SANYO 2010 Full Product Brochure

SANYO 2010 Full Product Brochure
Room Air Conditioners
Commercial Split Systems
SANYO Air Conditioners. The natural choice.
Electric VRF
Gas Driven VRF
CO2 ECO Heating System
Hydronic Products
New Product Range 2009/10
Facing
the the
future
Facing
future
With increasing concern about the link between
carbon emissions and rising global temperatures,
the need to use energy more efficiently is becoming
ever more pressing.
SANYO is committed to developing environmentally
sustainable technologies
World powers are working together to tackle the problem
with international negotiations including UN Conferences,
Kyoto Mechanisms and the Intergovernmental Panel on
Climate Change. But although targets are set at national and
international level, behaviour must change on an individual
basis to have any hope of battling global warming.
The Virus Washer effectively
suppresses viruses, bacteria
and allergens
SANYO is the world
leader in solar PV cells
As individual consumers we are beginning to consider the
environmental impact of our buying decisions: choosing hybrid
cars, opting for recyclable packaging, considering food miles and increasingly scrutinising the homes we buy and the way
we heat them.
With the introduction of environmental legislation, such
as SAP building regulations and home information packs, in
future acting responsibility will become less of a choice for
the homeowner or builder and more of a necessity.
Highly efficient air
conditioning for heating
and cooling
Hybrid car batteries including Ford Galaxy and
Honda Accord
AQUA washing machine
uses ozone rather than
detergent
SANYO has continually stepped up to this challenge.
Its reputation as an innovator has been earned over years of
continuous research and development resulting in industry
leading products that have blazed a trail in terms of efficiency
and environmental sustainability. SANYO’s sustainable energy
solutions include Eneloop rechargeable batteries, hybrid car
batteries and solar power cells. In fact SANYO is a world leader
in the development of photovoltaic solar cells.
In 2005 SANYO announced its brand vision, ‘Think Gaia’. Gaia
is the mythical keeper of the earth and was the name chosen
by English Scientist James Lovelock to express the concept
of the earth as a single living organism where mankind and
all living things can coexist in harmony. SANYO is committed
to business practices and developing technologies that are
beneficial and not damaging to this harmonious relationship but
protect it for future generations.
SANYO Airconditioners The natural choice.
SANYO introduced heat pump air conditioners in 1960
and has continued to pioneer the industry ever since
with environmental technology innovations such as
the ECOi Electric VRF system, which dramatically
improved energy efficiency; the Gas-driven VRF system
with latest models that also generate hot water and
electricity; highly efficient water and floor heating with
the C02 ECO heat pumps and introducing this year the
PACi Hydronic Split System.
The challenge for manufacturers now is to provide sustainable
alternatives to traditional technologies.
Eneloop batteries can be
recharged 1000 times
The SANYO Solar Arc.
The world’s largest solar
power generator.
Product Overview 2009/10
Content
Room Air Conditioners
Room Air Conditioners – Content
Room Air Conditioners – Overview
Commercial Split Systems (PACI)
6
8
VRF Indoor Unit Range, ECOi & GHP
Electric VRF, ECOi
Commercial Split Systems (PACi) – Content42
Electric VRF, ECOi – Content
68
X type – semi-concealed cassette
98
PACi Commercial Split-Systems – Overview44
Electric VRF, ECOi – Overview
70
XM type – mini semi-concealed cassette 100
Shiki Sai Kan – wall mounted
10
PACi Range Overview
46
2Way ECOi
72
ADR type – semi-concealed cassette
102
Mini Shiki Sai Kan – wall mounted
12
PACi Hydronic Split Systems
48
2Way ECOi (continued)
74
SR type – semi-concealed cassette
104
KRV type – wall mounted
14
Elite PACi
50
3Way ECOi
76
LDR type – semi-concealed slim cassette106
XRV type – 4 way cassette
16
Classic PACi
51
3Way ECOi (continued)
78
DR type – concealed duct high-static pressure108
F/FT type – floor & ceiling mounted
18
KR type – wall mounted
52
Mini ECOi
80
US type – concealed duct
110
URV type – concealed duct
20
T type – ceiling mounted
54
VRF Indoor Unit Range
96
U type – concealed duct
112
KR type – wall mounted
22
X type – semi concealed
56
Convenient System Control
FTR type – floor/ceiling mounted
114
KR type (4 Series) – wall mounted
24
XM type – mini semi concealed
58
T type – ceiling mounted
116
XR type – 4 way cassette
26
XMR type – mini semi concealed
59
K type – wall mounted
118
F/FT type – floor & ceiling mounted
28
KR type – wall mounted
120
60
128
UR type – concealed duct
30
US & UMR type –
slim concealed duct & concealed duct
FR type – floor standing
122
Flexi Multi – Outdoor units
32
FTR type – floor/ceiling mounted
61
FMR type – concealed floor standing
124
Flexi Multi Indoor Unit Capacities
34
U type – concealed duct
62
GU type – Total Heat Exchanger
126
Flexi Multi Indoor Unit Capacities (continued)
6 3 Big PACi
Flexi Multi – 5 in 1
38 D type
Flexi Multi – 5 in 1 (continued)
40
Multi Systems
Convenient System Control
CO2 ECO Heating System
Hydronic Products
142
Hydronic Products – Content
154
CO2 ECO Heating System – Energy efficient
air to water heat pump technology
144
Water Chillers & Heat Pumps
156
SANYO CO2 ECO Tank Unit –
The complete heating management system051
Water Terminals
160
CO2 ECO Heating Domestic System
Water Terminals (continued)
162
Fan Coil Units
164
Ducted Units
166
CO2 ECO Heating System – Content
152
Water Chillers & Heat Pumps (continued)158
64
65
66
128
GAS driven VRF
GAS driven VRF – Content
82
Gas Heat Pumps, GHP – Overview
84
ECO G Power – GHP with generator
86
ECO G W-Multi
88
ECO G W-Multi (continued)
90
ECO G 3Way Multi – For simultaneous
heating and cooling operation
92
ECO G Water Heat Excanger –
for hydronic operations
94
VRF Indoor Unit Range
96
Convenient System Control
4
128
Convenient System Control
VRF and PACi
Convenient System Control –
for VRF (ECOi & GHP) and PACi
128
Individual Control Systems
130
Centralised Control Systems
132
Centralised Control Systems (continued) 134
Interfaces for external Control
136
BMS Software
138
PAC2 System Design Software
140
5
Room Air Conditioners
Content
Room Air
Conditioners
Room Air Conditioners – Overview 6
8
Inverter Systems
10
Constant Speed (On/Off ) Systems 22
Multi-Split Systems
32
7
Room Air Conditioners
The Room Air Conditioning range, specifically designed for
small to medium sized areas, is, like all our air conditioning
systems, the result of an extensive research and development
program developed since 1958. Our innovative products
offer the ideal solution when you need quiet, efficient room
air conditioning to create a comfortable environment within
a realistic budget. The latest generation of Residential Air
Conditioners (SAP models) are among the most technically
advanced and energy-efficient systems available today and are
backed by SANYO’s renowned reliability and customer service.
In addition to 1:1 Split systems, SANYO also produce the Flexi
Multi - an advanced range of R410A DC inverter Heat Pump
Multi Split Systems with up to 5 indoor units that can be
connected to an outdoor unit.
Energy Class
Energy
Air conditioning
Manufacturer
External Unit
Internal Unit
SAP
SAP
More Efficient
Annual energy consumption
The annual energy consumption
is calculated by multiplying the
consumptionatfullcoolingcapacity
by an average of 500 hours of
operation.
Annual energy consumption
in cooling mode KWh/year
Energy efficiency ratio
The higher the numerical value of
this ratio, the more efficient is the
air conditioning unit.
(Annual consumption depends on
climate and how the unit is used)
KW
Full load (the higher the better)
Type Cooling Only
Cooling + Heating
Benefits
Capacity (kW)
2.65
3.50
Shiki Sai Kan - wall mounted


Mini Shiki Sai Kan - wall mounted


KRV type - wall mounted

XRV type - 4 way cassette
Cost-effective running
Increased efficiency also means lower energy consumption and
lower operating costs for you.
The SAP range utilises the non‑ozone‑depleting R410A
refrigerant, which means you can benefit from a comfortable
environment without compromising the environment.
A: higher G: lower
Noise
(dB(A) re 1 pW)
Further information is contained in
product brochures.
5.10
7.10






F/FT - floor & ceiling mounted




URV type - concealed duct




Capacity (kW)
2.65
3.50
5.10
6.40
KR type - wall mounted


KR type (4 Series) - wall mounted




XR type - 4 way cassette



F/FT type - floor & ceiling mounted




UR type - concealed duct




Increased efficiency
Innovations in the system mean that the SANYO range of room
conditioners deliver market-leading efficiency.
Quiet operation
Constant Speed (On/Off ) systems
Our leading technology means you can enjoy the benefits of air
conditioning without the noise.
Stylish design
All our range is designed to look good in any environment, but
for the ultimate in style the new Shiki Sai Kan and Mini Shiki Sai
Kan come with a choice of front panels to match any interior
décor.
SANYO Air Conditioners provide comfort cooling and
heating
KW
Heating Performance
Inverter Systems
Environmentally friendly
Climate
Air Cooled
Water Cooled
Heat Output
Reference
Energy class
There are seven classes,
from “A” to “G”.
Less Efficient
Cooling output
Energy efficiency ratio
Product Type
Room Air Conditioners
Multi-Split systems
ABCDEFG
Product noise
Inside
Outside
Norm EN 814
Air-Conditioner
Energy Label Directive 2002/31/EC
Multiple combinations possible
Capacity (kW)
2.20
2.65
3.50
5.10
7.10






XMR type - 4 way cassette



F/FT type - floor & ceiling mounted




UMR type - concealed duct




Mini Shiki Sai Kan - wall mounted
K Type - wall mounted
8
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB

Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
9
Shiki Sai Kan
XXXXXXXXXXXXXXXXX
xxxxxxxxxxxxxxxxxxxx
wall
mounted
Room Air Conditioners
SAP-KRV...EHDX
SAP-CRV...EHDX
Cutting-edge technology, that includes the
industry’s top‑class energy-saving design, a
wide array of airflow control options and heating/
cooling operation down to -15°C.
SAP-CRV...EHDX
Remote
SAP-KRV...EHDX
Additional 6 stylish colour choices (options)
SPN-EXR(K) Black
• Amazing performance in energy-saving: COP up to 5.0
Air Clean Apatite Filter
• N
o reverse cycle defrost. Utilises hot gas injection defrosting,
for non-stop heating operation
Apatite or calcium phosphate is highly effective in trapping
germs, mites, pollen, dirt and dust, as well as cigarette odour.
The triple layered air clean apatite filter consists of antibacterial,
deodourising and dust collecting sections that maintain healthy,
clean air in your room.
• S leek & stylish panel design in a choice of 7 designer colours,
silver available as standard
• Super quiet mode: 22 dB(A)
• L ED photocatalytic sterilisation function features highperformance odour, germ and bacteria filters
• N
egative ions generator helps clean the air of pollutants and
is beneficial to health
Photocatalytic sterilisation
The light reclaimed sterilisation filter attracts airborne bacteria,
germs and allergens, and inactivates these pollutants with LED
irradiation.
Smell
• Air clean apatite filter
LED
• 3D air flow
Bacteria
• Cooling and heating down to -15°C
Light reclaimed sterilisation filter
• N
ight set back - economy mode function ensures gentle and
energy-saving cooling and heating
Negative Ions Generator
SPN-EXR(N) Gold
Indoor unit
Outdoor unit
System performance
Capacity
Power input
EER/COP
Energy class
Annual energy consumption
Running current
Power supply
SPN-EXR(T) Brown
SPN-EXR(R) Red
SPN-EXR(W) White
SAP-KRV94EHDX
SAP-CRV94EHDX
kW
W
kWh
A
V,ph,Hz
Indoor unit specifications
Air circulation
Moisture removal
Sound pressure level
Dimensions
Net weight
(H)
(H)
(Qt/L/M/H)
(H×W×D)
Outdoor unit specifications
Sound pressure level
Dimensions
Net weight
(H)
(H×W×D)
m3/h
Litres/h
dB(A)
mm
kg
dB(A)
mm
kg
SAP-KRV124EHDX
SAP-CRV124EHDX
Heating
Cooling
Heating
3,60 (0,9-5,5)
3,50 (0,9-4,2)
4,80 (0,9-6,0)
720 (250-1860)
875 (250-1700)
1140 (250-1860)
5,00
4,00
4,21
A
A
A
437,5
3,30 (1,6-8,5)
4,00 (1,6-7,8)
5,20 (1,6-8,5)
220-240V Single-Phase 50Hz (Outdoor unit)
Cooling
2,65 (0,9-3,8)
530 (250-1510)
5,00
A
265,0
2,4 (1,6-6,9)
600
1,8
22/30/38/39
22/30/38/40
300x898x200
12,5
49
50
630
2,0
22/30/38/40
22/30/38/41
300x898x200
12,5
50
51
569x790x285
40,0
569x790x285
40,0
6,35 (1/4)
9,52 (3/8)
15
10
7,5
15
10
6,35 (1/4)
9,52 (3/8)
15
10
7,5
15
10
Specifications subject to change without notice.
Installation data
• M
ultifunctional wireless remote control with built-in
temperature sensor
• A
utomatic retractable panel to improve air flow, efficiency and
reduce sound levels
SPN-EXR(D) Orange
3-D Air vent
3-D Air vent
mm(in.)
mm(in.)
m
m
m
g/m
A
Maximum piping length
Maximum elevation difference
Charge less piping length
Amount of additional refrigerant
Recommended fuse/circuit breaker capacity
Wide air flow
Airflow is directed so that
gentle warmth can
Wide
be felt in the
Circulation
entire room.
Airflow
Direct air flow
Airflow is directed to a desired spot.
Narrow
Wide
Pipe diameter
Built-in temperature sensor
The temperature sensor incorporated into the remote
control monitors the temperature around you.
Place the sensor remote control at your bedside so that you can
enjoy comfortable warmth throughout the night.
Temperature: 27˚C
Temperature: 30˚C
Temperature: 24˚C
Temperature: 27˚C
COLD
COMFORTABLE
With sensor remote control
No sensor remote control
Distribution of heat when temperature is set at 27˚C
10
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Outdoor
Indoor
Outdoor
Indoor
43°C DB
32°C DB
18°C WB
27°C DB
-15°C DB
19°C DB
-15°C WB
16°C DB
Energy class
A
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
R410A
11
Mini Shiki Sai Kan
wall mounted
Room Air Conditioners
SAP-KRV...EHDS
SAP-CRV...EHDS
Stylish & compact as well as offering an
exceptional energy-saving performance:
COP up to 4,21.
SAP-CRV...EHDS
Remote
SAP-KRV...EHDS
Additional 4 stylish colour choices (options)
SPN-DS(N) Gold
• Cooling and heating down to -15°C
Retractable panel
• T he LED photocatalytic sterilisation function ensures
excellent performance to combat odours, germs and
bacteria
During operation, the front panel of the air conditioning unit
opens to guarantee the optimal distribution of air across
the entire surface of the heat exchanger. This improves the
uniformity of the airflow, as well as functional efficiency and
operational noise levels. When the air conditioner is shut
off, the panel automatically returns to the closed position,
protecting the unit from dust.
• Automatic sweep control
• Apatite ceramic filter
• M
ultifunctional remote control with built-in temperature
sensor
• S imple elegant design with panels available in 5 colour
choice options.
• Clock with ON/OFF program timer
• Washable front panel
Photocatalytic sterilisation
• Low noise levels: 22 dB(A) (quiet mode)
The light reclaimed sterilisation filter attracts airborne bacteria,
germs and allergens, and inactivates these pollutants with LED
irradiation.
• N
ight set back/economy mode function ensures quiet and
energy-saving cooling and heating
SPN-DS(G) Green
Indoor unit
Outdoor unit
System performance
Capacity
Power input
EER/COP
Energy class
Annual energy consumption
Running current
Power supply
SPN-DS(W) White
SAP-KRV96EHDS
SAP-CRV96EHDS
kW
W
kWh
A
V,ph,Hz
Indoor unit specifications
Air circulation
Moisture removal
Sound pressure level
Dimensions
Net weight
(H)
(H)
(Qt/L/M/H)
(H×W×D)
Outdoor unit specifications
Sound pressure level
Dimensions
Net weight
(H)
(H×W×D)
m3/h
Litres/h
dB(A)
mm
kg
dB(A)
mm
kg
Cooling
2,51 (0,9-3,6)
600 (250-1040)
4,21
A
300,0
3,1 (1,29-5,38)
SAP-KRV126EHDS
SAP-CRV126EHDS
Heating
Cooling
Heating
3,14 (0,9-4,9)
3,50 (0,9-3,9)
4,80 (0,9-5,4)
970 (250-1400)
1025 (250-1200)
1260 (250-1600)
3,23
3,41
3,81
C
A
A
512,5
4,6 (1,21-6,76)
4,79 (1,17-5,61)
5,77 (1,14-7,32)
220-240V Single-Phase 50Hz (Outdoor unit)
480
1,6
22/28/35/41
500
22/28/35/41
510
2,0
22/28/35/42
265x789x180
9,5
45
560
22/29/36/42
265x789x180
9,5
46
47
565x790x265
36,0
48
565x790x265
36,0
Installation data
Smell
LED
Bacteria
Light reclaimed sterilisation filter
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Narrow
Wide
Pipe diameter
mm(in.)
mm(in.)
m
m
m
g/m
A
Maximum piping length
Maximum elevation difference
Charge less piping length
Amount of additional refrigerant
Recommended fuse/circuit breaker capacity
Outdoor
12
SPN-DS(L) Blue
Indoor
Outdoor
6,35 (1/4)
9,52 (3/8)
15
10
7,5
15
10
6,35 (1/4)
9,52 (3/8)
15
10
7,5
15
10
Specifications subject to change without notice.
Indoor
43°C DB
32°C DB
18°C WB
27°C DB
-15°C DB
19°C DB
-15°C WB
16°C DB
(except model 96)
Energy class
A
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
R410A
13
KRV type
wall mounted
Room Air Conditioners
SAP-KRV...EH
SAP-CRV...EH
Ideal solution when you need quiet, energyefficient and controllable room air conditioning.
SAP-CRV...EH
• New stylish appearance with compact flat panel design
• Cooling and heating down to -15°C (size 186 & 246)
• DC inverter technology for precise temperature control
• Auto restart after power failure and auto changeover
• Powerful start function for rapid cooling/heating
• Washable and reusable air clean apatite filter
• I nfrared remote control with 24 hour clock with ON/OFF
program time
• S leek multifunctional wireless remote control with built-in
temperature control
Remote
Indoor unit
Outdoor unit
System performance
Capacity
Power input
EER/COP
Energy class
Annual energy consumption
Running current
Power supply
SAP-KRV...EH
SAP-KRV96EH
SAP-CRV96EH
kW
W
kWh
A
V,ph,Hz
Indoor unit specifications
Air circulation
Moisture removal
Sound pressure level
Dimensions
Net weight
(H)
(H)
(Qt/L/M/H)
(H×W×D)
Outdoor unit specifications
Sound pressure level
Dimensions
Net weight
(H)
(H×W×D)
m3/h
Litres/h
dB(A)
mm
kg
dB(A)
mm
kg
Cooling
2,5 (0,9-3,2)
775 (250-1150)
3,23
A
387,5
3,92 (1,26-5,81)
Heating
3,3 (0,9-4,3)
915 (250-1360)
3,61
A
4,42 (1,21-6,57)
390
460
1,4
22/30/35/38
22/30/35/38
285x825x213
9
47
SAP-KRV126EH
SAP-KRV186EH
SAP-CRV126EH
SAP-CRV186EH
Cooling
Heating
Cooling
Heating
3,3 (0,9-3,8)
4,0 (0,9-5,0)
5,15 (1,2-5,5)
6,0 (1,3-6,4)
1025 (250-1300)
1105 (250-1470)
1500 (250-1800)
1575 (270-1930)
3,22
3,62
3,43
3,81
A
A
A
A
512,5
750
4,69 (1,14-5,95)
5,06 (1,14-6,73)
6,9 (1,2-8,4)
7,2 (1,3-9,0)
220-240V Single-Phase 50Hz (Outdoor unit)
530
580
1,8
25/30/36/40
25/30/36/40
285x825x213
10
47
48
48
930
980
2,3
28/34/38/42
28/34/38/41
298x1065x234
12
51
52
548x720x265
30
548x720x265
32
670x880x285
44
6,35 (1/4)
9,52 (3/8)
15
7
7,5
15
10
6,35 (1/4)
9,52 (3/8)
15
7
7,5
15
10
6,35 (1/4)
12,7 (1/2)
30
15
10
25
20
SAP-KRV246EH
SAP-CRV246EH
Cooling
Heating
7,1 (1,2-8,0)
8,5 (1,3-9,5)
2355 (280-2845)
2490 (290-3150)
3,01
3,41
B
B
1177,5
10,5 (1,2-13,6)
11,0 (1,3-15,1)
1130
1180
2,3
30/41/44/47
30/40/43/46
298x1065x234
12
55
56
740x900x320
59
Installation data
Pipe diameter
Maximum piping length
Maximum elevation difference
Charge less piping length
Amount of additional refrigerant
Recommended fuse/circuit breaker capacity
Narrow
Wide
mm(in.)
mm(in.)
m
m
m
g/m
A
Outdoor
43°C DB
19°C DB
(96 & 126)
-15°C DB
(186 & 246)
14
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Indoor
Outdoor
6,35 (1/4)
15,88 (5/8)
30
15
10
25
20
Specifications subject to change without notice.
Indoor
32°C DB
18°C WB
27°C DB
19°C DB
-15°C WB
16°C DB
(except model 246)
Energy class
A
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
R410A
15
XRV type
4 way cassette
Room Air Conditioners
SAP-XRV...EH
SAP-CRV...EH
The XRV type DC inverter-driven cassette is ultra
compact to fit perfectly into European standard
600 x 600mm ceiling grids and is ideal for small
­commercial and retrofit projects.
SAP-CRV...EH
• Light and compact design making it quick and easy
to install
• DC inverter technology for precise temperature control
• Auto restart after power failure and auto changeover
• A
uto air sweep control provides uniform air flow in
the room
• Powerful start function for rapid cooling/heating
• A
utomatic cooling/ heating control maintains the desired
temperature
• Cooling and heating down to -15°C (Model 186)
• C
ondensate elimination pump with pressure head up
to 250mm
• M
ultifunctional remote control with integrated temperature
sensor
Indoor unit
Outdoor unit
System performance
Capacity
Power input
EER/COP
Energy class
Annual energy consumption
Running current
Power supply
Indoor unit specifications
Air circulation
Moisture removal
Sound pressure level
Dimensions Unit
Dimensions Panel
Net weight Unit
Net weight Panel
• Clock with ON/OFF program timer
Outdoor unit specifications
Sound pressure level
Dimensions
Net weight
• Washable filter avoids formation of mould and bacteria
Installation data
• Removable and washable panel with a modern design
Pipe diameter
• N
ight Set back/economy mode function ensuring energysaving in cooling and heating
Remote
Maximum piping length
Maximum elevation difference
Charge less piping length
Amount of additional refrigerant
Recommended fuse/circuit breaker capacity
SAP-XRV...EH
PNR-XMRV93EHAA
SAP-XRV96EH
SAP-CRV96EH
kW
W
kWh
A
V,ph,Hz
(H)
(H)
(L/M/H)
(H×W×D)
(H×W×D)
m3/h
Litres/h
dB(A)
mm
mm
kg
kg
(H)
(H×W×D)
dB(A)
mm
kg
Narrow
Wide
SAP-XRV126EH
SAP-CRV126EH
Cooling
2,6 (0,9-3,2)
810 (250-1180)
3,21
A
405
4,0 (1,2-6,0)
Heating
3,5 (0,9-4,8)
930 (250-1545)
3,76
A
4,5 (1,2-6,6)
700
1,5
37/40/44
700
37/40/44
Cooling
Heating
3,3 (0,9-3,8)
4,5 (0,9-5,8)
980 (250-1325)
1240 (250-1720)
3,37
3,63
A
A
490
4,6 (1,2-6,3)
5,7 (1,2-7,3)
220-240V Single-Phase 50Hz (Outdoor unit)
700
1,8
37/40/44
296x575x575
41x730x730
16,5
2,5
47
mm(in.)
mm(in.)
m
m
m
g/m
A
Outdoor
43°C DB
19°C DB
(96 & 126)
-15°C DB
700
37/40/44
Cooling
5,15 (1,20-5,30)
1600 (250-1830)
3,22
A
800
7,2 (1,2-8,6)
Heating
6,0 (1,3-6,4)
1650 (270-1960)
3,64
A
7,4 (1,3-9,2)
790
2,0
37/40/45
790
37/40/45
296x575x575
41x730x730
16,5
2,5
47
48
548x720x265
32
6,35 (1/4)
9,52 (3/8)
15
7
7,5
15
10
6,35 (1/4)
9,52 (3/8)
15
7
7,5
15
10
Outdoor
296x575x575
41x730x730
18,0
2,5
48
548x720x265
30
Indoor
SAP-XRV186EH
SAP-CRV186EH
51
52
670x880x285
44
6,35 (1/4)
12,7 (1/2)
30
7
10
25
20
Specifications subject to change without notice.
Indoor
32°C DB
18°C WB
27°C DB
19°C DB
-15°C WB
16°C DB
Energy class
A
R410A
(186)
16
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
17
F/FT type
floor & ceiling mounted
Room Air Conditioners
SAP-FRV96EH
SAP-FTRV...EH
SAP-CRV...EH
The floor & ceiling mounted units are flexible
and e
­ ffective alternative to wall-mounted units.
SAP-CRV...EH
• DC inverter technology for precise temperature control
• Air flow optimised for heating
• Powerful and lightweight compact design
• Auto restart after power failure and auto changeover
• Automatic air flow control
• A
utomatic cooling/ heating control maintains the desired
temperature
• Cooling and heating down to -15°C (Models 186 and 246)
• M
ultifunctional remote control with integrated temperature
sensor
• Clock with ON/OFF program timer
• Washable filter avoids formation of mould and bacteria
• Washable front panel
• N
ight Set back/economy mode function ensuring energysaving in cooling and heating
Remote
Indoor unit
Outdoor unit
System performance
Capacity
Power input
EER/COP
Energy class
Annual energy consumption
Running current
Power supply
SAP-FRV96EH
SAP-FTRV...EH, ceiling mounted
SAP-FRV96EH
SAP-CRV96EH
kW
W
kWh
A
Indoor unit specifications
Air circulation
Moisture removal
Sound pressure level
Dimensions
Net weight
(H)
(H)
(L/M/H)
(H×W×D)
m3/h
Litres/h
dB(A)
mm
kg
Outdoor unit specifications
Sound pressure level
Dimensions
Net weight
(H)
(H×W×D)
dB(A)
mm
kg
Cooling
2,55 (0,9-3,2)
700 (250-1140)
3,64
A
350
3,2 (1,2-5,8)
Heating
3,2 (0,9-4,5)
930 (250-1510)
3,44
B
4,5 (1,2-6,5)
SAP-FTRV126EH
SAP-FTRV186EH
SAP-CRV126EH
SAP-CRV186EH
Cooling
Heating
Cooling
Heating
3,35 (0,9-3,5)
4,3 (0,9-5,8)
5,15 (1,2-5,3)
6,0 (1,3-6,4)
1090 (250-1330)
1180 (250-1720)
1550 (250-1840)
1710 (270-1970)
3,07
3,64
3,32
3,51
B
A
A
B
545
775
5,1 (1,2-6,4)
5,5 (1,2-7,3)
7,0 (1,2-8,6)
7,8 (1,3-9,2)
220-240V Single-Phase 50Hz (Outdoor unit)
425
1,5
700
-
1,8
34/40/43
700x560x200
18,0
47
SAP-FTRV...EH, floor mounted
720
-
2,0
38/43/47
680x900x190
23,5
47
48
SAP-FTRV246EH
SAP-CRV246EH
Cooling
Heating
6,15 (1,2-6,9)
7,2 (1,3-8,0)
1900 (280-2865)
2340 (290-3170)
3,24
3,08
A
D
950
8,6 (1,2-13,7)
10,6 (1,3-15,2)
900
-
2,0
39/44/48
680x900x190
23,5
48
51
52
548x720x265
30
548x720x265
32
670x880x285
44
6,35 (1/4)
9,52 (3/8)
15
7
7,5
15
10
6,35 (1/4)
9,52 (3/8)
20
7
7,5
25
10
6,35 (1/4)
12,7 (1/2)
30
7
7,5
25
20
44/47/50
680x900x190
23,5
55
56
740x900x320
59
Installation data
Pipe diameter
Maximum piping length
Maximum elevation difference
Charge less piping length
Amount of additional refrigerant
Recommended fuse/circuit breaker capacity
Narrow
Wide
mm(in.)
mm(in.)
m
m
m
g/m
A
6,35 (1/4)
15,88 (5/8)
30
7
7,5
25
20
Specifications subject to change without notice.
floor or ceiling application
Outdoor
43°C DB
19°C DB
(96 & 126)
-15°C DB
Indoor
Outdoor
Indoor
32°C DB
18°C WB
27°C DB
19°C DB
-15°C WB
16°C DB
R410A
(186 & 246)
18
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
19
URV type
concealed duct
Room Air Conditioners
SAP-URV...EH
SAP-CRV...EH
Top performance ducted units providing flexible airconditioning together with low noise levels. Ideal for
flexible, concealed air conditioning applications.
SAP-CRV...EH
• The integrated unit has a height of 266mm to fit standard
architectural scheme
• U
sing the supplementary cable it is possible to increase the
static pressure to satisfy any duct-related requirement
• DC inverter technology for precise temperature control
• Light and compact design
• Auto restart after power failure and auto changeover
• Powerful start function for rapid cooling/heating
• A
utomatic cooling/ heating control maintains the desired
temperature
• E xternal electrical panel for rapid cable attachments and
simple maintenance
• Cooling and heating down to -15°C (models 186 and 246)
• C
ondensate elimination pump with pressure head up
to 250mm
• M
ultifunctional remote control with integrated temperature
sensor
• Clock with ON/OFF program timer
• T he included air filter is easily accessible from the lower
part of the unit
Remote
Indoor unit
Outdoor unit
System performance
Capacity
Power input
EER/COP
Energy class
Annual energy consumption
Running current
Power supply
SAP-URV...EH
Plenum
SAP-URV96EH
SAP-CRV96EH
kW
W
kWh
A
V,ph,Hz
Indoor unit specifications
Air circulation
External static pressure std. (booster)
Moisture removal
Sound pressure level
Dimensions
Net weight
(H)
(H)
(H)
(L/M/H)
(H×W×D)
m3/h
Pa
Litres/h
dB(A)
mm
kg
Outdoor unit specifications
Sound pressure level
Dimensions
Net weight
(H)
(H×W×D)
dB(A)
mm
kg
Cooling
2,6 (0,9-3,2)
750 (250-1230)
3,47
A
375,0
3,5
Heating
3,5 (0,9-3,8)
920 (250-1590)
3,80
A
4,2
620
620
Plenum
SAP-URV126EH
SAP-URV186EH
SAP-CRV126EH
SAP-CRV186EH
Cooling
Heating
Cooling
Heating
3,5 (0,9-3,8)
4,5 (0,9-5,8)
5,4 (1,2-5,5)
6,0 (1,3-6,4)
1010 (250-1375)
1245 (250-1765)
1650 (250-1830)
1600 (270-1960)
3,47
3,61
3,27
3,75
A
A
A
A
505
825
4,6
5,7
7,4
7,3
220-240V Single-Phase 50Hz (Outdoor unit)
620
620
865
865
SAP-URV246EH
SAP-CRV246EH
Cooling
Heating
7,15 (1,2-7,5)
8,5 (1,3-9,5)
2370 (280-2850)
2640 (290-3160)
3,02
3,22
B
C
1185
10,9
12
985
985
49 (69)
1,5
40/43/45
40/43/45
1,8
40/43/45
266x852x571
30
47
40/43/45
266x852x571
30
47
48
48
2,0
33/38/45
33/38/45
266x1058x571
35,0
51
52
548x720x265
30,0
548x720x265
32,0
670x880x285
44,0
6,35 (1/4)
9,52 (3/8)
15
7
7,5
15
10
6,35 (1/4)
9,52 (3/8)
15
7
7,5
15
10
6,35 (1/4)
12,7 (1/2)
20
7
7,5
25
20
2,5
37/40/48
37/40/48
266x1058x571
35,0
55
56
740x900x320
59,0
Installation data
Pipe diameter
Maximum piping length
Maximum elevation difference
Charge less piping length
Amount of additional refrigerant
Recommended fuse / circuit breaker capacity
Narrow
Wide
mm(in.)
mm(in.)
m
m
m
g/m
A
6,35 (1/4)
15,88 (5/8)
30
7
7,5
25
20
Specifications subject to change without notice.
• N
ight Set back/economy mode function ensuring energysaving in cooling and heating
Outdoor
43°C DB
19°C DB
(96 & 126)
-15°C DB
Indoor
Outdoor
Indoor
32°C DB
18°C WB
27°C DB
19°C DB
-15°C WB
16°C DB
(except model 246)
Energy class
A
R410A
(186 & 246)
20
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
21
KR type
wall mounted
Room Air Conditioners
SAP-KR...EHAX
SAP-CR...EHAX
SANYO’s new 7 Series KR type unit is
stylish, with a sleek and discrete design
that fits perfectly in any interior.
SAP-CR...EHAX
• Lightweight and compact
Remote
The High power key funktion allows a much faster achievement
of the desired temperature compared to conventional room
airconditioners operations.
• Improved efficiency
• LED sterilisation function
• High power function
High power function
• Cold draft prevention in heating mode
Room
temperature
Conventional room
airconditioniners operation
• Built‑in temperature sensor remote controller
Requested
temperature
• Economy mode (night set back)
Time
Double layer filter
SAP-KR...EHAX
Indoor unit
Outdoor unit
System performance
Capacity
Power input
EER/COP
Energy class
Annual energy consumption
Running current
Power supply
SAP-KR97EHAX
SAP-CR97EHAX
kW
W
kWh
A
V,ph,Hz
Indoor unit specifications
Air circulation
Moisture removal
Sound pressure level
Dimensions
Net weight
(H)
(H)
(Qt/L/M/H)
(H×W×D)
Outdoor unit specifications
Sound pressure level
Dimensions
Net weight
(H)
(H×W×D)
m3/h
Litres/h
dB(A)
mm
kg
dB(A)
mm
kg
Cooling
2,8
870
3,22
A
435
3,9
SAP-KR127EHAX
SAP-CR127EHAX
Heating
Cooling
Heating
2,8
3,3
3,6
775
1025
995
3,61
3,22
3,62
A
A
A
512,5
3,5
4,6
4,5
220-240V Single-Phase 50Hz (Outdoor unit)
600
1,5
25/31/34/39
600
25/31/34/39
250x799x205
7,5
48
48
510x660x240
27,0
10
640
2,3
26/32/35/40
26/32/35/40
250x799x205
7,5
50
50
598x660x240
33,0
Installation data
Narrow
Wide
Pipe diameter
mm(in.)
mm(in.)
m
m
m
g/m
A
Maximum piping length
Maximum elevation difference
Charge less piping length
Amount of additional refrigerant
Recommended fuse/circuit breaker capacity
Outdoor
22
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Indoor
Outdoor
6,35 (1/4)
9,52 (3/8)
15
7
7,5
15
10
6,35 (1/4)
9,52 (3/8)
15
7
7,5
15
10
Specifications subject to change without notice.
Indoor
43°C DB
32°C DB
18°C WB
27°C DB
19°C DB
19°C DB
-9°C WB
16°C DB
Energy class
A
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
R410A
23
KR type (4 Series)
wall mounted
Room Air Conditioners
SAP-KR...EHA
SAP-CR...EHA/DHA
SANYO’s online fixed-speed range provides
outstanding performance and offers an economic
alternative to inverter technology.
SAP-CR...EHA/DHA
• Lightweight and compact design for easy installation
• Auto restart after power failure
• M
ultifunctional wireless remote control with built-in
temperature sensor with ON/OFF program timer
• Cold draft prevention
• Automatic cooling and heating changeover
• Ion generator refreshes your room with negative ions
(184 & 224)
• Night set back/economy mode function ensures gentle
and energy-saving cooling and heating
Remote
Indoor unit
Outdoor unit
System performance
Capacity
Power input
EER/COP
Energy class
Annual energy consumption
Running current 1ph/3ph
Power supply
SAP-KR...EHA
kW
W
kWh
A
V,ph,Hz
Indoor unit specifications
Air circulation
Moisture removal
Sound pressure level
Dimensions
Net weight
(H)
(H)
(Qt/L/M/H)
(H×W×D)
Outdoor unit specifications
Sound pressure level
Dimensions
Net weight
(H)
(H×W×D)
m3/h
Litres/h
dB(A)
mm
kg
dB(A)
mm
kg
SAP-KR74EHA
SAP-CR74EHA
Cooling
Heating
2,2
2,5
685
690
3,21
3,62
A
A
342,5
3,1
3,1
SAP-KR94EHA
SAP-KR124EHA
SAP-CR94EHA
SAP-CR124EHA
Cooling
Heating
Cooling
Heating
2,65
3,0
3,5
4,0
825
830
1090
1105
3,21
3,61
3,21
3,62
A
A
A
A
412,5
545
3,7
3,8
4,9
5,0
220-240V Single-Phase 50Hz (Outdoor unit)
430
450
1,3
25/28/32/36
24/27/31/35
285x825x189
10
46
47
480
500
1,8
25/28/33/38
24/27/32/37
285x825x189
10
47
48
500
530
2
25/28/34/41
24/27/33/40
285x825x189
10
49
SAP-KR184EHA
SAP-KR224EHA
SAP-CR184EHA/DHA
SAP-CR224EHA/DHA
Cooling
Heating
Cooling
Heating
5,15
5,70
6,4
7,2
1600
1580
2275
2240
3,22
3,61
2,81
3,21
A
A
C
C
800
1137,5
7,1/3,2
7,0/3,2
10,0
9,8
380-415 V, 3 ph, 50 Hz (Outdoor unit)
890
890
2,3
32/35/39/42
32/34/38/41
298x1065x218
12
50
55
56
548x720x265
29,0
548x720x265
35,0
565x790x285
37,0
670x880x285
48,0
6,35 (1/4)
9,52 (3/8)
15
7
7,5
15
10
6,35 (1/4)
9,52 (3/8)
15
7
7,5
15
10
6,35 (1/4)
9,52 (3/8)
15
7
7,5
15
10
6,35 (1/4)
12,7(1/2)
30
7
7,5
25
15
980
980
3,3
32/37/41/45
32/36/40/44
298x1065x218
12
57
58
670x880x285
56,0
Installation data
Pipe diameter
Maximum piping length
Maximum elevation difference
Charge less piping length
Amount of additional refrigerant
Recommended fuse/circuit breaker capacity 1ph/3ph
Narrow
Wide
mm(in.)
mm(in.)
m
m
m
g/m
A
Outdoor
24
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Indoor
Outdoor
6,35 (1/4)
15,88 (5/8)
30
7
10
25
10
Specifications subject to change without notice.
Indoor
43°C DB
32°C DB
18°C WB
27°C DB
19°C DB
19°C DB
-9°C WB
16°C DB
(except model 244)
Energy class
A
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
R410A
25
XR type
4 way cassette
Room Air Conditioners
SAP-XR...EH(A)
SAP-CR...EHA
The XR type cassette is designed to fit into a
standard 600 x 600mm ceiling grid and is ideal
for small commercial and retrofit applications.
SAP-CR....EHA
• Lightweight and compact design for easy installation
• Auto restart after power failure and auto changeover
• Cold draft prevention
• I nfrared remote control with 24 hour clock with ON/OFF
program timer
• M
ulti-directional airflow provides uniform airflow
throughout the room
• Built-in drain pump gives 250mm lift
• A
uto air sweep control provides uniform air flow in
the room
• The modern‑style panel can be removed and washed
• N
ight set back/economy mode function ensures gentle
and energy-saving cooling and heating
Remote
Indoor unit
Outdoor unit
System performance
Capacity
Power input
EER/COP
Energy class
Annual energy consumption
Running current
Power supply
Indoor unit specifications
Air circulation
Moisture removal
Sound pressure level
Dimensions Unit
Dimensions Panel
Net weight unit
Net weight panel
Outdoor unit specifications
Sound pressure level
Dimensions
Net weight
Installation data
Pipe diameter
Maximum piping length
Maximum elevation difference
Precharged piping length
Amount of additional refrigerant
Recommended fuse/circuit breaker capacity
SAP-XR...EH(A)
SAP-XR94EHA
SAP-CR94EHA
Cooling
2,87
875
3,28
A
437,5
4,5
kW
W
kWh
A
V,ph,Hz
(H)
(H)
(Qt/L/M/H)
(H×W×D)
m3/h
Litres/h
dB(A)
mm
Narrow
Wide
dB(A)
mm
kg
47
mm(in.)
mm(in.)
m
m
m
g/m
A
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
700
37/40/43
700
1
37/40/43
296x575x575
41x730x730
16,5
2,5
kg
kg
(H)
(H×W×D)
SAP-XR124EHA
SAP-CR124EHA
Heating
Cooling
3,1
3,65
775
1075
4,0
3,4
A
A
537,5
4,5
5,2
220-240V Single-Phase 50Hz (Indoor unit)
700
0,5
37/40/43
Outdoor
26
PNR-X99EHAA
Heating
4,52
1055
4,28
A
5,3
Cooling
Heating
5,0
6,0
1650
1650
3,03
3,64
B
A
825
7,0
7,0
220-240V, 1ph, 50Hz (Outdoor unit)
700
37/40/43
790
2,0
37/40/45
296x575x575
41x730x730
16,5
2,5
48
49
565x790x285
37,0
6,35 (1/4)
9,52 (3/8)
15
7
7,5
15
10
6,35 (1/4)
9,52 (3/8)
20
7
7,5
25
10
Outdoor
790
37/40/45
296x575x575
41x730x730
18
2,5
50
548x720x265
35,0
Indoor
SAP-XR184EH
SAP-CR184EHA
55
56
670x880x285
48,0
6,35 (1/4)
12,7(1/2)
30
7
7,5
25
20
Specifications subject to change without notice.
Indoor
43°C DB
32°C DB
18°C WB
27°C DB
19°C DB
19°C DB
-9°C WB
16°C DB
(except model 184)
Energy class
A
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
R410A
27
F/FT type
floor & ceiling mounted
Room Air Conditioners
SAP-FR94EHA
SAP-FTR...EH(A)
SAP-CR...EHA
SANYO’s constant speed FTR range of console
units can be mounted on the ceiling or the floor
to provide a flexible solution to difficult installation
situations.
SAP-CR...EHA
• Auto restart after power failure and auto changeover
• Cold draft prevention in heating mode
• Lightweight and compact designs
• I nfrared remote control with 24 hour clock with ON/OFF
program timer
• A
utomatic louvre control provides uniform airflow
throughout the room
• E asy to clean filter prevents mould or bacteria from
occurring
• N
ight set back/economy mode function ensures gentle
and energy-saving cooling
Indoor unit
Outdoor unit
System performance
Capacity
Power input
EER/COP
Energy class
Annual energy consumption
Running current 1ph
Power supply
SAP-FR94EHA
kWh
A
V,ph,Hz
400
400
1,0
34/40/43
34/40/43
700x560x200
18,0
720
720
2,0
39/44/48
39/44/48
680x900x190
23,5
(H)
(H)
(L/M/H)
(H×W×D)
m3/h
Litres/h
dB(A)
mm
kg
Outdoor unit specifications
Sound pressure level
Dimensions
Net weight
(H)
(H×W×D)
dB(A)
mm
kg
Maximum piping length
Maximum elevation difference
Precharched piping length
Amount of additional refrigerant
Recommended fuse/circuit breaker capacity
47
48
49
50
55
56
565x790x285
37,0
670x880x285
48,0
6,35 (1/4)
9,52 (3/8)
15
7
7,5
15
10
6,35 (1/4)
9,52 (3/8)
20
7
7,5
25
10
6,35 (1/4)
12,7(1/2)
30
7
7,5
25
20
mm(in.)
mm(in.)
m
m
m
g/m
A
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
700
700
1,3
38/43/47
38/43/47
680x900x190
23,5
548x720x265
35,0
Outdoor
28
SAP-FTR...EH(A), floor mounted
SAP-FTR184EH
SAP-FTR224EH
SAP-CR184EHA
SAP-CR224EHA
Cooling
Heating
Cooling
Heating
5,05
5,90
6,25
7,4
1650
1700
2300
2600
3,06
3,47
2,72
2,85
B
B
D
D
825
1150
7,0
7,2
9,9
11,2
220-240V, 1ph, 50Hz (Outdoor unit)
kW
W
Narrow
Wide
SAP-FTR...EH(A), ceiling mounted
SAP-FR94EHA
SAP-FTR124EHA
SAP-CR94EHA
SAP-CR124EHA
Cooling
Heating
Cooling
Heating
2,65
3,2
3,6
4,35
825
810
1055
1045
3,21
3,95
3,41
4,16
A
A
A
A
412,5
527,5
3,9
3,9
5,0
5,1
220-240V Single-Phase 50Hz (Indoor unit)
Indoor unit specifications
Air circulation
Moisture removal
Sound pressure level
Dimensions
Net weight
Installation data
Pipe diameter
Floor or ceiling application
Remote
Indoor
Outdoor
900
900
2,2
44/47/50
44/47/50
680x900x190
23,5
57
58
670x880x285
56,0
6,35 (1/4)
15,88 (5/8)
30
7
7,5
25
20
Specifications subject to change without notice.
Indoor
43°C DB
32°C DB
18°C WB
27°C DB
19°C DB
19°C DB
-9°C WB
16°C DB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
R410A
29
UR type
concealed duct
Room Air Conditioners
SAP-UR...EH
SAP-CR...EHA
The UR ducted unit is ideal for flexible, concealed
cooling and heating in all types or room air
conditioning applications.
SAP-CR...EHA
• Auto restart after power failure and auto change over
• Cold draft prevention
• Fresh air knockout
• I nfrared remote control with 24 hour clock with ON/OFF
program timer
• Built-in drain pump gives 250mm lift
• Booster cable available to increase static pressure
• Powerful start function for rapid cooling and heating
• E xternal electrical box allows ease of access for service
and maintenance
• N
ight set back and economy mode function ensures
energy-saving cooling and heating
Remote
Indoor unit
Outdoor unit
System performance
Capacity
Power input
EER/COP
Energy class
Annual energy consumption
Running current 1ph
Power supply
SAP-UR...EH
SAP-UR94EHA
SAP-CR94EHA
kW
W
kWh
A
V,ph,Hz
Indoor unit specifications
Air circulation
Moisture removal
External static pressure std. (booster)
Sound pressure level
Dimensions
Net weight
(H)
(H)
(H)
(L/M/H)
(H×W×D)
m3/h
Litres/h
Pa
dB(A)
mm
kg
Outdoor unit specifications
Sound pressure level
Dimensions
Net weight
(H)
(H×W×D)
dB(A)
mm
kg
Installation data
Pipe diameter
Maximum piping length
Maximum elevation difference
Precharched piping length
Amount of additional refrigerant
Recommended fuse / circuit breaker capacity
Plenum
Narrow
Wide
Cooling
2,65
880
3,49
A
440
4,1
600
0,8
600
-
600
1,5
600
-
40/43/45
40/43/45
40/43/45
40/43/45
266x852x571
30
47
mm(in.)
mm(in.)
m
m
m
g/m
A
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
SAP-UR184EH
SAP-UR224EH
SAP-CR184EHA
SAP-CR224EHA
Cooling
Heating
Cooling
Heating
5,20
6,15
6,7
7,4
1700
1750
2350
2450
3,06
3,51
2,85
3,02
B
B
C
D
850
1175
7,2
7,5
10,1
10,5
220-240V, 1ph, 50Hz (Outdoor unit)
865
2,0
865
-
985
2,2
985
-
49 (69)
Outdoor
30
SAP-UR124EHA
SAP-CR124EHA
Heating
Cooling
Heating
3,0
4,5
4,62
780
1130
1060
4,1
3,58
4,36
A
A
A
565
4,2
5,3
5,4
220-240V Single-Phase 50Hz (Indoor unit)
Plenum
266x852x571
30
48
49
50
33/38/45
33/38/45
266x1058x571
35
55
56
548x720x265
35,0
565x790x285
37,0
670x880x285
48,0
6,35 (1/4)
9,52 (3/8)
15
7
7,5
15
10
6,35 (1/4)
9,52 (3/8)
20
7
7,5
25
10
6,35 (1/4)
12,7(1/2)
30
7
7,5
25
20
Indoor
Outdoor
33/40/48
33/40/48
266x1058x571
35
57
58
670x880x285
56,0
6,35 (1/4)
15,88 (5/8)
30
7
7,5
25
20
Specifications subject to change without notice.
Indoor
43°C DB
32°C DB
18°C WB
27°C DB
19°C DB
19°C DB
-9°C WB
16°C DB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
R410A
31
Flexi Multi
Outdoor units
Room Air Conditioners
SAP-CMRV1426EH
SAP-CMRV1926EH
SAP-CMRV1936EH
SAP-CMRV2446EH
SAP-CMRV3146EH
SAP-FTRV...EH
SAP-CMRV....EH
Design guaranteed for an extremely efficient
and flexible operation.
• D
C inverter technology for precise temperature control and a
low start-up current
• T win rotary compressor: the dual rotors guarantee perfect
balancing ensuring functional reliability and efficiency. This
also contributes to increase comfort and accelerate cooling
and heating as well as ensuring an extremely quiet and
efficient operation.
• E nergy class A/A for the whole range, both in cooling and
heating modes
• O
perating range decreased to -15°C in heating mode and
-5°C in cooling mode
• T he volume of the external unit has been decreased by 9%,
solving the problem of limited space and does not encumber
the exterior
Remote
The flexible solution
• The SANYO Flexi Multi range of heat pump multi split
systems are the ideal, flexible solution for providing quiet
and efficient air conditioning to 2, 3 or 4 areas (new Flexi
Multi SAP-CMRV3656EH even up to 5 areas!) from a single
outdoor unit.
• 5 system capacities 4.0kW to 8.0kW
• 6 indoor model styles
• 2, 3 or 4 way multi split
• D
C inverter technology for precise temperature control and
low start current
• Provides heating or cooling as required
SAP-XRV...EH
SAP-URV...EH
SAP-K(M)RV...EH
SAP-KRV...EHDS
Heat-Pump Inverter
Outdoor units
Performance
Capacity kW
Power consumption W
EER/COP W/W
Energy class
Current draw A
Annual consumption (cooling) kW/h
Max. number of units N.
Sound pressure dB(A)
Noise level dB(A)
Pipe diameter - suction/discharge mm(in)
Maximum total pipe length m
Maximum pipe length per unit m
Max. elevation difference E.U - I.U m
Total pipe length - standard charge m
Dimensions (HxLxD) mm
Net weight kg
Power supply V,ph,Hz
SAP-CMRV1426EH
Cooling
Heating
2,0/4,0/5,0 2,2/4,5/5,5
925
925
4,32
4,86
A
A
4,10
4,10
462,5
2
47
48
61
62
2x6,4(1/4) 2x9,5(3/8)
30
20
15
30
569x790x285
42
230, 1+N, 50
SAP-FRV....EH
SAP-CMRV1926EH
Cooling
Heating
2,1/5,6/6,8 2,4/7,3/8,4
1695
1735
3,30
4,21
A
A
7,52
7,70
847,5
2
47
48
61
62
2x6,4(1/4) 2x9,5(3/8)
45
25
15
45
740x900x320
65
230, 1+N, 50
SAP-CMRV1936EH
SAP-CMRV2446EH
SAP-CMRV3146EH
Cooling
Heating
Cooling
Heating
Cooling
Heating
2,9/5,2/6,5 3,4/6,8/7,8 2,9/6,8/8,1 3,4/8,6/9,0 2,9/8,0/9,2 3,4/9,4/9,8
1530
1610
2000
2000
1730
2040
3,40
4,22
3,40
4,30
4,62
4,61
A
A
A
A
A
A
6,88
7,70
8,87
8,87
7,58
8,96
765
1000
865
3
4
4
47
48
49
51
47
48
61
62
63
65
61
62
3x6,4(1/4) 2x9,5(3/8)
3x6,4 (1/4) 3x9,5(3/8) 12,7 (1/2) 4x6,4 (1/4) 2x9,5(3/8) 2x12,7(1/2)
45
60
70
25
25
30
15
15
15
45
45*
45**
740x900x320
740x900x320
890x900x320
65
65
82
230, 1+N, 50
230, 1+N, 50
230, 1+N, 50
* For longer pipes, up to 60m add 20 g/m of refrigerant.
** For longer pipes, up to 70m add 20 g/m of refrigerant.
Reference conditions: Annual energy consumption = consumption for 500 hours at nominal load.
* For external temperatures < 7°C the heating capacity will be lower than the nominal capacity.
• N
on-stop heating by means of SANYO’s exclusive hot gas
by-pass system
Specifications subject to change without notice.
• Renewable and washable apatite ceramic filter
• P
hoto-catalytic LED sterilization function ensures excellent
performance in eliminating odours, germs and bacteria (only
wall-mounted units)
• N
ight Set back/Economy modes to guarantee quiet and
energy-efficient cooling and heating
• Programmable start-up and shut-off via 24 hour clock
Flexi Multi System Example
32
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Outdoor
Indoor
Outdoor
Indoor
43°C DB
32°C DB
18°C WB
27°C DB
-5°C DB
19°C DB
-15°C WB
16°C DB
Energy class
A
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
R410A
33
Flexi Multi
Room Air Conditioners
SAP-KRV...EHDS
SAP-K(M)RV...EH
SAP-XRV...EH
SAP-FTRV...EH
SAP-FRV...EH
SAP-URV...EH
SAP-KRV96EHDS
Indoor unit
Performance
Capacity
Air circulation
Moisture removal
Sound pressure level
Dimensions
Net weight
SAP-K(M)RV…EH
Indoor unit
Performance
Capacity
Air circulation
Moisture removal
Sound pressure level
Dimensions
Net weight
SAP-XRV…EH
Indoor unit
Performance
Capacity
Air circulation
Moisture removal
Sound pressure level
Dimensions unit
Dimensions panel
Net weight
SAP-FTRV…EH
SAP-FRV…EH
Indoor unit
Performance
Capacity
Air circulation
Moisture removal
Sound pressure level
Dimensions
Net weight
SAP-KRV...EHDS
SAP-KRV96EHDS
kW
m3/h
Litres/h
dB(A)
mm
kg
(H)
(H)
(Qt/L/M/H)
(H×W×D)
(H)
(H)
(Qt/L/M/H)
(H×W×D)
kW
m3/h
Litres/h
dB(A)
mm
kg
Cooling
0,9/2,65/3,6
480
1,6
22/28/35/41
SAP-XRV...EH
SAP-KRV126EHDS
Heating
0,9/3,6/4,9
500
22/28/35/41
Cooling
3,50
510
2,0
22/28/35/42
265x789x180
9,5
Heating
4,80
560
22/29/36/42
265x789x180
9,5
SAP-KMRV76EH
SAP-KMRV96EH
SAP-KMRV126EH
SAP-KRV186EH
SAP-KRV246EH
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
-/2,2/-/2,5/-/2,65/-/3,6/-/3,5//4,2/-/5,15/-/6,0/-/7,1/-/8,5/440
480
460
480
480
500
840
880
890
930
1,3
1,6
2,0
2,3
2,3
22/27/30/33 22/27/30/33 22/28/31/34 22/28/31/34 25/29/33/36 25/29/31/34 28/34/38/41 28/34/37/40 30/38/41/44 30/37/40/43
285x825x213
285x825x213
285x825x213
298x1065x234
298x1065x234
10
10
10
12
12
kW
m3/h
Litres/h
dB(A)
mm
(H)
(H)
(L/M/H)
(H×W×D)
kg
SAP-XRV96EH
Cooling
Heating
-/2,65/-/3,6/700
700
1,5
37/40/44
273x575x575
41x730x730
16,5
SAP-XRV126EH
Cooling
Heating
-/3,5//4,2/700
700
1,8
37/40/44
273x575x575
41x730x730
16,5
SAP-XRV186EH
Cooling
Heating
-/5,15/-/6,0/790
790
2,0
37/40/45
273x575x575
41x730x730
18
SAP-FTRV...EH
(H)
(H)
(L/M/H)
(H×W×D)
kW
m3/h
Litres/h
dB(A)
mm
kg
SAP-FRV96EH
Cooling
Heating
-/2,65/-/3,6/425
425
1,6
30/40/43
700x560x200
18
SAP-URV96EH
Cooling
Heating
-/2,65/-/3,6/620
620
1,5
49/69
40/43/45
266x852x571
30
SAP-FTRV126EH
Cooling
Heating
-/3,5//4,2/700
700
2,0
38/43/47
680x900x190
23,5
SAP-URV126EH
Cooling
Heating
-/3,5//4,2/620
620
1,8
49/69
40/43/45
266x852x571
30
SAP-FTRV186EH
Cooling
Heating
-/5,15/-/6,0/720
720
2,8
41/45/49
680x900x190
23,5
SAP-FTRV246EH
Cooling
Heating
-/7,1/-/8,5/900
900
3,4
42/46/50
680x900x190
23,5
SAP-URV186EH
Cooling
Heating
-/5,15/-/6,0/865
865
2,0
49/69
33/38/45
266x1058x571
30
SAP-URV246EH
Cooling
Heating
-/7,1/-/8,5/985
985
2,5
49/69
37/40/48
266x1058x571
35
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
SAP-FRV...EH
SAP-URV...EH
SAP-CMRV1426EH
“Indoor unit combination SAP-K(M)RV..6EH”
Rated capacity (kW)
Cooling/Heating : 4.0/4.5
Cooling
Capacity (Min.-Max.) (kW)
Room B
Total
Room A
7
9
12
7+7
7+9
7 + 12
9+9
9 + 12
1 room
2 rooms
2,20
2,65
3,50
1,80
1,68
1,51
2,00
1,72
1,80
2,02
2,39
2,00
2,28
2,2
2,65
3,5
3,6
3,7
3,9
4,0
4,0
Heating
Capacity (Min.-Max.) (kW)
Room B
Total
Room A
(1,2-2,6)
(1,2-3,2)
(1,3-3,6)
(2,0-4,5)
(2,0-4,8)
(2,0-4,9)
(2,0-5,0)
(2,1-5,0)
2,50
3,60
4,20
2,10
1,72
1,64
2,25
2,08
2,10
2,48
2,76
2,25
2,42
2,5
3,6
4,2
4,2
4,2
4,4
4,5
4,5
(1,4-3,5)
(1,4-4,0)
(1,5-4,2)
(2,0-5,0)
(2,0-5,0)
(2,2-5,3)
(2,2-5,5)
(2,4-5,5)
The table lists the wall-mounted type of indor units as representative models. For details on the connection of indoor units other than the wall mounted type, refer to the technical data.
SAP-CMRV1926EH
“Indoor unit combination SAP-K(M)RV..6EH”
Cooling
Capacity (Min.-Max.) (kW)
Room A
Room B
Total
Rated capacity (kW)
Cooling/Heating : 5.6/7.3
7
9
12
18
7+7
7+9
7 + 12
7 + 18
9+9
9 + 12
9 + 18
12 + 12
12 + 18
1 room
2 rooms
2,20
2,65
3,50
5,15
2,20
2,20
1,97
1,65
2,50
2,24
1,90
2,70
2,27
2,20
2,65
3,13
3,85
2,50
2,96
3,70
2,70
3,33
2,2
2,65
3,5
5,15
4,4
4,85
5,1
5,5
5,0
5,2
5,6
5,4
5,6
Heating
Capacity (Min.-Max.) (kW)
Room A
Room B
Total
(1,4-2,6)
(1,4-3,2)
(1,5-3,6)
(1,6-5,8)
(2,0-5,1)
(2,0-5,8)
(2,0-6,7)
(2,1-6,8)
(2,0-6,3)
(2,0-6,8)
(2,1-6,8)
(2,0-6,8)
(2,1-6,8)
2,50
3,60
4,20
6,00
2,50
2,50
2,35
2,03
3,23
3,07
2,74
3,45
3,01
2,50
3,60
3,95
4,87
3,23
3,58
4,56
3,45
4,29
2,5
3,6
4,2
6,0
5,0
6,1
6,3
6,9
6,45
6,65
7,3
6,9
7,3
(1,8-4,3)
(1,8-4,7)
(1,9-5,1)
(2,0-7,8)
(2,0-6,4)
(2,1-7,5)
(2,1-8,3)
(2,4-8,4)
(2,3-8,4)
(2,3-8,4)
(2,4-8,4)
(2,3-8,4)
(2,4-8,4)
SAP-CMRV1936EH
“Indoor unit combination SAP-K(M)RV..6EH”
Rated capacity (kW)
Cooling/Heating : 5.6/7.3
2 rooms
3 rooms
Outdoor
Room A
7
9
12
18
7+7
7+9
7 + 12
7 + 18
9+9
9 + 12
9 + 18
12 + 12
12 + 18
7+7+7
7+7+9
7 + 7 + 12
7 + 7 + 18
7+9+9
7 + 9 + 12
7 + 9 + 18
7 + 12 + 12
9+9+9
9 + 9 + 12
9 + 12 + 12
12 + 12 + 12
1 room
SAP-URV…EH
Indoor unit
Performance
Capacity
kW
Air circulation
(H)
m3/h
Litres/h
Moisture removal
(H)
External static pressure (std/booster)
Pa
Sound pressure level
(L/M/H)
dB(A)
(H×W×D)
mm
Dimensions
Net weight
kg
All Specifications subject to change without notice.
34
SAP-K(M)RV...EH
Indoor
Outdoor
2,20
2,65
3,50
5,15
2,20
2,20
1,97
1,65
2,50
2,24
1,90
2,70
2,27
1,77
1,69
1,56
1,29
1,63
1,48
1,23
1,34
1,87
1,69
1,54
1,87
Indoor
43°C DB
32°C DB
18°C WB
27°C DB
-5°C DB
19°C DB
-15°C WB
16°C DB
Cooling
Capacity (Min.-Max.) (kW)
Room B Room C
Total
2,20
2,65
3,13
3,85
2,50
2,96
3,70
2,70
3,33
1,77
1,69
1,56
1,29
1,96
1,78
1,48
2,13
1,87
1,69
2,03
1,87
Room A
Heating
Capacity (Min.-Max.) (kW)
Room B Room C
Total
1,77
2,03
2,48
3,02
1,96
2,35
2,88
2,13
1,87
2,23
2,03
1,87
2,2
(1,4-2,6)
2,50
2,5
(1,8-4,3)
2,65
(1,4-3,2)
3,60
3,6
(1,8-4,7)
3,5
(1,5-3,6)
4,20
4,2
(1,9-5,1)
5,15
(1,6-5,8)
6,00
6,0
(2,0-7,8)
4,4
(2,0-5,1)
2,50
2,50
5,0
(2,0-6,4)
4,85
(2,0-5,8)
2,50
3,60
6,1
(2,1-7,5)
5,1
(2,0-6,7)
2,35
3,95
6,3
(2,1-8,3)
5,5
(2,1-6,8)
2,03
4,87
6,9
(2,4-8,4)
5,0
(2,0-6,3)
3,23
3,23
6,45
(2,3-8,4)
5,2
(2,0-6,8)
3,07
3,58
6,65
(2,3-8,4)
5,6
(2,1-6,8)
2,74
4,56
7,3
(2,4-8,4)
5,4
(2,0-6,8)
3,45
3,45
6,9
(2,3-8,4)
5,6
(2,1-6,8)
3,01
4,29
7,3
(2,4-8,4)
5,3
(2,5-6,8)
2,18
2,18
2,18
6,55
(2,7-8,4)
5,4
(2,9-6,8)
2,02
2,02
2,91
6,95
(3,0-8,4)
5,6
(2,9-6,8)
1,94
1,94
3,26
7,15
(3,2-8,4)
5,6
(2,9-6,8)
1,66
1,66
3,98
7,3
(3,4-8,4)
5,55
(2,9-6,8)
1,88
2,71
2,71
7,3
(3,4-8,4)
5,6
(2,9-6,8)
1,77
2,55
2,98
7,3
(3,4-8,4)
5,6
(2,9-6,8)
1,51
2,17
3,62
7,3
(3,4-8,4)
5,6
(2,9-6,8)
1,67
2,81
2,81
7,3
(3,4-8,4)
5,6
(2,9-6,8)
2,43
2,43
2,43
7,3
(3,4-8,4)
5,6
(2,9-6,8)
2,31
2,31
2,69
7,3
(3,4-8,4)
5,6
(2,9-6,8)
2,19
2,56
2,56
7,3
(3,4-8,4)
5,6
(2,9-6,8)
2,43
2,43
2,43
7,3
(3,4-8,4)
The table lists the wall-mounted type of indoor units as representative models.
For details on the connection of indoor units other than the wall mounted type, refer to the technical data.
All Specifications subject to change without notice.
Energy class
A
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
R410A
35
Flexi Multi Indoor Unit Capacities
(continued)
Room Air Conditioners
SAP-CMRV3146EH
SAP-CMRV2446EH
“Indoor unit combination SAP-K(M)RV..6EH”
Rated capacity (kW)
Cooling/Heating : 6.8/8.6
1 room
2 rooms
3 rooms
4 rooms
7
9
12
18
24
7+7
7+9
7 + 12
7 + 18
7 + 24
9+9
9 + 12
9 + 18
9 + 24
12 + 12
12 + 18
12 + 24
18 + 18
7+7+7
7+7+9
7 + 7 + 12
7 + 7 + 18
7+9+9
7 + 9 + 12
7 + 9 + 18
7 + 12 + 12
7 + 12 + 18
9+9+9
9 + 9 + 12
9 + 9 + 18
9 + 12 + 12
9 + 12 + 18
12 + 12 + 12
12 + 12 + 18
7+7+7+7
7+7+7+9
7 + 7 + 7 + 12
7 + 7 + 7 + 18
7+7+9+9
7 + 7 + 9 + 12
7 + 7 + 9 + 18
7 + 7 + 12 + 12
7 + 7 + 12 + 18
7+9+9+9
7 + 9 + 9 + 12
7 + 9 + 9 + 18
7 + 9 + 12 + 12
7 + 12 + 12 + 12
9+9+9+9
9 + 9 + 9 + 12
9 + 9 + 9 + 18
9 + 9 + 12 + 12
Cooling
Heating
Capacity (Min.-Max.) (kW)
Capacity (Min.-Max.) (kW)
Room A Room B Room C Room D
Total
Room A Room B Room C Room D
Total
2,20
2,2 (1,4-2,6) 2,50
2,5 (1,8-4,3)
2,65
2,65 (1,4-3,2) 3,60
3,6 (1,8-4,7)
3,50
3,5 (1,5-3,6) 4,20
4,2 (1,9-5,1)
5,15
5,15 (1,6-5,8) 6,00
6,0 (2,0-7,8)
6,80
6,8 (1,6-6,8) 8,00
8,0 (2,0-8,0)
2,20
2,20
4,4 (2,0-5,1) 2,50
2,50
5,0 (2,0-6,4)
2,20
2,65
4,85 (2,0-5,8) 2,50
3,60
6,1 (2,1-7,5)
2,20
3,50
5,7 (2,0-6,7) 2,50
4,20
6,7 (2,1-8,3)
1,95
4,55
6,5 (2,1-7,7) 2,38
5,72
8,1 (2,4-9,0)
1,57
5,08
6,65 (2,1-7,9) 2,01
6,44
8,45 (2,4-9,0)
2,65
2,65
5,3 (2,0-6,3) 3,60
3,60
7,2 (2,3-8,5)
2,54
3,36
5,9 (2,0-6,8) 3,51
4,09
7,6 (2,3-8,5)
2,28
4,42
6,7 (2,1-7,9) 3,08
5,13
8,2 (2,4-9,0)
1,85
4,95
6,8 (2,1-7,9) 2,64
5,86
8,5 (2,4-9,0)
3,23
3,23
6,45 (2,0-7,9) 4,00
4,00
8,0 (2,3-8,5)
2,69
3,96
6,65 (2,1-7,9) 3,42
4,88
8,3 (2,4-9,0)
2,25
4,55
6,8 (2,1-7,9) 2,96
5,64
8,6 (2,4-9,0)
3,40
3,40
6,8 (2,1-7,9) 4,28
4,28
8,55 (2,4-9,0)
2,17
2,17
2,17
6,5 (2,5-7,7) 2,50
2,50
2,50
7,5 (2,7-8,5)
2,06
2,06
2,48
6,6 (2,9-7,9) 2,33
2,33
3,35
8,0 (3,0-9,0)
1,88
1,88
2,99
6,75 (2,9-7,9) 2,26
2,26
3,79
8,3 (3,2-9,0)
1,57
1,57
3,67
6,8 (2,9-7,9) 1,95
1,95
4,69
8,6 (3,4-9,0)
1,97
2,37
2,37
6,7 (2,9-7,9) 2,16
3,12
3,12
8,4 (3,4-9,0)
1,79
2,16
2,85
6,8 (2,9-7,9) 2,06
2,97
3,47
8,5 (3,4-9,0)
1,50
1,80
3,50
6,8 (2,9-7,9) 1,78
2,56
4,26
8,6 (3,4-9,0)
1,63
2,59
2,59
6,8 (2,9-7,9) 1,97
3,31
3,31
8,6 (3,4-9,0)
1,38
2,19
3,23
6,8 (2,9-7,9) 1,69
2,84
4,06
8,6 (3,4-9,0)
2,27
2,27
2,27
6,8 (2,9-7,9) 2,87
2,87
2,87
8,6 (3,4-9,0)
2,05
2,05
2,70
6,8 (2,9-7,9) 2,72
2,72
3,17
8,6 (3,4-9,0)
1,72
1,72
3,35
6,8 (2,9-7,9) 2,35
2,35
3,91
8,6 (3,4-9,0)
1,87
2,47
2,47
6,8 (2,9-7,9) 2,58
3,01
3,01
8,6 (3,4-9,0)
1,59
2,11
3,10
6,8 (2,9-7,9) 2,24
2,62
3,74
8,6 (3,4-9,0)
2,27
2,27
2,27
6,8 (2,9-7,9) 2,87
2,87
2,87
8,6 (3,4-9,0)
1,96
1,96
2,88
6,8 (2,9-7,9) 2,51
2,51
3,58
8,6 (3,4-9,0)
1,70
1,70
1,70
6,8 (2,9-8,1) 2,15
2,15
2,15
2,15
8,6 (3,4-9,0)
1,70
1,62
1,62
1,62
1,95
6,8 (2,9-8,1) 1,94
1,94
1,94
2,79
8,6 (3,4-9,0)
1,48
1,48
1,48
2,36
6,8 (2,9-8,1) 1,84
1,84
1,84
3,09
8,6 (3,4-9,0)
1,27
1,27
1,27
2,98
6,8 (2,9-8,1) 1,59
1,59
1,59
3,82
8,6 (3,4-9,0)
1,54
1,54
1,86
1,86
6,8 (2,9-8,1) 1,76
1,76
2,54
2,54
8,6 (3,4-9,0)
1,42
1,42
1,71
2,26
6,8 (2,9-8,1) 1,68
1,68
2,42
2,82
8,6 (3,4-9,0)
1,23
1,23
1,48
2,87
6,8 (2,9-8,1) 1,47
1,47
2,12
3,53
8,6 (3,4-9,0)
1,31
1,31
2,09
2,09
6,8 (2,9-8,1) 1,60
1,60
2,70
2,70
8,6 (3,4-9,0)
1,15
1,15
1,82
2,68
6,8 (2,9-8,1) 1,41
1,41
2,38
3,39
8,6 (3,4-9,0)
1,47
1,78
1,78
1,78
6,8 (2,9-8,1) 1,62
2,33
2,33
2,33
8,6 (3,4-9,0)
1,36
1,64
1,64
2,16
6,8 (2,9-8,1) 1,55
2,23
2,23
2,60
8,6 (3,4-9,0)
1,18
1,42
1,42
2,77
6,8 (2,9-8,1) 1,37
1,97
1,97
3,29
8,6 (3,4-9,0)
1,26
1,52
2,01
2,01
6,8 (2,9-8,1) 1,48
2,14
2,49
2,49
8,6 (3,4-9,0)
1,18
1,87
1,87
1,87
6,8 (2,9-8,1) 1,42
2,39
2,39
2,39
8,6 (3,4-9,0)
1,70
1,70
1,70
1,70
6,8 (2,9-8,1) 2,15
2,15
2,15
2,15
8,6 (3,4-9,0)
1,57
1,57
1,57
2,08
6,8 (2,9-8,1) 2,06
2,06
2,06
2,41
8,6 (3,4-9,0)
1,38
1,38
1,38
2,67
6,8 (2,9-8,1) 1,84
1,84
1,84
3,07
8,6 (3,4-9,0)
1,47
1,47
1,93
1,93
6,8 (2,9-8,1) 1,98
1,98
2,32
2,32
8,6 (3,4-9,0)
The table lists the wall-mounted type of indor units as representative models. For details on the connection of indoor units other than the wall mounted type, refer to the technical data.
Specifications subject to change without notice. .
R410A
36
Energy class
A
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
“IndoorunitcombinationSAP-K(M)RV..6EH”
Cooling
Heating
Capacity (Min.-Max.) (kW)
Capacity (Min.-Max.) (kW)
Room A Room B Room C Room D
Total
Room A Room B Room C Room D
Total
7
2,20
2,2 (1,5-2,6) 2,50
2,5 (1,8-4,3)
9
2,65
2,65 (1,5-3,2) 3,60
3,6 (1,8-4,7)
12
3,50
3,5 (1,6-3,6) 4,20
4,2 (1,9-5,1)
1 room
18
5,15
5,15 (1,7-5,8) 6,00
6,0 (2,0-7,8)
24
7,10
7,1 (1,8-7,4) 8,50
8,5 (2,0-8,8)
7+7
2,20
2,20
4,4 (2,0-5,1) 2,50
2,50
5,0 (2,0-6,4)
7+9
2,20
2,65
4,85 (2,0-5,8) 2,50
3,60
6,1 (2,1-7,5)
7 + 12
2,20
3,50
5,7 (2,0-6,7) 2,50
4,20
6,7 (2,3-8,3)
7 + 18
2,14
5,01
7,15 (2,2-7,7) 2,50
6,00
8,5 (3,0-9,4)
7 + 24
1,81
5,84
7,65 (2,3-8,8) 2,01
6,84
8,85 (3,0-9,8)
9+9
2,65
2,65
5,3 (2,0-6,5) 3,60
3,60
7,2 (2,4-8,5)
9 + 12
2,54
3,36
5,9 (2,0-7,4) 3,51
4,09
7,6 (2,6-8,5)
2 rooms
9 + 18
2,46
4,79
7,25 (2,3-8,5) 3,24
5,41
8,65 (3,3-9,4)
9 + 24
2,11
5,64
7,75 (2,3-8,8) 2,68
6,32
9,0 (3,3-9,8)
12 + 12
3,40
3,40
6,8 (2,2-8,4) 4,00
4,00
8,0 (2,9-8,5)
12 + 18
3,03
4,47
7,5 (2,6-8,8) 3,60
5,15
8,75 (3,4-9,8)
12 + 24
2,61
5,29
7,9 (2,6-8,8) 3,01
6,09
9,1 (3,4-9,8)
18 + 18
3,95
3,95
7,9 (2,6-8,8) 4,50
4,50
9,0 (3,4-9,8)
18 + 24
3,36
4,64
8,0 (2,7-8,8) 3,89
5,51
9,4 (3,4-9,8)
7+7+7
2,20
2,20
2,20
6,6 (2,0-7,7) 2,50
2,50
2,50
7,5 (2,7-9,0)
7+7+9
2,20
2,20
2,65
7,05 (2,2-8,4) 2,47
2,47
3,56
8,5 (3,0-9,2)
7 + 7 + 12
2,03
2,03
3,23
7,3 (2,4-8,6) 2,34
2,34
3,93
8,6 (3,2-9,8)
7 + 7 + 18
1,77
1,77
4,15
7,7 (2,7-9,0) 2,01
2,01
4,83
8,85 (3,4-9,8)
7 + 7 + 24
1,53
1,53
4,94
8,0 (2,9-9,0) 1,71
1,71
5,82
9,25 (3,4-9,8)
7+9+9
2,11
2,54
2,54
7,2 (2,3-8,6) 2,23
3,21
3,21
8,65 (3,3-9,3)
7 + 9 + 12
1,95
2,35
3,10
7,4 (2,6-9,0) 2,12
3,06
3,57
8,75 (3,4-9,8)
7 + 9 + 18
1,72
2,07
4,02
7,8 (2,9-9,0) 1,86
2,68
4,46
9,0 (3,4-9,8)
7 + 9 + 24
1,47
1,77
4,75
8,0 (2,9-9,0) 1,61
2,32
5,47
9,4 (3,4-9,8)
7 + 12 + 12
1,82
2,89
2,89
7,6 (2,7-9,0) 2,03
3,41
3,41
8,85 (3,4-9,8)
7 + 12 + 18
1,60
2,55
3,75
7,9 (2,9-9,0) 1,79
3,01
4,30
9,1 (3,4-9,8)
7 + 12 + 24
1,38
2,19
4,44
8,0 (2,9-9,0) 1,55
2,60
5,26
9,4 (3,4-9,8)
7 + 18 + 18
1,41
3,30
3,30
8,0 (2,9-9,0) 1,62
3,89
3,89
9,4 (3,4-9,8)
3 rooms
7 + 18 + 24
1,22
2,85
3,93
8,0 (2,9-9,0) 1,38
3,32
4,70
9,4 (3,4-9,8)
9+9+9
2,43
2,43
2,43
7,3 (2,5-8,6) 2,95
2,95
2,95
8,85 (3,4-9,4)
9 + 9 + 12
2,26
2,26
2,98
7,5 (2,7-9,0) 2,81
2,81
3,28
8,9 (3,4-9,8)
9 + 9 + 18
2,00
2,00
3,89
7,9 (2,9-9,0) 2,51
2,51
4,18
9,2 (3,4-9,8)
9 + 9 + 24
1,71
1,71
4,58
8,0 (2,9-9,0) 2,16
2,16
5,09
9,4 (3,4-9,8)
9 + 12 + 12
2,13
2,81
2,81
7,75 (2,7-9,0) 2,70
3,15
3,15
9.0 (3,4-9,8)
9 + 12 + 18
1,88
2,48
3,65
8,0 (2,9-9,0) 2,43
2,83
4,04
9,3 (3,4-9,8)
9 + 12 + 24
1,60
2,11
4,29
8,0 (2,9-9,0) 2,08
2,42
4,90
9,4 (3,4-9,8)
9 + 18 + 18
1,64
3,18
3,18
8,0 (2,9-9,0) 2,17
3,62
3,62
9,4 (3,4-9,8)
12 + 12 + 12
2,65
2,65
2,65
7,95 (2,9-9,0) 3,03
3,03
3,03
9,1 (3,4-9,8)
12 + 12 + 18
2,30
2,30
3,39
8,0 (2,9-9,0) 2,73
2,73
3,90
9,35 (3,4-9,8)
12 + 12 + 24
1,99
1,99
4,03
8,0 (2,9-9,0) 2,34
2,34
4,73
9,4 (3,4-9,8)
12 + 18 + 18
2,03
2,99
2,99
8,0 (2,9-9,0) 2,44
3,48
3,48
9,4 (3,4-9,8)
1,88
1,88
1,88
7,5 (2,9-9,2) 2,18
2,18
2,18
2,18
8,7 (3,4-9,8)
7+7+7+7
1,88
7+7+7+9
1,82
1,82
1,82
2,19
7,65 (2,9-9,2) 1,99
1,99
1,99
2,87
8,85 (3,4-9,8)
7 + 7 + 7 + 12
1,71
1,71
1,71
2,72
7,85 (2,9-9,2) 1,91
1,91
1,91
3,21
8,95 (3,4-9,8)
7 + 7 + 7 + 18
1,50
1,50
1,50
3,51
8,0 (2,9-9,2) 1,71
1,71
1,71
4,11
9,25 (3,4-9,8)
7 + 7 + 7 + 24
1,28
1,28
1,28
4,15
8,0 (2,9-9,2) 1,47
1,47
1,47
4,99
9,4 (3,4-9,8)
7+7+9+9
1,76
1,76
2,12
2,12
7,75 (2,9-9,2) 1,85
1,85
2,67
2,67
9,05 (3,4-9,8)
7 + 7 + 9 + 12
1,66
1,66
2,00
2,64
7,95 (2,9-9,2) 1,79
1,79
2,57
3,00
9,15 (3,4-9,8)
7 + 7 + 9 + 18
1,44
1,44
1,74
3,38
8,0 (2,9-9,2) 1,61
1,61
2,32
3,86
9,4 (3,4-9,8)
7 + 7 + 9 + 24
1,24
1,24
1,50
4,01
8,0 (2,9-9,2) 1,37
1,37
1,98
4,67
9,4 (3,4-9,8)
7 + 7 + 12 + 12
1,54
1,54
2,46
2,46
8,0 (2,9-9,2) 1,72
1,72
2,88
2,88
9,2 (3,4-9,8)
7 + 7 + 12 + 18
1,35
1,35
2,15
3,16
8,0 (2,9-9,2) 1,55
1,55
2,60
3,71
9,4 (3,4-9,8)
7 + 7 + 18 + 18
1,20
1,20
2,80
2,80
8,0 (2,9-9,2) 1,38
1,38
3,32
3,32
9,4 (3,4-9,8)
7+9+9+9
1,70
2,05
2,05
2,05
7,85 (2,9-9,2) 1,73
2,49
2,49
2,49
9,2 (3,4-9,8)
4 rooms
7 + 9 + 9 + 12
1,60
1,93
1,93
2,55
8,0 (2,9-9,2) 1,67
2,41
2,41
2,81
9,3 (3,4-9,8)
7 + 9 + 9 + 18
1,39
1,68
1,68
3,26
8,0 (2,9-9,2) 1,50
2,16
2,16
3,59
9,4 (3,4-9,8)
7 + 9 + 12 + 12
1,49
1,79
2,36
2,36
8,0 (2,9-9,2) 1,62
2,33
2,72
2,72
9,4 (3,4-9,8)
7 + 9 + 12 + 18
1,30
1,57
2,07
3,05
8,0 (2,9-9,2) 1,44
2,08
2,42
3,46
9,4 (3,4-9,8)
7 + 12 + 12 + 12
1,39
2,20
2,20
2,20
8,0 (2,9-9,2) 1,56
2,61
2,61
2,61
9,4 (3,4-9,8)
7 + 12 + 12 + 18
1,23
1,95
1,95
2,87
8,0 (2,9-9,2) 1,39
2,34
2,34
3,34
9,4 (3,4-9,8)
9+9+9+9
2,00
2,00
2,00
2,00
8,0 (2,9-9,2) 2,35
2,35
2,35
2,35
9,4 (3,4-9,8)
9 + 9 + 9 + 12
1,85
1,85
1,85
2,45
8,0 (2,9-9,2) 2,26
2,26
2,26
2,63
9,4 (3,4-9,8)
9 + 9 + 9 + 18
1,62
1,62
1,62
3,15
8,0 (2,9-9,2) 2,01
2,01
2,01
3,36
9,4 (3,4-9,8)
9 + 9 + 12 + 12
1,72
1,72
2,28
2,28
8,0 (2,9-9,2) 2,17
2,17
2,53
2,53
9,4 (3,4-9,8)
9 + 9 + 12 + 18
1,52
1,52
2,01
2,95
8,0 (2,9-9,2) 1,94
1,94
2,27
3,24
9,4 (3,4-9,8)
9 + 12 + 12 + 12
1,61
2,13
2,13
2,13
8,0 (2,9-9,2) 2,09
2,44
2,44
2,44
9,4 (3,4-9,8)
12 + 12 + 12 + 12
2,00
2,00
2,00
2,00
8,0 (2,9-9,2) 2,35
2,35
2,35
2,35
9,4 (3,4-9,8)
The table lists the wall-mounted type of indor units as representative models. For details on the connection of indoor units other than the wall mounted type, refer to the technical data.
All Specifications subject to change without notice. .
Rated capacity (kW)
Cooling/Heating : 8.0/9.4
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
37
Flexi Multi
5 in 1
Room Air Conditioners
SAP-CMRV3656EH
SANYO’s new 5 in 1 Flexi Multi DC Inverter Heat
Pump now allows the connection of up to five
indoor units.
SAP-CMRV3656EH
SAP-URV....EH
SAP-FTRV....EH
SAP-K(M)RV....EH
SAP-KRV....EHDS
SAP-FRV....EH
Remote
• Energy class A both in cooling and heating operation
Heat- Pump Inverter
External units
SAP-CMRV3656EH
Performance
Cooling
Heating
Capacity kW
1,6/10,0/11,5
1,6/12,0/14,5
Power consumption W
2860
2860
EER/COP W/W
3,50
4,20
Energy class
A
A
Max. number of units N.
5
Sound pressure dB(A)
53/47(quiet mode)
Pipe diameter - suction/discharge mm(in)
2x6.4(1/4) 2x9.5(3/8)
Maximum total pipe length m
80
Maximum pipe length per unit m
30
Max. elevation difference E.U - I.U m
15
Total pipe length - standard charge m
45
Dimensions (HxLxD) mm
910x940x340
Power supply V,ph,Hz
220 - 240V, 1ph, 50Hz
Specifications subject to change without notice.
• Operation range down to -15°C in heating and -10°C in
cooling operation
• D
C inverter technology for precise temperature control and
a low start-up current
• T win rotary compressor: the dual rotors guarantee perfect
balancing ensuring functional reliability and efficiency. This
also contributes to increase comfort and accelerate cooling
and heating as well as ensuring an extremely quiet and
efficient operation.
Pr
• N
on-stop heating by means of SANYO’s exclusive hot gas
by-pass system
• Renewable and washable apatite ceramic filter
• P
hoto-catalytic LED sterilization function ensures excellent
performance in eliminating odours, germs and bacteria (only
wall-mounted units)
SAP-XRV....EH
n
i
m
i
el
a
ta
a
D
ry
Flexi Multi System Example
• N
ight Set back/Economy modes to guarantee quiet and
energy-efficient cooling and heating
• Programmable start-up and shut-off via 24 hour clock
Outdoor
38
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Indoor
Outdoor
Indoor
43°C DB
32°C DB
18°C WB
27°C DB
-10°C DB
19°C DB
-15°C WB
16°C DB
Energy class
A
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
R410A
39
Flexi Multi
5 in 1 (continued)
Room Air Conditioners
SAP-CMRV3656EH
Pr
y
Rated capacity (kW)
Total
2,50 (1,8-4,3)
3,60 (1,8-4,7)
4,20 (1,9-5,1)
6,00 (2,0-7,8)
8,50 (2,0-8,8)
5,00 (2,0-6,4)
6,10 (2,1-7,5)
6,70 (2,3-8,3)
8,50 (3,0-9,4)
8,85 (3,0-9,8)
7,20 (2,4-8,5)
7,60 (2,6-8,5)
8,65 (3,3-9,4)
9,00 (3,3-9,8)
8,00 (2,9-8,5)
8,75 (3,4-9,8)
9,10 (3,4-9,8)
9,00 (3,4-9,8)
9,40 (3,4-9,8)
9,40 (3,4-9,8)
7,50 (2,7-9,0)
8,50 (3,0-9,2)
8,60 (3,2-9,8)
8,85 (3,4-9,8)
9,25 (3,4-9,8)
8,65 (3,3-9,3)
8,75 (3,4-9,8)
9,00 (3,4-9,8)
9,80 (3,4-9,8)
8,85 (3,4-9,8)
9,10 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
8,85 (3,4-9,4)
8,90 (3,4-9,8)
9,20 (3,4-9,8)
9,80 (3,4-9,8)
9,00 (3,4-9,8)
9,30 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,10 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
4 rooms
5 rooms
R410A
40
Energy class
A
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
7+7+7+7
7+7+7+9
7+7+7+12
7+7+7+18
7+7+7+24
7+7+9+9
7+7+9+12
7+7+9+18
7+7+9+24
7+7+12+12
7+7+12+18
7+7+12+24
7+7+18+18
7+7+18+24
7+9+9+9
7+9+9+12
7+9+9+18
7+9+9+24
7+9+12+12
7+9+12+18
7+9+12+24
7+9+18+18
7+9+18+24
7+12+12+12
7+12+12+18
7+12+12+24
7+12+18+18
9+9+9+9
9+9+9+12
9+9+9+18
9+9+9+24
9+9+12+12
9+9+12+18
9+9+12+24
9+9+18+18
9+9+18+24
9+12+12+12
9+12+12+18
9+12+12+24
12+12+12+12
12+12+12+18
7+7+7+7+7
7+7+7+7+9
7+7+7+7+12
7+7+7+7+18
7+7+7+7+24
7+7+7+9+9
7+7+7+9+12
7+7+7+9+18
7+7+7+9+24
7+7+7+12+12
7+7+7+12+18
7+7+7+12+24
7+7+9+9+9
7+7+9+9+12
7+7+9+9+18
7+7+9+9+24
7+7+9+12+12
7+7+9+12+18
7+7+12+12+12
7+9+9+9+9
7+9+9+9+12
7+9+9+9+18
7+9+9+9+24
7+9+9+12+12
7+9+9+12+18
7+9+9+12+19
9+9+9+9+9
9+9+9+9+12
9+9+9+9+18
9+9+9+9+24
9+9+9+12+12
9+9+12+12+12
9+9+12+12+18
Room A
1,88
1,82
1,71
1,59
1,48
1,76
1,66
1,53
1,43
1,64
1,55
1,35
1,38
1,22
1,70
1,66
1,53
1,36
1,60
1,47
1,31
1,34
1,18
1,59
1,41
1,24
1,27
2,00
1,94
1,82
1,62
1,90
1,75
1,53
1,56
1,39
1,81
1,65
1,46
2,30
2,06
2,00
1,92
1,79
1,58
1,38
1,85
1,73
1,53
1,35
1,62
1,44
1,28
1,78
1,67
1,48
1,31
1,57
1,40
1,48
1,72
1,61
1,44
1,28
1,52
1,36
1,43
2,00
1,88
1,68
1,50
1,77
1,68
1,52
Room B
1,88
1,82
1,71
1,59
1,48
1,76
1,66
1,53
1,43
1,64
1,55
1,35
1,38
1,22
2,05
2,00
1,84
1,63
1,92
1,77
1,58
1,61
1,43
2,54
2,24
1,98
2,01
2,00
1,94
1,82
1,62
1,90
1,75
1,53
1,56
1,39
2,40
2,18
1,92
2,30
2,06
2,00
1,92
1,79
1,58
1,38
1,85
1,73
1,53
1,35
1,62
1,44
1,28
1,78
1,67
1,48
1,31
1,57
1,40
1,48
2,07
1,94
1,73
1,54
1,83
1,64
1,73
2,00
1,88
1,68
1,50
1,77
1,68
1,52
Capacity (Min.-Max.) (kW)
Room C Room D Room E
1,88
1,88
1,82
2,19
1,71
2,72
1,59
3,73
1,48
4,77
2,12
2,12
2,00
2,64
1,85
3,59
1,72
4,62
2,61
2,61
2,47
3,63
2,15
4,35
3,22
3,22
2,85
3,92
2,05
2,05
2,00
2,64
1,84
3,58
1,63
4,38
2,54
2,54
2,33
3,43
2,08
4,23
3,13
3,13
2,77
3,82
2,54
2,54
2,24
3,30
1,98
4,01
2,96
2,96
2,00
2,00
1,94
2,57
1,82
3,54
1,62
4,34
2,50
2,50
2,31
3,40
2,03
4,11
3,04
3,04
2,70
3,72
2,40
2,40
2,18
3,20
1,92
3,90
2,30
2,30
2,06
3,03
2,00
2,00
2,00
1,92
1,92
2,31
1,79
1,79
2,85
1,58
1,58
3,69
1,38
1,38
4,47
1,85
2,23
2,23
1,73
2,08
2,75
1,53
1,84
3,58
1,35
1,62
4,34
1,62
2,57
2,57
1,44
2,30
3,38
1,28
2,03
4,13
2,15
2,15
2,15
2,01
2,01
2,65
1,78
1,78
3,47
1,58
1,58
4,23
1,89
2,49
2,49
1,69
2,23
3,28
2,35
2,35
2,35
2,07
2,07
2,07
1,94
1,94
2,56
1,73
1,73
3,37
1,54
1,54
4,12
1,83
2,41
2,41
1,64
2,17
3,19
2,28
2,28
2,28
2,00
2,00
2,00
1,88
1,88
2,48
1,68
1,68
3,27
1,50
1,50
4,01
1,77
2,34
2,34
2,22
2,22
2,22
2,01
2,01
2,95
Total
7,50 (2,9-10,5)
7,65 (2,9-10,5)
7,85 (2,9-10,5)
8,50 (2,9-10,5)
9,20 (2,9-10,5)
7,75 (2,9-10,5)
7,95 (2,9-10,5)
8,50 (2,9-10,5)
9,20 (2,9-10,5)
8,50 (2,9-10,5)
9,20 (2,9-10,5)
9,20 (2,9-10,5)
9,20 (2,9-10,5)
9,20 (2,9-10,5)
7,85 (2,9-10,5)
8,30 (2,9-10,5)
8,80 (2,9-10,5)
9,00 (2,9-10,5)
8,60 (2,9-10,5)
9,00 (2,9-10,5)
9,20 (2,9-10,5)
9,20 (2,9-10,5)
9,20 (2,9-10,5)
9,20 (2,9-10,5)
9,20 (2,9-10,5)
9,20 (2,9-10,5)
9,20 (2,9-10,5)
8,00 (2,9-10,5)
8,40 (2,9-10,5)
9,00 (2,9-10,5)
9,20 (2,9-10,5)
8,80 (2,9-10,5)
9,20 (2,9-10,5)
9,20 (2,9-10,5)
9,20 (2,9-10,5)
9,20 (2,9-10,5)
9,00 (2,9-10,5)
9,20 (2,9-10,5)
9,20 (2,9-10,5)
9,20 (2,9-10,5)
9,20 (2,9-10,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
10,00 (3,5-11,5)
Room A
2,18
1,99
1,91
1,71
1,53
1,85
1,79
1,68
1,43
1,72
1,61
1,38
1,44
1,26
1,73
1,67
1,56
1,35
1,69
1,50
1,30
1,35
1,19
1,62
1,45
1,26
1,31
2,45
2,35
2,10
1,83
2,26
2,03
1,77
1,84
1,63
2,18
1,96
1,72
2,45
2,21
2,40
2,21
2,11
1,88
1,62
2,04
1,96
1,75
1,53
1,89
1,69
1,49
1,90
1,83
1,65
1,45
1,76
1,60
1,70
1,78
1,71
1,55
1,38
1,66
1,51
1,60
2,40
2,32
2,12
1,89
2,25
2,18
2,00
Room B
2,18
1,99
1,91
1,71
1,53
1,85
1,79
1,68
1,43
1,72
1,61
1,38
1,44
1,26
2,49
2,41
2,25
1,94
2,43
2,16
1,88
1,95
1,71
2,73
2,44
2,12
2,20
2,45
2,35
2,10
1,83
2,26
2,03
1,77
1,84
1,63
2,54
2,29
2,01
2,45
2,21
2,40
2,21
2,11
1,88
1,62
2,04
1,96
1,75
1,53
1,89
1,69
1,49
1,90
1,83
1,65
1,45
1,76
1,60
1,70
2,56
2,47
2,24
1,98
2,39
2,17
2,31
2,40
2,32
2,12
1,89
2,25
2,18
2,00
Capacity (Min.-Max.) (kW)
Room C Room D Room E
2,18
2,18
1,99
2,87
1,91
3,21
1,71
4,11
1,53
5,21
2,67
2,67
2,57
3,00
2,42
4,03
2,06
4,87
2,88
2,88
2,71
3,87
2,33
4,71
3,46
3,46
3,02
4,27
2,49
2,49
2,41
2,81
2,25
3,75
1,94
4,58
2,84
2,84
2,53
3,61
2,19
4,43
3,25
3,25
2,85
4,04
2,73
2,73
2,44
3,48
2,12
4,29
3,14
3,14
2,45
2,45
2,35
2,74
2,10
3,50
1,83
4,32
2,64
2,64
2,37
3,38
2,07
4,19
3,06
3,06
2,71
3,84
2,54
2,54
2,29
3,27
2,01
4,06
2,45
2,45
2,21
3,16
2,40
2,40
2,40
2,21
2,21
3,18
2,11
2,11
3,55
1,88
1,88
4,50
1,62
1,62
5,51
2,04
2,94
2,94
1,96
2,82
3,29
1,75
2,53
4,21
1,53
2,20
5,20
1,89
3,17
3,17
1,69
2,85
4,07
1,49
2,50
5,05
2,73
2,73
2,73
2,63
2,63
3,07
2,37
2,37
3,96
2,09
2,09
4,93
2,54
2,96
2,96
2,30
2,68
3,83
2,86
2,86
2,86
2,56
2,56
2,56
2,47
2,47
2,88
2,24
2,24
3,73
1,98
1,98
4,68
2,39
2,78
2,78
2,17
2,53
3,62
2,70
2,70
2,70
2,40
2,40
2,40
2,32
2,32
2,71
2,12
2,12
3,53
1,89
1,89
4,45
2,25
2,63
2,63
2,55
2,55
2,55
2,33
2,33
3,33
Da
ta
Capacity (Min.-Max.) (kW)
Room C Room D Room E
2,50
3,56
3,93
4,83
5,82
3,21
3,57
4,46
5,71
3,41
4,30
5,48
4,06
4,90
2,95
3,28
4,18
5,31
3,15
4,04
5,11
3,77
4,60
3,03
4,08
4,93
3,63
4,45
3,27
4,06
-
Heating
y
Room B
2,50
3,60
4,20
6,00
6,84
3,60
4,09
5,41
6,32
4,00
5,15
6,09
4,50
5,51
4,70
2,50
2,47
2,34
2,01
1,71
3,21
3,06
2,68
2,42
3,41
3,01
2,71
4,06
3,46
2,95
2,81
2,51
2,25
3,15
2,83
2,53
3,77
3,25
3,03
2,86
2,44
3,63
3,14
3,27
2,87
in
Room A
2,50
3,60
4,20
6,00
8,50
2,50
2,50
2,50
2,50
2,01
3,60
3,51
3,24
2,68
4,00
3,60
3,01
4,50
3,89
4,70
2,50
2,47
2,34
2,01
1,71
2,23
2,12
1,86
1,68
2,03
1,79
1,61
1,69
1,44
2,95
2,81
2,51
2,25
2,70
2,43
2,16
2,26
1,95
3,03
2,86
2,44
2,54
2,20
3,27
2,87
Da
ta
Total
2,20 (1,5-2,6)
2,65 (1,5-3,2)
3,50 (1,6-3,6)
5,15 (1,7-5,8)
7,10 (1,8-7,4)
4,40 (2,0-5,1)
4,85 (2,0-5,8)
5,70 (2,0-6,7)
7,15 (2,2-7,7)
7,65 (2,3-8,8)
5,30 (2,0-6,5)
5,90 (2,0-7,4)
7,25 (2,3-8,5)
7,75 (2,3-8,8)
6,80 (2,2-8,4)
7,50 (2,6-8,8)
7,90 (2,6-9,5)
7,90 (2,6-9,5)
8,80 (2,7-9,5)
8,80 (2,7-9,5)
6,60 (2,0-7,7)
7,05 (2,2-8,4)
7,30 (2,4-8,6)
7,70 (2,7-9,0)
8,60 (2,9-10,0)
7,20 (2,3-8,6)
7,40 (2,6-9,0)
7,80 (2,9-9,0)
8,70 (2,9-10,0)
7,60 (2,7-9,0)
7,90 (2,9-9,0)
9,00 (2,9-10,0)
9,00 (2,9-9,0)
9,00 (2,9-10,0)
7,30 (2,5-8,6)
7,50 (2,7-9,0)
7,90 (2,9-9,0)
9,00 (2,9-10,0)
7,75 (2,7-9,0)
8,50 (2,9-9,0)
9,00 (2,9-10,0)
9,00 (2,9-9,0)
9,00 (2,9-10,0)
7,95 (2,9-9,0)
9,00 (2,9-9,0)
9,00 (2,9-10,0)
9,00 (2,9-10,0)
9,00 (2,9-10,0)
9,00 (2,9-10,0)
9,00 (2,9-10,0)
Cooling
im
el
3 rooms
Capacity (Min.-Max.) (kW)
Room C Room D Room E
2,20
2,65
3,23
4,15
5,31
2,54
3,10
4,02
5,17
2,89
3,75
4,99
3,71
4,42
2,43
2,98
3,89
5,15
2,81
3,87
4,82
3,58
4,29
2,65
3,81
4,53
3,36
4,06
3,00
3,67
-
in
2 rooms
Room B
2,20
2,65
3,50
5,01
5,84
2,65
3,36
4,79
5,64
3,40
4,47
5,29
3,95
5,10
4,40
2,20
2,20
2,03
1,77
1,65
2,54
2,35
2,07
1,93
2,89
2,55
2,46
3,71
3,21
2,43
2,26
2,00
1,92
2,81
2,63
2,38
3,58
3,11
2,65
2,59
2,23
3,36
2,94
3,00
2,66
im
1 room
7
9
12
18
24
7+7
7+9
7+12
7+18
7+24
9+9
9+12
9+18
9+24
12+12
12+18
12+24
18+18
18+24
24+24
7+7+7
7+7+9
7+7+12
7+7+18
7+7+24
7+9+9
7+9+12
7+9+18
7+9+24
7+12+12
7+12+18
7+12+24
7+18+18
7+18+24
9+9+9
9+9+12
9+9+18
9+9+24
9+12+12
9+12+18
9+12+24
9+18+18
9+18+24
12+12+12
12+12+18
12+12+24
12+18+18
12+18+24
18+18+18
18+18+24
Room A
2,20
2,65
3,50
5,15
7,10
2,20
2,20
2,20
2,14
1,81
2,65
2,54
2,46
2,11
3,40
3,03
2,61
3,95
3,70
4,40
2,20
2,20
2,03
1,77
1,65
2,11
1,95
1,72
1,60
1,82
1,60
1,55
1,58
1,37
2,43
2,26
2,00
1,92
2,13
1,99
1,80
1,84
1,60
2,65
2,59
2,23
2,28
2,00
3,00
2,66
ar
Rated capacity (kW)
“Indoor unit c­ ombination
SAP-K(M)RV..6EH”
Heating
el
Cooling
Pr
“Indoor unit ­combination
SAP-K(M)RV..6EH”
ar
SAP-CMRV3656EH
Total
8,70 (3,4-9,8)
8,85 (3,4-9,8)
8,95 (3,4-9,8)
9,25 (3,4-9,8)
9,80 (3,4-9,8)
9,05 (3,4-9,8)
9,15 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,20 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,20 (3,4-9,8)
9,30 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
9,80 (3,4-9,8)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
12,00 (4,0-14,5)
The table lists the wall-mounted type of indor units as representative models. For details on the connection of indoor units other than the wall mounted type, refer to the technical data.
Specifications subject to change without notice.
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
41
Commercial Split-Systems (PACi)
Content
Commercial
Split-Systems
(PACi)
PACi Commercial Split Systems – Overview
44
PACi Hydronic Split Systems 48
Elite PACi 50
Classic PACi 51
PACi Indoor Units 52
Big PACi 64
Multi Systems 66
Convenient System Control 42
128
43
PACi Commercial Split-Systems
Commercial Split-Systems (PACi)
High Performance SPW R410A DC Inverter Split Systems
Only recently SANYO’s experienced design engineers have gone back to the drawing board and completely
overhauled our range of Commercial Split Systems. After extensive research and development we have
unveiled the Elite PACi. With its advanced features and superior design, the Elite PACi is one of the top
performing split systems in the industry.
Taking inverter technology to a new level of comfort
Twin rotary compressor
The SPW DC Inverters use Advanced Digital Hybrid (ADH)
technology for better, smarter and more cost-efficient year
round climate control. Immediately following start-up, the DC
compressor operates at maximum power to provide almost
instant heating or cooling. As the desired air temperature is
reached, a special Pulse Width Module automatically adjusts
the compressor’s frequency to exactly meet the cooling or
heating requirements of the room. The result is exceptionally
precise temperature control, less noise and significant energy
savings.
The SPW outdoor units utilise the latest SANYO twin rotary
compressor, in which perfectly balanced dual rotors revolve
smoothly and efficiently to provide powerful, quiet and
vibration-free performance.
The DC motor uses powerful neodymium magnets, which are
approximately 15-20 times stronger than the ferrite magnets
used in conventional AC compressors. This, combined with
precise digital control, gives the SANYO DC compressor an
operation rate 15-20% higher than that of a conventional AC
compressor.
Elite PACi
Classic PACi
The expanded range of Commercial Split System is of superior
performance and quality, providing more choice for customers.
Specifically designed for commercial and retail applications,
the ingenious design of the systems not only overcomes the
limitations associated with the installation of traditional split
systems, but also offers the end user improved comfort and
drastically reduced power consumption.
Big PACi
lengthened, either slowing the compressor to reduce capacity
for the nominal figure (measured at 50Hz) or increasing its
speed to offer increased output.
Other factors, such as coil size, restrict the maximum output
of the system and SANYO would recommend that equipment
is always selected at nominal capacity to ensure the optimum
lifespan of the equipment.
Wide range of indoor units
Not only have the PACi range of outdoor units been completely
overhauled, but also our range of indoor units are perfect for a
wide variety of applications.
All these units are high-performance and benefits from many
features - just as you would expect from SANYO. They are also
designed with the needs of the installer as well as the end user
in mind, making installation and maintenance a breeze.
All SANYO SPW DC inverter systems are highly rated on
EEL, which confirms that they are amongst the most energyefficient systems available. Power consumption during
operation is substantially less than that of lower rated units
and consequently both the day to day running costs and full life
cycle costs are significantly reduced.
• Single or three phase power supply across the range
• Low start current of indoor units
• Systems pre-charged for 30 metres
• Pipe runs up to 100 metres
The SPW DC inverter systems utilise the non‑ozone depleting
R410A refrigerant, which gives increased system performance,
increased energy-efficiency and improved heat transfer, which
results in smaller pipe sizes and more compact indoor units.
Range extends from 5kW through to 25kW
The Elite PACi benefits from increased performance and
efficiency, with COP ratings that are some of the highest in the
industry. For higher capacities, SANYO’s Big PACi is a newly
compact design with a twin fan, saving valuable installation
space compared to traditional 8-10HP systems.
When comparing the COPs of DC inverter systems (which
are stated at 100% capacity) with an equivalent fixed speed
system, the improved energy-efficiency and consequent lower
running costs of the DC inverter can be easily calculated.
However, DC Inverters control the room temperature far
more precisely, generally operating in part load conditions
where the COPs are considerably higher, thereby delivering
further substantial energy savings and ensuring that this new
technology has an almost immediate payback.
Room Temp
• Single, twin, triple and quad options
°C
30
25
Heating
20
DC inverter-controlled compressors have an operating range
of 25-90Hz, which enables the sine wave to be shortened or
Room temp.
DC Inverter air conditioner
Conventional air conditioner
Desired
temperature
0˚C
Time until desired temperature is reached
Time
Desired
temperature
Cooling
DC Inverter air conditioner
15
Room temp.
-20
0
15
Conventional air conditioner
43 ˚C
Outdoor Ambient Temp.
* Cooling operation -20°C to 43°C
* Heating operation -20°C to 15°C
Note Heating operation is only for Heat pump model.
Standard PACi heating operation down to -15°C.
Wide capacity range
44
Cooling Mode
Affordable technology
0˚C
Time until desired temperature is reached
Time
Operation range (cooling and heat pump model)
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
45
PACi Range Overview
Commercial Split-Systems (PACi)
Indoor units
Capacity
cooling/heating
Class
kW
BTU/h
KR type
12
3,6
12,000
16
4,2
14,000
4,5
15,000
18
45,2
17,500
5,0
17,000
25
5,6
19,000
7,1
24,000
36
8,0
27,000
10,0
34,000
48
11,2
38,000
12,5
42,500
60
14,0
48,000
14,0
48,000
70
16,0
54,500
SPW-KR124GH56B
SPW-KR164GH56B
SPW-KR184GH56B
SPW-KR254GH56B
T type
SPW-T125H
SPW-T165H
SPW-T185H
SPW-T255H
SPW-T365H
SPW-T485H
SPW-T605H
X type
SPW-X125H
Panel
PNR-XD484GHAB
SPW-X165H
Panel
PNR-XD484GHAB
SPW-X185H
Panel
PNR-XD484GHAB
SPW-X255H
Panel
PNR-XD484GHAB
SPW-X365H
Panel
PNR-XD484GHAB
SPW-X485H
Panel
PNR-XD484GHAB
SPW-X605H
Panel
PNR-XD484GHAB
SPW-XM125H
Panel
PNR-XM185
SPW-XM165H
Panel
PNR-XM185
SPW-XM185H
Panel
PNR-XM185
SPW-XMR124EH56B
Panel
PNR-XM184EHAB
SPW-XMR164EH56B
Panel
PNR-XM484EHAB
SPW-XMR184EH56B
Panel
PNR-XM484EHAB
SPW-US125H
SPW-US165H
SPW-US185H
UMR type
SPW-UMR124EH56B
SPW-UMR164EH56B
SPW-UMR184EH56B
FTR type
SPW-FTR124EH56B
SPW-FTR164EH56B
SPW-FTR184EH56B
SPW-U125H
SPW-U165H
SPW-U185H
SPW-U255H
SPW-U365H
SPW-U485H
SPW-U605H
SPW-U185SHT
SPW-U255SHT
SPW-U365SHT
SPW-U485SHT
SPW-U605SHT
XM type
XMR type
US type
U type
UR type with filter
D type
20,0
68,200
90
22,4
76,400
25,0
85,300
SPW-D0705H
Long life filter
28,0
95,500
Functions
SPW-D0905H
Built-in drain pump
Automatic flap
Automatic swing
Outdoor units
Capacity
cooling/heating
HP
Class
kW
BTU/h
2
18
5,0
17,000
3
25
5,6
19,000
7,1
24,000
4
36
8,0
27,500
10,0
34,000
5
48
11,2
38,000
12,5
42,500
6
60
14,0
48,000
14,0
48,000
8
70
16,0
54,500
Elite PACi
1 phase: 220-240V; 50/60Hz
3 phase: 380-415V; 50Hz
20,0
68,200
10
90
22,4
76,400
25,0
85,300
28,0
95,500
BIG PACi
SPW-C186VEH
–
SPW-C256VEH
SPW-C256VEH8
SPW-C366VEHN
SPW-C366VEH8
SPW-C486VEHN
SPW-C486VEH8
SPW-C606VEHN
SPW-C606VEH8
–
SPW-C706VH8
–
SPW-C906VH8
–
–
SPW-C256VH
SPW-C256VH8
SPW-C366VH
SPW-C366VH8
SPW-C486VH
SPW-C486VH8
–
SPW-C606VH8
–
–
–
–
Classic PACi
1 phase: 220-240V; 50/60Hz
3 phase: 380-415V; 50Hz
46
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
47
PAC-i Hydronic Split Systems
Commercial Split-Systems (PACi)
kW
A
m3/h
kPa
48
Da
ta
Da
ta
ry
-
-
40
-
na
12
400/3/50
0,33
1,42
45
mi
0,33
1,4
52
eli
Da
ta
ry
10 HP
906HH8-E
906H8-E
-
1”1/4”
110
120
Last update: 17th of February 2009
inches
mm
kg
V/Ph/Hz
kW
A
5 HP
486VEHN
486HH58-E
486H58-E
72
54
6600
-16 to 35
10 to 43
1 x Twin Rotary
1
R410A
3,6
3
10
3/8” Liquid tube
5/8” Gas tube
940/410/1330
1,65
1/4”
1/2”
790/285/569
41
3
-
2,2
-
780/340/940
54
90
230/1/50
4,4
3
3,37
3
10 HP
906VH8
906HH8-E
906H8-E
-
Da
ta
7740
-16 to 20
10 to 43
5,3
-
6,5
-
1/2”
3/4”
1526/340/940
95
4,98
3
23
16,5
8 HP
706VH8
706HH8-E
706H8-E
-
ry
-16 to 20
10 to 43
6 HP
606VEHN
606HH58-E
606H58-E
73
56
na
kg
m
m
4 HP
366VEHN
366HH5-E
366H5-E
70
53
mi
m3/h
°C
3 HP
256VEH
256HH5-E
256H5-E
3360
eli
Dimensions Outdoor Unit (W/D/H)
Weight
Power supply
Max power input
Starting current
Max operation current
dB(A)
2 HP
186VEH
186HH5-E
186H5-E
2100
5,59
3
27
118
400/3/50
7,6
12,5
Pr
10 HP
906VH8
906HH8-E
906H8-E
25,2
3,66
25
3,55
7,04
11
4,34
45
16,2
2,19
13,9
2,08
23,5
3,09
23,7
3,05
7,76
12,2
4,08
46
ry
na
mi
Da
ta
ry
na
Gross: Performance according to Eurovent standard (excluding circulation pump)
Net: Performance according to the EN14511 standard (including circulation pump)
8 HP
706VH8
706HH8-E
706H8-E
20,2
3,74
20
3,6
5,55
8,7
3,48
52
13
2,23
11
2,09
18,8
3,18
19
3,13
6,06
9,5
3,27
54
eli
kW
30
Da
ta
Basic key components for the hydronic circuit are equipped in
the Hydronic module. Thus the installation work becomes
much easier.
Pr
kW
mi
kW
eli
kW
A
m3/h
kPa
kW
Pr
kW
0,13
0,55
42
3/4”
ry
Easy system installation
Modele / Model Outdoor unit SPW-C…
Indoor Unit with heater SPW-W…
Indoor Unit without heater SPW-W…
Sound power level
Sound pressure level
Air flow rate
Operation range Heating
Operation range Cooling
Compressor
Refrigerant circuit
Refrigerant
Refrigerant charge
Min piping length
Max piping length
Refrigerant piping dimension
(Outdoor to Hydro Box)
kW
0,12
0,5
47
na
Note: The controller is included in the Hydronic module.
Capacity and efficiency data
Modele / Model Outdoor unit SPW-C…
Indoor Unit with heater SPW-W…
Indoor Unit without heater SPW-W…
Nominal heating capacity (Gross) A7/6 W30/35
COP (Gross) A7/6 W30/35
Nominal heating capacity (Net ) A7/6 W30/35
COP (Net) A7/6 W30/35
Nominal power input (Net)
Nominal running current
Nominal water flow (Net)
External static pressure (Pump)
Nominal heating capacity (Net) A2/1 W*/35
COP A2/1 W*/35 (Net) A2/1 W*/35
Nominal heating capacity (Net) A-7/-8 W*/35
COP (Net) A-7/-8 W*/35
Nominal Cooling capacity (Gross) A35 W23/18
EER (Gross) A35 W23/18
Nominal Cooling capacity (Net) A35 W23/18
EER (Net ) A35 W23/18
Nominal power input (Net) A35 W23/18
Nominal running current
Nominal water flow
External static pressure (Pump)
4,5
3 or 4,5
230/1/50
8 HP
706HH8-E
706H8-E
Outdoor unit specification data
It creates the optimal warm / cool water flow for the
Hydronic system.
6 HP
606VEHN
606HH58-E
606H58-E
15,4
3,94
15,3
3,84
3,98
21,3
2,65
40
9,8
2,31
8,7
2,3
15,6
3,39
15,7
3,34
4,7
25,7
2,7
40
4,5
mi
The special remote controller regulates the most suitable
operation by sensing the ambient conditions.
5 HP
486VEHN
486HH58-E
486H58-E
13,6
4,08
13,5
3,94
3,43
18,8
2,3
42
8,55
2,6
7,7
2,4
13,4
3,69
13,5
3,65
3,7
20,7
2,3
42
l
kW
V/Ph/Hz
kW
A
kPa
inches
l
l
l
eli
The HYDRONIC Split System can be used not only for
Heating but also for Cooling applications.
Its high performance and the wide choice are suitable for
different kinds of demands.
Various applications
5 types of applications are available:
• 1 zone floor application
• 2 zone floor application
• 1 zone fan coil unit application
• mixed 2 zone application (floor & fan coil unit)
• 1 zone radiator application
Specific accessory parts for the above applications are
also available.
4 HP
366VEHN
366HH5-E
366H5-E
10,4
4,07
10,3
3,91
2,63
14,2
1,8
45
7,2
2,6
5,78
2,3
9,4
3,7
9,5
3,64
2,61
13
1,72
46
°C
Pr
Optimised control system for Hydronic circuit
3 HP
256VEH
256HH5-E
256H5-E
7,85
3,73
7,8
3,68
2,12
11
1,34
42
5,2
2,33
4,4
2,25
6,95
3,56
7
3,48
2,01
9,9
1,2
44
-
(*) If water content of the system is below minimum the installation of a storage tank is necessary
(**) If water content of the system is upper maximum the installation of an expansion tank is necessary.
Warm & Cool water utilisation
2 HP
186VEH
186HH5-E
186H5-E
5,45
3,95
5,4
3,8
1,42
7,3
0,93
47
3,6
2,39
3,2
2,3
4,95
3,84
5
3,7
1,35
6,6
0,86
48
-
4 HP
5 HP
6 HP
366HH5-E
486HH58-E
606HH58-E
366H5-E
486H58-E
606H58-E
Reversible (Heating and Cooling)
527/285/824
42
43
44
25 to 50
-5 to 20
4,7
4,9
5,1
6 (1Ph), 6 or 9 (3Ph)
4 or 6
230/1/50, 400/3/50
0,16
0,17
0,17
0,7
0,72
0,74
45
42
40
1”
6
50
65
75
200
Pr
SPW-W…H(H)5
SPW-W…H(H)58
SPW-W…H(H)8
mm
kg
3 HP
256HH5-E
256H5-E
na
Remote
2 HP
186HH5-E
186H5-E
mi
The SANYO Hydronic Split System
­provides more powerful and
comfortable Heating & Cooling.
Unit
-
eli
Specification data Hydro Box
Hydro Box Data
Indoor module with heater SPW-W…
Indoor module without heater SPW-W…
Function
Dimensions Hydro Kit
W/D/H
Weight with heater
Heating
Leaving water
­temperature range
Cooling
Water content indoor unit
Electrical heater
Power supply
Nominal capacity pump
Nominal current pump
External static pressure
Water circuit in/outlet
Expansion tank
Min water content (*)
Max water content (**)
Pr
SPW-W…H(H)5
SPW-W…H(H)58
SPW-W…H(H)8
128
9,17
15
Sound testing conditions: 1 m in front at height of 1.5 m
Accessories
Product Code
70600054
70600055
70600027
70250065
70600118
70600218
70600123
70600124
70600125
70600114
70600119
RCS-TM80BG
Type of Application
1 zone terminal unit



Remarks
1 zone floor



2 zone floor





Mixed 2 zone

















1 zone radiator











2 flexible water pipes set (Ø3/4”, 1m)
2 flexible water pipes set (Ø1”, 1m)
2 flexible water pipes set (Ø1-1/4”, 1m)
Room temperature sensor (additional)
Combination dual-zone module (M2Z P)
Combination dual-zone module (M2Z M)
Buffer tank 35 Lit. (6 ports)
Buffer tank 70 Lit. (6 ports)
Water flow adjustment valve 10~40 L/min
Water flow adjustment valve 20~70 L/min
Water flow adjustment valve 30~120 L/min
Strainer Ø1”
Strainer Ø1-1/4”
Remote controller (for service work)
 Neccesary  May use by neccesity
49
Elite PACi
Classic PACi
Elite PACi
for high efficiency
and top performance
Classic PACi
for economy
and value
The great designed and engineered Elite PACi
is one of the top performers of its type in the
industry. Especially designed for light commercial
projects where efficiency and performance
must not be compromised, the Elite PACi boasts
many advanced features. SANYO’s DC inverter
technology offers outstanding heating and
cooling power with quieter operation and
energy-saving.
SANYO’s Classic PACi is the perfect solution
for projects which demand quality on a
limited budget. With high quality design
and engineering, the Classic PACi offers
reliability and robust operation. In addition, its
compact size and light weight make it ideal for
installations with limited space including small
commercial and residential applications.
SPW-C...VEH
• N
ewly designed heat exchanger and outdoor fan means that
COP ratings are some of the highest in the industry
Quick start up - takes half the time to reach cool or
warm air
• Piping length has been increased by 40% to 70m
SANYO DC inverter technology has efficient rapid heating
and cooling capacity which is produced by variable compressor
rotation speed; it ensures quicker control of room temperature
than conventional air conditioners.
• R
educed refrigerant charge to help comply with
F-Gas regulations
• N
ow operates at temperatures as low as -20°C in heating and
cooling mode
• Compact and lightweight design for ease of installation
• Very quiet operation with sounds levels from just 53 dB(A)
• Ideal for enhancing the air quality in shops, restaurants and
other businesses
mm
kg
W
db(A)
m
mm (in)
mm
kg
W
db(A)
m
mm (in)
• Operates at temperatures as low as -15˚C in heating mode
• Quality design and engineering
• Compact size saving valuable footprint
• Lightweight
• Great value and reliability at a low capital cost
• Available in four sizes (3, 4, 5 and 6 HP)
• Available in both single and three phase
• Up to 4 indoor units can be fitted on multi-split systems
3
25
SPW-C256VEH
780x940x340
54
1950/2150
46/48
50
9,52(3/8)/15,88(5/8)
SPW-C256VEH8
780x940x340
65
2090/2140
51/52
50
9,52(3/8)/15,88(5/8)
4
36
SPW-C366VEHN
1130x940x410
90
2500/2800
52/53
70
9,52(3/8)/15,88(5/8)
SPW-C366VEH8
1130x940x410
95
2480/2800
48/49
70
9,52(3/8)/15,88(5/8)
5
48
SPW-C486VEHN
1130x940x410
95
3570/3660
53/54
70
9,52(3/8)/15,88(5/8)
SPW-C486VEH8
1130x940x410
96
3570/3660
49/50
70
9,52(3/8)/15,88(5/8)
6
60
SPW-C606VEHN
1130x940x410
95
4370/4430
54/56
70
9,52(3/8)/15,88(5/8)
SPW-C606VEH8
1130x940x410
96
4310/4430
49/51
70
9,52(3/8)/15,88(5/8)
Specifications subject to change without notice.
The table lists the X type of indoor units as representative models. For details on the connection of indoor units other than the X type, refer to the technical data
50
• SANYO DC inverter compressor
• Ideal for small commercial and residential applications
• N
ow 8 different styles of indoor units to provide more
flexibility for different applications
2
18
SPW-C186VEH
569x790x285
41
1290/1430
46/47
40
6,35(1/4)/12,7(1/2)
-
• N
ow 8 different styles of indoor units to provide more
flexibility for different applications
• Pipe runs up to 50m
• Up to 4 indoor units can be fitted on multi-split systems
Elite line up
HP
Class
1phase model (220-240V,50/60Hz)
Dimension
(HxLxD)
Net weight
Power Input
(Cool/Heat)
Sound pressure level (H)(Cool/Heat)
Max. piping length
Tube diameter
3phase model (380-415V; 50Hz)
Dimension
(HxLxD)
Net weight
Power Input
(Cool/Heat)
Sound pressure level (H)(Cool/Heat)
Max. piping length
Tube diameter
• New single fan design
SPW-C...VH
• Low start current
High efficiency
Elite PACi uses a twin rotary compressor. The dual rotors
revolve smoothly in a well-balanced fashion for stable and
efficient performance. This contributes to increased comfort
and rapid heating and cooling as well as ultra‑quiet operation.
• Available in single phase and three phase
Commercial Split-Systems (PACi)
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Classic line up
HP
Class
1phase model (220-240V,50/60Hz)
Dimension (HxLxD)
Net weight
Power Input (Cool/Heat)
Sound pressure level (H) (Cool/Heat)
Max. piping length
Tube diameter
3phase model (380-415V; 50Hz)
Dimension (HxLxD)
Net weight
Power Input (Cool/Heat)
Sound pressure level (H) (Cool/Heat)
Max. piping length
Tube diameter
mm
kg
W
db(A)
m
mm (in)
mm
kg
W
db(A)
m
mm (in)
3
25
SPW-C256VH
569x790x285
41
2190/2340
49/51
50
9,52(3/8)/15,88(5/8)
SPW-C256VH8
780x940x340
58
2380/2290
47/49
50
9,52(3/8)/15,88(5/8)
4
36
SPW-C366VH
780x940x340
58
3400/3390
50/52
50
9,52(3/8)/15,88(5/8)
SPW-C366VH8
780x940x340
65
3800/3310
51/52
50
9,52(3/8)/15,88(5/8)
5
48
SPW-C486VH
910x940x340
71
4450/4220
51/54
50
9,52(3/8)/15,88(5/8)
SPW-C486VH8
910x940x340
76
4450/4220
51/54
50
9,52(3/8)/15,88(5/8)
6
60
SPW-C606VH8
910x940x340
76
5430/4520
52/55
50
9,52(3/8)/15,88(5/8)
Specifications subject to change without notice.
The table lists the X type of indoor units as representative models. For details on the connection of indoor units other than the X type, refer to the technical data
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
51
KR type
wall mounted
Commercial Split-Systems (PACi)
SPW-KR...GH56B
Controller Options
Timer remote controller
Wireless remote controller
Simplified remote controller
RCS-TM80BG
RCS-SH1BG
RCS-KR1EG
The slimline designed KR type wall mounted unit
is small and light, making it ideal for commercial
applications. It is also available in a wide variety of
capacities.
SPW-KR...GH56B
• Simple, versatile design with anti‑mould filters as standard
RCS-BH80BG.WL
Washable front panel
• T win rotary compressor dramatically reduces vibration and
noise during operation
The indoor unit’s front panel can be easily removed and washed
for trouble-free cleaning.
• Cooling and heating operation down to -15°C
• Low operating sound levels from 32 dB(A)
• Single phase electrical supplier
Outdoor
• M
ultifunctional wireless remote control with built-in
temperature control
• Twin, triple and quadruple split options
Elite
Inverter Heat Pump
Performance
Capacity
Power input
1ph/3ph
EER/COP
1ph/3ph
Energy class
1ph/3ph
Running amperes
1ph/3ph
Annual energy consumption (cooling) 1ph/3ph
Indoor Unit
Air-circulation (H/M/L)
Moister removal
Sound Pressure Level (H/M/L)
Dimensions HxWxD
Net weight
Power supply
Outdoor Unit 1ph/3ph
Sound Pressure Level (H)
Dimensions H/W/D
Net weight
1ph/3ph
Power supply
Refrigerant circuit
Tube diameter Narrow/Wide
Max piping lenght
Max elevation difference - O.U. above/below I.U.
Chargeless piping lenght
Amount of additional refrigerant
size 186
kW
W
A
kWh
m3/h
Liters/h
dB-A
mm
kg
V, ph, Hz
size 256
Cooling
Heating
1,5/5,0/5,6
1,5/5,6/6,3
1560/1730/3,21/3,24/A/C/7,80/8,65/780/-/SPW-KR184GH56B
780/660/480
2,1
38/34/30
285x995x203
12
SPW-C186VEH / -
dB-A
mm
kg
V, ph, Hz
mm(in)
m
m
m
g/m
46
47
569x790x285
41/220-240,1,50/60
size 186
6,35 (1/4) / 12,7 (1/2)
40
30 / 15
30
20
Cooling
Heating
2,2/7,1/8,0
2,2/8,0/9,0
2210/2360
2450/2430
3,21/3,01
3,27/3,29
A/C/11,0/na
12,4/na
1105/1180
-/SPW-KR254GH56B
1140/960/720
4,0
41/37/34
330x1140x228
21
220-240,1,50/60
SPW-C256VEH / SPW-C256VEH8
46
48
780x940x340
54/65
220-240,1,50/60 / 380-415,3+N,50
size 256
9,52 (3/8) / 15,88 (5/8)
50
30 / 15
30
40
Classic
Inverter Heat Pump
Performance
Capacity
Power input
1ph/3ph
EER/COP
1ph/3ph
Energy class
1ph/3ph
Running amperes
1ph/3ph
Annual energy consumption (cooling) 1ph/3ph
Indoor Unit
Air-circulation (H/M/L)
Moister removal
Sound Pressure Level (H/M/L)
Dimensions HxWxD
Net weight
Power supply
Outdoor Unit 1ph/3ph
Sound Pressure Level (H)
Dimensions H/W/D
Net weight 1ph/3ph
Power supply
Refrigerant circuit
Tube diameter Narrow/Wide
Max piping lenght
Max elevation difference - O.U. above/below I.U.
Chargeless piping lenght
Amount of additional refrigerant
Indoor
43°C DB
32°C DB
15°C WB
-15°C DB
18°C DB
-20°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Indoor
30°C DB
size 256
kW
W
A
kWh
m3/h
Liters/h
dB-A
mm
kg
V, ph, Hz
dB-A
mm
kg
V, ph, Hz
mm(in)
m
m
m
g/m
Cooling
2,2/7,1/8,0
2580/2800
2,75/2,54
D/12,9/na
1290/1400
Heating
2,2/8,0/9,0
2750/2600
2,91/3,08
-/13,7/na
-/SPW-KR254GH56B
1140/960/720
4,0
41/37/34
330/1140/228
21
220-240,1,50/60
SPW-C256VH / SPW-C256VH8
49
51
569x790x285 / 780x940x340
41/58
220-240,1,50/60 / 380-415/3+N,50
size 256
9,52(3/8) / 15,88(5/8)
50
30/15
20
40
Specifications subject to change without notice.
na: at time of publication not available
Specifications subject to change without notice.
na: at time of publication not available
52
Outdoor
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
53
T type
ceiling mounted
Commercial Split-Systems (PACi)
SPW-T...H
Controller Options
Timer remote controller
Wireless remote controller
(Transmitter, common part)
The range of ceiling mounted units feature a DC
fan motor for increased efficiency and reduced
operating sound levels. All the units are the
same height and depth for a uniform appearance
in mixed installations and feature a fresh air
knockout for improved air quality.
RCS-TRP80BG.WL
RCS-TM80BG
SPW-T...H
• All units just 210mm high
• T win rotary compressor dramatically reduces vibration
and noise during operation
Air distribution is automatically altered depending on the
operational mode of the unit.
F2
• Large and wide air distribution
• SANYO DC fan motor for increased efficiency
Further comfort improvement with airflow distribution.
60°
F3
Heating: F1 to F3
F4
F5
• Industry low sound levels
Outdoor
Cooling: F1 to F3
• Twin, triple and quadruple split options
Elite
Indoor
Outdoor
Indoor
43°C DB
32°C DB
15°C WB
-15°C DB
18°C DB
-20°C WB
30°C DB
Classic
kW
W
A
kWh
m3/h
Litres/h
dB(A)
mm
kg
V, ph, Hz
dB(A)
mm
kg
V, ph, Hz
mm (in)
m
m
m
g/m
size 186
size 256
size 366
size 486
size 606
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
1,5/5,0/5,6 1,5/5,6/6,3 2,2/7,1/8,0 2,2/8,0/9,0 2,2/10,0/12,5 2,2/11,2/12,5 2,7/12,5/14,0 2,7/14,0/17,5 2,7/14,0/15,0 2,7/16,0/18,5
1450/1790/2200/2360 2570/2560 2750/2730 2870/2880 3710/3710 3880/3940 4950/4880 4840/4720
3,45/3,13/3,23/3,01 3,11/3,13
3,64/3,66
3,90/3,89
3,37/3,37 3,61/3,55 2,83/2,87 3,31/3,39
7,33
9,05
11,1/na
13,1/na
13,1/na
13,6/na
19,1/na
18,8/na
25,3/na
24,7/na
725/-/1100/1180
-/1375/1365
-/-/-/-/-/SPW-T185H
SPW-T255H
SPW-T365H
SPW-T485H
SPW-T605H
780/660/540
1100/900/840
1650/1380/1200
1800/1560/1320
1800/1560/1320
2,0
3,0
3,9
5,6
5,6
36/33/30
38/36/33
41/38/35
43/40/37
43/40/37
210x910x680
210x1180x680
210/1595/680
210/1595/680
210/1595/680
21
25
33
33
33
220-240, 1, 50/60
SPW-C186VEH/SPW-256VEH/ SPW-256VEH8
SPW-C366VEH/ SPW-C366VEH8
SPW-C486VEH/ SPW-C486VEH8
SPW-C606VEH/ SPW-C606VEH8
46/47/46/51
48/52
52/48
53/49
53/49
54/50
54/49
56/51
569x790x285
780x940x340
780x940x410
780x940x410
780x940x410
41/54/65
90/95
90/96
90/96
220-240, 1, 50/60 / 380-415, 3+N, 50
size 186
size 256
size 366
size 486
size 606
6,35(1/4)/ 12,7(1/2)
9,52(3/8)/ 15,88(5/8)
9,52(3/8)/ 15,88(5/8)
9,52(3/8)/ 15,88(5/8)
9,52(3/8)/ 15,88(5/8)
40
50
70
70
70
30 / 15
30 / 15
30 / 15
30 / 15
30 / 15
30
30
30
30
30
20
40
40
40
40
Specifications subject to change without notice.
na: not available at time of publication
54
RCS-KR1EG
RCS-BH80BG.WL
F1
• DC inverter control
Performance
Capacity
Power input
1ph/3ph
EER/COP
1ph/3ph
Running amperes
1ph/3ph
Annual energy consumption (cooling)1ph/3ph
Indoor Unit
Air-circulation
(H/M/L)
Moisture removal
Sound pressure level
(H/M/L)
Dimensions
(HxWxD)
Net weight
Power supply
Outdoor Unit
1ph/3ph
Sound pressure level
1ph/3ph (H)
Dimensions
(H/W/D)
Net weight
1ph/3ph
Power supply
Refrigerant Circuit
Tube diameter
narrow/wide
Max piping length
Max elevation difference - O.U. above/below I.U.
Chargeless piping length
Amount of additional refrigerant
Simplified remote controller
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Performance
Capacity
kW
Power input
1ph/ 3ph
W
EER/COP
1ph/ 3ph
Energy class
1ph/ 3ph
Running amperes
1ph/ 3ph
A
Annual energy consumption (cooling) 1ph/ 3ph
kWh
Indoor Unit
Air-circulation
(H/M/L)
m3/h
Moisture removal
Litres/h
Sound pressure level
(H/M/L)
dB(A)
Dimensions
(HxWxD)
mm
Net weight
kg
V, ph, Hz
Power supply
Outdoor Unit
1ph/ 3ph
Sound pressure level
(H) 1ph/ 3ph
dB(A)
Dimensions
(H/W/D)
mm
Net weight
1ph/ 3ph
kg
V, ph, Hz
Power supply
Refrigerant Circuit
Tube diameter
narrow/wide Inches
Max piping length
m
Max elevation difference - O.U. above/below I.U.
m
Chargeless piping length
m
Amount of additional refrigerant
g/m
size 256
Cooling
Heating
2,2/7,1/8,0
2,2/8,0/9,0
2600/2830
2740/2690
2,73/2,51
2,92/2,97
D/E
D/D
13,1/na
13,9/na
1300/1415
-/SPW-T255H
1100/900/840
3,0
38/36/33
210x1180x680
25
SPW-C256VH/ SPW-C256VH8
49/47 / 51/49
569x790x285
41/58
size 256
9,52(3/8)/ 15,88(5/8)
50
30 / 15
20
40
size 366
size 486
Cooling
Heating
Cooling
Heating
2,2/10,0/11,2 2,2/11,2/12,5 2,7/12,5/13,4 2,7/14,0/16,0
4200/4700
3570/3480
5310/5440
4460/4420
2,38/2,13
3,14/3,22
2,35/2,30
3,14/3,17
-/D/C
-/-/21,2/na
18,0/na
26,8/na
22,5/na
2100/2350
-/-/-/SPW-T365H
SPW-T485H
1650/1380/1200
1800/1560/1320
3,9
5,6
41/38/35
43/40/37
210/1595/680
210/1595/680
33
33
220-240, 1, 50/60
SPW-C366VH/ SPW-C366VH8
SPW-C486VH/ SPW-C486VH8
50/51 / 52/52
51/51 / 54/54
780x940x340
910x940x340
58/65
71/76
220-240, 1, 50/60 / 380-415, 3+N, 50
size 366
size 486
9,52(3/8)/ 15,88(5/8)
9,52(3/8)/ 15,88(5/8)
50
50
30 / 15
30 / 15
30
30
40
40
size 606
Cooling
Heating
14,0
15,0
-/6490
-/4730
2,16
3,17
-/-/-/na
-/na
SPW-T605H
1800/1560/1320
na
43/40/37
210/1595/680
33
-/SPW-C606VH
-/52 / -/55
910x940x340
71/76
size 606
9,52(3/8)/ 15,88(5/8)
50
30 / 15
30
40
Specifications subject to change without notice.
na: not available at time of publication
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
55
X type
semi concealed
Commercial Split-Systems (PACi)
SPW-X...H
Controller Options
Panel
Air intake chamber
Timer remote controller
The award winning range of X type cassettes are
smaller, shallower and lighter than previous models
and feature a 950 x 950mm panel throughout. The
DC fan motor and new air discharge louvre ensure
quiet, optimum air distribution.
Wireless remote controller Simplified remote controller
(Transmitter, common part)
RCS-SH80BG.WL
SPW-X...H
PNR-XD484GHAB
Air intake box
CMB-GS140AGB
RCS-TM80BG
RCS-KR1EG
RCS-BH80BG.WL
Air intake plenum
CMB-FS140AGB
• New compact design
oth Air intake plenum and
B
Air intake box are necessary
Easy installation
• T win rotary compressor dramatically reduces vibration and
noise during operation
• Reduced sound levels
• DC fan motor for increased efficiency
Outdoor
• Powerful drain pump gives 850mm lift
• Fresh air knockout for improved air quality
• Twin, triple and quadruple split options
Elite
Performance
Capacity
Power input
1ph/ 3ph
EER/COP
1ph/ 3ph
Energy class
1ph/ 3ph
Running amperes
1ph/ 3ph
Annual energy consumption (cooling)1ph/ 3ph
Indoor Unit
Air-circulation
(H/M/L)
Moisture removal
Sound pressure level
(H/M/L)
Dimensions
(HxWxD)
Dimensions Panel
(HxWxD)
Net weight
Panel weight
Power supply
Outdoor Unit
1ph/ 3ph
Sound pressure level
1ph/ 3ph (H)
Dimensions
(H/W/D)
Net weight
1ph/ 3ph
Power supply
Refrigerant Circuit
Tube diameter
narrow/wide
Max piping length
Max elevation difference - O.U. above/below I.U.
Chargeless piping length
Amount of additional refrigerant
Outdoor
Indoor
43°C DB
32°C DB
15°C WB
-15°C DB
18°C DB
-20°C WB
30°C DB
Classic
kW
W
A
kWh
m3/h
Litres/h
dB(A)
mm
mm
kg
kg
V, ph, Hz
dB(A)
mm
kg
V, ph, Hz
mm (in)
m
m
m
g/m
size 186
size 256
size 366
size 486
size 606
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
1,5/5,0/5,6 1,5/5,6/6,3 2,2/7,1/8,0 2,2/8,0/9,0 2,2/10,0/11,2 2,7/11,2/14,5 2,7/12,5/14,0 2,7/14,0/17,5 2,7/14,0/15,0 2,7/16,0/18,5
1290/1430/1950/2090 2150/2140 2500/2480 2800/2800 3570/3570 3660/3660 4370/4310 4540/4430
3,88
3,92
3,64
3,72
4,00
4,00
3,50
3,83
3,20
3,52
A/A/A/A
A/A
A/A
A/A
-/-/-/-/6,52/7,22/9,80/3,43 10,9/3,51 11,9/4,07 13,3/4,61 17,4/5,86 17,7/6,11 22,3/7,08 23,2/7,27
645/975/1045
1250/1240
SPW-X185H
SPW-X255H
SPW-X365H
SPW-X485H
SPW-X605H
960/840/780
1200/960/840
1680/1380/1260
1980/1500/1320
2040/1620/1380
2,2
2,8
3,9
4,6
4,8
31/29/27
34/31/28
39/36/33
42/38/34
44/40/36
256x840x840
256x840x840
319/840/840
319/840/840
319/840/840
35x950x950
35x950x950
35x950x950
35x950x950
35x950x950
21
21
26
26
26
4,5
4,5
4,5
4,5
4,5
220-240, 1, 50/60
SPW-C186VEH/SPW-C256VEH / SPW-C256VEH8
SPW-C366VEHN / SPW-C366VEH8
SPW-C486VEHN / SPW-C486VEH8
SPW-C606VEHN / SPW-C606VEH8
46/47/46/51
48/52
52/48
53/49
53/49
54/50
54/50
56/51
569x790x285
780x940x340
1330x940x410
1330x940x410
1330x940x410
41/54/65
90/95
95/96
95/96
220-240, 1, 50/60
220-240, 1, 50/60 / 315-400, 3 + N, 50
size 186
size 256
size 366
size 486
size 606
6,35(1/4)/ 12,7(1/2)
9,52(3/8)/ 15,88(5/8)
9,52(3/8)/ 15,88(5/8)
9,52(3/8)/ 15,88(5/8)
9,52(3/8)/ 15,88(5/8)
40
50
70
70
70
30 / 15
30 / 15
30 / 15
30 / 15
30 / 15
30
30
30
30
30
20
40
40
40
40
Specifications subject to change without notice. na: not available at time of publication.
56
Indoor
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Performance
Capacity
Power input
1ph/ 3ph
EER/COP
1ph/ 3ph
Energy class
1ph/ 3ph
Running amperes
1ph/ 3ph
Annual energy consumption (cooling) 1ph/ 3ph
Indoor Unit
Air-circulation
(H/M/L)
Moisture removal
Sound pressure level
(H/M/L)
Dimensions
(HxWxD)
Dimensions Panel
(HxWxD)
Net weight
Panel weight
Power supply
Outdoor Unit
1ph/ 3ph
Sound pressure level
1ph/ 3ph (H)
Dimensions
(H/W/D)
Net weight
1ph/ 3ph
Power supply
Refrigerant Circuit
Tube diameter
narrow/wide
Max piping length
Max elevation difference - O.U. above/below I.U.
Chargeless piping length
Amount of additional refrigerant
kW
W
A
kWh
m3/h
Litres/h
dB(A)
mm
mm
kg
kg
V, ph, Hz
dB(A)
mm
kg
V, ph, Hz
mm(in)
m
m
m
g/m
size 256
Cooling
Heating
2,2/7,1/8,0
2,2/8,0/9,0
2190/2380
23402290
3,24/2,98
3,42/2,94
A/C
B/B
11,1/3,91
11,8/3,76
1095/1190
SPW-X255H
1200/960/840
2,8
34/31/28
256x840x840
35x950x950
22
4,5
size 366
size 486
Cooling
Heating
Cooling
Heating
2,2/10,0/11,2 2,2/11,2/12,5 2,7/12,5/14,0 2,7/14,0/16,0
3400/3800
3390/3310
4450/4450
4220/4220
3,94/2,63
3,30/3,38
2,81/2,81
3,32/3,32
C/B
C/C
-/-/17,2/6,24
17,1/5,44
22,5/7,31
21,3/6,93
1700/1900
SPW-X365H
SPW-X485H
1680/1380/1260
1980/1500/1320
3,9
4,6
39/36/33
42/38/34
319x840x840
319x840x840
35x950x950
35x950x950
26
26
4,5
4,5
220-240, 1, 50/60
SPW-C256VH / SPW-C256VH8
SPW-C366VH / SPW-C366VH8
SPW-C486VH / SPW-C486VH
49/47 / 51/49
50/51 / 51/52
51/51 / 54/54
569x790x285 / 780x940x340
780x940x340
910x940x340
41 / 58
58 / 65
71 / 76
220-240, 1, 50/60 / 315-400, 3 + N, 50
size 256
size 366
size 486
9,52(3/8) / 15,88(5/8)
9,52(3/8) / 15,88(5/8)
9,52(3/8) / 15,88(5/8)
50
50
50
30 / 15
30 / 15
30 / 15
20
30
30
40
40
40
size 606
Cooling
Heating
14,0
15,0
-/5430
-/4520
-/2,58
-/3,22
-/-/-/8,92
-/3,32
SPW-X606H
2040/1640/1380
4,8
44/40/36
319x840x840
35x950x950
26
4,5
-/ SPW-C606VH8
-/52 / -/55
910x940x340
- / 76
size 606
9,52(3/8) / 15,88(5/8)
50
30 / 15
30
40
Specifications subject to change without notice. na: not available at time of publication.
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
57
XM type
mini semi concealed
XMR type
mini semi concealed
SPW-XM...H
SPW-XMR...EH56B
Panel
Panel
Designed to fit exactly into a 600x600mm
ceiling grid without the need to alter the
bar configuration, the XM is ideal for small
commercial and retro
fit applications.
In addition, the improvements to efficiency
make this one of the most advanced units in
the industry.
SPW-XM...H
• Fresh air knock out
Controller Options
• Multidirectional air flow
Timerremotecontroller
• Integrated drain pump gives 250mm lift
Commercial Split-Systems (PACi)
Designed to fit exactly into a 600 x 600mm
ceiling grid without the need to alter the
bar configuration, the XMR is ideal for small
commercial and retro fit applications.
SPW-XMR...EH56B
PNR-XM185
Wireless remote controller Simplified remote controller
(Transmitter, common part)
• New dimensions 600 x 600mm suitable for
European ceiling standards
• Multi-directional air flow
PNR-XM184EHAB
Controller Options
Timer remote controller Wireless remote controller
(Transmitter, common part)
Simplified remote controller
• 3-speed centrifugal fan
• 3 speed centrifugal fan
• Fresh air knockout
• Anti-mould and anti-bacteria washable filters
RCS-SS80BG.WL
• Anti-mould and anti-bacteria washable filters
• Low operating sound
Lighter and slimmer, easier installation
RCS-TM80BG
RCS-XM18BG.WL
RCS-KR1EG
• Integral drain pump gives 250mm lift
Height 281 mm
A drain height of approx. 850 mm from the ceiling surface
The drain height can be increased by approx. 350 mm over the
conventional value by using a high-lift drain pump, and long
horizontal piping is possible.
Up to 300 mm
Up to 850 mm
Significant reduction of power consumption by using
highly developed DC fan motors with variable speed,
special heat exchangers, etc.
Convenient cleaning
The flap can be
removedeasilyfor
washing.
58
Elite
Inverter Heat Pump
size 186
Performance
Cooling
Heating
Capacity
kW
1,5/5,0/5,6
1,5/5,6/6,3
Power input
W
1390
1490
EER/COP
3,60
3,76
Energy class
A
A
Running amperes
A
7,03
7,53
Annual Energy consumption (cooling)
kWh
695
Indoor Unit
SPW-XM185H
Air-circulation (H/M/L)
m3/h
750/630/540
Moister removal
Liters/h
1,9
Sound Pressure Level (H/M/L)
dB-A
41/37/33
Dimensions HxWxD (Unit)
mm
283x575x575
Dimensions HxWxD (Panel)
mm
30x625x625
Net weight (Unit)
kg
16
Net weight (Panel)
kg
2,4
V, ph, Hz
220-240,1,50/60
Power supply
Outdoor Unit
SPW-C186VEH
Sound Pressure Level (H)
dB-A
46
47
Dimensions H/W/D
mm
569/790/285
Net weight
kg
41
Power supply
V, ph, Hz
220-240,1,50/60
Refrigerant circuit
size 186
Tube diameter Narrow/Wide
mm(in)
6,35(1/4)/12,7(1/2)
Max piping length
m
40
Max elevation difference - O.U. above/below I.U.
m
30/15
Chargeless piping lenght
m
30
Amount of additional refrigerant
g/m
20
Specifications subject to change without notice.
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
RCS-BH80BG.WL
RCS-TM80BG
Lightweight and very slim with makes installation possible
even in narrow ceilings.
Elite
Inverter Heat Pump
size 186
Performance
Cooling
Heating
Capacity
kW
1,5/5,0/5,6
1,5/5,6/6,3
Power input
W
1590
1760
EER/COP
3,14
3,18
Energy class
B
Running amperes
A
7,9
8,8
Annual Energy consumption (cooling)
kWh
795
Indoor Unit
SPW-XMR184EH56B
Air-circulation (H/M/L)
m3/h
750/630/530
Moister removal
Liters/h
2,0
Sound Pressure Level (H/M/L)
dB-A
44/40/37
Dimensions HxWxD (Unit)
mm
296x575x575
Dimensions HxWxD (Panel)
mm
41x730x730
Net weight (Unit)
kg
18
Net weight (Panel)
kg
2,5
V, ph, Hz
220-240,1,50/60
Power supply
Outdoor Unit
SPW-C186VEH
Sound Pressure Level (H)
dB-A
46
47
Dimensions H/W/D
mm
569/790/285
Net weight
kg
41
Power supply
V, ph, Hz
220-240,1,50/60
Refrigerant circuit
size 186
Tube diameter Narrow/Wide
mm(in)
6,35(1/4)/12,7(1/2)
Max piping length
m
40
Max elevation difference - O.U. above/below I.U.
m
30/15
Chargeless piping lenght
m
30
Amount of additional refrigerant
g/m
20
Specifications subject to change without notice.
Outdoor
Indoor
RCS-KR1EG
Outdoor
43°C DB
32°C DB
15°C WB
-15°C DB
18°C DB
-20°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Indoor
30°C DB
59
US & UMR type
slim concealed duct & concealed duct
FTR type
floor/ceiling mounted
SPW-US...H
SPW-FTR...EH56B
SPW-UMR...EH56B
Commercial Split-Systems (PACi)
Controller Options (US/UMR/FTR type)
Timerremotecontroller
SPW-US...H
SPW-UMR...EH56B
SPW-FTR...EH56B
The depth of only 200mm provides greater flexibility
and can be used in far more applications. Its highefficiency and extremely quiet sound levels make it
ideal for hotels and small offices.
Suitable for areas where there is restricted ceiling
void space and a demand for longer ductwork runs.
The FTR type units offer the flexibility of floor or
ceiling application without the need for further
modification at installation stage.
• Reduced power consumption by 50%
• Maximum depth 266mm
• 3 speed centrifugal fan
• 40pa static pressure
• Boost mode static pressure up to 70 pa
• Anti-mould and anti-bacterial washable filters
• Extremely quiet: 26 dB(A) at low speed (class 7, 9,12)
• Drain pump maximum lift 250mm
• Horizontal flap swinging or set on a fixed position
• Anti‑mould washable filters included
• Anti-mould and anti-bacteria washable filters
• Shallow design
• Easy maintenance and service by an external electrical box
• Fresh air intake
• Easy to install
• 3
speed centrifugal fan through wired or wireless remote
control
• High static option
RCS-TM80BG
Wireless remote controller Simplifiedremotecontroller
RCS-KR1EG
RCS-BH80BG.WL
• DC fan motor reduces power consumption
• Ideal for applications with limited false ceiling space
• Built in drain pump
Elite
Inverter Heat Pump
size 186
Performance
Cooling
Heating
Capacity
kW
1,5/5,0/5,6
1,5/5,6/6,3
Power input
W
1490
1630
EER/COP
3,36
3,44
Energy class
A
B
Running amperes
A
7,62
8,24
Annual energy consumption (cooling)
kWh
745
Indoor Unit
SPW-US185H
750/690/600
Air-circulation
(H/M/L)
m3/h
Moister removal
Liters/h
1,8
Sound Pressure Level
(H/M/L)
dB-A
35/33/31(37/35/33)
Dimensions
HxWxD
mm
200x750x640
Net weight
kg
19
Power supply
V, ph, Hz
220-240,1,50/60
Outdoor Unit
SPW-C186VEH
Sound Pressure Level
(H)
dB-A
46
47
Dimensions
H/W/D
mm
569/790/285
Net weight
kg
40
Power supply
V, ph, Hz
220-240,1,50/60
Refrigerant circuit
size 186
Tube diameter
Narrow/Wide mm(in)
6,35(1/2)/12,7(1/4)
Max piping lenght
m
40
m
30/15
Max elevation difference - O.U. above/below I.U.
Chargeless piping lenght
m
30
Amount of additional refrigerant
g/m
20
Specifications subject to change without notice.
60
Elite
Inverter Heat Pump
size 186
Performance
Cooling
Heating
Capacity
kW
1,5/5,0/5,6
1,5/5,6/6,3
Power input
W
1670
1830
EER/COP
2,99
3,06
Energy class
Cooling
Running amperes
A
8,3
9,0
Annual energy consumption (cooling)
kWh
835
Indoor Unit
SPW-UMR184EH56B
875/600/400
Air-circulation
(H/M/L)
m3/h
Moister removal
Liters/h
2,0
Sound Pressure Level
(H/M/L)
dB-A
45/38/33
Dimensions
HxWxD
mm
266x571x1058
Net weight
kg
35
Power supply
V, ph, Hz
220-240,1,50/60
Outdoor Unit
SPW-C186VEH
Sound Pressure Level
(H)
dB-A
46
47
Dimensions
H/W/D
mm
569/790/285
Net weight
kg
40
Power supply
V, ph, Hz
220-240,1,50/60
Refrigerant circuit
size 186
Tube diameter
Narrow/Wide mm(in)
6,35(1/2)/12,7(1/4)
Max piping lenght
m
40
Max elevation difference - O.U. above/below I.U.
m
30/15
Chargeless piping lenght
m
30
Amount of additional refrigerant
g/m
20
Specifications subject to change without notice.
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Elite
Inverter Heat Pump
size 186
Performance
Cooling
Heating
Capacity
kW
1,5/5,0/5,6
1,5/5,6/6,3
Power input
W
1620
1780
EER/COP
3,09
3,15
Energy class
B
Running amperes
A
8,10
8,90
Annual energy consumption (cooling)
kWh
810
Indoor Unit
SPW-FTR184EH56B
830/760/665
Air-circulation
(H/M/L)
m3/h
Moister removal
Liters/h
2,1
Sound Pressure Level
(H/M/L)
dB-A
52/49/46
Dimensions
HxWxD
mm
680x900x190
Net weight
kg
23,5
Power supply
V, ph, Hz
220-240,1,50/60
Outdoor Unit
SPW-C186VEH
Sound Pressure Level
(H)
dB-A
46
47
Dimensions
H/W/D
mm
569/790/285
Net weight
kg
40
Power supply
V, ph, Hz
220-240,1,50/60
Refrigerant circuit
size 186
Tube diameter
Narrow/Wide mm(in)
6,35(1/2)/12,7(1/4)
Max piping lenght
m
40
Max elevation difference - O.U. above/below I.U.
m
30/15
Chargeless piping lenght
m
30
Amount of additional refrigerant
g/m
20
Specifications subject to change without notice.
Outdoor
Indoor
Outdoor
43°C DB
32°C DB
15°C WB
-15°C DB
18°C DB
-20°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Indoor
30°C DB
61
U type
concealed duct
Commercial Split-Systems (PACi)
SPW-U...H
Controller Options
Timer remote controller
Wireless remote controller
Simplified remote controller
The U type ducted systems are the ideal
solution for flexible, concealed air conditioning
and the standard 200mm spigots ensure simple,
hassle‑free connection to flexible ductwork.
RCS-TM80BG
SPW-U...H
• Extremely quiet operation from 25dB(A)
External electrical equipment box makes maintenance easy
Comfortable space by using flexible air distribution ducts
• Auto restart after power failure
RCS-KR1EG
RCS-BH80BG.WL
Unified body height of approximately 310 mm for all models.
Even models with different capacities can be installed smoothly
in the ceiling.
• Auto changeover
• Twin, triple and quadruple split options
The external static pressure can be increased by using the
booster cable
Type
Standard
With booster cable
(Pa)
12
49
69
Elite
Inverter Heat Pump
Performance
Capacity
Power input
1ph/3ph
EER/COP
1ph/3ph
Energy class
1ph/3ph
Running amperes
1ph/3ph
Annual energy consumption (cooling)1ph/3ph
Indoor Unit
Air-circulation
(H/M/L)
Moister removal
External Static Pressure (booster)
Sound Pressure Level (H/M/L) (booster)
Dimensions
HxWxD
Net weight
Power supply
Outdoor Unit 1ph/3ph
Sound Pressure Level (H)
1ph/3ph
Dimensions
H/W/D
Net weight
1ph/3ph
Power supply
Refrigerant circuit
Tube diameter
Narrow/Wide
Max piping lenght
Max elevation difference - O.U. above/below I.U.
Chargeless piping lenght
Amount of additional refrigerant
16,18
40
62
25
50
92
kW
W
A
kWh
m3/h
Liters/h
Pa
dB-A
mm
kg
V, ph, Hz
dB-A
mm
kg
V, ph, Hz
mm(in)
m
m
m
g/m
36
79
122
The built-in drain pump has an improved lift of 785mm.
Outdoor
48,60
78
113
size 186
size 256
size 366
size 486
size 606
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
1,5/5,0/5,6 1,5/5,6/6,3 2,2/7,1/8,0 2,2/8,0/9,0 2,2/10,0/11,2 2,2/11,2/14,5 2,7/12,5/14,0 2,7/14,0/17,5 2,7/14,0/15,0 2,7/16,0/18,5
1610/1740/2450/2600 2560/2530 2890/2850 3070/3060 4100/4080 4130/4150 4960/4880 5080/4940
3,11/3,22/2,90/2,73 3,13/3,16 3,46/3,51 3,65/3,66 3,05/3,06 3,39/3,37 2,82/2,87
3,153,24
B/C/C/-/A/A
A/A
-/-/-/-/7,95/8,6/12,1/na
12,8/na
13,5/na
14,3/na
19,2/na
19,7/na
24,9/na
25,5/na
805/-/1225/1300
-/1445/1425
-/-/-/-/-/SPW-U185H
SPW-U255H
SPW-U365H
SPW-U485H
SPW-U605H
720/630/540
1080/900/780
1800/1560/1260
1980/1800/1500
1980/1800/1501
3,0
3,5
4,2
6,6
6,6
40 (62)
50 (92)
79 (122)
78 (113)
78 (113)
30/28/25 (33/30/28)
34/30/27 (38/34/30)
38/33/31(42/38/33)
40/37/33 (44/40/37)
40/37/33 (44/40/37)
310x700x630
310x1000x630
310x1480x630
310x1480x630
310x1480x630
25
32
47
47
47
220-240, 1, 50/60
SPW-C186VEH/SPW-C256VEH/ VEH8
SPW-C366VEH/ VEH8
SPW-C486VEH/ VEH8
SPW-C606VEH/ VEH8
46/47/46/51
48/52
52/48
53/49
53/50
54/51
54/49
56/51
569/790/285
780x940x340
1330x940x340
1330x940x340
1330x940x340
41/54/65
90/95
95/96
95/96
220-240,1, 50/60
220-240,1, 50/60 / 380-415, 3+N, 50
size 186
size 256
size 366
size 486
size 606
6,35(1/2)/12,7(1/4)
9,52(3/8)/15,88(5/8)
9,52 (3/8) / 15,88 (5/8) 9,52 (3/8) / 15,88 (5/8)
9,52 (3/8) / 15,88 (5/8)
40
50
70
70
70
30/15
30/15
30/15
30/15
30/15
30
30
30
30
30
20
40
40
40
40
Classic
Inverter Heat Pump
Performance
Capacity
kW
Power input
1ph/3ph
W
EER/COP
1ph/3ph
Energy class
1ph/3ph
Running amperes
1ph/3ph
A
Indoor Unit
Air-circulation
(H/M/L)
m3/h
Moister removal
Liters/h
External Static Pressure (booster)
Pa
Sound Pressure Level (H/M/L) (booster)
dB-A
Dimensions
HxWxD
mm
Net weight
kg
Power supply
V, ph, Hz
Outdoor Unit 1ph/3ph
Sound Pressure Level (H)
1ph/3ph
dB-A
Dimensions
H/W/D
mm
Net weight
1ph/3ph
kg
Power supply
V, ph, Hz
Refrigerant circuit
Tube diameter
Narrow/Wide mm(in)
Max piping lenght
m
Max elevation difference - O.U. above/below I.U.
m
Chargeless piping lenght
m
Amount of additional refrigerant
g/m
size 256
Cooling
Heating
2,2/7,1/8,0
2,2/8,0/9,0
2900/3130
2770/2700
2,45/2,27
2,89/,96
C/na
C/na
14,5/na
13,7/na
SPW-U255H
1080/900/780
3,5
50 (92)
34/30/27 (38/34/30)
310x1000x630
32
SPW-C256VH/ VH8
49/47
51/49
569x790x285
41/58
size 256
9,52(3/8) / 15,88(5/8)
50
30/15
20
40
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Outdoor
Indoor
43°C DB
32°C DB
15°C WB
-15°C DB
18°C DB
-20°C WB
size 336
size 486
Cooling
Heating
Cooling
Heating
2,2/10,0/11,2 2,2/11,2/12,5 2,7/12,5/13,4 2,7/14,0/16,0
4120/4570
3930/3880
5160/5430
4850/4790
2,43/2,19
2,81/2,89
2,42/2,30
2,89/2,92
C/na
C/na
-/-/20,47na
19,7/na
25,57na
24,0/na
SPW-U365H
SPW-U485H
1800/1560/1260
1980/1800/1500
4,2
6,6
79 (122)
78 (113)
38/33/31 (42/38/33)
40/37/33 (44/40/37)
310x1480x630
310x1480x630
47
47
220-240,1,50/60
SPW-C366VH/ VH8
SPW-C486VH/ VH8
50/51
52/52
51/51
54/54
780x940x340
910x940x340
58/65
71/76
220-240,1,50/60 / 380-415/3+N,50
size 366
size 486
9,52(3/8) / 15,88 (5,8)
9,52(3/8) / 15,88 (5,8)
50
50
30 / 15
30 / 15
30
30
40
40
Specifications subject to change without notice.
na: at time of publication not available
62
Indoor
30°C DB
size 606
Cooling
Heating
14,0
15,0
-/6220
-/5170
-/2,25
-/2,90
-/-/-/na
-/na
SPW-U605H
1980/1800/1500
na
78 (113)
45/42/38 (44/40/37)
310x1480x630
47
-/SPW-C606VH8
-/52
-/55
910x940x340
-/76
size 606
9,52 (3/8) / 15,88 (5/8)
50
30/15
30
40
Specifications subject to change without notice.
na: at time of publication not available
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
63
Big PACi
D type
SPW-C...VH8
SPW-D...H
Powerful performance in a compact space
SANYO’s Big PACi breaks new ground in offering
high-performance and power in a small space. The
Big PACi is ideally suited for large retail applications
and other large areas not needing the higher
capacities of VRF systems. The new lightweight
and compact design enables easier installation in
any commercial space. The twin fan system saves
valuable footprint compared to traditional 8-10HP
systems which have a larger footprint design.
D type high static pressure concealed duct
The D type high static ducted units are the ideal
solution for flexible, concealed air conditioning
of large areas such as retail and entertainment
projects.
Commercial Split-Systems (PACi)
SPW-D...H
SPW-C...VH8
The high capacity range of condensing units utilises highly
efficient twin scroll compressors and R410A refrigerant. The
outdoor unit can be mounted up to 100 metres away from its
associated indoor unit. The result is a very flexible cooling and
heating solution for large commercial applications. The outdoor
units are capable of providing heating and cooling down to
-15°C, ensuring a comfortable environment all year round, and
each can be matched with a single ducted unit or up to four
indoor units of the same type.
• High capacity 8-10 HP
• High static pressure available for optimum air distribution
• M
aximum pipe length 100m (more than 40% longer than
other split systems)
• Low operating sound levels
• R410A refrigerant
• 3 phase
• Highly efficient scroll compressor
• S imultaneous operation with multiple combinations (only
with common indoor units)
• Piping length up to 100m
• Twin, triple and quad systems available
• N
ow 8 different styles of indoor units to provide more
flexibility for different applications
• Compact twin fan design saving on valuable footprint
• Highly efficient inverter compressor
Timer remote controller Wireless remote controller Simplified remote controller
• M
ultifunctional wireless remote control with built-in
temperature control
• Piping outlet in three directions
• Fresh air knockout for improved air quality
RCS-TM80BG
• Reduced weight
RCS-KR1EG
An inspection port (450 x 450mm or more) is required at the
lower side of the indoor unit body. Distributor
(field supply)
Inverter Heat Pump
size 706
64
RCS-BH80BG.WL
System example
• Forward discharge fan - unique design for this size capacity unit
Performance
Capacity
Power input
EER/COP
Running amperes
Indoor Unit
Air-circulation (H/M/L)
Moister removal
External Static Pressure (booster)
Sound Power Level
Sound Pressure Level (H/M/L)
Dimensions (HxWxD)
Net weight
Power supply
Outdoor Unit
Sound Power Level (H)
Sound Pressure Level (H)
Dimensions (H/W/D)
Net weight
Power supply
Refrigerant circuit
Tube diameter Narrow/Wide
Max piping lenght
Max elevation difference - O.U. above/below I.U.
Chargeless piping lenght
Amount of additional refrigerant
Controller Options
kW
W
W/W
A
m /h
Liters/h
Pa
dB-A
dB-A
mm
kg
V, ph, Hz
Cooling
6,0/20,2/22,4
7,12
2,81
11,0
mm(in)
m
m
m
g/m
Cooling
6,0/25,0/28,0
9,55
2,62
14,8
SPW-D705H
3360/3190/2980
3
dB-A
dB-A
mm
kg
V, ph, Hz
size 906
Heating
6,0/22,4/25,0
6,50
3,45
10,1
11,1
Heating
6,0/28,0/31,5
8,20
3,41
12,6
Inspection port (450 x 450mm or more)
SPW-D905H
4320/4200/3960
-
13,9
176
80
48/47/46
467/1428/1230
110
216 (235)
82
51/50/49
467/1428/1230
120
220-240,1,50/60
SPW-C706VH8
71
57
SPW-C906VH8
72
57
57
1526x940x340
118
58
1526x940x340
128
380-415,3+N,50/60
size 706
9,52(3/8)/25,4(1)
100
30
30
40
size 906
12,7(1/2)/25,4(1)
100
30
30
80
Specifications subject to change without notice.
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Outdoor
Indoor
Outdoor
43°C DB
32°C DB
15°C WB
-15°C DB
19°C DB
-20°C WB
Indoor
30°C DB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
65
Multi Systems
Commercial Split-Systems (PACi)
The SPW DC inverter system is the ideal versatile
solution for air conditioning irregularly shaped
or open plan areas, as 2, 3 or 4 indoor units can
operate in multi-split configuration from a single
outdoor unit.
Any combination of indoor unit style with a common
capacity can operate in a single mode to provide an
economical solution where effective air distribution
is required.
Outdoor unit
Performance
Cooling
7,1
10,0
12,5
14,0
20,0
25,0
SPW-C256 - Inverter model
SPW-C366 - Inverter model
SPW-C486 - Inverter model
SPW-C606 - Inverter model
SPW-C706 - Inverter model
SPW-C906 - Inverter model
Heating
8,0
11,2
14,0
16,0
22,4
28,0
Combination
TRIPLE
12 x 3
16 x 3
18 x 3
25 x 3
-
TWIN
12 x 2
18 x 2
25 x 2
25 x 2
36 x 2
48 x 2
QUAD
12 x 4
18 x 4
25 x 4
SPW-FTR...EH56B
Floor/ Ceiling mounted unit
Air circulation
(H/M/L)
Sound pressure level (quiet H/M/L)
Dimensions
(HxWxD)
Net weight
SPW-FTR124EH56B
700/590/500
47/43/38
680x900x190
23,5
m3/h
dB(A)
mm
kg
SPW-SPW-FTR164EH56B
830/760/665
52/49/46
680x900x190
23,5
SPW-FTR184EH56B
830/760/665
52/49/46
680x900x190
23,5
SPW-T...H
Ceiling mounted unit
Air circulation
(H/M/L)
Sound pressure level(H/M/L)
Dimensions
(HxWxD)
Net weight
m3/h
dB(A)
mm
kg
SPW-T125H
720/600/540
35/32/30
210x910x680
21
SPW-T165H
720/600/540
35/32/30
210x910x680
21
SPW-T185H
780/660/540
36/33/30
210x910x680
21
SPW-T255H
1100/900/840
38/36/33
210x1180x680
25
SPW-T365H
1650/1380/1200
41/38/35
210x1595x680
33
SPW-T485H
1800/1560/1320
43/40/37
210x1595x680
33
SPW-T605H
1800/1560/1320
43/40/37
210x1595x680
33
SPW-X...H
Semi concealed cassette
Air circulation
(H/M/L)
Sound pressure level(H/M/L)
Dimensions - unit (HxWxD)
Dimensions - panel(HxWxD)
Net weight - unit
Net weight - panel
SPW-X125H
930/840/780
31/29/27
256x840x840
35x950x950
21
4,5
m3/h
dB(A)
mm
mm
kg
kg
SPW-X165H
930/840/780
31/29/27
256x840x840
35x950x950
21
4,5
SPW-X185H
960/840/780
31/29/27
256x840x840
35x950x950
21
4,5
SPW-X255H
1200/960/840
34/31/28
256x840x840
35x950x950
22
4,5
SPW-X365H
1680/1380/1260
39/36/33
319x840x840
35x950x950
26
4,5
SPW-X485H
1980/1500/1320
42/38/34
319x840x840
35x950x950
26
4,5
SPW-X605H
2040/1620/1380
44/40/36
319x840x840
35x950x950
26
4,5
SPW-UMR...EH56B
Concealed duct unit
Air-circulation
External static pressure std (booster)
Sound pressure level
Dimensions
Net weight
(H/M/L)
(H/M/L)
(HxWxD)
m3/h
Pa
dB(A)
mm
kg
SPW-UMR124EH56B
600/510/440
49(65)
45/43/40
266/571/852
30
SPW-UMR164EH56B
875/600/400
49(83)
45/38/33
266/571/1058
35
SPW-UMR184EH56B
875/600/400
49(83)
45/38/33
266/571/1058
35
SPW-XM...H
SPW-U...H
Mini semi concealed cassette
Air circulation
Sound pressure level
Dimensions - unit
Dimensions - panel
Net weight - unit
Net weight - panel
(H/M/L)
(H/M/L)
(HxWxD)
(HxWxD)
SPW-XM125H
540/480/420
32/29/26
283/575/575
30x625x625
16
2,4
m3/h
dB(A)
mm
mm
kg
kg
SPW-XM165H
640/510/450
36/32/28
313/625/625
30x625x625
16
2,4
SPW-XM185H
750/630/540
41/37/33
313/625/625
30x625x625
16
2,4
Concealed duct unit
Air circulation
(H/M/L)
External static pressure std (booster)
Sound pressure level
(H/M/L)
Dimensions
(HxWxD)
Net weight
SPW-US...H
SPW-XMR...EH56B
Mini semi concealed cassette
Air circulation
Sound pressure level
Dimensions - unit
Dimensions - panel
Net weight - unit
Net weight - panel
SPW-U125H
SPW-U165H
SPW-U185H
SPW-U255H
SPW-U365H
SPW-U485H
SPW-U605H
m3/h
600/510/420
720/630/540
720/630/540
1080/900/780
1800/1560/1260 1980/1800/1500 1980/1800/1500
Pa
49 (65)
40 (62)
40 (62)
50 (92)
79 (122)
78 (113)
78 (113)
dB(A) 29/26/22 (32/29/26) 30/28/25 (33/30/28) 30/28/25 (33/30/28) 34/30/27 (38/34/30) 38/33/31(42/38/33) 40/37/33(44/40/37) 40/37/33(44/40/37)
mm
310x700x630
310x1000x630
310x700x630
310x1000x630
310x1480x630
310x1480x630
310x1480x630
kg
24
25
25
32
47
47
47
(H/M/L)
(H/M/L)
(HxWxD)
(HxWxD)
m3/h
dB(A)
mm
mm
kg
kg
SPW-XMR124EH56B
700/600/500
43/40/37
296/575/575
41/730/730
16,5
2,5
SPW-XMR164EH56B
750/630/530
44/40/37
296/575/575
41/730/730
18
2,5
SPW-XMR184EH56B
750/630/530
44/40/37
296/575/575
41/730/730
18
2,5
Slim concealed duct unit
Air-circulation
External static pressure
Sound pressure level
Dimensions
Net weight
(H/M/L)
(short circuit connection)
(H/M/L)
(HxWxD)
m3/h
Pa
dB(A)
mm
kg
SPW-US125H
540/480/420
15(40)
32/30/28(34/32/30)
200x750x640
19
SPW-US165H
630/570/480
15(40)
34/32/30 (36/34/32)
200x750x640
19
SPW-US185H
750/690/600
15(40)
35/33/31 (37/35/33)
200x750x640
19
SPW-KR...GH56B
Wall mounted unit
Air circulation
Sound pressure level
Dimensions
Net weight
(H/M/L)
(H/M/L)
(HxWxD)
m3/h
dB(A)
mm
kg
SPW-KR124GH56B
720/600/420
35/31/27
285x995x203
12
SPW-KR164GH56B
720/600/420
35/31/27
285x995x203
12
SPW-KR184GH56B
780/660/480
38/34/30
285x995x203
12
SPW-KR254GH56B
1140/960/720
41/37/34
330x1140x228
21
All specifications subject to change without notice.
66
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
67
Electric VRF, ECOi
Content
Electric VRF,
ECOi
Electric VRF, ECOi – Overview
70
2 Way ECOi 72
3 Way ECOi 76
Mini ECOi 80
VRF Indoor Unit Range
96
Convenient System Control
68
128
69
Electric VRF, ECOi
Electric VRF, ECOi
Mini ECOi
2 Way ECOi
3 Way ECOi
DC-inverter control techno­logy for rapid and
powerful cooling & heating.
Mini ECOi
Since its formation in 1958, SANYO Air Conditioners has been
at the forefront of innovation with its market-leading research
and development program. From the world’s first heat pump
air conditioner in 1960 to the first 3 pipe VRF system in 1989,
SANYO continues to deliver leading technology combined with
the reliability and customer service that you would expect from
SANYO.
The ECO-i series is designed for energy savings, easy
installation, and high efficiency. Always continuing to evolve,
SANYO uses advanced technologies to meet the requirements
of diverse situations and contribute to the creation of comfort
able living spaces.
3 Way ECOi
Mini ECOi Outdoor Units
2 Way ECOi
3 Way ECOi
Type for light commercial use
Type with selection of cooling or heating operation
• Single phase or three phase power supply
• DC inverter technology combined with R410A for excellent
efficiency
Type with simultaneous heating and cooling operation
Heat Recovery Type
• DC inverter technology combined with R410A for
excellent efficiency
• Compact design for easy installation
The ever-evolving SANYO ECOi series
2 Way ECOi
• Top class COP 4.06 (In case of 4HP cooling)
• 9
indoor units can be connected to 1 outdoor unit.
(In case of 6 HP)
• I t is possible to perform cooling operation at outdoor
temperatures down to -10˚C.
• Extended operating range - better output at lower
temperatures
• Extended pipe runs of up to 150m
• Connectability of 40 indoor units from 24HP upwards
• Top class COP
• Simultaneous cooling or heating operation for up to
40 indoor units
• Top Class COP
• Realization of the smallest installation space, top class
in the industry
• Rotation operation function and back-up operation function
provided
• W
ide range of product for narrower installation space
New 14 & 16 HP
Lower running and life cycle costs
SANYO ECOi VRF systems are amongst the most effi cient
VRF systems on the market, offering COPs in excess of 4.0 at
full load conditions. The system is also designed to make sure
that we reduce the running cost of each system by using our
unique road map control routine to ensure that the most effi
cient combination of compressors are running at any one time.
Improved defrost sequencing also reduces running cost by
defrosting each outdoor coil in turn when conditions allow.
ECOi system capacity
40
35 (Number of indoor units)
40
30
33
25
20
23
15
10
13
16
26
36
29
19
5
0
70
8HP
10HP
12HP
14HP
16HP
18HP
20HP
22HP
24HP
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
71
2 Way ECOi
Electric VRF, ECOi
SPW-C....DXHN8
L5
ECOi 2 Way is a high-performance multi system
with excellent energy-saving features, designed
for creating comfortable environment when either
heating or cooling is required.
H3
C
L2
LM
B
Balance pipe
(ø 6.35)
LO
Piping design
Main piping length LM = LA + LB···≤80 m
1. MaindistributionpipesLC-LHareselectedaccordingtothe
2. capacity after the distribution joint.
Sizeofindoorunitconnectionpiping1-40aredeterminedby
3. the connection piping size on the indoor units.
SPW-C....DXHN8
L1
A
LB
LC
LD
LA
H1
4
LF
• Single footprint size for all unit capacities
Distribution joint (APR, option)
Ball valve (BV, option)
Note: Do not use commercial T-pieces for the
and .
liquid pipes of
The operating range of heating has been extended from 16˚
to 30°
• D
C inverter technology combined with R410A for
excellent efficiency
• System configuration from 8HP to 48HP
8HP ~ 48HP
• Diversity ratio 50-130%
Cooling: -10˚C DB ~ 43˚C DB
Heating: -20˚C WB ~ 15˚C WB
Save on piping cost
• Heating capacity to -20°C
H1
• Nominal ESP standard on all outdoor units
H2
H3
≤150
≤175
≤40
≤80
≤30
≤300
≤10
≤50
≤40
≤15
≤4
Note 1: The outdoor connection main piping (LO part) depends on the total capacity of the outdoor units connected to the end.
Note 2: When the main piping length (L1) (equivalent length) exceeds 90 m, increase the size of both the gas and liquid main piping (LM) by 1 step.
Reducing the refrigerant volume by reducing piping size has
extended the piping actual length to 150m (175m equivalent
piping length).
• Units available from 8-16HP as single units
Length (m)
Actual piping length
Equivalent piping length
Difference between the max. length and the min. length from the No. 1 distribution
Max. length of main piping (at max. diameter)
Max. length of each distribution
Total max. piping length including length of each distribution (only narrow tubing)
Distance between PC and AD unit
When outdoor unit is installed higher than indoor unit
When outdoor unit is installed lower than indoor unit
Max. difference between indoor units
Max. difference between outdoor units
Max. piping length
∆ L (L2–L4)
LM
1, 2~40
L1+1+2+~40+A+B+LF+LG+LH
L5
Allowable elevation ­difference
Longer piping means greater installation area
• Connectability of 40 indoor units from 24HP upwards
3
L4
L1
the No.1 distribution joint
R410A with low pressure loss enables smaller pipe sizes. This
means reduced piping space, improved workability at the site
and reduced piping material costs.
• High COP
2
Ranges that apply to refrigerant piping lengths and to differences in installation heights
Items
Marks
Contents
Allowable piping length
• Extended pipe runs of up to 150m
1
LG
H2
LH
* Be sure to use R410A distribution joints for outdoor unit connections and
piping branches.
• I ndustry low outdoor unit sound levels: from 54.5dB(A)
Extended Compressor Life
• Quiet mode offers a further 3dB(A) reduction
40
For extension
Symbol explanation
Extended operating range - better output at lower
temperatures
6
5
For extension
Within 400 mm
Within 400 mm
• Heat pump systems offer heating or cooling
LE
Specifications subject to change without notice.
Extended compressor life by uniform compressor operation times
The total operation time of the compressors is monitored by a
microcomputer, so that there is no unbalance for the operation
times of all compressors in the same refrigerant system, and
System difference of
elevation: 50m *1
compressors with a shorter operation time are operated with
preference. System example: A, C: DC inverter compressor
B, D: Constant speed compressor
Actual length: 150m*2
(Equivalent length: 175m)
Load
increase
Difference in elevation
between indoor units: 15m
*1: 40m if the outdoor unit is below the indoor unit.
*2: Total length of pipe: no more than 300m
A B
C D
50 h 30 h
60 h 10 h
Load
increase
A B
C D
Load
increase
A B
C D
A B
C D
Higher COPs - lower running costs
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
EER Cooling
HP
3,74
3,54
3,50
3,45
3,38
3,63
3,54
3,51
3,49
3,44
3,43
3,41
3,38
3,50
3,47
3,47
3,45
3,42
3,43
3,40
3,38
COP Heating
4,05
4,10
3,91
3,91
3,79
4,06
4,06
3,97
3,96
3,88
3,84
3,85
3,79
4,00
3,94
3,89
3,91
3,86
3,83
3,83
3,79
72
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
R410A
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
73
2 Way ECOi
Electric VRF, ECOi
Appearance
HP
8
C0705DXHN8
10
C0905DXHN8
12
C1155DXHN8
14
C1305DXHN8
16
C1405DXHN8
Model (SPW-)
Power supply
Cooling capacity
Heating capacity
EER Cooling
COP Heating
Running current/AMPs
Power input
Running current/AMPs
Heating
Power input
Cooling
A
kW
A
kW
380...50,60Hz
380/400/415V-3 phase/50Hz
22,40
28,00
33,50
40,00
45,00
25,00
31,50
37,50
45,00
50,00
3,74
3,54
3,50
3,45
3,38
4,05
4,10
3,91
3,91
3,79
9,7/9,2/8,9 12,9/12,3/11,8 15,6/14,9/14,3 19,6/18,6/17,9 22,5/21.3/20.6
5,99
7,90
9,58
11,6
13,3
10,0/9,5/9,1 12,7/12,0/11,6 15,7/14,9/14,3 19,4/18,5/17,9 22,3/21,2/20,4
6,17
7,75
9,60
11,5
13,2
Recommended fuse sizes (motor rated)
Dimensions (H/W/D)
Net weight
Air circulation
Gas
Piping
Liquid
connection
Balance
Ambient temperature operating range
Operating sound - normal mode
Operating sound - quiet mode
Maximum number of indoor units
32
mm
kg
m3/min
Inches
Inches
Inches
dB(A)
dB(A)
32
32
40
40
1887×890×890 (+60)
295
345
345
180
200
220
1 1/8
1 3/8
3/8
1/2
1/4
Cooling: -10°C DB +43°CDB · Heating: -20°CWB 15°CWB
54,5
55,0
56,0
61,0
62,0
51,5
52,0
53,0
58,0
59,0
13
16
19
23
26
245
150
3/4
295
160
7/8
50,40
56,50
3,63
4,06
22,7/21,6/20,8
13,9
22,7/21,6/20,8
13,9
32x2
380/400/415V-3 phase/50Hz
56,00
61,50
63,00
69,00
3,54
3,51
4,06
3,97
26,0/24,7/23,8 28,6/27,2/26,2
15,8
17,5
25,5/24,2/23,3 28,4/27,0/26,0
15,5
17,4
32x2
68,00
76,50
3,49
3,96
32,4/30,8/29,6
19,5
32,0/30,4/29,0
19,3
32x2
1x40
1x32
1887×1880×890 (+60)
590
590
640
160+160
180+160
200+160
1 3/8
5/8
1/4
Cooling: -10°C DB +43°CDB · Heating: -20°CWB 15°CWB
58,0
58,0
58,5
62,0
55,0
55,0
55,5
59,0
29
33
36
40
540
160+150
System example
26
28
30
32
34
16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8 14 C1305DXHN8
10 C0905DXHN8 12 C1155DXHN8 14 C1305DXHN8 16 C1405DXHN8 10 C0905DXHN8
10 C0905DXHN8
380/400/415V-3 phase/50Hz
73,00
78,50
85,00
90,00
96,00
81,50
87,50
95,00
100,00
108,00
3,44
3,43
3,41
3,38
3,50
3,88
3,84
3,85
3,79
4,00
35,4/33,6/32,4 38,2/36,3/35,0 42,0/39,9/38,5 44,9/42,7/41,1 45,4/43,1/41,6
21,2
22,9
24,9
26,6
27,4
35,1/33,3/32,1 38,1/36,2/34,9 41,7/39,6/38,2 44,6/42,3/40,8 44,7/42,5/41,0
21,0
22,8
24,7
26,4
27,0
1x40
1x32
1x40
1x32
2x40
2x32
1x40
2x40
1887×1880×890 (+60)
640
690
690
220+180
220+200
220+220
1 3/8
3/4
1/4
Cooling: -10°CDB +43°CDB · Heating: -20°CWB 15°CWB
63,0
63,0
64,5
65,0
60,0
60,0
61,5
62,0
40
40
40
40
640
220+160
36
38
40
42
44
16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8
10 C0905DXHN8 12 C1155DXHN8 14 C1305DXHN8 16 C1405DXHN8 16 C1405DXHN8
10 C0905DXHN8 10 C0905DXHN8 10 C0905DXHN8 10 C0905DXHN8 12 C1155DXHN8
380/400/415V-3 phase/50Hz
101,00
107,00
113,00
118,00
124,00
113,00
119,00
127,00
132,00
138,00
3,47
3,47
3,45
3,42
3,43
3,94
3,89
3,91
3,86
3,83
48,2/45,8/44,1 51,0/48,0/47,0 55,0/52,0/50,0 58,0/55,0/53,0 60,0/57,0/55,0
29,1
30,8
32,8
34,5
36,2
47,6/45,2/43,5 51,0/48,0/46,0 54,0/52,0/50,0 57,0/54,0/52,0 60,0/57,0/55,0
28,7
30,6
32,5
34,2
36,0
2x32
1x40
1x32
2x40
1x32
2x40
1x32
2x40
46
48
16 C1405DXHN8 16 C1405DXHN8
16 C1405DXHN8 16 C1405D XHN8
14 C1305DXHN8 16 C1405DXHN8
130,00
135,00
145,00
150,00
3,40
3,38
3,83
3,79
64,0/61,0/59,0 67,0/64,0/62,0
38,2
39,9
64,0/61,0/59,0 67,0/64,0/61,0
37,9
39,6
3x40
1x40
1x32
1887×2870×890 (+60)
1887×2870×890 (+60)
929
929
929
985
985
985
1035
1035
200+160+160 220+160+160 220+180+160 220+200+160 220+220+160 220+220+180 220+220+200 220+220+220
1 3/8
1 5/8
1 5/8
3/4
1/4
Cooling: -10°CDB +43°CDB · Heating: -20°CWB 15°CWB
63,0
63,5
63,5
65,0
65,5
65,5
66,5
67,0
60,0
60,5
60,5
62,0
62,5
62,5
63,5
64,0
40
40
40
40
40
40
40
40
Specifications subject to change without notice.
Dimensions of unit combinations
SANYO make it possible to link outdoor
units together for a large capacity (48HP)
3
48HP
40
50-130%
150m
50(40)m
300m
890 (Top plate dimension)
950 (Max. dimension)
790 (Installation hole pitch) 200 790 (Installation hole pitch)
1780 (Installation hole pitch)
790 (Installation hole pitch)
Indoor unit
Ifindoor/outdoorunitsneedservicing,aballvalve
(optional)cutsoffnon-operationalunitstoletother
units stay running.
System limitations
Maximum number of combined outdoor units
Maximum HP of combined outdoor units
Maximum number of connectable indoor units
Indoor/outdoor unit capacity ratio
Maximum actual piping length
Maximum level difference (when outdoor unit is lower)
Maximum total piping length in one direction
920 (Installation hole pitch)
Since all pipings are concentrated
into one pipe shaft, you can minimise
piping space and construction labour.
34 to 48 HP
2870
890 (Top plate dimension)
100 890 (Top plate dimension)
100 890 (Top plate dimension)
790 (Installation hole pitch)
200 790 (Installation hole pitch)
200 790 (Installation hole pitch)
Addition
If your indoor capacity load changes in the future, it’s easy to add on
both indoor and outdoor units using the same pipings.
1880
100 890 (Top plate dimension)
890 (Top plate dimension)
920 (Installation hole pitch)
950 (Max. dimension)
Connection
890 (Top plate dimension)
890 (Top plate dimension)
890 (Top plate dimension)
Concentration
18 to 32 HP
950 (Max. dimension)
8 to 16 HP
Outdoor unit
74
2x32
2x40
920 (Installation hole pitch)
Electric
ratings
kW
kW
18
20
22
24
10 C0905DXHN8 10 C0905DXHN8 12 C1155DXHN8 14 C1305DXHN8
8 C0705DXHN8 10 C0905DXHN8 10 C0905DXHN8 10 C0905DXHN8
2770 (Installation hole pitch)
(2 Way version illustrated)
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
R410A
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
75
3 Way ECOi
Electric VRF, ECOi
SPW-C....DZH8
Ranges that apply to refrigerant piping lengths and to differences in installation heights
Items
Marks
Contents
L1
Allowable piping length
ECOi 3 Way is one of the most advanced VRF
systems available. Not only offering high-efficiency
and performance for simultaneous heating and
cooling, its sophisticated design makes installation
and maintenance much easier.
∆ L (L2–L4)
LM
1, 2~40
L1+1+2+~40+A+B+LF+LG+LH
L5
the No.1 distribution joint
H1
Allowable elevation ­difference
H2
H3
Length (m)
Actual piping length
Max. piping length
Equivalent piping length
Difference between the max. length and the min. length from the No. 1 distribution
Max. length of main piping (at max. diameter)
Max. length of each distribution
Total max. piping length including length of each distribution (only narrow tubing)
Distance between PC and AD unit
When outdoor unit is installed higher than indoor unit
When outdoor unit is installed lower than indoor unit
Max. difference between indoor units
Max. difference between outdoor units
≤150
≤175
≤40
≤80
≤30
≤300
≤10
≤50
≤40
≤15
≤4
Note 1: The outdoor connection main piping (LO part) depends on the total capacity of the outdoor units connected to the end.
Note 2: When the main piping length (L1) (equivalent length) exceeds 90 m, increase the size of both the gas and liquid main piping (LM) by 1 step.
Specifications subject to change without notice.
SPW-C....DZH8
Industry’s smallest changeover boxes - fewer siting problems
• Simultaneous heating and cooling for total control
The SANYO solenoid valve kit is only 147mm high (without
the removable bracket) and takes its power from the indoor
unit, saving the cost of an additional supply.
Extended operating range - better output at lower
temperatures
• Single footprint size for all unit capacities (8-16HP)
The operating range for heating has been extended to
-20°C. The remote controller temperature setting for heating
operation has also been extended from 16°C to 30°C.
• D
C inverter technology combined with R410A for
excellent efficiency
• System configuration from 8HP to 48HP
• Individual indoor unit control in one SVK control box group
• No additional power supply required
• Single mounting fix point
• 2 sizes available
Fully-automatic simultaneous Cooling/Heating operation and heat recovery
• Diversity ratio 50-130%
8HP ~ 48HP
• Increased outdoor fan’s static pressure valve
Cooling: -10˚C DB ~ 43˚C DB
Heating: -20˚C WB ~ 15˚C WB
• Sound levels: from 54,5dB(A)
ATK-RZP56BGWB
ATK-RZP160BGWB
• Quiet mode offers a further 3dB(A) reduction
• Extended pipe runs of up to 150m
• COPs to 4,09
There is improved performance at lower ambient conditions
due to SANYO’s unique wrap‑around outdoor unit coil design
and active defrost management.
• Provides cooling down to -10°C ambient
• Connectability of 40 indoor units from 24HP upwards
• Improvement of energy efficiency in part load condition
operation
• Compatibility with 3 way ECOi 4-series
Individual control
(ON/OFF, Tset, Fan, Flap, etc.)
L5
At same operating mode
H3
C
L2
LM
B
Balance pipe
(ø 9.52)
LO
Piping design
Main piping length LM = LA + LB···≤80 m
1. Main distribution pipes LC-LH are selected according to the
2. capacity after the distribution joint.
Sizeofindoorunitconnectionpiping1-40aredeterminedbythe
3. connection piping size on the indoor units.
Symbol explanation
Distribution joint (APR, option)
Ball valve (BV, option)
Note: Do not use commercial T-pieces for the
and .
liquid pipes of
* Be sure to use R410A distribution joints for outdoor unit connections and
piping branches.
76
Extended compressor life by uniform compressor operation times
L1
A
LB
LC
LD
LE
LA
H1
4
LF
6
5
40
The total operation time of the compressors is monitored by a
microcomputer, so that there is no unbalance for the operation
times of all compressors in the same refrigerant system, and
For extension
Within 400 mm
Load
increase
For extension
Within 400 mm
LG
LH
1
Solenoid Valve Kit
2
H2
3
A B
C D
50 h 30 h
60 h 10 h
compressors with a shorter operation time are operated with
preference. System example: A, C: DC inverter compressor
B, D: Constant speed compressor
Load
increase
A B
C D
Load
increase
A B
C D
A B
R410A
L4
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
C D
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
77
3 Way ECOi
Electric VRF, ECOi
Appearance
HP (Combined systems)
8
10
12
14
16
18
20
22
24
26
C0705DZH8 C0905DZH8 C1155DZH8 C1305DZH8 C1405DZH8 8 C0705DZH8 10 C0905DZH8 10 C0905DZH8 10 C0905DZH8 10 C0905DZH8
10 C0905DZH8 10 C0905DZH8 12 C1155DZH8 14 C1305DZH8 16 C1405DZH8
Model
Power supply
Cooling capacity
Heating capacity
EER Cooling
COP Heating
Running current/AMPs
Cooling
Power input
Electric
ratings
Running current/AMPs
Heating
Power input
380/400/415V-3phase/50Hz
kW
22,40
28,00
33,50
40,00
45,00
50,40
kW
25,00
31,50
37,50
45,00
50,00
56,50
kW
3,78
3,45
3,41
3,45
3,38
3,57
kW
4,09
3,95
3,81
3,91
3,79
4,01
A 10,0/9,5/9,2 13,7/13,0/12,6 16,6/15,7/15,2 20,0/19,0/18,3 23,0/21,8/21,0 23,8/22,6/21,8
kW
5,93
8,12
9,82
11,60
13,31
14,10
A 10,3/9,8/9,4 13,5/12,8/12,3 16,6/15,8/15,2 19,9/18,9/18,2 22,8/21,6/20,9 23,9/22,6/21,8
kW
6,11
7,97
9,84
11,50
13,20
14,10
Recommended fuse sizes (motor rated)
Dimensions (H/W/D)
Net weight
Airflow
Gas
Discharge
Piping
connection
Liquid
Balance
Operating sound - normal mode
Operating sound - quiet mode
Maximum number of indoor units
mm
kg
m3/min
Inches
Inches
Inches
Inches
dB(A)
dB(A)
32
32
290
150
3/4
5/8
40
1887x890x890 (+60)
290
350
180
200
1 1/8
3/4
7/8
1/2
3/8
55,0
56,0
60,0
52,0
53,0
57,0
16
19
23
290
160
7/8
3/8
54,5
51,5
13
32
40
32x2
350
220
580
150+160
61,0
58,0
26
57,8
54,8
29
380/400/415V-3phase/50Hz
56,00
61,50
63,00
69,00
3,46
3,44
3,96
3,88
27,3/26,0/25,0 30,2/28,7/27,7
16,20
17,90
26,8/25,5/24,6 30,0/28,5/27,5
15,90
17,80
32x2
68,00
76,50
3,45
3,92
33,6/31,9/30,8
19,70
33,3/31,6/30,5
19,05
73,00
81,50
3,41
3,84
36,5/34,7/33,5
21,40
36,2/34,4/33,1
21,20
1x40
1x32
1x40
1x32
640
160+200
640
160+220
32x2
1887x1880x890 (+60)
580
580
160+160
160+180
1 1/8
7/8
5/8
3/8
58,0
58,5
55,0
55,5
33
36
7/8
57,8
54,8
40
61,1
57,1
40
System example
28
30
32
34
36
38
40
42
44
46
48
12 C1155DZH8 14 C1305DZH8 16 C1405DZH8 10 C0905DZH8 10 C0905DZH8 10 C0905DZH8 10 C0905DZH8 10 C0905DZH8 12 C1155DZH8 14 C1305DZH8 16 C1405DZH8
16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 10 C0905DZH8 10 C0905DZH8 12 C1155DZH8 14 C1305DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8
14 C1305DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8
380/400/415V-3phase/50Hz
380/400/415V-3phase/50Hz
78,50
85,00
90,00
96,00
101,00
107,00
113,00
118,00
124,00
130,00
135,00
87,50
95,00
100,00
108,00
113,00
119,00
127,00
132,00
138,00
145,00
150,00
3,40
3,41
3,38
3,45
3,41
3,42
3,42
3,40
3,41
3,40
3,38
3,80
3,85
3,79
3,93
3,88
3,84
3,88
3,84
3,81
3,83
3,79
39,4/37,5/36,1 43,0/40,8/39,4 45,9/43,6/42,1 47,5/45,1/43,5 50,5/48,0/46,3 53,0/51,0/49,0 57,0/54,0/52,0 60,0/57,0/55,0 63,0/60,0/58,0 66,0/63,0/60,0 69,0/65,0/63,0
23,10
24,90
26,60
27,80
29,60
31,30
33,00
34,70
36,40
38,20
39,90
39,3/37,3/36,0 42,6/40,8/39,0 45,6/43,3/41,7 46,9/44,6/43,0 49,7/47,2/45,5 53,0/50,0/48,0 56,0/54,0/52,0 59,0/56,0/54,0 63,0/59,0/57,0 65,0/62,0/60,0 68,0/65,0/63,0
23,00
24,70
26,40
27,50
29,10
31,00
32,70
34,40
36,20
37,90
39,60
1x40
1x32
2x40
1887x1880x890 (+60)
640
700
180+220
200+220
1 3/8
1 1/8
3/4
3/8
60,4
61,0
57,4
58,0
40
40
2x40
700
220+220
61,5
58,5
40
2x32
1x40
2x32
1x40
2x32
2x40
1x32
2x40
1x32
2x40
1x32
2x40
1x40
1x32
1x40
1x32
1887x2870x890 (+60)
930
930
930
990
990
990
1050
1050
160+160+200 160+160+220 160+180+220 160+200+220 160+220+220 180+220+220 200+220+220 220+220+220
1 3/8
1 5/8
1 1/8
1 3/8
3/4
3/8
60,8
61,3
61,5
62,0
62,4
62,6
63,0
63,3
57,8
58,3
58,5
59,0
59,4
59,6
60,0
60,3
40
40
40
40
40
40
40
40
Dimensions ECOi
Outdoor unit
Concentration
Connection
Since all pipings are concentrated
into one pipe shaft, you can minimise
piping space and construction labour.
SANYO make it possible to link outdoor
units together for a large capacity (48HP)
Solenoid valve kit
If indoor/outdoor units need servicing, a ball valve
(optional)cutsoffnon-operationalunitstoletother
units stay running.
System limitations
Maximum number of combined outdoor units
Maximum HP of combined outdoor units
Maximum number of connectable indoor units
Indoor/outdoor unit capacity ratio
Maximum actual piping length
Maximum level difference (when outdoor unit is lower)
Maximum total piping length in one direction
78
3
48HP
40
50-130%
150m
50(40)m
300m
Indoor unit
Addition
If your indoor capacity load changes in the future, it’s easy to add on both
indoor and outdoor units using the same pipings.
If the additional installment of outdoor and indoor units is expected, the size of refrigerant
piping should be decided according to the total capacity after the addition.
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
R410A
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
79
Mini ECOi
Electric VRF, ECOi
SPW-CR...GXH56B
SPW-CR...GXH8B
Note:Donotusecommercially
availableT-jointsfortheliquid
tubing.
SANYO’s ECOi Mini, the 2 pipe heat pump small VRF
system, is specifically designed for the European market.
Be sure to use special R410A
distribution joints (APR:
purchased separately) for
outdoorunitconnectionsand
H1 tubing branches.
L1
Offering between 11kW and 16kW cooling capacity in
3 sizes and up to 9 indoor units connected, the ECOi Mini
sets standards of performance and flexibility.
Main tube of unit
LA
L2
LC
LB
LD
n
R410A distribution joint
APR-P160BG (for indoor unit)
Utilising R410A and DC inverter technology, SANYO offers
VRF to a new and growing market.
1 st branch
Forming a new key part of the SANYO VRF line up, the ECOi
Mini is compatible with the same indoor units and controls
as the rest of the electric and gas-powered range.
SPW-CR...GXH56B
SPW-CR...GXH8B
L3
1
2
3
n-1
H2
Unit distribution tube
Installation possible even in narrow space
Features at a glance
HP
Model name
Power supply
Cooling capacity
Heating capacity
EER cooling
COP heating
• Single phase or three phase power supply
• One AMP start current
• DC inverter technology combined with R410A for
excellent efficiency
4
SPW-CR365GXH56B/SPW-CR365GXH8B
kW
kW
Running current/AMPs
A
Power input
kW
Running current/AMPs
A
Heating
Power input
kW
Recommended fuse size (motor rated)
Dimensions (H/W/D)
mm
Net weight
kg
m3/min
Air circulation
Refrigerant amount at shipment
kg
Gas
Inches
Piping connection
Liquid
Inches
Operating sound normal mode
dB(A)
Quiet mode
dB(A)
Maximum number of indoor units
• COP of up to 4.34
Electric
rating
• Diversity ratio 50-130%
• 150m pipe runs
• Cooling operation to -10°C
• Full range of indoor units and control options
• Compact outdoor unit 1230x940x340mm
11,20
12,50
4,06
4,34
14,1/4,34
2,76
14,7/4,52
2,88
Cooling
16
16
5/8
3/8
51,0
48,0
6
5
6
SPW-CR485GXH56B/SPW-CR485GXH8B
SPW-CR605GXH56B/SPW-CR605GXH8B
230V, 1 phase, 50/60Hz/400, 3 phase, 50/60Hz
14,00
15,50
16,00
17,60
3,66
3,39
4,10
3,84
19,6/6,02
23,4/7,18
3,83
4,57
19,9/6,13
23,4/7,19
3,90
4,58
16
16
16
16
1230x940x340
104
100
3,5
5/8
3/4
3/8
3/8
51,0
52,0
48,0
49,0
8
9
Specifications subject to change without notice.
Wide operating range
The operating range for heating operation is to -20°C, the
cooling range is to -10°C. The remote controller temperature
setting offers a range from 16°C to 30°C.
Up to 9 indoor units per system
Ranges that apply to refrigerant piping lengths and to differences in installation heights
Items
Marks
Contents
L1
8HP ~ 48HP
Allowable piping length
Cooling: -10˚C DB ~ 43˚C DB
Heating: -20˚C WB ~ 15˚C WB
∆ L (L2–L3)
1, 2~ n
1+ 2+~ n-1+L1
Allowable elevation ­difference
H1
H2
L = Length, H = Height
Highest COPs - lowest running costs
HP
4
EER Cooling
4.06
COP Heating
4.34
5
3.66
4.10
Length (m)
Actual piping length
≤150
Max. piping length
Equivalent piping length
≤175
Difference between the max. length and the min. length from the No. 1 distribution joint
≤40
Max. length of each distribution tube
≤30
Total max. piping length including length of each distribution (only narrow tubing)
≤200
When outdoor unit is installed higher than indoor unit
≤50
When outdoor unit is installed lower than indoor unit
≤40
Max. difference between indoor units
≤15
Specifications subject to change without notice.
6
3.39
3.84
R410A
80
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
81
Gas Driven Heat Pumps
Content
Gas Driven
VRF
Gas Heat Pumps, GHP - Overview
84
ECO G Power
86
ECO G W-Multi 88
ECO G 3Way Multi
92
ECO G Water Heat Exchanger
94
VRF Indoor Unit Range
96
Convenient System Control
82
128
83
Gas Heat Pumps, GHP
Gas Driven VRF
The Gas Heat Pump M Series
Benefits
Exhaust
SANYO has been developing GHP VRF systems
since 1980, during which time we have been
committed to delivering ground-breaking
technology. As a result, the commercial range of
GHP VRF systems is leading the industry in the
development of efficient and flexible systems,
making them the natural choice for commercial
projects, especially for those projects where power
restrictions apply. As you would expect, all of our
gas driven VRF systems have the highest reliability
rates in the industry and a leading customer service
program.
The GHP Motor’s torque and rpm control functions
are comparable with an inverter type electric air
conditioner. Thus the GHP ensures individual and
efficient control and regulation as you are used
from an electric inverter airconditioner.
The advanced M Series of gas driven VRF systems offers
increase efficiency and performance across the range.
Now more powerful than ever before, it can connect to
up to 48 indoor units.
Improvements include increased part load performance,
reduced gas consumption with a Miller-cycle engine and
reduced electrical consumption from using DC fan motors.
• U
p to 71kW of cooling from a current consumption of
6.18 AMPs
High-efficiency operation
Fan
Comparison of the start times for heating operation
Room temperature (˚C )
All models are equipped with a high-performance air exchanger
Gas heat
and a newly developed refrigerant heat exchanger
forpump
highefficiency operation, making them one of the most energyefficient solutions on the market.
Comparison of heating capacity
Heating capacity (% )
Gas heat pump
Electric heat pump
Electric heat pump
Lowest nitrogen oxide emissions
Accumulator
The GHP VRF systems have the lowestTime
nitrogen
axis (inoxide
case of the same load)
emissions, 66% below the standard. In a pioneering
development, the SANYO GHP features a brand new lean-burn
combustion system that utilises air fuel ratio feedback control
to reduce NOx emissions to an all time low.
Outside air temperature (˚C)
Comparison of the start times for heating operation
Room temperature (˚C )
Compressor
Gas heat pump
Excellent economy
The SANYO GHP provides quick and powerful cooling/heating
and increases delivery of heat into the space by the efficient
recovery of heat from the engine cooling water, which is
injected into the refrigerant circuit by an highly efficient plateheat-exchanger.
Power supply problems?
If you are short of electrical power, gas heat pump could
be the perfect solution:
• Single phase power supply across the range
• R
educes capital cost to upgrade power substations to
run heating and cooling systems
• The option of natural gas or LPG as its main power source
• R
educes power loadings within a building especially
during peak periods
• A
water heat exchanger to connect to domestic hot water
systems 13-25 HP (2-pipe units only)
• E lectricity supply freed up for other uses such as IT
servers, commercial refrigeration, manufacturing,
lighting etc.
• Option of DX or chilled water for indoor heat exchange
• Reduced CO2 emissions
Gas heat
Electric heat pump
Time axis (in case of the same load)
In addition, the use of engine waste heat ensures that our gas
heat pump air conditioner requires no defrost cycle, therefore
providing continuous 100% heating performance in severe
weather conditions with an outside air temperature as low as
-20°C. During cooling mode the rejected heat from the engine
is available for use with in a DHW system and can supply up to
25 kW of hot water at 75 °C.
Outside air t
GHP Outdoor Heat Exchanger
Water coil
• Runs on gas and just needs single phase supply
• E nables the building’s electrical power supply to be
used for other critical electrical demands
Comparison
Heating cap
High performance
With its advanced heat exchanger design, this new GHP
system offers improved efficiency and reduced running costs,
which, coupled with improved engine management systems,
have greatly improved the system COP rating.
DX coil
• Integrated DX and hot water coil
• No defrost required
Water chiller option
• Faster reaction to demand for heating
Our GHP system is also available with a water chiller option,
which can be combined with individual outdoor units or as part
of a DX chilled water mix of indoor units. The system can be
operated via a BMS system or a SANYO supplied control panel,
with chilled water set points from -15°C up to 15°C and heating
set points up to 25°C to 55°C.
New electrical power generator model
The biggest breakthrough in recent GHP technology is the
launch of the ECO G Power, which provides 4.0kW of power.
That’s enough electricity to power 8 PCs or 40 indoor units.
84
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
R410A
85
ECO G Power
GHP with electricity generation
Gas Driven VRF
SGP-EGW190M2G2W
The 2 Way Gas Driven VRF with an electrical
power generator
SANYO’s ECO G Power is a revolution in air
conditioning design. Fitted with a permanent
magnet, non-bearing type generator, it is the first
VRF system that can supply heating, cooling, hot
water and now also a supply of electrical power.
Each ECO G Power unit has a 4.0kW generator,
which provides enough power for 40 indoor units
or the equivalent of 8 PCs.
SGP-EGW190M2G2W
• I nnovative technology that reduces CO2 emissions by
more than 30%
• 2 way air conditioning system providing cooling or heating
• C
an provide both electricity and hot water in heating and
cooling mode
HP
Model name
Generate electricity during heating or cooling operation
Generate electricity and air conditioning (heating or cooling) at
the same time by using remaining engine power. ECO G Power
can generate from 2.3 to 3.95kW electricity at a generation
efficiency of more than 40%.
• Up to 4kW electricity generated
• Very efficient generator
• H
ot water provided when cooling and when heating
above 7°C*
High power
engine
Power
generator
• permanent
magnet type
• non-bearing
Line linkage
converter
Double clutch
compressor
• 22kW hot water generation capacity
• 20HP model provides 56kW cooling or 63kW heating
• Can connect to up to 32 indoor units
• 200m maximum allowable piping length (L1)
• IU/OU capacity ratio 50 - 130%
* referring to outside temperature
Cooling
Capacity
Production of electricity
Generates from 2kW to 4kW depending on air conditioning load
Production of electricity (kW)
4.5
Heating
Hot water (cooling mode)
Power generater capacity at rating
Electricity
Cooling
Heating
STD
Low temp*1
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
Cooling
Heating STD
Heating LOW
Cooling
Air conditioning only Heating
COP
AVE
Max COP (Inc generater, hot water)
Cooling
Height
mm
Size
Width
mm
Depth
mm
Weight
kg
Starter amperes
A
Gas
Liquid
Pipe
Balance
Fuel gas
Exhaust drain port
mm
dB(A)
Operation sound
Indoor/outdoor capacity ratio
Number of connections indoor*
Gas consumption
• Electricity is output to line linkage converter
20
SGP-EGW190M2G2W
56,0
63,0
67,0
22,0
1,35
1,01
44,0 (38,3)*
48,7 (43,0)*
62,1 (56,4)*
1,33 (1,41)*
1,34 (1,43)*
1,34 (1,42)*
1,78
33
SGP-EW120M2G2W
SGP-EGW190M2G2W
91,5
103,0
109,5
34,0
DC 2,5 (Max 4,3)
2,20
2,02
68,5
76,8
98,9
1,29
1,31
1,30
1,81
1800
875
30
ø28,58
ø15,88
ø9,52
1660
30
ø31,75
ø19,05
ø9,52
58
61
32
36
SGP-EW150M2G2W
SGP-EGW190M2G2W
101,0
113,0
120,0
37,5
2,70
2,02
75,6
84,8
109,4
1,29
1,30
1,30
1,80
2248
1800 + 100 (Min distance) + 1800
1000 (+60)
1685
1740
30
30
ø31,75
ø38,10
ø19,05
ø19,05
ø9,52
ø9,52
R3/4 (bolt, thread)
ø25 rubber hose
61
61
50-130%
48
* In case of not generater working. * 1 Low temp condition: outdoor temperture 2˚C
4
40
SGP-EGW190M2G2W
SGP-EGW190M2G2W
112,0
126,0
134,0
44,0
DC 5,0 (Max 8,6)
2,70
2,02
88,0
97,4
124,2
1,23
1,27
1,25
1,78
45
SGP-EGW190M2G2W
SGP-EW240M2G2W
127,0
143,0
142,0
52,0
DC 2,5 (Max 4,3)
2,70
2,55
104,9
101,0
121,3
1,18
1,38
1,28
1,69
1720
30
ø38,10
ø19,05
ø9,52
63
Specifications subject to change without notice.
3.5
3
2.5
2
1.5
1
0.5
0
0
10
20
30
40
50
60
70
80
90
100
Air conditioning load (%)
R410A
86
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
87
ECO G W-Multi
Gas Driven VRF
SGP-EW...M2G2W
ECO G W-Multi 2 Way for
Heat Pump Applications
The M Series 2 Way not only offers improved
performance but also increased flexibility. Now
available as multi-systems, many combinations
are possible, from 13HP to 50HP, allowing for
more power and enabling accurate matching of
a system building load. Additional new features
include part load engine management and
compressor run hour equalisation.
SGP-EW...M2G2W
• Reduced gas consumption by Miller-cycle engine
• Reduced electrical power consumption by using DC motors
• N
ew lightweight design by use of aluminium engine block
reduces weight by 110kg
• Part load efficiencies increased
• Connectability increased - now up to 48 indoor units
• Multi-systems with combinations from 13HP up to 50HP
• 200m maximum allowable piping length (L1)
• D
iversity ratio 50-200% (single models only; excluding
ECO G Power)
• Extended pipe runs (total 780m)
• Equivalent sound levels to electric VRF systems
• Quiet mode offers a further 2dB(A) reduction
• Chiller option
- 9HP (25kW cooling - 30kW heating)
- 18HP (50kW cooling - 60kW heating)
• 10,000 run hours between engine service intervals
(equivalent to one maintenance every 3.2 years*)
• Full heating capacity down to -20°C
HP
Model name
13
16
SGP-EW120M2G2W SGP-EW150M2G2W
Cooling
STD
Capacity
Heating
Low temp*1
Hot water (cooling mode)
Cooling
Electricity
Heating
Cooling
Gas consumption
Heating STD
Heating LOW
Cooling
COP
Heating
AVE
Max COP (inc hot water)
Cooling
Height
Size
Width
Depth
Weight
Starter amperes
Gas
Liquid
Pipe
Balance
Fuel gas
Exhaust drain
Operation sound
Indoor/outdoor capacity ratio
Number of indoor connections
kW
kW
kW
kW
kW
kW
kW
kW
kW
35,5
40,0
42,5
12,0
0,85
1,01
24,5
28,1
36,8
1,40
1,37
1,39
1,87
mm
mm
mm
kg
A
45,0
50,0
53,0
16,0
1,35
1,01
31,6
36,1
47,3
1,37
1,35
1,36
1,85
1800
790
ø25,40
ø12,70
dB(A)
ø28,58
ø12,70
ø9,52
R3/4 (bolt thread)
ø25 rubber hose
57
50-200 %
32
36
20
25
26
29
32
33*
36*
40*
45*
50
SGP-EW190M2G2W SGP-EW240M2G2W SGP-EW120M2G2W SGP-EW120M2G2W SGP-EW150M2G2W SGP-EW120M2G2W SGP-EW150M2G2W SGP-EW190M2G2W SGP-EW190M2G2W SGP-EW240M2G2W
SGP-EW120M2G2W SGP-EW150M2G2W SGP-EW150M2G2W SGP-EW190M2G2W SGP-EW190M2G2W SGP-EW 190M2G2W SGP-EW240M2G2W SGP-EW240M2G2W
56,0
71,0
71,0
80,5
90,0
91,5
101,0
112,0
127,0
142,0
63,0
80,0
80,0
90,0
100,0
103,0
113,0
126,0
143,0
160,0
67,0
75,0
85,0
95,5
106,0
109,5
120,0
134,0
142,0
150,0
20,0
25,0
24,0
28,0
32,0
32,0
36,0
40,0
45,0
50,0
1,35
1,35
1,70
2,20
2,70
2,20
2,70
2,70
2,70
2,70
1,01
1,54
2,02
2,02
2,02
2,02
2,02
2,02
2,55
3,08
38,3
60,9
49,0
56,1
63,2
62,8
69,9
76,6
99,2
121,8
43,0
58,0
56,2
64,2
72,2
71,1
79,1
86,0
101,0
116,0
56,4
64,9
73,6
84,1
94,6
93,2
103,7
112,8
121,3
129,8
1,41
1,14
1,40
1.38
1,37
1,41
1,39
1,41
1,25
1,14
1,43
1,34
1,37
1,36
1,35
1,41
1,39
1,43
1,38
1,34
1,42
1,24
1,39
1,37
1,36
1,41
1,39
1,42
1,31
1,24
1,92
1,54
1,87
1,86
1,85
1,90
1,89
1,92
1,69
1,54
2248
1800
1800 + 100 (min distance) + 1800 (in a straight installation)
1000 (+60)
820
850
1580
1580
1580
1610
1610
1640
1670
1700
30
ø28,58
ø31,75
ø31,75
ø31,75
ø31,75
ø31,75
ø38,10
ø38,10
ø38,10
ø15,88
ø15,88
ø19,05
ø19,05
ø19,05
ø19,05
ø19,05
ø19,05
ø19,05
ø9,52
R3/4 (bolt thread)
ø25 rubber hose
58
62
60
60
60
61
61
61
63
65
50-200 %
50-130 %
36
36
48
*In these combinations, EGW190M2G2W is able to connect to a W-multi system
instead of a EW190M2G2W.
*1 Low temp condition: outdoor temperture 2˚C.
Specifications subject to change without notice.
• No defrost cycle
* Assuming 3120 running hrs per year - 12 hrs x 5 days x 52 weeks
R410A
88
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
89
8 operating
hours
8 operating
hours
8 operating
hours
Example: 40hp (approximately 20hp x 2), load of around 20hp, 8 operating hours.
Up to this time
ECO G W-Multi
W-Multi
to this
time
TotalUp
operating
hours:
16 hours
W-Multi
Total operating
hours: 8 hours
Load of
Load of
Stop
around 10hp
around 10hp
Example: 40hp
(approximately 20hp x 2), load of around
20hp, 8 operating hours.
8 operating
8 operating
hours
Totalhours
operating hours: 16 hours
Total operating hours: 8 hours
Up to this time
W-Multi
Easy to add additional units in the future
Saving Energy
Load can easily be increased in the future by the addition of
indoor and outdoor units without having to plumb pipe shafts.
• Energy savings achieved by the Appropriate Load Divider
Function
*When specifying plumbing, please choose the size according to the horsepower after the
increase of units.
Added outdoor units.
(Only for models with the
same refrigerant.)
Load of
around 10hp
8 operating
hours
Uplifetime
to thisLoadtime
Long
of
Load of
around 10hp
8 operating
hours
Load of
around 20hp
8 operating
hours
Stop
Added indoor units.
Open 16 hours
Open
operating
hours:
Total
operating
hours: 8 hours
DueTotal
to the
appropriate
load
divider,
up tooperation
30%
ofunder
operating
Continuous
the maintenance
in need of
stopMachine
maintenance
hours
can
be
reduced.
During
the
period,
such
as
spring
and
Total operating hours: 16 hours
Totaloperation
operatingunder
hours:
hours
Continuous
the8maintenance
stop
autumn, when
the load is low, appropriate load divider will stop
Machine in need of maintenance
excess
outdoor units. When comparing the total of operating
Machine in need
of maintenance
Operating
Operating
Close
Close
Operating
Operating
Closeup to
Close 30%* reduction
hours, maximum of
is
possible.
backup
backup
to this time
W-Multi
Up to thisUp
time
W-Multi
Maintenance
during holidays
Maintenance during weekdays
holidays
Maintenancefunction
during weekdays
•Maintenance
Renewalduring
period
prolonged due to rotation
System stops during maintenance
Open
Operating
Open
A
B
Machine in need of maintenance
Maintenance during holidays
A
backup
Example: 40hp (approximately 20hp x 2), load of around 20hp, 8 operating hours.
Example of a system
Maximum possible number of outdoor units to be combined: 2 units
Maximum horsepower of combined outdoor units: 50hp
Maximum possible number of indoor units to be connected: 48 units *1
Indoor/outdoor units capacity ratio: 50%~130% *2
heat exchanger
balance
valve
V2
oil-surface
sensor
V1
compressor
compressor oil collecting valve
uid pipe
electronic control valve
oil-surface gas pipe
heat exchanger
separator
balance
valve
V2
oil-surface
sensor
electronic
V1
oil collecting control
valve
electronic control valve valve
balance
compressor
valve compressor
oil
rator
V2
rface
nsor
s pipe
V1
mpressor
pressor
Outdooroil units
EV
separator
balance
valve
V2
oil-surface
sensor
electronic V1
compressor control
compressor
oil collecting valve
valvevalve
electronic control
electronic
control
valve
Indoor units
8 operating
hours
Close
Outdoor units
oil collecting valve
electronic
control
valve
Indoor units
electronic
control
valve
Maintenance during holidays
Up to this time
stop
A
W-Multi
System stops during maintenance
Open
B
Indoor units
A 2100hr
stop B 2050hr
System startup
Continuous operation under
maintenance
B is operating
Only unitthe
realization
of of maintenance
Machine
in need
averaging
operating hours
n
Outdoor
units
Introducing the oil/refrigerant balance control system
electronic
electronic
balance
The amounts ofcontrol
oil and refrigerant
between compressors are
control
valve
valvea signal from an
valveoil-surface sensor or a
kept in balance by
refrigerant gas controller mounted on the oil separator, allowing
the V1
exchange of oil and refrigerant through a balance pipe.
Close
stop
A
Operating
Machine in need of
maintenance
Operating hours
Outdoor units
Operating
Open
Operating
Close
backup A
B
Maintenance during holidays
realization of
averaging
operating hours
stop stop
Astop B
A
stop
A
B
A 2100hr B 2050hr
realization of
averagingOperating hours stop
Operating
hours
A 2100hr
B 2050hr
stop
operating hours
A
A 2105hr B 2058hr
realization of
averaging
operating hours
Operating
B
Maintenance during weekdays
A
Load reduced
stop
B
B
stop Only machine B is operating
A
B
A
essor
ssor
oil collecting valve
tronic control valve
Indoor units
Operating hours
Operating hours
A 2105hr B 2058hr
A 2100hr B 2053hr
Indoor units
Load reduced
Only machine B is operating
utdoor units
90
stop
B
Operating
Outdoor unit
Hot water piping allowable pressure
Hot water circulation rate
Hot water tube size
Outlet temp 75˚C
12.0
16.0
kW
20.0
22.0
25.0
MPa
0.7
3.9
m3/h
Rp 3/4
System startup
Only unit B is operating
A 2100hr B 2053hr
Load increased
A
B
Magnetic Relay
A 2100hr B 2053hr
Load increased
B
Pump
System
Operatingstartup
hours
A 2100hr B 2053hr
Only unit B is operating
Load reduced
W-Multi
realizationOnly
of machine B is operatingOnly machine B is operating
Machine A and B are operating
averaging
stop function
Example
of the rotation
operating hours
Ease of construction
Bo
B
B
Machine A and B are operating
Operating
hours
Combining all pipes, which wereOperating
needed hours
for
each outdoor unit, into a
A 2105hr
B 2058hr
pipe in each system.
(Number
half) hours
Operating
Operating
hours of
A pipes
B 2050hrby
2100hris reduced
A
Electric Design
stop
A
A
System startup
hours
B is operating
Only unitOperating
Load increased
Machine A and B are operating
A
G.H.P.
SANYO
B
Hot water
Combining all pipes, which were needed for each outdoor unit, into a
pipe in each system. (Number of pipes is reduced by half)
Combining all pipes, which were needed for each outdoor unit, into a
• to
Ease
of construction
is improved
byisintroducing
large capacity
Up
this time
pipe
in+each
system. (NumberW-Multi
of 20hp
pipes
+ 20hpreduced by half)
20hp
20hp
common pipe
Up to this timeOperating hours
W-Multi
Operating hours
A 2105hr B 2058hr
A 2100hr B 2053hr
By combining all pipes,
which were needed for each
indoor
Load
reduced
Loadofincreased
unit, into a common pipe in each system,
number
pipes
Electric the
connection:
Only which
machine B isleads
operatingto240AC,
Machine A and B are operating
are reduced by half*
ease of3A
construction.
Furthermore, space of pipes within pipe shafts can be reduced
+ 20hp
20hp + 20hp
by20hp
2/3.*
Water
tank
*System with approximately 40hp (20hp x 2 units)
Combining all pipes, which were needed for each
outdoor
unit, into a
Electric
Design
pipe in each
system.
(Number of pipes is reduced by
half)
+ 20hp
+ 20hp
20hp
20hp
Up to this time
W-Multi
Magnetic Relay
Manometer
Expansion tank
Boiler
Cold water
Pump
Valve
• All the items illustrated in this draw (exception outdoor unit)
are not SANYO’s supply.
• During start up, set temperature value of the water in the
outdoor unit’s parameter.
Load increased
Machine A and B are operating
stop
A
B
Example of a system with approximately 40hp
Combining all pipes, which were needed for each outdoor unit, into a
Rating Conditions: Cooling Indoor 27°C DBpipe
19°C in
WBeach
Outdoor
35°C (Number
DB 24°C WB
20°CbyDBhalf)
Outdoor 7°C DB 6°C WB
system.
ofHeating
pipes isIndoor
reduced
Up to this time
SGP-EW120M2G2W
SGP-EW150M2G2W
SGP-EW190M2G2W
SGP-EGW190M2G2W
SGP-EW240M2G2W
Electric connection:
240AC, 3A
Pump
stop
A
EV
backup
B
V2
ce
or
stop Operating
A
B
B
Operating hours
Load reduced
If one outdoor unit stops due to unexpected trouble, backup
function in operational outdoor units will automatically kick in
and continue operating. Even when a necessity for a service
Total operating hours: 16 hours
Total operating hours: 8 hours
arises, one can cut off the system being served with the
closing valve inExample
the outdoor
unit,
enabling
continuous
operation
of the rotation function
with functional outdoor units.
stop
B
Capacity at cooling standard point
System startup
A 2105hr B 2058hr
Maintenance during weekdays
stop
A
The engine waste heat, which is normally exhausted into the
atmosphere, is recovered via the heat exchanger and effectively
used as hot water, so the GHP Chiller acts as a sub system that
alleviates the load on the client’s main hot water system, and
therefore offers ‘free’ hot water.
Only unit B is operating
Up to this time
Indoor units
e pipeEV
e
8 operating
hours
Operating
Operating
Close
• Automatic Backup Operating Function
enables continuous
backup
operation, even during trouble
EV
Indoor units
d pipe
lectronic controlSystem
valve chain diagram
il
or
• Example:
System40hp
will(approximately
not stop even
to Operating
20hpduring
xOpen
2), loadmaintenance,
of around 20hp, 8due
operating
Operating hours.
Open
System stops during maintenance
Manual Backup Operating Function
Machine in need of
maintenance
Up to this time
W-Multi
Continuous
operation under the maintenance
stop during weekdays
Maintenance
is
possible
because
it can
Load of
Load of
Load of
Stop
continue
operating duringaround
maintenance.
around 10hp
10hp
around 20hp
hours
sensor
Indoor units
Up tooperation,
this time even during maintainance
W-Multi
Non-stop
8 operating
Machine
in need of maintenance
4 direction
EV
valve
Outdooroilunits
tion
alve
V2
fluid pipe
V1
compressor oil collecting valve
compressor
balance
pipe
electronic
control
valve
4 direction
EV
valve
nce pipe
electronic
control
valve
balance
valve
oil
separator
heat exchanger
gas pipe
heat exchanger
*1 Maximum possible number of outdoor
units to be connected is 24.
gas pipe
*2 Capacity of indoor units connection is
fluid
pipe
Minimum) 50% of the capacity of the smallest outdoor unit within the system.
Maximum) 130%: total capacity of the system outdoor units.
balance pipe
Indoor units are same as multi series for buildings.
4 direction
4 direction
*There
are un connectable.
valve exist some indoor units whichvalve
• System Advantage
Maintenance during weekdays
Operating hours
Total operating hours: 8 hours
B
weekdays
stop Maintenance
stop during
Close
Close
A
B
A 2100hr B 2050hr
Total operating hours: 16 hours
*Hot water capacity is approximately 50% of gas consumption at partial load.
Operating
in need hours
of
Continuous
operation
underoperating
theMachine
maintenance
operating
average
the
of each
stop time, will
maintenance
outdoor unit. This will result in prolongation
of
maintanance
or
Continuous operation under the maintenance
stop
Machine in need of maintenance
replacement
period. Close
Operating
Operating
stop stop Close
stop
Maintenance during holidays
Main pipe: Maximum gas
pipe diameter 38.1
Maximumfluidpipediameter
19.05
Hot Water Supply Function
Machine in need of
maintenance
Operating
Operating
(Only for models with the
same refrigerant.)
If there is a possibility for addition after
setting up, please plan it so that the
placementofaballvalve(soldseparately)
onabranchpipeonindoor/outdoorunits
is possible.
W-Multi
Operating
Machine in needis
of run
Open
Open
Rotation
function,
which
from outdoor
units with
low Operating
System
stops during
maintenance
maintenance
W-Multi
Load of
around 10hp
8 operating
hours
Load of
around 20hp
8 operating
hours
Energy
the Appropriate Load Divider
Up •
to this
time savings achieved by
W-Multi
Operating
Operating
Open
Open
Function
System
stops during maintenance
Energy savings are achieved by the Appropriate Load Divider
Function, which enables efficient operation by concentrating the
cooling/heating capacity to one outdoor unit and stopping the
other. Compared to conventional machines with a similar COP,
this function allows an achievement of energy savings and thus
reduces the running costs, especially in part-load-seasons like
spring and autumn.
Up to this time
Load of
around 20hp
8 operating
hours
Stop
around 10hp
8 operating
hours
System stops during maintenance
oil
separator
Gas Driven VRF
Load of
Load of
Load of
Stop
around 10hp
around 10hp
around 20hp
Example: 40hp (approximately
20hp x 2), load of around
20hp, 8 operating hours.
8 operating
8 operating
8 operating
hours
hours
hours
W-Multi
20hp + 20hp
20hp + 20hp
Example of a system with approximately 40hp
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
R410A
91
ECO G 3 Way Multi
For simultaneous heating and cooling operation
Gas Driven VRF
SGP-EZ...M2G2
Additional parts
Still the only 3 way GHP system in Europe,
the M Series ECO G 3 Way offers even more
performance and outstanding features when
you need simultaneous heating and cooling.
Now with capacities available from 16HP to
25HP, SANYO offers the greatest choice and
flexibility to solve any power problem or site
requirement.
SGP-EZ...M2G2
Solenoid valve kit
Distribution joint kits
ACC-3WAY-AGB
ATK-RZP56BGWB (For 74 to 254 indoor unit)
ATK-RZP160BGWB (For 364 to 604 indoor unit)
APR-RZP224BGB (16.0 kW or less)
APR-RZP680BGB (28.0 kW or less)
APR-RZP1350BGB (More than 35 kW)
* For conference rooms and other locations where
low noise is required, pay attention to the installation
location and install on a corridor etc.
• Simultaneous heating and cooling for total control
• Quiet mode offers a further 2dB(A) reduction
• Reduced gas consumption by Miller-cycle engine
• 1
0 000 run hours between engine service intervals
(equivalent to one maintenance every 3.2 years*)
• Reduced electrical power consumption by using DC motors
Solenoid valve controller
• Full heating capacity down to -20°C
Excellent performance
• Part load efficiencies increased
• No defrost cycle * Assuming 3120 running hrs per year 12 hrs x 5 days x 52 weeks
SANYO 3 WAY multi system is capable of simultaneous heating/cooling and individual operation of each indoor unit
by only one outdoor unit. As a result, efficient individual air conditioning is possible in buildings having diverse room
temperatures.
• Connectability increased to up to 36 indoor units
• Ideal for all bulding types
Improved maintenance intervals
The unit only needs to be serviced every 10,000 hours. This is the best in the industry.
• Now available in 16, 20 and 25HP
• Full heating capacity down to -20°C
• 200m maximum allowable piping length
• Option of using LPG as a power supply (increases
flexibility and avoids problems of potential site restrictions
in the future. The purer fuel is also excellent for further
reductions in CO2 emissions)
• New use of aluminium engine block reduces weight by 110kg
• Diversity ratio 50-200%
• Extended pipe runs (total 780m)
HP
Model name
Cooling
Capacity
Electricity
Gas consumption
COP
Size
Heating
Cooling
Heating
Cooling
Heating STD
Heating LOW
Cooling
Heating
AVE
Height
Width
Depth
Weight
Starter amperes
Pipe
Gas
Discharge
Liquid
Fuel gas
Exhaust drain
Operation sound
Indoor/outdoor capacity ratio
Number of indoor connections
STD
Low temp*
kW
kW
kW
kW
kW
kW
kW
kW
mm
mm
mm
kg
A
16
SGP-EZ150M2G2
45,0
50,0
53,0
1,35
1,01
31,6
36,1
47,3
1,37
1,35
1,36
845
20
SGP-EZ190M2G2
56,0
63,0
67,0
1,35
1,01
38,3
43,0
56,4
1,41
1,43
1,42
2248
1800
1000 (+60)
845
30
ø28,58
ø22,22
mm
dB(A)
57
36
Max. 36 indoor units
3 WAY GHP MULTI enables
simultaneous heating and
cooling operation through
each solenoid valve kit.
Liquid pipe
medium-temperature,
medium-pressure liquid pipe
Suction pipe
low-temperature,
low-pressure gas pipe
Discharge pipe
high-temperature,
high-pressure gas pipe
875
ø25,40
ø19,05
R3/4 (bolt thread)
ø 25 rubber hose
58
50-200% *1
36
*Low temp condition: outdoor temperture 2˚C *1 Indoor unit can be connected to up to 16kW model (model size 60)
92
25
SGP-EZ240M2G2
71,0
80,0
75,0
1,35
1,54
60,9
58,0
64,9
1,14
1,34
1,24
Up to 35% energy saving (SANYO estimate)
Effective heat recovery system enables up to 35% energy saving
The waste heat removed from the cooled room is effectively used as a heat source for the room to be heated. As a
result, the load on the compressor and heat exchanger on the outdoor unit can be reduced, enabling excellent heat
recovery.
Solenoid Valve Kit ATK-RZP56BGWB, ATK-RZP160BGWB
120m piping allows effective system designs
Allowable piping length is a max. of 120m (actual length of 145m). This allows flexible installation and system designs.
Up to 36 indoor units are capable of simultaneous heating/cooling operation.
62
R410A
36
Specifications subject to change without notice.
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
93
ECO G Water Heat Exchanger
For hydronic operations
Gas Driven VRF
SGP-WE...M1
Mixed System Application
The SANYO ECO G Water Heat Exchanger
can provide water at a wide range of
temperatures suitable for a wide variety
of commercial applications ranging from
comfort air conditioning to food processing
or the replacement of boilers and other
systems.
*
SGP-WE...M1
• New 25 kW and 50 kW capacity models
• In cooling (chiller) mode provides water from -15°C to 15°C
Operating condition
Water temperature of water heat exchanger unit
Outdoor side intake air temperature
Cooling
Outlet 7°C
35°C DB
Heating
Outlet 45°C
7°C DB, 6°C WB
• I n heating mode can provide hot water up to 55°C, for
example for under floor heating applications
• Includes water flow protection to prevent freezing
• S-Link communication
• All controllers and optional PCBs can be used for control
• Combined with a water heat
exchanger unit, the SANYO
GHP can create a flexible
system--the ideal replacement
for existing chiller and boiler
systems.
* Standard DX type indoor unit system
• The GHP Multi System can
have an indoor unit plus a GHP
chiller. When the two systems
are operated independently,
an outdoor unit with 130%
capacity can be connected.
Note: The mode of running of outdoor unit depends on the water heat exchanger’s mode. The water pump is not
included in the water heat exchanger unit. For simultaneous operation, however, the maximum capacity is 130%.
Please inquire details of this system design of SANYO.
• High flexibility
• Lighter and smaller
• Range of new water terminal/fan coil units
• S plit system means reduced installation cost and the use
of a less powerful circulation pump
• O
ne touch changeover between cooling and heating
operation
• T he system can accommodate up to 120m (actual length)
of piping between the outdoor unit and the water heat
exchanger, allowing flexibility of installation location
• T he system can use antifreeze coolant, so it can produce
cold water even at -15°C, thereby complying with “brine
specifications”
EGO G Water Heat Exchanger
Model No.
SGP-EW120M2G2W
SGP-EW150M2G2W
SGP-EW190M2G2W and
SGP-EGW190M2G2W
SGP-EW240M2G2W
Electrical rating
Cooling capacity
Heating capacity
Cooling capacity
Heating capacity
Cooling capacity
Heating capacity
Cooling capacity
Heating capacity
Cooling power input
Heating power input
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
Power supply
Size
Height
Width
Depth
Weight
Standard cold/hot water flow rate
Hydrostatic loss
Holding water quantity inside the unit
Minimum holding water quantity outside the unit
Piping refrigerant
Heat exchanger
Water circuit limit pressure
Anti-freezing protection system
Gas pipe
Liquid pipe
mm
mm
mm
kg
m3/h
kPa
m3
m3
mm
mm
MPa
SGP-WE80M1
SGP-WE170M1
25
30
30
35,5
25
37,5
30
45
25
50
30
60
25
56
30
67
0,01
0,01
0,01
0,01
220/230/240V Single Phase 50Hz
1000
550
965
125
160
4,3
8,6
8,5
11,3
0,01
0,02
0,28
0,50
ø22,22
ø28,58
ø9,52
ø15,88
hot/cold heat exchanger
0,686
Protective thermostat
Specifications subject to change without notice.
R410A
94
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
95
VRF Indoor Unit Range for ECOi & GHP
VRF (ECOi & GHP) Indoor Units
Wide choice of models depending on the indoor requirements
Model size
Cooling
Heating
Cooling
Heating
Capacity kW
Capacity BTU/h
X type
Semi-Concealed Cassette
XM type
Semi-Concealed
7
2,2
2,5
7500
8500
9
2,8
3,2
9600
11000
12
3,6
4,2
12000
14000
16
4,5
5,0
15000
17000
18
5,6
6,3
19000
21000
SPW-X075XH
Panel
PNR-XD484GHAB
SPW-X095XH
Panel
PNR-XD484GHAB
SPW-X125XH
Panel
PNR-XD484GHAB
SPW-X165XH
Panel
PNR-XD484GHAB
SPW-X185XH
Panel
PNR-XD484GHAB
SPW-XM075XH
Panel
PNR-XM185
SPW-XM095XH
Panel
PNR-XM185
SPW-XM125XH
Panel
PNR-XM185
SPW-XM165XH
Panel
PNR-XM185
SPW-XM185XH
Panel
PNR-XM185
22
6,4
7,0
22000
24000
25
7,3
8,0
25000
27000
SPW-X255XH
Panel
PNR-XD484GHAB
30
9,0
10,0
30000
34000
36
10,6
11,4
36000
39000
48
14,0
16,0
47800
54600
60
16,0
18,0
54600
61500
SPW-X365XH
Panel
PNR-XD484GHAB
SPW-X485XH
Panel
PNR-XD484GHAB
SPW-X605XH
Panel
PNR-XD484GHAB
76
22,4
25,0
76400
85300
96
28,0
31,5
95500
107500
Wireless remote control
Type with separately
Type with built-in
installed reception
reception part
part





SPW-SR254GXH56B
Panel
PNR-S253GHANB


SPW-LDR254GXH56B
Panel
PNR-LD254GHAB


SPW-ADR74GXH56B SPW-ADR94GXH56B SPW-ADR124GXH56B
Panel
Panel
Panel
PNR-AD124GHB
PNR-AD124GHB
PNR-AD124GHB
ADR type
Semi-Concealed
Cassette 1-Way Air Discharge
SPW-SR74GXH56B
Panel
PNR-S124GHB
SR type
Semi-Concealed Cassette
2-Way Air Discharge
SR94GXH56B
Panel
PNR-S124GHB
SR124GXH56B
Panel
PNR-S124GHB
SR164GXH56B
Panel
PNR-S124GHB
SR184GXH56B
Panel
PNR-S124GHB
SPW-LDR94GXH56B SPW-LDR124GXH56B SPW-LDR164GXH56B SPW-LDR184GXH56B
Panel
Panel
Panel
Panel
PNR-LD254GHAB PNR-LD254GHAB PNR-LD254GHAB PNR-LD254GHAB
LDR type
Semi-Concealed
Slim Cassette
Functions
25,48 type
DR type
Concealed Duct
SPW-DR254GXH56B
US type
Concealed Duct
SPW-US075XH
SPW-US095XH
SPW-US125XH
SPW-US165XH
SPW-US185XH
U type
Concealed Duct
SPW-U075XH
SPW-U095XH
SPW-U125XH
SPW-U165XH
SPW-U185XH
FTR type
Floor/Ceiling Mounted Units

SPW-DR764GXH56BSPW-DR964GXH56B

SPW-U255XH
SPW-U365XH
SPW-U485XH

SPW-U605XH
SPW-FTR74EXH56B SPW-FTR94EXH56B SPW-FTR124EXH56B SPW-FTR164EXH56B SPW-FTR184EXH56BSPW-FTR224EXH56B
T type
Ceiling-Mounted Unit
K type
Wall Mounted Unit
SPW-DR364GXH56BSPW-DR484GXH56B
76,96 type
SPW-T125XH
SPW-K075XH
SPW-K095XH
SPW-T165XH
SPW-T185XH
SPW-T225XH
SPW-T365XH
SPW-T485XH
SPW-K125XH








KR type
Wall Mounted Unit
SPW-KR74GXH56B SPW-KR94GXH56B SPW-KR124GXH56B SPW-KR164GXH56B SPW-KR184GXH56B
SPW-KR254GXH56B
FR type
Floor Standing Unit
SPW-FR74GXH56B SPW-FR94GXH56B SPW-FR124GXH56B SPW-FR164GXH56B SPW-FR184GXH56B
SPW-FR254GXH56B

SPW-FMR74GXH56BSPW-FMR94GXH56BSPW-FMR124GXH56BSPW-FMR164GXH56BSPW-FMR184GXH56B
SPW-FMR254GXH56B

FMR type
Concealed Floor Standing Unit
GU type
Total Heat Exchanger
SPW-GU055XH
SPW-GU075XH

SPW-GU105XH
Wideroperation
96
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Comfortable autoflap control
Self-diagnosing
function
Automaticrestartfunctionfor
power failure
Automatic fan
operation
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Air Sweep
Mild dry
Built-in
drain pump
97
X type
semi-concealed cassette
VRF (ECOi & GHP) Indoor Units
SPW-X...XH
Controller Options
Air intake chamber
Panel
Timer remote controller Wireless remote controller Simplified remote controller
The award winning range of X type cassettes
are smaller, shallower and lighter than previous
models and feature a 950 x 950mm panel
throughout. The DC fan motor and air discharge
louvre ensure quiet, optimum air distribution.
RCS-SH80BG.WL
CMB-FS140AGB Air intake plenum
PNR-XD484GHAB
CMB-GS140AG Air intake box
SPW-X...XH
RCS-TM80BG
RCS-BH80BG.WL
RCS-KR1EG
Both Air intake plenum and
Air intake box is necessary
• Compact design
• Reduced sound levels (from previous models)
The flap can be removed easily for washing with water.
Indoor unit specifications
Model Name
Power source
• DC fan motor for increased efficiency
Cooling
capacity
• Powerful drain pump gives 850mm lift
Heating
capacity
• Lightweight design
Lighter and thinner, easier
installation!
The top class lightest weight with 26 kg (for
type36~60),bodyheightonly256mm(7~25),
so that installation is possible even in narrow
ceilings.
• Fresh air knockout
• Branch duct connection
Easy fine adjustment of the
body suspension height!
Thefourcornersoftheceilingpanelhave
adopted removable corner pockets.
Drain Pump of
about 850 mm
from the
ceiling surface
 Even after installation, fine adjustment of
the suspension height is possible easily by
removing the corner pockets.
SPW-X075XH
kW
BTU/h
kW
BTU/h
kW
kW
A
A
Cooling
Heating
Cooling
Running
amperes
Heating
Type
Fan motor Airflow rate (H/M/L)m³/min
Output kW
Power sound level (H/M/L)
dB(A)
Sound pressure sound (H/M/L) dB(A)
Height
mm
Dimensions Width
mm
Depth
mm
Liquid (flare)
mm
Piping
Gas (flare)
mm
connections
Drain piping
Net weight
kg
Power
input
2,2
7500
2,5
8500
SPW-X095XH
SPW-X125XH
SPW-X165XH
SPW-X185XH
SPW-X255XH
SPW-X365XH
SPW-X485XH
SPW-X605XH
220/230/240V, 1 phase - 50, 60 Hz
2,8
3,6
4,5
5,6
7,3
10,6
14
16
9600
12000
15000
19000
25000
36000
47800
54600
3,2
4,2
5,0
6,3
8,0
11,4
16,0
18,0
11000
14000
17000
21000
27000
39000
54600
61400
0,033/0,032/0,032
0,033/0,032/0,032 0,035/0,034/0,034 0,042/0,041/0,041 0,070/0,069/0,069 0,099/0,097/0,097 0,107/0,105/0,105
0,023/0,022/0,022
0,023/0,022/0,022 0,023/0,023/0,023 0,031/0,031/0,031 0,062/0,060/0,060 0,095/0,093/0,093 0,100/0,098/0,098
0,22/0,21/0,20
0,22/0,21/0,20
0,23/0,22/0,21
0,29/0,27/0,26
0,49/0,46/0,44
0,67/0,63/0,60
0,72/0,68/0,65
0,19/0,18/0,17
0,19/0,18/0,17
0,20/0,19/0,18
0,26/0,25/0,24
0,48/0,45/0,43
0,67/0,63/0,60
0,76/0,71/0,68
Turbo fan
15,5/14/13
16/14/13
20/16/14
28/23/21
33/25/22
34/27/23
0,05
0,09
42/40/38
45/42/39
50/47/44
53/49/45
55/51/47
31/29/27
34/31/28
39/36/33
42/38/34
44/40/36
256 + <35>
319 + <35>
840 <950>
840 <950>
6,35
9,52
12,7
15,88
VP-25
21+ <4,5>
26 + <4,5>
The values in < > for external dimensions and Net weight are the values for the optional ceiling panel.
Specifications subject to change without notice.
Light, thin, and attractive
design with easy installation
The direction of the air intake grille
can be changed. A wireless remote
control light receiver can be installed
by changing the corner cover. The
installationcanbedoneinashorttime.
Easy servicing of the drain pan
Alarge-diameter(45mm)drainpaninspectionporthasbeenprovided,and
drain pan and drain pump can be cleaned easily.
R410A
98
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
99
XM type
mini semi-concealed cassette
VRF (ECOi & GHP) Indoor Units
SPW-XM...XH
Controller Options
Panel
Timer remote controller
Wireless remote controller
Simplified remote controller
Designed to fit exactly into a 600x600mm ceiling
grid without the need to alter the bar configuration,
the XM is ideal for small commercial and retro
fit applications. In addition, the improvements to
efficiency make this one of the most advanced
units in the industry.
RCS-XM18BG.WL
SPW-XM...XH
• Fresh air knock out
PNR-XM185
Special designed flap
Indoor unit specifications
Model Name
Power source
• Multidirectional air flow
• Anti-mould and anti-bacteria washable filters
• Powerful drain pump gives 850mm lift
The flap can be
removed easily for
washing.
Cooling
capacity
Heating
capacity
Lighter and slimmer, easier installation
A lightweight unit at 26 kg (for type 36-60), the unit is also very
slim with a height of only 281 mm, making installation possible
even in narrow ceilings.
Up to 281 mm
kW
BTU/h
kW
BTU/h
kW
kW
A
A
Cooling
Heating
Cooling
Running amperes
Heating
Type
Airflow rate (H/M/L)m³/min
Fan motor
Output
kW
Power sound level (H/M/L)
dB(A)
Pressure sound level (H/M/L)
dB(A)
Height
mm
Dimensions
Width
mm
Depth
mm
Liquid (flare) mm (inches)
Piping
Gas (flare) mm (inches)
connections
Drain piping
Net weight
kg
Power input
• Turbo fans and heat exchanger fins with improved design
• DC fan motors with variable speed, new heat exchangers,
etc. ensure an efficient power consumption
RCS-TM80BG
SPW-XM075XH
SPW-XM095XH
2,2
7500
2,5
8500
2,8
9600
3,2
11000
0,034/0,031/0,030
0,024/0,021/0,020
0,26/0,23/0,21
0,24/0,21/0,19
9/8/7
41/38/36
30/27/25
RCS-BH80BG.WL
SPW-XM125XH
SPW-XM165XH
220/230/240V, 1 phase - 50, 60Hz
3,6
4,7
12000
15000
4,2
5,0
14000
17000
0,037/0,034/0,031
0,044/0,040/0,037
0,027/0,024/0,021
0,034/0,030/0,027
0,29/0,26/0,23
0,37/0,33/0,29
0,27/0,24/0,21
0,35/0,31/0,27
Centrifugal fan
10/9/8
12/11/10
0.030
43/40/37
47/43/39
32/29/26
36/32/28
283
575 <625>
575 <625>
6,35 (1/4)
12,7 (1/2)
VP-20
19 + <2,7>
Heating: Indoor air temperature 20°C DB, outdoor air temperature 7°C DB/6°C WB.
RCS-KR1EG
SPW-XM185XH
5,6
19000
6,3
21000
0,055/0,049/0,040
0,045/0,039/0,030
0,47/0,42/0,33
0,45/0,40/0,31
14/13/11
52/48/44
41/37/33
Specifications subject to change without notice.
A drain height of approx. 850 mm from the ceiling surface
The drain height can be increased by approximately 350 mm
over the conventional value by using a high-lift drain pump, and
long horizontal piping is possible.
Up to 300 mm
Up to 850 mm
R410A
100
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
101
ADR type
semi-concealed cassette
VRF (ECOi & GHP) Indoor Units
SPW-ADR...GXH56B
Controller Options
Panel
Timer remote controller
The ADR unit features reduced sound
levels, ­compact design and improved
airflow distribution.
Wireless remote controller
(Transmitter, common part)
Simplified remote controller
RCS-TRP80BG.WL
SPW-ADR...GXH56B
PNR-AD124GHB
• Low sound, lightweight and compact
Compact Size in the top class of the industry
• Ideal for hotel bedroom applications
The compact design keeps unit width and height to a minimum
and delivers the industry’s smallest panel width, giving you
plenty of leeway in selecting an installation space.
• Ease of service access in restricted locations
Indoor unit specifications
Model Name
Power source
Cooling capacity
Heating capacity
• Built-in drain pump provides 850mm lift
• A
uto-flap and auto-swing functions to remotely
control air direction
Airflow and distribution is automatically altered depending
on the operational mode of the unit.
auto flap section
SPW-ADR74GXH56B
kW
BTU/h
kW
BTU/h
kW
kW
A
A
Cooling
Heating
Cooling
Runningamperes
Heating
Type
Fan motor
Airflow rate (H/M/L)m³/min
Output
kW
Power sound level (H/M/L)
dB(A)
Pressure sound level (H/M/L)
dB(A)
Height
mm
Dimensions
Width
mm
Depth
mm
Liquid (flare)
mm
Pipingconnections Gas (flare)
mm
Drain piping
Net weight
kg
Power input
• Ultra light design: only 17kg
RCS-BH80AG.WL
RCS-TM80BG
SPW-ADR94GXH56B
220/230/240V, 1 phase - 50, 60 Hz
2,8
9600
3,2
11000
0,064/0,064/0,067
0,039/0,039/0,040
0,25/0,24/0,24
0,17/0,17/0,17
Sirocco fan
2,2
7500
2,5
8500
8/7/6
SPW-ADR124GXH56B
3,6
12000
4,2
14000
9/8/7
0,02
44/42/40
33/31/29
47/45/42
36/34/31
300 + <30>
600 <760>
560 <620>
6,35
12,7
VP-25
17 + <2,5>
The values in < > for external dimensions and Net weight are the values for the optional ceiling panel.
Specifications subject to change without notice.
2.7m
20°
RCS-KR1EG
40°
Cooling/(Fan)
Heating/(Hi,M)
R410A
102
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
103
SR type
semi-concealed cassette
VRF (ECOi & GHP) Indoor Units
SPW-SR...GXH56B
Controller Options
Panel
Timer remote controller
Realisation of thin, compact and light units
Remarkable size and weight reductions have
been achieved by improvement of the design
around the fan. In addition, compared to the
previous model the size and weight for the type
18 has been reduced by approximately 30%
body volume and to 30kg weight.
Wireless remote controller
(Transmitter, common part)
Simplified remote controller
RCS-SS80BG.WL
SPW-SR...GXH56B
PNR-S253GHANB (For 254 type)
PNR-S124GHB (For 74-184 type)
Airflow and distribution is automatically altered depending
on the operational mode of the unit.
auto flap section
2.7m
20°
40°
Cooling/(Fan)
Heating/(Hi,M)
Drain up is possible up to 500mm from the drain port.
300mm or less
500mm or less
310 mm
Maintenance of the drain pump is possible
from two sides, from the left side (piping
side) and from the inside of the unit.
Indoor unit specifications
Model Name
Power source
RCS-TM80BG
SPW-SR74GXH56B
RCS-BH80G.WL
RCS-KR1EG
SPW-SR94GXH56B
SPW-SR124GXH56B
SPW-SR164GXH56B
SPW-SR184GXH56B
SPW-SR254GXH56B
220/230/240V, 1 phase - 50, 60Hz
kW
2,2
2,8
3,6
4,5
5,6
7,3
Cooling capacity
BTU/h
7500
9600
12000
15000
19000
25000
kW
2,5
3,2
4,2
5,0
6,3
8,0
Heating capacity
BTU/h
8500
11000
14000
17000
21000
27000
Cooling
kW
0,095
0,086/0,092/0,097
0,088/0,093/0,099
0,103/0,097/0,091
0,091/0,097/0,103
0,135/0,145/0,154
Power input
Heating
kW
0,062
0,055/0,060/0,064
0,057/0,061/0,066
0,070/0,065/0,060
0,060/0,065/0,070
0,100/0,109/0,117
Cooling
A
0,45
0,44/0,45/0,45
0,44/0,45/0,45
0,45/0,45/0,45
0,45/0,45/0,45
0,64/0,65/0,66
Running
amperes
Heating
A
0,30
0,28/0,29/0,30
0,28/0,29/0,30
0,29/0,29/0,30
0,29/0,29/0,30
0,46/0,48/0,49
Type
Sirocco
Airflow rate (H/M/L)m³/min
8,0/7,0/6,0
9,0/8,0/7,0
9,6/8,6/7,6
11,0/9,0/8,0
19,0/16,0/14,0
Fan motor
Output
kW
0,03
0,05
Power sound level (H/M/L)
dB(A)
40/38/35
44/40/37
45/42/39
46/44/40
49/46/44
Pressure sound level (H/M/L)
dB(A)
30/27/24
33/29/26
34/31/28
35/33/29
38/35/33
Height
mm
358
350 + <8>
Dimensions
Width
mm
840 <1060>
1140 <1360>
Depth
mm
600 <680>
Liquid (flare)
mm
6,35
9,52
Piping
Gas (flare)
mm
12,7
15,88
connections
Drain piping
VP-25
Net weight
kg
23 + <7>
30 + <9>
The values in < > for external dimensions and Net weight are the values for the optional ceiling panel.
Specifications subject to change without notice.
Simple maintenance
The drain pan is equipped with site wiring and can be removed.
The fan case has a split construction, and the fan motor can be
removed easily when the lower case is removed.
R410A
104
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
105
LDR type
semi-concealed slim cassette
VRF (ECOi & GHP) Indoor Units
SPW-LDR...GXH56B
Controller Options
Panel
Timer remote controller
Designed for installation within the ceiling
void, the LDR range of slimline 1 Way blow
cassettes feature powerful yet quiet fans
for up to 4.2 metres.
PNR-LD254GHAB
Drain height
Indoor unit specifications
Model Name
Power source
• Suitable for standard and high ceilings
300mm or less
• Built-in drain pump provides 747mm lift
• Easy to install and maintain
Simplified remote controller
RCS-TRP80BG.WL
SPW-LDR...GXH56B
• Ultra-Slim
Wireless remote controller
(Transmitter, common part)
850mm
or less
• Hanging height can be easily adjusted
• Uses a DC fan motor to improve energy-efficiency
With 3 types of air-blow systems, the units can be used in
various ways.
(1) One-direction down-blow
system
Powerful one-direction “downblow” system reaches the floor
even from high ceilings (up to
4.2m).
(2) Two-direction ceiling-mounted system
RCS-TM80BG
RCS-BH80BG.WL
RCS-KR1EG
SPW-LDR94GXH56B
SPW-LDR124GXH56B
SPW-LDR164GXH56B
SPW-LDR184GXH56B
SPW-LDR254GXH56B
220/230/240V, 1 phase - 50, 60 Hz
kW
2,8
3,6
4,5
5,6
7,3
Cooling capacity
BTU/h
9600
12000
15000
19000
25000
kW
3,2
4,2
5,0
6,3
8,0
Heating capacity
BTU/h
11000
14000
17000
21000
27000
Cooling
kW
0,105/0,110/0,115
0,105/0,110/0,115
0,105/0,110/0,115
0,110/0,115/0,120
0,115/0,120/0,125
Power
input
Heating
kW
0,075/0,080/0,085
0,075/0,080/0,085
0,075/0,080/0,085
0,080/0,085/0,090
0,085/0,090/0,095
Cooling
A
0,50/0,50/0,51
0,50/0,50/0,51
0,50/0,50/0,51
0,53/0,53/0,54
0,55/0,55/0,56
Running
amperes
Heating
A
0,36/0,37/0,38
0,36/0,37/0,38
0,36/0,37/0,38
0,38/0,39/0,40
0,40/0,41/0,42
Type
Sirocco fan
Fan
12/10/9
12/11/10
13/11,5/10
18/15/13
Airflow rate (H/M/L)m³min
motor
Output
kW
0,05
Power sound level (H/M/L)
dB(A)
47/45/44
47/46/45
49/47/45
56/51/47
Pressure sound level (H/M/L)
dB(A)
36/34/33
36/35/34
38/36/34
45/40/36
Height
mm
200 + <20>
Dimensions
Width
mm
1000 <1230>
Depth
mm
710 <800>
Liquid (flare)
mm
6,35
9,52
Piping
Gas (flare)
mm
12,7
15,88
connections
Drain piping
VP-25
Net weight
kg
21 + <5,5>
22 + <5,5>
The values in < > for external dimensions and Net weight are the values for the optional ceiling panel.
Specifications subject to change without notice.
“Down-blow” and “front-blow”
systems are combined in a ceilingmounted unit to blow air over a
wide area.
(3) One-direction ceiling-mounted
system
This powerful ceiling-mounted
“front-blow” system efficiently
air-conditions the space in front of
the unit.
R410A
106
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
107
DR type
concealed duct high-static pressure
VRF (ECOi & GHP) Indoor Units
SPW-DR...GXH56B
Controller Options
The DR range of ducted units offers
improved design flexibility for extended
duct layouts as a result of their increased
external static pressures.
Timer remote controller
Wireless remote controller
Simplified remote controller
RCS-TM80BG
RCS-BH80BG.WL
RCS-KR1EG
25-48 Type
76-96 Type
SPW-DR...GXH56B
• Can be used as 1:1 split system if required
System example
• Complete flexibility for ductwork design
An inspection port (450 x 450mm or more) is required at the
lower side of the indoor unit body. Distributor (field supply).
• C
an be located into a weatherproof housing
for external siting
Indoor unit specifications
Model Name
Power source
Cooling capacity
Heating capacity
• Air off sensor avoids cold air dumping
Inspection port (450 x 450mm or more)
Rap valve kit
The types 76 and 96 require two rap valve kits for each unit.
kW
BTU/h
kW
BTU/h
kW
kW
A
A
Cooling
Heating
Cooling
Running
amperes
Heating
Type
Airflow rate (H/M/L) m³/min
Fan motor
Output
kW
External static pressure Pa
Power sound level (H/M/L)
dB(A)
Pressure sound level (H/M/L)
dB(A)
Height
mm
Dimensions
Width
mm
Depth
mm
Liquid (flare)
mm
Piping connections Gas (flare)
mm
Drain piping
Net weight
kg
Power
input
• Configurable air temperature control
SPW-DR254GXH56B
SPW-DR364GXH56B
SPW-DR484GXH56B
SPW-DR764GXH56B
SPW-DR964GXH56B
220/230/240V, 1 phase - 50, 60 Hz
7,3
10,6
14,0
22,4
28,0
25000
36000
47800
76400
95500
8,0
11,4
16,0
25,0
31,5
27000
39000
54600
85300
107500
0,480/0,505/0,530
0,520/0,545/0,570
0,600/0,660/0,710
0,870/0,900/0,930
1,270/1,330/1,390
0,480/0,505/0,530
0,520/0,545/0,570
0,600/0,660/0,710
0,870/0,900/0,930
1,270/1,330/1,390
2,29/2,30/2,31
2,46/2,46/2,47
2,80/2,90/3,00
4,05/4,06/4,07
6,04/6,06/6,07
2,29/2,30/2,31
2,46/2,46/2,47
2,80/2,90/3,00
4,05/4,06/4,07
6,04/6,06/6,07
Sirocco fan
23/22/21
30/28/25
36/35/33
56/53,1/49,6
72/70/66
0,2
0,35
0,2*2
0,4*2
186
176
167
176
216
55/54/53
56/55/53
58/57/55
59/58/57
62/61/60
44/43/42
45/44/42
47/46/44
48/47/46
51/50/49
420
450
467
1065
1428
620
1230
9,52
15,88
19,05
22,22
VP-25
47
50
54
110
120
Specifications subject to change without notice.
ATK-RX160AGB
R410A
108
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
109
US type
concealed duct
VRF (ECOi & GHP) Indoor Units
SPW-US...XH
Controller Options
Timer remote controller
Wireless remote controller
Simplified remote controller
RCS-TM80BG
RCS-BH80BG.WL
RCS-KR1EG
The ultra slim US type is one of the leading
products of its type in the industry. With a
depth of only 200mm it provides greater
flexibility and can be used in far more
applications.
In addition, its high-efficiency and extremely
quiet sound levels make it very popular
with many users, including hotels and small
offices.
SPW-US...XH
• Ultra-slim profile: 200 mm for all models
Ultra-slim profile for all models
Indoor unit specifications
Model Name
Power source
• DC fan motor greatly reduces power consumption
Cooling capacity
• Ideal for hotel application with very narrow false ceilings
200mm
• Anti-mould washable filters included
Heating capacity
• 40 pa static pressure enables ductwork to be fitted.
• Includes drain pump
Drain pump with increased power!
By adoption of a high-lift drain pump, the drain piping rise height
can be increased to 785mm from the lower surface of the body.
Up to 300mm
Up to
500mm
285mm
kW
BTU/h
kW
BTU/h
kW
kW
A
A
Cooling
Heating
Cooling
Running
amperes
Heating
Type
Airflow rate (H/M/L) m³/min
Fan motor
Output
kW
External static pressure Pa
Power sound level (H/M/L)
dB(A)
Pressure sound level (H/M/L)
dB(A)
Height
mm
Dimensions
Width
mm
Depth
mm
Liquid (flare) mm (inches)
Piping connecGas (flare)
mm (inches)
tions
Drain piping
Net weight
kg
Power input
• Easy maintenance and service by external electrical box
SPW-US075XH
2,2
7500
2,5
8500
0,036/0,036/0,036
0,026/0,026/0,026
0,26/0,26/0,26
0,23/0,23/0,23
8/7/6
10-30
43/42/40
28/27/25
SPW-US095XH
SPW-US125XH
SPW-US165XH
SPW-US185XH
220/230/240V, 1 phase - 50, 60Hz
2,8
3,6
4,5
5,6
9600
12000
15000
19000
3,2
4,2
5,0
6,3
11000
14000
17000
21000
0,040/0,040/0,040
0,042/0,042/0,042
0,049/0,049/0,049
0,064/0,064/0,064
0,030/0,030/0,030
0,032/0,032/0,032
0,039/0,039/0,039
0,054/0,054/0,054
0,30/0,30/0,30
0,31/0,31/0,31
0,37/0,37/0,37
0,48/0,48/0,48
0,27/0,27/0,27
0,28/0,28/0,28
0,34/0,34/0,34
0,45/0,45/0,45
Sirocco fan
8,5/7,5/6,5
9/8/7
10,5/9,5/8
12,5/11,5/10
0.05
15-30
15-40
45/44/42
47/45/43
49/47/45
52/50/48
30/29/27
32/30/28
34/32/30
35/33/31
200
750
640
6,35 (1/4)
12,7 (1/2)
VP-20
19
Specifications subject to change without notice.
R410A
110
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
111
U type
concealed duct
VRF (ECOi & GHP) Indoor Units
SPW-U...XH
Controller Options
Timer remote controller
Wireless remote controller
Simplified remote controller
RCS-TM80BG
RCS-BH80BG.WL
RCS-KR1EG
The U type ducted systems are the ideal
solution for flexible, concealed air conditioning
and the standard 200mm spigots ensure
simple, hassle-free connection to spiral
ductwork. The external static pressure can
be increased via an optional booster cable to
provide increased design flexibility.
SPW-U...XH
• Industry-leading low sound levels from 22 dB(A)
Unified body height of approximately 310 mm for
all models
• Built-in drain pump provides 785mm lift
Even models with different capacities can be installed smoothly
in the ceiling.
• Easy to install and maintain
System examples
7-22°C Air off temperature control as standard
An inspection port (450 x 450mm or more) is required
at the lower side of the indoor unit body.
• Able to control air off temperature
• Reduces cold drafts
• Accurate room temperature controls
• Air off sensor avoids cold air dumping
23°C
External electrical equipment box makes maintenance easy
• Configurable air temperature control
Lowest noise levels in the industry
The static pressure outside the unit can be
­increased
12°C
By using the booster cable, the static pressure outside the unit
can be increased.
type
standard
with booster cable use
(Pa)
7-9-12
49
69
16-18
40
62
25
50
92
36
79
122
48-60
78
113
Flexible air distribution is achieved by discharge grilles
More powerful drain pump
By adoption of a high-lift drain pump, the drain piping rise height
can be increased to 785mm from the lower surface of the body.
Up to 300mm
Up to
500mm
285mm
Indoor unit specifications
Model Name
Power source
SPW-U075XH SPW-U 095XH
Coil sensor
SPW-U125XH
SPW-U165XH SPW-U185XH SPW-U255XH
SPW-U365XH
SPW-U485XH SPW-U605XH
220/230/240V, 1 phase - 50, 60 Hz
kW
2,2
2,8
3,6
4,5
5,6
7,3
10,6
14,0
16,0
Cooling capacity
BTU/h
7500
9600
12000
15000
19000
25000
36000
47800
54600
kW
2,5
3,2
4,2
5,0
6,3
8,0
11,4
16,0
18,0
Heating capacity
BTU/h
8500
11000
14000
17000
21000
27000
39000
54600
61500
0,094/0,100/0,106
0,096/0,102/0,109
0,180/0,195/0,210 0,312/0,327/0,342
0,308/0,325/0,341
Cooling
kW
Power
input
Heating
kW
0,082/0,088/0,094
0,084/0,090/0,097
0,168/0,183/0,198 0,300/0,315/0,330
0,296/0,313/0,329
A
0,45/0,46/0,47
0,44/0,45/0,46
0,83/0,86/0,89 1,44/1,45/1,46
1,42/1,43/1,44
Running Cooling
amperes Heating
A
0,40/0,41/0,42
0,39/0,40/0,41
0,78/0,81/0,84 1,39/1,40/1,41
1,36/1,37/1,38
Type
Sirocco fan
Airflow rate (H/M/L) m³/min
10/8,5/7
12/10,5/9
18/15/13
30/26/21
33/30/25
Fanmotor
Output
kW
0,05
0,07
0,14
External static pressure Pa
49(69)
40(62)
50(92)
79(122)
78(113)
Power sound level (H/M/L)
dB(A)
40/37/33
41/39/36
45/41/38
49/44/42
51/48/44
Pressure sound level (H/M/L)
dB(A)
(32)/29/26/22
(33)/30/28/25
(38)/34/30/27 (42)/38/33/31
(44)/40/37/33
Height
mm
310
Dimensions Width
mm
700
1000
1480
Depth
mm
630
Liquid (flare)
mm
6,35
9,52
Piping
Gas (flare)
mm
12,7
15,88
connections
Drain piping
VP-25
Net weight
kg
24
25
32
47
The values in ( ) for the external static pressure and operating sound are for use of booster cable.
Specifications subject to change without notice.
R410A
112
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
113
FTR type
floor/ceiling mounted
VRF (ECOi & GHP) Indoor Units
SPW-FTR...EXH56B
Controller Options
Timer remote controller
The FTR type units offer the flexibility
of floor or ceiling application without
the need for further modification at
installation stage.
Wireless remote controller
(Transmitter, common part)
Simplified remote controller
RCS-TH80AG.WLB
SPW-FTR...EXH56B
• 3 speed centrifugal fan
Further comfort improvement with airflow distribution.
• Anti-mould and anti-bacterial washable filters
RCS-TM80BG
SPW-FTR...EXH56B
Indoor unit specifications
Model Name
Power source
• Horizontal flap swinging or set on a fixed position
Cooling capacity
• Shallow design
Heating capacity
• Easy to install
Power input
kW
BTU/h
kW
BTU/h
kW
kW
A
A
Cooling
Heating
Cooling
Running
amperes
Heating
Type
Fan motor
Airflow rate (H/M/L) m³/min
Output
kW
Power sound level (H/M/L)
dB(A)
Pressure sound level (H/M/L)
dB(A)
Height
mm
Dimensions Width
mm
Depth
mm
Liquid (flare) mm (inches)
Piping conGas (flare)
mm (inches)
nections
Drain piping
Net weight
kg
SPW-FTR74EXH56B
SPW-FTR94EXH56B
2,2
7500
2,5
8500
2,8
9600
3,2
11000
0,65/0,65/0,65
0,65/0,65/0,65
0,29/0,29/0,29
0,29/0,29/0,29
RCS-BH80AG.WLB
RCS-KR1EG
SPW-FTR124EXH56B
SPW-FTR164EXH56B
220/230/240V, 1 phase-50 Hz
3,6
4,5
12000
15000
4,2
5,0
14000
17000
SPW-FTR184EXH56B
SPW-FTR224EXH56B
5,6
19000
6,3
21000
0,88/0,88/0,88
0,88/0,88/0,88
0,41/0,41/0,41
0,41/0,41/0,41
6,4
22000
7,0
24000
Sirocco fan
10,5/9/7,5
0,07
60/54/49
49/43/38
12/10,8/9,7
15/13,5/12
0,09
62/58/54
51/47/43
63/60/57
52/49/46
680
900
190
6,35 (1/4)
12,7 (1/2)
VP-26
23,5
Specifications subject to change without notice.
floor or ceiling application
R410A
114
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
115
T type
ceiling mounted
VRF (ECOi & GHP) Indoor Units
SPW-T...XH
Controller Options
Timer remote controller
The range of ceiling mounted systems
feature a DC fan motor for increased
efficiency and reduced operating sound
levels. All the units are the same height and
depth for a uniform appearance in mixed
installations and feature a fresh air knockout
for improved air quality.
RCS-TM80BG
• Low sound levels
Further comfort improvement
• New design all units just 210mm high
The wide air discharge opening widens the air flow to the left
and the right, so that a comfortable temperature is obtained in
the entire room. The unpleasant feeling caused when the air
flow directly hits the human body is prevented by the “Draft
prevention position”, which changes the swing width, so that
the degree of comfort is increased.
• Easy to install and maintain
• Fresh air knockout 
Simplified remote controller
RCS-TRP80BG.WL
SPW-T...XH
• Large and wide air distribution
Wireless remote controller
Correspondence to ceiling heights up to 4 m
Indoor unit specifications
Model Name
Power source
Cooling capacity
Heating capacity
SPW-T125XH
kW
BTU/h
kW
BTU/h
kW
kW
A
A
Cooling
Heating
Cooling
Running
amperes
Heating
Type
Fan motor
Airflow rate (H/M/L) m³/min
Output
kW
Power sound level (H/M/L)
dB(A)
Pressure sound level (H/M/L)
dB(A)
Height
mm
Dimensions Width
mm
Depth
mm
Liquid (flare)
mm
Piping
Gas (flare)
mm
connections
Drain piping
Net weight
kg
Power
input
3,6
12000
4,2
14000
0,028/0,029/0,029
0,028/0,029/0,029
0,26/0,24/0,23
0,26/0,24/0,23
12/10/9,0
46/43/41
35/32/30
RCS-BH80BG.WL
RCS-KR1EG
SPW-T165XH
SPW-T185XH
SPW-T255XH
SPW-T365XH
SPW-T485XH
220/230/240V, 1 phase - 50, 60 Hz
4,5
5,6
7,3
10,6
14,0
15000
19000
25000
36000
47800
5,0
6,3
8,0
11,4
16,0
17000
21000
27000
39000
54600
0,039/0,029/0,028
0,031/0,032/0,032
0,043/0,043/0,044
0,073/0,074/0,075
0,085/0,086/0,088
0,029/0,029/0,028
0,031/0,032/0,032
0,042/0,042/0,043
0,072/0,073/0,074
0,084/0,085/0,086
0,26/0,24/0,23
0,28/0,26/0,24
0,38/0,35/0,33
0,62/0,57/0,53
0,69/0,63/0,60
0,26/0,24/0,23
0,28/0,26/0,25
0,38/0,35/0,34
0,62/0,57/0,55
0,69/0,63/0,62
Sirocco fan
13/11/9,0
18,5/15/14
27,5/23/20
30/26/22
0,03
0,04
0,08
47/44/41
49/47/44
52/49/46
54/51/48
36/33/30
38/36/33
41/38/35
43/40/37
210
910
1180
1595
680
6,35
9,52
12,7
15,88
VP-20
21
25
33
Specifications subject to change without notice.
Air distribution is automatically altered depending on the
operational mode of the unit.
F1
F2
60°
F3
Heating: F1 to F3
F4
F5
116
Cooling: F1 to F3
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
R410A
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
117
K type
wall mounted
VRF (ECOi & GHP) Indoor Units
SPW-K...XH
Controller Options
Timer remote controller
Wireless remote controller
Simplified remote controller
RCS-TM80BG
RCS-SH1BG
RCS-KR1EG
The K Type wall mounted unit has a stylish
smooth panel which not only looks good but
is even easier to clean.
The unit is also smaller, lighter and
substantially quieter than previous models
making it ideal for small offices and other
commercial applications.
SPW-K...XH
Closed discharge port
Washable front panel
When the unit is turned off, the flap closes completely to
prevent entry of dust into the unit and to keep the equipment
clean.
The indoor unit’s front panel can be easily removed and washed
for trouble-free cleaning.
Cooling
Heating
Cooling
Running amperes
Heating
Power sound level (H/M/L)
Sound pressure level (H/M/L)
Type
Fan motor
Airflow rate (H/M/L)
Output
Air circulation (H/M/L)
Dimensions (HxWxD)
Liquid (flare)
Piping connections Gas (flare)
Drain piping
Net weight
Power input
The width has been decreased by 17% and the units
are lighter.
NEW
255mm
(Current
285mm)
Air distribution is automatically altered depending on the
operational mode of the unit
F1
Quiet operation
These units are among the quietest in the industry, making
them ideal for hotels and hospitals.
Cooling capacity
Heating capacity
Lighter and smaller units make the installation easy
NEW
825 mm
(Current 995mm)
Indoor unit specifications
Indoor Unit
Power Source
F2
SPW-K075XH
kW
BTU/h
kW
BTU/h
kW
kW
A
A
dB(A)
dB(A)
m3/min
kW
m3/hr
mm
mm (inches)
mm (inches)
kg
2,20
7500
2,50
8500
540/450/360
285x825x217
RCS-BH80BG.WL
SPW-K095XH
SPW-K125XH
220/230/240V, 1 phase - 50, 60Hz
2,80
3,60
9600
12000
3,20
4,20
11000
14000
0,018/0,019/0,019
0,020/0,021/0,022
0,019/0,019/0,020
0,021/0,022/0,022
0,16/0,16/0,16
0,19/0,19/0,20
0,17/0,17/0,18
0,20/0,20/0,20
46/43/39
48/44/40
35/32/28
37/33/29
Sirocco fan
9/7,5/6
10/8,5/6,5
0,047
540/450/360
600/510/390
285x825x217
285x825x217
6,35 (1/4)
12,7 (1/2)
VP-13
10
Specifications subject to change without notice.
90°
F3
F4 F5
Heating: F1 to F5
Cooling: F1 to F3
Smooth and hardwaring design
The smooth cover means these units match most modern
interiors. Their compact size enables them to blend in, even
in small spaces.
Anti-mould filters are standard
Piping outlet in three directions
Important
When an indoor unit is installed in a quiet place such as a hotel meeting room, bedroom or
VIP room, the Electronic Expansion Valve may be noisy during cooling and heating operation.
In order to prevent the noise, an optional External Electronic Expansion Valve Kit (ATKSVRK160AGB) can be installed in a narrow tube 5 to 15m away from the indoor unit.
Piping outlet is possible in the three directions of rear, right,
and left, making the installation work easier.
R410A
118
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
119
KR type
wall mounted
VRF (ECOi & GHP) Indoor Units
SPW-KR...GXH56B
Controller Options
Timer remote controller
Wireless remote controller
Simplified remote controller
The slim line designed KR type Wall Mounted is
small and light, making it ideal for commercial
applications. It is also available in a wide variety
of capacities.
RCS-TM80BG
SPW-KR...GXH56B
• Smart colour and round-shape design with horizontal stripes
Washable front panel
• Piping outlet in 3 directions
The indoor unit’s front panel can be easily removed and washed
for trouble-free cleaning.
• Anti-mould filters are standard equipment
The width has been decreased by 17% and the units
are lighter.
NEW
255mm
(Current
285mm)
Piping outlet in three directions
Piping outlet is possible in the three directions of rear, right, and
left, making the installation work easier.
Anti-mould filters are standard
kW
BTU/h
kW
BTU/h
kW
kW
A
A
Cooling
Heating
Cooling
Running
amperes
Heating
Type
Airflow rate (H/M/L)m³/min
Fan motor
Output
kW
Power sound level (H/M/L)
dB(A)
Pressure sound level (H/M/L)
dB(A)
Height
mm
Dimensions Width
mm
Depth
mm
Liquid (flare)
mm
Piping conGas (flare)
mm
nections
Drain piping
Net weight
kg
Power input
Closed discharge port
Lighter and smaller units make the installation easy
Cooling capacity
Heating capacity
• O
ptional external electronic expansion valve kit
ATK‑SURK160AGB prevent noise in quiet rooms and bed
rooms
When the unit is turned off, the flap closes completely to
prevent entry of dust into the unit and to keep the equipment
clean.
Indoor unit specifications
Model Name
Power source
RCS-SH1BG
SPW-KR74GXH56B
SPW-KR94GXH56B
2,2
7500
2,5
8500
2,8
9600
3,2
11000
10/8/6,0
0,011
RCS-BH80BG.WL
RCS-KR1EG
SPW-KR124GXH56B
SPW-KR164GXH56B
SPW-KR184GXH56B
SPW-KR254GXH56B
220/230/240V, 1 phase - 50, 60 Hz
3,6
4,5
5,6
7,3
12000
15000
19000
25000
4,2
5,0
6,3
8,0
14000
17000
21000
27000
0,031/0,033/0,035
0,049/0,052/0,055
0,031/0,033/0,035
0,049/0,052/0,055
0,15/0,15/0,15
0,23/0,23/0,24
0,15/0,15/0,15
0,23/0,23/0,24
Cross flow fan
12/10/8,0
16/14/10
0,015
0,023
47/43/39
53/49/46
36/32/28
42/35/38
285
330
995
1140
203
228
6,35
9,52
12,7
15,88
VP-13
14
21
Specifications subject to change without notice.
Important
When an indoor unit is installed in a quiet place such as a hotel meeting room, bedroom or
VIP room, the Electronic Expansion Valve may be noisy during cooling and heating operation.
In order to prevent the noise, an optional External Electronic Expansion Valve Kit (ATKSVRK160AGB) can be installed in a narrow tube 5 to 15m away from the indoor unit.
NEW
825 mm
(Current 995mm)
Quiet operation
These units are among the quietest in the industry, making
them ideal for hotels and hospitals.
R410A
120
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
121
FR type
floor standing
VRF (ECOi & GHP) Indoor Units
SPW-FR...GXH56B
Controller Options
Timer remote controller
Wireless remote controller
Simplified remote controller
The compact floor standing FR units are the ideal
solution for providing perimeter air conditioning.
The standard wired controller can be incorporated
into the body of the unit.
SPW-FR...GXH56B
• Pipes can be connected to either side of the unit from
the bottom or rear
Effective perimeter handling
• Easy to install
RCS-TM80BG
Indoor unit specifications
Model Name
Power source
Cooling capacity
• Front panel opens fully for easy maintenance
Heating capacity
• Removable air discharge grille gives flexible air flow
A standard wired remote control can be installed
in the body.
kW
BTU/h
kW
BTU/h
kW
kW
A
A
Cooling
Heating
Cooling
Running
amperes
Heating
Type
Fan motor Airflow rate (H/M/L)m³/min
Output
kW
Power sound level (H/M/L)
dB(A)
Pressure sound level (H/M/L) dB(A)
Dimensions (HxWxD)
mm
Liquid (flare)
mm
Piping conGas (flare)
mm
nections
Drain piping
Net weight
kg
Power
input
• Room for condensate pump
SPW-FR74GXH56B
SPW-FR94GXH56B
2,2
2,8
7500
9800
2,5
3,2
8500
11000
0,051/0,056/0,061
0,036/0,040/0,045
0,24/0,25/0,26
0,17/0,18/0,19
7/6/5
0,01
44/41/39
33/30/28
RCS-BH80BG.WL
SPW-FR124GXH56B
SPW-FR164GXH56B
220/230/240 1 phase - 50, 60 Hz
3,6
4,5
12000
15000
4,2
5,0
14000
17000
0,079/0,085/0,091
0,116/0,126/0,136
0,064/0,070/0,076
0,079/0,091/0,101
0,37/0,38/0,39
0,54/0,56/0,58
0,30/0,31/0,32
0,37/0,41/0,43
Sirocco fan
9/7/6
12/9/8
0,02
0,02
50/46/40
49/46/42
39/35/29
38/35/31
615x1065x230
6,35
12,7
RCS-KR1EG
SPW-FR184GXH56B
SPW-FR254GXH56B
5,6
19000
6,3
21000
0,116/0,126/0,136
0,079/0,091/0,101
0,54/0,56/0,58
0,37/0,41/0,43
7,1
24000
8,0
27000
0,150/0,160/0,170
0,110/0,120/0,130
0,70/0,72/0,73
0,52/0,54/0,56
15/13/11
0,03
50/47/42
39/36/31
615x1380x230
17/14/12
0,06
52/49/46
41/38/35
9,52
15,88
VP-20
29
39
Specifications subject to change without notice.
R410A
122
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
123
FMR type
concealed floor standing
VRF (ECOi & GHP) Indoor Units
SPW-FMR...GXH56B
Controller Options
Timer remote controller
Wireless remote controller
Simplified remote controller
At just 229mm deep, the FMR unit can be
easily concealed in perimeter areas to provide
powerful and effective air conditioning.
SPW-FMR...GXH56B
• Chassis unit for discrete installation
Perimeter air conditioning with high interior quality
• Complete with removable filters
• P
ipes can be connected to either side of the unit
from the bottom or rear
• Easy to install
RCS-TM80BG
Indoor unit specifications
Model Name
Power source
Cooling capacity
Heating capacity
SPW-FMR74GXH56B
kW
BTU/h
kW
BTU/h
kW
kW
A
A
Cooling
Heating
Cooling
Running
amperes
Heating
Type
Fan motor Airflow rate (H/M/L)m³/min
Output
kW
Power sound level (H/M/L)
dB(A)
Pressure sound level (H/M/L) dB(A)
Dimensions (HxWxD)
mm
Liquid (flare)
mm
PipingconGas (flare)
mm
nections
Drain piping
Net weight
kg
Power
input
SPW-FMR94GXH56B
2,2
2,8
7500
9800
2,5
3,2
8500
11000
0,051/0,056/0,061
0,036/0,040/0,045
0,24/0,25/0,26
0,17/0,18/0,19
7/6/5
0,01
44/41/39
33/30/28
RCS-BH80BG.WL
SPW-FMR124GXH56B
SPW-FMR164GXH56B
220/230/240 1 phase - 50, 60 Hz
3,6
4,5
12000
15000
4,2
5,0
14000
17000
0,079/0,085/0,091
0,116/0,126/0,136
0,064/0,070/0,076
0,079/0,091/0,101
0,37/0,38/0,39
0,54/0,56/0,58
0,30/031/0,32
0,37/0,41/0,43
Sirocco fan
9/7/6
12/9/8
0,02
0,02
50/46/40
49/46/42
39/35/29
38/35/31
616x904x229
6,35
12,7
RCS-KR1EG
SPW-FMR184GXH56B
SPW-FMR254GXH56B
5,6
19000
6,3
21000
0,116/0,126/0,136
0,079/0,091/0,101
0,54/0,56/0,58
0,37/0,41/0,43
7,1
24000
8,0
27000
0,150/0,160/0,170
0,110/0,120/0,130
0,70/0,72/0,73
0,52/0,54/0,56
15/13/11
0,03
49/46/42
39/36/31
616x1219x229
17/14/12
0,06
52/49/46
41/38/35
9,52
15,88
VP-20
21
28
Specifications subject to change without notice.
R410A
124
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
125
GU type
Total Heat Exchanger
VRF (ECOi & GHP) Indoor Units
SPW-GU...XH
Controller Options
Timer remote controller
Wireless remote controller
Simplified remote controller
SANYO’s new heat recovery ventilation system
allows total control via a system network whilst
modulating the temperature and humidity of
incoming air supply.
RCS-TM80BG
SPW-GU...XH
• Integration of heat recovery ventilation and DX coil
technology for optimum air temperature control
• Compact design
• Humidifier & filter option
• T he DX coil can be connected to all ECO & GHP
outdoor units
• 3 Way: Solenoid valve kit is required for each unit
• Humidifying function available as an option
• 2 Way: RAP kit is required for each unit
• Easy to clean filter
Indoor unit specifications
Model Name
Air circulation (H) m³/h
Power source
Fresh air load treat- Cooling
ment capacity
Heating
Enthalpy Exchange Cooling
Efficiency
Heating
Temp exchange efficiency
Equivalent cooling capacity
OA
Intake grille
RA
R
EA
*Reduce pressure valve
*Stop valve for water supply
SA
Distribution chamber
*Water supply line
Inlet
R
SA
B
Outlet
RA
EA
B
OA
Rap valve kit
ATK-RX160AGB
126
Rap valve kit
A
A
kW
kW
%
%
kW
BTU/h
kW
kW
A
A
5,3 (1,7)*¹
6,5 (2,3)*¹
3,6
12000
0,532/0,532/0,532
0,532/0,532/0,532
2,5/2,4/2,3
2,5/2,4/2,3
Cooling
Heating
Cooling
Running amperes
Heating
Type
External static pressure-return air
Pa
183 (170)
Fan motor
External static pressure-supply air Pa
205 (182)
Output
kW
0,28 (4P)x2
Power sound level (C/H)
dB(A)
57 (Cooling), 58 (Heating)
Pressure sound level (C/H)
dB(A)
46 (Cooling), 47 (Heating)
Height mm
425
Dimensions
Width mm
1785
Depth mm
1000
Liquid (flare)
mm (inches)
Piping connections Gas (flare)
mm (inches)
Drain piping
Connection duct diameter
mm
Net weight
kg
134
The values in ( ) for the external static pressure and operating sound are for use of booster cable.
*1: Heat recovery capacity by heat exchanger.
Power input
System Outline
SPW-GU055XH
500
RCS-BH80BG.WL
RCS-KR1EG
SPW-GU075XH
SPW-GU105XH
750
1000
220/230/240V, 1 phase - 50 Hz
8,2 (2,6)*¹
10,7 (3,4)*¹
9,8 (3,5)*¹
12,6 (4,6)*¹
59
67
75
5,6
7,3
19000
25000
0,737/0,737/0,737
0,798/0,798/0,798
0,737/0,737/0,737
0,798/0,798/0,798
3,4/3,2/3,1
3,7/3,5/3,4
3,4/3,2/3,1
3,7/3,5/3,4
Sirocco fan
221 (188)
135 (88)
264 (218)
176 (137)
0,35 (4P)x2
58 (Cooling), 59 (Heating)
59 (Cooling), 60 (Heating)
47 (Cooling), 48 (Heating)
48 (Cooling), 49 (Heating)
450
1903
1120
1220
6,35 (1/4)
12,7 (1/2)
VP-25
250
300
153
168
Specifications subject to change without notice.
Using duct unit for supply and
circulation air
Using duct unit for supply air
using back of ceiling for circulation air
*These valves and line is necessary only when humidification is used.
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
127
Convenient System Control
for VRF (ECOi & GHP) and PACi
Convenient System Control
A wide variety of
control options
Operation system
Requirements
Normal
operation
Individual control systems
Timer operation
Operation from
each seat
Daily and
weekly program
Simple operation
Operation system
Requirements
Centralised control systems
Operation with various function
from central station
Only ON/OFF operation from
central station
Simplified charge ratio for each tenant
Touch screen panel
Personal computer (field supply)
External appearance
External appearance
Web application
Type, model name
Numberofindoorunitswhichcanbe
controlled
Timer wired
remote controller
RCS-TM80BG
Wireless remote
controller
RCS-SH80BG.WL
RCS-SS80BG.WL
RCS-BH80BG.WL
RCS-TRP80BG.WL
RCS-SH1BG
RCS-XM18BG.WL
Simplified remote controller
RCS-KR1EG
Schedule timer
SHA-TM64AGB
1 group, 8 units
1 group, 8 units
1 group, 8 units
64 groups,
max. 64 units
Type, model name
Number of indoor units
which can be controlled
Use limitations
Up to 2 units can be
connected per group.
Up to 2 units can be
connected per group.
Up to 2 units can be
connected per group.
Power supply from the system
controller.
When there is no system controller,
connection is possible to the T10
terminal of an
indoor unit.
Connectable indoor unit
4/5 series indoor unit
4/5 series indoor unit
4/5 series indoor unit
4/5 series indoor unit




*1




*1




*1
—
ON/OFF
—
Mode setting
—
Fan speed setting
—
Temperature setting
—
Air flow direction
Permit/Prohibit switching
—
—
—
—
Permit/Prohibitswitching
Weekly program

—
—

Weekly program
Mode setting
Fan speed setting
Temperature setting
Air flow direction
*1 Setting is not possible when a remote control unit is present. (Use the remote control for setting.)
128
Connectable indoor unit
ON/OFF controller
SHA-KC16KAGB
Intelligent controller
SHA-KT256EG
Communication adaptor
SHA-KA128AGB
64 groups,
max. 64 units
16 groups,
max. 64 units
64 units x 4 networks,
max. 256 units
2 systems,
max. 128 units
Up to 10 units can be connected
to one system.
Main unit/sub unit (1 main unit +
1 sub unit) connection is possible.
Use without remote controller is
possible.
Upto8units(4mainunits+4subunits)
can be connected to one system.
Use without remote controller is
impossible.
A communication adaptor
(SHA-KA128AGB)mustbeinstalledfor
three or more networks.
4/5 series indoor unit
4/5 series indoor unit
4/5 series indoor unit
4/5 series indoor unit





*1

—
—





*1






*1

Function
Function
ON/OFF
Use limitations
System controller
SHA-KC64AGB
—
—
—
—

All specifications subject to change without notice.
129
Individual Control Systems
Convenient System Control
Control contents
Part name, model No.
Standard Control
• Controlofthevariousoperationsoftheindoor
unit by wired or wireless remote controller.
• Coolingorheatingmodeoftheoutdoorunit
is decided by the first priority of the remote
controller.
• Switchingbetweenremotecontrollersensor
and body sensor is possible.
1 unit each
Timer remote controller
RCS-TM80BG
Wireless remote controller
RCS-XM18BG.WL
RCS-SH80BG.WL
RCS-SS80BG.WL
RCS-BH80BG.WL
RCS-TRP80BG.WL
RCS-SH1BG
RCS-KR1EG
Wireless remote controller
Quantity
(1) Group control
• Batch remote control on all indoor units.
• Operation of all indoor cells in the same mode.
• Up to 8 units can be connected.
• The sensor is the body sensor, and thermostat
ON/OFFsettinginregardtothetemperatureset
by the remote controller is possible for each
indoor unit.
Timer remote controller
RCS-TM80BG
RCS-KR1EG
(2) Main/sub remote control
• Max 2 remote controllers per indoor unit.
(Mainremotecontrollercanbeconnected)
• The button pressed last has priority.
• Timer setting is possible even with the sub
remote controller.
As required
Main or sub
Timer remote controller
RCS-TM80BG
Wireless remote controller
RCS-XM18BG.WL
RCS-SH80BG.WL
RCS-SS80BG.WL
RCS-BH80BG.WL
RCS-TRP80BG.WL
RCS-SH1BG
RCS-KR1EG
System example ECOi/GHP
Easy installation for the 4-way cassette type simply by
replacing the corner part
24 hour timer function
RCS-BH80BG.WL
1 unit
Remote controller
Standard
control
Main Sub
(2) Main/sub
remote control
Main
Sub
XM type
RCS-XM18BG.WL
RCS-BH80BG.WL
X type
RCS-SH80BG.WL
RCS-BH80BG.WL
XMR, SR, FTR types
RCS-SS80BG.WL
(1) Group control
RCS-BH80BG.WL
RCS-BH80BG.WL
ADR, T, LDR types
RCS-TRP90BG.WL
System example PACi
K type
RCS-SH1BG
For all indoor units
RCS-BH80BG.WL
Ventilation independent operation is possible
When commercial ventilation fans or heat-exchange ventilation
fans have been installed, they can be operated with this
remote control (interlocked operation with the indoor unit or
independent ventilation ON/OFF)
Timer remote controller (RCS-TM80BG)
Time Function 24 hours real time clock
• Operation mode changeover (Cooling, Heating, Dry,
Auto, Fan)
• Temperature setting (Cooling/Dry: 18-30 deg Heating:
16-30 deg)
• Air volume adjustment (HH, H, LL, Auto).
• Air flow direction adjustment
• This function can prevent the room temperature from
dropping or rising when the occupants are out for a long time
Dimensions H 120 x W 70 x D 16 mm
• This function controls the room temperature for comfortable
sleeping.
Remote control by main remote controller and sub
controller is possible
Max. 2 remote controllers (main remote controller and sub
controller) can be installed for one indoor unit
• When a separate receiver is set up in a different room, control
from that room also becomes possible
• Automatic operation by means of the emergency operation
button is possible even when the remote controller has been
lost or the batteries have been exhausted
I n addition, there are other functions such as temperature
setting, operation switching, wind direction/fan speed
setting, etc.
• ON/OFF, operation mode switching, temperature setting,
wind velocity switching, wind direction setting, alarm
display, and remote controller
self-diagnosis can be performed.
Outing Function
Max. 8 indoor units can be controlled from one remote
controller.
hen RCS-BH80BG.WL is used, wireless control becomes
W
possible for all indoor units
• Suitable for open rooms or hotels where detailed functions
are not required.
• A maximum of 6 actions can be programmed for each day
Sleeping Function
• Do not perform group control for 3 Series indoor units and
4 Series indoor units together
A remote controller with simple functions and basic operation.
Weekly Programme Function
Basic remote controller ON/OFF
• Max. 2 remote controllers (main remote controller and sub
controller) can be installed for one indoor unit
Simplified remote controller (RCS-KR1EG)
• Day of the week indicator
Dimensions
H 120 x W 120 x D 16mm
Remote control by main remote controller and sub
controller is possible
Remote sensor (ART-K45AGB)
• Batch group control for up to 8 indoor units.
• Remote control by main remote controller and sub controller
is possible with a simplified remote controller or a wired
remote controller (up to two units).
• T his is a remote sensor which can be used with 4 series
indoor units. Please use it to detect the room temperature
when no remote controller sensor or body sensor is used.
(Correspondence to a system without a remote controller is
possible.)
• F or joint use with a remote control switch, use the remote
control switch as main remote controller
130
131
Centralised Control Systems
Centralised Control Systems
Schedule timer (RCS-TM64AGB)
ON/OFF controller (SHA-KC16KAGB)
Up to 64 groups (max. 64 indoor units) can be controlled
divided into 8 timer groups
Six program operations (Operation/Stop/Local permission/
Local prohibition) per day can be set in a program for one week
• O
nly operation or stop, remote controller local permission
or remote controller local prohibition, and their respective
combinations are possible. (Operation + local permission,
stop + local prohibition, only local permission, etc.)
Dimensions
H 120 x W 120 x D 16 mm
The power supply for the schedule timer is taken from one of
the following
1 Control circuit board (T10) of a nearby indoor unit (power
supply wiring length: within 200 m from the indoor unit)
2 System controller (power supply wiring length: within 100 m
from the indoor unit)
hen the power supply for the schedule timer is taken from the
W
control circuit board of the indoor unit, that indoor unit cannot be
used with other control devices using the T10 terminal.
• 16 groups of indoor units can be controlled
Dimensions H 121 x W 122 x D 14 + 52
(embedding dimension mm)
Power supplyAC 220 to 240 V
I/O partRemoteinput(effectivevoltage:
within DC 240V): All ON/OFF
Remoteoutput(allowablevoltage:
within DC 30V): All ON, All alarm
• Collective control and individual group (unit) control can also
be performed
• Up to 8 ON/OFF controller (4 main, 4 sub) can be installed in
one link system
• The operation status can be determined immediately
Note: As operation mode and temperature settings are not possible with the ON/OFF controller, it must be used together with a remote controller a system controller etc
• L ocal prohibition and the combination of the three items of
temperature setting, mode change, and operation/stop can
be set at the time of installation
A function for pausing the timer in case of national
holidays has been added, and timer operation also can be
stopped for a long time
• By setting holidays or operation stop within one week, the
timer can be paused just for that week.
• A
ll timer settings can be stopped with the timer “ON/OFF
effective” button. (Return to timer operation is made by
pressing the button again.)
s operation mode and temperature settings are not possible
A
with the schedule timer, it must be used together with a remote
controller, a system controller, an intelligent controller, etc. Also, as
it does not have an address setting function, the control function
of a system controller etc. must be used for address setting
Connection example 1
(power supply from the indoor unit)
Connection example 2
(power supply from the central controller)
Connection example 2 (power supply from the central controller)
Indoor/outdoor
operation wire
System controller Schedule timer
Indoor/outdoor
operation wire
System controller
Zone 1
Centralised addresses
1 to 16
Schedule timer
1
2
8
Timer group 1: Centralized addresses 1 to 8
Zone 1
Centralised addresses
1 to 16
1
2
8
Timer group 1: Centralised addresses 1 to 8
9
10
17
18
24
Timer group 2: Centralised addresses 9 to 16
25
26
Zone 2
Centralised addresses
17 to 32
17
18
24
Zone 3
Centralised addresses
33 to 48
33
34
40
Timer group 5: Centralized addresses 33 to 40
Remote controller Schedule timer
33
34
40
41
42
Zone 1
Centralised addresses
49 to 64
49
50
56
Timer group 7: Centralized addresses 49 to 56
49
50
56
57
58
Timer group 2: Centralized addresses 9 to 16
25
26
32
Timer group 4: Centralized addresses 25 to 32
41
42
48
Timer group 6: Centralized addresses 41 to 48
48
Timer group 5: Centralised addresses 33 to 40 Timer group 6: Centralised addresses 41 to 48
Zone 4
Centralised addresses
49 to 64
16
32
Timer group 3: Centralised addresses 17 to 24 Timer group 4: Centralised addresses 25 to 32
Zone 3
Centralised addresses
33 to 48
10
16
Timer group 3: Centralized addresses 17 to 24
Zone 2
Centralised addresses
17 to 32
9
57
58
64
Timer group 8: Centralized addresses 57 to 64
64
Timer group 7: Centralised addresses 49 to 56 Timer group 8: Centralised addresses 57 to 64
132
133
Centralised Control Systems
Centralised Control Systems
System controller (SHA-KC64AGB)
Intelligent controller (SHA-KT256EG)
A control mode corresponding to the use condition can be
selected from 10 patterns
AOperation mode: Central control mode or remote control
mode can be selected
Central control mode: The system controller is used as
centralised control device. (Setting from a remote controller
can be prohibited by prohibiting local operation from the
system controller.)
Remote control mode: The system controller is used as a
remote controller. (Setting from the system controller can be
prohibited by prohibiting local operation from another central
control unit.)
Dimensions
160 x W 160 x D 21 + 69 (embedding dimension) mm
Power supply
AC 220 to 240 V
I/O partRemote input (effective voltage: DC 24 V): All ON/All OFF
Remote output (voltage-free contact): All ON/All OFF
(external Power supply within DC 30 V)
Total wiring length1km
BControlled unit number mode: All mode or zone 1, 2, 3, 4
mode can be selected
All mode: All, zone, or group unit can be selected.
Zone 1, 2, 3, 4 mode: Setting is possible only for the indoor
units of zone 1, 2, 3, or 4.
A Operation mode
Control of 64 indoor units divided into 4 zones. (One zone can
have up to 16 groups, and one group can have up to 8 units.)
Control is possible for ON/OFF, operation mode, fan speed, air
flow direction (only when used without a remote controller),
operation monitoring, alarm monitoring, ventilation, remote
controller local operation prohibition, etc
All mode
B
Zone 1 mode
Controlled
Zone 2 mode
unit
number
mode
Zone 3 mode
Zone 4 mode
IndividualAll operations are possible also from the remote
controller. However, the contents will be changed
to the contents of the controller operated last
Central 1The remote controller cannot be used for ON/OFF.
(All other operations are possible from the remote
controller.)
Central 3The remote controller cannot be used for mode
change or temperature setting change. (All other
operations are possible from the remote controller.)
Central 4The remote controller cannot be used for operation
mode change. (All other operations are possible
from the remote controller.)
Central control mode
Remote control mode
All central control
Example 1
All remote control
Zone 1 central control
Example 2
Zone 1 remote control
Zone 2 central control
Zone 2 remote control
Example 3
Zone 3 central control
Example 4
Zone 3 remote control
Zone 4 central control
Zone 4 remote control
Example 5
System controller
(Control mode example 2: Central control for zone 1)
Use of a schedule timer and holiday setting also can be done
Proportional distribution of the air-conditioning energy is
possible
Dimensions
H 240 x W 280 x D 138 mm
Power supplyAC 100 to 240 V (50 Hz), 20 W (separate power supply)
I/O partRemote in put (voltage-free contact): All ON/OFF
Remote output (voltage-free contact): All ON, All alarm
(external power supply within DC 30 V)
Total wiring length 1 km for each system
Only for embedding in the panel
Prohibition means limitation of the operation contents from the
remote controller. It is also possible to change the prohibition items.
Limitation contents
IndividualThere is no limitation for the operation of the
remote controller. However, the contents will
be changed to the contents of the controller
operated last. (Last-pressed priority.)
Prohibition 1The remote controller cannot be used for
ON/OFF. (All other operations are possible from
the remote controller.)
Prohibition 2The remote controller cannot be used for
ON/OFF, operation mode change and
temperature setting. (All other operations are
possible from the remote controller.)
Prohibition 3The remote controller cannot be used for
operation mode change and temperature
setting. (All other operations are possible from
the remote controller.)
Prohibition 4The remote controller cannot be used for
operation mode change. (All other operations
are possible from the remote controller.)
NEW function: Pulse signal input from electric/gas
consumption meter
In case of joint use with a wireless remote control system, there are limitations for the control
mode. Please use only with “Permission” and “Prohibition 1”
Web application
Linked system No. 1
Intelligent
controller
SHA-KT256EG
System signal x 4
Linked system No. 2
RS 485
(Polarity shield wire)
Linked system No. 3
Communication
adapter
SHA-KA128AGB
Linked system No. 4
System signal x 4
System controller
Group control
(Control mode example 3: Remote control for zone 2)
Max. 256 indoor units (4 systems x 64 units) can be controlled. In case of three or more systems, a communication
adapter SHA-KA128AG must be installed on the outside
Operation is possible as batch, in zone units, in tenant
units and in group units
(The maximum number of connectable system controllers is 10,
including other central controllers on the same circuit.)
System controller
(Control mode example 4: Central control for zone 3)
(In case of joint use with a wireless remote controller, there
are limitations for the control mode. Please use only with
“Individual” and “Central 1”.)
Individual remote controller
System controller
System without a remote controller
Control of a group
without remote controller
(Control mode example 1:
All central control)
Display sample
Max. 4 links can be connected for the
indoor/outdoor operation line
= Max. 64 indoor units x 4 (256 units)
Max. 30 outdoor units x 4 (120 units)
Communication adaptor (SHA-KA128AGB)
For more information on
how to connect please see
installation manual.
(Control mode example 5: Remote control for zone 4)
System controller
134
Individual
remote controller
A system without a remote controller is possible. Joint use
with a remote controller or a system controller is also possible
Note: Avoid joint use of the AMY system and the intelligent controller on the same indoor/
outdoor operation line
Joint use with a remote controller, an intelligent controller,
a schedule timer, etc. is possible
Control of systems without a remote controller and of
main/sub systems (a total of up to 2 units) is possible
Touch panel
Limitation contents for prohibited operation
Connection example
Individual control is possible for max. 64 groups, 64 indoor
units.
ON/OFF, operation mode setting, temperature setting, for
fan speed setting, air flow direction setting (when used
without a remote controller), and remote controller local
operation prohibition (prohibition 1, 2, 3, 4) can be done
Dimensions
Power supply
H 260 x W 200 x D 68 mm
AC 100 to 240 V (50 Hz),
3 W (separate power supply)
Required to connect three or more linked wiring systems
(indoor/outdoor operation lines) to the intelligent
controller
Also required for connection of the AMY software
T wo linked wiring systems can be connected to one SHAKA128AG, but max. 4 systems can be connected for the
entire intelligent controllers
*As this is not a splash-proof design, it must be installed indoors or in the control panel etc
135
Interfaces for external Control
Convenient System Control
Seri-Para I/O unit (ACC-SP16TAGB)
MINI Seri-Para I/O Unit (ACC-SP1AGB)
• This is the interface for connecting signals from the central
control device with the SANYO air conditioner unit control
network
• Power is supplied from the T10 terminal of the indoor units
• Separate power supply also is possible (in case of suction
temperature measuring)
• This unit can control and monitor the status up to 16 groups
of indoor units (max 64 indoor units)
System example
• Up to 4 seri-para units can be connected in one system
• From the central control device, it is possible to set the
temperature and to monitor the room temperature or intake
air temperature
System example
• In addition to operation and stop, there is a digital input
function for air speed and operation mode
LonWorks interface (SHA-LN16UGB)
• This interface is a communications converter for connecting
LonWorks to the SANYO air conditioner unit (PAC, ECOi,
GHP) control network
• From the host connected to LonWorks, basic settings and
status monitoring is possible for up to 16 groups of A/C units
Seri-Para I /O unit for outdoor unit (ACC-XSP4U1GB)
Center Control Device
Dimensions H 80 x W 290 x D 260 mm • This unit can control up to 4 outdoor units.
Power supply Singlephase100/200V(50/60
• From the centre control device, mode changing and batch
Hz), 18W
operation/batch stop are possible
Input Batch operation/Batch stop
(non-voltage contact/DC 24V,• Required for demand control.
pulse signal)
Cooling/Heating
(non-voltage contact/static System example
signal)
Demand 1/2
Seri-para I/O
(non-voltage contact/static
signal)(Localstopbyswitching)
Output Operation output
(non-voltage contact)
Alarm output
(non-voltage contact)
Wiring length Indoor/Outdooroperationlines:
Total length 1km
Digital signal:
100m or shorter
• C
ontrol and status
monitoring is possible
for individual indoor
unit by contact signal.
System example
SHA-KL4UGB
ON/OFF
controller
Functions
System example
Indoor/outdoor unit
control line
LON
System Controller
LonWorks interface
LON
LonWorks
communication line
Centre Control
Device
System example
Start/stop
Temp. setting
Settings for
A/Cunitsettingsfrom each group of
Operation mode
the LonWorks com- indoor units
Option 1 settings*
municator
Option 2 settings*
Settings for all units Emergency stop
Start/stop
Temp setting
Operation mode
Option 1 settings*
A/C unit status notifications made to
Option 2 settings*
the LonWorks communicator
Alarm status
Indoor units with active alarms
Room temperature
A/C unit status
Transmission intervals settings
Configuration properties
Minimum time secured for transmission
* Selecttwoofthefollowing:remotecontrollerprohibit,fanspeedsetting,airdirectionsetting,
filter sign reset.
Signal output board (ACC-SG-AGB)
Local adaptor for ON/OFF control (SHA-KL4UGB)
136
Central control panel
• The analog input for temperature setting is 0 to 10 V
Central Control Device
ON/OFF (Pulse DC24V)
Local prohibit (Continuous DC24V)
Temp setting (Analog DC1~5V)
All ON/OFF (Pulse DC24V)
All local prohibit & emergency stop (Continuous DC24V)
On/Alarm/Answer back/Filter sign
Room temp (Analog DC4-20mA)
All ON/OFF
ACC-SP1AGB
• Temperature setting and measuring of the indoor suction
temperature can be performed from central monitoring
Seri-para I/O
Input
Output
Remote
station
• Control and status monitoring is possible for individual indoor
unit (1 group)
• Defrost, heating, cooling and thermostat ON signal can be
put out to the outside.
• S ignal type (2 types): Voltage specification, non-voltage
specification
For example:
fan coil unit etc.
total heat exchanger unit.
137
BMS Software
Convenient System Control
STAIMS Basic software TECS-5000
AMY Software
An air conditioner
central control system for buildings
AMY software is an air conditioner (A/C) central control system for buildings
SANYO Total Air conditioning Intelligent Management System
Up to 1024 indoor units can be controlled by 1 PC
RS485/RS232C
Adaptor
(Field supply)
(RS-232C)
Communication
adaptor
Functions for basic software
• Standard remote control for all indoor units.
(RS-485)
• Multiple timer schedule programs can be set on the calendar.
Max. 64 I/D
• CSV file output with alarm history, operating status.
Outdoor unit
Group control
communication
adapter
SHA-KA128AG
• Detail information display for alarm happening.
Remote controller
• Automatic data backup to HDD.
By using up to 4 optional software modules a more extensive control is possible.
Outdoor unit
Group control
Remote
controller
TECS-5000A for Load distribution
TECS-5000B for BACnet interface
Load distribution calculation for each
tenant
• Air-con load distribution ratio is
calculated for each unit
(tenant) with used energy
consumption data (m3, kWh).
Connectable to BMS system
• Communicate with other
equipments by BACnet protocol.
• Calculated data is stored with
CSV type file.
• Data of last 365 days will be
stored.
• Up to 256 indoor units can
be connected to 1 PC (that
has STAIMS basic & BACnet
software).
TECS-5000G for Object layout display
TECS-5000WAIMS
for Web
application
is suitable
for large shopping centers and universities with many areas/ building
Whole system can be controlled visually
• Operating status monitor is
available on the layout display.
Web access & control from remote
station
• Accessing STAIMS software
User PC
from remote PC.
• SANYO airconditioners system
can be controled by both BMS
and STAIMS.
Max. 64 I/D
Outdoor unit
Group control
Remote
controller
• Object’s layout and indoor unit’s
location can be checked at once.
Outdoor unit
Max. 16 system
Connectable I/D units: Max. 512
• You can monitor/operate SANYO
system by using Web browser
(Internet Explorer).
• Each unit can be controled by
virtual remote-controller on the
display.
Communication
Adaptor
• Up to 4 layout screens are
shown at once.
Remote
controller
AIMS is suitable for large shopping centers and universities with many areas/ buildings. 1 "ST
AIMS is suitable for large shopping centers and universities
with
many centers
areas/andbuildings.
1 many
"ST areas/ buildings. 1 "ST
AIMS is suitable for
large shopping
universities with
STAIMS is suitable for large shopping
centers or Universities that have large
User PC
areas/many buildings.
Functions
A/C unit settings
A/C unit status
Unit ON/OFF
Mode-change
Room temperature setting
Fan speed setting
Flap setting
Central control setting
Filter-sign clear
Alarm reset
Unit ON/OFF status
Operation mode
Setting temperature
Fan speed status
Flap status
Central control setting
Filter-sign situation
Correct/incorrect status
Alarm code
Charge calculation rate
Communication
BuildingA
A
Building
Adaptor
User PC
Building A
User PC
1 STAIMS PC can have 4 independent
systems at once. Each system can have
up to 8 C/A units, and control up to 512
units.
In total, 1024 indoor units can be
controlled by 1 STAIMS PC.
Communication
Adaptor
Building B
Communication
Adaptor
Communication
Adaptor
Communication
Adaptor
Communication
Building
B
Adaptor
Building B
• Wiring
AIMS is suitable for large shopping centers and universities with many areas/ buildings.
1 "ST length (PC~C/A) up to 1 km
Software environment
• Up to 8 C/A for 1 system
User PC
OSWindows 2000,
WindowsNT4.0Service
Pack 6 or above
BrowserInternet Explorer 4.0
or above
138
Communication
• Wiring length for each link from C/A
up to 1 km
Building D
Communication
Adaptor A
Building
Communication
Adaptor
Communication
Adaptor
Building D
139
Building D
PAC2 System Design Software
Convenient System Control
PAC2 System Design Software
System designing for VRF (ECOi and GHP) and PACi
Commercial Split Systems has never been easier
SANYO has identified the importance of ever‑increasing
demands for fast and accurate responses to customer requests
in our industry. More and more emphasis is being placed upon
energy-efficiency in our marketplace. The ability to calculate
cooling/heating loads and produce information of actual design
conditions is a major advantage to any architect, consultant,
contractor or end user.
The design package utilises system wizards and import tools
to enable both simple and complex systems to be created.
In addition, the system will allow outdoor and indoor units
to be dragged and dropped on an interactive desktop. This
allows users to create everything from realistic floor plans
with detailed piping and wiring schematics to send out with
quotations, through to installation guidance drawings.
SANYO understands the ever‑changing and demanding industry
we are in and we are pleased to announce the launch of the
next generation of our system design software program. The
advanced PAC2 system design software has been customised
to make any selection and design process as quick and easy
as possible. The software features a version of AC Calc Lite
(produced by Click Software). This allows small building loadings
to be accurately calculated and directly imported into the PAC2
software.
The PAC2 system software can be used for all
SANYO ECOi, GHP and PACi systems.
Features include
• AC Calc Lite (included in the package)
• Easy to use system wizards
• Auto piping and wiring features
• Converted duties for conditions and pipework
• Auto CAD (DXF) export
• Detailed wiring and pipework diagram
The PAC2 system software can be used for all SANYO ECOi, GHP and PACi systems.
140
141
CO2 ECO Heating System
Content
CO2 ECO
Heating
­System
142
CO2 ECO Heating System - Overview 144
SANYO CO2 ECO Tank Unit
150
CO2 ECO Heating Domestic System 152
143
CO2 ECO Heating System
Energy efficient air to water heat pump technology
CO2 ECO Heating System
Key features
• Environmentally friendly R744 (CO2) refrigerant
• High performance DC rotary compressor
• F ree Energy from a renewable source thus a good
alternative to gas and oil
• I nverter control and 3-phase 400V or single phase 230V power
supply
• Choice of 4.5kW and 9.0kW capacity
• High efficiency split cycle (in case of 9kW outdoor unit)
• C
an provide hot water and central heating via radiators
or under floor heating (Sanitary hot water up to 65°C)
• Reliable and rugged design
• Freeze protection circuit
• Performs even in temperatures as low as -25°C
• Highly efficient refrigerant-to-water heat exchanger
• Easy to install and minimum maintanance
SHP-C90GDN/ GEN
SHP-C45DEN
Model No.
System power supply
HP unit
Tank unit
3ph400V-50Hz
SHP-TH45GDN-SW
Performance
*1 Heating capacity/input (Out door temp. 25°C)
*1 COP (Out door temp. 25°C)
*1 Heating capacity/input (Out door temp. 7°C)
*1 COP (Out door temp. 7°C)
*1 Heating capacity/input (Out door temp. -15°C)
*1 COP (Out door temp. -15°C)
*1 Heating capacity/input (Out door temp. -20°C)
1ph-230V-50Hz
SHP-C45DEN
SHP-TH45GEN-SW
3ph-230V-50Hz
SHP-TH45GHN-SW
1,6
Maximum current
HP unit
Tank unit
HP unit
Tank unit
Tank unit
Tank capacity
Maximum working pressure
Maximum working pressure tap water (safety valve)
Auxiliary electric heater capacity
Net H/W/D
Dimensions
Shipment H/W/D
Weight
Net/Shipping
3ph-400V-50Hz
22,5A
9,0kW + 6,0kW
Heat pump unit
Refrigerant/amount
*2 Sound pressure level
Compressor
Dimensions
Weight
Net H/W/D
Shipment H/W/D
Net/Shipping
* 1 Inlet water temperature 30°C, Outlet water temperature 50°C
* 2 Outdoor temperature 7°C Inlet water temperature 30°C, Outlet water temperature 50°C
capacity ratings do not include any defrost operation data
144
9,0kW/2,2kW
4,1
9,0kW/2,9kW
3,1
9,0kW/5,0kW
1,8
8,0kW/5,0kW
1,6
3ph-230V-50Hz
SHP-C90GEN
SHP-TH90GHN-SW
SHP-TH90GEN-SW
1ph-230V-50Hz
9,0kW/2,2kW
4,1
9,0kW/2,7kW
3,3
8,0kW/4,45kW
1,8
7,0kW/4,35kW
1,6
Electrical Ratings
Electrical Ratings
Power supply
3ph-400V-50Hz
SHP-C90GDN
SHP-TH90GDN-SW
Performance
*1 Heating capacity/input (Out door temp. 25°C)
*1 COP (Out door temp. 25°C)
*1 Heating capacity/input (Out door temp. 7°C)
*1 COP (Out door temp. 7°C)
*2 Heating capacity/input (Out door temp. -15°C)
*2 COP (Out door temp. -15°C)
*2 Heating capacity/input (Out door temp. -20°C)
*2 COP (Out door temp. -20°C)
4,5kW/1,1kW
4,1
4,5kW/1,45kW
3,1
4,5kW/2,48kW
1,8
4,0kW/2,5kW
*1 COP (Out door temp. -20°C)
Model No.
System power supply
HP unit
Tank unit
1ph-230V-50Hz
1ph-230V-50Hz
16A
52A
3ph-230V-50Hz
35,4A
223L
2,5bar
10bar (9bar)
6,0kW + 6,0kW
1574mm/596mm/630mm
1736mm/700mm/767mm
155,0kg/200,0kg
7,05kW + 7,05kW
R744 (CO2)/0,86kg
45,0 dB-A
DC Rotary two stage compression
690mm/840mm/290mm
765mm/943mm/433mm
65,0kg/72,0kg
Specifications subject to change without notice.
Power supply
Maximum current
HP unit
Tank unit
HP unit
Tank unit
Tank unit
Tank capacity
Maximum working pressure
Maximum working pressure tap water (Safety valve)
Auxiliary electric heater capacity
Dimensions
Weight
Heat pump unit
Refrigerant/amount
*3 Sound pressure level
Type of Compressor
Dimensions
Weight
3ph-400V-50Hz
3ph-400V-50Hz
10A
22,5A
9,0kW + 6,0kW
Net H/W/D
Shipment H/W/D
Net/Shipping
R744 (CO2)/1,6kg
Net H/W/D
Shipment H/W/D
Net/Shipping
* 1 Inlet water temperature 30°C, Outlet water temperature 50°C
* 2 Inlet water temperature 40°C, Outlet water temperature 60°C
* 3 Outdoor temperature 7°C Inlet water temperature 30°C, Outlet water temperature 50°C
* capacity ratings do not include any defrost operation data
105,0kg/115,0kg
1ph-230V-50Hz
3ph-230V-50Hz
1ph-230V-50Hz
20A
35,4A
52A
223L
2.5bar
10bar (9bar)
6,0kW + 6,0kW
1574mm/596mm/630mm
1736mm/700mm/767mm
155,0kg/200,0kg
7,05kW + 7,05kW
R744 (CO2)/1,7kg
49,0 dB-A
DC Rotary 2 Stage
1235mm/930mm/340mm
1330mm/1044mm/420mm
109,0kg/119,0kg
Specifications subject to change without notice.
R744
145
CO2 ECO Heating System
Energy efficient air to water heat pump technology
The SANYO Advantage
Performs even in temperatures as low as -25ºC
Easy to control
Unlike other heat pump systems which use a group of
environmentally harmful gases called Hydrofluorocarbons
(HFCs and HCFCs), SANYO’s solution is to use R744 as its
refrigerant, which is carbon dioxide (CO2), an entirely natural
and non-toxic gas that is sealed within the system.
An outdoor unit with HFC refrigerant normally operates in
temperatures of down to around -10ºC. Below this temperature
range they mostly rely on a built-in electric heater to take over.
Since electric heaters have a low COP of around 1, the result
is a significant drop in overall system efficiency. The CO2 ECO
Heating System heat pump with its CO2 refrigerant can operate
even in temperatures as low as -25ºC.
The CO2 ECO Heating System controls are intuitive and easy to
operate. They allow you to determine your preferred hot water
temperature and create your ideal indoor environment. The
7-day week program means you can adapt your space heating
to reflect whether you are out at work or relaxing at home.
Characteristics of Natural Refrigerant R744 (CO2)
R744
R410A
R407C
CO2 Natural Refrigerant
HFC
HFC
ODP*
0
0
0
GWP**
1
1900
1600
Low installation & running costs
* Ozone Depletion Potential
** Global Warming Potential
The CO2 ECO Heating System is simple to install and increased
efficiency means investment payback can be realised within
the following years. It is compatible with all standard radiators
and under floor heating systems so there is no need to replace
anything but your existing boiler.
Sanitary hot water to 65ºC
Around three quarters of an average household’s power
consumption is taken by water and space heating. Because the
CO2 ECO Heating System heat pump boiler is highly efficient
and takes high proportion of its energy consumption free from
the air, you can look forward to greatly reduced fuel bills.
CO2 refrigerant also allows higher working temperatures
compared to HFC heat pumps. Whereas other manufacturers
heat pumps can provide warm water to 45-50ºC they require an
electric booster heater to increase the temperature to meet hot
water needs.
Maximum working temperature
The CO2 ECO extracts free energy from the outside air
Low maintenance
The CO2 ECO Heating System Heat Pump does not require
any of the annual safety inspections and regular maintenance
required for gas and oil boilers making this an extremely
convenient and low cost option.
Uniquely flexible
CO2 ECO Heating System only uses water and electricity to
operate so it is ideal for properties that are not connected to
the mains gas supply. With a choice between 4.5 and 9.0kW
capacity models and a single or 3-phase power supply, it
is uniquely flexible to meet the needs of homes and small
commercial properties alike.
SANYO’s CO2 heat pump can achieve temperatures of 65ºC,
ideal for domestic hot water.
R744
146
147
CO2 ECO Heating System
Energy efficient air to water heat pump technology
Simple Installation
The world’s first CO2 rotary two-stage compressor
The CO2 ECO Heating Domestic System is easy to install
consisting of a single 4.5kW or 9.0kW capacity outdoor heat
pump unit and an indoor unit tank.
At the heart of the CO2 ECO Heating System is SANYO’s
innovative rotary two-stage compressor system, a world first
in compressor design. The compressor is resistant to high
working pressure differentials, has high reliability through load
dispersion, low leakage and low vibration. The compressor is
very compact and operates at a quiet sound level.
The system connects to all standard radiators and under floor
heating systems.
The units are self-contained and require only water and
electricity connections. To fit the CO2 ECO Heating System the
installer needs to be trained in the design and installation of
domestic hot water systems.
Training and advice for installers is available from all SANYO
distributors.
Because the system is sealed there is no handling of refrigerant
so no refrigerant handling certificate is required.
The SANYO CO2 Eco is easy to service with easy access to
electrical components, and good fault tracing functions in the
operating program.
High
Pressure
Motor
Shell
Low
Pressure
Internal
Intermediate
Pressure
R744
148
149
SANYO CO2 ECO Tank Unit
The complete heating management system
CO2 ECO Heating System
SANYO CO2 ECO Tank Unit
The SANYO CO2 ECO Tank Unit is specifically
designed to work with the CO2 ECO Heat Pump.
It is a highly sophisticated hot water management
system that simultaneously provides water at
different temperatures for domestic hot water,
radiator heating and under floor heating whilst
at the same time working with other hot water
sources.
SHP-TH90GEN-SW/ GDN-SW/ GHN-SW
SHP-TH45GEN-SW/ GDN-SW/ GHN-SW
Tank Unit Options
Power supply
HP unit
Tank unit
1ph-230V
SHP-C45DEN
SHP-TH45GEN-SW
3ph-400V
SHP-C45DEN
SHP-TH45GDN-SW
3ph-230V
SHP-C45DEN
SHP-TH45GHN-SW
1ph-230V
SHP-C90GEN
SHP-TH90GEN-SW
3ph-400V
3ph-230V
SHP-C90GDN
SHP-C90GEN
SHP-TH90GDN-SW
SHP-TH90GHN-SW
Specifications subject to change without notice.
• The HP provides abundant hot water up to 65ºC
• Wall mounted with easy to use temperature controls
• For
best performance the integrated motorised mixing
valve automatically adjusts to the temperature required by
the radiators / under floor heating.
• For more details about the ACC-CO2 Kit contact your SANYO
representative.
• Micro
chip operation monitors all functions, makes specific
adjustments and simplifies fault locating.
• Polyurethane
insulated tank for increased efficiency and
reduced temperature loss
• Electric
back up heaters provide hot water in case of
emergency or higher demand.
Sophisticated Controls
The SANYO CO2 Eco’s digital control panel is extremely user
friendly with an easy to understand menu system that makes
it easy to personalise settings for maximum comfort. Built-in
day by day controls allow you to vary temperatures throughout
the day e.g. reducing temperature at night or whilst you are
away working. Sophisticated room sensors continuously send
information to the control system to allow for fast adjustment
to the correct temperature.
Optional Connector & Control Kit
2 Step back button
You step back to the former
menu or exit a setting.
4
1
2
5
A connector is available so that the CO2 ECO Heat Pump
Unit can be used with other hot water systems.
• Complete control system for the CO2 ECO Heat Pump
• D
esigned to connect CO2 ECO to existing heating systems /
boilers
• Suitable for most hot water systems including those with
and without mixing valve regulation
150
6
3
1 Status diode
Green light: The product is in
normal operation.
Red flashing light: The product
needs attention. See message
in the display.
3 Reset button
This button lights up red when
the product needs attention.
Press the button for resetting
the alarm.
4 Display
Graphic display, back ground
lighted. Gives 8 rows of
information.
5 OK button
With this button you confirm a
value or a choice.
6 Step up/down buttons
With this buttons you step up/
down in menus or increase/
decrease values.
* sample image of SHP-TH90GDN-SW
Automatic temperature
adjustment
Prime flow
temperature
The controls automatically adjust the
water temperature depending on the
outside temperature. Therefore as
the external temperature drops the
heating inside the house increases
to ensure year round comfort.
Outdoor
temperature
The set value of the gradient is the
primary flow temperature at an
outdoor temperature of -15ºC
151
CO2 ECO Heating Domestic System
An Overview
CO2 ECO Heating System
Outdoor Unit
The heart of SANYO’s CO2 ECO Heating
System lies in the compact heat pump
unit. Situated on an exterior wall it is
extremely simple to install and benefits
from quiet operation. Using only a
small amount of electric power it takes
around two thirds of its energy from
the atmosphere. Even at ambient
temperatures as low as -25ºC enough
heat is absorbed by the liquid CO2
refrigerant to cause it to evaporate.
The CO2 gas is then pressurised in a
compressor causing it’s temperature to
rise. This heat then transfers to water
from the main supply and the CO2 cools
and condenses back to its liquid state
then passes through an expansion valve
and regains normal pressure ready to
pass through the system again.
1
4
2
1
5
2
5
Indoor unit
The CO2 Eco Tank Unit is a highly
sophisticated hot water management
system that simultaneously provides
water at different temperatures for
domestic hot water, radiator heating,
and under floor heating. It houses two
electrical heaters of which one is for
standard use and one for emergency
cases (outdoor temperature drops below
-25 degrees or there is an unusually high
demand for hot water. In emergency
situations, this heater can even operate
independently from the Heat Pump) 4
Control system
The room sensor continually sends information back
to the control system on the tank unit. The 7-day timer
allows you to adapt your hot water and space heating
to suit the rhythm of your life, while simple override
functions allow you to turn it on or off and make it
warmer or cooler so you can always enjoy maximum
comfort.
3
3
152
Radiators and under floor heating
Hot water
Just like any other water heating system, CO2 ECO
Heating System connects to standard radiator fittings
and under floor heating pipes to provide space heating.
You can enjoy superb comfort all year round.
The SANYO CO2 ECO Heating System provides you with
abundant hot water and, unlike heat pump systems from
other manufacturers that use HFC refrigerants, it has a high
working temperature of 65ºC. This is sufficient to achieve
the temperatures you need for showers and baths.
153
Hydronic Products
Content
Hydronic
Products
154
Water Chillers & Heat Pumps 156
Water Terminals 160
Fan Coil Units 164
Ducted Units 166
155
Water Chillers & Heat Pumps
Hydronic Products
SCP-AR...
SCP-AR...
• 2 new mini-chiller sizes launched in 2008
• High COP
• High COP (Coefficient of Performance)
• I ncorporated hydronic module that includes circulation
pump with expansion tank
• I ncorporated hydronic module that includes circulation
pump with expansion tank
• Installation of a buffer tank is not necessary
• Installation of a buffer tank is not necessary
• Anti-vibration supports included
• Anti‑vibration supports included
• 150 litre buffer tank available as an accessory
• R410A refrigerant
Air-to-water heat pumps
Model number
Performance
Capacity
Absorbed power
Absorbed current
E.E.R/COP
ESEER
Water flow
Available pump head
Main power supply
Expansion tank volume
Hydraulic connection diameter
Sound levels
Sound power level
Sound pressure level
System water content
Minimum water content
Dimensions & weights
HxWxD
Weight net
SCP-AR061EH5 SCP-AR071EH5 SCP-AR091EH5 SCP-AR091EH8 SCP-AR121EH5 SCP-AR121EH8 SCP-AR161EH8 SCP-AR181EH8
Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating
kW
5,1
6,1
5,9
7,3
7,1
9,0
7,2
9,1
8,5
10,65
9,0
12,7
11,4
15,2
15,7
19,6
kW
2,12
2,18
2,61
2,56
3,14
3,16
3,09
3,11
3,31
3,48
3,73
3,94
4,98
4,82
6,88
6,32
A
12,2
12,8
11,4
15,0
6,1
6,1
16,1
16,7
7,2
7,5
10,2
9,9
15,2
14,6
W/W
2,41
2,80
2,26
2,85
2,26
2,85
2,33
2,92
2,57
3,06
2,41
3,22
2,29
3,15
2,28
3,1
W/W
2,85
2,59
2,53
na
2,82
2,47
2,51
2,66
I/sec
0,24
0,29
0,28
0,34
0,34
0,44
0,34
0,43
0,41
0,5
0,42
0,6
0,55
0,75
0,75
0,94
kPa
60
55
64
57
59
47
59
47
82
66
80
53
84
68
78
59
V/Ph/Hz
230/1+N/50
400/3+N/50
230/1+N/50
400/3+N/50
I
2
2
2
2
2
2
2
2
inch
3/4” Male
1” Male
dB(A)
dB(A)
I
mm
kg
65
37
45
67
39
30
40
R410A
156
40
735x1190x340
82
90
Nominal conditions Heating
7/6°C
40°C
45°C
50
SCP-AR081E8
Cooling
8,0
3,56
7,2
2,28
2,50
0,39
73
45
50
1235x1190x340
128
98
Water chillers
Model number
SCP-AR051E5
SCP-AR081E5
Performance
Cooling
Cooling
Capacity
kW
5,2
8,0
Absorbed power
kW
2,02
3,63
Absorbed current
A
15,2
E.E.R/COP
W/W
2,77
2,23
ESEER
W/W
3,23
2,44
Water flow
I/sec
0,27
0,39
Available pump head
kPa
58
42
Main power supply
V/Ph/Hz
230/1+N/50
Expansion tank volume
I
2
Hydraulic connection diameter
inch
3/4” Male
Sound levels
Sound power level
dB(A)
63
Sound pressure level
dB(A)
37
System water content
Minimum water content
I
40
30
Dimensions & weights
HxWxD
mm
735 x 1190 x 340
Weight net
kg
87
ESEER: European Seasonal Energy Efficient Ratio published by Eurovent
Nominal conditions Cooling
Outdoor air temperature 35°C
Inlet water temperature 12°C
Outlet water temp 7°C
• R407C refrigerant
SCP-AR...
60
1235x1190x340 1235x1190x340
133
138
SCP-AR111E8
SCP-AR151E8
Cooling
Cooling
11,0
13,7
4,42
5,27
10,5
11,2
2,49
2,6
2,76
2,90
0,53
0,65
55
68
400/3+N/50
2
1” Male
65
37
Sound pressure level
Unit installed outdoor (free field)
Measuring distance 10m
Outdoor air temperature 35°C
60
SCP-AR171E8
Cooling
16,3
6,27
14,9
2,60
2,86
0,8
75
67
39
40
50
60
1235 x 1190 x 340
110
1235 x 1190 x 340
122
1235 x 1190 x 340
135
Operating Range
Outdoor max. air temperature
Outdoor min. air temperature
Outlet water min. temp
Outlet water max. temp
Cooling
43°C
-10°C
5°C
20°C
Heating
18°C
-15°C
30°C
55°C
All specifications subject to change without notice.
Air-to-water heat pumps
Model number
Performance
Capacity
Absorbed power
Absorbed current
E.E.R/COP
ESEER
Water flow
Available pump head
Main power supply
Hydraulic connection diameter
Sound levels
Sound power level
Sound pressure level
System water content
Minimum water content
Dimensions & weights
HxWxD
Weight net
SCP-AR...
kW
kW
A
W/W
W/W
I/sec
kPa
V/Ph/Hz
inch
SCP-AR241EH8
Cooling
Heating
20,8
24,0
8,85
9,0
18,6
19,9
2,35
2,67
2,78
0,97
1,17
215
185
R407C
SCP-AR401EH8
Cooling
Heating
33,5
38,4
14,55
14,75
29,3
28,7
2,30
2,60
2,72
1,68
2,0
165
95
dB(A)
dB(A)
79
51
78
50
80
52
82
54
I
80
90
120
130
1175x975x1050
303
1175x975x1050
305
1175x975x1050
327
1425x975x1050
363
SCP-AR251E8
Cooling
23,8
10,4
20,7
2,29
2,73
1,16
170
SCP-AR301E8
Cooling
31,0
13,4
24,7
2,31
2,62
1,48
200
SCP-AR401E8
Cooling
39,0
14,8
28,3
2,64
2,81
1,87
135
78
50
80
52
82
54
70
95
120
1175x975x1050
295
1175x975x1050
317
1425x975x1050
353
mm
kg
Water chillers
Model number
SCP-AR201E8
Performance
Cooling
Capacity
kW
20,7
Absorbed power
kW
8,3
Absorbed current
A
18,0
E.E.R/COP
W/W
2,49
ESEER
W/W
2,97
Water flow
I/sec
0,99
Available pump head
kPa
210
Main power supply
V/Ph/Hz
Hydraulic connection diameter
inch
Sound levels
Sound power level
dB(A)
79
Sound pressure level
dB(A)
51
System water content
Minimum water content
I
70
Dimensions & weights
HxWxD
mm
1175x975x1050
Weight net
kg
292
ESEER: European Seasonal Energy Efficient Ratio published by Eurovent
Nominal conditions Cooling
Outdoor air temperature 35°C
Inlet water temperature 12°C
Outlet water temp 7°C
SCP-AR271EH8
SCP-AR351EH8
Cooling
Heating
Cooling
Heating
25,8
27,3
30,3
35,5
9,77
10,4
13,55
13,55
20,0
20,9
27,3
25,0
2,66
2,63
2,24
2,62
2,49
2,45
1,25
1,30
1,45
1,65
160
145
200
140
400/3+N/50
1 1/4” Male
Nominal conditions Heating
7/6°C
40°C
45°C
400/3+N/50
1 1/4” Male
Sound pressure level
Unit installed outdoor (free field)
Measuring distance 10m
Outdoor air temperature 35°C
Operation Range
Outdoor max. air temperature
Outdoor min. air temperature
Outlet water min. temp
Outlet water max. temp
Cooling
43°C
-10°C
5°C
20°C
Heating
18°C
-10°C
30°C
50°C
All specifications subject to change without notice.
157
Water Chillers & Heat Pumps
(continued)
Hydronic Products
SCP-AR...
Controller Options
• High COP
• I ncorporated hydronic module that includes circulation
pump with expansion tank
• 300 litre buffer tank is available as an accessory
• Low noise level
• R410A refrigerant
SCP-AR...
Air-to-water heat pumps
Model number
Performance
Capacity
Absorbed power
Absorbed current
E.E.R/COP
ESEER
Water flow
Available pump head
Main power supply
Hydraulic connection diameter
Sound levels
Sound power level
Sound pressure level
System water content
Minimum water content
Dimensions & weights
HxWxD
Weight net
kW
kW
A
W/W
W/W
I/sec
kPa
V/Ph/Hz
inch
SCP-AR502EH8
Cooling
Heating
40,6
49,0
17,7
17,8
35,0
37,2
2,29
2,75
2,76
1,94
2,34
260
215
R407C
158
SCP-AR802EH8
Cooling
Heating
65,0
76,0
29,0
30,5
58,0
58,2
2,24
2,49
2,66
3,06
3,58
200
120
78
50
76
48
80
52
85
57
I
130
150
200
200
1175x1955x1050
589
1175x1955x1050
593
1175x1955x1050
627
1425x1955x1050
699
SCP-AR602E8
Cooling
62,0
26,4
47,7
2,35
2,65
2,96
160
SCP-AR702E8
Cooling
67,0
28,8
54,0
2,33
2,56
3,2
180
mm
kg
Nominal conditions Heating
7/6°C
40°C
45°C
Remote control
RS485 ModBus Interface
The functions and display are exactly the same as those on
built-in controller. The controller is designed to be installed
inside sheltered rooms.
• 70250056
The link can be extended up to 100 metres using a twisted pair
shielded cable.
Buffer tank
HP and LP gauges
To be used when water content of the system is below the
minimum quantity as in the specification table.
These elements, mounted on the vertical members of the unit’s
front face, display the high and low pressure values for each
refrigeration circuit.
• 7
0600110 capacity of 150lt with 400W anti-freeze electric
heater for 201-401 models
• 7
0600120 capacity of 300lt with 800W anti-freeze electric
heater for 502-802 models
Set of two water hoses
82
54
• 70600054 length 1m Ø 3/4” for 051-091 models
87
59
• 70600055 length 1m Ø 1” for 111-181 models
160
170
200
1175x1955x1050
607
1175x1955x1050
629
1425x1955x1050
679
Operating Range
Outdoor max. air temperature
Outdoor min. air temperature
Outlet water min. temp
Outlet water max. temp
Cooling
43°C
-10°C
5°C
20°C
For connection of the electronic control to a BMS system with
ModBus standard.
• 70250055 for 051-401 models
• 70250057 for 502-802 models
• 70600118 capacity of 35lt for 051-181 models
SCP-AR802E8
Cooling
78,0
29,4
55,5
2,65
2,94
3,73
90
400/3+N/50
1”1/2 Male
Sound pressure level
Unit installed outdoor (free field)
Measuring distance 10m
Outdoor air temperature 35°C
RS485 ModBus Interface
Accessories
dB(A)
dB(A)
Water chillers
Model number
SCP-AR502E8
Performance
Cooling
Capacity
kW
47,6
Absorbed power
kW
20,6
Absorbed current
A
38,7
E.E.R/COP
W/W
2,31
ESEER
W/W
2,74
Water flow
I/sec
2,28
Available pump head
kPa
220
Main power supply
V/Ph/Hz
Hydraulic connection diameter
inch
Sound levels
Sound power level
dB(A)
78
Sound pressure level
dB(A)
50
System water content
Minimum water content
I
120
Dimensions & weights
HxWxD
mm
1175x1955x1050
Weight net
kg
573
ESEER: European Seasonal Energy Efficient Ratio published by Eurovent
Nominal conditions Cooling
Outdoor air temperature 35°C
Inlet water temperature 12°C
Outlet water temp 7°C
SCP-AR602EH8
SCP-AR702EH8
Cooling
Heating
Cooling
Heating
52,6
54,0
60,6
69,3
21,2
19,0
27,1
27,0
41,1
39,2
53,5
48,8
2,48
2,84
2,24
2,57
2,34
2,45
2,51
2,58
2,90
3,31
200
180
210
150
400/3+N/50
1”1/2 Male
Remote control EKW200
• 70600027 length 1m Ø 1” 1/4 for 201-401 models
Heating
18°C
-10°C
30°C
50°C
All specifications subject to change without notice.
• 70600034 length 1.5m Ø 1” 1/2 for 502-802 models
Start-up kit
This kit is used to lower the start-up current of the single-phase
compressors.
• 7
0550004 for 051E5, 061EH5, 071EH5, 091EH5, 121EH5
models
• 70970006 x1pc for 201-351 models
• 70970007 x1pc for 401 model
• 70970006 x2pcs for 502-702 models
• 70970007 x2pcs for 802 model
Set of anti-vibration pads
To be located under girders.
• Included, 2pcs thickness 12.5mm, for 051-181 models
• 70600035, 4pcs thickness 25mm, for 201-802 models
Condensate tank heating cord
Length 1.5m, to be placed in the bottom of the condensate
tank, close to the fin tube exchanger.
• 70200055 for 061-181EH heat pump models
159
Water Terminals
Hydronic Products
FW-...
• W
ide model range for 2-pipe and 4-pipe design
system (X type size 031 and 051)
• S uitable for any commercial buildings and even for
hotels and residential applications
• X, K and FT also available with infrared remote
controller
• Quiet operation ensures maximum comfort
• 3-way valve kit features precise temperature control
in the room
• Cleanable air filter included as standard
Table Of Performances
UNIT SIZE (with wired Product code remote controller)
Product code
UNIT SIZE (with infrared remote controller)
Product code
Fan speed
max
Total cooling capacity
kW med
min
max
Sensible cooling capacity
kW med
min
max
Heating capacity
kW med
min
max
Air flow
m3/h med
min
max
Absorbed power
W med
min
max
Water flow
l/h med
min
max
Water pressure drop
kPa med
at cooling mode
min
max
Water pressure drop
kPa med
at heating mode
min
max
Sound power level (Lw)
dBA med
min
max
Sound pressure level (Lp)
dBA med
min
Water connections
inch
Coil water content
Lt
kg
Weight
mm width
height
Dimensions
depth
FW-K
Wall Mounted Unit
PNR-X031EHA for models X031, X051
PNR-X051EHA for model X061
PNR-X101EHA for models X081, X101
PNR-X032EHA for models X032, X052
PNR-X062EHA for model X062
PNR-X102EHA for models X082, X102
FW-X
Ceiling Cassette
FW-X
Ceiling Cassette 60x60
FW-X Type Ceiling Cassette - 2 pipe
FW-K011EH5FP
34360274
FW-K012EH5FP
34360278
1,24
0,80
0,94
0,58
1,72
1,11
220
150
24
19
215
135
16,1
5,8
15,3
6,1
44
37
35
28
0,3
8,0
805
270
177
FW-K021EH5FP
34360275
FW-K022EH5FP
34360279
230V-1 -50Hz
1,67
0,96
1,30
0,74
2,38
1,49
270
180
24
19
290
165
27,2
9,7
26,2
9,5
45
35
36
26
1/2” female
0,39
8,0
805
270
177
FW-K031EH5FP
34360276
FW-K032EH5FP
34360280
FW-K041EH5FP
34360277
FW-K042EH5FP
34360281
3,17
2,53
1,91
2,56
1,89
1,53
4,50
3,50
2,70
510
400
320
73
66
58
545
435
330
29,4
19,1
10,3
27,5
17,4
10,1
58
52
46
49
43
37
3,67
3,14
2,62
3,01
2,50
2,12
5,50
4,50
3,70
710
580
470
80
68
61
630
540
450
35,1
26,0
18,2
31,8
23,2
15,9
62
56
50
53
47
41
0,8
12
995
285
206
0,8
12
995
285
206
Main power supply
Total cooling capacity
Sensible cooling capacity
Heating capacity
Air flow
Absorbed power
Water flow
Sound power level (Lw)
Sound pressure level (Lp)
Water connections
Dimensions & Weights
Dimensions (H/W/D)
Max/med/min*
Max/med/min*
Max/med/min*
Max/med/min*
Max/med/min*
Max/med/min*
Max/med/min*
Max/med/min*
body
grille panel Weight (with grille panel)
FW-X031EH5
FW-X032EH5
FW-X041EH5
FW-X042EH5
FW-X051EH5
FW-X052EH5
V/Ph/Hz
kW
kW
kW
m³/h
W
l/h
dB(A)
dB(A)
inch
2,60/2,35/2,15
2,31/2,09/1,91
3,49/3,11/2,83
520/400/600
60/50/40
430/395/360
46/44/41
37/35/32
4,1/3,6/1,7
3,21/2,81/1,33
4,85/4,35/2,1
630/530/250
na
na
51/48/39
42/39/30
1/2"female
4,70/4,10/3,60
3,72/3,21/2,80
5,70/4,85/4,35
750/630/530
90/70/50
790/690/600
56/51/48
47/42/39
FWX061EH5
FWX062EH5
230/1+N/50
6,00/5,00/4,20
4,70/3,80/3,20
7,70/6,40/5,40
1300/1060/850
120/90/80
1030/860/720
51/44/40
42/35/31
mm
mm
kg
296x575x575
41x730x730
21
296x575x575
41x730x730
23
296x575x575
41x730x730
23
310x760x760
30x860x860
28
FW-X081EH5
FW-X082EH5
FW-X0101EH5
FW-X0102EH5
7,60/6,00/5,00
6,00/4,70/3,80
9,00/7,70/6,40
1470/1300/1060
150/120/90
1300/1030/860
55/51/44
46/42/35
3/4" female
9,92/8,09/6,23
7,60/6,22/4,62
13,00/10,60/8,16
2300/1700/1200
180/130/110
1700/1400/1070
57/49/43
48/40/34
310x760x1050
30x860x1150
32
310x760x1050
30x860x1150
36
(*) Fan speed
FW-X Type Ceiling Cassette - 4 pipe
Total cooling capacity
Sensible cooling capacity
Heating capacity
Air flow
Sound power level (Lw)
Sound pressure level (Lp)
Water connections
Dimensions & Weights
Max/med/min*
Max/med/min*
Max/med/min*
Max/med/min*
Max/med/min*
Max/med/min*
body
grille panel
Dimensions (H/W/D)
Weight (with grille panel)
(*) Fan speed
kW
kW
kW
m³/h
dB(A)
dB(A)
inch
mm
mm
kg
FW-X031EH5-4
2,08/1,88/1,72
1,85/1,67/1,53
1,51/1,34/1,22
520/400/600
46/44/42
37/36/33
FW-X051EH5-4
3,76/3,28/2,88
2,98/2,56/2,24
2,33/1,98/1,78
750/630/530
56/51/48
47/42/39
1/2"female
296x575x575
296x575x575
41x730x730
41x730x730
21
23
All specifications subject to change without notice.
Nominal conditions
Entering air temperature
Entering water temperature
Leaving water temperature
Cooling
27°C (db) 19°C (wb)
7°C
12°C
Heating
20°C
50°C (at same water flow as for cooling)
60°C (maximum water entering temperature)
Sound pressure level
At 2m distance in closed environment
100m³ volume with 0.5 sec reverberation time
All specifications subject to change without notice.
160
161
Water Terminals
(continued)
Hydronic Products
FW-...
Controls & Accessories
Electronic controller with infrared wireless remote control
FW-FT Type Floor/Ceiling Units - 2 pipe
FW-FT021EH5
FW-FT022EH5
Main power supply
Total cooling capacity
Sensible cooling capacity
Heating capacity
Air flow
Absorbed power
Water flow
Sound power level (Lw)
Sound pressure level (Lp)
Water connections
Dimensions & Weights
Dimensions (H/W/D)
Weight
(*) Fan speed
Max/med/min*
Max/med/min*
Max/med/min*
Max/med/min*
Max/med/min*
Max/med/min*
Max/med/min*
Max/med/min*
V/Ph/Hz
kW
kW
kW
m³/h
W
l/h
dB(A)
dB(A)
(inches)
2,10/1,20/0,90
1,50/1,00/0,70
3,10/2,00/1,60
430/300/210
40/30/26
360/206/160
48/43/35
40/35/27
mm
kg
FW-FT031EH5
FW-FT032EH5
230/1+N/50
3,19/2,10/0,90
2,47/1,50/0,70
4,07/3,00/1,60
520/430/210
46/37/26
550/360/160
50/45/35
42/37/27
1/2" female
FW-FT041EH5
FW-FT042EH5
3,90/3,10/1,65
3,00/2,50/1,25
5,00/4,40/2,10
675/570/327
70/53/35
670/530/285
54/51/40
46/43/32
680x900x190
23,5
Nominal conditions
Entering air temperature
Entering water temperature
Leaving water temperature
Cooling
27°C (db) 19°C (wb)
7°C
12°C
Control accessories
Model
CH 15-25
Code N°
9053049
Description Automatic changeover sensor for 2-pipe system
Use with
RCC 10
Heating
Sound pressure level
20°C
At 2m distance in closed environment
50°C (at same water flow as for cooling)
100m³ volume with 0,5 sec reverberation time
70°C (maximum water entering temperature)
All specifications subject to change without notice.
ASB
70250053
Air temperature sensor (bare)
RCC 10 & RCC 20
• Fan speed selection: manual
(High/Med/Low) or automatic
• Functions (manual selection)
- Cooling
- Dehumidification
- Heating
- Automatic
- Fan only
• Automatic flap
• Operating range: from 10°C to 32°C
room temperature
FW-FT
Floor/Ceiling Unit
Performance
• Suitable for control of 2-pipe water
terminals only
ASE
70250054
Air temperature sensor (with box)
RCC 10 & RCC 20
SEL-O
9060137
Speed selector receiver
RAB 30, RCC 10 & RCC 20
KVX1
70600088
Kit 3-way valve 1/2” male - Kvs 1,6
FW-X: models 03 & 05 2 & 4 pipe
KVX2
70600089
Kit 3-way valve 3/4” male - Kvs 2.5
FW-X: models 06, 08, 10
KVX3
70600071
Kit 3-way valve 1/2” male - Kvs 1,6
FW-FT & FW-Kv
All specifications subject to change without notice.
• 24 hours timer
• Address switches on remote control
(up to 4 different addresses)
• Night set-back/energy
saving (SLEEP)
• Minimum water temperature sensor
NOTE - The control does not allow centralised Heat-Cool
changeover, nor automatic changeover by external temperature
sensor.
Wired wall mounted controls
RAB 30 - 70250076
For 2&4-pipe systems with manual
Heat-cool changeover
RCC 10 - 70250051
For2-pipesystemswithremoteHeatCool changeover
RCC 20 - 70250052
For4-pipesystemswithHeat-Cool
automatic changeover
• Two-positions ON-OFF control
• Two-positions ON-OFF control
• Two-positions ON-OFF control
• Fan speed selector - 3 speeds
• Fan speed selector - 3 speeds
• Fan speed selector - 3 speeds
• Control output 230V AC
• Control output 230V AC
• Control output 230V AC
• 2-pipe control on fan
• 2-pipe control on fan
• 2-pipe control on valve:
- permanent ventilation
- fan and valves operated at the
same time
• 2-pipe control on valve:
- permanent ventilation
- f an and valves operated at the
same time
• 4-pipe control on two valves:
- permanent ventilation
- fan and valves operated at the
same time
• 4-pipe control on two valves:
- permanent ventilation
- fan and valves operated at the
same time
• R
oom temperature control from
thermostat or external sensor
(separately ordered)
• Operating range: 8-30°C
• Switching differential 1K
Accessories
Model
Code N°
Description
Use with
• Room temperature sensor on remote
control or unit
• Control of room
temperature:
- Fan ON-OFF
- Automatic valve
ON-OFF (if used)
• Heat-cool changeover:
- automatic changeover by temperature
sensor (to be ordered separately)
-m
anual changeover by remote contact
(not supplied)
• Operating modes:
- comfort
- economy
- frost protection
• Operating range: 8-30°C
• R
oom temperature control from
thermostat or external sensor
(separately ordered)
• A
utomatic heat-cool changeover, with
dead zone adjustable at 2K or 5K
• Operating modes:
- comfort
- economy
- frost protection
• Operating range: 8-30°C
• Switching differential: adjustable
• Operating LED lights
• Switching differential: adjustable
• Operating LED lights
162
163
Fan Coil Units
S-VM
Floor Standing Unit
• Very wide and complete range:
centrifugal or Cross Flow Fan,
2-pipe or 4-pipe design
• S tylish units can match any kind of
interior decor
Cross Flow fan S-VMT/HMT/VHT 151-251-351
Performance
Main power supply
Total cooling capacity
Sensible cooling capacity
Heating capacity (standard coil)
Heating capacity (add. 1 row coil)
Air flow
Absorbed power
Water flow cooling
Water pressure drop heating
Water flow heating
Water pressure drop heating
Sound power level (Lw)
Sound pressure level (Lp)
Dimensions & Weights
Dimensions (H/W/D)
Dimensions (H/W/D)
Dimensions (H/W/D)
Weight
Weight
Weight
Hydronic Products
S-HM
Ceiling Unit
Fan Coil Unit Controls
Unit Mounted Controls
Model
Code N°
Function
On/Off
Fan speed
Thermostat
S/W Changeover
Concealed Unit
• Cleanable air filter included
• E asy to install and very simple to
maintain
• E lectronic controllers available for
unit mounting and remote installation
ensure precise control of the room
temperature
• L arge choice of accessories, either
separately supplied or factory mounted
151
Max/med/min*
Max/med/min*
Max/med/min*
Max/med/min*
Max/med/min*
Max/med/min*
Max/med/min*
Max/med/min*
Max/med/min*
Max/med/min*
Max/med/min*
Max/med/min*
V/Ph/Hz
kW
kW
kW
kW
m³/h
W
l/h
kPa
l/h
kPa
dB(A)
dB(A)
1,40/1,20/1,04
1,17/0,92/0,78
2,08/1,66/1,46
1,65/1,35/1,20
300/240/190
40/30/27
240/210/180
4,0/3,2/2,4
145/120/105
2,5/1,9/1,5
48/40/34
39/31/25
251
230/1+N/50
2,40/2,08/1,70
2,02/1,62/1,31
3,10/2,70/2,30
2,60/2,25/1,95
450/360/290
50/45/37
240/210/180
14,7/11,8/8,5
225/195/170
8,9/6,9/5,4
47/42/36
38/33/27
S-VMT
S-HMT
S-VHT
S-VMT
S-HMT
S-VHT
mm
mm
mm
kg
kg
kg
530x775x225
225x775x530
530x567x218
18
18
17
530x990x225
225x990x530
530x782x218
26
26
25
Centrifugal fan S-VMC/HMC/VHC 151-251-351-401-501-601-701
Performance
151
Main power supply
V/Ph/Hz
Total cooling capacity
Max/med/min*
kW 1,50/1,30/1,10
Sensible cooling capacity
Max/med/min*
kW 1,25/1,00/0,83
Heating capacity (standard coil) Max/med/min*
kW 2,06/1,70/1,40
Heating capacity (add. 1 row coil) Max/med/min*
kW 1,75/1,35/1,25
Air flow
Max/med/min*
m³/h
300/240/190
Absorbed power
Max/med/min*
W
50/37/25
Water flow cooling
Max/med/min*
l/h
260/225/190
Water pressure drop heating Max/med/min*
kPa
5,7/4,3/3,2
Water flow heating
Max/med/min*
l/h
150/120/110
Water pressure drop heating Max/med/min*
kPa
3,7/2,8/2,2
Sound power level (Lw)
Max/med/min*
dB(A)
51/45/40
Sound pressure level (Lp)
Max/med/min*
dB(A)
42/36/31
Dimensions & Weights
Dimensions (H/W/D)
S-VMC
mm 530x775x225
Dimensions (H/W/D)
S-HMC
mm 225x775x530
Dimensions (H/W/D)
S-VHC
mm 530x510x218
Weight
S-VMC
kg
17
Weight
S-HMC
kg
17
Weight
S-VHC
kg
16
(*) Fan speed
164
S-VH
251
351
2,50/2,15/1,80
2,10/1,68/1,39
3,30/2,70/2,30
2,70/2,35/2,05
450/360/290
60/50/45
430/370/310
14,1/10,6/7,9
235/205/180
8,6/6,7/5,3
54/50/42
45/41/33
530x990x225
225x990x530
530x725x218
24
24
23
351
3,40/2,80/2,30
2,87/2,30/1,89
4,30/3,60/2,90
3,50/3,00/2,45
600/480/380
65/50/42
585/485/400
13,2/10,0/7,0
300/260/210
2,9/2,3/1,7
48/43/39
39/34/30
530x1205x225
225x1205x530
530x1007x218
29
29
28
501
601
701
3,50/2,90/2,47
2,95/2,35/1,95
4,45/3,70/3,00
3,60/3,10/2,65
600/480/380
87/80/60
600/500/425
12,3/9,2/7,0
310/270/230
2,8/2,3/1,7
51/42/37
42/33/28
401
230/1+N/50
4,00/3,44/2,90
3,35/2,68/2,21
5,20/4,35/3,65
3,69/3,31/2,65
750/600/480
95/80/65
690/590/500
17,9/13,5/10,0
315/285/250
3,7/2,9/2,3
54/48/45
45/39/36
4,80/4,15/3,60
4,05/3,24/2,67
6,60/5,50/4,70
5,30/4,50/3,90
1000/800/650
130/85/65
825/715/620
27,8/20,5/16,8
460/390/340
7,3/5,7/4,3
59/54/48
50/45/39
5,95/5,08/4,30
5,00/4,00/3,30
8,00/6,70/5,50
5,50/5,00/4,20
1200/950/750
180/145/120
1020/875/740
21,1/16,0/12,0
475/435/365
6,9/5,8/4,3
60/55/48
51/46/39
6,60/5,50/4,60
5,50/4,40/3,64
8,80/7,30/6,00
5,50/5,00/4,20
1200/950/750
180/145/120
1135/950/795
4,5/3,3/2,4
475/435/365
6,9/5,8/4,3
60/55/48
51/46/39
530x1205x225
225x1205x530
530x940x218
27
27
26
530x1205x225
225x1205x530
530x940x218
28
28
27
530x1420x225
225x1420x530
530x1155x218
33
33
31
530x1420x255
255x1420x530
530x1155x248
43
43
40
530x1420x255
255x1420x530
530x1155x248
48
48
45
Wall Mounted Controls
Model
Code N°
Function
On/Off
Fan speed
Thermostat
S/W Changeover
Control Accessories
Code N°
3021091
9053049
70250053
70250054
9060136
9060137
9060103
Model
TME
CH 15-25
ASB
ASE
SELV
SEL-O
AMU
MV-3V
9060130
TMV-M
9060131
TMV-T
9060132
TMV-C
9060133
TMV-AU
9060134
TMV-AU-C
9060135
yes
3-manual
—
—
yes
3-manual
fan only
yes
yes
3-manual
fan or valve/es
yes
yes
3-manual
fan or valve/es
no-remote
yes
3-auto
fan or valve/es
yes
yes
3-auto
fan or valve/es
no-remote
MO-3V
9060516
RAB30
70250076
RCC10
70250051
RCC20
70250052
yes
3-manual
—
—
yes
3-manual
fan and/or valve/es
yes
yes
3-manual
fan and/or 1 valve
auto or remote
yes
3-manual
fan and/or 2 valves
auto or remote
Description
Minimum water temperature sensor
Automatic change over sensor for 2 pipe system
Air temperature sensor (bare)
Air temperature sensor (with box)
Speed selector receiver for VMC and VMT units
Speed selector receiver for HMC, HMT, VHC, VHT units
Terminal block adaptor for remote control
Use with
TMV-T TMV-C TMV-AU TMV-AU-C
TMV-C TMV-AU-C RCC 10
RCC10 RCC20
RCC 10 RCC 20
RAB 30 RCC 10 RCC 20
RAB 30 RCC 10 RCC 20
—
Description
Feet (pair) for unit size from 151 to 501
Feet (pair) for unit size from 601 e 701
Auxiliary drain pan for vertical units
Auxiliary drain pan for horizontal units left side
Auxiliary drain pan for horizontal units right side
Condensate drain with quick coupling
Kit 3-way valve for unit size 151-251-351 - 1/2”F Kvs 1.6
Kit 3-way valve for unit size 401-501-601-701 - 1/2”F Kvs 2.5
Kit 3-way valve for 1-row coil - 1/2”F Kvs 1.6
Kit 3-way valve for unit size 151-251-351 factory mounted
Kit 3-way valve for unit size 401-501-601-701 factory mtd
Kit 3-way valve for 1-row coil factory mounted
Back panel for unit size 151
Back panel for unit size 251
Back panel for unit size 351 and 451
Back panel for unit size 501-601-701
Back panel for unit size 151
Back panel for unit size 251
Back panel for unit size 351 and 451
Back panel for unit size 501
Back panel for unit size 601 e 701
Kit front air return for unit size 151 factory mounted
Kit front air return for unit size 251 factory mounted
Kit front air return for unit size 351-451 factory mounted
Kit front air return for unit size 501 factory mounted
Kit front air return for unit size 601-701 factory mounted
Use with
VMC/VMT/VHC/VHT
VMC/VMT/VHC/VHT
VMC/VMT/VHC/VHT/HMC/HMT
HMC/HMT/VHC/VHT
HMC/HMT/VHC/VHT
HMC/HMT/VHC/VHT
all models
all models
all 4-pipes models
all models
all models
all 4-pipes models
VMC/VMT/HMC/HMT
VMC/VMT/HMC/HMT
VMC/VMT/HMC/HMT
VMC/HMC
HMC/HMT
HMC/HMT
HMC/HMT
HMC
HMC
VHC/VHT
VHC/VHT
VHC/VHT
VHC
VHC
Accessories
Control Accessories
Code N°
9060150
9060151
6060400
6060402
6060403
6060420
9060270
9060271
9060274
9060272
9060273
9060275
9070140
9070141
9070142
9070143
9060190
9060191
9060192
9060193
9060194
9060220
9060221
9060222
9060223
9060224
Model
PAP 1-5
PAP 6-7
BSV
BSO-SX
BSO-DX
SCR
VBPS 1-3
VBPS 4-7
VBAS 1-7
VBPM 1-3
VBPM 4-7
VBAM 1-7
PCVL 1
PCVL 2
PCVL 3-4
PCVL 5-6-7
PCO 1
PCO 2
PCO 3-4
PCO 5
PCO 6-7
KAF 1
KAF 2
KAF 3-4
KAF 5
KAF 6-7
Nominal conditions
Entering air temperature
Entering water temperature
Leaving water temperature
Cooling
27°C(db) 19°C (wb)
7°C
12°C
Heating additional 1-row coil
Heating standard coil
Sound pressure level
20°C
20°C
At 2m distance in closed environment
70°C
50°C (at same water flow as for ceiling) 100m³ volume with 0,5 sec reverberation time
60°C
All specifications subject to change without notice.
165
Ducted Units
Hydronic Products
S-HDC
S-HSC
Ducted units
Model Number (2 pipe)
Performances
Main power supply
Total cooling capacity
Sensible cooling capacity
Heating capacity
Air flow
External static pressure
Absorbed power
Water pressure drop
Cooling
Water pressure drop
Heating
Sound power level - outlet (Lw)
Sound power level - inlet+radiated (Lw)
Sound pressure level - outlet (Lp)
Sound pressure level - inlet+radiated (Lp)
Rows
Coil water content
Water connections
Dimensions (HxLxD)
Net weight
Model Number (4 pipe)
Performances
Main power supply
Total cooling capacity
Sensible cooling capacity
Heating capacity
Air flow
External static pressure
Absorbed power
Water pressure drop
Cooling
Water pressure drop
Heating
Sound power level - outlet (Lw)
Sound power level - inlet+radiated (Lw)
Sound pressure level - outlet (Lp)
Sound pressure level - inlet+radiated (Lp)
Rows - cooling+heating coils
Coil water content - cooling coil
Coil water content - heating coil
Water connection - cooling coil
Water connection - heating coil
Dimensions (HxLxD)
Net weight
V/F/Hz
Max/med/min kW
Max/med/minn kW
Max/med/min kW
Max/med/min m3/h
Max/med/min Pa
Max/med/minn W
Max/med/min kPa
Max/med/min kPa
Max/med/min dB(A)
Max/med/minn dB(A)
Max/med/min dB(A)
Max/med/min dB(A)
No
Lt
inch
mm
kg
V/F/Hz
Max/med/min kW
Max/med/min kW
Max/med/min kW
Max/med/minn m3/h
Max/med/min Pa
Max/med/min W
Max/med/min kPa
Max/med/min kPa
Max/med/min dB(A)
Max/med/min dB(A)
Max/med/min dB(A)
Max/med/min dB(A)
No
Lt
Lt
inch
inch
mm
kg
S-HDC 601-2
S-HDC 801-2
S-HDC 1001-2
S-HDC 1301-2
S-HDC 1601-2
5,59/5,06/4,54
4,58/4,07/3,59
8,13/7,25/6,41
1180/1005/850
60/50/35
205/160/125
6,2/5,2/4,3
5,3/4,4/3,6
62/57/53
63/59/55
53/48/44
54/50/46
4
2,6
3/4” male
310x1133x748
47
S-HDC 601-4
7,65/7,26/6,79
6,07/5,71/5,28
10,7/10,11/9,34
1515/1390/1255
60/50/35
290/260/240
12,2/11,2/9,9
10,3/9,4/8,3
66/63/61
69/66/63
57/54/52
60/57/54
4
3,7
1” male
310x1133x748
48
S-HDC 801-4
230/1+N/50
10,50/9,53/8,81
8,36/7,46/6,82
14,8/13,2/12,0
2130/1825/1615
60/50/35
460/390/340
18,3/15,4/13,3
15,5/13,0/11,3
65/63/59
68/65/62
56/54/50
59/56/53
4
4,6
1” male
360x1133x748
56
S-HDC 1001-4
12,89/11,67/10,08
10,13/9,03/7,65
17,91/15,9/13,4
2500/2140/1720
60/50/35
580/500/440
15,3/12,7/9,8
12,9/10,7/8,3
67/64/60
69/67/64
58/55/51
60/58/55
4
6,0
1 1/4” male
360x1445x903
78
S-HDC 1301-4
16,53/15,39/13,49
13,21/12,15/10,45
23,4/21,54/18,5
3365/3000/2450
60/50/35
960/820/680
13,8/12,0/9,5
11,7/10,2/8,0
72/69/63
75/72/67
63/60/54
66/63/58
4
7,1
1 1/4” male
435x1445x903
88
S-HDC 1601-4
5,42/4,89/4,39
4,41/3,91/3,45
4,75/4,40/3,97
1120/955/810
60/50/35
205/160/125
5,8/4,8/4,0
11,9/10,3/8,6
62/57/53
63/59/55
53/48/44
54/50/46
4+1
2,6
0,9
3/4” male
3/4” male
310x1133x748
50
7,41/7,02/6,56
5,84/5,49/5,08
6,21/5,92/5,57
1435/1325/1190
60/50/35
290/260/240
11,6/10,5/9,3
21,0/19,3/17,3
66/63/61
69/66/63
57/54/52
60/57/54
4+1
3,7
1,1
1” male
3/4” male
310x1133x748
51
230/1+N/50
10,18/9,22/8,52
8,05/7,19/6,56
8,10/7,54/7,02
2023/1735/1535
60/50/35
460/390/340
17,4/14,6/12,6
14,9/13,1/11,6
65/63/59
68/65/62
56/54/50
59/56/53
4+1
4,6
1,4
1” male
3/4” male
360x1133x748
60
12,48/11,28/9,72
9,75/8,69/7,36
10,36/9,46/8,25
2375/2035/1635
60/50/35
580/500/440
14,5/12,1/9,2
25,9/22,1/17,2
67/64/60
69/67/64
58/55/51
60/58/55
4+1
6,0
2,0
1 1/4” male
1” male
360x1445x903
83
16,01/14,89/13,04
12,72/11,70/10,05
13,36/12,72/11,25
3200/2850/2330
60/50/35
960/820/680
13,0/11,4/9,0
24,4/22,4/17,9
72/69/63
75/72/67
63/60/54
66/63/58
4+1
7,1
2,7
1 1/4” male
1” male
435x1445x903
94
Ducted units
Model Number (2 pipe)
Performances
Main power supply
Total cooling capacity
Sensible cooling capacity
Heating capacity
Air flow
External static pressure
Absorbed power
Water pressure drop
Cooling
Water pressure drop
Heating
Sound power level - outlet (Lw)
Sound power level - inlet+radiated (Lw)
Sound pressure level - outlet (Lp)
Sound pressure level - inlet+radiated (Lp)
Rows
Coil water content
Water connections
Dimensions (HxLxD)
Net weight
Model Number (4 pipe)
Performances
Main power supply
Total cooling capacity
Sensible cooling capacity
Heating capacity
Air flow
External static pressure
Absorbed power
Water pressure drop Cooling
Water pressure drop Heating
Sound power level - outlet (Lw)
Sound power level - inlet+radiated (Lw)
Sound pressure level - outlet (Lp)
Sound pressure level - inlet+radiated (Lp)
Rows - cooling+heating coils
Coil water content - cooling coil
Coil water content - heating coil
Water connection - cooling coil
Water connection - heating coil
Dimensions (HxLxD)
Net weight
S-HSC 151-2
V/F/Hz
Max/med/min kW
Max/med/min kW
Max/med/min kW
Max/med/min m3/h
Max/med/min Pa
Max/med/min W
Max/med/min kPa
Max/med/min kPa
Max/med/min dB(A)
Max/med/min dB(A)
Max/med/min dB(A)
Max/med/min dB(A)
No
Lt
inch
mm
kg
V/F/Hz
Max/med/min kW
Max/med/min kW
Max/med/min kW
Max/med/min m3/h
Max/med/min Pa
Max/med/minn W
Max/med/min kPa
Max/med/min kPa
Max/med/min dB(A)
Max/med/min dB(A)
Max/med/min dB(A)
Max/med/min dB(A)
No
Lt
Lt
inch
inch
mm
kg
S-HSC 201-2
S-HSC 301-2
S-HSC 351-2
S-HSC 501-2
S-HSC 601-2
230/1+N/50
3,48/3,16/2,95 5,10/4,65/4,27 5,84/5,28/4,81
2,57/2,32/2,15 3,94/3,56/3,24 4,38/3,93/3,55
4,25/3,84/3,55 6,39/5,78/5,30 7,17/6,43/5,84
540/480/440 930/820/730 930/820/730
65/50/40
65/50/40
65/50/40
110/99/92 190/160/140 190/160/140
12,0/10,2/9,0 19,8/16,8/14,4 12,0/10,2/8,4
104/9,1/7,8 17,6/15,0/13,0 10,4/9,1/7,2
51/49/47
57/55/51
57/55/51
58/55/53
63/60/57
63/60/57
42/40/38
48/46/42
48/46/42
49/46/44
54/51/48
54/51/48
4
3
4
2,3
2,0
2,9
1/2” female
218x669x530 218x669x530 248x884x530 248x884x530 248x1099x530 248x1099x530
16
17
24
26
29
32
S-HSC 151-4
S-HSC 301-4
S-HSC 501-4
1,71/1,59/1,46
1,32/1,22/1,11
2,21/2,05/1,87
315/290/260
65/50/40
63/55/50
10,0/8,8/7,4
8,6/7,4/6,2
51/49/46
59/56/52
42/40/37
50/47/43
3
1,0
1,71/1,59/1,46
1,32/1,22/1,11
2,00/1,87/1,73
315/290/260
65/50/40
63/55/50
10,0/8,8/7,4
8,0/7,0/6,0
51/49/46
59/56/52
42/40/37
50/47/43
3+1
1,0
0,4
1/2” female
1/2” female
218x669x530
17,4
1,98/1,83/1,67
1,47/1,35/1,23
2,46/2,25/2,04
315/290/260
65/50/40
63/55/50
16,0/13,8/11,6
13,7/11,7/9,8
51/49/46
59/56/52
42/40/37
50/47/43
4
1,3
3,14/2,87/2,68
2,36/2,15/2,00
3,84/3,49/3,24
540/480/440
65/50/40
110/99/92
16,2/13,8/12,0
13,7/11,4/10,0
51/49/47
58/55/53
42/40/38
49/46/44
3
1,7
3,14/2,87/2,68
2,36/2,15/2,00
3,24/2,98/2,81
540/480/440
65/50/40
110/99/92
16,2/13,8/12,0
3,9/3,3/2,8
51/49/47
58/55/53
42/40/38
49/46/44
3+1
1,7
0,5
1/2” female
1/2” female
248x884x530
25,7
230/1+N/50
5,10/4,65/4,27
3,94/3,56/3,24
5,16/4,75/4,38
930/820/730
65/50/40
190/160/140
19,8/16,8/14,4
9,0/8,0/7,0
57/55/51
63/60/57
48/46/42
54/51/48
3+1
2,0
0,6
1/2” female
1/2” female
248x1099x530
31,0
S-HSC 701-2
S-HSC 801-2
6,95/6,51/5,81
5,26/4,90/4,34
8,52/8,00/7,07
1200/1100/950
65/50/40
210/195/175
16,8/14,4/12,0
15,0/13,0/10,4
58/56/52
64/61/58
49/47/43
55/52/49
3
3,2
7,81/7,28/6,45
5,78/5,36/4,72
9,43/8,79/7,72
1200/1100/950
65/50/40
210/195/175
12,0/10,8/8,4
11,1/9,8/7,8
58/56/52
64/61/58
49/47/43
55/52/49
4
4,2
248x1550x530 248x1550x530
45
48
S-HSC 701-4
6,95/6,51/5,81
5,26/4,90/4,34
7,09/6,68/6,02
1200/1100/950
65/50/40
210/195/175
16,8/14,4/12,0
20,0/18,0/15,0
58/56/52
64/61/58
49/47/43
55/52/49
3+1
3,2
0,9
1/2” female
1/2” female
248x1550x530
47,7
Nominal conditions
Entering air temperature
Entering water temperature
Leaving water temperature
Cooling
27°C(db) 19°C (wb)
7°C
12°C
Heating additional 1-row coil
20°C
70°C
60°C
Heating standard coil
Sound pressure level
20°C
At 2m distance in closed environment
50°C (at same water flow as for ceiling) 100m³ volume with 0,5 sec reverberation time
All specifications subject to change without notice.
Nominal conditions
Entering air temperature
Entering water temperature
Leaving water temperature
Cooling
27°C(db) 19°C (wb)
7°C
12°C
Heating additional 1-row coil
20°C
70°C
60°C
Heating standard coil
Sound pressure level
20°C
At 2m distance in closed environment
50°C (at same water flow as for ceiling) 100m³ volume with 0,5 sec reverberation time
All specifications subject to change without notice.
166
167
Indicates conformation
with EC Directives
ISO 9001: 2001
Certificate Number: JQ116B
ISO 14001: 2001
Certificate Number: ECOOJ0303-33
SANYO reserves the right to make any variation in specification to the equipment described
or to withdraw or replace products without prior notification or public announcement. All
descriptions, illustrations, drawings and specifications in this publication are given in good faith,
but are intended to present only general particulars and shall not form any part of the contract.
For full installation details, please contact your SANYO distributor.
Rating Conditions
The cooling and heating capacities are based on the following conditions:
Cooling: Indoor temperature 27˚C DB / 19˚C WB, Outdoor temperature 35˚C DB / 24˚ C WB.
Heating: Indoor temperature 20˚C DB, Outdoor Temperature 7˚C DB.
www.sanyoaircon.com
© 2009.6 SANYO NPR-09/10UKV1
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF