Danfoss APP S 674 3.0-3.5, 5.1-9.0, 21-38 pumps Instructions
Below you will find brief information for pumps APP S 674 3.0-3.5, pumps APP S 674 5.1-9.0, pumps APP S 674 21-38. These high-pressure pumps are designed for high-pressure applications such as reverse osmosis. They are robust and reliable, with a long service life. You can mount these pumps horizontally or vertically, and they are easy to install. This document explains how to build up the pump unit, initial start-up, operation, long-term shutdown, storage, and service and warranty.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
MAKING MODERN LIVING POSSIBLE
Instruction
APP S 674 pumps
APP S 674 3.0-3.5 / APP S 674 5.1-9.0
APP S 674 21-38
ro-solutions.com
Instruction
Table of Contents
1. Identification
APP S 674 pumps
Our CLP RO pumps have changed name as listed below:
CLP674 050-058 RO will now be called APP S 674 3.0-3.5
CLP674 085-152 RO will now be called APP S 674 5.1-9.0
CLP674 365-640 RO will now be called APP S 674 21-38
This is ONLY a name change.
Pump:
Code No:
Serial No: ccm / rpm:
900 ≤rpm≤1800
0.5 bar≤Pin≤5 barg
20 bar≤Pout≤80 barg
4°C≤Tmedia≤95°C
Media:
Warning
Use only 10µm filter with a
β-value>5000. Bleed the pump befor initial startup.
EX II 2 G bc T3
2
180R9276 / 521B1245 / DKCFN.PI.013.Z1.02 / 03.2013
Instruction
2. System design
APP S 674 pumps
2.1 Open system design
A
Inlet line:
Minimize pressure loss by allowing for maximum flow, minimum pipe length, as few bends/connections as possible, and fittings with small pressure losses.
B
Inlet filter:
Install the inlet filter (1) in front of the
APP S 674 pump (4). Please consult the
Danfoss filter data sheet for guidance on how to select the right filter.
C
Monitoring pressure switch:
Install the monitoring pressure switch (3) between the filter and the pump inlet. Set the minimum inlet pressure according to pump specifications. The monitoring pressure switch stops the pump if inlet pressure is lower than the set minimum pressure.
D Monitoring temperature switch when the
pump operates in a hazardous area:
Install the monitoring temperature switch between the filter and the pump, on either side of the monitoring pressure switch. Set the temperature according to pump specifications. The monitoring temperature
E
F
switch stops the pump if inlet temperature is higher than the set value.
Connections:
Ensure flange loads (5) do not exceed max. allowable loads on process connections according to API 674 3 rd
edition (pipe size).
Inlet pressure:
In order to eliminate the risk of cavitation and other pump damage, inlet pressure must be maintained in-betweens pump specifications.
G
LP relief valve (2):
Can be installed in order to avoid system or pump damage in case the pump stops momentarily or spinning backwards.
H
HP relief valve:
As the Danfoss APP S 674 pump begins to create pressure and flow immediately after start-up and regardless of any counter pressure, a pressure relief valve (6) should be installed to prevent system damage.
Note: If a non-return valve is mounted in the inlet line, a low-pressure relief valve is also required between the non-return valve and the pump to protect against high-pressure peaks.
4 5
6
1
PI
2 3
PS
5
2.2 RO system with APP S 674 pump
The numbers in brackets refer to the drawing on next page.
A Dimension the inlet line to obtain minimum pressure loss (large flow, minimum pipe length, minimum number of bends/ connections, and fittings with small pressure losses).
B Place an inlet filter (1) in front of the
APP S 674 pump (2). Please consult section
10, “Filtration” for guidance on how to select the right filter. Thoroughly clean pipes and flush system prior to start-up.
C Place a monitoring pressure switch (3) set at min. inlet pressure between filter and pump inlet.
The monitoring switch must stop the pump at pressures lower than minimum pressure.
D Ensure flange loads (4) do not exceed max. allowable loads on process connections according to API 674 3 rd
edition (pipe size).
E In order to eliminate the risk of damage and cavitation, a positive pressure at the inlet
(5) is always to be maintained at min. inlet pressure and max. inlet pressure. Recommend to install safety valve or a pressure relief valve (9) in order to avoid high pressure peaks in case the pump stops
momentarilly or is spinning backwards.
F For easy system bleeding and flushing, a bypass non-return valve (6) is integrated in the APP S 674 pump.
G A non-return valve (7) in outlet can be installed in order to avoid backspin of the pump. The volume of water in the membrane vessel works as an accumulator and will send flow backwards in case the pump stops momentarily.
H A safety valve or a pressure relief valve (8) can be installed in order to avoid system damage as the Danfoss APP S 674 pump creates pressure and flow immediately after start-up, regardless of any counter pressure.
Note: If a non return valve is mounted in the inlet line, a low pressure relief valve is also required between non return valve and pump as protection against high pressure peaks.
180R9276 / 521B1245 / DKCFN.PI.013.Z1.02 / 03.2013
3
Instruction
APP S 674 pumps
2.3 Protection of too high pressures
The pump should be protected against too high pressure by using a safety valve or a pressure relief valve.
The valve should be placed as close to the pump as possible.
The opening characteristics of the valve must not result in peak pressures higher than 80 bar
(1,160 psi).
The valve outlet must not be connected directly to the pump suction line. It must be connected directly to the drain.
3. Building up the pump unit
3.1 Mounting
4
D
A: Flexible coupling
B: Bell housing
C: Motor shaft
D: Pump flange
1. Mount the coupling on the pump shaft.
Ensure an air gap between coupling and pump flange of min. 4 mm (0.16 in).
2. Mount the bell housing on the pump. Secure nuts with the right torque.
3. Measure the longest distance “A” from top of bell housing to the button of coupling claw.
4. Mount the coupling on the motor shaft.
Ensure the coupling and motor flange are not in contact with each other.
180R9276 / 521B1245 / DKCFN.PI.013.Z1.02 / 03.2013
Instruction APP S 674 pumps
5. Measure from motor flange to the top of the coupling. The measurement “B” shall be
3-5 mm (0.12 - 0.2 in) shorter than the measurement “A”.
6. Adjust respectively, verify the measurement, and secure both couplings with the right torques on the locking screws (see coupling operation & mounting instruction).
7. Mount the flexible gear ring and mount the bell housing/pump on the motor. After mounting it must be possible to move the flexible gear ring 3-5 mm (0.12 - 0.2 in) axial
“C”. The check can be done through the inspection hole of the bell housing. Secure flange bolts with the right torque.
If alternative mounting is desired, please contact
Danfoss High Pressure Pumps.
Choose proper tolerances to ensure an easy mounting of the flexible coupling without use of tools.
Please take care to observe the recommended length tolerances of the chosen coupling, as an axial force on the pump will damage the pump.
3
1
C
2
B
A
1 = Nuts:
APP S 674 3.0-3.5: 40 ± 4 Nm / 30 ± 3 lbf ft
APP S 674 5.1-9.0: 40 ± 4 Nm / 30 ± 3 lbf ft
APP S 674 21-38: 40 ± 4 Nm / 30 ± 3 lbf ft
2 = Bolts:
APP S 674 3.0-3.5: 40 ± 4 Nm / 30 ± 3 lbf ft
APP S 674 5.1-9.0: 75 ± 5 Nm / 55 ± 3.5 lbf ft
APP S 674 21-38: 75 ± 5 Nm / 55 ± 3.5 lbf ft
3 = Torque, see table beside:
Thread size
M4
Torque (Nm)
1,5
M5
2
M6
4,8
M8 M10 M12
10 17 40
Torque (lbf)
1.1
1.5
3.5
7.4 12.5 29.5
3.2 Direction of rotation
The direction of rotation is indicated by an arrow at the pump label.
3.3 Orientation
The pump can be mounted/orientated in any horizontal direction; vertically only with the shaft pointing upwards.
180R9276 / 521B1245 / DKCFN.PI.013.Z1.02 / 03.2013
5
Instruction APP S 674 pumps
3.4 Connections
3.4.1 APP S 674 3.0-3.5
4 x M8 x 1.25
12 depth
Ø49.82 [1.961
]
6
Inlet
Outlet
Mounting of flange connections
Bolt torque: 30 ± 3 Nm
22 ± 2 lbf. ft
3.4.2 APP S 674 5.1-9.0
8 x M8 x 1.25
15 depth
Ø64 [2.52]
Outlet
180R9276 / 521B1245 / DKCFN.PI.013.Z1.02 / 03.2013
Inlet
Mounting of flange connections
Bolt torque: 30 ± 3 Nm
22 ± 2 lbf. ft
Instruction APP S 674 pumps
3.4.3 APP S 674 21-38
8 x M10 x 1.5
17 depth
Ø87 [3.425]
Inlet
Outlet
Mounting of flange connections
Bolt torque: 30 ± 3 Nm
22 ± 2 lbf. ft
4. Initial start-up
1. Flush inlet line before connecting the pump, to remove possible impurities from pipes, hoses etc.
2. Connect pump inlet to inlet line and flush the pump for 5 min. by using an internal flushing valve, to remove possible impurities from pipes, hoses etc.
3. Loosen top bleeding plug (see item 3.4) using an Allen key (only plugs with internal hexagan sockets). Retighten the plug, when water appears from the bleeding plug.
4. Make sure that the direction of rotation of the electric motor corresponds to the direction of rotation of the pump (see label on pump).
5. Now the pump is ready for start-up.
WARNING!
Make sure that the direction of rotation of the electric motor corresponds to the direction of rotation of the pump (see label on pump).
Otherwise the pump will be damaged if a check valve is placed between pump and feed pump.
4.1 APP S 674 3.0-3.5
4.2 APP S 674 5.1-9.0
Internal flushing valve Internal flushing valve
180R9276 / 521B1245 / DKCFN.PI.013.Z1.02 / 03.2013
7
Instruction APP S 674 pumps
4.3 APP S 674 21-38
5. Technical data
8
1)
2)
Pumps size
Outlet min. pressure, continuous
1)
Outlet max. pressure,
MAWP
Inlet operating pressure
2)
barg psig
Inlet design pressure
barg psig
Min. speed, continuous
Max. speed, continuous
Media temperatur
3)
rpm rpm
°C
°F
Ambient temperatur
barg psig barg psig
Storage temperature
Weight
°C
°F
°C
°F
Kg lb
APP S 674 3.0-3.5
20
290
80
1,160
0.5-10
7.25-145
15
217
700
3,000
2-50
36-122
0-50
32-122
-40 to +70
-40 to +158
15
33
APP S 674 5.1-9.0
30
435
80
1,160
2.0-10
29-145
15
217
700
1,800
2-50
36-122
0-50
32-122
-40 to +70
-40 to +158
40
88
For lower pressure, please contact Danfoss High Pressure Pumps
If inlet pressure exceeds inlet operating pressure, Danfoss recommends inspection of the pump and shaft seal
Dependent on the NaCl concentration
APP S 674 21-38
30
435
80
1,160
2.0-10
29-145
15
217
700
1,500
2-50
36-122
0-50
32-122
-40 to +70
-40 to +158
110
242
Inlet pressure:
If using lower inlet pressure than stated in above table, the pump will cavitate, which will damage the pump.
The inlet line connection must be properly tightened as entrance of air will cause cavitation.
Outlet pressure:
MAWP (Maximum Allowable Working Pressure) must be within specifications.
If pump operates below minimum outlet pressure, it may cause cavitation/erosion in the pump.
Note: We recommend that the pump unit includes a pressure gauge at inlet and outlet.
Dry running:
When running, the pump must always be connected with water supply in order to avoid pump damage.
Disconnection:
If inlet line is disconnected from the water supply, the pump will be emptied which will cause dry running.
When starting up again, follow the bleeding procedure described in section 4: Initial start-up.
180R9276 / 521B1245 / DKCFN.PI.013.Z1.02 / 03.2013
Instruction
6. Operation
80 º C
70
60
50
40
30
20
100
160
APP S 674 pumps
6.1 Temperature
In case of lower operating temperatures, please contact Danfoss High Pressure Pumps.
The chart below illustrates the corrosive resistance of different types of stainless steel related to NaCl concentration and temperature.
The APP S 674 pump is made of Super Duplex.
If the water pump is operated above the Super
Duplex line, always flush water pump with fresh water at operation stop in order to minimise the risk of crevice corrosion.
NaCl vs. temperature
316L
1000
1600
Duplex
Super Duplex
10 000
16000
100 000
160000
7. Long-term shutdown
For a long-term shutdown period, the SWRO system including the pump must be flushed with fresh water (permeate) to remove any salt.
It is recommended to make few turns on the pump to flush it properly.
8. Storage
When preparing the pump for long-term storage or for temperatures below the freezing point, flush the pump with an anti-freeze medium type monopropylene glycol to prevent internal corrosion or frost in the pump.
For furter information on anti-freeze media, please contact Danfoss High Pressure Pumps.
3. Connect the pump to a tank containing anti-freeze additive. Connect a hose to the inlet port of the pump and through another hose return the flow from the outlet port to the tank with anti-freeze additives.
4. Quickly start and stop the pump. Make
sure that the pump does not run dry. The pump is now protected against internal corrosion and frost.
Recommended procedure:
1. Disconnect water supply to the pump.
2. Through the lower bleeding plug, empty the pump housing for water and close it again.
180R9276 / 521B1245 / DKCFN.PI.013.Z1.02 / 03.2013
9
Instruction APP S 674 pumps
9. Service and warranty
Danfoss APP S 674 pumps are designed for long operation, low maintenance and reduced lifecycle costs.
Provided that the pump has been running according to the Danfoss specifications, Danfoss guarantees 8,000 hours service-free operation, however, max 18 months from date of production.
If Danfoss recommendations concerning system-design are not followed, it will strongly
influence the life of the APP S 674 pumps.
Maintenance:
After 8,000 hours of operation, it is strongly recommended to inspect the pump and change any worn parts, e.g. pistons. This is done in order to prevent a potential breakdown of the pump.
If the parts are not replaced, more frequent inspection is recommended according to our
service intervals.
Standstill:
The APP S 674 pumps are made of Super Duplex materials with excellent corrosion properties.
It is always recommended to flush the pump with freshwater when the system is shut down.
9.1 Repair
In case of irregular function of the APP S 674 pump, please contact Danfoss High Pressure
Pumps.
10
180R9276 / 521B1245 / DKCFN.PI.013.Z1.02 / 03.2013
Instruction APP S 674 pumps
9.2 Recommended service intervals
The recommended service intervals on the different parts in the APP S 674 pumps appear from the table below:
Position Qty. for all pump sizes
3.0-3.5
5.1-9.0
21-38
1 1 1
Description
1 Housing, main bearing
Material
Super Duplex,
PEEK
121
31
66
1
1
7
1
1
9
1
1
9
Port flange
Swash plate
Pistons Super Duplex,
PEEK
Service interval
No need for service
Super Duplex No wear part
Super Duplex 40,000 hours
Recommended inspection on a yearly basis; evaluate, if replacement is needed
92
91
61
1
1
1
1
1
1
1 Valve plate
1 Port plate
Super Duplex 24,000 hours
Super Duplex,
PEEK
24,000 hours
Super Duplex 40,000 hours
65 1 1
1 Cylinder barrel
1 Retainer plate
Super Duplex 24,000 hours
64
71
1 1
1
62
63
142
124
125
93
5, 123,
126, 127,
128,
133,147,
153
1
1
1
1
7
1
1
1
1
9
1 Retainer ball Super Duplex 40,000 hours
1 Retainer guide
Super Duplex,
PEEK
40,000 hours
4 Spring Hastelloy, C4 40,000 hours
Spring guide PEEK 40,000 hours
Super Duplex No wear part 1 Stop for shaft seal
1 Shaft seal
1 Flange for shaft seal
Hastelloy and
NBR/FFKM
It is good practice to change the seal after each disassembly of the pump
Super Duplex No wear part
9 Back-up ring
O-ring
(overall)
Screw
(overall)
Teflon
NBR
AISI 316
24,000 hours
24,000 hours
No wear part
152 1 1
Pin (overall)
Pin (overall)
AISI 316, PEEK
AISI 316,
Super Duplex
Super Duplex,
PEEK
No wear part
40,000 hours
134
3
67
2
1
2
1
1 Valve cone
(flushing valve)
Bleeding screw
4 Bleeding screw
1 Parallel key
Super Duplex No wear part
Super Duplex No wear part
AISI 316 40,000 hours
180R9276 / 521B1245 / DKCFN.PI.013.Z1.02 / 03.2013
11
10. EC Declaration of
Conformity
12
180R9276 / 521B1245 / DKCFN.PI.013.Z1.02 / 03.2013
Instruction APP S 674 pumps
180R9276 / 521B1245 / DKCFN.PI.013.Z1.02 / 03.2013
13
Instruction APP S 674 pumps
Danfoss A/S
High Pressure Pumps
DK-6430 Nordborg
Denmark
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice.
This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
14
180R9276 / 521B1245 / DKCFN.PI.013.Z1.02 / 03.2013