pl_frico_accs_gb

pl_frico_accs_gb
Corinte
Corinte
Design air curtain for exclusive entrances, with intelligent control
•Horizontal mounting
- Recommended installation height 3 m*
- Lengths ADCS: 1,7 and 2,2 m
- Lengths ACCS: 1, 1,5, 2, 2,5 and 3 m
•Vertical mounting
- Recommended installation width 5 m*
(2 units), one on each side
- Lengths ADCS: 2,2 and 2,5 m
- Lengths ACCS: 2, 2,5 and 3 m
1Ambient, no heat
3Electrical heat ADCS: 15–22,5 kW
3Electrical heat ACCS: 9–23 kW
2Water heat WH, WL
R
Application
Corinte is intended for exclusive shop
entrances and other environments with high demands in
respect of design and soundlevel. Mounted with one unit on
either side of the opening, thus creating a classic symmetry,
the curtain effect and comfort is optimized.
The air curtain has many intelligent and energy saving
features which provide fully automatic protection for the
entrance, adaptable to each area of use.
Design
Corinte is a stylish and exclusive, stainless steel air curtain
for horizontal or vertical installation. Corinte is available in
two models; ADCS and ACCS that have varying dimensions
and performance. The product key offers many options for
the design and finish of both models.
Optimized airflow with
Thermozone technology.
Air velocity profile
Product specifications
m
m
0,1
ADCS
ACCS
9,6 m/s
m/s
11,0 m/s
m/s
0,5
6,5 m/s
m/s
6,1 m/s
m/s
1,0
4,8 m/s
m/s
4,6 m/s
m/s
1,5
4,1 m/s
m/s
3,9 m/s
m/s
2,0
3,7 m/s
m/s
3,6 m/s
m/s
2,5
3,4 m/s
m/s
3,3 m/s
m/s
3,0
3,1 m/s
m/s
3,0 m/s
m/s
• Prepared for the SIRe control system whose preprogrammed default settings and many features make it
easy to install and use the air curtain. Read more about
the SIRe controls package in the "Controls" section.
• Customised production based on the product key.
• Available for horizontal or vertical mounting.
• For vertical mounting, electricity and/or water may be
connected from above or below.
• Available in polished, mirror-polished or brushed
stainless steel. Colour intake and outlet grille: black,
RAL 9005.
Measurements according to ISO 27327-1. Average
values for products in the series.
2013-05-19
*) Recommended installation height and width varies depending on the relevant premises.
Corinte ACCS
ACCS
•Horizontal mounting
- Recommended installation height 3 m*
- Lengths: 1, 1,5, 2, 2,5 and 3 m
•Vertical mounting
- Recommended installation width 5 m*
(2 units), one on each side
- Lengths: 2, 2,5 and 3 m
3Electrical heat: 8–23 kW
2Water heat WH, WL
Corinte is available in two versions; ADCS and ACCS. Read more about ADCS in the beginning of this section.
*) Recommended installation height and width varies depending on the relevant premises.
Corinte ACCS
Technical specifications
3Electrical heat - ACCS E
Type
Outout
steps
[kW]
[m3/h]
ACCS10E08*¹
2,7/5,4/8,1
950/1900
∆t*4
Airflow*2
Voltage
motor
[V]
Amperage
motor
[A]
Voltage [V]
Amperage [A]
(heat)
Length
[°C]
Sound
level*3
[dB(A)]
[mm]
[kg]
25/13
44/61
230V~
2,2
400V3~/11,7
1000
50
Weight
ACCS15E12*¹
3,9/7,8/11,7
1350/2600
26/13
45/62
230V~
2,9
400V3~/16,9
1500
65
ACCS20E16
5,4/10,8/16,2
1980/3800
24/13
47/64
230V~
4,3
400V3~/23,4
2000
95
ACCS25E20
6,6/13,2/19,8
2340/4500
25/13
48/65
230V~
5,1
400V3~/28,6
2500
110
ACCS30E23
7,8/15,6/23,4
2660/5100
26/14
48/65
230V~
5,8
400V3~/33,8
3000
130
2Water heat - ACCS WH, coil for high temperature water (580 °C)
Output*5
V*8
H*7
[kW]
[kW]
[m3/h]
H*7
[°C]
ACCS10WH*¹
11,1
950/1900
23/17
-
Airflow*2
∆t*4,5
V*8
[°C]
Type
-
Water volume
H*7
V*8
[l]
[l]
Sound
level*3
[dB(A)]
Voltage
motor
[V]
Amperage Length
motor
[A]
[mm]
Weight
2,0
44/61
230V~
2,1
50
-
1000
[kg]
ACCS15WH*¹
15,1
-
1350/2600
23/17
-
3,2
-
45/62
230V~
2,9
1500
65
ACCS20WH
22,3
30,3
1980/3800
23/17
30/24
4,3
3,0
47/64
230V~
4,3
2000
95
ACCS25WH
27,1
33,4
2340/4500
23/18
28/22
5,4
3,0
48/65
230V~
5,0
2500
110
ACCS30WH
35,2
51,9
2660/5100
26/21
38/30
6,6
5,6
48/65
230V~
5,7
3000
130
Water volume
H*7
V*8
[l]
[l]
Sound
level*3
[dB(A)]
Voltage
motor
[V]
Amperage Length
motor
[A]
[mm]
Weight
1,1
44/61
230V~
2,1
50
2Water heat - ACCS WL, coil for low water temperature (480 °C)
Type
ACCS10WL*¹
[m /h]
H*7
[°C]
9,0
950/1900
18/14
-
Airflow*2
∆t*4,6
V*8
[°C]
Output*6
V*8
H*7
[kW]
[kW]
3
-
-
1000
[kg]
ACCS15WL*¹
16,8
-
1350/2600
24/19
-
1,9
-
45/62
230V~
2,9
1500
65
ACCS20WL
23,5
23,1
1980/3800
23/18
22/18
2,5
4,4
47/64
230V~
4,3
2000
95
ACCS25WL
29,3
25,8
2340/4500
24/19
21/17
3,3
4,4
48/65
230V~
5,0
2500
110
ACCS30WL
34,6
31,1
2660/5100
25/20
22/18
3,9
5,6
48/65
230V~
5,7
3000
130
*1) Available only for horizontal mounting.
*2) Lowest/highest airflow of totally 5 fan steps.
*3) Conditions: Distance to the unit 5 metres. Directional factor: 2. Equivalent absorption area: 200 m². At lowest/highest airflow.
*4) ∆t = temperature rise of passing air at maximum heat output and lowest/highest airflow.
*5) Applicable at water temperature 80/60 °C, air temperature, in +18 °C.
*6) Applicable at water temperature 60/40 °C, air temperature, in +18 °C.
*7) Horizontal mounting
*8) Vertical mounting
CE compliant.
Protection class: IP20.
Product key
Type - Unit shape - Connections position - Finish / Material
Example: ACCS25WL - VL - A - P
Connections position
Horizontal
Typ
See technical specifications
Unit shape
HL (Horizontal, connections to the left),
HR (Horizontal, connections to the right),
VL (Vertical Left) or VR (Vertical Right)
seen from inside
Connections
position
Finish /
material
Vertical
A or B, see figure.
P = Polished stainless steel
B = Brushed stainless steel
MP = Mirror polished stainless steel
Design and specifications are subject to change without notice.