Viking E-40, C-200, C-2000A, SLP-1, K-1900-5, DLE-200B, C-1000B, TBB-1, Hot-Line Dialer, PNL40, VE-3x5, 9331, Surge Protector Technical Practice
Below you will find brief information for E-40 E-40, C-200 C-200, C-2000A C-2000A, K-1900-5 K-1900-5. The E-40 Entry Phone is designed to be telephone line powered for two-way handsfree communication and features a compact size that allows it to be mounted in a standard single gang electrical box. The E-40 can be purchased separately and is available in five standard finishes to match your door hardware. The C-200 Entry Phone Controller is designed to control one E-40 on a single phone line. The C-2000A Entry Phone Controller is designed to control 1 to 4 E-40’s and door/gate control on a single phone line. The K-1900-5 Auto Dialer is designed to provide automatic speed dialing on telephone lines or analog PABX/KSU station ports.
Advertisement
Advertisement
TECHNICAL
P r r a c t t i i c e
2 1
S T
T
E L E C O M
S
O L U T I I O N S F O R T H E
C
E N T U R Y
Compact and Attractive
Entry Phones
October 12, 2006
Compact Entry Phones Available in Five Attractive Finishes
E-40-SS
“Brushed Stainless Steel”
(similar to brushed nickel)
E-40-BN
“Oil Rubbed Bronze”
(satin dark brown powder paint with fine copper metallic)
E-40-PB
“Polished Brass”
(with clear gloss powder paint to prevent tarnishing)
E-40-WH
“Satin White”
(satin white powder paint)
E-40-BK
“Satin Black”
(fine texture satin black powder paint)
The E-40 Series Entry phones are compact, weather and vandal resistant, telephone line powered speaker phones designed to provide two-way handsfree communication. The E-40's compact size allows it to be mounted in a standard single gang electrical box. The E-40 is available in five different attractive finishes to match your door hardware, light fixtures, etc. Replacement
E-40 faceplates (PNL40) can be purchased separately and are available in all five standard finishes.
The E-40 entry phones can share a single phone line with house or small business telephones when used with a Viking model
C-200 or C-2000A Entry Phone controller. The E-40 entry phones can also be connected to an unused analog station port (programmed for ring down) on a phone system or connected directly to a telephone line when used with a Viking model K-1900-5 auto dialer. The E-40 features microphone and speaker volume controls, selectable auto answer for monitoring and intelligent call progress detection for automatic hang-up when the call is completed. For extreme outdoor environments or corrosive atmospheres, the E-40 Series is available with Enhanced Weather Protection (EWP).
Need More Information on EWP?
?
Call (715) 386-4345 and select 859.
F e a t t u r r e s
• Compact size: Front panel is the size of a typical single gang midsize wall plate
• Mounting: Flush mounts in any single gang (1.7” deep minimum) electrical box or surface mounts in a Viking model VE-3x5 (not included)
• Available in 5 standard faceplate finishes: Brushed Stainless Steel,
Oil Rubbed Bronze, Polished Brass, Satin Black and Satin White
• PNL-40 faceplates: Replacement faceplates with matching screws available in all five standard finishes
• Weather Resistant Features: Mylar speaker, faceplate gasket, mic and speaker gasket, internally sealed (IP67) push button switch, self draining mic mount and UV stable weather resistant powder coating (excluding E-40-SS Stainless Steel faceplate)
• Optional Enhanced Weather Protection (EWP) available
• Vandal Resistant Features: 16 gauge polished brass or 18 gauge stainless steel faceplate, stainless steel push button, stainless steel speaker screen, scratch resistant powder coating, hex drive mounting screws
• Telephone line powered
• Microphone and speaker volume controls
• Programmable Intelligent call progress detection for automatic hang-up on CPC, silence, busy signal, or time out
• Selectable auto answer feature for monitoring
• Programmable VOX (mic/speaker) switching speed i i n f f o @ v i i k i i n g e l l e c t t r r o n i i c s .
.
c o m h t t t t p : : / / / / w w w .
.
v i i k i i n g e l l e c t t r r o n i i c s .
.
c o m
A p p l l i i c a t t i i o n s
• Door or gate communication, business delivery entrances
• Use with a Viking C-200 to control one E-40 on a single phone line
• Use with a Viking C-2000A to control 1 to 4 E-40’s and door/gate control on a single phone line
• Provide unique front and back door chimes and paging when used with a Viking SLP-1 and C-2000A
• Residential, commercial and industrial door security
• Use with a Viking K-1900-5 for automatic speed dialing on telephone lines or analog PABX/KSU station ports
• Use on any analog PABX station port with programmable ringdown capability
S p e c i i f f i i c a t t i i
P h o n e .
.
.
.
.
.
7 1 5 .
.
3 8 6 .
.
8 8 6 1 o n s
Power: Telephone line powered (18 VDC/20mA minimum)
Dimensions: Faceplate: 123.8mm x 79.4mm x 4.6mm (4.875” x 3.125” x
0.18”), Phone: 71mm x 46mm x 42mm (2.8” x 1.8” x 1.65”)
Shipping Weight: 0.45 kg (1.0 lbs)
Operating Temperature: -32° C to 54° C (-25° F to 130° F)
Humidity: Standard model: 5% to 95% non-condensing humidity, EWP model: up to 100% humidity
Speaker Volume: Approximately 62db maximum @ 1m
Ring Voltage: 25V AC RMS minimum (for auto answer)
CPC Disconnect Time: 300ms minimum
REN: 0.8A
Connections: (2) gel-filled butt connectors
IF YOU HAVE A PROBLEM WITH A VIKING PRODUCT, PLEASE CONTACT: VIKING TECHNICAL SUPPORT AT (715) 386-8666
Our Technical Support Department is available for assistance Monday 8am - 4pm and Tuesday through Friday 8am - 5pm central time. So that we can give you better service, before you call please:
1. Know the model number, the serial number and what software version you have (see serial label).
2. Have your Technical Practice in front of you.
3. It is best if you are on site.
RETURNING PRODUCT FOR REPAIR
The following procedure is for equipment that needs repair:
1. Customer must contact Viking's Technical Support Department at 715-386-8666 to obtain a Return Authorization (RA) number. The customer MUST have a complete description of the problem, with all pertinent information regarding the defect, such as options set, conditions, symptoms, methods to duplicate problem, frequency of failure, etc.
2. Packing: Return equipment in original box or in proper packing so that damage will not occur while in transit. Static sensitive equipment such as a circuit board should be in an anti-static bag, sandwiched between foam and individually boxed. All equipment should be wrapped to avoid packing material lodging in or sticking to the equipment. Include
ALL parts of the equipment. C.O.D. or freight collect shipments cannot be accepted. Ship cartons prepaid to:
Viking Electronics, 1531 Industrial Street, Hudson, WI 54016
3. Return shipping address: Be sure to include your return shipping address inside the box. We cannot ship to a PO Box.
4. RA number on carton: In large printing, write the R.A. number on the outside of each carton being returned.
RETURNING PRODUCT FOR EXCHANGE
The following procedure is for equipment that has failed out-of-box (within 10 days of purchase):
1. Customer must contact Viking’s Technical Support at 715-386-8666 to determine possible causes for the problem. The customer MUST be able to step through recommended tests for diagnosis.
2. If the Technical Support Product Specialist determines that the equipment is defective based on the customer's input and troubleshooting, a Return Authorization (R.A.) number will be issued. This number is valid for fourteen (14) calendar days from the date of issue.
3. After obtaining the R.A. number, return the approved equipment to your distributor, referencing the R.A. number. Your distributor will then replace the product over the counter at no charge. The distributor will then return the product to
Viking using the same R.A. number.
4. The distributor will NOT exchange this product without first obtaining the R.A. number from you. If you haven't followed the steps listed in 1, 2 and 3, be aware that you will have to pay a restocking charge.
LIMITED WARRANTY
Viking warrants its products to be free from defects in the workmanship or materials, under normal use and service, for a period of one year from the date of purchase from any authorized Viking distributor or 18 months from the date manufactured, which ever is greater. If at any time during the warranty period, the product is deemed defective or malfunctions, return the product to Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI., 54016. Customer must contact Viking's
Technical Support Department at 715-386-8666 to obtain a Return Authorization (R.A.) number.
This warranty does not cover any damage to the product due to lightning, over voltage, under voltage, accident, misuse, abuse, negligence or any damage caused by use of the product by the purchaser or others.
NO OTHER WARRANTIES. VIKING MAKES NO WARRANTIES RELATING TO ITS PRODUCTS OTHER THAN AS DESCRIBED ABOVE AND DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTIES OR MERCHANTABILITY OR FIT-
NESS FOR ANY PARTICULAR PURPOSE.
EXCLUSION OF CONSEQUENTIAL DAMAGES. VIKING SHALL NOT, UNDER ANY CIRCUMSTANCES, BE LIABLE TO PURCHASER, OR ANY OTHER PARTY, FOR CONSEQUENTIAL, INCIDENTAL, SPECIAL OR EXEMPLARY DAM-
AGES ARISING OUT OF OR RELATED TO THE SALE OR USE OF THE PRODUCT SOLD HEREUNDER.
EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY. WHETHER IN AN ACTION BASED ON CONTRACT, TORT (INCLUDING NEGLIGENCE OR STRICT LIABILITY) OR ANY OTHER LEGAL THEORY, ANY LIABILITY OF VIKING SHALL
BE LIMITED TO REPAIR OR REPLACEMENT OF THE PRODUCT, OR AT VIKING'S OPTION, REFUND OF THE PURCHASE PRICE AS THE EXCLUSIVE REMEDY AND ANY LIABILITY OF VIKING SHALL BE SO LIMITED.
IT IS EXPRESSLY UNDERSTOOD AND AGREED THAT EACH AND EVERY PROVISION OF THIS AGREEMENT WHICH PROVIDES FOR DISCLAIMER OF WARRANTIES, EXCLUSION OF CONSEQUENTIAL DAMAGES, AND EXCLU-
SIVE REMEDY AND LIMITATION OF LIABILITY, ARE SEVERABLE FROM ANY OTHER PROVISION AND EACH PROVISION IS A SEPARABLE AND INDEPENDENT ELEMENT OF RISK ALLOCATION AND IS INTENDED TO BE ENFORCED
AS SUCH.
FCC REQUIREMENTS
This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA. Inside the front panel of this equipment is a label that contains, among other information, a product identifier in the format US:AAAEQ##TXXXX.
If requested, this number must be provided to the telephone company.
The REN is used to determine the number of devices that may be connected to a telephone line. Excessive REN's on a telephone line may result in the devices not ringing in response to an incoming call. In most but not all areas, the sum of the REN's should not exceed five (5.0) To be certain of the number of devices that may be connected to a line, as determined by the total REN's, contact the local telephone company. For products approved after July 23, 2001, the REN for this product is part of the product identifier that has the format US:AAAEQ##TXXXX. The digits represented by ## are the
REN without a decimal point (e.g., 03 is a REN of 0.3). For earlier products, the REN is separately shown on the label.
The plug used to connect this equipment to the premises wiring and telephone network must comply with the applicable
FCC Part 68 rules and requirements adopted by the ACTA. If your home has specially wired alarm equipment connected to the telephone line, ensure the installation of this E-40 does not disable your alarm equipment. If you have questions about what will disable alarm equipment, consult your telephone company or a qualified installer.
If the E-40 causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice isn't practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary.
The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make the necessary modifications to maintain uninterrupted service.
If trouble is experienced with the E-40, for repair or warranty information, please contact:
Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI 54016 (715) 386-8666
If the equipment is causing harm to the telephone network, the telephone company may request that you disconnect the equipment until the problem is resolved.
Connection to Party Line Service is subject to State Tariffs. Contact the state public utility commission, public service commission or corporation commission for information.
WHEN PROGRAMMING EMERGENCY NUMBERS AND (OR) MAKING TEST CALLS TO EMERGENCY NUMBERS:
Remain on the line and briefly explain to the dispatcher the reason for the call. Perform such activities in the off-peak hours, such as early morning or late evenings.
It is recommended that the customer install an AC surge arrester in the AC outlet to which this device is connected. This is to avoid damaging the equipment caused by local lightning strikes and other electrical surges.
PART 15 LIMITATIONS
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
I I n s t t a l l l l a t t i i o n
The E-40 is designed to be flush mounted into a standard single gang Rough-In box with a min depth of 1.7”. The E-40 can also be surface mounted in a standard single gang wet location/weather proof box with a min depth of 1.7” (not included).
A. New Construction Flush Mounting
Step 1. Front of box should stick out approximately ½" from front surface of wall stud (this may vary depending on the walls sheathing and siding thickness). Caution: Rough-In box must be mounted LEVEL and must NOT stick out beyond the front surface of siding.
Step 2. To maintain a vapor barrier on outside wall applications, caulk around the box, filling any gaps between the box and the rough opening.
Apply caulk to any holes in the box around wires, etc.
Step 3. When installing siding cut a hole just large enough for the Rough-In box opening. Caution: Too large of a hole can cause plate misalignment and compromise the gasket seal. Note: When mounting to 4 inch or less horizontal lap siding, the unit can be mounted horizontally flush against siding or a siding mounting block can be used (recommended with vinyl siding). Contact siding installer for the correct mounting block.
B. Old Work / Remodel Flush Mounting
(Using an Allied Molded 9331 Rough-In Box)
Step 1. Make sure mounting location is free of wall studs, wires, etc.
Step 2. Place Rough-In box LEVEL against siding. Trace outline of box onto siding. Note: When mounting to 4 inch or less horizontal lap siding, the unit can be mounted horizontally flush against siding or a siding mounting block can be used. Contact your siding Installer for the correct mounting block part number. Note: A siding mounting block is recommended when mounting to vinyl siding.
Step 3. Cut a hole through the siding and wall sheathing just large enough for the rough-in box. Caution: Too large of a hole can cause plate misalignment and compromise the gasket seal.
Step 4. The front surface of the Rough-In box can be mounted flush against wood siding or can be recessed and mounted flush against wall sheathing when mounting on aluminum, steel or vinyl siding.
Step 5. When mounting to 5/8 inch thick or less wall sheathing the two attached screws with wing brackets can be used to secure the rough-in box. When mounting to surfaces thicker than 5/8 inch, four standard flat head dry wall screws can be used to secure the Rough-In box through its mounting ears.
Step 6. To maintain a vapor barrier on outside wall applications, caulk around the box, filling any gaps between the box and the rough opening. Apply caulk to any holes in the box around wires, etc.
C. Surface Mounting
A Viking model VE-3x5 can be used to surface mount an E-40 to a wall or post. Drill a small wire exit hole in wall. Pull wire through and seal hole around wire with putty or caulking. Route wire into the VE-3x5 box, securely screw it to wall or post and seal hole in box around wire with putty or caulking. Note: Conduit may also be used when surface mounting wire, but should not enter through the top of the VE-3x5. When routing wiring from above, a drip loop is required.
D. Mounting the Faceplate
After the Rough-In box or VE-3x5 is securely mounted, caulking between the box and rough opening is completed (if required), and wires are connected, remove paper liner from face plate gasket and place it on back side of face plate aligning with push button hole. Push the 1-1/4" 6-32 screws through faceplate holes and small holes in gasket, the faceplate gasket should retain the screws.
Position Circuit board mounting plate over screws. Align screws with single gang box bosses and tighten face plate until gasket is fully collapsed and the push button is protruding through the clearance hole in the face plate. Included 1/4" thick gasket will provide an adequate seal for most siding surfaces; however for rough surfaces (ie: brick, stucco, etc.) additional caulking may be required.
3.125"
3.17"
1.8" Optional
Mounting Ears
Optional Wing
Brackets
4.92"
-OR-
1.7"
Deep
Min.
(2) Gel-Filled
Butt Connectors
(included)
Red
Green
4.875"
Condensation
Drain Hole
Conduit Knockout
Optional VE-3x5 Surface Mount
Box with Black Satin Powder
Paint Finish (not included)
"Old Work" Rough-In Box
(Allied Molded 9331 box shown, not included)
(4) Optional Dry
Wall Screws
(not included)
E. Wiring the E-40
Circuit Board
Mounting Plate
(included)
1/4" Thick Foam
Faceplate Gasket
(included)
Facplate
(included)
(2) 6-32 x 1.25" Long
5/64" Hexdrive Flathead
Screws (included)
(Ring connector included)
Rear View of the
E-40 Circuit Board
Mounting Plate
Viking C-200 Single Entry
Phone Controller (not included)
VIKING
©
MODEL C-200
VIKING
ELECTRONICS
HUDSON, WI 54016
SINGLE ENTRY PHONE
CONTROLLER
Viking C-2000A 1-4 Entry Phone
Controller (not included)
VIKING
©
MODEL C-2000A
*** Optional Viking
K-1900-5 Dialer
(not included)
VIKING
ELECTRONICS
HUDSON, WI 54016
**** C.O. Line or Analog
PABX/KSU Station
(programmed for ringdown)
** Earth
Ground
(optional)
* Gel-Filled Butt
Connectors
(included) E-40 is not polarity sensitive
ON
1 2 3
1 2 3 4 5 6 7 8 9 10
EARTH
GND
C.O. LINE
INPUT
OUT TO
PHONES
ENTRY
PHONE
N.O. COM N.C.
AUX CONTACTS
ADVANCED DOOR/GATE AND
ENTRY PHONE CONTROLLER
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
VIKING
©
Programmable
Tone Dialer
MODEL: K-1900-5
Quick Programming Guide
2. Answer phone. Enter
∗
& security code.
(Factory set to 845464) Write your
security code below:
3. Enter your spped dial number & #00.
Note: For additional programming see
K-1900-5 Technical Practice.
Viking Electronics, Inc.
Hudson, WI 54016
LINE IN PHONE
Viking DLE-200B
Two Way Ringdown
Circuit (not included)
VIKING
©
DLE-200B
RES
RINGDOWN
1 2
BUSY
Red
(Ring)
Green
(Tip)
To C.O. Line or
PABX/KSU station
-or-
!
IMPORTANT: Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet and the telephone line. It is recommended that a surge protector be installed to protect against such surges.
Contact Panamax at (800) 472-5555 or Electronic Specialists Inc. at (800) 225-4876.
To dedicated phone, unused trunk/ line input of a phone system, or
Viking C-1000B Doorbox Controller
* Note: The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire with a maximum insulation of 0.082 inches. Do not strip wires prior to terminating.
** Note: To increase surge protection, loosen the PCB mounting screw labeled (as shown above) and fasten a wire with ring terminal (included) from the mounting screw to
Earth Ground (grounding rod, water pipe, etc.) After fastening ring treminal to PCB mounting screw, bend terminal up to avoid interference with single gang box.
*** Note: Talk battery must be a minimum of 28V DC when using the speaker phone with a Viking Hot-Line Dialer. For more information, retrieve Fax Back Documents 833.
**** Note: When installing a line powered phone on a low voltage and/or low loop current phone system extension, a Viking
TBB-1 Talk Battery Booster may be required.
?
Need More Information on the PS-2R?
Call (715) 386-4345 and select 512.
P r r o g r r a m m i i n g
A. Adjusting Speaker Volume
The speaker volume pot can be adjusted to increase or decrease the speaker volume to the level desired.
B. Adjusting the Microphone Volume
In certain noisy locations (background traffic, machinery or wind), the microphone volume may need to be decreased. A symptom of this is oneway talk path, in which the distant party cannot be heard over the speaker. A microphone volume pot is provided for increasing or decreasing the microphone volume. Note: If the microphone volume is set too high or too low, one-way talk path may occur.
Microphone
Volume
(see section B)
DIP
Switches
ON ON
OFF
1 2 3
Speaker
Volume
(see section A)
Rear View of the
E-40 Circuit Board
Mounting Plate
Note: Pots and DIP switches are shown in factory default settings.
C. DIP Switch Programming
DIP
Switch
Position Description
1. Auto Answer Feature ON/OFF (DIP Switch 1)
DIP switch 1 is for turning the Auto Answer feature ON and OFF. The E-40 is factory set to auto answer when an inbound call is detected.
1
1
ON
OFF
Auto-Answer ON *
Auto-Answer OFF
2. Dial Tone Detection ON/OFF (DIP Switch 2)
With DIP switch 2 in the ON position, if the E-40 detects more than 5 seconds of continued dial tone, the unit will automatically disconnect. If the E-40 is installed on a continuously noisy line, it may detect the noise as dial tone and automatically disconnect. If this happens, turn the dial tone detection (DIP switch 2) OFF.
2
2
3
3
ON
OFF
ON
OFF
Dial Tone Detection ON *
Dial Tone Detection OFF
Programming Mode
Normal Operation Mode *
3. Programming Mode ON/OFF (DIP Switch 3)
* Note: These are the factory settings.
With DIP switch 3 in the OFF position, the E-40 is in the “Normal Operation Mode” (factory setting). By placing DIP switch 3 in the ON position, the E-40’s programming mode is enabled. The programming mode is used for adjusting the Call Length Time Out, Silence Time for automatic disconnect and the Talk/Listen delay (VOX switching speed). These features are set from the factory and normally do not need adjustment. If adjustment is necessary, see Programming sections D - I.
D. Accessing the Programming Mode
The E-40 can be programmed from any Touch Tone phone using a telephone line, Viking model C-200 or C-2000A Entry Phone
Controller, analog PABX/KSU station or a Viking model DLE-200B Line Simulator.
Step 1. Move DIP switch 1 to the ON position (sets unit to answer incoming calls - see section C).
Step 2. Move DIP switch 3 to ON (incoming calls automatically enter the programming mode - see section C).
Step 3. From a Touch Tone phone call the line attached to the E-40.
Step 4. When the E-40 answers, 2 beeps will be heard and you will automatically enter the programming mode.
Step 5. When finished programming, enter “0000” to exit programming and move DIP switch 3 back to OFF (see section C).
E. Quick Programming Features
Call length time out (1-9 minutes), blank = disabled (factory set to 11111 = 5 minutes) ..................................
Silence time out for disconnect (10-90 seconds), blank = disabled (factory set to 1111 = 40 secs) ................
Talk/listen delay (VOX switching speed) 0.1 - 0.9 seconds (factory set to 111 = 0.3 secs) .............................
Forced hang-up command (used to exit programming and hang up the E-40) ..............................................
Select
Feature
0
00
000
0000
Wait for
Beep(s) beep beep beep
3 beeps
Enter
Time Value
111...
111...
111...
Wait for
2 Beeps beep beep beep beep beep beep
F. Programming Beeps
See Table A below
If a valid “Feature” is entered, a single beep will be heard. If an invalid “Feature” (five or more zeros) is entered, 3 beeps will be heard and the E-40 will hang up. If a valid “Time” is entered 2 beeps will be heard. If an invalid “Time” is entered, 3 beeps will be heard and you will have 20 seconds to enter the next valid “Feature”. Note: After entering a “Feature” and hearing the first confir- mation beep, you will have 3 seconds to enter a time value. If not entered, a blank time value will be entered in that “Feature”.
G. Call Length Time Out
This feature selects the maximum length of time that calls can be connected.
Programmable in increments of 1 minute up to a maximum of 9 minutes.
Programming nothing in the time value location will disable the call length time out. With the call length disabled, the E-40 phone must rely on CPC, busy, silence or return dial tone to hang-up. Use the chart at the right. * Note: The factory default is 5 minutes.
H. Silence Time Out
This feature selects the length of time that calls will remain connected without voice activity. Programmable in increments of 10 seconds up to a maximum of
90 seconds. To disable the silence time out, program nothing in the time value location. Use the chart at the right. * Note: The factory default is 40 seconds.
Time
Value
Blank
1
11
111
1111
11111
111111
1111111
11111111
111111111
Call Length
Time Out
Disabled
1 min
2 min
3 min
4 min
5 min*
6 min
7 min
8 min
9 min
Table A
Silence
Time Out
Disabled
10 sec
20 sec
30 sec
40 sec*
50 sec
60 sec
70 sec
80 sec
90 sec
Talk/Listen
Delay
N/A
.1 sec
.2 sec
.3 sec*
.4 sec
.5 sec
.6 sec
.7 sec
.8 sec
.9 sec
I. Talk/Listen Delay (VOX Switching Speed)
This feature selects switching time between talk and listen modes (VOX switching time). Use the chart above.
* Note: The factory default is .3 seconds.
O p e r r a t t i i o n
When the push button is pressed, the E-40 phone goes off-hook, much like a standard speaker phone. In the event that the line is busy, the E-40 will hang-up. The E-40 will also automatically hang up on CPC, silence, busy signal, return to dial tone or time out. If programmed to auto-answer (DIP switch
1 ON), the E-40 will also answer any incoming call.
P r r o d u c t t S u p p o r r t t L i i n e .
.
.
.
.
.
7 1 5 .
.
3 8 6 .
.
8 6 6 6 F a x B a c k L i i n e .
.
.
.
.
.
7 1 5 .
.
3 8 6 .
.
4 3 4 5
Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes.
Fax Back Doc 187 Printed in the U.S.A.
ZF302200 Rev B

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Telephone Line Powered
- Compact Size
- Weather and Vandal Resistant
- Two-Way Handsfree Communication
- Available in Five Finishes
- Programmable Auto Answer
- Microphone and Speaker Volume Controls
- Intelligent Call Progress Detection
- Optional Enhanced Weather Protection