QUICK REFERENCE GUIDE Version: 6‐3‐2010 CONTROL MODULE KEYPAD
The Sentinel Control Module has a 24‐button keypad for use as the programming interface: This keypad includes numeric buttons 1 – 9 and 0 used for numeric data entry. Also used in programming and operations are: ON/YES & OFF/NO Keys Used for manual operations as well as entering ON / OFF or YES / NO in programming. ESC (Escape) Key Used for exiting menus or Edit Mode and returning to normal operations (default screen) ENTER Key Used for functions like entering a selected submenu or saving information. Arrow (Navigation) Keys CLUSTER / SCHEDULE SELECT Key PROGRAM SELECT Key Used for navigating in Menus, Submenus, and Edit Modes, as well an incrementing values in programming. This button is used for selecting Clusters (groups of 4 programs) or schedules (run days) when programming. This button is used for selecting the Program (1‐4) associated with a Clusters when programming. Also included are four F‐keys are provided on the control module keypad to conveniently perform the following functions: F1 Key ‐ Displays the time. F2 Key F3 Key ‐ Displays the status of the automatic programs. ‐ Shuts down anything that is running (panic button). IMPORTANT: The F3 key is not functional while in the Edit mode. F4 Key ‐ Displays context sensitive help while in the Edit mode. SENTINEL SATELLITE QUICK REFERENCE Page 2 /8 CONTROL MODULE DISPLAY
The Sentinel Controller has a two‐line LCD for display of information. When you first walk up to your Sentinel controller, the display should be in its standard mode showing current time, day, week (of schedule), actual flow (if anything running) and expected flow. This display should look something like the following: Default Display Upper Line Lower Line Actual Flow – 00000 (0 GPM) Time – 07:18 P (7:18 PM) Expected Flow – 00000 (0 GPM) Day – MO (Monday) Flow Status – No current flow Week (of schedule) – W1 (Week 1) Sensor – No current sensor indication indicator Alarm Status – A (Alarm Exists) Remote – L (Locked) The standard indicators in the display are as follows: TIME HH:MM Hours : Minutes (12‐hour format) A or P AM or PM DAY SU, MO, Two‐letter Designation of Day of Week TU, WE, TH, FR, SA, or SU WEEK W1 to W6 Week 1 (one) of Schedule up to Week 6 (six) of Schedule SENSOR 1 Sensor Activated ‐ Switch sensor is in alternate of its Normal condition. E.g. If Normally Open, then 1 = Sensor Closed. O Dry contact (switch) sensor is Open C Dry contact (switch) sensor is Closed REMOTE L Field Unit is in remote “Locked” mode. Hand held radio will not activate watering functions within this unit. A Field Unit is programmed for “All Call” handheld radio operation. Controller will respond to any and all handheld commands transmitted. S Field Unit is programmed for “Secure” handheld radio operation. Controller will respond only to handheld commands addressed to its unit code. ACTUAL FLOW 00000 5‐digit numeric indicator of current flow through connected flow sensor EXPECTED 00000 5‐digit numeric indicator of expected flow based on current stations FLOW operating and their expected flows. FLOW STATUS + Actual > Expected (Overflow) ‐‐ Actual < Expected (Underflow) :) Actual = Expected (Flow is happy) A Flow Alarm Exists ALARM STATUS A Alarm Exists – Blank Otherwise SENTINEL SATELLITE QUICK REFERENCE Page 3 /8 PROGRAMMING OVERVIEW
The Sentinel Controller is programmed by navigating through a Main Menu which includes seven options: Operations, Utility, Alarms, Flow, Schedule Data, Program Data, and Zone/ET Data. Each of these Main Menu options has a Submenu for entering and changing data. This structure is detailed below as well as being shown on the Program Instructions Card on the control module itself. MAIN MENU SUBMENUS •
•
•
Manual Auto Slot / Station Rain Off Days •
•
•
All Manuals Off All Autos Off Station Days Off •
•
•
•
Time & Day Day Change Hour Unit Code Station Count •
•
•
Program Clear N/O Master Two‐Wire / Irritrol Mode •
•
•
•
Master Minimum Unexpected Flow Over Flows Over Currents •
•
•
•
Clear Flow Alarms Clear Fuse Alarms Clear Map Alarms Clear Power Fail •
•
•
•
K Factor Offset Factor Current Flow Expected Flows •
•
•
Maximum Flows Flow Processing Read Flow Totals •
•
•
Run Days Schedule Length Clear Schedule •
•
•
•
Start Times Slot‐Station‐Time Percent Scale Repeats •
•
•
•
Repeat Delay time Continuous Run Water Window Assigned Schedule •
•
•
•
Plant Factor Precipitation Rate Default ET Program ET Toggle •
•
•
Maximum ET Station Type Map Stations SENTINEL SATELLITE QUICK REFERENCE Page 4 /8 NAVIGATION
•
To enter the Main Menu from this default screen, you need to hit any of the arrow keys on the keypad: •
•
•
, , , or . This will bring up the OPERATIONS option of the Main menu. To navigate through the Main Menu, use the right or left arrow keys: or . To enter a submenu for any of the Main menu options, use the up or down arrow keys: When the desired submenu is reached, press the enter key submenu. or . to view or change data in the IMPORTANT: When entering data into one of the submenus, the controller is in the Edit Mode. The controller will not begin any scheduled operation until you have exited the Edit Mode. Programs that are running prior to entering the Edit Mode will continue running. Any time you enter or change any data, you must press the ENTER key to save the data. Otherwise, the newly entered data will not be saved. To exit the Edit Mode, press the ESC key (Escape Key) once or twice as necessary to return to normal mode (default) screen. If you forget to press the ESC key, the controller will automatically revert to normal mode after two minutes. SETTING CURRENT TIME & DATE
1. From the default screen (press ESC twice to reach screen if not in it), press the Right Arrow Key on the controller keypad until UTILITY is displayed in the screen. 2. Press the Down Arrow Key until Time & Day is displayed in the screen 3. Press the Enter Key to view the Time & Day entry screen. 4. Position the cursor using the Right and Left Arrow Keys under the value being edited and use the keypad to set the time, date, and week number. Enter the current time, date, an set as W1 (Week 1). 5. Press ENTER Key to Save. 6. Pres ESC Key twice to return to Default screen. SETTING CONTROLLER UNIT CODE
IMPORTANT: The unit code is required for Central Control operations. Even if most of the satellite programming will be from the central software, you need to set the Unit Code. All other controller settings can be made from the Sentinel Software. 1. From the default screen (press ESC twice to reach screen if not in it), press the Right Arrow Key on the controller keypad until UTILITY is displayed in the screen. 2. Press the Down Arrow Key until Unit Code is displayed in the screen 3. Press the Enter Key to view the Unit Code entry screen. 4. Position the cursor using the Right and Left Arrow Keys under the digit being edited. Use the numeric keys on the keypad to enter digits. Enter a unique three‐digit Unit Code from 001‐999. 5. Press ENTER Key to Save Unit code. 6. Pres ESC Key twice to return to Default screen. SENTINEL SATELLITE QUICK REFERENCE Page 5 /8 MANUAL [SINGLE] STATION OPERATION
1. From the default screen (press ESC twice to reach screen if not in it), press the Right Arrow Key on the controller keypad until OPERATIONS is displayed in the screen. 2. Press the Down Arrow Key until Manual is displayed in the screen 3. Press the Enter Key to view the Manual Operations screen. 4. Press the Up Arrow Key to display the Station that you want. 5. Press the ON/YES Key to turn the displayed station on. 6. The default manual time is 30 minutes. If a different time is desired: Press the Right Arrow Key and enter the desired runtime using the numeric keypad. 7. Press ENTER Key to set new manual runtime. 8. To turn the station off, press the OFF/NO Key. 9. Press the ESC Key twice to return to Default screen. MANUAL PROGRAM OPERATION
Note: Sentinel Controllers have 16 Programs. These Programs are divided into 4 Groups
(Clusters A, B, C, & D) with 4 Programs, each. Program Designation follows the following
Format: Cluster X, Program Y = CXPY where X can be A, B, C, or D and Y can be 1-4.
CAP1 CAP2 CAP3 CAP4 CBP1 CBP2 CBP3 CBP4 CCP1 CCP2 CCP3 CCP4 CDP1 CDP2 CDP3 CDP4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1. From the default screen (press ESC twice to reach screen if not in it), press the Right Arrow Key on the controller keypad until OPERATIONS is displayed in the screen. 2. Press the Down Arrow Key until Auto Slot / Station is displayed in the screen. 3. Press the Enter Key to view the Auto Slot / Station Screen. 4. Press the CLUSTER / SCHEDULE SELECT Key and the PROGRAM SELECT Key to choose the Cluster and Program # to start. 5. Press the ON/YES Key to turn the displayed program on. Note: The program will start at the top of the next minute. 6. To turn the program off, press the OFF/NO Key. 7. Press the ESC Key twice to return to Default screen. SENTINEL SATELLITE QUICK REFERENCE Page 6 /8 CHANGE WATERING (RUN) DAYS
Note: Before Editing Run Days, verify in controller default screen what current week of 6‐week schedule is. If current week is Week 6 (W6), then Week 1 will be next week (looping 6‐Week Schedule). 1. From the default screen (press ESC twice to reach screen if not in it), press the Right Arrow Key on the controller keypad until SCHEDULE DATA is displayed in the screen. 2. Press the Down Arrow Key until Run Days is displayed in the screen. 3. Press the Enter Key to view the Run Days Edit Screen. 4. Press the Up Arrow Key to Select the Week (1‐6) you want to edit. 5. Press the Right Arrow Key so the cursor is on the Day. 6. Press the Up Arrow Key to Select the Day of The Week. 7. Use the ON / YES Key to make that day a watering Day or use the OFF/ NO Key to make that Day a non‐watering day. 8. Make desired changes for all 6 weeks of the schedule. 9. Press the ENTER Key to save changes. 10. Press the ESC Key twice to return to Default screen. CHANGE START TIMES
Note: Each of the 16 Programs can have up to 8 Start Times. 1. From the default screen (press ESC twice to reach screen if not in it), press the Right Arrow Key on the controller keypad until PROGRAM DATA is displayed in the screen. 2. Press the Down Arrow Key until Start Times is displayed in the screen. 3. Press the Enter Key to view the Start Times Edit Screen. 4. Press the CLUSTER / SCHEDULE SELECT Key and the PROGRAM SELECT Key to choose the Cluster and Program # to edit. 5. Press the Up Arrow Key to Select the Start Time (ST 1‐8) to enter or edit. 6. Press the Right Arrow Key to move the Cursor to the Time. 7. Use the Numeric Keypad to enter the Start time and the Up or Down Arrow Key to select AM or PM. 8. Press the ENTER Key to save changes. 9. Press the ESC Key twice to return to Default screen. SENTINEL SATELLITE QUICK REFERENCE Page 7 /8 CHANGE STATION RUNTIMES
Note: Each of the 16 Programs has 48 station positions called “Slots.” Each Slot can have a station and a runtime. 1. From the default screen (press ESC twice to reach screen if not in it), press the Right Arrow Key on the controller keypad until PROGRAM DATA is displayed in the screen. 2. Press the Down Arrow Key until Slot‐Stn‐Time is displayed in the screen. 3. Press the Enter Key to view the Slot Edit Screen. 4. Press the CLUSTER / SCHEDULE SELECT Key and the PROGRAM SELECT Key to choose the Cluster and Program # to edit. 5. Press the Up Arrow Key to Select the Slot to enter or edit. 6. Press the Right Arrow Key to move the Cursor to the Station. 7. Press the Up Arrow Key to Select the Station to add runtime for in that Slot.. 8. Press the Right Arrow Key to move the Cursor to the Runtime. 9. Use the Numeric Keypad to enter the station runtime (H:MM) 10. Press the ENTER Key to save changes. 11. Press the ESC Key twice to return to Default screen. RAIN OFF DAYS
1. From the default screen (press ESC twice to reach screen if not in it), press the Right Arrow Key on the controller keypad until OPERATIONS is displayed in the screen. 2. Press the Down Arrow Key until Rain Off Days is displayed in the screen. 3. Press the Enter Key to view the Rain off Days Edit Screen. 4. Press the CLUSTER / SCHEDULE SELECT Key and the PROGRAM SELECT Key to choose the Cluster and Program # to turn off. 5. Use the Numeric Keypad to enter the number of Rain Days that you want that program to be off for. Note: Today is Day 1, so if 1 day is entered, irrigation will be allowed to commence after midnight. 6. Press the ENTER Key to save changes. 7. Press the ESC Key twice to return to Default screen. For Additional Information on Sentinel Controller Programming, refer to the Sentinel Controller User Guide. SENTINEL SATELLITE QUICK REFERENCE Page 8 /8 