried out to maintain the functional reliability of the heater:

• Check the hot air inlet and outlet for dirt and foreign bodies. (Dirty or blocked hot air lines may cause overheating.)

• Clean the exterior of the heater (avoid the ingress of water).

• Check the electrical connections for contact corrosion and to ensure that they are secure.

• Check the exhaust and combustion air lines for signs of damage and to ensure that they are clear.

• Replace the fuel filter if there is one.

• Check the fuel line and filter for leaks.

8.6

Visual inspections and installation instructions

8.6.1 Hot air system

vehicle’s system.

IMPORTANT

The integration of the heater into the vehicle’s own air system is not permitted as a result of the high pressure in the

8.3

Work on the vehicle

IMPORTANT

A temperature of 85 °C must not be exceeded in the vicinity of the heater in any circumstances (for example when competing painting work on the vehicle).

Inside the control unit there is a temperature sensor, which operates the heater in the appropriate heat output range in conjunction with the control element depending on the intake temperatures and the position of the setpoint generator. The heat output is set so that after the selected interior temperature has been reached quickly, it is then kept at this selected value. Alternatively the heaters can be operated with an external temperature sensor (see 9.1.2).

8.4

Heater trial

WARNING

The heater must not be operated in enclosed areas such as garages and workshops without an emissions extraction system, even if you use the timer.

IMPORTANT

The heater must not be operated without the cover for the control unit as this will cause it to overheat.

NOTE

Only materials that can permanently withstand temperatures of at least 130 °C may be used for the hot air line.

Maximum pressure drop between the inlet and outlet side of the hot air line 1.5 hPa (corresponds to 1.5 mbar resp.

15 mm water column).

If this value is exceeded the heat output may be reduced as a result of the hot air outlet temperature control.

8.5

Servicing work

NOTE

To prevent mechanical parts seizing, the heater should be operated for approx. 10 minutes every four weeks.

The heater requires no servicing. However, it should be checked at regular intervals, at the latest at start of the heating period (the time after which the heater will be used due to adverse weather conditions) by Webasto-trained personnel.

The internal diameter of the main section of the hot air line should be 60 mm.

When using narrower lines, the permissible pressure drop is exceeded more quickly.

The hot air hose must be secured at its connection points.

The heater can be used with grills on the air inlet and outlet side if it is used in an air circulation system. Do not short circuit the current of hot air.

801

Servicing work Air Top 2000 ST

IMPORTANT

In vehicles used to transport people, the air outlet opening is to be installed in such a way that it is at least 20 cm away from all body parts.

The heaters check the internal temperature rise automatically each time they are switched on. If this is above the specified limits, the start is cancelled and error messages

F10 is displayed. To ensure that the heater functions stably, the flow resistance of the connected hot air system must be reduced.

Vehicles with carburettor engines

The fuel may only be extracted on cars using the special

Webasto fuel extractor (for example Part No. 470 910) as close to the tank as possible. The connect may be made in either the supply or return line, in which case the return line must lead almost to the base of the tank. If this is not the case the return line may be extended.

The fuel extractor must be fitted in such a way that any air or gas bubbles are automatically discharged towards the tank.

If a filter is used for the hot air, it must have the following properties:

• The current of air must not carry any inflammable and/ or harmful fibres or particles into the heater or the interior of the vehicle.

• The filter material must be able to withstand temperatures of at least 60 °C

• The filter must be resistant to all the substances that may be drawn in with the hot air (for example moisture, salt, fuel vapours, etc.).

• The resistance of the filter must be taken into consideration when designing the hot air system

8.6.2 Fuel supply

The fuel extractor should not be located near the engine, as gas bubbles may form in the lines on account of heat radiated from the engine. This may cause problems during combustion.

Vehicles with injection engines

When installing the heater in a vehicle with fuel injection system, it is important to establish whether the vehicles fuel pump is located inside or outside the tank.

If the fuel pump is located inside the tank, fuel can only be extracted from the return line using the Webasto fuel extractor (for example Part No. 470 910), in which case it must be ensured that the return line continues almost to the bottom of the tank. If this is not the case Webasto fuel

extractor (see Fig. 802, Fig. 803 or Fig. 804) may be used.

The fuel is taken from the vehicle fuel tank or from a separate fuel tank. The values for the maximum pressure at

the fuel extraction point are shown in Figure Fig. 801.

If the fuel pump is installed outside the tank, the fuel connection may also be made between the tank and the fuel pump, again using only the Webasto fuel extractor (for example Part No. 470 910).

Permissible fuel inflow height H [m]

0.00

1.00

2.00

Maximum fuel intake height S [m]

0.00

0.50

1.00

At max. perm. pressure

[bar] in fuel line

0.20

0.11

0.03

At max. perm. negative pressure [bar] in the fuel tank

-0.10

-0.06

-0.02

8.6.2.1 Fuel extraction

Vehicles with diesel engines

The fuel must be taken from the vehicle fuel tank or from a

separate tank (see Fig. 802, Fig. 803 or Fig. 804). This

separate fuel pickup precludes any effect of pressure.

802

Air Top 2000 ST Servicing work

Plastic tank

Sealing ring l

1 l

1 l

2

+ l

2

≤ 10 m

≤ 1.2 m

≤ 8.8 m

Fig. 801 Fuel supply

Hole pattern

25

Fig. 803 Fuel extractor from the plastic tank

(extraction through tank drain screw)

Fuel standpipe

Sealing ring

Tank fitting

NOTE

Only use a tank extractor with metal fuel tanks

Fig. 802 Webasto tank connector

NOTE

The fitting must be made from metal!

Fig. 804 Fuel extractor from the plastic tank (extraction through tank fitting)

803

Servicing work Air Top 2000 ST

8.6.2.2 Fuel lines

Only steel, copper and plastic lines of plasticised, light and temperature-stabilised PA11 or PA12 (e.g. Mecanyl RWTL) pursuant to DIN 73378 may be used for the fuel lines. Since the lines normally cannot be routed with a constant rising gradient, the internal diameter must not be allowed to exceed a certain size. Air or gas bubbles will accumulate in lines with an internal diameter of more than 4 mm and these will cause malfunctions if the lines sag or are routed

downwards. The diameters specified in Fig. 801 will ensure

that bubbles do not form.

The lines should not be routed downwards from the metering pump to the heater.

Air Top 2000 ST 12 V - petrol ideally

15° - 90°

Metering pump

Installation position damper

Fig. 806 Metering pump DP 2 with damper, installation position

Air Top 2000 ST

12 V and 24 V - diesel

Unsupported fuel lines must be secured to prevent them sagging. They must be installed in such a way that they cannot be damaged by flying road chippings and high

temperatures (exhaust line).

The fuel lines must be secure at the connections using hose clips to prevent their slipping.

Connecting two pipes with a hose

The correct procedure for connecting fuel lines with hosing

is shown in Fig. 805.

Clip

Bubble

Horizontal installation

Installation position damper

Fig. 807 Metering pump DP 30.2, installation position

8.6.3.2 Installation and attachment

The metering pump must be secured with a vibrationdamping mounting. Its installation position is limited as shown in Fig. 806 in order to ensure effective autobleeding. As a result of the risk of corrosion, only genuine

Webasto parts may be used for the plug connections between the metering pump and the metering pump wiring harness.

Correct Wrong

Fig. 805 Pipe/hose connections

8.6.3 Metering pump

The metering pump is a combined delivery, metering and shutoff system and is subject to specific installation criteria

(Fig. 801, Fig. 805 and Fig. 806).

8.6.3.1 Installation location

It is advisable to install the metering pump in a cool place.

The maximum ambient temperature must not exceed

+20 °C at any time during operation.

The metering pump and fuel lines must not be installed within range of the radiated heat from hot vehicle parts.

A heat shield must be used if necessary.

8.6.4 Fuel filter

Only a Webasto filter, ident. no. 487 171, is allowed to be used if the fuel is expected to be contaminated. Install vertically if possible, however at least horizontally (check flow direction).

A

ø 5

Fig. 808 Fuel filter

0 - 90

°

804

Air Top 2000 ST Servicing work

8.6.5 Combustion air supply

Under no circumstances may the combustion air be taken from areas occupied by people. The combustion air intake opening must not point in the direction of travel. It must be located so that it cannot become clogged with dirt.

NOTE

The combustion air must be extracted using a combustion air line from a position that is as cool as possible and protected from splashing water for petrol heaters.

Both lines are to be installed falling away from the heater. If this is not possible, a condensate drain hole with a diameter of 4 mm must be made at its lowest point or a connection element with a condensate drain used.

Internal diameter of the lines:

Combustion air line:

Exhaust line:

22 mm

22 mm

If the heater is in a sealed installation box, the combustion air must be drawn in from the outside and the emissions fed to the outside. Pipe passage holes must be made in such a way as to ensure that the ingress of exhaust fumes into the interior of the vehicle should not occur.

NOTE

If the exhaust line is 2 m or more, insulated exhaust lines must be used (to prevent the temperature falling below the dew point).

Minimum bending radius: 50 mm

An attachment is required no further than 150 mm from the end of the exhaust pipe to ensure that the angle of

90° ± 10° is achieved.

If dirty combustion air is expected, a combustion air filter may be fitted (only Air Top 2000 ST D). An intake silencer must be used for an intake hose length of < 0.6 m.

8.6.6 Exhaust pipe

Rigid pipes of unalloyed or alloyed steel with a minimum wall thickness of 1.0 mm or flexible piping of alloyed steel only must be used as exhaust line. The exhaust pipe must be secured to the heater and exhaust silencer with a pipe clip,

Part No. 20965A.

The exhaust silencer (Fig. 809) should ideally be installed

near the heater. The flow direction is arbitrary.

ø 6,5

10

°

10

°

Discharge direction almost vertical

90° ± 10°

Fig. 810 Exhaust pipe ends, installation position

Fig. 809 Exhaust silencer

The heater may also be operated without a silencer.

8.6.7 Combustion air inlet and exhaust lines

To prevent damaging the metering pump cable, exhaust line must not be used to extend the combustion air supply line.

Length of the combustion air intake and exhaust lines: with silencer: max. 2.0 m without silencer: max. 5.0 m

WARNING

If the exhaust pipe ends is other than as shown in the

Fig. 810 it will pose a fire risk.

Total bends:

Combustion air line:

Exhaust line: max. 270° max. 270°

805

Servicing work Air Top 2000 ST

8.6.8 Electrical connections

8.6.8.1 Heater connection, control element

The electrical connection is to be made as shown in the

appropriate circuit diagram (see section 7).

To connect the wiring harness, remove the cover (see

9.2.1.1) on the heater and connect the wiring harness plug

to the control unit.

The wiring harness is prepared for connection to the control element (setpoint generator).

Simply pull on connector housing to unplug the connector

(Fig. 813).

Before using the heater for the first time fit the cover to prevent the illegal escape of hot air (heater overheating).

The wiring harness can be fed out of the left or right side of the heater.

8.6.8.2 Supply voltage connection

Ideally from the vehicle’s central electrical system.

An additional blade terminal fuse holder is to be fitted to protect the heater (supplied with the heater). The fuse holder may only be installed in the interior of the vehicle.

Fibre optic cable

Fig. 813 Control element

NOTE

The fibre optic cable must be in contact with the rotary knob.

NOTE

The connector housing can be locked (self-locking action) by simply pulling on the wiring harness.

Fig. 811 Remove the fastening plate on the fuse holder

F = 15A

(12V and

24V)

Fig. 812 Fuse holder, installation position

8.6.8.3 Control element connection

806

Fig. 814 Disconnect the plug

Air Top 2000 ST Servicing work

1 Control element

2 Heater

3 Metering pump and damper

4 Fuel filter (accessory)

5 Tank connector

6 Exhaust silencer

7 Fuse

Fig. 815 Installation example for heater in recirculation mode

807

Servicing work

8.7

Removal and installation

IMPORTANT

When the heater is installed it must not be dismantled.

8.7.1 Heater, removal and installation

8.7.1.1 Removal

1. Disconnect the battery.

2. Pull the cover off the top shell as described in 9.2.1.1

3. Disconnect the wiring harness plug from the control unit.

4. Disconnect the cable to the metering pump at the disconnection point.

5. If necessary disconnect the hot air hose or hoses connection.

6. Disconnect the connection for the combustion air inlet on the heater.

7. Disconnect the connections for the combustion air inlet and exhaust outlet on the heater.

8. Remove four nuts and locking washers from the heater.

9. Remove the heater and discard the seal on the exhaust outlet.

8.7.1.2 Installation

1. Place the heater with a new seal on the exhaust outlet in the installation position and secure it with 4 nuts and locking washers (use only genuine Webasto nuts).

2. Tighten the nuts to 6 +1 Nm.

3. Secure the connection for the combustion air inlet on the heater.

4. Secure the connections for the combustion air inlet and exhaust outlet on the heater.

5. Connect the metering pump cable to the metering pump wiring harness.

6. Connect the wiring harness plug to socket X7 on the control unit.

7. Fit the cover and secure it.

8. If necessary fit the hot air hose or hoses and secure them.

9. Connect the battery.

10. Bleed the fuel supply system (see 8.8).

8.8

Start-up

After you have installed the heater, bleed the fuel supply system carefully.

NOTE

As a result of the low fuel consumption the heater must be switched on several times to fill the fuel line.

Conduct a trial of the heater to check all the connections for leaks and to ensure that they are secure. If the heater suffers a fault during operation, the fault must be located and remedied.

808

Air Top 2000 ST

Air Top 2000 ST Repair

9 Repair 9.1.2.1 Installation of an external temperature sensor

9.1

General

This section describes the repair work that may be carried out on the Air Top 2000 ST heater after it has been removed from the vehicle. Any further dismantling will invalidate the warranty. Only use the spare parts from the appropriate spare parts kits for assembling the heater.

General

The heater optimally regulates the desired temperature when its temperature sensor is loaded with the air temperature of the area mainly occupied. In certain circumstances, this is not always possible using the temperature sensor integrated in the control unit due to the installation circumstances (mixing in of fresh air). In this case perfect temperature control can be ensured using an external temperature sensor fitted in the appropriate area.

9.1.1 Work on stripped down components

IMPORTANT

All sealing elements between the stripped down components and the seal on the exhaust outlet must always be discarded and replaced.

9.1.1.1 Cleaning

• Clean all stripped down components with benzene and then dry them with compressed air.

• Remove all seal residue on the components in full carefully using a suitable tool.

9.1.1.2 Visual inspection

Method

1. Select a suitable position for an external temperature sensor.

NOTE

• The temperature sensor should not be in the direct line of hot air and not close to heat sources (for example the vehicle’s own heating system).

• The sensor is to be installed at medium height in the vehicle cabin on surfaces that are as vertical as possible.

• The installation site should not be exposed to direct sunlight.

• Do not install the temperature sensor behind curtains or the like.

• Check all components for damage (cracks, deformation, wear, etc.) and fit new ones if necessary.

• Inspect the plugs and cables for corrosion, loose contacts, crimping faults, etc. and repair them if necessary.

• Check plug strips for signs of corrosion and contacts to ensure they are secure. Repair them if necessary.

9.1.2 Carrying out modifications

2. Install the external temperature sensor and route the cable to the heater controller.

3. Cut the terminating resistor off the wiring harness.

4. Crimp the connector X8 for external temperature sensor onto the end of the cable.

5. Connect the connector of the external temperature sensor to the connector X8 of the wiring harness.

6. Conduct a trial and check the control properties.

Connector X8 for external temperature sensor NOTE

The constant development of our heaters is aimed at optimising them so as to prevent failures and malfunctions.

Generally it is possible to modify heaters that are already in use. We can supply the appropriate modification kits for this purpose.

The following describes modifications that can be carried out without any great effort during standard repair work:

• Installation of an external temperature sensor for better

temperature control (see 9.1.2.1).

External temperature sensor

Terminating resistor

Fig. 901 Installation of an external temperature sensor

901

Repair Air Top 2000 ST

9.2

Dismantling and assembling

9.2.2.2 Top shell

9.2.1 Remove the casing parts

1. Place the top shell (2, Fig. 902) on the heater and secure

it in the grooves in the bottom shell.

9.2.1.1 Cover for electrical connection

9.2.2.3 Cover for hot air inlet and outlet

The cover (1,Fig. 902) can be carefully levered off using a

blunt blade in the areas marked X .

9.2.1.2 Grille for hot air inlet and outlet

NOTE

The covers for the hot air inlet and outlet are different. Fit the cover with the smaller opening at the front on the hot air fan.

The grille (5) can be released from its mounting by twisting it and then pulled off forwards.

1. Push on the covers (3 and 6, Fig. 902) until the four se-

curing holes engage properly in the detents on the bottom and top covers.

9.2.1.3 Cover for hot air inlet and outlet

Both covers (3 and 6, Fig. 902) can be released from their

mountings and removed by pressing the four detents at the top and bottom using a suitable tool.

9.2.2.4 Grille for hot air inlet and outlet

1. Fit the grilles (5, Fig. 902) on the covers for the hot air

inlet and outlet and twist them to secure them.

9.2.1.4 Top shell

9.2.2.5 Cover for electrical connection

NOTE

The covers for the hot air inlet and outlet must have been removed.

NOTE

The wiring harness is to be guided out to the left or right of the heater to suit the installation situation.

The shell (2, Fig. 902) can be lifted off by pulling it upward.

9.2.1.5 Bottom shell

1. Slide on the cover (1, Fig. 902) until it audibly engages

in the top cover.

By pulling the bottom shell (4, Fig. 902), on both sides gen-

tly around areas Y , you can release the fixing and the shell can be taken off the motor casing.

9.2.2 Fit the casing parts

9.2.2.1 Bottom shell

IMPORTANT

To ensure proper operation of the heater or the overheating sensor, the following must be observed when installing the casing:

• Four insulators are used as spacer brackets between the heat exchanger and the casing parts.

• Slide the four insulators (7, Fig. 902) onto the four

corner ribs of the heat exchanger and position them exactly next to the widened rib area.

• Make sure that all four insulators (7, Fig. 902) are

firmly seated.

IMPORTANT

When you fit the bottom shell (4,Fig. 902), spread it slightly

so that the spacers on the overheating sensor (8,Fig. 903)

are not damaged.

1. Expand the bottom shell (4, Fig. 902) slightly at the side

and fit it to the heater from underneath until the securing pins on the heater engage in the holes in the shell.

2. Fit a new seal on the exhaust outlet.

902

.

Air Top 2000 ST

1

2

Repair

3

5

5

6

1 Cover, electrical connection

2 Top shell

3 Cover, hot air outlet

4 Bottom shell

5 Grille

6 Cover, hot air inlet

7 Insulators

4

Fig. 902 Remove/fit the casing parts

Insulator positioning

7

Insulator

Widening of corner rib

903

Repair Air Top 2000 ST

9.2.3 Replace control unit

9.2.3.1 Removal

1. Remove heater (see 8.7.1.1).

2. Remove casing parts (see 9.2.1).

3. Spread apart the lock of the hot air blower.

4. Pull the hot air blower (1, Fig. 903) off the motor shaft

by hand.

5. Disconnect plug connections on control unit (3).

6. Remove screws (2) and control unit (3).

7. Complete work on stripped down components (see

9.1.1).

3. Ensure that overheating sensor is correctly positioned in heat exchanger (7).

4. Connect plug connection X5 to the control unit (3).

Ensure parallel routing of the cable duct between the ribs of the heat exchanger.

5. Slide insulators (9) onto heat exchanger.

6. Lay on casing parts (see 9.2.2).

7. Install heater (see 8.7.1.2)

9.2.5 Replacing combustion air fan

9.2.5.1 Removal

NOTE

Do not carry out any repair work to the control unit.

1. Remove the heater (see 8.7.1.1).

2. Remove the casing parts (see 9.2.1).

3. Remove the control unit (see 9.2.3.1).

9.2.3.2 Installation

1. Move control unit (3, Fig. 903) into installation position

and tighten screws (2).

2. Tighten screws to 0.7 ± 0.07 Nm..

3. Slide hot air blower (1) onto motor shaft up to stop. Lug on both sides can be heard to engage in shaft groove.

4. Produce plug-in connections on socket outlets of con-

trol unit (3) as shown in Fig. 701.

5. Lay on casing parts (see 9.2.2).

6. Install heater (see 8.7.1.2)

7. Check the CO

2

setting and adjust if necessary (see 6.3).

8. Check smooth running of the hot air blower by hand and listen for any noises when switching on later.

Sensor magnets on the hot air blower must be free of chips containing iron etc.

NOTE

A total of 9 screw heads are visible on the combustion air

fan (5, Fig. 903). Of those the outer 5 screws are used to fas-

ten the combustion air fan on the heat exchanger (7). Only these screws are to be removed.

4. Remove the screws (4).

5. Pull the combustion air fan (5) off the heat exchanger

(7), remove the seal (6) and dispose of it separately.

6. Complete the work on stripped down components (see

9.1.1).

9.2.5.2 Installation

9.2.4 Change overheating sensor

9.2.4.1 Removal

1. Remove heater (see 8.7.1.1).

2. Remove casing parts (see 9.2.1).

3. Remove insulators (9, Fig. 903).

4. Disconnect plug connection X5 on control unit (3).

Do not pull the cables.

IMPORTANT

1. Make sure that sealing surfaces on combustion air fan

(5, Fig. 903) and heat exchanger (7) are not damaged.

2. Place the new seal (6) on the flange of the combustion air fan (5).

3. Move the combustion air fan (5) into the assembly position and fasten with the screws (4) while also fastening the earth connection of the wiring harness on the engine.

4. Tighten the screws (4) to 6 ± 0.6 Nm.

5. Install the control unit (see 9.2.3.2).

6. Lay on the casing parts (see 9.2.2).

7. Install the heater (see 8.7.1.2)

8. Check the CO

2

setting and adjust if necessary

(see 6.3).

5. Lever overheating sensor (8) out of heat exchanger’s ribs (7) using a suitable tool (see Detail A).

6. Remove overheating sensor (8).

9.2.4.2 Installation

1. Conduct resistance measurement on overheating sen-

sor (8, Fig. 903) (see 6.4.5).

2. Position overheating sensor (8) on heat exchanger (7) and press it into place by hand.

IMPORTANT

No electrical connection may exist between the sensor wires and the sheet-metal bracket.

904

Air Top 2000 ST

9.2.6 Replace flame sensor (petrol heater only)

9.2.6.1 Removal

1. Remove the heater (see 8.7.1.1).

2. Remove the casing parts (see 9.2.1).

3. Remove the control unit (see 9.2.3.1).

4. Remove the combustion air fan (see 9.2.5.1).

5. Remove the two screws (2, Fig. 903) and the air baffle

(3).

6. Press the cable grommet (11) on the flame sensor connection cable out of the heat exchanger (9) to the inside.

7. Carefully bend open the securing strap (4) and pull the flame sensor (1) out of the burner insert.

8. Remove the flame sensor.

9. Complete work on stripped down components (see

9.1.1).

9.2.6.2 Installation

IMPORTANT

Route the cable of the flame sensor under the fuel line.

1. Slide the flame sensor (1, Fig. 904) through under the

fuel line, guide the connector through the hole in the heat exchanger (9) and press the cable grommet (11) into the heat exchanger (9) from the inside.

2. Guide cable with protective cable sheath through securing strap (4) and mount flame sensor (1) in burner insert

(5).

3. Press the securing strap (4) together again.

4. Fasten the air baffle (3) with the screws (2).

5. Tighten the screws (2) to 6 ± 0.6 Nm.

6. Pull the cable of the flame sensor taut.

7. Mount the combustion air fan (see 9.2.5.2).

8. Install control unit (see 9.2.3.2).

9. Lay on the casing parts (see 9.2.2).

10. Install the heater (see 8.7.1.2)

Repair

905

Repair

Detail A

1

2

3

4

5

6

7

Air Top 2000 ST

9

8

906

1 Hot air blower

2 Torx screw (3)

3 Control unit

4 Torx screw (5)

5 Combustion air fan (drive)

6 Seal

7 Heat exchanger

8 Overheating sensor

9 Insulator (4)

Fig. 903 Change control unit, combustion air fan and overheating sensor

Air Top 2000 ST Repair

9.2.7 Change glow plug

9.2.7.1 Removal

1. Remove the heater (see 8.7.1.1).

2. Remove the casing parts (see 9.2.1).

3. Remove the control unit (see 9.2.3.1).

4. Remove the combustion air fan (see 9.2.5.1).

5. Press the cable grommet (10, Fig. 904) out of

the heat exchanger (9) toward the inside.

6. Remove the four screws (2) and the air baffle (3).

5. Introduce the burner insert (5) in the heat exchanger (9).

Make sure that the cable of the flame sensor (1) (only present with petrol heater) is positioned under the fuel line.

6. Guide the plug of the glow plug and the flame sensor through the holes and press the cable grommets (10) into the heat exchanger.

IMPORTANT

In the following procedure make sure that the grommet (8) seals off tight with the heat exchanger (9).

NOTE

Check the burner insert (5) has detached from the combustion pipe (13).

7. Carefully pull out the burner insert (5) by tilting.

7. Secure the burner insert (5) and the air baffle (3) with screws (2). Tighten screws (2) to 6 ± 0.6 Nm.

8. Install the combustion air fan (see 9.2.5.2).

9. Fit the control unit (see 9.2.3.2).

10. Position the casing parts (see 9.2.2).

11. Install the heater (see 8.7.1.2)

IMPORTANT

The glow plug should be removed with extreme care and must not be twisted (risk of breakage). After lengthy operation of the burner, the glow plug may be fixed in place by fuel deposits. In this case, apply penetrating oil and allow to work until the glow plug can be removed.

8. Unscrew the screw (7), pull the glow plug (6) out of the burner insert and remove.

9. Remove the combustion pipe (13) and seal (12) from the heat exchanger (9) and dispose of the seal separately.

10. Complete work on the stripped down components (see

9.1.1).

9.2.7.2 Installation

1. Fit a new seal (12, Fig. 904) into the heat exchanger (9)

and bring the combustion pipe (13) into the assembly position.

2. Check that the starting air hole in the burner insert (5) is clear.

If necessary, clean with a wire, approx. 4 mm dia.

(see Fig. 905).

IMPORTANT

When installing the glow plug, make sure that the contacts point to the heat exchanger. Otherwise there is a risk of short-circuiting.

3. Introduce the glow plug (6) into the burner insert (5) and position the protective sheath in the slit of the burner insert.

IMPORTANT

In the following procedure make sure that the glow plug is placed in the burner insert up to the stop.

4. Secure the glow plug (6) with the screw (7). Tighten the screw (7) to 0.5 Nm.

907

Repair Air Top 2000 ST

1

2

3

4

5

6

7

8

9

908

10

11

12

13

1 Flame sensor (only petrol heater)

2 Torx screw (4)

3 Air baffle

4 Securing strap

5 Burner insert

6 Glow plug

7 Screw

8 Grommet

9 Heat exchanger

10 Cable grommet

11 Cable grommet (only petrol heater)

12 Seal

13 Combustion chamber

Fig. 904 Change the glow plug, flame sensor, burner insert and heat exchanger

Air Top 2000 ST

9.2.8 Change burner insert, combustion pipe and heat exchanger

9.2.8.1 Removal

1. Remove the heater (see 8.7.1.1).

2. Remove the casing parts (see 9.2.1).

3. Remove the control unit (see 9.2.3.1).

4. Remove the overheating sensor (see 9.2.4.1).

5. Remove the combustion air fan (see 9.2.5.1).

6. Remove the flame sensor (only petrol heater)

(see 9.2.6.1).

7. Remove the glow plug (see 9.2.7.1).

IMPORTANT

In the following procedure make sure that the fuel connection is not bent.

8. Remove the burner insert (5, Fig. 904).

9. Remove the combustion pipe (13) and seal (12) from the heat exchanger (9) and dispose of the seal (12) separately.

10. Complete work on stripped down components (see

9.1.1).

9.2.8.2 Installation

1. Fit a new seal (12, Fig. 904) into the heat exchanger (9)

and bring the combustion pipe (13) into the assembly position.

NOTE

The burner insert (5) is only fixed in place when installing the flame sensor and glow plug.

2. Fit the glow plug (see 9.2.7.2).

3. Fit the flame sensor (only petrol heater)

(see 9.2.6.2).

IMPORTANT

In the following procedure make sure that the fuel connection is not bent.

4. Introduce the burner insert (5) in the heat exchanger (9).

Make sure that the cable of the flame sensor is positioned under the fuel line.

5. Secure the burner insert (5) and the air baffle (3) with screws (2).

6. Tighten the screws (2) to 6 ± 0.6 Nm.

7. Mount the combustion air fan (see 9.2.5.2).

8. Install the control unit (see 9.2.3.2).

9. Fit the overheating sensor (see 9.2.4.2).

10. Fit the insulators (11).

11. Position the casing parts (see 9.2.2).

12. Install the heater (see 8.7.1.2)

Repair

909

Repair Air Top 2000 ST

Starting air hole

910

Fig. 905 Starting air hole in burner insert

Air Top 2000 ST

10 Packing, Storage and Shipping

10.1 General

If the heater or its components are sent to Webasto AG for testing or repair, it must be cleaned and packed in such a way that it is protected against damage during handling, transport and storage.

An ambient temperature of +85 °C or –40 °C must not be exceeded for storage.

Shipment address:

For details please contact your Webasto representative.

Packing, Storage and Shipping

1001

Packing, Storage and Shipping Air Top 2000 ST

Page for notes

1002