East Coast Datacom SME-530 Synchronous Modem Eliminator Operations Manual
Below you will find brief information for Synchronous Modem Eliminator SME-530. The SME-530 allows two RS-530 DTE devices to communicate within proximity of each other. The SME-530 transmits data bi-directionally at data rates up to 2.048Mbps between DTE devices. All clocking and signal crossover are provided within the SME-530. The unit is equipped with two female DB-25-P connectors.
Advertisement
Advertisement
TABLE OF CONTENTS
CHAPTER 1 - INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page 1
1.1 FUNCTIONAL DESCRIPTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page 1
CHAPTER 2 - BASIC OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page 2
2.1 FRONT PANEL INDICATORS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page 2
2.2 REAR PANEL CONNECTORS AND FUSES . . . . . . . . . . . . . . . . . . . . . . . . .
Page 2
2.3 CLOCKING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page 2
2.4 ELECTRICAL INTERFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page 2
2.5 CTS FOLLOWS RTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page 2
2.5.1 RTS TO CTS DELAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page 2
CHAPTER 3 - INSTALLATION Page 3
3.1 VOLTAGE SELECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page 3
3.2 VOLTAGE SELECTION FUSES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page 3
3.3 POWER CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page 3
3.4 DEFAULT CONFIGURATION SWITCH SETTINGS. . . . . . . . . . . . . . . . . . . .
Page 4
3.5 TERMINAL (DTE) CONNECTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page 4
3.6 INTERNAL SWITCH SETTINGS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page 4
3.6.1 DIP SWITCHES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page 4
3.6.2 SWITCH FUNCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page 4
4.0 - APPENDIX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page 7
4.1 RS-530 INTERFACE CHART . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page 7
OPERATIONS MANUAL
RS-530 SYNCHRONOUS MODEM ELIMINATOR
MODEL: SME-530
14 June, 2000
FOR TECHNICAL SUPPORT CALL:
East Coast Datacom, Inc.
TEL: (800) 240-7948 or (321) 637-9922
FAX: (321) 637-9980
Email: [email protected]
Web Site: www.ecdata.com
Manufactured By
:
East Coast Datacom, Inc.
PT # 123020-B
SAFETY WARNING
Always observe standard safety precautions during installation, operation and maintenance of this product. To avoid the possibility of electrical shock, be sure to disconnect the power cord from the power source before you remove the IEC power fuses or perform any repairs.
PROPRIETARY NOTICE
The information contained herein is proprietary to East Coast Datacom, Inc. Any reproduction or redistribution of this publication, in whole or in part, is expressly prohibited unless written authorization is provided by East Coast Datacom, Inc.
WARRANTY NOTICE
WARRANTIES: East Coast Datacom, Inc. (hereafter referred to as E.C.D.) warrants that its equipment is free from any defects in materials and workmanship. The warranty period shall be three (3) years from the date of shipment. E.C.D.'s sole obligation under its warranty is limited to the repair or replacement of defective equipment, provided it is returned to E.C.D., transportation prepaid, within a reasonable period. This warranty will not extend to equipment subjected to accident, misuse, alterations or repair not made by
E.C.D. or authorized by E.C.D. in writing.
PUBLICATION NOTICE
This manual has been compiled and checked for accuracy. The information in this manual does not constitute a warranty of performance. E.C.D. reserves the right to revise this publication and make changes from time to time in the content thereof. E.C.D. assumes no liability for losses incurred as a result of out-of-date or incorrect information contained in this manual.
East Coast Datacom, Inc. SME-530 OPERATIONS MANUAL
CHAPTER 1 - INTRODUCTION
1.1 FUNCTIONAL DESCRIPTION
The SME-530 allows two RS-530 DTE devices to communicate within proximity of each other. The SME-530 transmits data bi-directionally at data rates up to 2.048Mbps between
DTE devices. All clocking and signal crossover are provided within the SME-530. The unit is equiped with two female DB-25-P connectors.
The SME-530 is an excellent choice for interconnecting your LAN or mainframe equipment.
Substantial cost savings are derived by eliminating the need for Modems or Line Drivers.
Installation is fast and simple by setting the internal switches for Clocking and RTS to CTS delay. The SME-530 has status LED's for each attached DTE device which allows the user to visually confirm the presence of control signals.
The SME-530 utilizes state of the art digital CMOS technology to provide a feature filled product at a very affordable price. Our Field Programmable Gate Array (FPGA) design has allowed us to offer this product with a wide selection of user Baud Rates. This design approach has also eliminated clock jitter for high speed 2.048Mbps transmissions.
The SME-530 is housed in a sturdy metal enclosure and operates on 110/220VAC.
Typical MTBF figures are in excess of 100,000 hours of operation.
RS-530 CABLES
MAINFRAME
OR ROUTER
SME-530
SPEEDS TO 2.048Mbps
TYPICAL APPLICATION
Figure 1.1
Page 1
MAINFRAME
OR ROUTER
East Coast Datacom, Inc. SME-530 OPERATIONS MANUAL
CHAPTER 2 - BASIC OPERATION
2.1 FRONT PANEL INDICATORS
A Green LED marked PWR illuminates when AC Power has been applied. Two adjacent sets of Green LEDs illuminate in union with individual DTE port control signal activity.
2.2 REAR PANEL CONNECTORS AND FUSES
Located on the back or rear of the product you will find an IEC Power receptacle. The supplied power cord plugs into this receptacle. This receptacle also contains a fuse drawer. Two (2) fuses are located in this compartment. For 110 VAC +/- 10% operation the unit is equipped with slow blow 160ma Fuses, Part # 714000. For 220 VAC +/- 10% operation the unit is equipped with slow blow 80ma Fuses, Part # 714001. Additionally,
DB-25 female connectors, marked PORT A and PORT B.
2.3 CLOCKING
The SME-530 provides an internal baud rate generator with user defined clock rates from
19.2Kbps up to 2.048Kbps.
2.4 ELECTRICAL INTERFACE
The SME-530 is EIA RS-530-C compliant utilizing the international EIA specification. The unit is equiped with female DB-25-P connectors. Refer to the interface chart in the
Appendix for detailed interface information.
2.5 CLEAR TO SEND (CTS) FOLLOWS REQUEST TO SEND (RTS)
The SME-530 has individual settings for each user port so that CTS follows RTS.
2.5.1 REQUEST TO SEND (RTS) DELAY
The SME-530 has individual user port settings for RTS delay. Options of no delay, 6ms,
12ms and 24ms are provided.
Page 2
East Coast Datacom, Inc. SME-530 OPERATIONS MANUAL
CHAPTER 3 - INSTALLATION
CAUTION: Disconnect Power Before Servicing
ATTENTION: Couper Le Courant Avant l' Entretien
VORSICHT: Befor Deckung Abnehmen Mach Strom Zu
3.1 VOLTAGE SELECTION
It is very important to check that the unit is set to the correct voltage setting for your application before applying AC power. Located on the rear of the unit you will find a rotary
110/220 VAC switch. Using a coin or small screwdriver, gently turn the switch to the appropriate power position as required for your installation (110 or 220 VAC).
3.2 VOLTAGE SELECTION FUSES
Located on the back or rear of the product you will find an IEC Power receptacle. This receptacle contains a fuse drawer. Two (2) fuses are located in this compartment. For
110 VAC +/- 10% operation the unit is equipped with slow blow 5 x 20mm 160ma Fuses,
E.C.D. Part # 714000. For 220 VAC +/- 10% operation the unit is equipped with slow blow 5 x 20mm 80ma Fuses, E.C.D. Part # 714001. Spare fuses may be purchased by calling East Coast Datacom or by calling the fuse manufacturer: Little Fuse at (312)
824-3024 or Shurter, Inc. at (707) 778-6311
Little Fuse Part #'s are: 160ma = 218.160 and 80ma = 218.080
Shurter, Inc. Part #'s are: 160ma = 034.3109 and 80ma = 034.3106
3.3 POWER CONNECTION
Before connecting the SME-530 to an AC power source the top cover should be installed with the supplied #4-40 screws. AC power is supplied to the unit through a 2.3m (6.6 ft) cord terminated by a grounded 3-prong plug. Select an appropriate location accessible to and within four to five feet of an AC outlet. The AC Power source MUST be grounded or the units Warranty will be void.
Power Connection
Figure 3-1
3.4 DEFAULT CONFIGURATION SWITCH SETTINGS
Page 3
East Coast Datacom, Inc. SME-530 OPERATIONS MANUAL
The SME-530 is configured prior to shipping with the Dip Switches set as follows:
1) Clock Rate - 19.2kbps
2) Port A / Port B RTS - Follows CTS
3) Port A / Port B CTS delay - No Delay
4) Chassis to Signal GND - Not Connected
If your system application requires one or more of the default setting to be changed, it will be necessary to remove the top cover. Disconnect the AC Power source before servicing the unit. Removal of the top cover is accomplished by using a small Philips screwdriver and removing the four outside screws. After setting the switches, replace the top cover before applying AC power.
3.5 TERMINAL (DTE) CONNECTION
Before applying AC Power to the unit, the DCE and DTE cabling should be connected.
Straight through Male to Male DB-25 shielded cables, no longer than 50 feet in any direction should be used. If your cables are not shielded or over 50 feet long, transmission errors may occur.
3.6 INTERNAL SWITCH SETTINGS
3.6.1 DIP SWITCHES
The SME-530 has two Dip Switch's that are accessible by removing the Top Cover.
Located safely inside the unit, you will find a 4 position Dip Switch marked S1 and a 10
position Dip Switch marked S2. To change the settings, you may use your finger tip or a small nonconductive instrument. It is recommended NOT to use metal objects to push on the Dip Switches, as you may slip and damage a component trace.
3.6.2 SWITCH FUNCTIONS
The following two pages provide a chart for the SME-530 switches and the function of each switch. Please refer to this chart for all settings.
Page 4
East Coast Datacom, Inc. SME-530 OPERATIONS MANUAL
SME-530 STRAPPING CHART
BAUD RATE SELECTION
SME-530 STRAPPING CHART
Switch
S4 S3 S2 S1
S1
Internal
Baud Rate Generator off off off off - Clock = off off off on - Clock = off off on off - Clock = off off on on - Clock = off on off off - Clock = off on off on - Clock = off on on off - Clock = off on on on - Clock = on off off off - Clock = on off off on - Clock = on off on off - Clock = on off on on - Clock = on on off off - Clock = on on off on - Clock = on on on off - Clock = on on on on - Clock =
BRG= Baud Rate Generator
19.2 KHz
28.8 KHz
38.4 KHz
48 KHz
56 KHz
57.6 KHz
64 KHz
72 KHz
128 KHz
192 KHz
256 KHz
384 KHz
512 KHz
1.536 MHz
1.544 MHz
2.048 MHz
Page 5
East Coast Datacom, Inc. SME-530 OPERATIONS MANUAL
Switch
S10 S9 S8 S7 S6
S2
S5 S4
Not Port B Port B Port B Not Port A used CTS Delay CTS Clock Used CTS Delay
S3 S2 S1
Port A Port A
CTS Clock
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
V off off
|
|
|
|
|
V off on
|
|
V off on off - Port A clocks from BRG on - Port A clocks from Port A external
- CTS follows RTS according to S4, S3
- CTS is forced on
- no delay from RTS
- 6 mS delay from RTS
|
V on on off on
- 12 mS delay from RTS
- 24 mS delay from RTS off - Port B clocks from BRG on - Port B clocks from Port A external
|
V
|
|
|
|
|
V
V off - CTS follows RTS according to S9, S8 on - CTS is forced on off off - no delay from RTS off on - 6 mS delay from RTS on off - 12 mS delay from RTS on on - 24 mS delay from RTS
Port A straps
Jumper Pos 1
- Port A DSR follows Port B DTR
J1
Pos 2 - Port A DSR forced on
Jumper Pos 1
J2
Pos 2
- Port A DCD enabled follows Port B RTS
- Port A DCD forced on
Port B Straps
Jumper Pos 1
- Port B DSR follows Port A DTR
J3
Pos 2 - Port B DSR forced on
Jumper Pos 1
J4
Pos 2
- Port B DCD enabled follows Port A RTS
- Port B DCD forced on
General
Jumper Pos 1
J5
Pos 2
- Signal Ground isolated from Frame Ground
- Signal Ground connected to Frame Ground
POWER
ENTRY
MODULE
KEEP OUT
XFMR
DB-25 CONNECTOR
PORT A
J5
J1 J2
DB-25 CONNECTOR
PORT B
J3 J4
CONTROL JUMPERS ARE SHOWN IN
POSITION 1(UP) POSITION, THIS IS
THE FACTORY DEFAULT. TO FORCE
A SIGNAL, MOVE TO POSITION 2 (DOWN)
DISCONNECT POWER
BEFORE SERVICING
S2
S1
PORT "A" INDICATORS PORT "B" INDICATORS
Page 6
East Coast Datacom, Inc. SME-530 OPERATIONS MANUAL
4.0 - APPENDIX
4.1 RS-530 INTERFACE CHART
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Pin No
1
2
3
4
5
6
7
8
9
Signal Description
Shield
Transmit Data (A)
Receive Data (A)
Request to Send (A)
Clear to Send (A)
DCE Ready (A)
Signal Ground
Received Line Signal Detector (A)
Receiver Signal Element Timing (B)
Received Line Signal Detector (B)
External Transmit Signal Element Timing (B)
Transmit Signal Element Timing (B)
Clear To Send (B)
Transmitted Data (B)
Transmit Signal Element Timing (A)
Received Data (B)
Receiver Signal Element Timing (A)
Local Loopback
Request To Send (B)
DTE Ready (A)
Remote Loopback
DCE Ready (B)
DTE Ready (B)
External Transmit Signal Element Timing (A)
Test Mode
Return
Return
Return
Return
Return
DCE
Return
DCE
DTE
Return
DTE
DTE
Return
Return
DTE
DCE
SOURCE
Common
DTE
DCE
DTE
DCE
DCE
Common
DCE
Return
Page 7
NOTES:
East Coast Datacom, Inc. SME-530 OPERATIONS MANUAL
Page 8
5.0 - TECHNICAL SPECIFICATIONS
Application
Interconnection of two RS-530 DTE (Terminal) devices located within proximity of each other
Weight
2 pounds (0.914Kg)
Capacity
Two (2) RS-530 DTE's
Warranty
Three Years, Return To Factory
Interface
RS-530 using EIA specification
ORDERING INFORMATION
Model: SME-530
Description: Synchronous RS-530 Modem
Eliminator
Data Rates
19.2Kps to 2.048Mbps
Channel Interface
Two Female DB-25 Connectors
INCLUDED WITH EACH UNIT:
1) Operations Manual
2) U.S.A. Grounded Power Cord, Part # 713015
3) Optional Power Cords
A) United Kingdom, Part # 713016
B) Continental Europe, Part # 713017
C) Other: Specify Country on Purchase Order
Surge Protection
Main power supply
OPTIONAL ACCESSORIES
1) Spare Data Center Fuses
A) 160ma Fuse, Qty (2) Part # 714000
B) 80ma Fuse, Qty (2) Part # 714001
Power Source
100-120 to 200-220VAC @10%, 50/60Hz,
0.16/0.08A, external 110/220 volt select switch,
IEC Power Inlet, (2) 5mm Fuses
For further detailed technical information on this product, contact East Coast Datacom Technical
Assistance toll free at (800) 240-7948
OTHER EAST COAST DATACOM PRODUCTS
Environmental
Operating Temperature
....
32º to 122º F (0º to 50º C)
Relative Humidity
.............
5 to 95%
Non-Condensing
Altitude
............................
0 to 10,000 feet
MODEM AND PORT SHARING DEVICES
INTERFACE CONVERTERS
SIGNAL SPLITTERS
LINE DRIVERS
Dimensions
Height
.......
1.75 inches (4.44 cm)
Width
........
7.90 inches (20.07 cm)
Length
.......
9.00 inches (22.86 cm)
Advertisement
Key Features
- Transmits data bi-directionally at data rates up to 2.048Mbps
- Provides internal baud rate generator with user defined clock rates from 19.2Kbps up to 2.048Kbps
- Allows two RS-530 DTE devices to communicate within proximity of each other
- Provides individual settings for each user port so that CTS follows RTS
- Has individual user port settings for RTS delay
- Housed in a sturdy metal enclosure
- Operates on 110/220VAC