Specification | Compaq ProLiant DA-11411 QuickSpecs

Add to my manuals
24 Pages

advertisement

Specification | Compaq ProLiant DA-11411 QuickSpecs | Manualzz

QuickSpecs

Overview

W h a t ' s N e w

Performance dual processor server blade designed with enterprise availability ProLiant BL20p Server Blade includes:

Intel  Pentium  III FC-PGA2

1.40 GHz processor (dual capability)

ServerWorks HE- SuperLite Chipset

512-MB or 1024-MB PC133-MHz

Registered ECC SDRAM memory, (2 x 1

Interleaved Memory), expandable to 4 GB

Three NC3163 Fast Ethernet Embedded

WOL (Wake On LAN) NICs standard

Two NICs are upgradable to

10/100/1000T using the Dual Gigabit

Ethernet NC7780 NIC option kit

One additional 10/100 port dedicated to

Integrated Lights-Out (iLO) Management

Smart Array 5i Controller with optional battery-backed write cache

Wide Ultra3 SCSI Drive Cage standard supports up to two 1 ″ Wide Ultra3 or

Ultra 320 hot plug hard drives

Integrated Lights-Out (iLO) Advanced

Management (ASIC on motherboard)

Plugs vertically into 6U enclosure

Up to 48 BL20p blades fit in 42U rack

ProLiant BL p-Class Server Blade

Enclosure:

• Server blades and interconnects blind mate into server blade enclosures for network connection and power

• Server blade enclosure is 6U and holds up to 8 ProLiant BL20p server blades and 2 interconnects

2 types of interconnects available:

• interconnect switches or patch panels

ProLiant BL p-Class Power Enclosure:

Use BL p-Class sizing tool to determine power based on your configuration http://activeanswers.compaq.com/aaconf igurator/PowerCalc/BL20p.xls

BL p-Class power enclosure provides shared, external, redundant power

Power enclosure is 3U and holds up to 6 hot-plug power supplies

Choose single-phase or three-phase power

BL p-Class power enclosure with power supplies not needed if using facility

-48VDC ± 10% in this case purchase DC option kit

ProLiant BL p-Class Power Distribution:

Distributes power from the power

• enclosure to the server blade enclosures

Three power distribution choices:

BL p-Class scalable bus bar •

• BL p-Class mini bus bar

• BL p-Class power bus box

BL p-Class server blade, server blade enclosure, interconnects and power enclosure protected by a limited three year warranty with optional service uplifts available

• Note: Power requirements for a ProLiant BL p-Class system: 200V − 240V AC,

30 amp or facility DC -48V ± 10%.

DA-11411 North America — Version 7 — December 4, 2002

ProLiant BL p-Class

1

QuickSpecs

Overview

C o n f i g u r a t i o n S t e p s

• For a complete configuration of the ProLiant

BL20p, do the following:

1. Select BL p-Class server blade:

Single Intel Pentium III 1.40 GHz processor, 512-MB ECC SDRAM

(2 X 256MB) (230040-B21)

( Note: Additional options include processors, memory, and Gb NIC.

)

PLUS

2. Decide how many BL p-Class Server

Blade Enclosures to purchase (each enclosure can hold up to 8 ProLiant

BL20p server blades):

BL p-Class server blade enclosure with 8

Rapid Deployment Pack licenses

(281404-B21) or

BL p-Class server blade enclosure with

Rapid Deployment Pack trial (243564-

B21)

PLUS

3. Select an Interconnect. Interconnects are sold in pairs. One pair of

Interconnects is required with each BL p-

Class server blade enclosure:

BL p-Class RJ-45 Patch panel

(with 32 RJ-45 connectors) (230766-B21) or

ProLiant BL p-Class C-GbE Interconnect

Kit (with 4 RJ-45 10/100/1000 T/TX/T and

4 RJ-45 10/100 T/TX uplink connectors)

(249655-B21) or

ProLiant BL p-Class F-GbE Interconnect

Kit (with 4 LC 1000 SX and 4 RJ-45

10/100 T/TX uplink connectors)

(279720-B21)

PLUS

4. Select BL p-Class power enclosure and power supplies based on configuration.

Use p-Class sizing tool to help determine power configuration: http://activeanswers.compaq.com/aaconfi gurator/PowerCalc/BL20p.xls

Note: Power enclosures and supplies are not needed if using facility DC

(-48V ± 10%).

Single phase power enclosure with four hot-plug power supplies

(239162-001) (Single-phase power enclosure holds a max of four power supplies; no need to order additional power supplies with this option kit) or

Three-phase power enclosure with six hotplug power supplies (230769-001) (Threephase power enclosure holds a max of six power supplies no need to order additional power supplies with this option kit)

(Power enclosures and power supplies can also be purchased separately see options list for part numbers)

PLUS

5. Select power distribution:

Scalable bus bar - Supports up to 5 server blade enclosures (240560-B21) or

Mini bus bar – Supports up to 3 server blade enclosures (240559-B21) or

Power Bus Box - connects 1 power enclosure to 1 server blade enclosure

(240562-B21)

DA-11411 North America — Version 7 — December 4, 2002

ProLiant BL p-Class

2

QuickSpecs

Standard Features

(Server Blade)

ProLiant BL p-Class

ProLiant BL20p Server Blade

Processor Intel Pentium III FC-PGA2 processor 1.40 GHz

Upgradability

Cache Memory

Chipset

Upgradable to dual processing

512-KB Level 2 Cache

ServerWorks HE- SuperLite Chipset

Note: For more information regarding ServerWorks, please see the following URL: http://www.serverworks.com/products/overview.html

.

Memory

Network Controller

Manageability

Internal Storage

Expansion Slots

Product Demo

Standard

Four NICs total:

Three Compaq NC3163 Fast Ethernet NIC PCI 10/100 with full WOL (Wake On LAN), one with PXE support

One 10/100 iLO NIC dedicated to management

Two NICs are upgradable to 10/100/1000T using the Dual Gigabit Ethernet NC7780 NIC option kit

Hard Drives

Maximum Internal Storage

512MB PC133-MHz Registered ECC SDRAM DIMM Memory (2 X 256 MB)

(1 processor model)

Note: Memory must be installed in pairs.

Integrated Lights-Out (iLO) Management Advanced (ASIC on the System Board)

None ship standard

145.6 GB (internal drive cage) (2 x 72.8 GB Wide Ultra3, 1 ″ drives)

No PCI slots all features are integrated

To view the Product Demo, please see the following URL, then click on ″ PRODUCT DEMO ″ : http://www5.compaq.com/products/servers/proliant-bl/p-class/index.html

ProLiant BL p-Class Server Blade Enclosure and Interconnects

ProLiant BL p-Class Server

Blade Enclosure

6U (10.5-inch), 19-inch wide

Holds up to 8 ProLiant BL20p servers blades

10 bays per server blade enclosure

8 bays for server blades

2 outside bays for interconnect modules (RJ-45 patch panels or GbE interconnect switches)

Server blades blind mate into the server blade enclosure backplane for power and data connections

Up to 6 BL p-Class 6U server blade enclosures fit in a 42U rack

Server blade management module attached to the back of each BL p-Class 6U server blade enclosure to report events all servers and provide asset and inventory information

ProLiant BL p-Class Power

Requirements

Redundant 200V − 240V AC, 30 amp single-phase for

Redundant 208V 30amp 3-phase 4 wire

Redundant -48VDC ± 10%

3 DA-11411 North America — Version 7 — December 4, 2002

QuickSpecs

Standard Features

(Server Blade Enclosure & Interconnects)

ProLiant BL p-Class

ProLiant BL p-Class

Interconnect Switch Option

(Two switches per kit)

(Every BL p-Class server blade enclosure requires two Interconnect switches OR two

RJ-45 patch panels)

Provides up to a 32 to 1 server networking cable reduction per server enclosure. Each interconnect switch (two per enclosure) reduces sixteen 10/100 Base-T/Base-TX server network ports to four uplinks ports (eight uplinks total). Only one to all eight uplinks may be used per enclosure.

The ProLiant BL p-Class F-GbE Interconnect Kit includes two GbE interconnect switches and two DualTSX

Interconnect Modules that provide four (4) LC 1000 SX and four (4) RJ-45 10/100 T/TX uplink ports per server enclosure.

The ProLiant BL p-Class C-GbE Interconnect Kit includes two GbE interconnect switches and two QuadT

Interconnect Modules that provide four (4) RJ-45 10/100/1000 T/TX/T and four (4) RJ-45 10/100 T/TX uplink ports per server enclosure.

Also included (per Interconnect Switch):

• Two (2) RJ-45 10/100 T/TX front panel ports for management or additional uplinks

• One (1) RS-232 DB-9 front panel out-of-band management port

• Redundant 10/100 cross links ports connecting the two Interconnect Switches

• Redundant power and cooling inputs

• Hot-plug and hot- remove with configuration retention capability

• Power ON, management, and per port status and speed LED indicators

• Reset/power momentary push-button switch

• Compaq ProLiant BL Interconnect Switch Management Utilities and User Documentation CD

• Fully pre-configured for rapid deployment and immediate operation

ProLiant BL Interconnect Switch Management System and Utilities:

Full featured web-based interface, menu-driven console interface, Telnet, SNMP-based scripting utility and example scripts, SNMP and RMON MIBs, BootP and DHCP client, port mirroring, QoS packet prioritization, IGMP multicasting, and TFTP server utilities for management of interconnect switch

ProLiant BL p-Class RJ-45

patch panel

(Two patch panels per kit)

(Every BL p-Class server blade enclosure requires two Interconnect switches OR two

RJ-45 patch panels)

Required Network Cabling

6U (10.5-inch), Plugs into BL p-Class 6U server blade enclosures

Used to pass NIC signals from all server blades in server blade enclosure out as RJ-45 connections

Supports Gigabit Ethernet network controllers

16 RJ-45 connectors on the back of each BL p-Class 6U RJ-45 patch panel (32 RJ-45 connections per server blade enclosure)

10Base-T Categories 3, 4 or 5 UTP (100 meters)

EIA/TIA-568 100-ohm STP (100 meters)

100Base-TX Category 5 UTP (100 meters)

EIA/TIA-568 100-ohm STP (100 meters)

1000Base-T Category 5 UTP (100 meters)

EIA/TIA-568 100-ohm STP (100 meters)

1000Base-SX 50/125 µm Multimode Fiber, 400 MHz/Km (500 meters)

50/125 µm Multimode Fiber, 500 MHz/Km (550 meters)

62.5/125 µm Multimode Fiber, 160 MHz/Km (220 meters)

62.5/125 µm Multimode Fiber, 200 MHz/Km (275 meters)

Note: For cabling information, refer to the Web site at: http://www.compaq.com/products/servers/

4 DA-11411 North America — Version 7 — December 4, 2002

QuickSpecs

Standard Features

(Power System and Rack Information)

ProLiant BL p-Class

ProLiant BL p-Class Power

System and Rack Information

Note: To determine power configuration please refer to the ProLiant BL p-Class Overview and Planning

Whitepaper and sizing tool, please see the following URL: http://www.compaq.com/products/servers/proliant-bl/p-class/index.html

ProLiant BL p-Class Power

Enclosure

3U (5.25-inch), 19-inch wide, 29-inch deep (0.48-meter wide, 0.74-meter deep), Dual input single phase and three phase models available

BL p-Class power enclosure provides external, shared hot-plug power. Each three-phase power enclosure houses up to six hot-plug power supplies each single-phase power enclosures hold up to four hot-plug power supplies to power the BL p-Class server blades and interconnects

Please use the sizing utility to determine the power needed for each configuration. http://activeanswers.compaq.com/aaconfigurator/PowerCalc/BL20p.xls

Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If using facility DC, only Facility DC Power Connection kit part number (240563-B21) is needed.

BL p-Class Power Distribution In the ProLiant BL p-Class infrastructure, redundant -48 VDC power (from the power enclosures or facility DC power) is distributed from the power enclosures to the server blade enclosures through the Compaq bus bar system. Hinges attach the ProLiant BL bus bars to the rails in a rack. The bus bars swing open from the center to enable easy rear access to the server blades and network cables. Power is distributed redundantly through independent A- and B-sided bus bars.

Three different power distribution solutions are available depending on the maximum number of server blade enclosures planned for the rack:

Required Power Source

• Compaq ProLiant BL p-Class scalable bus bar

• Compaq ProLiant BL p-Class mini bus bar

Note: To support a full 42U rack of BL20p server blades (6 server blade enclosures), two mini bus bars are needed.

• Compaq ProLiant BL p-Class power bus box

Power Enclosures

Supported

Scalable Bus Bar 1 or 2

Mini Bus Bar

Power Bus Box

1

Server Blade Enclosures

Supported

≤ 5

≤ 3

Max. Rack Space

Occupied

36U

21U

1 1 9U

Two 30amp redundant power feeds per power enclosure

Connectors

–NEMA receptacles

1-phase L6-30, 250v, 30A 3-wire

3-phase L15-30, 250V, 30A, 4-wire

Optimized for power cabling from bottom and network cabling from top

For cabling information, refer to the Web site at http://www.compaq.com/products/servers/

5 DA-11411 North America — Version 7 — December 4, 2002

QuickSpecs

Standard Features

ProLiant BL p-Class

ProLiant Essentials Foundation

Pack Software

Optional ProLiant Essentials Value

Packs

Insight Manager 7

Optional software offerings that selectively extend the functionality of an

Adaptive Infrastructure to address specific business problems and needs:

• Rapid Deployment Pack – an automated solution for multi-server deployment and provisioning, enabling companies to quickly and easily

• adapt to changing business demands. complex environments, improving overall server utilization and enabling

Windows  2000 customers for the first time to confidently deploy multiple applications on a single multiprocessor ProLiant Server.

• Integrated Lights-Out Advanced Pack - The BL20p includes the advance version of the Integrated Lights-Out which includes graphical console and virtual media.

Insight Manager 7 helps maximize system uptime and performance and reduces the cost of maintaining the IT infrastructure by providing proactive notification of problems before those problems result in costly downtime and reduced productivity. Insight Manager 7 is easy to set up and provides rapid access to detailed fault and performance information gathered by the

Management Agents. One-click-access to the Remote Insight Lights Out

Edition board allows systems administrators to take full graphical control of

ProLiant servers in remote locations or lights-out data centers. Finally,

Insight Manager 7 in concert with the Version Control Agents and Version

Control Repository Manager enables systems administrators to version manage and update system software across groups of Compaq ProLiant servers.

Management Agents

ActiveUpdate

The Management Agents form the foundation for HP’s Intelligent

Manageability strategy. They provide direct, browser-based access to indepth instrumentation built into HP servers, workstations, desktops, and portables, and send alerts to Insight Manager 7 and other enterprise management applications in case of subsystem or environmental failures.

For additional information about the Management Agents and other management products from HP, please visit the management website at http://www.hp.com/servers/manage

ActiveUpdate is a web-based application that keep IT managers directly connected to HP for proactive notification and delivery of the latest software updates.

The latest software, drivers, and firmware fully optimized and tested for your

ProLiant server and options.

Compaq ROMPaq, support software, and configuration utilities

Survey Utility and diagnostics utilities

Compaq Health Driver

The most advanced configuration analysis, reporting and troubleshooting utilities used by HP and at your fingertips.

Health Drivers interface with the Integrated Lights-Out ASIC to provide system management support, including monitoring of server components, event logging and support for the Compaq Insight Management Agents. iLO Management Interface Driver The iLO Management Interface Driver provides access to the iLO management processor for Insight Management Agents. This interface is used to provide SNMP alert forwarding and management agent integration.

Note: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials .

6 DA-11411 North America — Version 7 — December 4, 2002

QuickSpecs

Standard Features

OS Support

ProLiant BL p-Class

Microsoft

LINUX

Windows 2000 Server and Advanced Server

(Red Hat

and SuSE

)

Microsoft .NET

 Server

Note: For a more complete and up-to-date listing of supported OS’s and versions, please visit our OS Support

Matrix at: ftp://ftp.compaq.com/pub/products/servers/os-support-matrix-310.pdf

.

Note: For an up-to-date listing of the latest drivers available for the Compaq ProLiant BL p-Class, please see: http://www.compaq.com/support/files/server/us/index.html

.

Intelligent Manageability Integrated Lights-Out Advanced (iLO)

Virtual Text and Graphical Remote Console *

Virtual Floppy *

Virtual Power Button Control

Dedicated LAN Connectivity

Automatic IP Configuration via DHCP/DNS/WINS

Industry Standard 128-bit Secure Sockets Layer (SSL) Security

IML and iLO Event Logging

Support for 12 user accounts with customizable access privileges

Automatic Server Recovery-2 (ASR-2)

Insight Manager 7

Redundant ROM

Remote Flash ROM

ROM Based Setup Utility (RBSU)

Advanced Configuration and Power Interface Specification Ready (ACPI)

Server Health Logs

Compaq Redundant Power Supply Utility

Pre-Failure Warranty (covers processors, as well as hard drives and memory)

Compaq Interconnect Switch Management System and Utilities (interconnect switch option)

Integrated Management Log (IML)

Off-Line Backup Processor capability

Dynamic sector repairing and drive parameter tracking (with Smart Array controllers)

Redundant/adaptive load balancing NIC Support

* Advanced features such as Graphical Remote Console and Virtual Floppy are included with the BL p-Class server.

Availability Power redundancy: Redundant AC feeds into power enclosures, redundant DC feeds from power enclosure to server blade enclosures, 1 + 1 redundant power supplies

Two hot-plug SCSI hard drive bays and integrated RAID (Smart Array 5i) on every server blade (Battery-backed write cache is optional.)

Redundant ROM on each server blade

ECC Memory

Interconnects Switch Availability

Hot-plug and hot- remove with configuration retention capability

Two network connections per server blade bay (four NICs total) routed to two redundant interconnect switches

Redundant inter-switch communication with two sets of redundant uplink ports per each interconnect switch

IEEE 802.1D Spanning tree protocol support for loop-free path redundancy

Static IEEE 802.3ad (EtherChannel compatible) trunking with automatic port load balancing

Network adapter teaming (network fault tolerance, transmit load balancing, switch-assisted load balancing)

7 DA-11411 North America — Version 7 — December 4, 2002

QuickSpecs

Standard Features

Security

ProLiant BL p-Class

Power-on password

Administrator's password

Integrated Lights-Out has 12 customizable user accounts and SSL encryption

Integrated Lights-Out can be disabled via a Global Setting

Interconnect Switch multilevel user names and passwords and management interface time out period setting

Up to 64 Port-based IEEE 802.1Q tagged VLANs per interconnect switch

Minimum Rack Requirements Mounts in Compaq, and Telco racks and Third Party racks that meet the following criteria:

• Compatible with 19-inch Standard EIA rail sets

• EIA rail-to-rail depth is 29 − 30 ″

• Cabinet depth must be at least 36-inch deep overall (Additional min. 3.5-inch clearance from rear

RETMA rail to rear door, inclusive in the 36-inch overall depth)

• Ample room for top and bottom cable egress (approximately 8 square inches for full rack configuration

• Must be capable of supporting 1600 lb (for full rack configuration)

• Perforated front and rear doors to accommodate front-to-back cooling

• Must have 65% open perforation on server blade enclosure doors to support airflow requirements

• Optimized for use with the Compaq 10000 Series racks

Note: If using Compaq 7000 Series rack, Compaq Rack Extension Kit and High Air Flow Rack Door options are required.

Rack Airflow Requirements • Rack 9000 and 10000 series Cabinets

The increasing power of new high-performance processor technology requires increased cooling efficiency for rack-mounted servers. The Compaq 9000 Series and 10000 Series Racks provides enhanced airflow for maximum cooling, allowing these racks to be fully loaded with servers using the latest processors.

• Rack 7000 series Cabinets

When installing a server with processors running at speeds of 550 MHz or greater in Compaq Rack

7000 series racks with glass doors (165753-001 (42U), and 163747-001 (22U)), the new processor technology requires the installation of High Airflow Rack Door Inserts (327281-B21 (42U), 327281-B22

(42U 6 pack), or 157847-B21 (22U)) to promote enhanced airflow for maximum cooling.

CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment: o o

Front and rear doors: If your 42U server rack includes closing front and rear doors, you must allow 830 square inches (5,350 sq cm) of hole evenly distributed from top to bottom to permit adequate airflow (equivalent to the required 64 percent open area for ventilation).

Side: The clearance between the installed rack component and the side panels of the rack must be a minimum of 2.75 inches (7 cm).

CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage.

Note: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the server, or to the server documentation located in the Support section at the following URL: http://www5.compaq.com/products/servers/proliantdl380/index.html

.

8 DA-11411 North America — Version 7 — December 4, 2002

QuickSpecs

Standard Features

Service and Support

ProLiant BL p-Class

HP Services provides a three-year, limited warranty, including Pre-Failure Warranty (coverage of hard drives, memory and processors) fully supported by a worldwide network of resellers and service providers. HP technical assistance is available 7x24, toll free in the United States and Canada. Telephone support services may be covered under warranty or available for an additional fee.

Note: Sever Blade Limited Warranty includes 3 year Parts, 3 year Labor, 3-year on-site support.

Note: Server Blade Enclosure and Interconnects Limited Warranty includes 3 year Parts, 3 year Labor, 3-year on-site support.

A full range of CarePaq  packaged hardware and software services:

• Installation and start up

• Extended coverage hours and enhanced response times

• System management and performance services

• Availability and recovery services

Note: For more information, customer/resellers can contact http://www.compaq.com/services .

Please see the following URL regarding Warranty Information For Your Proliant Products: http://www.compaq.com/support/warranty_upgrades/web_statements/176738.html

For additional information regarding Worldwide Limited Warranty and Technical Support, please see the following

URL: ftp://ftp.compaq.com/pub/supportinformation/ejourney/176738.pdf

.

Note: Certain restrictions and exclusions apply. Consult the Customer Support Center at 1-800-345-1518 for details.

DA-11411 North America — Version 7 — December 4, 2002 9

QuickSpecs

Models

ProLiant BL20p P1400-512KB,

512MB (1P)

230040-B21

Processor(s)

Cache Memory

Memory

Network Controller

Storage Controller

Hard Drives

Internal Storage

Optical Drive

Form Factor

ProLiant BL p-Class

(1) Intel Pentium III 1.40 GHz standard (up to 2 supported)

512-KB Level 2 writeback per processor

512 MB (Standard) (2 X 256MB) to 4096 MB PC133-MHz Registered ECC

SDRAM DIMM Memory

Three Compaq NC3163 Fast Ethernet NIC PCI 10/100 with full WOL (Wake On

LAN); one NIC has PXE support

One additional 10/100 port dedicated to iLO Management

Smart Array 5i Controller (integrated on system board)

None ship standard

Up to 145.6-GB maximum (with optional hard drives)

None

Plugs vertically into Compaq ProLiant BL p-Class Server Blade Enclosure

DA-11411 North America — Version 7 — December 4, 2002 10

QuickSpecs

Options

ProLiant BL p-Class

ProLiant BL20p Unique Options Dual NC7780 Gigabit Upgrade Module for ProLiant BL20p

Note: The Dual NC7780 Gigabit Upgrade Module replaces two of the standard NC3163

Fast Ethernet Embedded WOL (Wake On LAN) NICs to two 10/10/1000T

NC7780 NICs.

Note: The GbE Interconnect Switch options support server NIC speeds to 100 Mbps. It is recommended that the patch panel be used with the Dual NC7780 Gigabit

Upgrade Module if server NIC speeds to 1000 Mbps are required.

ProLiant BL p-Class Server Blade Enclosure (ProLiant Essentials Rapid Deployment

Pack Trial)

ProLiant BL p-Class Server Blade Enclosure (8 ProLiant Essentials Rapid Deployment

Pack Licenses)

ProLiant BL p-Class RJ-45 Patch panel (pair)

Note: Only one interconnect kit required per server blade enclosure.

ProLiant BL p-Class C-GbE Interconnect Kit (with pair of GbE Interconnect Switches and two QuadT Interconnect Modules)

Note: Only one interconnect kit required per server blade enclosure.

Note: To meet applicable radio frequency (RF) emission limits, the sidewall panels on the ends of any individual rack or a series of coupled racks and the front and rear doors must be installed in any racks containing more than one ProLiant BL p-

Class GbE Interconnect Kit.

ProLiant BL p-Class F-GbE Interconnect Kit (with pair of GbE Interconnect Switches and two DualTSX Interconnect Modules)

Note: Only one interconnect kit required per server blade enclosure.

Note: To meet applicable radio frequency (RF) emission limits, the sidewall panels on the ends of any individual rack or a series of coupled racks and the front and rear doors must be installed in any racks containing more than one ProLiant BL p-

Class GbE Interconnect Kit.

Single Phase Redundant Power Enclosure with 4 power supplies

(Single Phase Power Enclosure holds a maximum of 4 power supplies; no need to order additional power supplies with this option kit)

3 Phase Redundant Power Enclosure with 6 power supplies

(3 Phase Power Enclosure holds a maximum of 4 power supplies; no need to order additional power supplies with this option kit)

Single Phase Power Enclosure (empty)

(Holds up to 4 power supplies; power supplies are not included in this kit)

3 Phase Power Enclosure (empty)

(Holds up to 6 power supplies; power supplies are not included in this kit)

Single Power Supply

Facility DC Power Connection

ProLiant p-Class Scalable Bus Bar

ProLiant p-Class Mini Bus Bar

ProLiant p-Class Bus Power Box

230255-B21

243564-B21

281404-B21

230766-B21

249655-B21

279720-B21

239162-001

230769-001

231710-001

231709-001

239161-B21

240563-B21

240560-B21

240559-B21

240562-B21

11 DA-11411 North America — Version 7 — December 4, 2002

QuickSpecs

Options

ProLiant BL p-Class

ProLiant Essentials Value Pack

Software

Processor

Memory (SDRAM DIMMs)

Hard Drives

Storage Controllers

Rapid Deployment Pack, 10 User, V1.x

Note: This license allows 10 servers to be managed and deployed via the Deployment

Server.

Note: Not necessary if you purchase the server blade enclosure with 8 Rapid

Deployment Pack licenses 281404-B21.

Rapid Deployment Pack, 1 User, V1.x

Note: This license allows 1 server to be managed and deployed via the Deployment

Server.

Note: Not necessary if you purchase the server blade enclosure with 8 Rapid

Deployment Pack licenses 281404-B21.

ProLiant Essentials Workload Management Pack (Featuring Resource Partitioning

Manager version 2.0)

269817-B21

267196-B21

303284-B21

Note: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials

Note: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to URL http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials Value Pack product

QuickSpecs for more information.

Note: These Web sites are available in English only.

234277-B21 Pentium lll P1400-512KB Processor Option Kit

2048 MB PC133MHz Registered ECC SDRAM Memory Kit (2x1024 MB)

1024 MB PC133MHz Registered ECC SDRAM Memory Kit (2x512 MB)

512 MB PC133MHz Registered ECC SDRAM Memory Kit (2x256 MB)

256 MB PC133MHz Registered ECC SDRAM Memory Kit (2x128 MB)

201695-B21

201694-B21

201693-B21

201692-B21

Ultra 320 SCSI – Universal Hot Plug

36.4GB 10,000 rpm, U320 Universal Hard Drive, 1 ″ 286713-B22

72.8GB 10,000 rpm, U320 Universal Hard Drive, 1 ″ 286714-B22

18.2GB 15,000 rpm, U320 Universal Hard Drive, 1 ″ 286775-B22

36.4GB 15,000 rpm, U320 Universal Hard Drive, 1 ″ 286776-B22

72.8GB 15,000 rpm, U320 Universal Hard Drive, 1 ″ 286778-B22

Note: All U320 Universal Hard Drives are backward compatible to U2 or U3 speeds.

Wide Ultra3 SCSI – Universal Hot Plug

72.8-GB Wide Ultra3 SCSI 10,000 rpm Drive (1 ″ )

36.4-GB Wide Ultra3 SCSI 10,000 rpm Drive (1 ″ )

18.2-GB Wide Ultra3 SCSI 10,000 rpm Drive (1 ″ )

36.4-GB Wide Ultra3 SCSI 15,000 rpm Drive (1 ″ )

18.2-GB Wide Ultra3 SCSI 15,000 rpm Drive (1 ″ )

Battery Backed Write Cache Enabler Option Kit

232432-B22

176496-B22

142673-B22

232916-B22

188122-B22

255514-B21

Note: Please see the following Controller QuickSpecs for Technical Specifications such as PCI Bus, PCI Peak

Data Transfer Rate, SCSI Protocols supported, SCSI Peak Data Transfer Rate, Channels, SCSI Ports,

Drives supported, Cache, RAID support, and additional information: http://www5.compaq.com/products/quickspecs/11063_div/11063_div.HTML

(Smart Array 5i Plus)

12 DA-11411 North America — Version 7 — December 4, 2002

QuickSpecs

Options

Communications

BL p-Class Server Blade

Enclosures

BL p-Class Interconnects

BL p-Class Power options

Power Distribution

Diagnostic Options

ProLiant BL p-Class

Dual NC7780 Gigabit Upgrade Module for ProLiant BL20p

Note: The Dual NC7780 Gigabit Upgrade Module replaces two of the standard NC3163

Fast Ethernet Embedded WOL (Wake On LAN) NICs to two 10/10/1000T

NC7780 NICs.

Note: The GbE Interconnect Switch options support server NIC speeds to 100 Mbps. It is recommended that the patch panel be used with the Dual NC7780 Gigabit

Upgrade Module if server NIC speeds to 1000 Mbps are required.

ProLiant BL p-Class Server Blade Enclosure (ProLiant Essentials Rapid Deployment

Pack Trial)

ProLiant BL p-Class Server Blade Enclosure (8 ProLiant Essentials Rapid Deployment

Pack Licenses)

ProLiant BL p-Class RJ-45 Patch panel (pair)

Note: Only one interconnect kit required per server blade enclosure.

ProLiant BL p-Class C-GbE Interconnect Kit (with pair of GbE Interconnect Switches and two QuadT Interconnect Modules)

Note: Only one interconnect kit required per server blade enclosure.

Note: To meet applicable radio frequency (RF) emission limits, the sidewall panels on the ends of any individual rack or a series of coupled racks and the front and rear doors must be installed in any racks containing more than one ProLiant BL p-

Class GbE Interconnect Kit.

ProLiant BL p-Class F-GbE Interconnect Kit (with pair of GbE Interconnect Switches and two DualTSX Interconnect Modules)

Note: Only one interconnect kit required per server blade enclosure.

Note: To meet applicable radio frequency (RF) emission limits, the sidewall panels on the ends of any individual rack or a series of coupled racks and the front and rear doors must be installed in any racks containing more than one ProLiant BL p-

Class GbE Interconnect Kit.

Note: Use p-Class sizing tool to help determine power configuration: http://activeanswers.compaq.com/aaconfigurator/PowerCalc/BL20p.xls

Single Phase Redundant Power Enclosure with 4 power supplies

(Single Phase Power Enclosure holds a maximum of 4 power supplies; no need to order additional power supplies with this option kit)

3 Phase Redundant Power Enclosure with 6 power supplies

(3 Phase Power Enclosure holds a maximum of 4 power supplies; no need to order additional power supplies with this option kit)

Single Phase Power Enclosure (empty)

(Holds up to 4 power supplies; power supplies are not included in this kit)

3 Phase Power Enclosure (empty)

(Holds up to 6 power supplies; power supplies are not included in this kit)

Single Power Supply

Facility DC Power Connection

ProLiant p-Class Scalable Bus Bar

ProLiant p-Class Mini Bus Bar

ProLiant p-Class Bus Power Box

ProLiant p-Class Diagnostic Station

Note: The Diagnostic Station allows access to the ProLiant BL20p server blade and the

BL p-Class interconnect switch outside of the server enclosure. The option provides power and a data interface so that "offline" upgrade and diagnostic functions may be performed.

230255-B21

243564-B21

281404-B21

230766-B21

249655-B21

279720-B21

239162-001

230769-001

231710-001

231709-001

239161-B21

240563-B21

240560-B21

240559-B21

240562-B21

230743-B21

13 DA-11411 North America — Version 7 — December 4, 2002

QuickSpecs

Options

ProLiant BL p-Class

Compaq Rack 10000 Series

(Graphite Metallic)

Compaq Rack 9000 Series (Opal)

Compaq Rack 10842 (42U) – Pallet 257415-B21

Compaq Rack 10842 (42U) – Shock Pallet 257415-B22

Compaq Rack 10647 (47U) – Pallet 245160-B21

Compaq Rack 10647 (47U) – Crated 245160-B23

Compaq Rack 10642 (42U) – Pallet 245161-B21

Compaq Rack 10642 (42U) – Shock Pallet 245161-B22

Compaq Rack 10642 (42U) – Crated 245161-B23

Compaq Rack 10636 (36U) – Pallet 245162-B21

Compaq Rack 10636 (36U) – Shock Pallet 245162-B22

Compaq Rack 10636 (36U) – Crate 245162-B23

Compaq Rack 10622 (22U) – Pallet 245163-B21

Compaq Rack 10622 (22U) – Shock Pallet 245163-B22

Compaq Rack 10622 (22U) – Crated 245163-B23

Note: -B21 (pallet) used to ship empty racks shipped on a truck

-B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels)

-B23 (crated) used for air shipments of empty racks

Not all Compaq equipment is qualified to be shipped in the Rack 10000 series.

Note: Please see the Rack 10000 QuickSpecs for Technical Specifications such as height, width, depth, weight, and color: http://www5.compaq.com/products/quickspecs/10995_na/10995_na.HTML

Note: For additional information regarding Rack Cabinets, please see the following URL: http://www.compaq.com/racks

Compaq Rack 9142 (42U) – Pallet 120663-B21

Compaq Rack 9142 (42U) – Shock Pallet 120663-B22

Compaq Rack 9142 (42U) – Crated 120663-B23

Compaq Rack 9136 (36U) – Pallet 120664-B21

Compaq Rack 9136 (36U) – Shock Pallet 120664-B22

Compaq Rack 9136 (36U) – Crated 120664-B23

Compaq Rack 9122 (22U) – Pallet 120665-B21

Compaq Rack 9122 (22U) – Shock Pallet 120665-B22

Compaq Rack 9122 (22U) – Crated 120665-B23

Compaq Rack 9842 (800mm wide, 42U) - Pallet 222192-B21

Note: -B21 (pallet) used to ship empty racks shipped on a truck

-B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels)

-B23 (crated) used for air shipments of empty racks

Note: Please see the Rack 10000 QuickSpecs for Technical Specifications such as height, width, depth, weight, and color: http://www5.compaq.com/products/quickspecs/10366_na/10366_na.HTML

Note: For additional information regarding Rack Cabinets, please see the following URL: http://www.compaq.com/racks

14 DA-11411 North America — Version 7 — December 4, 2002

QuickSpecs

Options

ProLiant BL p-Class

Rack Options for Compaq Rack

10000 Series

Rack Options for Compaq Rack

9000 Series

Rack Blanking Panels – Graphite (Multi)

Note: Contains one each of 1U, 2U, 3U and 4U panel.

Rack Blanking Panels – Graphite (1U)

Note: The Rack Blanking Panels (PN 253214-B21) contains 10 each of (1U).

Rack Blanking Panels – Graphite (2U)

Note: The Rack Blanking Panels (PN 253214-B22) contains 10 each of (2U).

Rack Blanking Panels – Graphite (3U)

Note: The Rack Blanking Panels (PN 253214-B23) contains 10 each of (3U).

Rack Blanking Panels – Graphite (4U)

Note: The Rack Blanking Panels (PN 253214-B24) contains 10 each of (4U).

Rack Blanking Panels – Graphite (5U)

Note: The Rack Blanking Panels (PN 253214-B25) contains 10 each of (5U).

800mm Stabilizer Option Kit (Graphite)

Note: The 800mm Stabilizer Kit (PN 255488-B21) supports the Rack 9842 only.

600mm Stabilizer Kit – Graphite

Baying Kit for Rack 10000 series (Carbon)

42U Side Panel – Graphite Metallic

110V Fan Kit (Graphite)

Note: Roof Mount Includes power cord with IEC320-C13 to NEMA 5-15P.

220V Fan Kit (Graphite)

Note: Roof Mount Includes power cord with IEC320-C13 to NEMA 6-15P.

36U Side Panel – Graphite Metallic

47U Side Panel – Graphite Metallic

9000/10000 Series Offset Baying Kit (42U)

Note: This kit can be used to connect 9000 and 10000 series racks of the same height together. Kit contents include hardware for connecting racks and a panel to cover the 100mm gap at the rear of the two racks.

Note: For additional information regarding Rack Cabinets, please see the following URL: http://www.compaq.com/racks

Baying/Coupling Kit

42U Side Panel

Note: The 42U Side Panel (PN 120670-B21) supports the Compaq Rack 9142 and

Compaq Rack 9842.

36U Side Panel

Note: The 36U Side Panel (PN 120671-B21) supports the Compaq Rack 9136.

600mm Stabilizer Option Kit

800mm Stabilizer Option Kit (Opal)

Note: The 800mm Stabilizer Kit (PN 234493-B21) supports the Rack 9842 only

Grounding Rack Option Kit

Stabilizer Option Kit

Rack Blanking Panel (Multi)

Note: Kit includes four panels in 1U, 2U, 4U, and 8U.

9142 Extension Kit

Note: The 9142 Extension Kit (PN 120679-B21) supports the Compaq Rack 9142 only.

246107-B21

248929-B21

246099-B21

257413-B21

257414-B21

246102-B21

255486-B21

248931-B21

120669-B21

120670-B21

120671-B21

120673-B21

234493-B21

120682-B21

120673-B21

169940-B21

120679-B21

253214-B26

253214-B21

253214-B22

253214-B23

253214-B24

253214-B25

255488-B21

15 DA-11411 North America — Version 7 — December 4, 2002

QuickSpecs

Options

ProLiant BL p-Class

Rack Options for Compaq Rack

9000 Series (continued)

Rack Options for Compaq Rack

7000 Series and Telco racks

Rack Options for Compaq Rack

10000, 9000 and 7000 Series

Rack Options for Telco Racks

Rack Blanking Panels (1U)

Note: The Rack Blanking Panels (PN 189453-B21) contains 10 each of (1U).

Rack Blanking Panels (2U)

Note: The Rack Blanking Panels (PN 189453-B22) contains 10 each of (2U).

Rack Blanking Panels (3U)

Note: The Rack Blanking Panels (PN 189453-B23) contains 10 each of (3U).

Rack Blanking Panels (4U)

Note: The Rack Blanking Panels (PN 189453-B24) contains 10 each of (4U).

Rack Blanking Panels (5U)

Note: The Rack Blanking Panels (PN 189453-B25) contains 10 each of (5U)

9136 Extension Kit

9142 Short Rear Door

Note: The 9142 Short Rear Door (PN 218217-B21) supports the Compaq Rack 9142 only.

Split Rear Door (Opal)

Note: The Split Rear Door (PN 254045-B21) supports the 600 mm wide, 42U 9000 series rack.

9136 Short Rear Door

9142 Split Rear Door

9000/10000 Series Offset Baying Kit

Note: This kit can be used to connect 9000 and 10000 series racks in 42U height together. Kit contents include hardware for connecting racks and a panel to cover the 100mm gap at the rear of the two racks.

Note: For additional information regarding Rack Cabinets, please see the following URL: http://www.compaq.com/racks

High Air Flow Rack Door Insert for 7122

High Air Flow Rack Door Insert for 7142 (single)

High Air Flow Rack Door Insert for 7142 (6-pack)

Compaq Networking Cable Management Kit

Compaq Networking Recessed Rail Management Kit

Compaq Rack Extension Kit for 7142

Note: For additional information regarding Rack Cabinets, please see the following URL: http://www.compaq.com/racks

Monitor Utility Shelf

Ballast Option Kit

100kg Sliding Shelf

Rack Rail Adapter Kit (25 ″ depth)

Monitor/Utility Shelf - Graphite

Depth Adjustable Fixed Rail

Cable Management D-Rings Kit

Console Management Controller (CMC) Option Kit

Console Management Controller (CMC) Sensors Option Kit

Console Management Controller (CMC) Locking Option Kit

Console Management Controller (CMC) Smoke Sensor Option Kit

Note: For additional information regarding Rack Cabinets, please see the following URL: http://www.compaq.com/racks

Bus Bar Telco Rail Option Kit

Enclosure Telco Rail Option Kit

254045-B21

218218-B21

254045-B21

248931-B21

157847-B21

327281-B21

327281-B22

292407-B21

292406-B21

154392-B21

245249-B21

266076-B21

303606-B21

120672-B21

234672-B21

120675-B21

253449-B21

332558-B21

168233-B21

203039-B21

203039-B22

203039-B23

203039-B24

189453-B21

189453-B22

189453-B23

189453-B24

189453-B25

218216-B21

218217-B21

16 DA-11411 North America — Version 7 — December 4, 2002

QuickSpecs

Options

Service and Support Offerings

(CarePaq Services)

ProLiant BL p-Class

Hardware Services 4-Hour On-site Service

3 yrs, 9x5, on-site hardware maintenance with a 4-hour response for a fully configured

ProLiant BL p-Class server blade enclosure with interconnects and up to 8 server blades, power enclosure with power supplies and power distribution. (6-3 part number for US)

3 yrs, 24x7, on-site hardware maintenance with a 4-hour response for a fully configured

ProLiant BL p-Class server blade enclosure with interconnects and up to 8 server blades, power enclosure with power supplies and power distribution. (6-3 part number for US)

3 yrs, 9x5, on-site hardware maintenance with a 4-hour response for a fully configured

ProLiant BL p-Class server blade enclosure with interconnects and up to 8 server blades, power enclosure with power supplies and power distribution. Electronic

CarePaq service. (6-3 part number for US)

3 yrs, 24x7, on-site hardware maintenance with a 4-hour response for a fully configured

ProLiant BL p-Class server blade enclosure with interconnects and up to 8 server blades, power enclosure with power supplies and power distribution. Electronic

CarePaq service. (6-3 part number for US)

Installation & Start-up Services

Install ProLiant BL p-Class server blade enclosure including up to 8 ProLiant BL p-Class server blades and interconnects, power enclosure with power supplies and power distribution. (6-3 part number for US)

Install ProLiant BL p-Class server blade enclosure including up to 8 ProLiant BL p-Class server blades and interconnects, power enclosure with power supplies and power distribution. Electronic CarePaq service. (6-3 part number for US)

Provides for the Installation and Start-up of Rapid Deployment Pack on a Customer supplied server designated as a Deployment Server. Includes the deployment of a single server. This new server will be deployed using either one of the pre-configured scripts or an image. In addition, the service will provide for the capture and storage of the configuration of the newly deployed server and orientation on product usage. To be delivered during standard office ours, standard office days. (6-3 part number for US)

Note: For more information, customer/resellers can contact http://www.compaq.com/services .

274369-002

274370-002

302329-001

302330-001

274371-002

302331-001

274545-002

DA-11411 North America — Version 7 — December 4, 2002 17

QuickSpecs

Memory

ProLiant BL20p Server Blade (1P Model)

ProLiant BL p-Class

S TANDARD M EMORY

512-MB PC133 MHz Registered ECC SDRAM DIMM installed (2 x 256-MB SDRAM DIMM)

S TANDARD M EMORY P LUS O PTIONAL M EMORY

Up to 2560-MB of SDRAM DIMM memory is available with the installation of optional SDRAM DIMM memory expansion kits.

S TANDARD M EMORY R EPLACED WITH O PTIONAL M EMORY

Up to 4096-MB of SDRAM DIMM memory is available with the removal of standard memory and the installation of optional SDRAM DIMM memory expansion kits.

Memory Slot

MB

MB

1 2

256 MB

256 MB

1024 MB

Following are memory options available from Compaq:

256 MB

256 MB

1024 MB

• 2048-MB PC133MHz Registered ECC SDRAM Memory Kit (2 x 1024 MB)

• 1024-MB PC133MHz Registered ECC SDRAM Memory Kit (2 x 512 MB)

• 512-MB PC133MHz Registered ECC SDRAM Memory Kit (2 x 256 MB)

• 256-MB PC133MHz Registered ECC SDRAM Memory Kit (2 x 128 MB)

3

Empty

1024 MB

1024 MB

4

Empty

1024 MB

1024 MB

201695-B21

201694-B21

201693-B21

201692-B21

DA-11411 North America — Version 7 — December 4, 2002 18

QuickSpecs

Technical Specifications

ProLiant BL p-Class

Compaq ProLiant BL p-Class

Server Blade Enclosure

Dimensions

Input Specifications

Individual server blade bay ratings

Temperature range

Relative humidity

(non-condensing)

Wet bulb temperature

Height

Width

Depth

Rated input voltage

Rated input current

Rated input Power

Rated input voltage

Rated input current

Rated input Power

Operating

Non-Operating

Operating

Non-Operating

Operating

Non-Operating

10.5 in/26.67 cm

17.60 in/44.70 cm

28.86 in/73.30 cm

-43 VDC to -53 VDC Nominal -48 VDC

62.5 A at -48 VDC

3000 W

-43 VDC to -53 VDC Nominal -48 VDC

6.25 A at -48 VDC

300 W

50° to 95° F/10° to 35° C

-22° to 140° F/-30° to 60° C

20% to 80%

5% to 95%

82.4° F/28° C

101.7° F/38.7° C

Operating and Performance

Specifications for ProLiant BL20p

Server Blade

Note: Operating temperature has an altitude derating of 34° F/1° C per 1,000 ft/304.8 m. No direct sunlight.

Upper operating limit is 10,000 ft/3,048 m or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft/9,144 m or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of

113° F/45° C. Altitude maximum for storage is 70 KPa.

Dimensions Height 1.69 in/4.29 cm

Width

Depth

10.29 in/26.14 cm

28.00 in/71.12 cm

Weight (maximum)

Temperature range

Relative humidity

(non-condensing)

Maximum wet bulb temperature

18.0 lb/8.17 kg

Operating

Non-operating

Shipping

Storage

Operating

Non-operating

Shipping

Storage

82° F/28° C

50° to 95° F/10° to 35° C

-40° to 140° F/-40° to 60° C

-4° to 140° F/-20° to 60° C

10% to 90%

10% to 90%

10% to 95%

Note: Operating temperature has an altitude derating of 34° F/1° C per 1,000 ft/304.8 m. No direct sunlight.

Upper operating limit is 10,000 ft/3,048 m or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft/9,144 m or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of

113° F/45° C. Altitude maximum for storage is 70 KPa.

19 DA-11411 North America — Version 7 — December 4, 2002

QuickSpecs

Technical Specifications

Operating and Performance

Specifications for RJ-45 Patch

Panel

ProLiant BL p-Class

Dimensions

Capability

Network transfer rate

Connector

Cable support

Power requirements

Temperature range

Relative humidity (noncondensing)

Wet bulb temperature

Height

Width

Depth

IEEE 802.2, 802.3, 802.3u

10 Base-T (half-duplex)

10 Base-T (full-duplex)

100 Base-TX (half-duplex)

100 Base-TX (full-duplex)

10.405 in/26.43 cm

1.535 in/3.899 cm

27.697 in/70.35 cm

10 Mbps

20 Mbps

100 Mbps

200 Mbps

1000 Base-TX (full-duplex) 1000 Mbps

RJ-45

10 Base-TX

100 Base-TX

1000 Base-TX

Categories 3, 4, or 5 UTP (2 or 4 pair); up to

328 ft/100 m

Category 5 UTP (2 pair); up to 328 ft/100 m

Category 5E (4 pair); up to 328 ft/100 m

200 mA at + 5V DC; 500 mA at -48V

Operating 50° to 95° F/10° to 35° C

Non-operating -22° to 140° F/-30° to 60° C

Operating

Non-operating

Operating

Non-operating

20% to 80%

5% to 95%

82.4° F/28° C

101.7° F/38.7° C

Note: Operating temperature has an altitude derating of 34° F/1° C per 1,000 ft/304.8 m. No direct sunlight.

Upper operating limit is 10,000 ft/3,048 m or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft/9,144 m or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of

113° F/45° C. Altitude maximum for storage is 70 KPa.

20 DA-11411 North America — Version 7 — December 4, 2002

QuickSpecs

Technical Specifications

ProLiant BL p-Class

Operating and Performance

Specifications for Interconnect

GbE Switch

Dimensions Height 10.405 in/26.43 cm

Width 1.535 in/3.899 cm

Depth 27.697 in/70.35 cm

Weight

11.5 lb/5.2 kg per interconnect switch

Performance

3.2 Gbps Switching bandwidth per server enclosure

4.4 Gbps uplink bandwidth per server enclosure

9.6 Million pps aggregate throughput per server enclosure (64-byte packets)

Full-wire speed for all connections

Auto-negotiation and auto-sensing with full-duplex support

Forwarding mode

Store and forward

MAC Addresses

8,191 per interconnect switch; MAC address based filtering and MAC address packet priority configuring

Forwarding table age time

Maximum age: 10 to 9999 seconds; default: 3000 seconds

Memory

32MB Main, 6MB flash and 16MB packet buffer per interconnect switch

Compliance

IEEE 802.3, 802.3u, 802.3ab, 802.3z, 802.1D, 802.1p, 802.3ac, 802.3ad

(Static), 802.1Q, and 802.3x

SNMP v1 (RFC 1157) and RMON v1 (RFC 1757) groups 1, 2, 3, and 9

MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface MIB (RFC 2233), 801.1Q

MIB (RFC 2684), RMON1 MIB (RFC 1757) groups 1, 2, 3, and 9, and Ethernet

MIB (RFC1643)

Network transfer rate

10 Base-T (half-duplex) 10 Mbps

10 Base-T (full-duplex) 20 Mbps

100 Base-TX (half-duplex) 100 Mbps

100 Base-TX (full-duplex) 200 Mbps

1000 Base-TX (half-duplex) 1000 Mbps

1000 Base-TX (full-duplex) 2000 Mbps

1000 Base-SX (full-duplex) 2000 Mbps

Connector

EMI

Safety

Power requirements

Temperature range

RJ-45, DB-9 (C-GbE Interconnect Kit)

LC fiber, RJ-45, DB-9 (F-GbE Interconnect Kit)

FCC Class A

ICES-003 Class A

AS/NZS 3548 Class A

VCCI Class A

UL/CUL Listed Accessory

48V: 1050 mA, 50 W maximum (per interconnect switch)

Operating 50° to 95° F/10° to 35° C

Non-operating -22° to 140° F/-30° to 60° C

Relative humidity

(non-condensing)

Wet bulb temperature

Operating

Non-operating

Operating

Non-operating

20% to 80%

5% to 95%

82.4° F/28° C

101.7° F/38.7° C

Note: Operating temperature has an altitude derating of 34° F/1° C per 1,000 ft/304.8 m. No direct sunlight. Upper operating limit is 10,000 ft/3,048 m or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft/9,144 m or

30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of

113° F/45° C. Altitude maximum for storage is 70 KPa.

21 DA-11411 North America — Version 7 — December 4, 2002

QuickSpecs

Technical Specifications

Operating and Performance

Specifications for Power

Enclosures

ProLiant BL p-Class

Dimensions

Weights

Input requirements

Output voltage specifications

Ambient temperature

range (See note)

Relative humidity, non-condensing

(See note)

Wet bulb temperature

Height

Width

Depth

Single-Phase Model

5.25 in/13.34 cm

17.60 in/44.7 cm

27.15 in/68.96 cm

No hot-plug power supplies 47.5 lb/21.55 kg

All hot-plug power supplies 99.5 lb/45.13 kg

Three-Phase Model

5.25 in/13.34 cm

17.60 in/44.7 cm

27.15 in/68.96 cm

47.5 lb/21.55 kg

125.5 lb/56.93 kg

Rated input voltage

Rated input frequency

Rated input current per side

Power cord

200 VAC to 240 VAC

50 Hz to 60 Hz

24A

Rated input power per side 5760 W

200 VAC to 240 VAC line to line

50 Hz to 60 Hz

24A per phase

9976 W

1 NEMA L6-30P per side 1 NEMA L15-30 per side

Rated output voltage

Rated output current

Rated output power

Nominal power

-48.8 VDC to -54 VDC -48.8 VDC to -54 VDC

99A 170A

4298 W

4158 W at 208 VAC

8310 W

7202 W at 208 VAC

Operating

Shipping

Operating

Non-operating

50° to 95° F/10° to 35° C 50° to 95° F/10° to 35° C

-22° to 140°F/-30° to 60°C -22° to 140°F/-30° to 60°C

20% to 80%

5% to 95%

20% to 80%

5% to 95%

Operating

Non-operating

82.4° F/28° C

101.7° F/38.7° C

82.4° F/28° C

101.7° F/38.7° C

Note: Operating temperature has an altitude derating of 34° F/1° C per 1,000 ft/304.8 m. No direct sunlight. Upper operating limit is 10,000 ft/3,048 m or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft/9,144 m or

30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of

113° F/45° C. Altitude maximum for storage is 70 KPa.

22 DA-11411 North America — Version 7 — December 4, 2002

QuickSpecs

Technical Specifications

Operating and Performance

Specifications for Power

Distribution Devices

ProLiant BL p-Class

Power enclosures or facility

DC feeds supported

(3U each)

Power Bus Box Mini Bus Bar Scalable Bus Bar

1 1 2

Server blade enclosures

supported (6U each)

Total rack height of supported enclosures

Dimensions

Height

Width

Depth

Weight

Rated operating voltage

1 3 5

5.1 in/12.95 cm

3.6 in/9.14 cm each

3.25 in/8.26 cm

3.62 lb/1.64 kg

-43.2 VDC to -54 VDC

19.45 in/49.40 cm

19.74 in/50.14 cm

2.2 in/5.59 cm

13.2 lb/59.9 kg

-43.2 VDC to -54 VDC

48.57 in/123.37 cm

19.74 in/50.14 cm

2.2 in/5.59 cm

26 lb/11.79 kg

-43.2 VDC to -54 VDC

Max total power supported 3000 W

Total max input current at minimum voltage

69.44 A at -43.2VDC

Total max input current at nominal voltage

62.5 A at -48VDC

9000 W 15,000 W

208.32 A at -43.2 VDC 347.2 A at -43.2 VDC

(equivalent of 175A per feed)

187.5 A at -48 VDC 312.5 A at -48 VDC

(equivalent of 175A per feed)

Max local ambient temperature

149° F/65° C 149° F/65° C 149° F/65° C

Note: All systems support redundant A & B feeds. Scalable bus bar supports dual A and dual B feeds.

DA-11411 North America — Version 7 — December 4, 2002 23

QuickSpecs

Technical Specifications

Operating and Performance

Specifications for Facility DC

Voltage

ProLiant BL p-Class

Current

In-rush current

Nominal input voltage

Operating voltage range

Max Input voltage slew rate

Redundant feed voltages*

(A & B)

Ripple/Noise

Overshoot

-48 VDC

-48VDC ± 10% or -43.2 VDC to -52.8 VDC

0.5V/uS

* A and B feeds must differ by no more than

5VDC during steady state operation

480 mV PARD **

Must remain within regulation limits on all feeds during startup or shutdown

Must not exceed -60 VDC Voltage transients

Max steady state input current 62.5A per server blade enclosure installed at

-48VDC

Max steady state current per feed/total

Power bus boxes

Mini bus bars

Scalable bus bars

70 A/70A

210 A/210A

210 A/350A or equivalent of 175A per feed *

Must support up to 2X the maximum operating current per server blade enclosure (125 A) for up to 1.0 mS

Input over-current Customer provided fusing for facility DC feeds that protects the system from catastrophic over-current within 20 uS. Fuse should sustain all in-rush and operating currents.

Max Input Current Slew Rate 1A/uS

Max Rated Power

Connections and Cables

3000W per server blade enclosure

Compaq provided facility DC cable connection kit:

• The facility DC connection kit supports the connection of up to four -

48VDC, RETURN pairs and ground.

The power cable assemblies consist of 1/0AWG, color-coded, flexible cable rated at 105° C, terminated with bus mating connectors at one end and unterminated at the other end. The cable length provided enables the customer to route to a fuse panel within or adjacent to the rack.

Note: *All systems support redundant A and B feeds. Scalable bus bars support dual A and dual B feeds.

** Periodic and random noise (PARD). Maximum allowable peak-to-peak ripple and noise (as measured at the load on any output channel). The ripple and noise is measured over a 20 Hz to 100 MHz frequency band. A resistive load (non-electronic) is used for this measurement. Each output is by-passed to return by a 10uF tantalum capacitor with an ESR less than 100 milli-Ohms in parallel with a 0.47 uF ceramic capacitor, at the point of load. The load cable is 12 feet of twisted wire capable of carrying the current.

The printed wiring board assembly is installed in its enclosure for this measurement, or the measurement leads are properly shielded with Earth grounds applied to the insert.

© 2002 Hewlett-Packard Company

Hewlett-Packard, the Hewlett-Packard logo, CarePaq, Insight Manager, OpenVMS, ProLiant, StorageWorks, SmartStart, SANworks and Tru64 are trademarks of Hewlett-Packard Company in the U.S. and/or other countries. Microsoft, Microsoft.Net, and Windows are registered trademarks or trademarks of Microsoft Corporation in the U.S. and/or other countries. Intel and Pentium are registered trademarks or trademarks of Intel Corporation in the U.S. and/or other countries. Linux is a registered trademark or trademark of Linus Torvalds in the U.S. and/or other countries. Red Hat is a registered trademark or trademark of Red Hat Inc., in the U.S., and other countries. All other product names mentioned herein may be trademarks of their respective companies.

Hewlett-Packard shall not be liable for technical or editorial errors or omissions contained herein. The information is provided "as is" without warranty of any kind and is subject to change without notice. The warranties for Hewlett-Packard products are set forth in the express limited warranty statements accompanying such products. Nothing herein should be construed as constituting an additional warranty.

DA-11411 North America — Version 7 — December 4, 2002 24

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!