- Home
- Domestic appliances
- Sewing & ironing
- Electric laundry dryers
- Maytag
- MEDP475EW
- Installation Guide
- 20 Pages
Maytag MEDP475EW Installation Instructions Manual
Maytag MEDP475EW is an electric dryer designed to provide efficient and convenient clothes drying. With its advanced features and user-friendly controls, it offers a variety of options to cater to different drying needs. The dryer boasts a spacious capacity, allowing you to dry large loads of laundry in a single cycle. Its sensor dry technology automatically adjusts drying time and temperature based on the moisture level of the clothes, preventing over-drying and ensuring optimal results.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
ELECTRIC DRYER INSTALLATION INSTRUCTIONS
27" WIDE MODELS - U.S.A. ONLY
Para obtener acceso al manual de uso y cuidado en español, o para obtener información adicional acerca de su producto, visite: www.whirlpool.com
Tenga listo su número de modelo completo. Puede encontrar el número de modelo y de serie dentro de la cavidad superior de la puerta.
Table of Contents
DRYER SAFETY......................................................................... 2
INSTALLATION REQUIREMENTS ........................................... 3
Tools and Parts ...................................................................... 3
Location Requirements ......................................................... 4
ELECTRICAL REQUIREMENTS ............................................... 5
INSTALL LEVELING LEGS ....................................................... 6
ELECTRICAL CONNECTION ................................................... 6
VENTING .................................................................................. 12
Venting Requirements ......................................................... 12
Plan Vent System ................................................................. 13
Venting Kits .......................................................................... 14
Install Vent System .............................................................. 14
Connect Vent ........................................................................ 15
LEVEL DRYER ......................................................................... 15
COMPLETE INSTALLATION CHECKLIST ............................ 16
REVERSE DOOR SWING (OPTIONAL) .................................. 16
TROUBLESHOOTING .........................................BACK COVER
INSTALLATION NOTES
Date of purchase:
_________________________________
Date of installation:
_______________________________
Installer:
________________________________________
Model number:
___________________________________
Serial number:
___________________________________
W10755020A
W10755021A-SP
1
2
DRYER SAFETY
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
Tools needed:
Adjustable wrench that opens to 1" (25 mm) or hex-head socket wrench
Utility knife
Flat-blade screwdriver #2 Phillips screwdriver
Tape measure
Pliers
Wire stripper
(direct wire installations)
Tin snips
(new vent installations)
Level
Parts supplied:
Caulking gun and compound (for installing new exhaust vent)
1/4" nut driver
(recommended)
Vent clamps
Putty knife
Leveling legs (4)
Parts package is located in dryer drum. Check that all parts are included.
3
Parts needed:
Check local codes. Check existing electrical supply and venting, and read “Electrical Requirements” and “Venting Requirements” before purchasing parts.
Mobile home installations require metal exhaust system hardware, available for purchase from the dealer from whom you purchased your dryer. For further information, please reference the “Assistance or Service” section of the “Use and
Care Guide.”
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain:
■
■
A UL listed 30-amp power supply cord, rated 120/240 volt minimum. The cord should be type SRD or SRDT and be at least 4 ft. (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends.
A UL listed strain relief.
Location Requirements
Dryer Dimensions
27"
(686 mm)
22
3
/
4
"
(578 mm)
29
1
/
2
"
(749 mm)
43"
(1092 mm)
1
1
/
2
"
(38 mm)
13
3
/
4
"
(349 mm)
29
1
/
2
"
(749 mm)
You will need:
■
■
A location allowing for proper exhaust installation.
See “Venting Requirements.”
A separate 30 amp circuit.
■
■
■
If you are using power supply cord, a grounded electrical outlet located within 2 ft. (610 mm) of either side of dryer.
See “Electrical Requirements.”
A sturdy floor to support the total weight (dryer and load) of 200 lbs. (90.7 kg). The combined weight of a companion appliance should also be considered.
Level floor with maximum slope of 1" (25 mm) under entire dryer. (If slope is greater than 1" [25 mm], install Extended
Dryer Feet Kit, Part Number 279810.) If not level, clothes may not tumble properly and automatic sensor cycles may not operate correctly.
Do not operate your dryer at temperatures below 45°F (7°C). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.
Installation clearances:
The location must be large enough to allow the dryer door to open fully.
A B
A. Wide opening side-swing door
B. Wide opening hamper door
*Most installations require a minimum 5½" (140 mm) clearance
behind the dryer for the exhaust vent with elbow. See “Venting
Requirements.”
Minimum spacing for recessed area or closet installation
The dimensions shown following are for the minimum spacing allowed.
■
Additional spacing should be considered for ease of installation and servicing.
■
■
■
Additional clearances might be required for wall, door, and floor moldings.
Additional spacing of 1" (25 mm) on all sides of the dryer is recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are acceptable.
■
Companion appliance spacing should also be considered.
Minimum Required Spacing
18"*
(457 mm)
14" max.*
(356 mm)
48 in.
2
*
(310 cm )
2
1"
(25 mm)
27"
(686 mm)
A
1"
(25 mm)
1"*
(25 mm)
29
½"
(749 mm)
5
½"*
(140 mm)
B
24 in.
2
*
(155 cm )
2
C
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
*Additional spacing recommended
3"*
(76 mm)
3"*
(76 mm)
4
Mobile home - Additional installation requirements
This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280).
■
Metal exhaust system hardware, which is available for purchase from your dealer.
■
Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.
ELECTRICAL REQUIREMENTS
It is your responsibility:
■
■
■
■
■
To contact a qualified electrical installer.
To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSI/NFPA
70-latest edition and all local codes and ordinances.
The National Electrical Code requires a 4-wire power supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.
A copy of the above code standards can be obtained from:
National Fire Protection Association, One Batterymarch Park,
Quincy, MA 02269.
To supply the required 3 or 4 wire, single phase, 120/240 volt,
60 Hz, AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.
Do not use an extension cord.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
Electrical Connection
To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.
■
■
If local codes do not permit the connection of a neutral ground wire to the neutral wire, see “Optional 3-wire connection” section.
■
■
This dryer is manufactured ready to install with a 3-wire electrical supply connection. The neutral ground wire is permanently connected to the neutral conductor (white wire) within the dryer. If the dryer is installed with a 4-wire electrical supply connection, the neutral ground wire must be removed from the external ground connector screw (green screw), and secured under the neutral terminal (center or white wire) of the terminal block. When the neutral ground wire is secured under the neutral terminal (center or white wire) of the terminal block, the dryer cabinet is isolated from the neutral conductor.
A 4-wire power supply connection must be used when the dryer is installed in a location where grounding through the neutral conductor is prohibited. Grounding through the neutral is prohibited for (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductors.
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain:
A UL listed 30-amp power supply cord, rated 120/240 volt minimum. The cord should be type SRD or SRDT and be at least 4 ft. (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends.
■
A UL listed strain relief.
If your outlet looks like this:
4-wire receptacle
(14-30R)
Then choose a 4-wire power supply cord with ring or spade terminals and UL listed strain relief. The 4-wire power supply cord, at least 4 ft. (1.22 m) long, must have
4 10-gauge solid copper wires and match a 4-wire receptacle of NEMA Type 14-30 R.
The ground wire (ground conductor) may be either green or bare. The neutral conductor must be identified by a white cover.
If your outlet looks like this:
Then choose a 3-wire power supply cord with ring or spade terminals and UL listed strain relief. The 3-wire power supply cord, at least
4 ft. (1.22 m) long, must have 3 10-gauge solid copper wires and match a 3-wire receptacle of
NEMA Type 10-30R.
3-wire receptacle
(10-30R)
Choose a standard power supply cord connector:
Flanged spade connectors
Ring connectors
If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire) and be:
■
■
■
Flexible armored cable or nonmetallic sheathed copper cable
(with ground wire), covered with flexible metallic conduit. All current-carrying wires must be insulated.
10-gauge solid copper wire (do not use aluminum).
At least 5 ft. (1.52 m) long.
5
INSTALL LEVELING LEGS ELECTRICAL CONNECTION
Power Supply Cord
1.
Prepare dryer for leveling legs
6
To avoid damaging floor, use a large flat piece of cardboard from dryer carton; place under entire back edge of dryer.
Firmly grasp dryer body (not console panel) and gently lay dryer down on cardboard.
2.
Screw in leveling legs
Using a wrench and tape measure, screw legs into leg holes until bottom of foot is approximately 1½" (38 mm) from bottom of dryer.
Now stand the dryer on its legs. Slide the dryer until it is close to its final location. Leave enough room for electrical connection and to connect the exhaust vent.
NOTE: Refer to Dryer Dimensions in the Location
Requirements.
Electrical Connection Options
1.
Choose electrical connection type
Power supply cord 4-wire receptacle
(NEMA Type 14-30R): Go to 4-wire
Power Supply Cord Connection section.
Then, go to Venting Requirements.
Power supply cord 3-wire receptacle
(NEMA Type 10-30R): Go to 3-wire
Power Supply Cord Connection section.
Then go to Venting Requirements.
4-wire direct connection: Go to 4-wire
Direct Wire Connection section. Then go to Venting Requirements.
3-wire direct connection: Go to 3-wire
Direct Wire Connection section. Then go to Venting Requirements.
NOTE:
If local codes do not permit connection of a cabinet-ground conductor to neutral wire, go to “Optional
3-wire Connection” section. This connection may be used with either a power supply cord or a direct wire connection.
Direct Wire
Power Supply Cord Connection
Power supply cord strain relief
1.
Attach power supply cord
strain relief
C
D
A
B
Remove the screws from a 3/4" (19 mm) UL listed strain relief
(UL marking on strain relief). Put the tabs of the two clamp sections (C) into the hole below the terminal block opening
(B) so that one tab is pointing up (A) and the other is pointing down (D), and hold in place. Tighten strain relief screws just enough to hold the two clamp sections (C) together.
2.
Attach power supply cord to strain relief
B
2.
Remove terminal block cover
C A
D
E
F
Before you start, disconnect power. Remove hold-down screw (D) and terminal block cover (A).
A. Terminal block cover
B. External ground conductor screw
C. Center terminal block screw
D. Hold-down screw
E. Neutral ground wire
F. Hole below terminal block cover
Put power supply cord through the strain relief. Be sure that the wire insulation on the power supply cord is inside the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Do not further tighten strain relief screws at this point.
If your outlet looks like this:
Power supply cord 4-wire receptacle
(NEMA Type 14-30R):
Go to 4-Wire Power Supply Cord
Connection on page 8.
Power supply cord 3-wire receptacle
(NEMA Type 10-30R):
Go to 3-Wire Power Supply Cord
Connection on page 8.
7
4-wire Power Supply Cord Connection
IMPORTANT:
A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wire connections.
3.
Connect ground wire
4-wire receptacle (NEMA type 14-30R)
4-prong plug
A
F
Connect ground wire (F) (green or bare) of power supply cord to external ground conductor screw (A). Tighten screw.
4.
Connect remaining wires
Spade terminals with upturned ends
Ring terminals
1.
Prepare to connect neutral ground wire and neutral wire.
E
B
A
Remove center terminal block screw (B). Remove neutral ground wire (E) from external ground conductor screw (A).
2.
Connect neutral ground wire and neutral wire
Connect remaining wires to outer terminal block screws.
Tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.
Now, go to Venting Requirements.
3-wire Power Supply Cord Connection
IMPORTANT
: Use where local codes permit connecting cabinet-ground conductor to neutral wire.
B
E
C
Connect neutral ground wire (E) and neutral wire (white or center) (C) of power supply cord under center terminal block screw (B). Tighten screw.
3-wire receptacle (NEMA type 10-30R)
Spade terminals with upturned ends
3-prong plug
Ring terminals
8
1.
Remove center screw
B
Direct Wire Connection
Direct wire strain relief
1.
Attach direct wire strain relief
A
B
C
Remove center terminal block screw (B).
2.
Connect neutral wire
B
C
Connect neutral wire (white or center) (C) of power supply cord to center terminal block screw (B). Tighten screw.
3.
Connect remaining wires
Unscrew the removable conduit connector (A) and any screws from a 3/4" (19 mm) UL listed strain relief (UL marking on strain relief). Put the threaded section of the strain relief
(C) through the hole below the terminal block opening (B).
Reaching inside the terminal block opening, screw the removable conduit connector (A) onto the strain relief threads.
2.
Attach direct wire cable to strain relief
Connect remaining wires to outer terminal block screws.
Tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to Venting Requirements.
Put direct wire cable through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Tighten strain relief screw against the direct wire cable.
If your wiring looks like this:
4-wire direct connection:
Go to 4-Wire Direct Connection on page 10.
3-wire direct connection:
Go to 3-Wire Direct Connection on page 10.
9
4-wire Direct Wire Connection
IMPORTANT:
A 4-wire connection is required for mobile homes and where local codes do not permit 3-wire connections.
1.
Prepare your 4-wire cable for
direct connection
1"
(25 mm)
4.
Connect ground wire
5"
(127 mm
)
Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer may be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable, leaving bare ground wire at 5" (127 mm). Cut 1
1
/
2
" (38 mm) from remaining 3 wires. Strip insulation back 1" (25 mm). Shape ends of wires into hooks.
2.
Prepare to connect neutral
ground wire and neutral wire
A
F
Connect ground wire (green or bare) (F) of direct wire cable to external ground conductor screw (A). Tighten screw.
5.
Connect remaining wires
E
B
A
Remove center terminal block screw (B). Remove neutral ground wire (E) from external ground conductor screw (A).
3.
Connect neutral ground wire
and neutral wire
B
C
E
Place hooked ends of remaining direct wire cable wires under outer terminal block screws (hooks facing right).
Squeeze hooked ends together and tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to
Venting Requirements.
3-wire Direct Wire Connection
IMPORTANT: Use where local codes permit connecting cabinet-ground conductor to neutral wire.
1.
Prepare your 3-wire cable for
direct connection
1"
(25 mm)
3½"
(89 mm)
Connect neutral ground wire (E) and place hooked end (hook facing right) of neutral wire (white or center wire) (C) of direct wire cable under center screw of terminal block (B). Squeeze hooked ends together and tighten screw.
10
Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer may be moved if needed.
Strip 3
1
/
2
" (89 mm) of outer covering from end of cable. Strip insulation back 1" (25 mm). If using 3-wire cable with ground wire, cut bare wire even with outer covering. Shape wire ends into hooks.
2.
Remove center screw
B
Optional 3-wire Connection
IMPORTANT:
You must verify with a qualified electrician that this grounding method is acceptable before connecting.
1.
Prepare to connect neutral
ground wire and neutral wire
E
B
Remove center terminal block screw (B).
3.
Connect neutral wire
C
B
Place hooked end of neutral wire (white or center) (C) of direct wire cable under center terminal block screw (B). Squeeze hooked end together. Tighten screw.
4.
Connect remaining wires
Remove center terminal block screw (B). Remove neutral ground wire (E) from external ground conductor screw (A).
2.
Connect neutral ground wire
and neutral wire
B
E
C
Connect neutral ground wire (E) and neutral wire (white or center wire) (C) of power supply cord or cable under center terminal block screw (B). Tighten screw.
3.
Connect remaining wires
Place hooked ends of remaining direct wire cable wires under outer terminal block screws (hooks facing right).
Squeeze hooked ends together and tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to Venting
Requirements.
Place hooked ends of remaining wires under outer terminal block screws (hooks facing right). Tighten screws.
11
4.
Connect external ground wire
A
G
Connect a separate copper ground wire (G) from the external ground conductor screw (A) to an adequate ground. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to Venting Requirements.
Rigid metal vent:
■
Recommended for best drying performance and to avoid crushing and kinking.
Flexible metal vent:
(Acceptable only if accessible to clean)
■
■
Must be fully extended and supported in final dryer location.
Remove excess to avoid sagging and kinking that may result in reduced airflow and poor performance.
■
Do not install in enclosed walls, ceilings, or floors.
■
The total length should not exceed 7
3
/
4
ft. (2.4 m).
NOTE:
If using an existing vent system, clean lint from entire length of the system and make sure exhaust hood is not plugged with lint. Replace plastic or metal foil vents with rigid metal or flexible metal vents. Review Vent System Chart and if necessary, modify existing vent system to achieve best drying performance.
Exhaust hoods:
■
Must be at least 12" (305 mm) from ground or any object that may obstruct exhaust (such as flowers, rocks, bushes, or snow).
Recommended Styles:
VENTING
Venting Requirements
Louvered hood
Acceptable Style:
Box hood
WARNING:
To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT:
Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building. Only rigid or flexible metal vent shall be used for exhausting.
Angled hood
Elbows:
■
45° elbows provide better airflow than 90° elbows.
Good
Better
4"
(102 mm)
■
■
4" (102 mm) heavy metal exhaust vent
Only a 4" (102 mm) heavy metal exhaust vent and clamps may be used.
Do not use plastic or metal foil vent.
12
Clamps:
■
Use clamps to seal all joints.
■
Exhaust vent must not be connected or secured with screws or other fastening devices that extend into interior of duct and catch lint. Do not use duct tape.
Optional exhaust installations:
Exhaust can be converted out the right side, left side, or through the bottom (4-way vent kit). Each kit includes step-by-step instructions. For ordering information, see “Venting Kits”.
See “Venting Kits” for more information.
Plan Vent System
Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer.
Other installations are possible.
B
A
A. Dryer
B. Elbow
C. Wall
D. Exhaust hood
E. Clamps
C
D
E
F
G
B
I
H
F. Rigid metal or flexible metal vent
G. Vent length necessary to connect elbows
H. Exhaust outlet
I. Optional side exhaust outlet
A B
A. Standard rear offset exhaust installation
B. Left or right side exhaust installation
C. Bottom exhaust installation
C
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown.
Refer to the manufacturer’s instructions.
Over-The-Top installation (also available with one offset elbow)
Periscope installation
NOTE: The following kits for close clearance alternate installations are available for purchase.
13
Venting Kits
For more information, call 1-800-901-2042, or visit us at
www.applianceaccessories.com. In Canada, call
1-800-807-6777 or visit us at www.whirlpoolparts.ca.
Part Number Descriptions
8171587RP 0–5" Metal vent periscope
4396037RP 0"-18" Metal vent periscope
4396011RP 18" - 29" Metal vent periscope
4396014
4392892
279818
29" - 50" Metal vent periscope
In-Wall metal DuraVent™ Periscope
4-way vent kit - white
W10186596 4-way vent kit - universal grey
4396028 Sure Connect™ venting kit
(over-the-top installation)
4396009RP 5' Universal connect vent, flexible dryer venting
4396010RP 6' SecureConnect™ vent, flexible dryer venting
4396013RB Dryer vent installer’s kit
4396033RP 5' flexible dryer venting with clamps
4396727RP 8' flexible dryer venting with clamps
4396004 Dryer offset elbow
4396005 Wall offset elbow
4396006RW DuraSafe™ close elbow
4396007RW Through-the-wall vent cap
4396008RP 4" steel dryer venting clamps - 2 pack
8212662 Flush mounting louvered vent hood 4"
Special provisions for mobile home installations:
The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.
Determine vent length and elbows needed for best drying performance:
■
Use following Vent System Chart to determine type of vent material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified in Vent system chart. Exhaust systems longer than those specified will:
■
■
Shorten life of dryer.
Reduce performance, resulting in longer drying times and increased energy usage.
The Vent System Chart provides venting requirements that will help achieve best drying performance.
Number of
90° turns or elbows
0
Vent System Chart
Type of vent
Rigid metal
Box/louvered hoods
64 ft. (20 m)
Angled hoods
58 ft. (17.7 m)
1
2
3
4
Rigid metal
54 ft. (16.5 m)
Rigid metal
44 ft. (13.4 m)
Rigid metal
35 ft. (10.7 m)
Rigid metal
27 ft. (8.2 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
NOTE: Side and bottom exhaust installations have a 90º turn inside the dryer. To determine maximum exhaust length, add one 90º turn to the chart.
Install Vent System
1.
Install exhaust hood
12" min.
(305 mm)
Determine vent path:
■
■
■
■
■
Select route that will provide straightest and most direct path outdoors.
Plan installation to use fewest number of elbows and turns.
When using elbows or making turns, allow as much room as possible.
Bend vent gradually to avoid kinking.
Use as few 90° turns as possible.
12" min.
(305 mm)
Install exhaust hood and use caulking compound to seal exterior wall opening around exhaust hood.
14
2.
Connect vent to exhaust hood
LEVEL DRYER
1.
Level Dryer
Vent must fit over the exhaust hood. Secure vent to exhaust hood with 4" (102 mm) clamp. Run vent to dryer location using straightest path possible. Avoid 90° turns. Use clamps to seal all joints. Do not use duct tape, screws, or other fastening devices that extend into interior of vent to secure vent, because they can catch lint.
Connect Vent
1.
Connect vent to exhaust outlet
Check levelness of dryer from side to side. Repeat from front to back.
NOTE: The dryer must be level for the moisture sensing system to operate correctly.
Using a 4" (102 mm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure vent is clean. Dryer vent must fit over dryer exhaust outlet and inside exhaust hood. Check that vent is secured to exhaust hood with a 4" (102 mm) clamp.
2.
Move dryer to final location
Not Level LEVEL Not Level
2.
Tighten and adjust leveling legs
If dryer is not level, prop up using a wood block, use wrench to adjust legs up or down, and check again for levelness.
Once dryer is level, make sure all four legs are snug against the ground before tightening them.
Move dryer to final location. Avoid crushing or kinking vent.
After dryer is in place, remove corner posts and cardboard from under the dryer.
15
COMPLETE INSTALLATION
CHECKLIST
q
Check that all parts are now installed. If there is an extra part, go back through steps to see what was skipped.
q
Check that you have all of your tools.
q
Dispose of/recycle all packaging materials.
q
Check dryer’s final location. Be sure vent is not crushed or kinked.
q
Check that dryer is level. See “Level Dryer”.
q
Remove film on console and any tape remaining on dryer.
q
Wipe dryer drum interior thoroughly with a damp cloth to remove any dust.
q
Read “Dryer Use” in your “Use and Care Guide.” q
Set the dryer on a full heat cycle (not an air cycle) for
20 minutes and start the dryer.
If the dryer will not start, check the following:
■
■
Controls are set in a running or “On” position.
Start button has been pushed firmly.
■
■
Dryer is plugged into an outlet and/or electrical supply is on.
Household fuse is intact and tight, or circuit breaker has not tripped.
■
Dryer door is closed.
q
When the dryer has been running for 5 minutes, open the dryer door and feel for heat. If you feel heat, cancel cycle and close the door.
If you do not feel heat, turn off dryer, and check the following:
■
There may be 2 household fuses or circuit breakers for the dryer. Check that both fuses are intact and tight, or that both circuit breakers have not tripped. If there is still no heat, contact a qualified technician.
NOTE: You may notice an odor when the dryer is first heated.
This odor is common when the heating element is first used.
The odor will go away.
REVERSE DOOR SWING
(OPTIONAL)
If your door is the 27" Wide Side-Swing Door, go to steps 1–11 beginning on this page.
27" Wide Model Side-Swing Door
1.
Place towel on top of dryer to avoid damaging the surface.
2.
Remove bottom screws
Open dryer door. Remove bottom screws from dryer cabinet side of hinges. Loosen (do not remove) top screws from dryer cabinet side of hinges.
3.
Place towel on dryer
Lift door off top screws
If your door is the 27" Wide Side-Swing Door with Glass, go to steps 1–13 beginning on page 18.
Lift door until top screws in dryer cabinet are in large part of hinge slot. Pull door forward off screws. Set door (handle side up) on top of dryer. Remove top screws from dryer cabinet.
NOTE: Magnetized screwdriver is helpful.
16
4.
Remove screws from hinges
7.
Flip door over
Remove screws attaching hinges to door.
5.
Remove screws from door
Flip door over so handle side is down.
8.
Attach door hinges
Remove screws at top, bottom, and side of door (6 screws).
Keep door screws separate from hinge screws as they are different sizes. Holding door over towel on dryer, grasp sides of outer door and lift to separate it from inner door.
NOTE: Do not pry apart with putty knife or screwdriver.
Do not pull on door seal or plastic door catches.
6.
Rotate outer door
Rotate outer door 180º and set it back down on inner door.
Be certain to keep cardboard spacer centered between doors. Reattach outer door panel to inner door panel so handle is on the side where hinges were just removed. Insert
6 door screws.
Reattach door hinges to dryer door so that the larger hole is at the bottom of the hinge.
9.
Remove and transfer plugs
Remove the 4 screws that attach 2 plugs on the left side.
Transfer plugs to opposite side using the same 4 screws.
17
10.
Insert screws in hinge holes on dryer cabinet
2.
Remove bottom screws
NOTE: 2 people may be needed to reinstall door.
Insert screws into the bottom holes on left side of dryer cabinet.
Tighten screws halfway. Position door so large end of door hinge slot is over screws. Slide door up so screws are in bottom of slots. Tighten screws. Insert and tighten top screws in hinges.
11.
Check door strike alignment
Open dryer door. Remove bottom screws from dryer cabinet side of hinges. Loosen (do not remove) top screws from dryer cabinet side of hinges.
3.
Lift door off top screws
Close door and check that door strike aligns with door catch.
If it is needed, slide door catch left or right within slot to adjust alignment.
27" Wide Model Side-Swing Door with Glass
1.
Place towel on dryer
Lift door until top screws in dryer cabinet are in large part of hinge slot. Pull door forward off screws. Set door (handle side up) on top of dryer. Remove top screws from dryer cabinet.
4.
Remove screws from hinges
Remove screws attaching hinges to door.
Place towel on top of dryer to avoid damaging the surface.
18
5.
Flip door over
8.
Rotate outer door
Flip door over so handle side is down.
6.
Remove screws from door
Rotate outer door 180º and set it back down on inner door.
Be certain to keep cardboard spacer centered between doors. Reattach outer door panel to inner door panel so handle is on the side where hinges were just removed. Insert
4 door screws.
9.
Attach door hinges
Remove screws at top, bottom, and side of door (4 screws).
Keep door screws separate from hinge screws as they are different sizes.
7.
Separate inner from outer door
Holding door over towel on dryer, pry inner door and lift to separate it from outer door.
NOTE: Do not pull on door seal or plastic door catches.
Reattach door hinges to dryer door so that the larger hole is at the bottom of the hinge.
19
10.
Remove door strike and door strike label
Door strike Door strike label
12.
Insert screws in hinge holes on dryer cabinet
Remove door strike and door strike label from dryer cabinet.
Insert the door strike into hole where door strike label was removed and secure with screw. Cover original door strike hole with door strike label and press firmly into place.
11.
Remove and transfer plugs
NOTE: 2 people may be needed to reinstall door.
Insert screws into the bottom holes on left side of dryer cabinet. Tighten screws halfway. Position door so large end of door hinge slot is over screws. Slide door up so screws are in bottom of slots. Tighten screws. Insert and tighten top screws in hinges.
13.
Check door strike alignment
Remove the 4 screws that attach 2 plugs on the left side.
Transfer plugs to opposite side using the same 4 screws.
Close door and check that door strike aligns with door catch.
If it is needed, slide door catch left or right within slot to adjust alignment.
TROUBLESHOOTING
See the Use and Care Guide or visit our website and reference “Frequently Asked Questions” to possibly avoid the cost of a service call.
W10755020A
W10755021A-SP
®/™ ©2015 Whirlpool. All rights reserved.
®/™ ©2015 Whirlpool. Tous droits réservés.
02/15
Printed in U.S.A.
Imprimé au E.E.U.U.
advertisement
Frequently Answers and Questions
What is the correct dryer dimensions?
What type of spacing should be allowed around the dryer?
What are the dryer's voltage requirements?
Can the dryer be installed on a mobile home?
What should be used to clean the dryer lint filter?
Related manuals
advertisement
Table of contents
- 2 DRYER SAFETY
- 3 INSTALLATION REQUIREMENTS
- 3 Tools and Parts
- 4 Location Requirements
- 5 ELECTRICAL REQUIREMENTS
- 6 INSTALL LEVELING LEGS
- 6 ELECTRICAL CONNECTION
- 12 VENTING
- 12 Venting Requirements
- 13 Plan Vent System
- 14 Venting Kits
- 14 Install Vent System
- 15 Connect Vent
- 15 LEVEL DRYER
- 16 COMPLETE INSTALLATION CHECKLIST
- 16 REVERSE DOOR SWING (OPTIONAL)