Connect Tech BlueStorm Multi-port Serial Adapter User manual

Add to My manuals
34 Pages

advertisement

Connect Tech BlueStorm Multi-port Serial Adapter User manual | Manualzz

BlueStorm/Express

User Manual

Connect Tech Inc

42 Arrow Road

Guelph, Ontario

N1K 1S6

Tel: 519-836-1291

Toll: 800-426-8979 (North America only)

Fax: 519-836-4878

Email: [email protected] [email protected]

Web: www.connecttech.com

CTIM-00033 Revision 0.11 Aug. 22, 2013

Connect Tech BlueStorm/Express User Manual

Table of Contents

Customer Support Overview .......................................................................................................................... 4

Contact Information........................................................................................................................................ 4

Limited Lifetime Warranty ............................................................................................................................. 5

Copyright Notice ............................................................................................................................................ 5

Trademark Acknowledgment ......................................................................................................................... 5

Introduction .................................................................................................................................................... 6

Features .......................................................................................................................................................... 6

BlueStorm/Express Diagrams......................................................................................................................... 7

Figure 1: BlueStorm/Express RS-232/422/485 two and four port model hardware components

(BEG001, BEG002, BEG003, BEG004) .................................................................................................................. 7

Figure 2: BlueStorm/Express RS-232/422/485 eight and 16 port model hardware components (BEG005, BEG006)

.................................................................................................................................................................................. 8

Figure 3: BlueStorm/Express Opto RS-232/422/485 four port model hardware components (BBG001) ................ 9

Figure 4: BlueStorm/Express Opto (1 kV) RS-232/422/485 eight port model hardware components (BBG003) .. 10

Figure 5: BlueStorm/Express LP Opto RS232/422/485 two port model hardware components (BCG001) ........... 10

Figure 6: BlueStorm/Express LP 8-Port RS232/422/485 hardware components (BFG001/BFG002) .................... 11

Figure 7: BlueStorm/Express Isolated 8-Port RS232 hardware components (BDG001) ........................................ 11

Figure 8: BlueStorm/Express Isolated 4-Port RS232/422/485 Low Profile (BCG004) .......................................... 12

BlueStorm/Express Installation Overview ....................................................................................................13

Hardware Configuration ................................................................................................................................13

Interrupts and Memory Address Selection .............................................................................................................. 13

Electrical Interfaces .......................................................................................................................................13

RS-232 Electrical Interface ..................................................................................................................................... 13

RS-422/485 Electrical Interface .............................................................................................................................. 13

Full Duplex Mode ............................................................................................................................................13

Half Duplex Mode ...........................................................................................................................................14

Multi-drop Mode ..............................................................................................................................................14

Line Bias/Termination .....................................................................................................................................14

Jumper Block Settings ............................................................................................................................................ 14

Figure 8: Example of various port configuration jumper block settings ................................................................. 14

Tri-state Operation .................................................................................................................................................. 15

BCG004: BlueStorm/Express, Isolated, 4-Port, Low-Profile ........................................................................16

Connector Pinouts .........................................................................................................................................17

Table 1: DB-9 Male Pinouts - TYPE A ...................................................................................................................17

Table 2: RJ-45 Pinouts – TYPE B ...........................................................................................................................17

Table 3: DB-9 Male Pinouts - TYPE B ....................................................................................................................18

Table 4: DB-37 ........................................................................................................................................................18

Table 5: VHDCI-68 .................................................................................................................................................19

Table 6: HDB-78......................................................................................................................................................21

Table 7: HDB-62 Connector Pinout .........................................................................................................................23

Table 8: HDB-44 (BCG004) ....................................................................................................................................25

RS-422/485 Recommended Wiring ...............................................................................................................26

Type “A” RS-422/485 Wiring ................................................................................................................................ 26

Type “B” RS-422/485 Wiring ................................................................................................................................. 26

Hardware Installation ....................................................................................................................................27

Installing the BlueStorm/Express into Your System ............................................................................................... 27

Software Installation ......................................................................................................................................27

Software First Installation ....................................................................................................................................... 27

Hardware First Installation ...................................................................................................................................... 28

Windows XP Installation ........................................................................................................................................ 28

Port Settings ............................................................................................................................................................ 29

Advanced Port Settings ........................................................................................................................................... 30

Use FIFO Buffers .............................................................................................................................................30

Receive and Transmit FIFO Settings ...............................................................................................................30

Software Settings for RS-422/485........................................................................................................................... 30

Baud Rate Mapping .........................................................................................................................................31

Clock Frequency ..............................................................................................................................................31

COM Number ..................................................................................................................................................31

Specifications ................................................................................................................................................32

2 Revision 0.11

Connect Tech BlueStorm/Express User Manual

Operating Environment ........................................................................................................................................... 32

PCI Express Interface.............................................................................................................................................. 32

Communications ..................................................................................................................................................... 32

Baud Rates .......................................................................................................................................................32

UARTs .............................................................................................................................................................33

Surge Suppression ................................................................................................................................................... 33

Isolation Ratings ..................................................................................................................................................... 33

Dimensions ............................................................................................................................................................. 33

Certification ...................................................................................................................................................34

Revision 0.11 3

Connect Tech BlueStorm/Express User Manual

Customer Support Overview

If you experience difficulties after reading the manual and/or using the product, contact the

Connect Tech reseller from which you purchased the product. In most cases the reseller can help you with product installation and difficulties.

In the event that the reseller is unable to resolve your problem, our highly qualified support staff can assist you. Our support section is available 24 hours a day, 7 days a week on our website at: www.connecttech.com/sub/support/support.asp.

See the contact information section below for more information on how to contact us directly. Our technical support is always free.

Contact Information

We offer three ways for you to contact us:

Mail/Courier

You may contact us by letter at:

Connect Tech Inc.

Technical Support

42 Arrow Road

Guelph, Ontario

Canada N1K 1S6

Email/Internet

You may contact us through the Internet. Our email and URL addresses on the Internet are: [email protected] [email protected] www.connecttech.com

Note:

Please go to the Download Zone or the

Knowledge Database

in the

Support Center

on the Connect

Tech website for product manuals, installation guides, device driver software and technical tips.

Submit your technical support questions to our customer support engineers via the

Support Center on the Connect Tech website.

Telephone/Facsimile

Technical Support representatives are ready to answer your call Monday through Friday, from

8:30 a.m. to 5:00 p.m. Eastern Standard Time. Our numbers for calls are:

Toll Free: 800-426-8979 (North America only)

Telephone: 519-836-1291 (Live assistance available 8:30 a.m. to 5:00 p.m. EST,

Monday to Friday)

Facsimile: 519-836-4878 (on-line 24 hours)

4 Revision 0.11

Connect Tech BlueStorm/Express User Manual

Limited Lifetime Warranty

Connect Tech Inc. provides a Lifetime Warranty for all Connect Tech Inc. products. Should this product, in Connect Tech Inc.'s opinion, fail to be in good working order during the warranty period, Connect Tech Inc. will, at its option, repair or replace this product at no charge, provided that the product has not been subjected to abuse, misuse, accident, disaster or non-Connect Tech

Inc. authorized modification or repair.

You may obtain warranty service by delivering this product to an authorized Connect Tech Inc. business partner or to Connect Tech Inc. along with proof of purchase. Product returned to

Connect Tech Inc. must be pre-authorized by Connect Tech Inc. with an RMA (Return Material

Authorization) number marked on the outside of the package and sent prepaid, insured and packaged for safe shipment. Connect Tech Inc. will return this product by prepaid ground shipment service.

The Connect Tech Inc. Lifetime Warranty is defined as the serviceable life of the product. This is defined as the period during which all components are available. Should the product prove to be irreparable, Connect Tech Inc. reserves the right to substitute an equivalent product if available or to retract Lifetime Warranty if no replacement is available.

The above warranty is the only warranty authorized by Connect Tech Inc. Under no circumstances will Connect Tech Inc. be liable in any way for any damages, including any lost profits, lost savings or other incidental or consequential damages arising out of the use of, or inability to use, such product.

Copyright Notice

The information contained in this document is subject to change without notice. Connect Tech

Inc. shall not be liable for errors contained herein or for incidental consequential damages in connection with the furnishing, performance, or use of this material. This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Connect Tech, Inc.

Copyright

1997 - 2009 by Connect Tech, Inc.

Trademark Acknowledgment

Connect Tech, Inc. acknowledges all trademarks, registered trademarks and/or copyrights referred to in this document as the property of their respective owners.

Not listing all possible trademarks or copyright acknowledgments does not constitute a lack of acknowledgment to the rightful owners of the trademarks and copyrights mentioned in this document.

Revision 0.11 5

Connect Tech BlueStorm/Express User Manual

Introduction

Connect Tech's BlueStorm/Express family offers compatibility with the next generation in computer bus standards. Available in two, four, eight and sixteen ports, these x1 lane PCI Express serial cards make it easy to add a wide variety of serial communications options to computers with a PCI Express bus. Your existing serial peripherals can connect directly to the BlueStorm/Express serial card, using legacy application software from your PCI system.

Instead of relying on shared parallel bus architecture, PCI Express is built around bidirectional, dedicated point-to-point “lanes.” This technology allows extensive future scalability. With the future in mind, Connect Tech designed the BlueStorm/Express to ensure compatibility with future versions of the PCI Express bus.

The BlueStorm/Express is perfect for a variety of applications such as retail/point of sale, automated teller machines, transportation stations, lottery terminals and self-service kiosks, among others.

Features

2, 4, 8, or 16 hardware switchable RS-232/422/485 ports x1 lane PCI Express, compatible with any PCI Express slot width

Supports full duplex (four wire) with RTS/CTS flow control, half duplex (two wire) with auto

TxD echo cancellation and multi-drop (four wire) communication modes in RS-422/485

Bidirectional data communication speeds to 1.8432 Mbps in RS-422/485 and

921.6 Kbps in RS-232

Hardware selectable for tri-state on power-up in RS-485 modes (applies to two and four port

BlueStorm/Express cards and the BlueStorm/Express Opto)

Surge suppression on every signal of every port

Operating temperature range of 0ºC to 70ºC

Software support for QNX 4.X/6.X, Linux, Windows 2000/CE/XP/XP x64/XPe/Server

2003/Server 2003 x64/Vista/7

Plug and play - no jumpers to set for memory or interrupt configuration

Isolation available on select models: o BBG001, BCG001:

 3 kV rating of isolation for all signals port-to-port and on the board o BBG003:

 1 kV rating of isolation for all signals port-to-port and on the board o BDG001:

 2 kV rating of isolation for all signals port-to-port through cable and 3kV rating on the board

6 Revision 0.11

Connect Tech BlueStorm/Express User Manual

BlueStorm/Express Diagrams

Figure 1: BlueStorm/Express RS-232/422/485 two and four port model hardware components

(BEG001, BEG002, BEG003, BEG004)

Note: The above example is a four port BlueStorm/Express model. JC and JD headers will not be installed on two port models.

Revision 0.11 7

Connect Tech BlueStorm/Express User Manual

Figure 2: BlueStorm/Express RS-232/422/485 eight and 16 port model hardware components

(BEG005, BEG006)

Note: The above example is a 16 port BlueStorm/Express model. Headers JI through JP will not be installed on eight port models

8 Revision 0.11

Connect Tech BlueStorm/Express User Manual

Figure 3: BlueStorm/Express Opto RS-232/422/485 four port model hardware components

(BBG001)

Note: The above example is a four port BlueStorm/Express Opto model installed with headers JA through JD.

Revision 0.11 9

Connect Tech BlueStorm/Express User Manual

Figure 4: BlueStorm/Express Opto (1 kV) RS-232/422/485 eight port model hardware components

(BBG003)

Note: The above example is an eight port model where ports 5 through 8 feature

1 kV optical isolation and ports 1 through 4 are non-isolated.

Figure 5: BlueStorm/Express LP Opto RS232/422/485 two port model hardware components

(BCG001)

Port 1

Port 2

10 Revision 0.11

Connect Tech BlueStorm/Express User Manual

Figure 6: BlueStorm/Express LP 8-Port RS232/422/485 hardware components

(BFG001/BFG002)

Figure 7: BlueStorm/Express Isolated 8-Port RS232 hardware components

(BDG001)

This board requires no jumpers.

Revision 0.11 11

Connect Tech BlueStorm/Express User Manual

Figure 8: BlueStorm/Express Isolated 4-Port RS232/422/485 Low Profile

(BCG004)

Refer to the “BCG004: BlueStorm/Express, Isolated, 4-Port, Low-Profile” section below, for details about

the settings of the mode switch.

Refer to “Table 8: HDB-44 (BCG004)” for IO connector signal pin out.

12 Revision 0.11

Connect Tech BlueStorm/Express User Manual

BlueStorm/Express Installation Overview

Before you begin, take a moment to ensure your package includes the components that ship with your product. These components should include:

One BlueStorm/Express adapter

One CD containing software and documentation

One DB-9 male fan-out cable or other custom cable assembly (optional)

If any of these components are missing, contact Connect Tech

(see more Contact Details ) or your

reseller.

There are three stages to installing your BlueStorm/Express:

1.

Hardware Configuration

Interrupts and Memory selection will be set by the host computer’s BIOS and operating system. This section outlines jumper settings and configuration.

2.

Hardware Installation

Installation involves the physical installation of the BlueStorm/Express into your computer.

Please note that you should configure any jumper settings prior to installing the board.

(If you choose to use the Windows Software First installation option, go to Section 3 before

Section 2.)

3.

Software/Driver Installation

Load the appropriate driver for your Operating System, as found on the accompanying CD.

Installation guides are also available on the CD to aid you in this process. Please note that

Windows users have two options for software installation:

Software First installations require that you install your drivers prior to installing the hardware into your system.

Hardware First installations require the installation of the drivers when prompted by the operating system’s hardware detection process after the hardware installation.

Hardware Configuration

Interrupts and Memory Address Selection

The BlueStorm/Express board is a PCI Express card, so the host computer’s BIOS will automatically set interrupts and memory addresses when you power up the system.

Electrical Interfaces

RS-232 Electrical Interface

This is the default setting for the selectable interface of the BlueStorm/Express. To operate a port in RS-232 mode, no jumpers are set on the corresponding jumper block.

RS-422/485 Electrical Interface

The BlueStorm/Express models with support for RS-422/485 interface offer three modes of RS-

422/485 communication, as outlined below. (See Figure 8

to see examples of jumper settings.)

Full Duplex Mode

In this mode, TxD+/- is being driven to a known level all the time. This mode is typically used in point-to-point situations much like RS-232. It is the default setting for RS-422/485 mode.

Revision 0.11 13

Connect Tech BlueStorm/Express User Manual

Half Duplex Mode

In this mode the TxD+/- line driver is enabled only when data is transmitted and RxD+/- is disabled when data is being transmitted. This mode is typically used in either point-to-point 2-wire connections OR in multi-drop 2-wire bus connections. This mode requires software setup in

Control Panel – System – Hardware – Device Manager – Ports – CTI PCI Express UART. Click on

Advanced under Port Settings after the driver is installed. (See

Port Settings ).

Multi-drop Mode

In this mode the TxD+/- line driver is enabled only when data is transmitted and RxD+/- is enabled all the time. This mode is typically used in multi-drop 4-wire connections. This mode requires software setup in Control Panel – System Properties – Hardware – Device Manager – Ports –

CTI PCI Express UART. Click on Advanced under Port Settings. (See Half Duplex Mode above.)

Line Bias/Termination

The RS-422/485 transceivers transmit and receive, are optionally biased to produce a line level mark condition through jumper selectable resistors. These options are typically used in multi-drop

4-wire connections.

Jumper Block Settings

The following jumper block diagram depicts typical settings on a four-port selectable

BlueStorm/Express. Jumper blocks JA and JB control ports 1 and 2, JC and JD control ports 3 and

4, respectively. (See Figures 1 to 7

for location of jumper blocks.)

Figure 8: Example of various port configuration jumper block settings

In this example, Port 1(JA) is set to RS-232, Port 2 (JB) is set to RS-422/485 half duplex, Port 3 (JC) is set to RS-422/485 full duplex, and Port 4 (JD) is set to RS-422/485 multi-drop.

RS-485 Selection: Install this jumper to configure a port for RS-422/485 mode. If the jumper is not installed, the port will function in RS-232 mode. (All jumpers should be removed from any port operating in RS-232 mode.)

TxD Control: Install this jumper to enable the RS-485 transmitter only when sending data. This mode is useful for half-duplex operation when only one device is allowed to send data at a time. If the jumper is not installed, the transmitter will always drive the line to an idle state when not sending data.

RxD control: Install this jumper to enable the RS-485 receiver only when NOT transmitting data.

This is useful for half-duplex operation to prevent the transmitting device from receiving the data it has sent. If this jumper is not installed, the receiver is always enabled and ready to receive data.

RxD ± Termination/Bias: Install this pair of jumpers to enable a 150 Ohm terminator across the

RxD+ and RxD- pins for the corresponding port. A biasing network is also enabled that drives the receiver to an inactive or safe mode. The receiver can still receive data from another device and the biasing helps to prevent the reception of data generated by noise on the transmission line. The two jumpers for RxD termination/bias must be installed and removed as a pair.

14 Revision 0.11

Connect Tech BlueStorm/Express User Manual

TxD ± Termination: Install this jumper to enable a 150 Ohm resistor across the TxD+ and TxD- pins of the corresponding port.

Half Duplex and Multi-drop modes require you to select the appropriate mode via

software. Please refer to the readme.txt files found in the appropriate directories on the CD.

Tri-state Operation

Jumper block J2 (see Figure 1 for an example) controls Tx tri-state on boot for ports configured in

RS-485 half duplex or multi-drop modes. This jumper block will have no effect on ports configured as RS-232 or RS-485 full duplex.

For BlueStorm/Express 2/4 port cards, jumpering position 1 disables tri-state on boot for ports 1 and 2. Jumpering position 2 disables tri-state on boot for ports 3 and 4.

For BlueStorm/Express Opto and BlueStorm/Express LP Opto cards, jumpering position 1 enables tri-state on boot for ports 1 and 2. Jumpering position 2 enables tri-state on boot for ports 3 and 4.

Jumper block J1 is used in diagnostic modes and should be left unpopulated unless directed otherwise by Connect Tech’s technical support in the diagnosing of a system problem.

Power-On Tri-state (BlueStorm/Express Opto 1 kV model only)

BlueStorm/Express Opto 1 kV models offer a power-on tri-state similar to the Auto-485 mode selection listed above. The BlueStorm/Express Opto 1kV will tri-state ports configured as RS-485 half duplex or multi-drop slave.

Jumper J1 controls the power-on tri-state functionality. Install a jumper on the first location of the

J1 in order to tri-state Port 1 at power-on. Install a jumper on the second position for Port 2, etc.

The ports will not come out of tri-state until the driver begins transmitting on the associated port.

Installing a jumper on J1 will have no effect on ports configured in RS-232 mode.

Half Duplex and Multi-drop Slave modes require you to select the appropriate mode via software. Please refer to the readme.txt files found in the appropriate directories on the

BlueStorm/Express CD.

Revision 0.11 15

Connect Tech BlueStorm/Express User Manual

BCG004: BlueStorm/Express, Isolated, 4-Port, Low-Profile

Each Port has a 4-Position switch which sets the mode for the Port. Positions #1&2 set the basic mode for the port. Positions #3&4 perform other setup functions.

M0 M1 Mode

OFF OFF Loopback

ON OFF RS232

OFF ON RS485

ON ON RS422

Term Function

ON 120 ohm Receiver termination enabled

OFF Termination disabled

Slow Slew

ON

Function

Slow Slew Rate enabled

OFF Slow Slew Rate disabled

Notes:

1. Loopback mode connects TXRX / RTSCTS,DSR,RI / DTRDCD at the Line Interface device, and can be used to test the board operation through all isolators.

2. The termination function only works in RS422 or RS485 mode.

3. Slow slew rate works in any mode except loopback.

4. All switch settings can be over-ridden by software (switches can be left in any position when software control is used). The board will power-up with the settings established by the switches, prior to software controlling the settings.

16 Revision 0.11

Connect Tech BlueStorm/Express User Manual

Connector Pinouts

Table 1: DB-9 Male Pinouts - TYPE A

This “TYPE A” DB-9 pinout applies only to the following Part Numbers:

BEG001, BEG002, BEG003, BEG004, BEG005, BEG006, BBG003, BFG001, BFG002, BDG001

Pin No.

4

5

6

1

2

3

7

8

9

RS-232

Signal Direction

RS-422/485

Signal

DCD

RxD

TxD input input output

RxD B(+)

TxD B(+)

TxD A(-)

DTR

SG output

DSR * input

RxD A(-) signal gnd SR

CTS A(-)

RTS

CTS

RI * output input input

RTS A(-)

RTS B(+)

CTS B(+)

Male DB-9 Connector

Direction input output output input signal ref. input output output input

1

6 9

5

* DSR and RI signals not available on the BDG001

Table 2: RJ-45 Pinouts – TYPE B

This “TYPE B” RJ-45 pinout applies only to the following Part Numbers:

BBG001, BCG001

Pin No.

4

5

6

1

2

3

7

8

9

10

RS-232

Signal

N/C

N/C

RTS

SG

TxD

RxD

Gnd

CTS

N/C

N/C

Direction

RS-422/485

Signal no connect RTS (-) input RxD (+) output RTS (+) signal gnd SR output TxD (+) input RxD (-) ground input

Gnd.

CTS (+) no connect TxD (-) no connect CTS (-)

RJ-45 connector

Direction output input output signal ref. output input ground input output input

1 10

Using the cable CAGRJ4509 will send the RJ45 signals to DB-9 male

“TYPE B” connectors. See below for the DB-9 “TYPE B” pinouts.

Revision 0.11 17

Connect Tech BlueStorm/Express User Manual

Table 3: DB-9 Male Pinouts - TYPE B

This “TYPE B” DB-9 pinout applies only to the following Part Numbers:

BBG001, BCG001

8

9

3

4

5

6

7

Pin No.

1

2

RS-232

Signal

N/C

RxD

TxD

N/C

SG

N/C

RTS

CTS

N/C

Direction

RS-422/485

Signal no connect RxD (+) input RxD (-) output TxD (+) no connect TxD (-) signal gnd SR no connect CTS (-) output RTS (+) input CTS (+) no connect RTS (-)

Male DB-9 Connector

Direction input input output output signal ref. input output input output

1

6 9

5

Table 4: DB-37

This DB-37 Connector pinout applies only to the following Part Numbers:

BEG002, BEG004

Port

No.

4

4

4

4

4

2

2

2

2

3

3

3

3

1

1

1

3

2

2

2

2

2

1

4

4

4

4

3

3

3

3

1

1

1

1

1

RS-232

Signal

SG

DTR

TxD

RxD

DCD

RI

CTS

RTS

DSR

CTS

RTS

DSR

SG

DTR

TxD

RxD

DCD

RI

CTS

RTS

DSR

SG

DTR

TxD

RxD

DCD

RI

SG

DTR

TxD

RxD

DCD unused

RI

CTS

RTS

DSR

Pin

No.

29

30

31

32

33

34

35

36

37

25

26

27

28

21

22

23

24

15

16

17

18

19

20

11

12

13

14

7

8

9

10

1

2

3

4

5

6

Direction

RS-422/485

Signal signal gnd SR output RxD A(-) output input input

TxD A(-)

TxD B(+)

RxD B(+) unused input input output input

CTS B(+)

RTS B(+)

RTS A(-)

CTS A(-) input input output input

CTS B(+)

RTS B(+)

RTS A(-)

CTS A(-) signal gnd SR output RxD A(-) output input input input

TxD A(-)

TxD B(+)

RxD B(+)

CTS B(+) input output

RTS B(+)

RTS A(-) input CTS A(-) signal gnd SR output output input input

RxD A(-)

TxD A(-)

TxD B(+)

RxD B(+) signal gnd SR output RxD A(-) output input input

TxD A(-)

TxD B(+)

RxD B(+) input input output input

CTS B(+)

RTS B(+)

RTS A(-)

CTS A(-)

Direction output output input signal ref input output output input signal ref input output output input input output output

Input signal ref input output output input input output output input input output output input signal ref input output output input input

18 Revision 0.11

Connect Tech BlueStorm/Express User Manual

Pin

No.

Port

No.

1 1

Table 5: VHDCI-68

This VHDCI-68 Connector pinout applies only to the following Part Numbers:

BEG005, BEG006, BFG001, BFG002

RS-232

Signal

TXD

Signal

Direction output

RS-422/485

Signal

TXD-

Signal

Direction output

2 1

3 1

4 1

5 1

6 1

7 1

8 1

9 2

10 2

11 2

12 2

13 2

14 2

RI

DCD

DTR

RTS

DSR

RXD

CTS

TXD

RI

DCD

DTR

RTS

DSR input input output output input input input output input input output output input

CTS+

RXD+

RXD-

RTS-

CTS-

TXD+

RTS+

TXD-

CTS+

RXD+

RXD-

RTS-

CTS- input input input output input output output output input input input output input

15 2

16 2

RXD

CTS

17 1, 2 SG

18 3, 4 SG

19 3 TXD

20 3 RI

21 3

22 3

23 3

24 3

25 3

DCD

DTR

RTS

DSR

RXD

26 3

27 4

28 4

29 4

CTS

TXD

RI

DCD input input signal gnd. signal gnd. output input input output output input input input output input input

TXD+

RTS+

SR

SR

TXD-

CTS+

RXD+

RXD-

RTS-

CTS-

TXD+

RTS+

TXD-

CTS+

RXD+ output output signal ref. signal ref. output input input input output input output output output input input

Revision 0.11 19

Connect Tech BlueStorm/Express User Manual

Pin

No.

Port

No.

30 4

31 4

32 4

33 4

34 4

35 5

36 5

37 5

38 5

39 5

40 5

41 5

42 5

43 6

44 6

45 6

RXD

CTS

TXD

RI

DCD

46 6

47 6

48 6

DTR

RTS

DSR

49 6

50 6

RXD

CTS

51 5, 6 SG

RS-232

Signal

DTR

RTS

DSR

RXD

CTS

TXD

RI

DCD

DTR

RTS

DSR

52 7, 8 SG

53 7 TXD

54 7 RI

55 7

56 7

DCD

DTR

57 7

58 7

59 7

60 7

61 8

62 8

63 8

64 8

RTS

DSR

RXD

CTS

TXD

RI

DCD

DTR

65 8

66 8

67 8

68 8

RTS

DSR

RXD

CTS

Table 5: VHDCI-68 Female Pinouts

(continued) signal gnd. output input input output output input input input output input input output output input input input

Signal

Direction output output input input input output input input output output input input input output input input output output input input input signal gnd.

SR

TXD-

CTS+

RXD+

RXD-

RTS-

CTS-

TXD+

RTS+

TXD-

CTS+

RXD+

RXD-

RTS-

CTS-

TXD+

RTS+

TXD+

RTS+

TXD-

CTS+

RXD+

RXD-

RTS-

CTS-

TXD+

RTS+

SR

RS-422/485

Signal

RXD-

RTS-

CTS-

TXD+

RTS+

TXD-

CTS+

RXD+

RXD-

RTS-

CTS- signal ref. output input input input output input output output output input input input output input output output

Signal

Direction input output input output output output input input input output input output output output input input input output input output output signal ref.

20 Revision 0.11

Connect Tech BlueStorm/Express User Manual

Table 6: HDB-78

This HDB-78 Connector pinout applies only to the following Part Numbers:

BBG003

Port

No.

6

6

6

5

5

6

8

5

5

8

8

8

7

7

7

6

7

7

6

6

6

5

5

5

5

5

8

8

1

1

8

8

8

1

1

1

2

2

7

7

6

7

7

RS-232

Signal

RTS

CTS

NC

NC

NC

NC

TxD

RxD

NC

NC

SG

TxD

RxD

NC

NC

RTS

CTS

NC

NC

SG

RTS

CTS

NC

NC

SG

RTS

CTS

NC

NC

TxD

RxD

NC

NC

NC

TxD

RxD

NC

NC

SG

RTS

CTS

DSR

RI

SG

RTS

CTS

Pin

No.

23

24

25

26

27

28

15

16

17

18

19

20

21

22

9

10

11

12

13

14

6

7

8

1

2

3

4

5

35

36

37

38

39

40

41

42

43

29

30

31

32

33

34

44

45

46

Signal

Direction

RS-422/485

Signal

Signal

Direction output input

RTS A(-) output

RTS B(+) output no connect CTS A(-) input no connect CTS B(+) input signal gnd. SR signal ref. output input

RTS A(-) no connect CTS A(-) output

RTS B(+) output input no connect CTS B(+) input output RTS A(-) output input RTS B(+) output no connect CTS A(-) input no connect CTS B(+) input signal gnd. SR signal ref. output input

RTS A(-) no connect CTS A(-) output

RTS B(+) output input no connect CTS B(+) input no connect NC no connect no connect NC output TxD A(-) input no connect output

TxD B(+) output no connect RxD A(-) input no connect RxD B(+) input signal gnd. SR signal ref. output input

TxD A(-) no connect RxD A(-) output

TxD B(+) output input no connect RxD B(+) input output TxD A(-) output input TxD B(+) output no connect RxD A(-) input no connect RxD B(+) input no connect NC no connect output input

TxD A(-) no connect RxD A(-) output

TxD B(+) output input no connect RxD B(+) input signal gnd. SR signal ref. output input

RTS A(-)

RTS B(+) output output input input

CTS A(-) input

CTS B(+) input signal gnd. SR output RTS A(-) input signal ref. output

RTS B(+) output

Revision 0.11 21

Connect Tech BlueStorm/Express User Manual

2

2

2

1

2

2

1

1

1

4

4

4

4

3

3

3

3

3

Port

No.

2

2

3

3

3

3

4

4

4

4

4

63

64

65

66

67

68

57

58

59

60

61

62

49

50

51

52

53

54

55

56

Pin

No.

47

48

69

70

71

72

73

74

75

76

77

78

Table 6: HDB-78 Pinout

(continued)

RI

NC

NC

TxD

RxD

DTR

DCD

SG

TxD

RxD

DTR

DCD

RS-232

Signal

DSR

RI

RTS

CTS

DSR

RI

SG

RTS

CTS

DSR

TxD

RxD

DTR

DCD

SG

TxD

RxD

DTR

DCD

NC

Signal

Direction input input

RS-422/485

Signal

Signal

Direction

CTS A(-) input

CTS B(+) input output input input input

RTS A(-)

RTS B(+) output

CTS A(-)

CTS B(+) signal gnd. SR output input input signal ref. output input input

RTS A(-)

RTS B(+)

CTS A(-) output output input input no connect no connect output input output

CTS B(+) input

NC no connect

NC no connect

TxD A(-) output

TxD B(+) output

RxD A(-) input input RxD B(+) input signal gnd. SR signal ref. output TxD A(-) output input output input

TxD B(+)

RxD A(-)

RxD B(+) output input input output input output input

TxD A(-)

RxD A(-) signal gnd. SR output TxD A(-) output

TxD B(+) output input

RxD B(+) input signal ref. output input output input no connect

TxD B(+) output

RxD A(-) input

RxD B(+) input

NC no connect

22 Revision 0.11

Connect Tech BlueStorm/Express User Manual

4

5

6

7

1

2

3

8

9

1

2

7

8

9

3

4

5

6

5

6

7

8

1

2

3

4

9

6

7

8

2

3

4

5

9

7

8

9

3

4

5

6

1

DB-9

Pin No.

1

2

Table 7: HDB-62 Connector Pinout

This HDB-62 Connector pinout applies only to the following Part Numbers:

BDG001

Port

No.

1

2

3

4

5

41

20

61

18

60

NC

40

19

NC

26

5

46

3

45

NC

25

4

NC

28

7

29

27

48

NC

49

6

NC

10

51

8

50

NC

30

9

NC

DB-62

Pin No.

33

12

34

32

53

NC

54

11

NC

31

Input

Input

Output

Output

N/A

-

Output

Input

-

Input

Input

Output

Output

N/A

-

Output

Input

-

Input

Output

Output

N/A

-

Output

Input

-

Input

Input

Output

Output

N/A

-

Output

Input

-

Signal

Direction RS-232 Signal

Input

Input

DCD

RX

Output

Output

N/A

-

Output

Input

-

Input

TX

DTR

GND

-

RTS

CTS

-

DCD

RX

TX

DTR

GND

-

RTS

CTS

-

DCD

RX

TX

DTR

GND

-

RTS

CTS

-

DCD

RX

TX

DTR

GND

-

RTS

CTS

-

DCD

RX

TX

DTR

GND

-

RTS

CTS

-

Revision 0.11 23

Connect Tech BlueStorm/Express User Manual

Port

No.

6

7

8

8

9

1

2

4

5

6

7

DB-9

Pin No.

1

2

3

6

7

8

2

3

4

5

9

6

7

8

9

3

4

5

1

Table 7: HDB-62 Connector Pinout

(continued)

22

43

NC

44

1

NC

38

17

DB-62

Pin No.

23

2

24

15

56

13

55

NC

35

14

NC

39

37

58

NC

59

16

NC

36

Output

Output

N/A

-

Output

Input

-

Input

Input

Output

Output

N/A

-

Output

Input

-

Signal

Direction RS-232 Signal

Input

Input

Output

DCD

RX

TX

Output

N/A

-

Output

Input

-

Input

Input

DTR

GND

-

RTS

CTS

-

DCD

RX

RX

TX

DTR

GND

-

RTS

CTS

-

TX

DTR

GND

-

RTS

CTS

-

DCD

24 Revision 0.11

Connect Tech BlueStorm/Express User Manual

1

2

3

4

5

6

7

8

9

4

5

6

1

2

3

7

8

9

1

2

3

4

5

6

7

8

9

DB-9

Pin No.

4

5

6

1

2

3

7

8

9

4

Table 8: HDB-44 (BCG004)

DB-9 Pin-outs are achieved using cable CTIC-00359

Port

No.

1

2

3 11

25

9

26

39

24

10

40

41

7

21

5

22

35

20

6

36

37

15

29

13

30

43

28

14

44

---

HDB-44

Pin No.

3

17

1

18

31

16

2

32

33

DCD

RX

TX

DTR

GND

DSR

RTS

CTS

RI

DCD

RX

TX

DTR

GND

DSR

RTS

CTS

RI

RS-232

Signal

DCD

RX

TX

DTR

GND

DSR

RTS

CTS

RI

DCD

RX

TX

DTR

GND

DSR

RTS

CTS

RS422

Signal

RS485

Signal

TX+ TXRX+

RX+

GND

TX-

GND

TXRX-

RX-

TX+ TXRX+

RX+

GND

TX-

GND

TXRX-

RX-

TX+ TXRX+

RX+

GND

TX-

GND

TXRX-

RX-

TX+ TXRX+

RX+

GND GND

TX-

RX-

TXRX-

Note:

Cable CTIC-00359 is especially purposed for use with the BCG004 board, maintaining the isolation rating and giving the DB-9 pins-outs above.

Revision 0.11 25

Connect Tech BlueStorm/Express User Manual

RS-422/485 Recommended Wiring

Type “A” RS-422/485 Wiring

This wiring scheme can be applied to the following Part Numbers:

BEG001, BEG002, BEG003, BEG004, BEG005, BEG006, BBG003, BFG001, BFG002

RS-422/485

2 Wire Diagram

RS-422/485

4 Wire Diagram

BlueStorm/Express

Adapter

RS-422/485

Peripheral

BlueStorm/Express

Adapter

RS-422/485

Peripheral

8

9

7

6

5

1

2

3

4

RxD +

TxD +

TxD -

RxD -

RTS +

CTS +

RTS -

CTS -

SR

TxD +

RxD +

RxD -

TxD -

RTS +

CTS +

RTS -

CTS -

SR

2

3

1

4

8

9

7

6

5

TxD +

TxD -

RxD +

RxD -

RTS +

CTS +

RTS -

CTS -

SR

RxD +

RxD -

TxD +

TxD -

RTS +

CTS +

RTS -

CTS -

SR

Type “B” RS-422/485 Wiring

This wiring scheme can be applied to the following Part Numbers:

BBG001, BCG001

RS-422/485

2 Wire Diagram

RS-422/485

4 Wire Diagram

BlueStorm/Express Opto

Adapter

RS-485/422

Peripheral

BlueStorm/Express Opto

Adapter

RS-422/485

Peripheral

1

3

4

2

7

8

9

6

5

RxD +

TxD +

TxD -

RxD -

RTS +

CTS +

RTS -

CTS -

SR

TxD +

RxD +

RxD -

TxD -

RTS +

CTS +

RTS -

CTS -

SR

3

4

1

2

9

6

5

7

8

TxD +

TxD -

RxD +

RxD -

RTS +

CTS +

RTS -

CTS -

SR

RxD +

RxD -

TxD +

TxD -

RTS +

CTS +

RTS -

CTS -

SR

26 Revision 0.11

Connect Tech BlueStorm/Express User Manual

Hardware Installation

Installing the BlueStorm/Express into Your System

Turn off the power to your computer and open it to expose the expansion slots (consult your system’s documentation for more information on this procedure).

Jumper all of the ports to the desired line interface and termination.

Choose an available PCI Express position and gently press the card into the slot.

Software Installation

Software First Installation

Find the driver install package on your CD and run DpInst.exe in the directory. The installer will guide you through the process. The board will then be detected and installed when the board is physically added to the system. Software First installs are a great way to update existing drivers.

Connect Tech provides QNX 4.X/6.X, Linux, Windows 2000/CE/XP/XP x64/XPe/Server

2003/Server 2003 x64, and Vista support for BlueStorm/Express.

Revision 0.11 27

Connect Tech BlueStorm/Express User Manual

Hardware First Installation

The BlueStorm/Express provides support for QNX 4.X/6.X, Linux, Windows 2000/CE/XP/XP x64/XPe/Server 2003/Server 2003 x64 and Vista. Please refer to the readme.txt

files found in the appropriate directories on the CD containing drivers and documentation. These files contain technical tips or release notes concerning installation and configuration of the device driver. For further information concerning software installation of BlueStorm/Express products please visit the Connect Tech website at www.connecttech.com.

If you are interested in a device driver for an operating system not listed please contact the

Connect Tech Sales Department . Also, visit the Download Zone of the Support Center on the

Connect Tech website for the latest product manuals, installation guides, diagnostic utilities and device driver software.

Windows XP Installation

The following instructions outline how to install the BlueStorm/Express to a computer running

Windows XP. For other operating system installations, consult the readme.txt

and Installation

Guides available on the CD shipped with your board(s).

1. If you haven’t already installed the hardware, turn off the power to your computer and open it to expose the PCI Express card edge (consult your system’s documentation for more information on this step).

2. Choose an available position, and carefully press the card into place. Re-assemble the computer.

3. After installing the BlueStorm/Express, turn on your system and the Found New Hardware

Wizard will appear.

Step 3- Found New Hardware Step 5 – Search for drivers

4. Insert the BlueStorm/Express CD into your drive. Choose what you want the wizard to do by selecting Install from a list or specific location (Advanced). Select Next.

5. Choose Select removable media (floppy, CD-ROM) and Include this location in the search and type D:\ Drivers\Win2K-XP, where D is the drive letter of your CD ROM. Now select Finish.

The Found New Hardware Wizard will repeat steps 3 through 5 to complete the installation of the

BlueStorm/Express serial ports. Please follow the on-screen instructions. Installation is complete when no more dialogue boxes appear.

28 Revision 0.11

Connect Tech BlueStorm/Express User Manual

Verify the presence of BlueStorm/Express serial ports in your system by going to Start – Control

Panel – System – Hardware – Device Manager – Multi-port serial adapters. You should see CTI X-

PORT PCI Express UART RS232/485 listed.

Port Settings

You can now access individual port settings such as baud rate, data bits, parity, stop bits and flow control by choosing the appropriate CTI PCI Express UART serial port under Ports in the Device

Manager. Clicking on Advanced while in Port Settings will access port settings for FIFO buffers,

Baud Rate Mapping, and RS-422/485 options (see the RS-422/485 Electrical Interface section for

more details.)

Revision 0.11 29

Connect Tech BlueStorm/Express User Manual

Advanced Port Settings

Use FIFO Buffers

For performance reasons, it is preferred that the FIFO buffers on the UART be used. When the

Use FIFO Buffers option is enabled, the UART will be more efficient at moving data. Other functions such as flow control will be managed by the UART when this option is enabled.

In some cases you may need to disable the FIFO buffers. This issue usually happens when the connected equipment cannot deal with data that is sent with minimal gaps between characters, or cases where the EscapeCommFunction (PortHandle, SETXOFF) function is used.

Receive and Transmit FIFO Settings

These sliders adjust the size of UART FIFO levels used by the CTI PCI Express UART serial ports. You obtain more buffering the further you move the slider to the right. This results in higher throughput, and lower load on the system. Note that high buffer levels can cause communication problems with some applications.

Usually the best setting is to have the receive buffer set at one notch blow the highest setting and the transmit buffer at the highest setting.

Software Settings for RS-422/485

RS-422/485 ports have the following options available:

Full Duplex

In this mode, TxD & RxD are active all the time. This mode is typically used in point-to-point situations much like RS-232. RTS and CTS can be used along with the data signals.

Half Duplex

In this mode the TxD line driver is only enabled when data is transmitted, and RxD is disabled when data is being transmitted. This mode is typically used in either point-to-point (2 wire) connections OR in multi-drop (2 wire) bussed connections. CTS and RTS are not usually used with this configuration.

Multi-Drop

In this mode the TxD line driver is only enabled when data is transmitted and RxD is enabled all the time. This mode is typically used in multi-drop (4 wire) connections. RTS and CTS are not usually used in this configuration.

Note: RS-485 Options are available if your BlueStorm/Express card is built or configured as RS-485, but does not mean the port is currently set this way. Check your card and ensure the jumpers are configured for RS-485 operation before changing the software setting.

30 Revision 0.11

Connect Tech BlueStorm/Express User Manual

Baud Rate Mapping

In some applications, high or unusual baud rates such as 230400 bps cannot be specified directly.

In such a case, we provide two baud rates (110 bps and 300 bps) which can be mapped to different values if necessary.

By default 300 baud is mapped to 230400 baud. In this case, an actual baud rate will be 230400 will be set when 300 baud is specified.

If baud rate mapping is not desired specify the same baud rate in the edit box beside each of the selections. For example 300 would be set to 300 and 110 would be set to 110.

Clock Frequency

The clock frequency used by the current CTI PCI Express UART is shown in the Clock

Frequency box.

COM Number

The driver supports the ability to change COM port names, which is also referred to as COM port mapping. Use this combo box to change the COM port number to be used for the current port.

For example specifying COM5 would set the COM name for this port to COM5.

Note: Ensure the COM name selected is not already in use or the port may not respond properly.

Revision 0.11 31

Connect Tech BlueStorm/Express User Manual

Specifications

Operating Environment

Storage temperature: -40

C to 105

C

Operating temperature: 0

C to 70

C (-40 to +85 Industrial Temp Versions)

Relative humidity:

Air movement:

5 to 95% non-condensing no requirement

PCI Express Interface

● One PCI Express x1 card edge

Communications

Baud Rates

RS-232: 50 bps – 921.6 Kbps

RS-422/485: 50 bps – 1.8432 Mbps

Custom baud rates are also available; please contact our Sales department for information. Some models (BEG005, BEG006, BDG001) can be set to any custom baud rate without any additional hardware changes.

32 Revision 0.11

Connect Tech BlueStorm/Express User Manual

UARTs

BlueStorm/Express (2 and 4 port models)

● 17D152 dual UARTs with 64 byte TxD/RxD FIFO buffers

BlueStorm/Express (8 and 16 port models)

● 17V258 octal UARTs with 64 byte TxD/RxD FIFO buffers

BlueStorm/Express Opto

● 17D152 dual UARTs with 64 byte TxD/RxD FIFO buffers

BlueStorm/Express Opto (1 kV)

● 17V258 octal UART with 64 byte TxD/RxD FIFO buffers

BlueStorm/Express Isolated

● 17V358 octal PCIe UART with 256 byte TxD/RxD FIFO buffers

Surge Suppression

BlueStorm/Express (2, 4, 8, and 16 port models)

● TransGuard

Transient Voltage Suppression, able to withstand multiple strikes on every signal of every port

Transient Energy dissipation 0.05 joules on every signal of every port

Transient peak current rating 15A on every signal of every port

EN61000-4-2/3/4 compatible

BlueStorm/Express Opto (1 kV) (Ports 1-4 only)

● TransGuard

Transient Voltage Suppression, able to withstand multiple strikes on every signal of every port

Transient Energy dissipation 0.05 joules on every signal of every port

Transient peak current rating 15A on every signal of every port

EN61000-4-2/3/4 compatible

Isolation Ratings

BlueStorm/Express Opto and BlueStorm/Express LP Opto

● 3kV peak to peak on every signal of every port

BlueStorm/Express Opto (1 kV)

● 1kV peak to peak on every signal of ports 5 thru 8. Ports 1 through 4 are non-isolated

BlueStorm/Express Isolated

3kV DC peak on Board

2kV DC peak Port to Port with cable

Dimensions

BlueStorm/Express (2 and 4 port models)

Length: 10.86 cm, 4.275 inches

Height: 10.92 cm, 4.300 inches

BlueStorm/Express (8 and 16 port models)

Length: 14.699 cm, 5.775 inches

Height: 11.1125 cm, 4.375 inches

Revision 0.11 33

Connect Tech BlueStorm/Express User Manual

BlueStorm/Express Opto (2 and 4 port as well as 8 port(1 kV) models)

Length: 14.699 cm, 5.775 inches

Height: 11.049 cm, 4.350 inches

BlueStorm/Express LP Opto

Length: 15.7 cm, 6.2 inches

Height: 6.9 cm, 2.7 inches

BlueStorm/Express Isolated

Length: 14.699 cm, 5.775 inches

Height: 11.049 cm, 4.350 inches

● 3D Model Available by request ([email protected])

Certification

Connect Tech Inc. declares that the product(s) covered by the contents of this manual have been tested and found compliant with the below listed standards as required by the Electromagnetic

Compatibility (EMC) Directive for General Immunity Compliance, EN 50 0082.1:1997

EN 55022 Conducted and Radiated emissions

CISPR 22 Class A

EN 55024 Immunity to Disturbances

EN 61000-4-2

EN 61000-4-3

EN 61000-4-4

EN 61000-4-6

The above satisfy the requirements of:

USA: FCC – CFR47, Part 15, part 2

Canada:

Europe:

Japan:

ICES-003

EMC Directive

VCCI

Industry Industrie

Canada Canada

Australia/New Zealand: AS/NZS

The above agency conformances were met by independent laboratory testing of Connect Tech Inc. product(s) with shielded cables, with metal hoods, attached to either the terminating connectors or cable assemblies supplied with the product(s). Failure to follow good EMC/EMI compliant cabling practices may produce more emissions or less immunity than were obtained in laboratory measurements.

Operation of this equipment in a residential area may cause unacceptable interference to radio and

TV reception, requiring the user to take whatever steps necessary to correct the interference.

34 Revision 0.11