ER34615M: D Size Spiral Cell Technical Datasheet
ER34615M: D Size Spiral Cell
Technical Datasheet
Technical Specifications
Features
• High and flat operating voltage
• High power and higher energy for the
whole battery life
• High drain capability
• Higher power applications
• Low self-discharge rate (<1% per year at
20°C)
• Battery life higher than 10 years,
depending on the application
• Hermetic glass-to-metal sealing
• Avoid leakage, key for higher than 10
year battery life
• Non-flammable electrolyte
• Safer operation in case of abuse
• PTC device
• Safe operation in the event of a
short circuit
Part No.
ER34615M
Cell Type
Primary, non-rechargeable
Chemistry
Lithium Thionyl Chloride
Voltage Range
2.0 to 3.7V
Nominal Voltage
3.6V
Nominal Capacity
14.5Ah @ 10mA to 2.0V @ 20°C
Max. Continuous Discharge Current
2000mA continuous
Max. Pulse Discharge Current
Up to 3000mA (life and temperature dependent)
Weight
107g
Operating Temperature
-55°C to 85°C
Storage Temperature
-55°C to 85°C (max 30°C for a >5 years life)
Exterior/Housing
Stainless steel container
Terminals/Connector
Radial tabs / radial pins / axial leads / flying leads
Safety
AL-MSDS/RD-002
Material Safety Datasheet - MSDS041
Safety Guide UBM-5112
Transportation
Class 9 - A complete description of transportation
regulations, lithium weights and transportation
classifications is available on the Ultralife
website.
Quality Assurance
Ultralife manufacturing facilities are ISO
9001:2008 and ISO 14001:2004 registered.
Its products are listed under the Component
Recognition Program of Underwriters
Laboratories (UL) and have passed UN
transportation testing, which is required for
international transportation of all lithium batteries.
Typical Applications
•
•
•
•
Military and other radio applications
Smart meters
Alarm and security systems
Beacons and emergency location
transmitters
• GPS
• LED lighting applications
ER34615M
Newark, New York | 315-332-7100 | Fax: 315-331-7800
©2013 Ultralife Corporation • www.ultralifecorp.com • All information is subject to change without notice.
The information contained herein is for reference only and does not constitute a warranty of performance. • 19 AUG 13 UBM-0068 Rev: -
Dimensions
Typical Performance Graphs
Constant Load Discharge Voltage versus Discharge Time at 25°C
ER34615M
3.8
3.8
3.7
3.6
3.6
Discharge Voltage (V)
3.4
3.2
3.0
1.8Ω-1800mA-9Ah-5h
2.8
4.5Ω-730mA-10Ah-13.7h
2.6
33Ω-103mA-12.6Ah-122h
2.4
2.2
3.5
3.4
1mA
3.3
5mA
3.2
30mA
300mA
3.1
350Ω-10mA-14.5Ah-1450h
3.0
3.6kΩ-1mA-13.5Ah-13500h
2.9
High and flat voltage at high and low drain
Temperature (°C)
High voltage at high drain even at -30°C
ER34615M
Newark, New York | 315-332-7100 | Fax: 315-331-7800
©2013 Ultralife Corporation • www.ultralifecorp.com • All information is subject to change without notice.
The information contained herein is for reference only and does not constitute a warranty of performance. • 19 AUG 13 UBM-0068 Rev: -
80
60
40
20
0
-20
-40
10000
1000
100
10
Discharge Time (h)
-60
2.8
2.0
1
Discharge Voltage (V)
Voltage versus Temperature at Different Discharge Currents
ER34615M
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project