- Industrial & lab equipment
- Electrical equipment & supplies
- KB Electronics
- APRM-PC
- Owner's manual
- 14 Pages
KB Electronics APRM-PC Owner Manual
KB Electronics APRM-PC is an Anti-Plug Reversing Module (APRM) with dynamic braking. It is designed for use with KBPC-240D speed control and offers a range of features and capabilities. The APRM-PC helps prevent motor damage by automatically reversing the motor's direction if it detects a sudden change in load, such as when a conveyor becomes jammed. Its dynamic braking feature provides quick and controlled deceleration of the motor, reducing the risk of damage to the motor and driven equipment.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
“The Right Control for Your Application.”
12095 NW 39 Street, Coral Springs, FL 33065-2516
Telephone: 954-346-4900; Fax: 954-346-3377
www.kbelectronics.com
Installation and Operation Manual Supplement for Anti-Plug Reversing Module (APRM) (Part No. 9378)
FOR USE WITH MODEL KBPC-240D
This supplement is for the APRM Installation and Operation Manual Rev. B (Part No. A40265).
The manual must be read and understood before installing and operating the drive.
For further assistance, contact our Sales Department at 954-346-4900 or Toll Free at 800-221-6570 (outside Florida).
DESCRIPTION OF CHANGES AFFECTING THE MANUAL
(The Parts List and Schematic (Table 4 and Figure 6, on pages 7 and 8) no longer apply to the SMT APRM and should not be used.)
TABLE 2 – GENERAL PERFORMANCE SPECIFICATIONS
Updated to show the correct Operating Temperature Range and Braking Time.
Replaces Table 2, on page 2 of the manual.
Parameter Specification
AC Line Input (50/60 Hz) (Jumper Selectable) (Volts AC)
Maximum Run/Brake or Forward/Reverse Operations per Minute*
Ambient Temperature Range (°C / °F) 0 – 40 / 32 – 104
*Based on a one (1) second braking time.
TABLE 3 – INTERCONNECTING WIRE HARNESS
Replaces Table 3, on page 5 of the manual.
Wire Color Location on Drive Wire Termination
Red A1A
115 or 208/230
4
Orange A1B
White A2B
Gray I1
White / Black I2
Brown* CON2
*The brown wire has been added to CON2.
FIGURE 2 – REMOVAL OF DRIVE JUMPERS
Updated to show CON2.
Replaces Figure 2, on page 4 of the manual.
(A42048) – Rev. A00 – 5/4/2010
Continued on other side…
Page 1 of 2
“The Right Control for Your Application.”
12095 NW 39 Street, Coral Springs, FL 33065-2516
Telephone: 954-346-4900; Fax: 954-346-3377
www.kbelectronics.com
Installation and Operation Manual Supplement for Anti-Plug Reversing Module (APRM) (Part No. 9378)
FOR USE WITH MODEL KBPC-240D
…continued from other side.
FIGURE 5 – INTERNAL WIRING DIAGRAM
Updated to show the SMT PC board and the brown wire on the Interconnecting Wire Harness.
Replaces page 6 of the manual.
KBPC-240D and APRM
Gray
White/Black
Red
Black
White
Orange
Black
White
Red
Brown
Yellow
(A42048) – Rev. A00 – 5/4/2010 Page 2 of 2
“The Right Control for Your Application.”
12095 NW 39 Street, Coral Springs, FL 33065-2516
Telephone: 954-346-4900; Fax: 954-346-3377
www.kbelectronics.com
Installation and Operation Manual Supplement for Anti-Plug Reversing Module (APRM) (Part No. 9378)
FOR USE WITH MODEL KBPW-240D
This supplement is for the APRM Installation and Operation Manual Rev. B (Part No. A40265).
The manual must be read and understood before installing and operating the drive.
For further assistance, contact our Sales Department at 954-346-4900 or Toll Free at 800-221-6570 (outside Florida).
DESCRIPTION OF CHANGES AFFECTING THE MANUAL
(The Parts List and Schematic (Table 4 and Figure 6, on pages 7 and 8) no longer apply to the SMT APRM and should not be used.)
TABLE 2 – GENERAL PERFORMANCE SPECIFICATIONS
Updated to show the correct Operating Temperature Range and Braking Time.
Replaces Table 2, on page 2 of the manual.
Parameter Specification
AC Line Input (50/60 Hz) (Jumper Selectable) (Volts AC)
Maximum Run/Brake or Forward/Reverse Operations per Minute*
Ambient Temperature Range (°C / °F) 0 – 40 / 32 – 104
*Based on a one (1) second braking time.
TABLE 3 – INTERCONNECTING WIRE HARNESS
Replaces Table 3, on page 5 of the manual.
Wire Color Location on Drive Wire Termination
Red A1A
115 or 208/230
4
Orange A1B
White A2B
Gray INH1
White / Black INH2
Brown* CON2
*The brown wire has been added to CON2.
FIGURE 2 – REMOVAL OF DRIVE JUMPERS
Updated to show CON2.
Replaces Figure 2, on page 4 of the manual.
(A42049) – Rev. A00 – 5/3/2010
Continued on other side…
Page 1 of 2
“The Right Control for Your Application.”
12095 NW 39 Street, Coral Springs, FL 33065-2516
Telephone: 954-346-4900; Fax: 954-346-3377
www.kbelectronics.com
Installation and Operation Manual Supplement for Anti-Plug Reversing Module (APRM) (Part No. 9378)
FOR USE WITH MODEL KBPW-240D
…continued from other side.
FIGURE 5 – INTERNAL WIRING DIAGRAM
Updated to show the SMT PC board and include the brown wire on the Interconnecting Wire Harness.
Replaces page 6 of the manual.
KBPW-240D and APRM
Gray
White/Black
Red
Black
White
Orange
Black
White
Red
Brown
Yellow
(A42049) – Rev. A00 – 5/3/2010 Page 2 of 2
ANTI-PLUG REVERSING MODULE (APRM
®
-PC) WITH DYNAMIC BRAKING
KB PART NO. 9378
FOR USE WITH KBPC-240D SPEED CONTROL
INSTALLATION AND OPERATING INSTRUCTIONS
See Safety Warning on page 1
The information contained in this manual is intended to be accurate. However, the manufacturer retains the right to make changes in design which may not be included herin.
PATENTED
A COMPLETE LINE OF MOTOR DRIVES
© 1997 KB Electronics, Inc.
TABLE OF CONTENTS
Section
i.
Page
Safety Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
I.
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
II.
Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
III.
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
IV.
Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
V.
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
TABLES
1.
APRM
®
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.
General Performance Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.
APRM
®
to PC Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4.
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
FIGURES
1.
APRM
®
Mounted in the KBPC-240D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.
KBPC-240D Jumper Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.
Switch Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4.
Remote Relay Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
5.
Internal Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
6.
Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
7.
Mechanical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 ii
ANTI-PLUG REVERSING MODULE (APRM
®
-PC) WITH DYNAMIC BRAKING
KB PART NO. 9378
FOR USE WITH KBPC-240D SPEED CONTROL
INSTALLATION AND OPERATING INSTRUCTIONS
See Safety Warning on page 1
The information contained in this manual is intended to be accurate. However, the manufacturer retains the right to make changes in design which may not be included herin.
PATENTED
A COMPLETE LINE OF MOTOR DRIVES
© 1997 KB Electronics, Inc.
TABLE OF CONTENTS
Section Page
i.
Safety Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
I.
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
II.
Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
III.
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
IV.
Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
V.
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.
APRM
®
TABLES
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.
General Performance Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.
APRM
®
to PC Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4.
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.
APRM
®
FIGURES
Mounted in the KBPC-240D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.
KBPC-240D Jumper Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.
Switch Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4.
Remote Relay Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
5.
Internal Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
6.
Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
7.
Mechanical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 ii
i. SAFETY WARNING! — PLEASE READ CAREFULLY
This product should be installed and serviced by a qualified technician, electrician or electrical maintenance person familiar with its operation and the hazards involved. Proper installation, which includes wiring, mounting in proper enclosure, fusing or other overcurrent protection and grounding, can reduce the chance of electric shocks, fires or explosions in this product or products used with this product, such as electric motors, switches, coils, solenoids and/or relays. Eye protection must be worn and insulated adjustment tools must be used when working with control under power. This product is constructed of materials (plastics, metals, carbon, silicon, etc.) which may be a potential hazard. Proper shielding, grounding and filtering of this product can reduce the emission of radio frequency interference (RFI) which may adversely affect sensitive electronic equipment. If information is required on this product, contact our factory. It is the responsibility of the equipment manufacturer and individual installer to supply this safety warning to the ultimate user of this product. (SW effective 11/92)
This control contains Start/Stop and Inhibit circuits that can be used to start and stop the control. However, these circuits are never to be used as safety disconnects since they are not fail-safe. Use only the AC line for this purpose.
The input circuits of this control (potentiometer, Start/Stop, Inhibit) are not isolated from AC line. Be sure to follow all instructions
carefully. Fire and/or electrocution can result due to improper use of this product.
This product complies with all CE directives pertinent at the time of manufacture. Contact factory for detailed installation instructions and Declaration of Conformity.
1
I.
OPERATION.
The APRM
®
-PC provides anti-plug instant reverse and solid state dynamic braking. It has been specifically designed for installation into the KBPC-240D speed control. The patented circuitry senses armature voltage and permits armature switching to take place only when current levels are near zero.
This eliminates contact arcing normally associated with relay reversing circuits.
TABLE 1 – APRM
Switch Position
Forward (FWD)
Brake (BRK)
Reverse (REV)
®
OPERATION
Switch Connection
S1, S2
None (Center off)*
S2, S3
Output Polarity
A1 A2
+
0
-
-
0
+
Braking is achieved via an electronic circuit utilizing an SCR and brake resistor. An LED indicates when the APRM
®
is in the brake mode. Operation is made via a SPDT switch with center off.
*Note: If no connection is made to S1, S2 and S3, the APRM ® mode which will rapidly stop the motor.
is in the brake
The unit installs easily into the inside cover of the KBPC control. Wiring is made via quick-connect terminals.
II.
SET UP.
Be sure the Jumpers J1 and J2 on the APRM
®
are both set to the proper AC line input voltage, 115 or 230VAC. Note: This should be the same setting as the Jumpers J2A and J2B are set for on the KBPC main board which should correspond to the correct AC line input voltage. Refer to the KBPC-240D Installation and Operating Instruction Manual for complete information.
TABLE 2 – GENERAL PERFORMANCE SPECIFICATIONS
Input AC line voltage – 50/60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115/230
Maximum number of run/brake or forward/reverse operations per minute* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Ambient temperature range (°C). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 – 50
*Based on a one (1) minute braking time.
2
i. SAFETY WARNING! — PLEASE READ CAREFULLY
This product should be installed and serviced by a qualified technician, electrician or electrical maintenance person familiar with its operation and the hazards involved. Proper installation, which includes wiring, mounting in proper enclosure, fusing or other overcurrent protection and grounding, can reduce the chance of electric shocks, fires or explosions in this product or products used with this product, such as electric motors, switches, coils, solenoids and/or relays. Eye protection must be worn and insulated adjustment tools must be used when working with control under power. This product is constructed of materials (plastics, metals, carbon, silicon, etc.) which may be a potential hazard. Proper shielding, grounding and filtering of this product can reduce the emission of radio frequency interference (RFI) which may adversely affect sensitive electronic equipment. If information is required on this product, contact our factory. It is the responsibility of the equipment manufacturer and individual installer to supply this safety warning to the ultimate user of this product. (SW effective 11/92)
This control contains Start/Stop and Inhibit circuits that can be used to start and stop the control. However, these circuits are never to be used as safety disconnects since they are not fail-safe. Use only the AC line for this purpose.
The input circuits of this control (potentiometer, Start/Stop, Inhibit) are not isolated from AC line. Be sure to follow all instructions
carefully. Fire and/or electrocution can result due to improper use of this product.
This product complies with all CE directives pertinent at the time of manufacture. Contact factory for detailed installation instructions and Declaration of Conformity.
1
I.
OPERATION.
The APRM
®
-PC provides anti-plug instant reverse and solid state dynamic braking. It has been specifically designed for installation into the KBPC-240D speed control. The patented circuitry senses armature voltage and permits armature switching to take place only when current levels are near zero.
This eliminates contact arcing normally associated with relay reversing circuits.
Braking is achieved via an electronic circuit utilizing an SCR and brake resistor. An LED indicates when the APRM
®
is in the brake mode. Operation is made via a SPDT switch with center off.
TABLE 1 – APRM
®
Switch Position
Forward (FWD)
Brake (BRK)
Reverse (REV)
OPERATION
Switch Connection
S1, S2
None (Center off)*
S2, S3
Output Polarity
A1 A2
+
0
-
-
0
+
*Note: If no connection is made to S1, S2 and S3, the APRM ® is in the brake mode which will rapidly stop the motor.
The unit installs easily into the inside cover of the KBPC control. Wiring is made via quick-connect terminals.
II.
SET UP.
Be sure the Jumpers J1 and J2 on the APRM
®
are both set to the proper AC line input voltage, 115 or 230VAC. Note: This should be the same setting as the Jumpers J2A and J2B are set for on the KBPC main board which should correspond to the correct AC line input voltage. Refer to the KBPC-240D Installation and Operating Instruction Manual for complete information.
TABLE 2 – GENERAL PERFORMANCE SPECIFICATIONS
Input AC line voltage – 50/60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115/230
Maximum number of run/brake or forward/reverse operations per minute* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Ambient temperature range (°C). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 – 50
*Based on a one (1) minute braking time.
2
III.
MOUNTING.
1. Mount the APRM
®
-PC on the 4 bosses located on the inside cover of the KBPC-240D using the four (4) # 6-32 screws provided.
Position the APRM so that the brake resistor is toward the bottom of the cover. Be sure not to trap any wires under the APRM mounting bracket. (See fig. 1.)
2. To mount the FWD-BRK-REV switch in the KBPC first remove the rubber plug in the FWD-BRK-REV position by unscrewing the retainer nut on the inside cover. (See fig. 3 p. 5.)
3. Install the FWD-BRK-REV switch assembly into the front cover making sure the key in the hole lines up with the keyway in the switch bushing. Be sure the hex nut supplied is installed at the base of the switch bushing before inserting switch into the KBPC cover.
4. Install the rubber switch boot with integral hex nut over switch lever.
Switch should be in the stop position to facilitate installation. Also, the switch bushing threads should protrude no more than .25"
(6.4mm) or no less than .10" (2.6mm) through the front cover for proper installation. Tighten the switch boot so that the bottom seals against the cover label. Do not overtighten.
FIG. 1 – APRM
®
MOUNTED IN THE KBPC-240D
3
5. FWD-BRK-REV switch remote mounted. It is possible to operate the control with a remote FWD-BRK-REV switch or with a remote relay. Carefully remove the three switch wires:
S1, S2, S3 from the APRM
®
. Wires may be extended for remote operation, but it is suggested that a shielded
® cable be used. (See table 1 APRM
Operation, p. 2.)
IV.
WIRING.
Do not wire control
with AC line connected.
1. Carefully remove from the KBPC main
PC board the 2 jumpers, J8A (connects A1A and A1B) and J8B (connects A2A and A2B). Note: Use long
nose pliers and rock terminal back and forth to facilitate removal. (See fig. 2.)
2. Install the wires from the APRM onto the following terminals on the KBPC main board. Refer to the internal wiring diagram provided. (See fig. 5, p. 6.)
4
FIG. 2 – KBPC-240D JUMPER REMOVAL
III.
MOUNTING.
1. Mount the APRM
®
-PC on the 4 bosses located on the inside cover of the KBPC-240D using the four (4) # 6-32 screws provided.
Position the APRM so that the brake resistor is toward the bottom of the cover. Be sure not to trap any wires under the APRM mounting bracket. (See fig. 1.)
2. To mount the FWD-BRK-REV switch in the KBPC first remove the rubber plug in the FWD-BRK-REV position by unscrewing the retainer nut on the inside cover. (See fig. 3 p. 5.)
3. Install the FWD-BRK-REV switch assembly into the front cover making sure the key in the hole lines up with the keyway in the switch bushing. Be sure the hex nut supplied is installed at the base of the switch bushing before inserting switch into the KBPC cover.
4. Install the rubber switch boot with integral hex nut over switch lever.
Switch should be in the stop position to facilitate installation. Also, the switch bushing threads should protrude no more than .25"
(6.4mm) or no less than .10" (2.6mm) through the front cover for proper installation. Tighten the switch boot so that the bottom seals against the cover label. Do not overtighten.
FIG. 1 – APRM
®
MOUNTED IN THE KBPC-240D
3
5. FWD-BRK-REV switch remote mounted. It is possible to operate the control with a remote FWD-BRK-REV switch or with a remote relay. Carefully remove the three switch wires:
S1, S2, S3 from the APRM
®
. Wires may be extended for remote operation, but it is suggested that a shielded
® cable be used. (See table 1 APRM
Operation, p. 2.)
IV.
WIRING.
Do not wire control
with AC line connected.
1. Carefully remove from the KBPC main
PC board the 2 jumpers, J8A (connects A1A and A1B) and J8B (connects A2A and A2B). Note: Use long
nose pliers and rock terminal back and forth to facilitate removal. (See fig. 2.)
2. Install the wires from the APRM onto the following terminals on the KBPC main board. Refer to the internal wiring diagram provided. (See fig. 5, p. 6.)
4
FIG. 2 – KBPC-240D JUMPER REMOVAL
FIG. 3 – SWITCH MOUNTING
RUBBER BOOT
COVER
HEX FACENUT
SWITCH BODY
FIG. 4 – REMOTE RELAY CONTACTS
TABLE 3 – APRM
®
TO PC CONNECTIONS
APRM
®
Wire Color
Terminal Position on KBPC
PC Board
Red
Orange
Black
White
A1A
A1B
A2A
A2B
Gray
White / Black
Yellow
I1
I2
F1*
*Note:
Newer models contain a connector on the yellow APRM
®
lead.
Observe correct polarity and insert the plug onto the mating connector just behind terminal block TB2. (See fig. 5, p. 6)
5
FIG. 5 – INTERNAL WIRING DIAGRAM
To avoid erratic operation do not bundle AC line and motor wires with reversing, potentiometer, voltage following, enable, inhibit or other signal wiring. Use shielded cables on all signal wiring over 12"
(30 cm) – Do not ground shield.
Note:
Reversing switch can be remotely mounted.
6
FIG. 3 – SWITCH MOUNTING
RUBBER BOOT
COVER
HEX FACENUT
SWITCH BODY
FIG. 4 – REMOTE RELAY CONTACTS
TABLE 3 – APRM
®
TO PC CONNECTIONS
APRM
®
Wire Color
Red
Terminal Position on KBPC
PC Board
A1A
Orange
Black
White
Gray
White / Black
Yellow
A1B
A2A
A2B
I1
I2
F1*
*Note:
Newer models contain a connector on the yellow APRM ® lead.
Observe correct polarity and insert the plug onto the mating connector just behind terminal block TB2. (See fig. 5, p. 6)
5
FIG. 5 – INTERNAL WIRING DIAGRAM
To avoid erratic operation do not bundle AC line and motor wires with reversing, potentiometer, voltage following, enable, inhibit or other signal wiring. Use shielded cables on all signal wiring over 12"
(30 cm) – Do not ground shield.
Note:
Reversing switch can be remotely mounted.
6
FIG. 7 – MECHANICAL SPECIFICATIONS
INCHES
[mm]
7
V – LIMITED WARRANTY
For a period of 18 months from date of original purchase, KB will repair or replace without charge devices which our examination proves to be defective in material or workmanship. This warranty is valid if the unit has not been tampered with by unauthorized persons, misused, abused, or improperly installed and has been used in accordance with the instructions and/or ratings supplied.
The foregoing is in lieu of any other warranty or guarantee, expressed or implied, and we are not responsible for any expense, including installation and removal, inconvenience, or consequential damage, including injury to any person, caused by items of our manufacture or sale. Some states do not allow certain exclusions or limitations found in this warranty so that they may not apply to you. In any event, KB's total liability, under all circumstances, shall not exceed the full purchase price of this unit. (rev
4/88)
KB ELECTRONICS, Inc.
12095 NW 39th Street, Coral Springs, FL 33065 • (954) 346-4900 • Fax (954) 346-3377
Outside Florida Call TOLL FREE (800) 221-6570 www.kbelectronics.com
(A40265) – Rev. B – 6/97
FIG. 7 – MECHANICAL SPECIFICATIONS
INCHES
[mm]
7
V – LIMITED WARRANTY
For a period of 18 months from date of original purchase, KB will repair or replace without charge devices which our examination proves to be defective in material or workmanship. This warranty is valid if the unit has not been tampered with by unauthorized persons, misused, abused, or improperly installed and has been used in accordance with the instructions and/or ratings supplied.
The foregoing is in lieu of any other warranty or guarantee, expressed or implied, and we are not responsible for any expense, including installation and removal, inconvenience, or consequential damage, including injury to any person, caused by items of our manufacture or sale. Some states do not allow certain exclusions or limitations found in this warranty so that they may not apply to you. In any event, KB's total liability, under all circumstances, shall not exceed the full purchase price of this unit. (rev
4/88)
KB ELECTRONICS, Inc.
12095 NW 39th Street, Coral Springs, FL 33065 • (954) 346-4900 • Fax (954) 346-3377
Outside Florida Call TOLL FREE (800) 221-6570 www.kbelectronics.com
(A40265) – Rev. B – 6/97
advertisement