1. INTRODUCTION
This maintenance manual contains of certain information that may result in fraudulent use. Do not release any part of this manual to any end users or un-authorized persons.
The internal DIP S/W should be so set to prevent un-authorized settings or alternations.
Should a load cell has been replaced, make sure that the protection devices are properly set.
After servicing, it is necessary to go through all tests and procedures to ensure the scale meets all the meteorological and approval requirements.
Here are some features of the MPF series
1. Zero indicator
2. Tare indicator
3. Negative value indicator
4. Subtractive tare function
5. Power on zero function
6. Manual zero function
7. Auto Power Saving Function
8. Equipped with simple counting function
9. 5 1/2 x 25mm wide angle LCD digit s
10. Dual power: - By built-in rechargeable battery and external AC/DC power adaptor
11. Low battery warning signal
12. Dual color charge status indicator
13. 2 Types of Calibration
14. Overload protection devices against excessive load or shock applied
15. AC/DC power adaptor, adjustable feet and dust cover included
16. Dip Switch to prevent end-user calibration
17. Optional EL backlight and bubble level
18. Optional RS232 interface
2
2. SPECIFICATION
2.1 SYSTEM BLOCK DIAGRAM
LCD
LCD DRIVER
E+
LOAD E-
CELL S+
S-
A/D UNIT
CPU with ROM
POWER SUPPLY:
1.
AC ADAPTOR
(9V/500mA)
2.
RECHARGEABLE
BATTERY (6V 4Ah)
KEYBOARD
(4 KEYS)
Description:
When an article is placed on the platter, the load of the article is applied to the load cell inside the scale.
The resistance to the excitation current in the strain gauge will then changed and the analog output signal varies.
It is amplified and digitized continuously by the A/D converter into a digital signal. Subsequently, the resulting count is processed and managed by the CPU.
The CPU refers to the instructions from the keyboard, and then conveys the output data to LCD driver, which formats the data into readout on the display panels.
3
2.2 PHYSICAL LAYOUT OF ELECTRICAL CONNECTION
DC JACK
LOAD CELL
RECHARGEABLE
BATTERY
6V 4Ah
4 PIN
CONNECOTR
MAIN BOARD
HBW-12-X
LCD
J2
DC IN
MODE
OFF
J3
BAT
-
+
SAMPLE ON/ZERO
S- S+ E- E+
4
2.3 GENERAL SPECIFICATIONS
Overall View
5
2.3.2 Overall Dimension:
420(W) X 600(L) X 800(H) mm
2.3.3 Platter Size:
420(W) X 520(L) mm
2.3.4 Model Specifications
Model Number
Capacity
External Resolution
Tare Range
Power on Zero Range
Manual Zero Range
Operation
Environment
MPF -75
75kg
0.01kg
MPF-150
150kg
0.02kg
Full Tare
±10%F.S.
±2%F.S.
0 o
~40 o
C (32 o
~104 o
F),
Non-condensed. R.H.
≦85%
Power Consumption Normal = 0.1W
Charging = 5W
MPF-300
300kg
0.05kg
2.3.5 Main Components Used
Microprocessors: 89C51
Crystal Oscillator: 6MHz
Display Device: WTN Liquid Crystal Display
Load Cell Used: 350
Ω load cell
Load Cell Capacity: MPF-75
MPF-150
MPF-300
2.3.6 Analog Specification
Input sensitivity: 2mV/V
Zero Range Adjustment:
± 2% of rated capacity
Zero Balance Range:
±10% of rate capacity
Load Cell Excitation Voltage: DV5V
A/D Conversion Speed: 10 times/second
Internal Resolution: 30000
= 100kg
= 150kg
= 300kg
6
3. INITIAL SETUP
3.1 INTERNAL FUNCTIONS AND SETTING METHODS
INTERNAL FUNCTION TABLE
Function Symbol
1
2
F.1
F.2
3
4
F.3
F.4
Description
Span value reading and dealer calibration
Full display segment and max. capacity check
Check offset value and scale configuration
Auto power off setting
HOW TO ENTER THE REQUIRED FUNCTION MODE
a. Turn scale off.
b. Press and hold SAMPLE, then turn scale on. Scale displays F.1
c. Press SAMPLE until the required function number appears.
d. Press F e. Press F until the required setting appears.
f. Press SAMPLE to confirm.
g. Repeat step c to f for other function setting, or h. Press ON/RE-ZERO to save settings and return to normal operation.
F.1 Span Value Reading and Dealer Calibration
a. Simply enter F.1 to read the A/D counts.
b. Press ON/RE-ZERO to clear the A/D counts, apply test mass onto platter, the span value of test mass will be displayed.
c. Refer to Dealer Calibration procedures for dealer calibration.
F.2 Display Segment and Rated Capacity & Division Check
When function is entered, all segments will be displayed.
Check and make sure that no segments are missed.
F.3 Check Offset Value and Scale Configuration
a. Enter F.3, scale displays the Offset value when unloaded.
b. Apply extra load onto platter, the total internal count value will be displayed.
SELECT WEIGHT UNITS
a. Press and hold F until the weight unit appears.
b. To employ all (metric and pound) weight units, press F until lb appears. To disable pound weight unit, press F until kg appears.
c. Press ON/RE-ZERO to save setting and back to normal operation status.
7
EMPLOY SIMPLE COUNTING FUNCTION
a. Press and hold F until the weight unit appears.
b. To employ simple counting function, press F until PCS appears.
To disable simple counting function, press F until PCS disappears.
c. Press ON/RE-ZERO to save setting and back to normal operation status.
F.4 Auto Power Off Setting
Two modes are available: (Default=4_OFF)
0._OFF = Auto Power Off function is disabled.
4._OFF = Scale will automatically be turned off after 4 minutes unused.
3.2 AUTO AND DEALER CALIBRATION PROCEDURES
ACCEPTABLE LOAD FOR AUTO AND DEALER CALIBRATION
Model Number External
Division
Acceptable Auto and Dealer
Calibration Load
MPF-75
MPF-150
MPF-300
1/7500
1/7500
1/6000
* Recommended calibration load
*20kg
*50kg
*100kg
40kg
100kg
200kg
Dealer Calibration Procedures:
1. Turn scale off.
2. Press and hold SAMPLE, then turn scale on.
3. Scale displays F.1
4. Press F
5. Scale displays offset value
6. Press ON/RE-ZERO
7. Press SAMPLE
8. Press ON/RE-ZERO
9. Press SAMPLE
10.Press ON/RE-ZERO, scale displays a circle at the right hand of the display. It means the scale is ready for dealer calibration. Make sure that the figure being displayed is =0 or 1, If not, press
ON/RE-ZERO again.
11.Load calibration either load as listed on above table.
12.When value displayed is stable, press F.
13.Wait until the scale starts countdown.
14.Calibration completed and scale is ready for operation.
8
Auto Calibration Procedures:
1. Turn scale off
2. Press and hold F, then turn scale on.
3. Scale displays CAL?
4. Press F
5. Scale displays LOAD XXXX or XXXX
6. Load calibration load according to above table.
7. Wait until the scale display DONE and starts countdown.
8. Calibration completed and scale is ready for operation.
3.3 DISABLE CALIBRATION AND AVOIRDUPOIS WEIGHT UNITS WITH DIP SW. (S1)
The DIP SW.#1 is used to control calibration and avoirdupois weight units. Push this switch to ON position to disable calibration.
3.4 OFFSET AND SPAN VALUE DATA
OFFSET AND SPAN VALUE DATA TABLE
Model
Number
Offset
Value
(Thousand)
MPF-75 10~14
MPF-150 10~14
MPF-300 10-14
Span Value(Thousand) at
Various Load Applied
Offset
Control
Span
Control(Ohm)
R1A
10~15 at 20kg 20~30 at 40kg VR1 Trimmer 68K
10-15 at 50kg 20-30 at 100kg VR1 Trimmer 68K
10~15 at 100kg 20~30 at 200kg VR1 Trimmer 82K
READING OFFSET VALUE
1
2
Turn scale off
Remove all load from platter
3 Enter F.3 and read the offset value
READING SPAN VALUE
1 Turn scale off
2
3
4
5
Remove all load from platter
Enter F.1
Press ON/RE-ZERO
Apply load to platter. Span value according to load applied will be displayed.
HOW TO ADJUST OFFSET VALUE
In case the offset value is out of range, adjust the trimmer located at VR1 on the main board to obtain correct offset value.
HOW TO ADJUST SPAN VALUE
The span value is controlled by resistor located on R1A, standard resistor value of R1A is listed on the above table. If the required
9
span value is not attained, then change R1A resistor according to either case below:
Span value too low: Increase the resistance of R1A.
Span value too high: Decrease the resistance of R1A.
10
3.5 FLOW CHART
3.5.1 Auto Calibration (for end-user)
11
LCD
PANORAMA
START
PRESS "F"
& "ON/RE-ZERO"
DISPLAY
FULL SCENE
RELEASE
"ON/RE-ZERO" KEY
DISPLAY
"YES"
DISPLAY
"LOAD"
DISPLAY
"XXXX"
DISPLAY
"or"
DISPLAY
"XXXX"
CALIBRATE?
DISPLAY
"CAL.?"
RELEASE
"F" KEY
PUT A ASSIGNED
WEGHT ON PLATTER
"F"=YES
"ON/RE-ZERO"
=NO
PRESS "F" OR
"ON/RE-ZERO" KEY
CALIBRA-
TE?
YES
NO
DISPLAY
"no"
DISPLAY
"99999"
COUNT DOWN
DISPLAY
"00000"
DISPLAY
" 0 kg"
NO
NO
CORRECT WEIGHT
ASSIGNED?
YES
DISPLAY
"DONE"
DISPLAY
"99999"
COUNT DOWN
DISPLAY
"00000"
STANDBY FOR
OPERATION
WEIGHT IS STILL
ON THE PLATTER?
YES
DISPLAY
"XXXX"
"XXXX"=ASSIG-
NED WEIGHT
3.5.2 Function Test (for technicians only)
12
" F " l
START
PRESS "SAMPLE"
& "ON/RE-ZERO"
LCD PANOR-
AMIC VIEW
RELEASE
"ON/RE-ZERO" KEY
RELEASE
"SAMPLE" KEY
F1
F1
PRESS KEY?
"SAMPLE"
Other
S
F2
F2
S
99999
11111
COUNT DOWN
00000
<-
0.00 kg
STANDBY FOR
OPERATION
13
xxxx:Show offset l
DISPLAY
"XXXX".
PRESS "RE-ZERO " ?
NO k
A/D
_ counts
> 0 + / - 3
CAL.
LOOP
YES
TEST
KEYBOARD k
0
Key in
Private Code
NOTE :
1:
SAMPLE key
2: RE-ZERO key
C
PRESS KEY CODE :
1 , 2 , 1 , 2
NO
SWITCH OFF ?
LEGITIMATE
PROCEDURE
YES
0
0
NO
"
0
" Accept
Private
Code
PUT ON THE
ASSIGNED
WEIGHT
END
YES j
DISPLAY
SPAN VALUE k
: key code
DIP SW. #1
> ON?
j
NO
YES k
NO
PRESS "F" ?
YES
WEIGHT
ASSIGNED
YES
NO
C
DONE
S
14
F2
F2 s
Other
"F"
PRESS KEY?
"F"
"SAMPLE"
AXX.XX
XX.XX:Capacity
L.C.D
PANORAMIC
VIEW
PRESS KEY?
"SAMPLE" other
S
F1
F3
F3
S other
PRESS KEY?
"SAMPLE"
F4
"F"
XXXXX:
OFFSET VALUE
S
Other
PRESS KEY?
"SAMPLE"
F1
Press "F" for lasting 2 sec.
WEIGHT UNIT CHANGED: kg<--->kg/lb<--->kg/lb/pcs
15
F4
F4 other
PRESSKEY?
"SAMPLE
F1
4_oFF
" F "
Auto shut-off when not in use for 4 min.
S other
PRESSKEY?
" F "
0_oFF
"SAMPLE
"
F1
No
Auto shut-off
16
4. TROUBLE SHOOTING
4.1 TROUBLE SHOOTING LOOP
POWER ON
NO DISPLAY
COUNT DOWN?
CHECK POWER SUPPLY,
CPU,LCD,KEYBOARD
OK
COUNTS AND
THEN ZERO?
GHOST
CHECK POWER
SUPPLY,LCD,LCD
DRIVER
IC,R26~29
INCORRECT
RE-CALIBRATE
THE SCALE
DISPLAY RANDOM
FIGURE
CHECK CPU,LCD,
LCD DRIVER IC
SHOW “00000”
OK
PROPER READOUT?
OK
CORRECT READOUT?
OK
CHECK LOAD CELL,
A/D UNIT,OFFSET
VALUE
UNSTABLE
CHECK PLATTER
STOPPER,LOAD
CELL,A/D UNIT,
BAD SOLDERING
CAN’T REACH THE
FULL CAPACITY
CHECK PLATTER
STOPPER,LOAD
CELL,OFFSET
VALUE
NORMAL OPERATION
17
4.2 PARTS AND COMPONENTS TROUBLE SHOOTING
4.2.1 Power Supply Checking
4.2.1.1 Relevant parts:
Main Board (HBW-12-X)
Q3 (C1061)
ZD1 (8.2V)
BR1 (W04/1A)
Q4 (A1515)
Q1 (C945)
Q5 (C945)
R14 (1.2 ohm, 1/2W)
U6 (HT-7039)
U4(AIC 1722-50)
U5(AIC 1722-3.3)
DC JACK(SCD-021)
Description:
1) AC Adaptor: This AC Adaptor provides power for DC9~12V,500mA
2) Battery: Built-in Rechargeable Battery 6V/4Ah
18
3) How Battery is charged completely?
The charging voltage is regulated by Q3 (C1061) and ZD1 (8.2V) for about 7 volts.
The charging current will go down automatically when voltage reached.
Q1 (C945) and R14 (1.2R, 1/2W) provide Over-Current protection.
4) +3.3V power drives A/D converter device(IC 7715).
U5 (AIC 1722-3.3) is a 3.3volts Voltage Regulator.
5) +5V power drives analog and digital circuit systems.
U4 (AIC 1722-50) is a 5volts Voltage Regulator.
6) Auto-off:
If the scale is set on 4_oFF or even under LO-BAT situation, after some minutes the CPU will release a low potential signal to draw down Q2, then Q1 cuts off, the scale will be shut down immediately.
7) Low Power Detection:
The U6 (HT-7039) is designed to detect the power level. When battery voltage is less than 5.5V, it will release a low potential signal to CPU, and then CPU will instruct LCD display to show LO-BAT symbol.
4.2.1.2 Input voltage: 5.5V or higher
Check and recharge battery if voltage less than 5.5V.
Check DC-JACK or AC Adaptor if been defective.
4.2.1.3 System voltage (Vcc): 5V +/- 10%
Check that the system voltage is within 5V +/- 10% a) less than 4.5V, the CPU may not work properly.
b) more than 6V, ghost will appear on LCD.
4.2.2 Platter Stopper Checking
The platter device shall not touch anything around itself during operation. Check that the platter is not contacted with the upper
(no load) and/or lower (with load) stopper.
4.2.3 LCD Display Checking
4.2.3.1 Check that it is soldered and connected properly between LCD and driver IC (uPD7225), driver IC (uPD7225) and CPU.
4.2.3.2 Check whether LCD is broken.
4.2.4 CPU Checking
4.2.4.1 Check that all pins are seated properly into the socket.
19
4.2.4.2 Check that the Crystal Oscillator works.
4.2.4.3 Check the RESET is normally low.
4.2.5 A/D Unit Checking
4.2.5.1 Check that the +3.3V & +5V powers are correctly fed to the
A/D unit.
4.2.5.2 Check that the signal output of loadcell is adequate.
4.2.5.3 Check OP. amplifiers & A/D converter (AD7715).
When no error is found with the above checking procedures, the trouble can be caused by the load cell or the PCB itself. Replace a new one could be better to identify the defectiveness.
In this way, the readout of weight would be varied because of the output voltage of loadcell and different span value, so re-calibration is necessary after this replacement.
20
5. ELECTRICAL CIRCUITRY
5.1 SCHEMATICS
21
22
23
5.2 PCB LAYOUT
HBW-12-2 TOP LAYER
HBW-12-2 BOTTOM LAYER
24
HBW-12-2 TOP OVERLAY
HBW-12-2 BOTTOM OVERLAY
25
F0100MPF000
F0100MPF001
G0001FM0200
G0001706000
F0003MPF000
F0002MPF000
F0004MPF000
F0007MPF000
G0004FW0000
G0009706000
A1600060400
A1208020351
C1OFW000000
C1MPF010000
Z7MFW000000
A0906000210
A60********
A0905600401
A0905600400
A1204040250
G0005NBS101
6. BILL OF MATERIAL
STRUCTURE
Parts No.
E1HBW000016
A0004******
Description Specification Qty Remark
P.C.B. KIT
LOAD CELL
HBW-12-X MAINBOARD
CAPACITY = 100KG
CAPACITY = 150KG
CAPACITY = 300KG
ALUMINUM HOUSING(UPPER) MPF SERIES, 430x530mm 1
ALUMINUM HOUSING(UNDER) MPF SERIES, 430x530mm 1
INDICATOR HOUSING(UPPER) FM SERIES
INDICATOR HOUSING(UNDER) 1708S SERIES
1
1
1
1 MPF-75
1 MPF-150
1 MPF-300
S/S INDICATOR FIX PLATE MPF SERIES, T SHAPE
S/S HOUSING COVER
S/S PILLAR
PILLAR SUPPORT
ADJUSTABLE FEET
BATTERY CAP
1
MPF SERIES 430*530*1.5t 1
MPF SERIES,38
φ*65cm
MPF SERIES
FW SERIES,
φ72x50
1708S SERIES
1
1
4
1
RECHARGEABLE BATTERY
BATTERY WIRE ARRAY
GP4-6/6V 4Ah
2 PIN 35cm(SINGLE HOUSING)
1
1
PANEL PC
OVERLAY
OFW SERIES, 200*78*2t 1
MPF SERIES 1
DUST COVER
D.C. JACK
ADAPTOR
CONNECTOR
CONNECTOR
WIRE ARRAY
PLASTIC BLOCK
MFW SERIES
SCD-021
***V/9V 500mA
PLT-164-P
PLT-164-R
4 PIN 25cm
M16
1
1
1
1
1
1
1
HBW-12-X MAINBOARD
E0HBW000016
A0208072250
A0202093461
A0207017223
A0207017220
A0250070390
A0203077150
A0206000172
A0206000074
A0203076600
A0201089511
A0102000289
A0300000040
A0401007330
A0401009450
A0401015150
A0401010610
P.C.B.
I.C.
I.C.
VOLTAGE REGULATOR I.C.
VOLTAGE REGULATOR I.C.
I.C.
I.C.
I.C.
I.C.
I.C.
I.C.
L.C.D.
I.C. SOCKET
TRANSISTOR
TRANSISTOR
TRANSISTOR
TRANSISTOR
A0501004148
A0501004002
A0502000001
A0503020082
A0625050000
DIODE
DIODE
BRIDGE RECTIFIER
ZENER DIODE
L.E.D.
HBW-12-X
UPD7225G
93C46
AIC-1722-33CZT
AIC-1722-50CZL
HT7039A
AD7715-3
OP-177GS
OP07CP(AD)
7660
89C51
G289
40 PIN
A733
2SC945
A1515
C1061C OR D880
1
1 U7
1 U10
1 U5
2 U4,13
1 U6
1 U3
1 U1
1 U2
1 U12
1 U9
1 LCD1
1 U9
1 Q2
2 Q1,5
1 Q4
1 Q3
1N4148
1N4002
2 D1,3
1 D4
W04(1A) 1 BR1
1/2W 8V2(9A3) 1 ZD1
ROUND,5mm,(RED,GREEN) 1 LED1
26
A0740020050
A0801001203
A0802047309
A0803041002
A0803043002
A0803044002
A0804041003
A0804042002
A0804042322
A0805020120
A0805021101
A0805041102
A0805041103
A0805041104
A0805041153
A0805041221
A0805041334
A0805041471
A0805041472
A0805041223
A0902010020
A1005030512
A1100260000
A1301000002
A1306000003
A1500000004
A5004000003
A0701106017
A0701108016
A0701477016
A0713474063
A0720103101
A0730104050
CAPACITOR (EC) 10uF/16V (SS TYPE) 15 C12,17,19,
21,23~25,27
,31,35,38,
40~42,46
CAPACITOR (EC)
CAPACITOR (EC)
CAPACITOR (MLC)
1000uF/16V
470uF/16V
1 C14
1 C16
POLYESTER FILM CAPACITOR(MEF) 0.47uF(474) 3 C6,7,9
POLYESTER FILM CAPACITOR(PET) 0.01uF/100V(103J) 1 C1
104Z 21 C2~5,8,10,
11,13,15,
CERAMIC CAPACITOR (CC)
TRIMMER
RESISTOR NETWORK
20pF
3006P-001-203(20K)
47K OHM 9 PIN
METAL FILM RESISTOR(10PPM) 10K OHM 1/4W
18,20,22,26
,34,36,37,
39,43~45,47
2 C32,33
1 VR1
1 NR1
2 R8,10
METAL FILM RESISTOR(10PPM) 30K OHM 1/4W
METAL FILM RESISTOR(10PPM) 40K OHM 1/4W
METAL FILM RESISTOR
METAL FILM RESISTOR
METAL FILM RESISTOR
CARBON FILE RESISTOR
CARBON FILE RESISTOR
CARBON FILM RESISTOR
CARBON FILM RESISTOR
CARBON FILM RESISTOR
CARBON FILE RESISTOR
CARBON FILE RESISTOR
CARBON FILM RESISTOR
CARBON FILE RESISTOR
CARBON FILE RESISTOR
CARBON FILE RESISTOR
CONNECTOR
FERRITE BEAD
CRYSTAL
DIP S/W
TACT SW
BUZZER
HEAT SINK
100K OHM 1/4W
20K OHM 1/4W
23.2K OHM 1/4W
1.2 OHM 1/2W
100 OHM 1/2W
1K OHM 1/4W
10K OHM 1/4W
1 R7
1 R9
5 R2~6
1 R41
1 R24
1 R14
1 R11
1 R37
8 R16~18,23,
26~28,36
1 R19
2 R15,29
1 R12
100K OHM 1/4W
15K OHM 1/4W
220 OHM 1/4W
330K OHM 1/4W
470 OHM 1/4W
4.7K OHM 1/4W
22K OHM 1/4W
1 R25
1 R13
1 R30
2 R20,21
2 PIN WAFER,PITCH=3.9mm
2 J2,3
3.5 x 6 x 0.8 mm 2 L1,2
6.0 MHz
DS-02 (4 PIN)
1
1
X1
S1
KPT-1104B
OBO-15210
MB-207-20
4 SW1~4
1 BZ1
1 Q3
HBW-12-X MAINBOARD (EL OPTION)
A1400000006
A0250008030
A0501004148
A0701106017
A0730104050
A0740104100
A0805041102
A0805041105
A0805041565
A1002108000
BACK LIGHT
I.C.
DIODE
CAPACITOR (EC)
CAPACITOR (MLC)
CERAMIC CAPACITOR (CC)
CARBON FILM RESISTOR
CARBON FILM RESISTOR
CARBON FILM RESISTOR
INDUCTOR
EL-13044 (130 X 44 mm) 1 EL1
HV803
1N4148
1
1
U8
D2
10uF/16V (SS TYPE)
104Z
104Z/100V
1K OHM 1/4W
1
1
1
1
C28
C29
C30
R35
1M OHM 1/4W
5.6M OHM 1/4W
1mH
1 R33
1 R33
1 L3
27
HBW-12-X MAINBOARD (RS-232 OPTION)
A0901010040
E1EEC200000
CONNECTOR
P.C.B. KIT
4 PIN WAFER
EEC RS232 BOARD
1 CN2
1
=================================================================
28
7. APPENDIX
PARTS EXPLOSION:
29
ITEM PART NO.
PART NAME SPECIFICATION
1
F0100MPF001 ALUMINUM HOUSING(UNDER) MPF SERIES, 430x530mm
2
G0004FW0000 ADJUSTABLE FEET
FW SERIES,
φ72x50
4
A0004****** LOAD CELL NDA TYPE
QTY
1
4
1
9
F0100MPF000 ALUMINUM HOUSING(UPPER) MPF SERIES, 430x530mm
12
F0002MPF000 S/S HOUSING COVER MPF SERIES 430*530*1.5t
13
F0007MPF000 PILLAR SUPPORT
17
G0005NBS101 PLASTIC BLOCK
MPF SERIES
19
F0004MPF000 S/S PILLAR
M16
MPF SERIES,38
φ*65cm
21
A0905600401 CONNECTOR PLT-164-P
22
F0003MPF000 S/S INDICATOR FIX PLATE MPF SERIES, T SHAPE
23
G0001706000 INDICATOR HOUSING(UNDER) 1708S SERIES
24
A0906000210 D.C. JACK SCD-021
1
1
1
1
1
1
1
1
1
25
A0905600400 CONNECTOR
26
A1600060400 RECHARGEABLE BATTERY
27
A1208020351 BATTERY WIRE ARRAY
28
G0009706000 BATTERY CAP
PLT-164-R
GP4-6/6V 4Ah
2 PIN 35cm(SINGLE HOUSING) 1
31
G0001FM0200 INDICATOR HOUSING(UPPER) FM SERIES
32
E1HBW000016 P.C.B. KIT HBW-12-X MAINBOARD
34
C1OFW000000 PANEL PC
35
C1MPF010000 OVERLAY
1708S SERIES
OFW SERIES, 200*78*2t
MPF SERIES
1
1
1
1
1
1
1
30
31
32
33
34
35
36
37
38
NDA LOAD CELL SPECIFICATION SHEET
RATED CAPACITY
SAFE OVERLOAD
ULTIMATE OVERLOAD
RATED OUTPUT
5 kg f - 10 00 kgf
150%R.C.
200%R.C.
2.0mV/V
± 1%
COMBINED ERROR
ZERO RETURN(20 MIN.)
REPEATABILITY
CREEP(20 MIN.)
0.02 5%R.O.
0.02%R.O.
0.02%R.O.
0.02%R.O.
EXCITATION, RECOMMENDED
EXCITATION, MAXIMUM
10V or less
15V
ZERO BALANCE
± 1%
TERMINAL RESISTANCE, INPUT
405
Ω±3Ω
TERMINAL RESISTANCE, OUTPUT
350
±3Ω
INSULATION RESISTANCE
5000M
Ω or more (DC 50V)
TEMP. RANGE COMPENSATED
TEMP. RANGE SAFE
-10
℃~40℃
-20
℃~60℃
TEMP EFFECT ON ZERO BALANCE
0.026%R.O./10
℃
TEMP. EFFECT ON OUTPUT
0.01 5%LOAD/10
℃
39