O W N E R ' S M A N U A L

M A N U A L

C & H A IR C O N D I T I O N E R S

Air Conditioner

FLOOR-TO-CEILING SERIES

MODELS:

indoor unit / outdoor unit

GTH18K3BI / GUHN24NK3AO

GTH24K3BI / GUHN24NK3AO

GTH36K3BI / GUHN36NM3AO

GTH48K3BI / GUHN48NM3AO

Thanks for your selection of our Air-Conditioning Unit. Before use, please read this instruction manual carefully and keep it properly to ensure correct use of this machine.

Safety Considerations

Please read this manual carefully before use and operate correctly as instructed in the manual.

1 You are specially warned to note the two symbols below.:

WARNING!

A symbol indicating that improper operation might cause human death or severe injuries.

A symbol indicating that improper operation might cause human injury or property damage.

WARNING!

● This unit shall be used in the houses, offices, restaurants, residences or similar places.

● Please seek an authorized repair station for installation work. Improper installation might cause water leakage, electric shock or fire.

● Please install at a place strong enough to support the weight of air conditioner unit. If not, the air conditioner unit might fall down and cause human injury or death.

● To ensure proper drainage, the drainage pipe shall be correctly installed according to installation instructions.

Take proper measures for heat preservation to prevent condensing. Improper installation of pipes might cause leakage and wet the articles in the room.

● Do not use or store flammable, explosive, poisonous or other dangerous substances beside the air conditioner.

● In case of trouble (e.g. burnt smell), please immediately cut off the main power of air conditioner unit.

● Keep air flow to avoid shortage of oxygen in the room.

● Never insert your finger or any objects into air outlet and inlet grill.

● Never plug or unplug the power cable directly to start or stop the air-conditioning unit.

● Please take constant care to check if the mounting rack is damaged after long use.

● Never modify the air conditioner. Please contact the dealer or professional installation workers for repair or relocation of the air conditioner.

● The appliance shall not be installed in the laundry.

WARNING!:

● The installation, cleaning and maintenance work must be done by a qualified person. Do not do such work by yourself.

● Before installation, please check the power supply for compliance with the ratings on nameplate. Check the power safety as well.

● Before use, please check and confirm if the cables, drainage pipes and pipelines are correctly connected, hence to eliminate the risk of water leakage, refrigerant leakage, electric shock or fire.

● Main power must be securely earthed to ensure effective grounding of air conditioner unit and avoid the risk of electric shock. Please do not connect the earthling cable to coal gas pipe, water pipe, lightning rod or telephone line.

● Once started, the air conditioner shall not be stopped at least after 5 minutes or longer; otherwise the oil return to compressor may be affected.

● Do not let the child to operate the air conditioner unit.

● Do not operate the air conditioner unit with wet hands.

● Please disconnect the main power before cleaning the air conditioner or replacing the air filter.(Operating by professional)

● Please disconnect the main power if to put the air conditioner unit out of use for a long period.

● Please do not expose the air conditioner unit directly under corrosive environment with water or moisture.

● Please do not foot on or place any goods on air conditioner unit.

● After electrical installation, the air conditioner unit shall be energized for electrical leakage test.

● If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard .

● An all-pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring.

● The appliance shall be installed in accordance with national wiring regulations.

● The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the per tube.

Wire controller (standard fitting)

SWING

SWING

TIMER

Composition of wire controller

1

Timing display

2

Fan speed display (Auto, High speed, Medium speed, Low speed)

3 Defros ting st atus display

4 Ener gy saving st atus display

5

6

Se t temperatur e display

Ambient temperatur e display

9

10

11

12

Failure st atus display

Sleep st atus display

Mode key

Se t temperatur e incr ease key

13 Se t temperatur e decr ease key

14 Fan speed key (fresh air setting)

15 Sleep key (outdoor environment temperatur e check)

7

8

Fr esh air st atus display (not supplied)

Mode (cooling, dehumidifying,fan, heating, auto)

16 Timing key

17 ON/OFF key

• Never install the wire controller in a place where is water leakage.

• Avoid bumping, throwing, tossing or frequently opening the wire controller.

Operating instructions of wire controller

Turning ON/OFF unit

Press the ON/OFF key, then the unit shall start up. Press the ON/OFF key again, then the unit shall shut off.

SWING

TIMER

Fan control (the figures show the relevant display areas)

If the fan control key is pressed consecutively, the fan speed shall changes as per the following sequence :

Low speed Medium speed High speed Auto

SWING

TIMER

In the dehumidifying mode: The fan speed shall be automatically set as low.

Temperature setting

SWING

TIMER

Press the temperature setting key( ) to increase the set temperature; press the temperature setting key ( ) to decrease the set temperature (when pressing the keys once, the temperature shall increase or decrease by 1 °C). NOTE: key lock function: when the ( ) and( ) key are pressed simultaneously for 5 second, the se t temperature indicating are a shall display “EE” and all keys response shall be shut off; press the two keys simultaneously for 5 second again, the key lock function shall be released. When the wire controller is locked by remote monitor or centralized controller, the keys of the wire controller and the signal of the remote controller are all locked and invalidated, and then the se t temperature indicating are a shall display “CC”. Range of temperature setting under various modes:

Heating: 16 °C~ 30 °C Cooling: 16 °C~ 30 °C

: 6 °C~ 30 °C

Fan: No temperature setting function.

Swing function setting

SWING

SWING

TIMER

Sleep function setting

SWING

TIMER

Press Swing button then the swing mode will be operated by the air conditioner.

Repress Swing button once to stop swing mode.

Note: There is no swing mode for duct type indoor unit

When under the cooling or dehumidifying mode, after receiving the SLEEP order for 1 hour, the previous set temp. Set will be risen for 1

°C

, and another 1

°C

will be risen after 2 hours that means that the temperature been risen 2

°C

within 2 hours. Then the unit will run according to this set temp.

When under the heating mode, after receiving the SLEEP order for 1 hour, the previous set temp. Set will be lower for 1

°C

, and another 1

°C

will be lower after 2 hours that means that the temperature been lowered 2

°C

within 2 hours. Then the unit will run according to this set temp.

There is no SLEEP mode under fan mode.

Note: The wired remote controller has no SLEEP mode button; if SLEEP mode is needed to be set, complete the procedure by wireless remote controller.

Operating Mode Setting

SWING

TIMER

This key is pressed consecutively, the operating mode shall change as per the following sequence:

Cooling Dehumidifying Fan Heating Auto

When the unit operates under “Cooling” mode, “COOL” shall be displayed. Now the set temperature must be lower than the ambient temperature. Now if the set temperature is higher than the ambient temperature, the unit shall not produce cooling effect but shall only operate under. Fan mode. When the unit operates under “Dehumidifying” mode, “DRY” shall be displayed. Now the interior fan shall operate in the manner of low speed air supply within a certain range of temperatures. The dehumidifying effect of this mode is better than that of the

Cooling mode and saves more energy.

When the unit operates under “Heating” mode, “HEAT” shall be displayed. Now the set temperature must be higher than the ambient temperature; Now if the set temperature is lower than the ambient temperature, the heating function shall not be started.

When the unit operates under “Fan” mode, “FAN” shall be displayed. When the unit operates under “Auto” mode, “AUTO” shall be displayed and the unit shall adjust its operating mode automatically according to the ambient temperature.

When the unit operates under Heating mode and the outdoor temperature is low and the humidity is high, frost shall produce at the outdoor unit. Now the heating efficiency shall be decreased. When frosting hap- pens, the controller shall automatically start to defrost, and “DEFROST” shall be displayed.

Note: Cooling only type unit does not have heating mode and when energy saving is set the Auto mode shall be invalidated.

Timer Setting

SWING

TIMER

Energy Saving Setting

SWING

TIMER

When the unit is shut off, timing start can be set; After the unit is started up, timing shutoff can be set. After the "TIMER" key is pressed, the unit enters the timing set status and the word "TIMER" flashes on the display. Now user can press ( ) or( ) key to increase or decrease the set time. Press the "TIMER" key again and then the timing shall go into effect. Now the unit starts to count the time passed. When the unit is under timing status, you can cannel timing set by pressing the “TIMER” key. The range of set time is between 0.5 to 24 hours.

When the unit is shut off, press the “FAN” key and the ( ) simultaneously for 5 consecutive seconds to activate the energy saving setting menu. Now “SAVE” and

“COOL” are displayed (In case it is the first time to set energy saving, the initial value shall be displayed: 26. The lower limit of temperature shall be displayed on the set temperature and the temperature value under setting shall flash. Set the lower limit of cooling temperature using the ( ) key or the ( ) key (the lower limit temperature can be selected from the range between 16-30). Press the “ON/OFF” key to confirm the setting; Also use the ( ) key or the ( ) key to set the upper limit of temperature and the temperature value shall flash on the ambient temperature area (OUT ENV area) (the upper limit temperature can be selected from the range between 16-30). Press the “ON/OFF” key to confirm the setting. Please pay attention that the upper limit temperature must be higher than the set lower limit temperature; Otherwise the system shall regard the higher temperature as the upper limit temperature and the lower one as the lower limit temperature. Press the “MODE” key to complete the energy saving setting for the modes of cooling and dehumidifying and turn to the energy saving setting for the heating mode

(Cooling only unit does not have this function). Now the LCD displays “SAVE” and

“HEAT”. After setting is completed, press the “FAN” key and the ( ) key simultaneously for 5 consecutive seconds to exit the setting of energy saving. After the energy saving setting interface is activated, the system shall exit the interface if there is no any operation within 20 seconds af ter the last key input, and the normal shutoff status interface shall be displayed. After the above settings are completed, the system shall display “SAVE”. Now the set temperature shall not exceed the temperature range of the energy saving setting before. For example, the lower cooling limit is set as 23°C and the upper cooling limit is set as 27°C for the energy saving temperature setting in left so the cooling temperature can only be selected from the range of 23 °C to 27°C by using the remote controller or the wire controller later. If the upper limit temperature is the same as the lower limit temperature, the system can only operate at such temperature under relevant modes. Remove of energy saving setting: To remove the energy saving setting after it takes into effect, you can press the “FAN” and the ( ) key simultaneously for 5 consecutive seconds when the unit is shut off. But the value set before will not be cleared but as the initial set temperature for the next energy saving setting.

After the unit is disconnected to power supply, the energy saving setting shall be stored. The setting still functions when the unit is connected to power supply again. If the energy saving mode is set, the sleep mode and the auto mode shall be

Display outdoor temperature

SWING

TIMER

Power-fail Memory Function Setting

SWING

TIMER

Debug Function Setting

Under normal conditions, the “OUT ENV” column shall only display the indoor temperature. Press the “SLEEP” key for 5 consecutive seconds when the unit is shut off or start up, the LCD shall display “OUT ENV”. After the outdoor temperature is displayed for 10 seconds, the system shall return to the display interface of indoor temperature. Note: If not equipped with an outdoor ambient sensor, the unit shall not have this function.

Press and hold the “MODE” key for 10 seconds when the unit is shut off to switch set values so as to decide if the unit operating status or shutoff status shall be memorized after a power fail. If the set temperature area displays 01, it means the unit operating status or shutoff status shall be memorized after a power fail; 02 means the operating status or shutoff status shall not be memorized. Press the

“ON/OFF” key to store the set value and exit the setting.

When the unit is shut off, press the “FAN” key and the “SWING” key

Simultaneously to activate the debug menu. Now the LCD displays “DEBUG”.

Press the “MODE” key to select setting item and use the ( ) key or the ( ) key to set actual value.

Setting of Ambient Temp. Sensor Under the debug mode , press the “MODE” key so as to display “01” On the set temperature area (at the left of “DEBUG”). The

OUT ENV area (at the right of “DEBUG”) displays setting status. Now use the

( ) key or the ( ) key to select from the following two settings:

The indoor room temperature is measured at the air intake(Now the OUT ENV area displays 01).

The indoor room temperature is measured at the wire controller (Now the OUT

ENV area displays 02).

The indoor room temperature is measured at the wire controller when the mode is

'heating' or 'auto'. At other modes, it is measured at the air intake (Now the OUT

ENV area displays 03). The default is 03.

Failure Display

SWING

When there is failure in the unit operation, “ERROR” will flash on the LCD of the wire controller and the code of failure will also be displayed. When there are multiple failures at the same time, the codes of failures will be displayed one after one on the wire controller. The first digit of the code denotes the system number. When there is only one system, it will display the system number 1. The last two digits denote the detailed failure code. For example, the code in left means low pressure protection of compressor.

Fault code

E0

E1

E2

E3

Pump Failure

Compressor Low Pressure

Protection

The Codes of Failure Definitions are as Follows:

Fault Fault code

F0

Compressor High Pressure

Protection

Indoor Frost-Proof Protection

F1

F2

F3

Fault

Failure of Indoor Room Sensor at Air

Intake

Failure of Evaporator Temp. Sensor

Failure of Condenser Temp. Sensor

Failure of Outdoor Ambient Sensor

E4

E5

Compressor Exhaust High

Temperature Protection

Compressor Overheat

F4

F5

Failure of Exhaust Temp. Sensor

Failure of Indoor Room Sensor at Wire

Controller

E6

Communications Failure

E8

E9

Indoor Fan Protection

Full Water Protection

E5 Material Malfunction Will Be Showed By The Indicator Light On The Mother Board Of Outside Unit

• 7DP - Seven days programmer (Accessory not supplied)

Centralized Control and Week Timer

Functions: The centralized control- ler and the weekly timer are integra- ted in the same wire controller. The system has both the centralized control and the week timing functions. Up to

16 sets of units can be control- led simultaneously by the centralized controller (weekly timer). The weekly

Unit Function

timer has the function of invalidating lower unit. The weekly timing function is able to realized four timing ON/OFF periods for any unit every day, so as to achieve fully automatic operation.

This WEEKLY TIMER adopts 485 mode to communicate with manual control of every duct type unit, and it can control up to 16 units. Adopting 2-core twisted-pair wire, the longest communication distance of this TIMER is 1200m. After connected to power, the

WEEKLY TIMER can display all connected units (sequence of unit is determined by code switch of manual control of every duct type unit). On and off of every duct type unit can be done through the Timer On / Off of this

WEEKLY TIMER, and the button shield operation of manual control can be done through shield setting on WEEKLY

TIMER. Mode selection and temperature adjustment and other operations are done through the manual control at every unit.

Arrangement

1

Unit dispaly

2

Single/group display

3

Timer week display

4

Timer display

5

Timer state display

6

Timer time period display

7

Timer ON/OFF time display

8

Unit on display

9 Unit off display

10 Clock display

11

Confirm button

12 Increase button

13

Decrease button

14

Cacel/delete button

15 Single/group button

16 Timer/time button

17

ON/OFF button

Note:

1.

For upper unit checks 16 lower units consecutively, there will be no more than 16 seconds delay when setting works till unit responds.

2.

Please let us know your requirement before your placing the order, for this WEEKLY TIMER will only be prepared when customer orders (communication joint with WEEKLY TIMER on manual control had been prepared).

1. Press or to select the unit that needed to be control. It is available to control several units by

Group Control (1~16), or control single unit by Single Control.

2.

When selected a certain or several units by Single Control or Group Control, Timer setting and On/off setting can be set. Timer setting can set 4 on/off times in a day in one week; and on/off setting can be done by pressing on/off button.

3. Connection between WEEKLY TIMER and manual control is shown as following:

Week timer Manual control Manual control

LCD LCD

16 units in max

LCD

Power supply

Telephone wire box Telephone wire box

Twisted wire with crystal joint

Telephone wire box

Longest distance 1200 m

On Off

Power

Corresponding relation between code switch and sequence of unit (NOTE: put- ting code switch to ON means 0)

Wire controller (with week timer functions)

WARNING!

Never install the wired controller where there is water leakage.

Never knock, throw or frequently open the wired controller.

Fig.1

Each part of wired controller

1

Timing Display

2

Ambient Temperature Display

3

Energy Saving Status Display

4

Set Temperature Display

11

Swing Status Display

12

Timer interval Display

13

Mode Button

14

Set Temperature Increase Button

5

6

Week Display

Speed, Medium Speed, Low Speed)

7

Defrosting Status Display

8

Fan Speed Display (Auto, High

Fresh Air Status Display

15

Set Temperature Decrease Button

16

Fan Speed Button

17

Swing Button

18

Timing Button

9

Mode (Cooling, Dehumidifying, Fan,

Heating, Auto)

10

Malfunction Display

19

ON/OFF Button

1) ON/OFF

Fig.2

Press the

ON/OFF

” button, the unit will start running.

Press the

ON/OFF

” button again, the unit will stop running.

2)

Fan Control

(Fig.3 is about display region and the same as following figures.)

When press FAN button once, the fan speed will be changed as follow:

In DRY mode: the fan speed will be set at low automatically.

3) Temperature Setting (Fig.4)

Press the setting temperature button:

For temperature increase

For temperature decrease

Press this button once, the temperature will be increased or decreased by 1.

Note:

Press

▲+ ▼button for 5 seconds, “EE” will appear where SET TEMP is displayed and all buttons are shielded. Press

▲+▼button again for 5 seconds to cancel locked function.

If long-distance monitoring controller or central controller shield displayer, all buttons and signals from remote controller will be shielded too, and CC will be displayed where SET TEMP is displayed.

Fig.2

Fig.

Fig.

3

4

Setting temperature range under each mode:

HEAT

-------- 16℃~30℃

COOL

-------- 16℃~30℃

DRY

-------- 16℃~30℃

FAN -------- can not be set

Auto mode is divides into new auto mode and old auto mode.

NEW AUTO MODE --------------16

℃~

30

OLD AUTO MODE ---------- can not be set

4) Swing Setting (Fig.5)

Press SWING button, SWING will be displayed on the

LCD, in which case, the unit is under swing status.

Press this button again, the words will disappear and the unit stops swinging.

Note: Sleep function can be set by remote controller.

5) Running Mode Setting (Fig.6)

Every press of mode button, the operation mode will change as follow:

COOL

DRY

FAN

HEAT

AUTO

In cool mode, COOL will light, in which case, setting temperature should be set to be lower than present ambient temperature; If not, the unit will not operate in cool mode and only the fan is active.

In dry mode, DRY will light .Indoor fan will run at low speed in certain temp. range. Dry efficiency as well as energy saving efficiency in this mode is much better than that in cool mode

In heat mode, HEAT will light. The setting temperature should be set to be higher than present ambient temperature; if not, the unit can not operate in heat mode.

In fan mode, FAN will light.

In auto mode, AUTO will light and the unit will run at the mode automatically adjusted according to ambient temp.

In heating mode, if outdoor temp is low with high humidity,

Fig.5

Fig. 6

the outdoor unit will be frosted resulting in low efficiency of heating, in which case, the controller will automatically start to defrost with DEFROST displayed.

Note: No heating for cooling-only unit and auto mode will be shielded after setting energy saving.

6)

Timer Setting (Fig.7, 8, 9)

Timer function in this wired controller connected with weekly timer is invalid and wired controller will be controlled by weekly timer.

Either in ON status or OFF status of the unit press

TIMER button into timing setting, and then press

▲ or

▼button to set timing(Fig.7),set time(Fig.8) and timing delete

(Fig.9). At last, press TIMER to set it.

Fig.7

Fig.8

Fig.9

In timing setting mode, press MODE button to select any desired setting object: Week (1-7), timer interval

(1-4), timing (Timer on or Timer off time), min. part or hour part of time, and then press

▲ or ▼ button to adjust this object, which is fixed by pressing TIMER button or can be canceled by pressing Timer again.

During fixing setting there must be blinking characters.

During canceling setting, if there are also blinking characters, setting can be continuous till quit It by pressing ON/OFF button; meanwhile, timing data are memorized. (Fig.10, 11)

In time setting mode press MODE button to select any desired setting object: Week (1-7), min. part (0-59) or hour part (0-23), and then press

▲ or ▼ button to adjust this object, which is fixed by pressing TIMER button or can be canceled by pressing Timer again.

During fixing setting there must be blinking characters. During canceling setting, if there are also blinking characters, setting can be continuous till quit

It by pressing ON/OFF button.(Fig.12)

Fig.10

Fig.11

Fig.12

In deleting timing status, press

▲ or ▼ button to select one day of a week, and then press TIMER button to confirm, in which case,

”dd” is displayed .The day also can be canceled by pressing

TIMER butto n without “dd” displayed. At last, press

ON/OFF button to quit the setting after finish.(Fig.13)

7) Outdoor Ambient Temp Display ( Fig.14)

In normal condition, only indoor ambient temp is displayed wher e “ENVIROMENT” is displayed. At on or off status of the unit, if press SWING button for 5 seconds, outdoor ambient temp (OUT ENV) will be displayed.

If outdoor temp is tested to be above zero, there will be no display where setting temp is displayed and outdoor ambient temp tested by inner system will be displayed where ambient temp is displayed.

If outdoor temp is tested to be below zero,

” will be displayed where set temp is displayed and absolute value of outdoor ambient temp tested by inner system will be displayed where ambient temp is displayed.

After 10 second display, the system will return to display interface of indoor ambient temp.

Note:

This unit function is invalid without connecting with outdoor ambient temp sensor.

8) Energy Saving Setting (Fig.15)

Press FAN+

▼ for 5 seconds into energy saving menu, in which case,

SAVE and COOL is displayed (If it

’s the first time for setting, initial value 26

℃ will be displayed.), lower-limit temp is displayed where set temp is displayed and set temp during setting is displayed and

Fig.13

Fig.14

Fig.15

blinking. Press

▲ and ▼ to set lower-limit cooling temp (setting range is16

30) and then press ON/OFF to fix .Press

▲ and ▼ to set upper-limit cooling temp, which will be displayed where ambient temp is displayed (setting range is 16-30), and then press ON/OFF to fix.

Note:

Upper- limit temp can not be set to be lower than lower- limit temp, or else the higher temp will be defaulted to be upper limit and the lower one to be lower- limit. Press MODE button to set energy saving in cooling or dry mode and then switch to energy saving setting in heating mode, in which case,

SAVE and HEAT will be displayed, which is quitted by pressing FAN and

▼ for 5 seconds. If there is no operation after the energy saving interface appears in 20s when the system responds last press of one button, the system will trip off the menu and display normal interface of unit off.

SAVE will be displayed in LCD at next startup of the unit if above setting has been finished. Either by pressing buttons of the displayer or remote controller, the setting temp can never be set to be higher than temp range set under energy saving mode before. For example, lower-limit cooling temp under energy saving mode is 23 and upper limit is 28

,so the user can only set cooling temperature in the range of 23-28

.

If the same limit temperature is set, the unit will only run under corresponding mode at this setting temp.

Press Fan+

▼ simultaneously for 5s to quit this function if it has been effective, but former setting value can not be cleared, which will be as the original value of next setting.

If the power is off, energy saving setting will be memorized, which continues effectively after the power is on next time.

If energy-saving mode and sleeping mode is setting, auto mode will be shielded.

9) Power

–off Memory Setting (Fig.16)

Press mode button continuously for 10s and select if memorize startup and stop status of the unit or not at unit.01 displayed in the region of displaying setting temp indicates memorizing start and stop status of the unit after power off .02, quit by pressing ON/OFF button ,indicates not memorizing. If after the interface of memorizing startup and stop status of the unit appears, there is no operation in 20s when the system responds the last press of one button, the system will trip off the menu and display normal stop interface, but it also memorizes present information.

10) Malfunction Display (Fig.17)

If malfunction happens during operating of the unit, ERROR will blink with error code displayed. For example, the right figure indicates compressor low-pressure protection.

Fig.16

E6

E8

E9

F0

Codes Malfunction

E0 Water pump malfunction

E1

E2

E3

E4

E5

Compressor high-pressure protection

Indoor anti-freezing protection

Compressor low-pressure protection

Compressor overload protection

Compressor high-temp. exhaust protection

Communication malfunction

Indoor fan protection

Water-full protection

Air inlet indoor ambient temp. sensor malfunction

F1

F2

F3

F4

F5

EH

Evaporator temp. sensor malfunction

Condenser temp. sensor malfunction

Outdoor ambient temp. sensor malfunction

Exhaust ambient temp. sensor malfunction

Ambient temp. sensor malfunction in displayer

Auxiliary electric heat malfunction

Note!

Fig.17

Fig.17

If EH malfunction happens, please power the unit off immediately and ask professionals for help.

CHECKING BEFORE CONTACT THE SERVICE MAN

OPERATION INSTRUCTIONS

OPERATION INSTRUCTIONS

PROBLEM

S

Check if breaker switch is still on

Indoor Unit Installation

INSTALLATION DIMENSIONS OF THE INDOOR UNIT

INSTALLATION INSTRUCTIONS

When installing the indoor unit, you can refer the paper pattern for installation, and make sure that the drainage side must be 10mm lower than the other side in order to drain the condensation water fluently.

D

E

A

B

C

Model

GTH18K3BI

GTH24K3BI

GTH36K3BI

GTH48K3BI

A

836

1300

1590

B

238

188

238

C

745

1202

1491

D

695

600

695

Unit mm

E

260

260

260

Indoor Unit Installation

SELECTION OF INSTALLATION LOCATION.

Such a place where cool air can be distributed through out the room.

Such a place where is condensation water is easily drained out.

Such a place that can handle the weight of indoor unit.

Such a place which has easy access for maintenance.

Such a place where is permitting easy connection with the outdoor unit.

Such a place where is 1m or more away from other electric appliances such as television, audio device, etc.

Avoid a location where there is heat source, high humidity or inflammable gas.

Do not use the unit in the immediate surroundings of a laundry, a bath, a shower or a swimming pool.

Be sure that the installation conforms to the installation dimension diagram.

The space around the unit is adequate for ventilation (Refer to Fig.23)

THERE ARE 2 STYLES OF INSTALLATION.

CEILING TYPE

FLOOR TYPE

Each type is similar to the other as follows;

Determine the mounting position on ceiling or wall by using paper pattern to indicate indoor.

Mark the pattern and pull out the paper pattern.

Remove the return grill, the side panel and the hanger bracket from the indoor unit as per procedure bellow.

Press the fixing knob of the return grilles, the grilles will be opened wider and then pull it out from the indoor.

Remove the side panel fixing screw and pull to the front direction (arrow direction) to remove.

(Refer to Fig.24)

Loosen two hanger bracket setting bolts (M8) on each side for less than 10mm. Remove two hanger bracket fixing bolts (M6) on the rear side.

Detach the hanger bracket by pulling it backward

(Refer to Fig.26)

INSTALLATION INSTRUCTIONS

CAUTION FOR INSTALLATION WHERE

AIR CONDITIONER TROUBLE IS LIKELY

TO OCCUR.

Where there is too much of oil.

Where it is acid base area.

Where there is irregular electrical supply.

INSTALLATION

PAPER PLANK

Fig.22

150cm or more

60cm or more

100cm or more

Fig.23

30cm or more

Side panel fixing screw(M4)

Fig.24

60cm or more

Indoor Unit Installation

Set the suspension bolt.(Use W3/8 or M10 size suspension bolts)

Adjust the distance from the unit to the ceiling slab beforehand (Refer to Fig.25)

INSTALLATION INSTRUCTIONS

27

28

26

26

29

30

40mm or less

Fig.25

Fig.25

Fig.2

Fig.2

Fig.27

Fig.29

Fig.3

CAUTION

Outdoor Unit Installation

Fig.31

Fig.32

INSTALLATION INSTRUCTIONS

Outdoor Unit Installation

INS TALLATION INS T R UC T IONS

Electric wiring connection

GUHN18NK3AO

GUHN24NK3AO

GUHN36NK3AO

GUHN48NM3AO or

C A U T I O N

Wrong wiring ma y c a us e fire of electric s hock.

D o not pull the wire when fixing it with wire clamp and clasp.

Do not let the wire too loose

All the electrical work must be done by qualified personnel according to the local rules and this instruction.

T he rated voltage and the exclusive circuit must be used.

Lea ka ge circuit-brea ker must be installed.

P lea s e us e specified fuse.

If the power supply cord of the unit is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.

An all-pole disconnection air switch which have a contact separation of at least 3mm in all pole is needed.

Profile Dimensions of Outdoor Unit

Profile Dimensions of Outdoor Unit

Fig. 30

Uni t mm

Model

Item

A

B

C

D

E

GUHN18NK3AO

848

320

540

540

286

GUHN24NK3AO

1018

412

700

572

300

Unit Installation Instructions

Precautions on Installation of Outdoor Unit

Fig.

GUHN36NM3AO

1018

412

840

572

378

GUHN48NM3AO

950

412

1250

572

378

To ensure the unit in proper function, selection of installation location must be in accordance with following principles:

(1) Outdoor unit shall be installed so that the air discharged by outdoor unit will not return and that sufficient space for repair shall be provided around the machine.

The installation site must have good ventilation, so that the outdoor unit can take in and exhaust enough. Ensure that there is no obstacle for the air intake and exhaust of the outdoor unit. If there is any obstacle blocking the air intake or exhaust, remove it.

Place of installation shall be strong enough to support the weight of outdoor unit, and it shall be able to insulate noise and prevent vibration. Ensure that the wind and noise from the unit will not affect your neighbors.

Avoid direct sunshine over the unit. It is better to set up a sun shield as the protection.

Place of installation must be able to drain the rainwater and defrosting water.

Place of installation must ensure the machine will not be buried under snow or subject to the influence of rubbish or oil fog.

The installation site must be at a place where the air exhaust outlet does not face strong wind.

Schematic Diagram of Unit Line Connection

INSTALLATION INSTRUCTIONS

Electric wiring connection

The section area of cables selected by users must not be smaller than the specifications show diagram. The signal wire between indoor and outdoor unit shall be installed in the shielded bushing, and the unshielded twisted pair cable (UTP) shall be used, the cross sectional area of the cables must be 0.75 mm

2

.

GUHN18NK3AO GTH18K3BI

GUHN24NK3AO GTH24K3BI

Outdoor Unit

Intdoor Unit 1 Power cord 3 mm

2

2 Power cord 3 1.5mm

2

(H07RN-F)

(H05VV-F)

3 Communication Cords (UTP)

GUHN36NM3AO GTH36K3BI

Outdoor Unit

Intdoor Unit

1

Power cord 3×6mm

2

(H07RN-F)

2 Power cord 3×1.5mm

2

(H05VV-F)

3

Communication Cords (UTP)

GUHN48NM3AO GTH48K3BI

1

Power cord 5×4mm

2

2

Power cord 3×1.5mm

2

(H07RN-F)

(H05VV-F)

3

Communication Cords (UTP)

Schematic Diagram of Unit Line Connection

GUHN18NK3AO

GUHN24NK3AO

GUHN36NM3AO

GUHN48NM3AO

All the indoor units

INSTALLATION INSTRUCTIONS

Position and Method of Installing Wire Controller

Position and Method of Installing Wire Controller

INSTALLATION INSTRUCTIONS

1. One end of the control wire of the manual controller is connected with main board of electric box of indoor unit inside, it should be tightened by wire clamp, the other end should be connected with the manual controller (installation sketch map as shown in below). The control wire be used for the indoor unit and manual controller, which is the special communication wire, the length is 8 meters, the material be adopted for the control wire should be metallic substance. The manual controller could not be disassembled and the communication wire be used for the manual controller should not be changed by users optionally, the installation and maintenance should be carried out by the professional personnel.

2. First select an installation position. According to the size of the communication line of the wire controller, leave a recess or a embedded wire hole to bury the communication line.

3.

If the communication line between the wire controller (85 x 85 x 16) and the indoor unit is surface-mounted, use 1# metallic pipe and make matching recess in the wall (refer to Figure 41); If concealed installation is adopted, 1# metallic pipe can be used (Refer to Figure 42).

4.

No matter if surface mounting or concealed mounting is selected, it is required to drill 2 holes (in the same level) which distance shall be the same as the distance (60mm) of installation holes in the bottom plate of the wire controller. Then insert a wood plug into each hole. Fix the bottom plate of the wire controller to the wall by using the two holes. Plug the communication line onto the control panel.

Lastly install the panel of the wire controller.

Caution:

During the installation of the bottom plate of the wire controller, pay attention to the direction of the bottom plate. The plate

’s side with two notches must be at the lower position, and otherwise the panel of the wire controller cannot be correctly installed.

Position and Method of Installing Wire Controller

Electric box cover

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Sketch map for indoor unit communication wire

Wire clamp

Control wire

Cable-cross loop

Communication wire

metallic Pipe metallic Pipe

1 2 3 4

Figure 43 Surface

Mounting of Cable

Figure 44 Concealed mounting of Cable

Figure 45 Schematic Diagram of Installation

No.

1

Name

Wall Surface

2

Bottom Plate of Wire Controller

3

Screw M4X10

4

Panel of Wire Controller

Caution:

1.

The communication distance between the main board and the wire controller is 8 meters.

2. The wire controller shall not be installed in a place where there is water drop or large amount of water vapor.

Position and Method of Installing Wire Controller

INSTALLATION INSTRUCTIONS

Caution:

Before installing the electrical equipment, please pay attention to the following matters which have been specially pointed out by our designers:

(1) Check to see if the power supply used conforms to the rated power supply specified on the nameplate.

(2) The capacity of the power supply must be large enough.

(3) The lines must be installed by professional personnel.

An electricity leakage protection switch and an air switch with gap between electrode heads larger than

3mm shall be installed in the fixed line.

1.

Connection of single wire

(1)

Use wire stripper to strip the insulation layer (25mm long) from the end of the single wire.

(2) Remove the screw at the terminal board of the air-conditioning unit.

(3) User pliers to bend the end of the single wire so that a loop matching the screw size is formed.

(4) Put the screw through the loop of the single wire and fix the loop at the terminal board.

2. Connection of multiple twisted wires

(1) Use wire stripper to strip the insulation layer (10mm long) from the end of the multiple twisted wires.

(2) Remove the screw at the terminal board of the air-conditioning unit.

(3)

Use crimping pliers to connect a terminal (matching the size of the screw) at the end of the multiple twisted wires.

(4)

Put the screw through the terminal of the multiple twisted wires and fix the terminal at the terminal board.

Warning:

If the power supply flexible line or the signal line of the equipment is damaged, only use special flexible line to replace it.

1.

Before connecting lines, read the voltages of the relevant parts on the nameplate. Then carry out line connection according to the schematic diagram.

2.

The air-conditioning unit shall have special power supply line which shall be equipped with electricity leakage switch and air switch, so as to deal with overload conditions.

3.

The air-conditioning unit must have grounding to avoid hazard owing to insulation failure.

4.

All fitting lines must use crimp terminals or single wire. If multiple twisted wires are connected to terminal board, arc may arise.

5.

All line connections must conform to the schematic diagram of lines. Wrong connection may cause abnormal operation or damage of the air-conditioning unit.

6. Do not let any cable contact the refrigerant pipe, the compressor and moving parts such as fan.

7. Do not change the internal line connections inside the air-conditioning unit. The manufacturer shall not be liable for any loss or abnormal operation arising from wrong line connections.

Connection of Signal Line of Wire Controller

1. Open the cover of the electric box of the indoor unit.

2. Pull the signal cable of the wire controller through the rubber ring.

3. Plug the signal line of the wire controller onto the 4-bit pin socket(CN9) at the circuit board of the indoor unit.

4. Use cable fastener to bundle and fix the signal cable of the wire controller.

PIPE PREPARATION

OPERATION INSTRUCTIONS

REFRIGERANT PIPING WORK

Item

Model

GTH18K3BI

Size of Fitting

Pipe (mm)

Gas Liquid

Pipe Pipe

1/2”

1/4"

Max. Pipe

Length (m)

20

OPERATION INSTRUCTIONS

Max. Height

Difference between

Indoor Unit and

Outdoor Unit m

Amount of Additional

Refrigerant to be Filled

(For Extra Length of Pipe)

15 30g/m

GTH24K3BI

GTH36K3BI

GTH48K3BI

5/8” 3/8”

3/4” 1/2”

30

50

15

30

60g/m

120g/m

AIR PURGING AND CHECK OF PIPE LEAKAGE

OPERATION INSTRUCTIONS

LIQUID PIPE AND DRAIN PIPE

OPERATION INSTRUCTIONS

DRAIN PIPING WORK

OPERATION INSTRUCTIONS45

ROUTINE CHECK AFTER INSTALLATION

Check after installation

Items to be checked

Has it been fixed firmly?

Possible malfunction

The unit may drop, shake or emit noise.

Have you done the refrigerant leakage test?

It may cause insufficient refrigerating capacity.

Is heat insulation sufficient?

It may cause condensation and dripping.

Does the unit drain well?

Is the voltage in accordance with the rated voltage marked on the nameplate?

It may cause condensation and dripping.

It may cause electric malfunction or damage the part.

Is the electrical wiring and piping connection installed correctly and securely?

It may cause electric malfunction or damage the part.

Has the unit been connected to a secure earth connection?

It may cause electrical leakage.

OPERATION INSTRUCTIONS

Situation

Is the power cord specified?

It may cause electric malfunction or damage the part.

Has the inlet and outlet been covered?

Has the length of connection pipes and the

It may cause insufficient refrigerating capacity.

The refrigerating capacity is not accurate refrigerant charge been record?

WARNING!

1. This appliance is not intended for use by persons (including children) with reduced physical sensory or capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

2. Children should be supervised to ensure that they do not play with the appliance.

TEST RUNNING

OPERATION INSTRUCTIONS

EVALUATION OF THE PERFORMANCE

Check electrical main wire's voltage.

Use a thermometer to measure cool air both in and out.

The difference between in-air and out-air temperature should not be less than

Thermometer

Check

auto-restart function, it can remember the running model before power-broken.

Be sure to use the exclusive accessories list above in the installation. or it will lead to water leakage, electric shock, fire, etc.

Appendix:

Air conditioner nominal working condition and working range:

Test condition

Nominal cooling

Nominal heating

Rated cooling

Low temp. cooling

Rated heating

Note:

Low temp. heating

DB(C)

27

20

32

21

27

20

Indoor side

WB(C)

19

--

23

15

--

--

1. The design of this unit conforms to the requirements of EN14511 standard.

DB(C)

35

7

43

18(-7)

24

-7

Outdoor side

WB(C)

24

6

26

--

18

-8

2. The air volume is measured at the relevant standard external static pressure.

3. Cooling (heating) capacity stated above is measured under nominal working conditions corresponding to standard external static pressure. The parameters are subject to change with the improvement of products, in which case the values on nameplate shall prevail.

4. In this table, the outdoor side DB temperature of low temp cooling include two values, the one in the bracket is the working condition of the appliance with function of low temp cooling.

This product must not be disposed together with the domestic waste. This product has to be disposed at an authorized place for recycling of electrical and electronic appliances.

66129904712