Air Monitoring General Purpose (AVT55) • • • • Protected probe tip Rugged ceramic sensor Wide range of measurement applications Fast response time Windowless (AVT65) Model AVT55 • • • Less flow blockage Ideal for measuring in confined spaces Fast response time Omnidirectional (AVT75) AVT55 • • AVT65 AVT75 • Omnidirectional probe tip Accurate at low velocities from 10 to 100 ft/min (0.05 to 0.5 m/s) Ideal for unknown or varying flow direction Applications Air Velocity Transducers Models AVT55, AVT65, and AVT75 The AVT55, AVT65, and AVT75 Air Velocity Transducers are ideal for both temporary and permanent installations for air velocity measurements in research and development labs, manufacturing processes, and other applications. The full–scale range, signal output, and time constant are user selectable and can be easily changed to meet the needs of your application. • • • • • • • • Rugged. Reliable. Professional. Comfort and draft studies Critical environment installations (e.g., clean rooms and hospitals) Diffuser design analysis Monitoring drying processes Monitoring air flows in tunnels and subways Used as a standard in wind tunnels and calibration facilities Environmental monitoring in greenhouses and IAQ applications General engineering applications Air Monitoring Air Velocity Transducers Models AVT55, AVT65, AVT75 All models contain on-board electronics and calibration curves that provide a linear signal output. This linear signal is sent out as either a current (mA) or a voltage (V) signal, allowing output to a variety of data loggers or data acquisition systems. In addition, the current and voltage output ranges are user-selectable for your convenience. 2.35 in. (6.0 cm) Cable 16.4 ft (5.0 m) Specifications Models AVT55, AVT65, AVT75 Accuracy AVT55 AVT65 AVT75 3.16 in. (8.0 cm) ±2.0% of reading1, ±0.5% of full scale of selected range ±2.0% of reading1, ±0.5% of full scale of selected range ±3.0% of reading2, ±1.0% of full scale of selected range 4.95 in. (12.6 cm) Field Selectable Range AVT55 and AVT 65 25 ft/min to 200, 250, 300, 400, 500, 750, 1,000, 1,250, 1,500, 2,000, 2,500, 3,000, 4,000, 5,000, 7,500, 10,000 ft/min (0.125 m/s to 1.0, 1.25, 1.50, 2.0, 2.5, 3.0, 4.0, 5.0, 7.5, 10.0, 12.5, 15.0, 20.0, 25.0, 30.0, 40.0, 50.0 m/s) AVT75 10 ft/min to 100, 125, 150, 200, 250, 300, 400, 500 ft/min (0.05 m/s to 0.5, 0.75, 1.0, 1.25, 1.50, 2.0, 2.5 m/s) Repeatability AVT55 and AVT 65 AVT75 <±1.0% of reading3 N/A Response to Flow AVT55 and AVT 65 AVT75 0.2 sec4 0.2 sec5 8465/8475 .25 in. (6.4 mm) 0.180 in. (4.6 mm) 3 in. (7.5 cm), 6 in. (15.0 cm) 9 in. (22.5 cm), 12 in. (30.0 cm) 1.25 in. (3.2 cm) 8455 .25 in. (6.4 mm) 1.33 in. (3.4 cm) 3 in. (7.5 cm), 6 in. (15.0 cm) 9 in. (22.5 cm), 12 in. (30.0 cm) AVT55/AVT65 AVT75 Temperature Range Compensation 32 to 140°F (0 to 60°C) Operating (electronics) 32 to 200°F (0 to 93°C) Operating (sensor) 32 to 200°F (0 to 93°C) Storage 32 to 200°F (0 to 93°C) Range 25 to 10,000 fpm (0.127 10 to 500 fpm (0.05 to to 50.8 m/s), selectable 2.54 m/s), selectable Accuracy Resolution (minimum) 0.07% of selected full scale ±2% of reading at 64.4 to ±3% of reading at 68.0 to 82.4°F (18 to 28°C ) 82.4°F (20 to 26°C) +1% +0.5% of full scale of of full scale of selected selected range) range) Response time Input power Input Power 11-30 VDC or 18-38 VAC, 350 mA max6 0.2 seconds 11 to 30 VDC or 18 to 28 VAC, 350 mA maximum 1 Output Impedance Resistance Signal Time Constant Voltage mode: less than 1 ohm, 20 mA max source current Current mode: 500 ohms maximum load Field selectable 0 to 5V, 0 to 10V, 20 to 10V, 0 to 20 mA, 4 to 20 mA, Field selectable 0.05 to 10 seconds Probe Length 3 in., 6 in., 9 in., 12 in. (7.5 cm, 15 cm, 22.5 cm, or 30 cm) P/N 2980557 Rev A Copyright © 2007 by TSI Incorporated Printed in U.S.A. 5.0 seconds From 64.4 to 82.4°F (18 to 28°C), outside this range and within temperature compensation range add 0.4% per °F (0.2% per °C). 2 From 68 to 78.8°F (20 to 26°C), outside this range and within temperature compensation range add 0.9% per °F (0.5% per °C). Directed sensitivity of the Model AVT75 is a +5%/-20% of reading +0/-10 ft/min (+0/-0.05 m/s) over 270° solid angle regardless of flow direction. 3 Standard deviation based on one minute average from 100 to 1000 fpm (0.5 to 5.0 m/s). 4 For 63% of final value, tested at 1500 fpm (7.5 m/s). 5 For 63% of final value, tested at 500 fpm (2.5 m/s). 6 Input voltage must be maintained within specifications at the transducer. Specifications subject to change without notice.
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement