User manual | Eaton 9135 UPS
Add to my manuals4 Pages
Eaton 9135 is a reliable power protection solution for critical equipment and applications. It offers clean, continuous power to prevent data loss and process interruptions. With a compact 3U design, it saves valuable rack space and can be mounted in a rack or tower configuration. The hot-swappable batteries and power module increase availability, while extended battery runtime options keep essential systems powered for over an hour during outages.
advertisement
Powerware series
Eaton 9135 UPS
Product snapshot
Power rating: 5 kVA/3.5 kW; 6 kVA/4.2 kW
Voltage: 230V nominal,
200–250 Vac range
Frequency: 50/60 Hz (auto-sensing)
Configuration: Rackmount (3U) or tower
Advanced power protection for:
• Medium-density data centers
• Banking and security systems
• Manufacturing process control
• Retail point-of-sale systems
• Telecommunications/VoIP equipment.
Features
• Provides clean, continuous power to protect critical equipment and applications from power-related downtime, data loss and corruption, and process interruption
• Saves valuable rack space by delivering 5000 - 6000 VA/4200W in only 3U
• Offers deployment versatility through rack and tower installation options with rail kits and pedestals provided
• Increases availability with hot-swappable batteries and power module
• Offers extended battery runtime options to power essential systems for more than an hour during an outage
• Simplifies UPS monitoring and management with a bright LCD user interface, intuitive LanSafe® & NetWatch software
• Provides two-year limited warranty
The Eaton® 9135 UPS,
Powerware® series, resolves utility power problems and supplies continuous, conditioned power. You get clean power for valuable IT and networking equipment, battery backup to gracefully handle utility outages, and on-demand visibility into UPS status from anywhere.
Under normal power conditions, the UPS can operate in high-efficiency mode at up to
97 percent efficiency. In double conversion mode, the UPS operates at up to 91 percent efficiency.
Get more usable power for less cost
The 9135 provides exactly the level of power protection needed under the conditions of the moment—optimizing for both efficiency and performance.
The more efficient the UPS, the lower your utility and cooling bills.
Double-conversion design for superior reliability and protection
In double conversion mode, the
9135 is constantly monitoring power conditions—regulating both voltage and frequency.
Even when presented with the most severe power problems, this UPS’s output remains within two percent of nominal voltage.
Rack model and EBM installation
Hot swappable batteries
Load segments
ConnectUPS-MS Network Management Card web interface
With a wide range of acceptable input voltages, this UPS does not depend on batteries to smooth out power fluctuations. Batteries are conserved for those times when utility power is highly unstable or completely out. If an outage occurs, the 9135 transfers to battery with no break in power, making this an ideal UPS for equipment sensitive to voltage fluctuations.
More power in less space
High power density. The 9135 increases power density, delivering
5000 - 6000 VA/4200W in only 3U of rack space, freeing more rack space for IT and telecom equipments. Rail kits and tower pedestals are included with every 9135 for flexible installation.
This UPS is even more user-friendly than its predecessors offering greater distribution capabilities, with eight IEC 10A & two IEC 16A outlets to power multiple pieces of equipment without a PDU.
You can combine the 9135 with an Eaton enclosure PDU (ePDU™) to power an entire rack of equipment from a single power cord input. ePDU outlets can be monitored, switched, sequenced and managed individually, providing maximum flexibility in distributing power from the 9135.
Maximum availability for critical systems
Battery runtime for minutes or hours. During a power outage, internal batteries in the 9135 keep loads running long enough to gracefully shut down systems. Add up to four external battery modules (EBMs) to deliver more than an hour of extended runtime at full load—or hours under lighter loads. Each EBM occupies only
3U of rack space. These battery modules are hot-swappable and can be replaced at any time without interrupting UPS operation and load protection.
Maximum battery runtime for critical equipments. LanSafe power management software enables independent control of load segments. With this feature, you can manage scheduled shutdowns and sequential startups of protected loads. During a power outage, you could shut down power to less essential loads to extend battery backup time for more critical devices.
When the load segments feature is used with optional
ConnectUPS-MS connectivity cards, users can remotely re-boot locked-up network equipment. Simply access the ConnectUPS-MS card over the network, and toggle the password-protected load segment controller to get your network back online.
Service without downtime. The 9135 features hot-swappable components and an automatic internal bypass. The UPS automatically switches to an alternate power path within the unit if it senses a trouble condition with an internal component. Users can even remove and replace the battery and power modules without powering down the UPS or interrupting power to loads.
2 EATON CORPORATION Eaton 9135 UPS
Visibility, control and management from anywhere
Local UPS status at a glance. An intuitive LCD interface provides detailed information and menu-driven functions for UPS management. The entire display rotates for the best orientation, whether the UPS is used vertically as a tower unit or horizontally in a rack.
The blue, backlit LCD screen displays four lines of alphanumeric information. LEDs clearly display UPS status:
•
•
•
•
Load Protected
Downgraded Operation
Load Not Protected
UPS ON/OFF button
Choice of connectivity options. Connectivity options are available for almost any networking environment. The standard unit comes with USB and RS-232 serial communication ports and a DB-9 dry contact port. You can customize your UPS by adding MS-slot interface options for other types of communications, such as:
•
•
•
A direct connection to the Ethernet network and the Internet, with the ability to monitor and manage the UPS from a standard Web browser
Serial connection for monitoring and graceful shutdown of up to five servers running various operations systems
Serial connection for simple alarm notification via isolated contacts to signal a change of state in UPS operation (typical in
IBM® eServer® iSeries applications)
•
•
Unified management for power protection. The 9135 comes complete with the Eaton Software Suite CD, including SNMPcompatible LanSafe power management software. LanSafe provides control and visibility over multiple UPSs, using an intuitive, graphical interface. From a central vantage point anywhere within the reach of a network connection, you can:
• Establish prioritized shutdown of network devices and client/ server applications
Test all network-connected UPSs from one node
Stay informed of power problems via email broadcasts
LCD rotatable display
Web/SNMP card with ModBus
Web/SNMP card
Relay/serial interface card
MODELS
Catalog number
Rack Tower Models
PW9135G5000-XL3UEU
PW9135G6000-XL3UEU
Extended Battery Modules
PW9135N6000-EBM3U
Style number
103006721-6591
103006722-6591
103006723-6591
Rating
(VA/Watts)
5000/3500
6000/4200
NA
BATTERY BACKUP TIMES (IN MINUTES)
Loads (VA/Watts)
1000/700
2000/1400
3000/2100
Standards Internal Batteries
36
13
10
4000/2800
5000/3500
6000/4200*
7
5
4
* Runtimes available for the 6 kVA model only.
Input plug
Hardwired
Hardwired
NA
+1 EBM
132
52
40
29
22
18
Output receptacles
Hardwired + (2) C19, (8) C13
Hardwired + (2) C19, (8) C13
NA
2 EBMs
232
95
74
53
41
33
Dimensions H x W x D, mm
130 x 444 x 741
130 x 444 x 741
130 x 444 x 650
+3 EBMs
332
140
110
80
62
50
Weight, kg
57
57
77.5
+4 EBMs
433
184
146
107
83
68 www.eaton.com/powerware 3
Technical specifications
General
User interface
LEDs
Topology
Diagnostics
UPS bypass
Dimensions
Rail kit
Electrical Input
Nominal voltage
Graphical LCD with blue backlight and text in
English, French, German, Portuguese, Italian and
Spanish
Four status-indicating LEDs
Double-conversion
Full system self-test
Automatic bypass
See models selection guide
Included with all units
Voltage range
Power draw of UPS
(full load)
230V
220V-240V user selectable
156–280 Vac (output PF 0.7)
5000VA: 21.7A @230V
6000VA: 26A @230V
35A Recommended inputbreaker rating
Frequency
Frequency range
50/60 Hz autoselect
40–70 Hz
Electrical Output
Power factor
On utility voltage
0.7
±2% of nominal regulation
±2% of nominal regulation On battery voltage
Efficiency >97% in high-efficiency mode; 91% in normal mode
Frequency regulation ±3% Hz online
Load crest factor 3 to 1
Battery
Internal battery type 5.5Ah, sealed, lead-acid; maintenance free
Externa battery modules
Up to four per 9135, rail kits included for rack mounting
EBM battery type
Battery runtime
Battery recharge time
5.5 Ah, sealed, lead-acid; maintenance free
Four (4) minutes with internal batteries @100% load (0.7 PF)
For additional details, see battery runtime chart
Six (6) hours to recover 90 percent of nominal backup time after 100 percent RCD load discharge
Battery replacement Hot-swappable internal and external batteries
Start-on-battery Allows start of UPS without utility input
In the interests of continual product improvement all specifications are subject to change without notice.
Communications
Serial port
USB port
Relay output
Software
Optional communication cards
RS-232 standard, RS-232 cable provided
HID standard, for communicating with Windows XP/
Vista
DB-9 Dry Contact-common alarm standard
LanSafe & NetWatch monitoring and management software
ConnectUPS-MS Network Management Card for direct control and monitoring in SNMP-based networks
ConnectUPS-MS Card with ModBus RTU interface
Serial Management Card-MS for integration to industrial environment and building management systems, remote shutdown for IBM AS/400 systems
Environmental
Safety markings
EMC
Audible noise
Ambient operating
CE, GS
IEC/EN 62 040-2 class A
Max 46 dB
0˚C to +40˚C
Storage temperature -20˚C to +40˚C with batteries and
-25˚C to +55˚C without batteries
Relative humidity 5–90% non-condensing
Heat dissipation (BTUs/hr)
Operating mode Efficiency
Normal
Battery
91%
86%
High efficiency 97%
5 kVA
1150
1650
370
6 kVA
1350
1960
450
Eaton, Powerware, ABM, LanSafe and
PowerChain Management are trade names, trademarks, and/or service marks of Eaton
Corporation or its subsidiaries and affiliates.
All other trademarks are the property of their respective owners.
© 2008 Eaton Corporation
All Rights Reserved
Printed in Finland
1018085 rev A
October 2008
BELGIUM
Tel: +32 (0) 2 348 44 10
Tel: +32 15 44 55 00
CZECH
Tel: +420 272 760 365
DENMARK
Tel: +45 3686 7910
FINLAND
Tel: +358 9 452 661
FRANCE
Tel: +33 1 60 12 74 00 [email protected]
GERMANY
Tel: +49 7841 6040 [email protected]
ITALY
Tel: +39 02 95542 309 [email protected]
MOROCCO
Tel: +212 22 95 77 40
Fax: +212 22 95 77 41
NORWAY
Tel: +47 23 03 65 50
POLAND
Tel: +48 22 331 85 24 [email protected]
PORTUGAL
Tel: +351 21 421 74 30
Fax: +351 21 421 74 29
THE NETHERLANDS
Tel: +31 (0) 78 652 16 80 [email protected]
RUSSIA
Tel: +7 495 981 37 70
SLOVAKIA
Tel: +421 2 4463 7046
SPAIN
Tel: +34 93 475 32 03 [email protected]
SWEDEN
Tel: +46 8 598 940 00 [email protected]
UAE
Tel: +971 4 881 19 33
Fax: +971 4 881 1939
UNITED KINGDOM
Tel: +44 1753-608 700 [email protected]
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Key Features
- 5 kVA 3500 W
- 4 AC outlet(s)
- Rackmount/Tower Black