McGraw-Edison CL-4C, CL-5 voltage regulator controls Software User's Guide
Below you will find brief information for voltage regulator controls CL-4C, voltage regulator controls CL-5. This guide is intended for users of the McGraw-Edison voltage regulator controls. It describes the software's functionality and helps users to understand the features and capabilities of the controls.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
▼
Scroll to page 2
of
30
COOPER CONTROL INTERFACE MCGRAW-EDISON © RD pr COOPER CL-4C Cooper Power Systems REGULATOR CONTROL = MCGRAW-EDISON © 1 ann? COOPER CL-5A Cooper Power Systems REGULATOR CONTROL MCGRAW-EDISON © ” COOPER CL-5C Cooper Power Systems REGULATOR CONTROL ] HOUR. MINUTE BAND INDICATOR VOLTAGE LIMITER ACCESSORY ACTIVE MONTH,DAY — DAT. o SET o TAE NOLTE OH DELAY DISPLAY 1 2 3 or Ll Di Uni Ow мА hte al Te POLTIGE FUNETIO 4 5 6 PUT Cor Lou VOLTAGE VOLTACE AEN HAMCE 7 8 9 || === COURTEE ENTER “lo > © + IETER SOURCE 1 ) a VOLTMETER EXTERNAL О] N NEUTRAL LIGHT O ) CONTROL FUNCTION — = / 1 OVER Ae AUTO /REMOTE RAISE INTERNAL or «© © oF = | e (O) MANUAL" LOWER DRAG HAND EXTERNAL y Ч ; RESET = SUPERVISORY DIFFERENTIAL VOLTMETER EXTERNAL ON MOTOR VOLTAGE | PANEL À a fr > Ÿ Я A Fr 2000 MeGraw-Edison? CL-4C and CL-5 Voltage Regulator Controls Software User”s Guide Applicable with Windows” 3.1, 3.11, and Windows” 95 ” COOPER Power Systems Bulletin 98002 March 1998 e New Issue Printed in USA COOPER POWER SYSTEMS COOPER CONTROL INTERFACE CL4/CL5 CONTROL USER GUIDE Information in this document is subject to change without notice. Companies, names, and data used in examples herein are fictitious unless otherwise noted. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose without the express written permission of Cooper Power Systems, Inc. ©1998 Cooper Power Systems, Inc. All rights reserved. Cooper Control Interface is a trademark of COOPER INDUSTRIES. Microsoft, MS-DOS, and Windows are registered trademarks of Microsoft Corporation. Windows 95 and Windows NT are trademarks of Microsoft Corporation. CL4/CL5 Cooper Control Interface User Guide CONTENTS Chapter 1 Introduction ........……................….….…...……0cesencenmencenerensenensermean0m mama nan saumon rennes 1 Chapter 2 Getting Started....…...........….....….….….cessrensanssansese nncuenanananonaneanane ene nanen nes 2 System Requirements .......................rrerereeeiriiierececeereccencer ree 2 What's in This Package .......................e.eesccerecirecococeereceererece enana correos 2 Installing and Configuring .................e..........eeeeereererrir re RR re eee eee 2 Installing In Windows 3.1 or 3.11 ......................+.6.11.mererereeerereere reee DD 3 Installing In Windows 95 eee ere 4 What's in This Manual ...........................eeceeciceierreiece reee eee. 4 What's Not in This Manual... reee ee eran reee 5 Where To Get Help .….…..................…...rercererensrenrerrrrrerrnera rares ere rac eee casa en anrnane ne 5 Chapter 3 Starting and Stopping the Program ...…....….....….….…..….…..ersencecsrenennecnnrense 6 Windows 3.1 and 3.11 - Program Manager .......................e.eesserecernvecererecene ee 6 Windows 95 - Start Menu.....................e.ee2reerveccireserrreoeeseenecerenre enero ecee reee. 7 Windows 95 - Desktop Shortcuts...........................r..eeeecscsrcecarrcerarrer ere eee 7 EXit...........ee.eeeccccereccececerenceraceoeseaececerarenvaseeeaece race eee e ete eaae ere eae e aera ranean ena, 7 Chapter 4 Working With Readings and Settings ..............-..--=...ee.suecaneneoveeaneno. 8 What are Readings and Settings? .......................eee..eeervececcrrerecereecenesereeeeo eee. 8 Create New Settings ...................e...r..eeeeeeiverrrreecereecrcerer reee erre reer 9 Open EXiStiNGg . . ..….…...…....….....crrereesserecaranrenrrrc censé nca nra nana en ca ner ras ra cases caen encre nee 9 Reviewing and Changing Data .......................r.—..eeseeereeerrreerreniee reo recenecen ee erecene. 9 All Settings ......................eeeeeecerceceirrecerrecenerer ee receeecereacere ener renEnerereraceLenermene 10 Individual Settings .…..............….....…....esrerecserensrece serre rar en sene ares ere c sera ea rr area enr ec 00e 10 Communications Settings..…..…..........................seerrrraeenareneenra carence nee nne ane nveee 10 Readings......................eímireceeeererenereeeere reee rereererrererenerereneenenerenerenareeeneee ee 11 Saving the Data on Your Computer........................e.....ee.eeeeereceerece DDD! 12 Deleting Data From Settings and Readings........................e..eemreereeeeecenene nee 12 Printing REPOS... oii rere errr eee eee esas nana 13 Chapter 5 Working With a COntrOl........….………ssrissseresenminnanaransrarsousaneenasen0enemmennee 14 Communicating Through the Server... ieee ea, 14 Making the Connection... reece 14 Receive The Control Settings and Readings ......................e=-..reeeeereierescrrreereeee. 15 Send Commands to a Control ….…..…........……...……reressecenrerene rare A 15 Reset the Indicators ina Control .….........…........…creeererrsrerers res ner sn eee re nc en ana ss 15 Set the Control Clock ....................e.e..eeeiimeeiercrerneree cer ee er errante 15 Chapter 6 Moving The Settings and Readings .................-....esecurrncaneoenooeneneoo. 16 What Can Be Moved? ......................eereserrececereneseoecceeecaneeceoonverenereore reee. 16 Move Data From One File To Another File On The Same Computer ................ 16 Move Data From One Computer To Another Computer ...........................e........ 17 Move Whole Data Files From One Directory To Another Directory.................... 17 Move Whole Data Files From One Computer To Another Computer................. 18 CL4/CL5 Cooper Control Interface User Guide Chapter 7 Troubleshooting and Operating TipS...…....….........….….…...….….…..…ccesssssarsen ses 19 Can't communicate with a Control ….….................crerrrerrseensenserenaan sean se nn aa cenan ne 19 Reports won't print .........................e...eeeresrersiecccereerc cenar eee eee. 19 Lost the Readings .........................eeeeserveerierriacecerecrecececarenereouee race eee eee. 19 For additional troubleshooting assistance..................... Dnornaceneere nene oe ene neo ares 19 Appendix A Manually Starting The CCI DDE Server .............-.—.--e--m=e...e-....—.. 20 Windows 3.1 and 3.11 - Program Manager .......................e.eeeserrererciererenceee e 20 Windows 95 - Start Menu .......................eneercevrrrerrcorre encerrar ee eee Doe. 21 Windows 95 - Desktop Shortcuts.......................e.e..esreesressereerere ID IDA 21 Appendix B Setting Up Communications To À Control... 22 Configuring the CCIDDE Server ………..…..........…..erersssrrrrrresesasencece sera re cannes access 22 PC Port Configuration... eee rere eee eae 22 Adding A New Control From DDE Server.........................==..ieeeeeeriicere rece ARE ERK KEG 22 Adding A New Control From The Interface Program e... 23 How The CCIDDE Server Works........................ereacecericereceriecenes eee eee 23 Using The CCIDDE Server With Other Programs.................................e.. ee... 23 Glossary ...............esesencesenenererceocaneeo rene anene aerea NENA ANee nene e Dean Ee ne nene nene NANO anne a nena aan enema 24 Baud Rate ....................eeeesiierreireceecccivereerevesoorenearaceneeenocercaoeaceoceere een reee 24 Communications Port......................e...e..e.e.eeerercecercececececes er erre 24 Communications Protocol...........................eeersreeeeeereee eee e eee 24 Control ID.....................e.cermresmocacececenerereecere recaer ereoe recen enero ere reee 24 eK rereenereneneerracereeeaereare recen aanan 24 Data PoOrt..….........................ecrecerecenensee mere sera nee nana mere race rec caearereao recae ererrecanee 24 Demand Metering Date/Time Stamp .….….............…...…rrrrerrecenrenenererrerrnrerasrenn ces 24 REAding...............…...............crcresrrece sers cc nsrrenserece errr rere eraser arenes ranean 24 SETlINGS .......................rccreccreeccrrecererce sens erane eee nana nrenen sera rence senc serre re a ce senc nana 25 11 CL4/CL5 Cooper Control Interface User Guide Chapter 1 Introduction The Cooper Control Interface CL4/CLS Control program is a powerful, interactive Windows tool to send and receive data from a CL-4C, CL-SA, and CL-5C Regulator Control, and to review readings and update settings while off-line from the Control. Here is a list of some of its features: Easy to use Windows screens with simple menus, scrolling lists of choices and simple mouse-click selections. On-screen messages show acceptable data ranges. Create settings by modifying an existing file and saving it with a new name. Print reports on any Windows compatible printer without difficult printer and report configuration steps. Communication to a Control through a new server for simplified configuration and connections. The Cooper Control Interface"M program helps you maintain controls. Field technicians can interact directly with Controls. Engineers in an office can work with a copy of the settings and readings from a Control. Build settings for a new Control from scratch or copy and modify the file from another Control on a computer in the office, then copy the settings to a laptop computer to send to the Control in the field. Build standard configuration settings and use them to setup new Controls to ensure that similar Controls will have similar setups. Receive readings and settings into a laptop computer from a Control in the field, and then transfer the data files to an engineering computer in the office for analysis and reporting. Look at saved readings and settings files to compare setups and results to help make engineering recommendations. Operate and interrogate a Control, and update its settings from the laptop PC in the field. The files, both settings and readings, are in a non-proprietary database (dBase) format for easy use by other applications, such as spreadsheets and databases. Year 2000 compliant. Chapter 1 Introduction 1 CL4/CL5 Cooper Control Interface User Guide Chapter 2 Getting Started System Requirements The Cooper Control Interface program can run on any system with Windows 3.1, Windows 3.11 or Windows 95. This version of the software is not compatible with Windows NT. The recommended minimum system 1s a PC with a 33 MHz 486 Intel CPU and 8 MB of memory. Connection to a Control requires an available RS-232 serial port on your PC. Any Windows compatible printer can be used to print reports. What's in This Package The Cooper Control Interface program package includes a set of installation diskettes and this manual. The diskettes include the programs, on-line help files, factory default settings, sample readings, and the support files. Communications through the control’s data port requires a Data Port-to-Computer Interface cable. This cable is not part of this package but can be purchased separately. Installing and Configuring The installation diskettes contain a setup program that will guide you through the installation process. In most cases, you should accept the default answers it proposes for each question. You may want to change some of the options but be sure to read the recommendations on each screen. The installation diskettes may contain a “ReadMe.txt” file with new information that became available after this manual was printed. The installation program will ask if you want to view the file. The CCI DDE communications server will be installed as part of the Core Disk installation. This installation uses standard Windows procedures. Chapter 2 Getting Started 2 CL4/CL5 Cooper Control Interface User Guide Installing In Windows 3.1 or 3.11 1 Quit all running applications. 2 Insert Core Disk 1 in the floppy drive. These instructions assume you are using Drive A. If you are using a different floppy drive, substitute your drive letter in place of A. | 3 From the File menu in Program Manager, choose Run. New Open Enter Move... F7 Copy... Fa Delete Del Properties... Alt+Enter Exit Windows... Command Line: | a:\setup [] Run Minimized 5 Follow the instructions on the screen to complete the installation. Click Yes when the installation program asks if you wish to install the CLACLS application. Chapter 2 Getting Started 3 CL4/CL5 Cooper Control Interface User Guide Installing In Windows 95 1 Quit all running applications. 2 Insert Core Disk 1 in the floppy drive. These instructions assume you are using Drive A. If you are using a different floppy drive, substitute your drive letter in place of A. ‘ 5 Follow the instructions on the screen to complete the installation. Click Yes when the installation program asks if you wish to install the CLACLS application. What's in This Manual This User Guide describes the Cooper Control Interface CL4/CLS Control program and the basic procedures you can do with it. It tells you about the system requirements and how to install it. It also describes the DDE communications server that is used to communicate with attached controls. You most likely will not need to read about the server unless you are an advanced user who needs to set up a new control type. Chapter 2 Getting Started 4 CL4/CL5 Cooper Control Interface User Guide What's Not in This Manual This manual does not discuss how to use Windows dialog boxes and menus, how to use the keyboard and mouse, or other computer operation functions. The manuals with your computer and the on-line help in Windows can show you how to do these tasks. Nor does this manual discuss the details of the CL-4C, CL-5A, and CL-5C Controls. You will need the Service Information Manuals for the Controls for guidance on how to set and interpret the settings and readings. These manuals are S225-10-4C for the CL- 4C control and S225-10-10 for the CL-5A and CL-5C. For copies of these manuals, contact your local Cooper Power Systems representative. Where To Get Help You can get help showing you how to do the basic procedures by choosing Help from the menu or clicking the help toolbar button in the program. Look at the "How do I …" sections for most common questions or check the table of contents for specific items. You can get help on the screen by pressing the F1 function key. The Service Information Manual (S225-10-4C or S225-10-10) for the Control you are working with will tell you how to set it up and help you analyze the data. See also Chapter 7 Troubleshooting and Operating Tips. Chapter 2 Getting Started 5 CL4/CL5 Cooper Control Interface User Guide Chapter 3 Starting and Stopping the Program Windows 3.1 and 3.11 - Program Manager The installation adds the Cooper Power Systems program group to program manager. To start the Cooper Control Interface CL4/CL5 Control program in Windows 3.1 and 3.11: 1 Open the Cooper Power Systems group in Program Manager Free de EE Program Manager Options Window Help Cooper Power Systems gg Ао Help for F4C Help for FAC CLACLS # a Ti EA e o и y Jn E DATAREAD Helpfor (Comm Server Help for Comm DATAREAD AS Feedback 2 Open the Cooper Control Interface CLACLS Control program by double-clicking on the CLACLS 1con Chapter 3 Starting and Stopping the Program 6 CL4/CL5 Cooper Control Interface User Guide Windows 95 - Start Menu The installation adds the Cooper Power Systems program group to the start menu. To start the Cooper Control Interface CL4/CLS Control program in Windows 95: 1 Click on the Start button and select Programs 2 CI = Co oper Fawer System Windows 95 - Desktop Shortcuts For convenience, you can place a shortcut to CLACLS on your Windows 95 desktop. You can find instructions for creating shortcuts in the Windows 95 Help on the start menu. If you have a shortcut on your desktop, simply double-click on the icon to start the program. Shortcut to Cldcl5.exe Exit Exit from the program by choosing File | Exit on the menu or clicking Exit on the toolbar. Chapter 3 Starting and Stopping the Program 7 CL4/CL5 Cooper Control Interface User Guide Chapter 4 Working With Readings and Settings What are Readings and Settings? Controls store two types of data: settings and readings. Settings are the control programming parameters that set up how the control operates. The Cooper Control Interface lets you receive the settings from a control so you can review them, change them, or save them for later use. Settings that you have changed but not saved are displayed in blue. The program also lets you create new settings and upload them to a control. A settings file on your computer can be transferred to another computer for review and modification. You can receive a settings file from someone else and upload it to a control attached to your PC. A reading is settings plus the output of metering, load profile, and event/profile recorders in the control. The metering, load profile, and event/profile recorder data tell you how the system and device that the control operates with is performing. The Cooper Control Interface lets you receive the readings from a control so you can analyze them. You can view them on the screen and print reports. A readings file can be sent to another computer for review. The metering, load profile, and event/profile recorder data in readings are informational. Settings are programmable. You can create new settings or modify existing settings, and then upload them to a control. You can also “read” the settings from an existing control and review them in a window. Some windows in the program display only the informational part of a reading from a control where you can view the information and print reports, but you cannot change the data. Other windows display settings and allow you to change them. Settings for a control are stored as “settings” records in the computer data base, and readings from the same control are saved as “readings” records. When you work with data records stored on your computer, you choose to open either settings or readings, depending on what work you intend to do. Chapter 4 Working With Readings and Settings 8 CL4/CL5 Cooper Control Interface User Guide Create New Settings You can build settings for a new control by selecting File | New Settings from the menu or by clicking the New Settings button on the toolbar. You will be asked to choose settings from an existing file as a base for the new settings. The existing file you choose can be a readings file; the program will get only the. settings from the file. Readings saved from the Cooper Control Interface Data Reader program can be selected. New settings can be based on settings and readings from the MS-DOS based program after they have been converted to the dbf file format. Settings and readings from the MS-DOS based program may be converted to the dbf file format by using the DBTRANS utility. Execute the DBTRANS utility and select the files you wish to translate. These would typically be in subdirectories ending in “.CKT” under the “C\DATAREAD” directory (e.g. “C:\DATAREAD\DEV15.CKT\"). The DOS-style files are named according to the device ID and end in “.DAT”. Select as many of these as you wish and click on the “Convert” button to have them translated into DBF format. The readings and settings thus converted will be placed in files named “READINGS.DBF” and/or “SETTINGS.DBF” in the same directory. After all the settings are correct, you can save them in a file or send them to a control. Open Existing . .. If you have settings or readings stored in files on your PC, you can open them in the program. Choose Open Settings or Open Readings from the File menu or click one of the open buttons on the toolbar. You will be asked to choose the file that contains the data, and then select the reading or settings you want to view. The existing file you choose can be a readings file; the program will get only the settings from the file. Or you can choose Recent Settings or Recent Readings from the File menu. You will be asked to select a recent reading or setting. The settings you open from a file can be modified and saved or sent to a control. The file you open could have been saved during a communications session with a control, or it could be from another computer. Readings saved from the Cooper Control Interface Data Reader program can be selected. Settings and readings from the MS-DOS based program can be opened by this version of the program after they have been converted to the dbf file format. See Create New Settings for information on how to convert data files from the MS-DOS based program to the dbf file format. Reviewing and Changing Data For more information on how to interpret settings and readings, see the Service Information Manuals (5225-10-4C or $225-10-10). Chapter 4 Working With Readings and Settings 9 CL4/CL5 Cooper Control Interface User Guide All Settings Use "All Settings" to display Basic Control, Configuration, Voltage Limiter, Voltage Reduction, Profile Recorder, and Security settings in one dialog. All settings is displayed automatically when you get new settings or open settings. Changes you make on this screen Will be displayed immediately in the corresponding individual setting dialog if they are open. If you make a change in one of the individual setting dialogs, it will also be displayed immediately in the All Settings view. Blocking Status Blocking Status can be set and viewed on this screen. Blocking status also appears on the Operate screen. Individual Settings Basic Control Settings Set and view the basic voltage regulator operating parameters including forward and reverse values for set voltage, bandwidth, time delay, and line drop resistance and reactance. Also change the Reverse Sensing Mode settings. Configuration Set and view control configuration data including the control identification, wiring configuration (Wye or Delta), control operating mode, and sensor and type information. Also display - but not set - the date and time in a connected control. See the "Set Control Clock" menu choice to set the date and time. Voltage Limiter Set and view the voltage limiter mode, and the high and low output voltage limits of the regulator. Voltage Reduction Set and view the regulator voltage reduction settings of the control. Profile Recorder Select the four instantaneous values that will be tracked in the control profile recorder. Available only for the CL-5A and CL-5C controls. Security View the control manual access security codes (passwords). Set and view the Security Override Code for the CL-5A and CL-5C controls. NOTE: See the discussion of security codes in the Service Information Manual (S225-10-10) before changing the Security Override code. Communications Settings Communications Settings Set and view the communications parameters for the control. This does not affect the PC. Only the values appropriate for the connected control are displayed. NOTE: Settings from this dialog are not included in "All Settings". Chapter 4 Working With Readings and Settings 10 CL4/CL5 Cooper Control Interface User Guide Readings Instantaneous Metering Displays instantaneous meter readings from the regulator sensors. Not available when settings are being viewed. Demand Metering - Forward Demand Metering - Reverse Displays demand metering values from the control. See the Service Information Manuals (S225-10-4C or S225-10-10) for an explanation of the metering and reporting algorithms. Not available when settings are being viewed. Click the reset button to reset the values. Click on the selection boxes to choose which items to reset. If you mark none, the program will ask if you want to reset all of them. Reset is not available unless the program is communicating with a control or has just obtained a reading from a control. Status Displays the status of the control functions. Not available when settings are being viewed. Diagnostics Displays diagnostic data about the processor in the control. Not available when settings are being viewed. Click the reset button to reset the values. Click on the selection boxes to choose which items to reset. If you mark none, the program will ask if you want to reset all of them. Reset is not available unless the program is communicating with a control or has just obtained a reading from a control. Calibration View the calibration values for the control. Not available when settings are being viewed. Profile Data Display profile data from a CL-5A or CL-5C for four metered values recorded once every 15 minutes over the past 30 hours. The program obtains profile data only once, either when the dialog 1s first displayed or when communications are started. When communicating over 2179 protocol, the control resets the profile data automatically after sending it to the PC. Not available when settings are being viewed. Operate Use this dialog to operate a control while communicating from the program. Change the tap position and the blocking status. The dialog also displays the metering values that are available on the front panel of a control. Available only while communicating. When you click a button, the program sends the command to the control immediately. It does not change the settings in the program on your PC. Your display screen will be updated when the control sends information to the PC. Chapter 4 Working With Readings and Settings 11 CL4/CL5 Cooper Control Interface User Guide Saving the Data on Your Computer The interface program can contain settings and readings that were obtained from a control during communications. Or it may contain settings that you got from another file and may have changed. You can save the data on the disk in your PC for later use: e If you are communicating with a control, you must stop communications. When you stop communications, the program asks if you want to keep the settings or obtain the readings from the control. Choose to keep the settings if you want to save them. Obtain the readings if you want to save those instead. e Select File | Save or click the diskette button on the Toolbar. If you are not already working on a file that you opened with Open Readings or Open Settings , Save will behave like a Save As so you can name the file you are saving. e Select File | Save As if you want to create a new file and supply a name for it. The program will save the data as settings or readings, depending on which type 1s in the program at the time. You can save the data on your hard drive or on a floppy disk. Note: The program was not intended to be used with a common central database (e.g. on a network). Saving data from more than one PC to the same database at the same time can produce unpredictable results. Deleting Data From Settings and Readings You can delete selected readings and settings from your computer files when you no longer need them. Other data in the same file will not be deleted. Choose Delete Readings or Delete Settings from the File menu, and then select the file that contains the data you want to delete. The program will list the readings or settings contained in the file you select. Choose one or more to delete. Deleting data from a file does not affect the data currently in the program. Deleting all readings or settings from a file does not delete the file itself. You can delete the file by using File Manager in Windows 3.1 and 3.11, or by using Windows Explorer in Windows 95. Chapter 4 Working With Readings and Settings 12 CL4/CL5 Cooper Control Interface User Guide Printing Reports You can print the settings and readings 1n reports. Choose File | Print on the menu or click the print button on the toolbar. The program asks you what data to include from the reading or settings that it currently has. Reports for settings contain the function code, value, unit of measure, and description. Reports for profile data contain entry number, time, and the four parameter values. If you would like to see the report before printing 1t, use the File | Print Preview menu choice or click the print preview button on the toolbar. While in print preview, you can: Change pages by using the arrow buttons. Send the report to the printer by clicking the printer button. Export the report to miscellaneous destinations (including text file) by clicking the export (envelope) button. Follow the screen prompts. Change the magnification by clicking the magnify button. Return to the program by closing the print preview window. Chapter 4 Working With Readings and Settings 13 CL4/CL5 Cooper Control Interface User Guide Chapter 5 Working With a Control Communicating Through the Server You can connect your PC to a Control to receive settings and readings from it, to send new settings to it, and to operate it. The Cooper Control Interface communicates with a control through a CCIDDE Server program that starts automatically when you ask for a connection. The CCIDDE Server handles the protocol conversions and communications channel control for each type of control. See Appendix B Setting Up Communications To A Control for more information about the server. Making the Connection If you are connecting to the data port: 1 Connect the Data Port-to-Computer Interface cable from the COM port on your PC to the Data Port on the control. 2 Choose Control | Start Communicating from the menu or click the Start Communicating button on the toolbar. The Select Control dialog will be displayed. 3 Click on the Data Port button. The program will get the control identification from the control and try to match it to one of the configured controls. If one match is found, you will be asked to confirm that it is correct. If more than one match is found, you will be asked to choose the correct control from among the matches. If no matches are found, you will be asked to enter a name for the new control and the control will be automatically configured in the DDE server. Instead of clicking on the data port button, you can select a configured control from the list and click OK. 4 The status on the Toolbar will show COMMUNICATING when the connection is ready. If you are connecting to the communications port: 1 Connect a serial cable from the COM port on your PC to the serial connection of the control. 2 Choose Control | Start Communicating from the menu or click the Start Communicating button on the toolbar. The Select Control dialog will be displayed. 3 Find the control you want in the list and select it. If the control is not in the list, then you must add it by using the DDE Server (see Appendix B Setting Up Communications To A Control). Click OK to start communicating. 4 The status on the Toolbar will show COMMUNICATING when the connection is ready. Chapter 5 Working With a Control 14 CL4/CL5 Cooper Control Interface User Guide Receive The Control Settings and Readings While you are communicating with a control, you can receive its settings and readings. To get the settings: If the status shows NOT COMMUNICATING, you must start communications as described previously. As soon as the communications start, the program gets all the settings from the control. You can examine and change the settings by selecting All Settings, Individual Settings, or Communications Settings from the Window menu. To get a reading: You can get a reading from the control by selecting Control | Obtain Reading from Control from the menu or clicking on the Obtain Reading From Control button on the Toolbar. If you are not already communicating with the control, the program will start communications and ask you which control you want to access. As soon as the reading is obtained, you can view Instantaneous and Demand Metering, Status, Diagnostics, Calibration, and Profile Data information by selecting them on the Window menu. Send Commands to a Control While your PC is communicating with a control, you can operate the manual operations mode of the control from this program. 1 If the status shows NOT COMMUNICATING, you must start communications as described previously. 2 Choose Window | Operate from the menu. The Operate dialog will open. 3 You can see the status of the control. You can operate the control by clicking on the buttons. Reset the Indicators in a Control You can reset the indicators in the control. First click on the reset selection box to put a check mark for each item to be reset. Then press the Reset button in the dialog box or choose Control | Reset Indicators on the menu or click the reset button on the Toolbar. You may reset marked indicators, demand metering and tap position indicators, or all indicators. Marked indicators are those that have been marked in dialogs. Set the Control Clock You can check and set the clock in a control. Choose Control | Set Control Clock on the menu or click the clock button on the toolbar. The current date/time in the control will be displayed. You can set the control clock to the PC’s clock or a specified date/time. А СТАС does not have a real-time clock, so this menu option will be disabled while communicating to a CL4C. Chapter 5 Working With a Control 15 CL4/CL5 Cooper Control Interface User Guide Chapter 6 Moving The Settings and Readings What Can Be Moved? Settings on an office computer may have to be moved to a notebook computer so it can be taken to a control in the field. Or settings and readings from a control may be saved on a notebook computer, but they are needed for review on a computer in an engineering office. Settings and readings may need to be copied to a central location. Settings and readings are saved in files with an extension of “dbf”. The files can be copied, moved and deleted like any other file on your PC. They can be transferred from one computer to another on diskettes, over a network or by modem connections. The instructions below show you how to: Move data (settings or reading) from one file to another file on the same computer. Move data (settings or reading) from one computer to another computer. Move whole data files from one directory to another directory. Move whole data files from one computer to another computer. Move Data From One File To Another File On The Same Computer Start the Cooper Control Interface program on the computer that has the data to be moved. Use File | Open Settings, File | Recent Settings, File | Open Reading, or File | Recent Reading to open the data (settings or reading) that is to be moved. Use File | Save As to save the data (settings or reading) in the desired file. The file can be on the local hard drive or on a network drive. The file can be a new file or it can be an existing file. The data will still exist in the file from where it was moved. If desired, use File | Delete Settings or File | Delete Reading to remove the data from that file. Chapter 6 Moving The Settings and Readings 16 CL4/CL5 Cooper Control Interface User Guide Move Data From One Computer To Another Computer Start the Cooper Control Interface program on the computer that has the data to be moved (the source PC). Use File | Open Settings, File | Recent Settings, File | Open Reading, or File | Recent Reading to open the data (settings or reading) that is to be moved. Insert a diskette in the floppy drive of the source PC. Use File | Save As to save the data (settings or reading) to a file on the diskette. Choose the floppy drive (usually drive A) in the Save As dialog. The data will still exist in the file from where it was moved. If desired, use File | Delete Settings or File | Delete Reading to remove the data from that file. Move the diskette to the floppy drive of the computer that is to receive the data (the target PC). Start the Cooper Control Interface program on the target PC. Use File | Open Settings or File | Open Reading to open the data. Choose the floppy drive (usually drive A). Choose the file that was saved earlier. Use File | Save As to save the data (settings or reading) in the desired file on the target PC. The file can be on the local hard drive or on a network drive. The file can be a new file or it can be an existing file. Move Whole Data Files From One Directory To Another Directory If you are familiar with the File Manager in Windows 3.11 or with Windows Explorer in Windows 95, you can use either of these tools to copy files from one directory to another directory. Refer to the Windows on-line help if you need more information or look for the file copy topics in the Windows User Guide. Open the directory where the data file is stored on your PC (the source directory) in one panel of File Manager or Windows Explorer. The directory can be on the local hard drive or on a network drive. Open the directory where you want to move the data file (the target directory) in another panel. The directory can be on the local hard drive or on a network drive. If the target directory already has a file with the same name as the file you are moving, then rename the file in the target directory. If you do not rename the file, you will lose the existing data in that file. Be sure to keep the “.dbf” file extension. In the source directory, locate the file you want to move. Click and hold the mouse button while you drag the file from the source directory to the target directory. Chapter 6 Moving The Settings and Readings 17 CL4/CL5 Cooper Control Interface User Guide Move Whole Data Files From One Computer To Another Computer If you are familiar with the File Manager in Windows 3.11 or with Windows Explorer in Windows 95, you can use either of these tools to copy files from one computer to another computer. Refer to the Windows on-line help if you need more information or look for the file copy topics in the Windows User Guide. On the computer that has the data to be moved (the source PC), open the directory where the data file 1s stored (the source directory) in one panel of File Manager or Windows Explorer. The directory can be on the local hard drive or on a network drive. Insert a diskette in the floppy drive of the source PC. Open the floppy drive (usually drive A) in another panel of File Manager or Windows Explorer. Click and hold the mouse button while you drag the file from the source directory to the floppy drive. Move the diskette to the floppy drive of the computer that is to receive the data (the target PC). On the target PC, open the floppy drive (usually drive A) in one panel of File Manager or Windows Explorer. Open the directory where you want to move the data file (the target directory) in another panel. The directory can be on the local hard drive or on a network drive. If the target directory already has a file with the same name as the file you are moving, then rename the file in the target directory. If you do not rename the file, you will lose the existing data in that file. Be sure to keep the “.dbf” file extension. In the panel for the floppy drive, locate the file you want to move. Click and hold the mouse button while you drag the file from the floppy drive to the target directory. Chapter 6 Moving The Settings and Readings 18 CL4/CL5 Cooper Control Interface User Guide Chapter 7 Troubleshooting and Operating Tips Can't communicate with a Control If you are unable to receive readings or settings from a control, the problem most likely will be with the cable or the setup. First check to be sure that you have the correct cable and that it is securely plugged into the control and into the correct port on your PC. For data port connections, be sure that correct end of the Data Port-to-Computer Interface cable 1s plugged into the data port. If the cable is secure, verify that you have the correct setup in the CCIDDE program. Be sure you have specified the correct control type and that the communications parameters are correct. Reports won't print The report printing program uses the printer you have setup in Windows. There are no parameters you need to change within the Cooper Control Interface program. If your reports do not print properly, verify that you have the correct printer setup in Windows and use the Windows help process to identify what 1s wrong. Remember that other applications may be used to open and print the data. Lost the Readings When you receive profile data or demand metering date/time stamps from a control using the 2179 protocol, the control automatically resets the data. You must save the data to a file on your PC 1f you want to view the data later. You cannot retrieve the data from the control a second time using the 2179 protocol. The data can always be retrieved using the data port. For additional troubleshooting assistance You may contact Cooper Power Systems: e Customer Service Center: (414) 524-3300 e Internet web address: www.cooperpower.com e Local Cooper Power Systems Representative Chapter 7 Troubleshooting and Operating Tips 19 CL4/CL5 Cooper Control Interface User Guide Appendix A Manually Starting The CCI DDE Server Windows 3.1 and 3.11 - Program Manager The installation adds the Cooper Power Systems program group to program manager. The DDE Server 1s started automatically when needed by other Cooper Control Interface programs. To manually start the Cooper Control Interface DDE Server in Windows 3.1 and 3.11: 1 Open the Cooper Power Systems group in Program Manager Program Manager File Options Window Help CL4CL5 Help for FAC Help for FAC CLACL5 Help for DATAREAD Feedback 2 “Open the Cooper Control Interface DDE Comm Server by double-clicking on the Comm Server icon te Comm Server Appendix A Manually Starting The CCI DDE Server 20 CL4/CL5 Cooper Control Interface User Guide Windows 95 - Start Menu The installation adds the Cooper Power Systems program group to the start menu.. The DDE Server is started automatically when needed by other Cooper Control Interface programs. To manually start the Cooper Control Interface DDE Server program in Windows 95: 1 Click on the start button and select Programs Windows 95 - Desktop Shortcuts For convenience, you can place a shortcut to the DDE Server on your Windows 95 desktop. You can find instructions for creating shortcuts in the Windows 95 Help on the start menu. If you have a shortcut on your desktop, simply 7 double-click on the icon to start the program. He Shorteut to Ceidde.exe Appendix A Manually Starting The CCI DDE Server 21 CL4/CL5 Cooper Control Interface User Guide Appendix B Setting Up Communications To A Control Configuring the CCIDDE Server The CCIDDE Server handles communications between programs on your PC and an attached control. The server is able to automatically configure the PC communications port speed to work with a control. However, you must configure some items for it. The configurable items are described here. Consult the on-line help in the CCIDDE program for detailed instructions. To access the configuration menu, start the CCIDDE server program by double-clicking the CCIDDE icon in the Windows 3.1 Program Manager or in the Cooper Power Systems group in the Windows 95 start menu and select Configure from the menu bar. If you will only connect to the Data Port of a control, then configuration of the DDE server will not be required for proper operation. See the Service Information Manual for your control for more information on the communications parameters for your control. PC Port Configuration Choose the Configure | PC Connection menu from the CCIDDE program to setup the PC port. The program lets you set the address for the PC and select the COM port where you will connect the cable. The address defaults to 1 (one) and should not normally be changed. This identifies the PC as device number 1 in the connection. Adding A New Control From DDE Server You can add controls and control groups. Each control must belong to a group, and a group can consist of one or more controls. Choose Configure | Control Definition from the CCIDDE program to add or change controls and groups. When you define a group, you must set the protocol, group name and baud rate. You can choose AUTO Baud Rate and let the server determine the rate. When you define a control, you must set its name and type, and you must assign it to a group. You can specify any name that will help you identify the control later. You must specify the protocol used by the communications link. The data port uses the 2175 protocol. The communications port of the control uses either the 2200 or 2179 protocol. Controls with the 2200 protocol are supported only through the data port or the DOS based program (contact your Cooper Power Systems representative). If the group uses 2179 protocol, you must also assign the control address. Each control in a group must have a unique address different from the PC so that the CCIDDE Server can send messages to each control individually. Appendix B Setting Up Communications To A Control 22 CL4/CL5 Cooper Control Interface User Guide Adding A New Control From The Interface Program A new control can be added to the Data Port group of the DDE Server from the CL4/CLS or F4C Control programs. See Making The Connection in Chapter 5 or the on-line help topic Select a Control for more information. Controls using the 2179 protocol cannot be configured from the Cooper Control Interface CL4/CLS or F4C Control programs. These controls must be added from the DDE Server. How The CCIDDE Server Works The CCIDDE Server accepts DDE requests from other programs such as the CL4/CL5 or F4C Control programs. It translates the requests into the appropriate protocol for the control, sends the command or request through the communications port, reads the response from the control, and translates the response into a DDE response for the calling program. This design allows many different programs to communicate with a control without the need for configurations and communication control in each one. The DDE server can be upgraded to provide additional protocols and support for new devices without requiring all of the accessing programs to be changed. Using The CCIDDE Server With Other Programs A list of DDE commands for the CCIDDE Server is available from Cooper Power Systems if you are interested in creating your own programs to access controls through the server. However, building DDE programs is a task for experts. Appendix B Setting Up Communications To A Control 23 CL4/CL5 Cooper Control Interface User Guide Glossary Baud Rate The speed in bits per second for the serial data transfer between the computer and the control. See the Service Information Manuals (S225-10-4C or 8225-10-10) for information about the baud rates each control supports. Communications Port The is a real-time digital communications link from a control to other devices. It is not the port on the front panel of the control. See also Data Port. Communications Protocol The “language” used by the control and your PC when they communicate. When you configure a control in the CCIDDE program, you specify which protocol it uses. See the Service Information Manuals (S225-10-4C or §225-10-10) for information about the protocols each control supports. The 2175 protocol is used by the data port. The 2179 protocol 1s the communications port protocol supported by this program. The 2200 protocol 1s not supported by this program. Control ID The number programmed into a control to uniquely identify it. The control ID is used to find the correct configured control when you communicate with a control and you click the Data Port button. Control Type Identifies the type of a control: CL-4C, CL-5A, or CL-5C. Data Port The front panel 9-pin port on the control where you attach the Data Port-to-Computer Interface cable. This port is NOT an RS-232 port. The Data Port uses the 2175 protocol. See also Communications Port. Demand Metering Date/Time Stamp The demand metering values are date and time stamped for the CL-5A and CL-5C. Date and time stamps are not available for the CL-4C control. Reading A reading 1s settings plus the output of metering, load profile, and event/profile recorders in the control. The metering, load profile, and event/profile recorder data tell you how the system and device that the control operates with is performing. The Cooper Control Interface lets you receive the readings from a control so you can analyze them. You can view them on the screen and print reports. A readings file can be sent to another computer for review. Glossary 24 CL4/CL5 Cooper Control Interface User Guide Settings Glossary Settings are the control programming parameters that set up how the control operates. The Cooper Control Interface lets you receive the settings from a control so you can review them, change them, or save them for later use. Settings that you have changed but not saved are displayed in blue. The program also lets you create new settings and upload them to a control. A settings file on your computer can be transferred to another computer for review and modification. You can receive a settings file from someone else and upload it to a control attached to your PC. 25 McGraw-Edison CL-4C and CL-5 Voltage Regulator Controls Software User's Guide ” GOOPER Power Systems © 1998 Cooper Power Systems McGraw-Edison is a registered trademark of Cooper Industries, Inc. P.O. Box 1640 Waukesha, WI 53187 Windows is a registered trademark of Microsoft, Inc. www.cooperpower.com KA2048-459
advertisement
Key Features
- Send and receive data
- Review readings and update settings
- Create new settings by modifying an existing file
- Print reports on any
- Communication to a control through a new server
- Build settings for a new control from scratch or copy
- Build standard configuration settings
- Receive readings and settings into a laptop computer
- Operate and interrogate a control
- The files, both settings and readings, are in a non-proprietary database
Frequently Answers and Questions
Can I print a report without configuring the printer?
Yes, you can print reports on any Windows compatible printer without difficult printer and report configuration steps.
How do I connect to a control?
You can connect your PC to a Control to receive settings and readings from it, to send new settings to it, and to operate it. Connect the Data Port-to-Computer Interface cable from the COM port on your PC to the Data Port on the control.
What data formats can be used with the program?
Settings and readings are saved in files with an extension of “dbf”. The files can be copied, moved and deleted like any other file on your PC.
What are settings?
Settings are the control programming parameters that set up how the control operates. You can receive the settings from a control so you can review them, change them, or save them for later use.
What are readings?
A reading is settings plus the output of metering, load profile, and event/profile recorders in the control. The metering, load profile, and event/profile recorder data tell you how the system and device that the control operates with is performing.