Mendota DXV-35 DT3 LX gas fireplace Installation & Operating Instructions
Below you will find brief information for gas fireplace DXV-35 DT3 - LX. This gas fireplace provides a natural gas fireplace that incorporates the traditional aesthetics of fireplace fire viewing with the controllability and fuel efficiency of a home gas furnace. It is a true heating appliance with a state-of-the-art co-axial direct vent, sealed combustion system. The Mendota System efficiently heats and re-circulates room air. The gas fireplace provides an elegant, highly efficient direct heat source for your home. This fireplace model provides a large degree of flexibility for many venting configurations. It comes factory equipped for venting off the top but can be converted to use L.P.
Advertisement
Advertisement
MENDOTA GAS DIRECT VENT FIREPLACE
with
Premium Texture Fiber Logs Combustion System
Model DXV-35 DT3 - LX
INSTALLATION & OPERATING INSTRUCTIONS
NO. LX-1111
WARNING
If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
CAUTION: Keep gasoline and other liquids having flammable vapors away.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
ATTENTION. Garder l’essence ou autres liquides produisant des vapeurs inflammables loin del’appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucun interrupteur; ne pas vous servir des téléphones se trouvant dans le bâtiment.
• Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur, appelez le service des incendies.
WARNING
Do NOT use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control, which has been under water.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
N’utilisez pas cet appareil s’il a été plongé dans l’eau, même partiellement. Faites inspecter l’appareil par un technicien qualifiéet remplacez toute partie du système de contrôle et toute commande qui ont été plongés dans l’eau.
AVERTISSEMENT : Une installation, un réglage, une modification, une réparation ou un entretien mal effectué peut causer des dommages matériels ou des blessures. Voir la notice de l'utilisateur quiaccompgne l’appareil. Pour de l’aide oueds renseignements supplémentaires, consultez un installateur, un technicien agréé ou le fournisseur de gaz.
FOR YOUR SAFETY READ BEFORE LIGHTING
POUR PLUS DE SÉCURITÉ, LIRE AVANTD'ALLUMER
WARNING
Do not operate this appliance with the glass removed, cracked or broken. A licensed or qualified person should do replacement of glass.
This appliance must be i nstalled in accordance with local codes, if any; if none, follow the National Fuel
Gas Code, ANSI Z223.1, or Canadian Installation
Codes, CAN/CGA-B149. Gas and Propane Installation Code, CSA B149.1
Attention. Ne pas utiliser l’appareil si le panneau frontal en verre n’est pas enplace, est craqué ou brisé.
Confiez leremplacement du panneau à untechnicien agréé.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence dételés règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas
Code ou CAN/CGA-B149 en vigueur.
This appliance is only for use with the type(s) of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. See owner's manual for details.
This appliance is supplied with a conversion kit.
Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
In the Commonwealth of Massachusetts:
• Installation must be performed by a licensed plumber or gas fitter;
• A CO detector shall be installed in the room where the appliance is installed.
Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avecd'autres gaz sauf si une trousse deconversion certifiée est fournie.
Attention. Au moment de l’entretiennes commandes, étiquetez tous les fil savant de les débrancher. Des erreurs decâblage peuvent entraîner unfonctionnement inadéquat etdangereux.
CAUTION
THESE INSTRUCTIONS ARE TO REMAIN WITH
THE HOMEOWNER.
DXV35 DT3 FEATURES - QUICK REFERENCE INFORMATION
EXTERNAL DIMENSIONS: 35-7/8” Wide X 31-1/2” High X 15-1/2” Deep
MINIMUM FRAMING DIMENSIONS: 37-1/8” WIDE x 31-1/2” HIGH X 16” DEEP
GLASS SIZE: NeoCeram Glass with non-reflective coating. Visible Glass measures 456 in 2 . Actual Glass size is 580 in 2 .
MANTEL ALLOWANCE: 8” Deep Mantel at 14” Above Top Convection Opening
VENT SYSTEM ALLOWANCE: Top Vent Only. 12” Vertical Minimum with 6” max horizontal. 55 feet Vertical Maximum.
4” exhaust and 6-5/8” combustion air intake coaxial vent pipe required. 12’ maximum horizontal run allowed with 4’ minimum vertical starter section.
VENT DAMPER ADJUSTMENT AVAILABLE: There is one exhaust vent damper included in this unit and located in the top convection chamber at the center.
CONTROLS: IPI Electronic Ignition System with AC Primary Power and DC Backup Power. Accent light and Blowers operate on AC Power only. Thermostatic Remote Control Transmitter with Smart Thermostat Mode.
BLOWER SYSTEM: 210 CFM Dual Blower System. 120VAC, 2Amps. Dedicated Hot Power only. No switches, Fan Speed
Controls or Light Dimmers are allowed in same circuit.
Accent Light System: Accent Light System Included. Light can be turned on or off or dimmed using dimmer mounted behind lower grill. Accent Light can also be turned on or off using Remote Control Transmitter.
BURNER SYSTEM: Dual 304 Stainless Steel Tubular burners.
BURNER AIR SHUTTER SYSTEMS: Externally controllable Rear Burner air shutter and Internal rotary Front Burner air shutter.
LOG SET: 9-piece, Premium Definition Log Set with Extreme glow and realism ember bed.
REFRACTORY PANELS: High Detail Red Clinker Fiber Brick Panels included. Brick Panels required for operation.
NATURAL GAS INFORMATION: Factory equipped for Natural Gas. 4.5”WC Minimum inlet pressure required. For NG applications, Front Burner Orifice Size is #49 and the Rear Burner Orifice Size is #44.
LPG INFORMATION: LP conversion kit #HA-30-00507 is required. 12”WC Minimum inlet pressure required. For the
DXV35 DT3 LPG application, both front are rear burner orifices are to be drill size 3/64”. For higher altitude, adjustment to orifice size may be necessary.
INITIAL STARTUP ADVICE
PAINT CURING CYCLE RECOMMENDATION: It is recommended that you run this Fireplace on maximum flame height, for 3 cycles of 2 hours ON and 2 hours OFF, initially, to cure the paint.
BLOWER BREAK-IN PERIOD: The integrated blowers in this Insert may exhibit some bearing noise and electrical static noise during the first few days of operation. This is normal during the break-in period. It is recommended that following the
Paint Curing Cycle, the blowers be run at their maximum speed for two 3-hour periods. The burner flames must be on during these cycles. The blowers in a few fireplaces may take longer to break-in and may require additional operation time before all extraneous noise is eliminated. Please allow adequate operational time for the blowers to break-in before you contact your dealer for service.
2
TABLE OF CONTENTS
FOR YOUR SAFETY READ BEFORE LIGHTING ................................................................................................................. 1
DXV35 DT3 FEATURES - QUICK REFERENCE INFORMATION ..................................................................................... 2
INITIAL STARTUP ADVICE ................................................................................................................................................ 2
TABLE OF CONTENTS .......................................................................................................................................................... 3
SPECIFICATIONS .................................................................................................................................................................. 5
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION .................................................................................. 5
Building Permit and Installation Inspection Approval Requirements ................................................................................... 5
Specific Requirements for the Common Wealth of Massachusetts ........................................................................................ 6
SAFETY AND WARNING INFORMATION ............................................................................................................................. 7
CONGRATULATIONS ............................................................................................................................................................ 8
GENERAL INFORMATION ..................................................................................................................................................... 9
VENT OPTIONS DISCUSSION ............................................................................................................................................ 10
GAS SUPPLY REQUIREMENTS .......................................................................................................................................... 11
GAS PRESSURE REQUIREMENTS .................................................................................................................................... 12
EXTERIOR VENT LOCATIONS AND RESTRICTIONS ....................................................................................................... 13
GENERAL FLUE VENTING INSTRUCTIONS ...................................................................................................................... 14
VENT COMPONENTS "TWIST-LOCK" CONNECTION PROCEDURE ........................................................................... 14
GENERAL INSTALLATION INSTRUCTIONS ...................................................................................................................... 15
SPECIFICATIONS & CLEARANCES .................................................................................................................................... 16
TOP FLUE VENTING COMPONENTS ................................................................................................................................. 17
FLUE VENTING ALLOWANCE CHART ............................................................................................................................... 18
L.P. GAS MINIMUM HEIGHT HORIZONTAL TERMINATION ............................................................................................. 19
MINIMUM RISE THROUGH-THE-WALL VENTING: ............................................................................................................ 20
VENTING COMPONENTS LIST ........................................................................................................................................... 21
ELEVATED VERTICAL RISE THROUGH-THE-WALL VENTING ....................................................................................... 22
VERTICAL THROUGH-THE-ROOF VENTING .................................................................................................................... 23
DOOR REMOVAL AND REPLACEMENT ............................................................................................................................ 24
DXV-35 DT3 DEEP TIMBER LOG SET INSTALLATION INSTRUCTIONS ......................................................................... 26
INSTALLATION CHECK OFF LIST ...................................................................................................................................... 37
LIGHTING CHECK OFF LIST ............................................................................................................................................... 37
BEFORE YOU BEGIN ........................................................................................................................................................... 38
REMOTE TRANSMITTER OPERATING INSTRUCTIONS .................................................................................................. 40
MANUAL BYPASS OF THE REMOTE SYSTEM .................................................................................................................. 41
TEMPERATURE INDICATOR ( o F or o C) .............................................................................................................................. 41
KEY LOCK FUNCTION ......................................................................................................................................................... 41
LOW BATTERY POWER DETECTION ................................................................................................................................ 41
OPERATING DURING POWER OUTAGES ........................................................................................................................ 41
“FIRST TIME” PILOT LIGHTING INSTRUCTIONS .............................................................................................................. 42
3
INITIALIZING THE REMOTE CONTROL SYSTEM .......................................................................................................... 42
Backup Batteries ................................................................................................................................................................... 43
OPERATING DURING POWER OUTAGES ..................................................................................................................... 43
BLOWER OPERATION AND WIRING ............................................................................................................................. 44
TROUBLE SHOOTING MENDOTA GAS DXV FIREPLACE ................................................................................................ 45
CUSTOMER INFORMATION AND TROUBLE-SHOOTING ................................................................................................ 46
MAINTENANCE .................................................................................................................................................................... 47
WIRING SCHEMATICS ........................................................................................................................................................ 48
NATURAL TO LP GAS CONVERSION INSTRUCTIONS ................................................................................................ 49
ORIFICE SIZES REQUIREMENT: .................................................................................................................................... 49
RECOMMENDED PROCEDURE TO CONVERT THIS FIREPLACE TO BURN LPG ..................................................... 49
INSTALLING THE LP PRESSURE REGULATOR ............................................................................................................ 52
LP GAS PRESSURE REQUIREMENTS ............................................................................................................................... 53
LPG PROPER INPUT RATES........................................................................................................................................... 53
LEAK TESTING REQUIREMENTS ................................................................................................................................... 53
PILOT FLAME AND MAIN BURNER RELATIONSHIP VERIFICATION ........................................................................... 53
PILOT FLAME LENGTH ADJUSTMENT .......................................................................................................................... 53
CHECKING FOR NORMAL BURNER (S) IGNITION CHARACTERISTICS .................................................................... 54
REPLACEMENT PARTS ...................................................................................................................................................... 55
MENDOTA DESIGNER FRONTS INSTALLATION INFORMATION .................................................................................... 56
RATING LABEL REPRESENTATION .................................................................................................................................. 58
MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM ................................................................... 60
MENDOTA EXTENDED LIFETIME PROTECTION AND LIMITED WARRANTY ................................................................ 62
4
SPECIFICATIONS
INPUT RATES (Btu/Hr)
NAT. GAS
LP GAS
MODEL DXV-35 DT3
High Fire - Adjustable to -
33,000
33,000
Low Fire
10,000
13,000
NOTE: LP CONVERSION KIT #HA-30-00501 MUST BE PURCHASED SEPARATELY TO BURN LPG.
MAIN ORIFICES… REAR BURNER : #44 NAT. GAS [3/64” L.P. GAS] – FRONT BURNER : #49 NAT. [3/64” LP]
OVERALL EFFICIENCY Exceeds D.O.E. Efficiency Requirements (A.F.U.E.) For Direct Vent Wall Heaters.
78.5% Steady State Efficiency
CO-AXIAL DIRECT VENT FLUE .... Top Vent: 4" Inner, 6 5/8" Outer
APPROVED VENT SYSTEMS: Amerivent, Duravent, Selkirk Metalbestos, Security Chimney and ICC
NET WEIGHT ................................... 185 POUNDS
SAFETY ........................................... AGA CERTIFIED PILOT GENERATOR, MILLIVOLT SYSTEM
ACTIVATED WITH REMOTE CONTROL.
GAS REQUIREMENTS .................... SUPPLY PRESSURE
NAT. GAS:
L.P. GAS:
: GAS INLET: 3/8" N.P.T.at Gas Valve Entry Point
7" W.C. (5" W.C. MIN., 11" W.C. MAX.)
12.0" W.C. (12" W.C. MIN., 14" W.C. MAX.)
ELECTRICAL REQUIREMENTS..... 115 VOLT, LESS THAN 2 amps, Un-switched direct power.
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION
Unit to floor
Vent to enclosed
Unit to enclosure sidewall
Vent to adjacent sidewall
0 in.
0.5 in.
1 in.
10 in.
Unit to enclosure sidewalls
Unit top to ceiling
Wall Pass-Through to framing 1 in.
Mantle above discharge air opening
0.5 in.
18 in.
14 in.
Certified under ANSI Z21.88 (2005) • CSA 2-33 (2005) “Vented Gas Fireplace Heaters" not for use with solid fuel.
Approved or bedroom installations and mobile homes. UL307B approved for "mobile homes, after first sale of home, not for recreational vehicles."
Gas appliances must be tested and c ertified by a nationally recognized testing and certification agency to American
National Standards Institute - ANSI Gas Appliance Safety Standards. The Mendota Gas DXV Fireplace has been tested and certified by Intertek Testing Services 8431 Murphy Drive, Middleton, WI
Fireplace Includes A Sealed Combustion System, 9-Piece Ceramic Fiber Log Set & Coals, Firebrick Lined Firebox, Neo-
Ceram Glass, Piezo Igniter, Dual Blowers, Aga Certified Safety System, and Smart Thermostatic Remote Control.
Options : Black, Brass, Classic Brass Or Classic Silver Tone Grill Sets, Black Or 24k Gold "Victoria" & “Tuscany” Filigree
Fronts, Bentley Arched Doors, Andover Arched Doors & 4 C olor Overlay Fronts, Prairie Rectangular Doors & 4 C olor
Overlay Fronts, Deerfield Front, Wellington Front, Versiheat Remote Forced Air Heat Transfer System, Versiheat II Forced
Air Heat Transfer System, Thermostats.
Building Permit and Installation Inspection Approval Requirements
All installations of Mendota Fireplaces and I nserts must comply with all the requirements stated in this Installation and Operating Instructions
Manual. The Dealer and/or installer must also obtain all required Building
Permits and Inspection Approval from the local building inspection department or the local body having jurisdiction. In order to validate warranty coverage, Mendota may require facsimile copies of the Building Permit and Inspection Approval forms. Fai lure to provide adequate proof that the installation conforms to all local requirements and t he requirements stated in the Installation and O perating Instructions Manual will void all applicable warranty.
INSTALLER: THESE INSTRUCTIONS ARE TO REMAIN WITH HOMEOWNER.
5
Specific Requirements for the Common Wealth of Massachusetts
The information in this section applies to all installations performed in the Common Wealth of Massachusetts only. a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes and where the side wall exhaust vent termination is less than seven
(7) feet above grade, the following requirements shall be satisfied:
(b)
1. If there is no carbon monoxide detector with an alarm already installed in compliance with the most current edition of NFPA 720, NFPA 70 and the Massachusetts State Building code in the residential unit served by the side wall horizontally vented gas fueled equipment, a battery operated carbon monoxide detector with an alarm shall be installed in compliance with the most current edition of NFPA 720. NFPA 70 and the
Massachusetts State Building Code.
2. In addition to the above requirements, if there is not one already present, a carbon monoxide detector with an alarm and a battery backup shall be installed and located in accordance with the installation requirements supplied with the detector on the floor level where the gas equipment is installed. The carbon monoxide detector with an alarm shall comply with 527 CMR, ANSI/UL 2034 Standards or CSA 6.19 and the most current edition of NFPA 720. In the event that the requirements of this subdivision cannot be met at the time of the completion of the installation of the equipment, the installer shall have a period of thirty (30) days to comply with this requirement; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed in compliance with the most current edition of NFPA 720, NFPA 70 and the Massachusetts State Building Code. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the carbon monoxide detector may be installed on the next adjacent habitable floor level. Such detector may be a battery operated carbon monoxide detector with an alarm and shall be installed in compliance with the most current edition of NFPA 720, NFPA 70 and the Massachusetts State Building Code.
3. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half
(1/2) inch in size, “GAS VENT DIRECTLY BELOW, KEEP CLEAR OF ALL OBSTRUCTIONS”
4. A final inspection by the state or local gas inspector of the side wall horizontally vented equipment shall not be performed until proof is provided that the state or local electrical inspector having jurisdiction has granted a permit for installation of carbon monoxide detectors and alarms as required above.
EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2) (a) 1 through 4:
1. The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and
(c)
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.
When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions for installation of the equipment and the venting system shall include:
1. A complete parts list for the venting system design or venting system; and
2. Detailed instructions for the installation of the venting system design or the venting system components.
(d) When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies “special venting systems”, the following shall be satisfied:
(e)
1. The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and
2. The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.
A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.
6
SAFETY AND WARNING INFORMATION
READ and UNDERSTAND
all instructions carefully before starting the appliance. FAILURE TO FOLLOW these instructions may result in a possible fire hazard and will void the warranty.
Any safety screen or guard removed for servicing must be replaced before operating this appliance.
DO NOT USE this appliance if any part has been under water. Immediately CALL a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control, which has been underwater.
THIS UNIT IS NOT FOR USE WITH SOLID FUEL
.
Installation and repair should be PERFORMED by a qualified service person. The appliance and venting system should be
INSPECTED
before initial use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding, material, etc. It is IMPERATIVE that the unit’s control compartment, burners, and circulating air passageways ARE KEPT CLEAN to provide for adequate combustion and ventilation air.
Always KEEP the appliance clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
NEVER OBSTRUCT
the flow of combustion and ventilation air. Keep the front of the appliance CLEAR of all obstacles and materials for servicing and proper operation.
Due to high temperature, the appliance should be LOCATED out of traffic areas and away from furniture and draperies.
Clothing or flammable material SHOULD NOT BE PLACED on or near the appliance.
Children and adults should be ALERTED to the hazards of high surface temperature and should STAY AWAY to avoid burns or clothing ignition. Young children should be CAREFULLY SUPERVISED when they are in the same room as the appliance.
These units MUST use one of the vent systems described in the Installing Your Fireplace section of the Installers Guide.
NO OTHER
vent systems or components MAY BE USED.
This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chimney serving a separate solid fuel-burning appliance. Each gas appliance MUST USE a separate vent system. Common vent systems are PROHIBITED.
If the vent-air intake system is disassembled for any reason, reinstall per the instructions provided for the initial installation.
The vent system assembly for this fireplace must be periodically examined by a qualified service agency.
INSPECT
the external vent cap on regular basis to make sure that no debris is interfering with the airflow. The flow of combustion and ventilation air not to be obstructed
DO NOT abuse the glass door by striking the glass, slamming the door shut, etc.
Use only authorized parts and materials obtained from Johnson Gas Appliance Company when replacing defective or damaged glass.
DO NOT USE
abrasive cleaners on the glass door assembly. DO NOT ATTEMPT to clean the glass door when it is hot.
Turn off the gas before servicing this appliance. It is recommended that a qual ified service technician perform an appliance check-up at the beginning of each heating season.
DO NOT
place furniture or any other combustible household objects within 36 inches of the fireplace front.
CAUTION: Do not operate the appliance with glass removed, cracked or broken. Replacement of the panel(s) should be done by a licensed or qualified service person.
7
CONGRATULATIONS
You are the owner of a world-class heat producing gas direct vent sealed combustion fireplace.
This elegant, highly efficient Fireplace will be a constant source of comfort and fascination. It will be the focal point of beauty and interest in your home.
The Mendota Gas Fireplace is a true heating appliance incorporating the traditional aesthetics of fireplace fire viewing with the controllability and fuel efficiency of a home gas furnace. Of particular interest is the low fuel consumption and brilliant fire viewing afforded by the realistic Premium Fiber wood fire-like combustion system.
Carefully read the following instructions prior to actual installation. Proper Mendota Gas Fireplace installation and operation will give you years of safe, trouble free comfort and enjoyment.
If you have any questions regarding installation or operation of your Mendota Fireplace please contact your local dealer.
CAUTION
Due to high temperatures, the Fireplace should be located out of traffic and away from furniture and draperies. Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the Mendota Gas Fireplace.
Clothing or other flammable material should not be placed on or near the Fireplace.
Any safety screen or guard removed for servicing an appliance must be replaced prior to operating this appliance.
The Mendota Gas Fireplace is a powerful and efficient heating unit. It has been designed as a major source of supplemental heat. As with any mechanical appliance there can be component shut downs. It is advisable to have an alternate heat supply.
Installation, repair and any adjustments to logs or burner must be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, carbon build-up, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean. The burner and pilot flames and logs should be visually checked periodically.
DO NOT use this appliance if any part has been under water or exposed to moisture corrosion. Immediately call a qualified service technician to inspect the Fireplace and replace any part of the control system and any gas control, which has been under water. DO NOT use this fireplace if the burner does not light immediately . Turn unit off and call Mendota approved service person if there is any delay in burner light off.
It is Johnson Gas Appliance Company's policy that no responsibility is assumed by the Company or by any of its employees or representatives for any damages caused by an inoperable, inadequate, or unsafe condition which is the result, either directly or indirectly, of any improper operation, installation or servicing procedures.
Building Permit and Installation Inspection Approval Requirements
All installations of Mendota Fireplaces and Inserts must comply with all the requirements stated in this Installation and Operating Instructions Manual. The Dealer and/or installer must also obtain all required Building Permits and Inspection Approval from the local building inspection department or the local body having jurisdiction. In order to validate warranty coverage, Mendota may require facsimile copies of the Building Permit and Inspection Approval forms. Failure to provide adequate proof that the installation conforms to all local requirements and the requirements stated in the Installation and
Operating Instructions Manual will void all applicable warranty.
INSTALLER: THESE INSTRUCTIONS ARE TO REMAIN WITH HOMEOWNER.
HIGH ALTITUDE INSTALLATION INFORMATION: Prior to installing at altitudes higher than 7500, please contact the Mendota technical service department for specific venting requirements and venting restrictions.
8
GENERAL INFORMATION
Your Mendota Gas Fireplace has a state-of-the-art co-axial direct vent, sealed combustion system. This advanced, highly efficient system brings in outside air for combustion and efficiently heats and re-circulates room air. The Mendota system maintains high air quality, maximizes efficiency and assures proper operation in today's "tight" homes.
SAFETY AND STRUCTURAL CONCERNS
This Fireplace must be installed and serviced by a Mendota approved service person. Any adjustments to burner, pilot, logs or coal bed must be made by a Mendota approved service person. If pilot goes out always wait five (5) minutes before relighting pilot. ALWAYS!
VENTING REQUIREMENTS
This Mendota Fireplace can be vented using AMERIVENT, DURAVENT, SELKIRK METALBESTOS, SECURITY
CHIMNEY and ICC brands of coaxial pipe off the top. Use only Mendota specified vents and vent caps when installing your fireplace. Closely follow venting locations, directions and requirements. Observe the restrictions relating to vent position on exterior of home. Be sure all vent pipe sections are fully twist-locked and leak-proof. Be sure Milpak Sealant is used on the inner pipe joints of all Simpson DuraVent pipe components and all adjustable pipe sections manufactured by
Simpson DuraVent and American Metals.
REMOVE THE GLASS WHEN LIGHTING THE PILOT FOR THE FIRST TIME. The burners must light immediately & the flame must travel promptly and smoothly around "curves" and light entire burner. The flame must not "lift" off burners. DO
NOT operate unit if burner does not light immediately or if flame lifts off burner.
peting, vinyl or other combustible material other than wood flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance. Combustible mantels may be installed above top of the heat outlet grills. How far out the mantel may protrude past the front face of this appliance is dependent on the distance from
with steel protector plate on underside can be installed at any desired height above upper grill.
Never block upper or lower grills. Always use Mendota grills and Mendota approved vent systems and vent caps.
A non-combustible hearth protector is required and must extend a minimum of 12" in front of the fireplace. If fireplace is raised off floor 6" or more, no hearth protector is required.
HEATING PERFORMANCE
Mendota Gas Built-in Fireplaces are true, high efficiency gas heaters. With its high heat output the Mendota Fireplace will heat a large area of your home if situated to maximize heat circulation. Air movement options for maximizing heat circulation, which can be considered, are through-the-wall grills or floor grills, the continuous operation of central heating furnace blowers, or ceiling fan. The most efficient method for overall heat distribution is a ceiling fan. The heat output of the
Fireplace can be reduced by up to 23,000 BTUH by slowly turning the Hi/Lo temperature knob on the gas valve counter clockwise from "Hi" to "Lo" and also turning OFF the rear burner using the Rear Burner ON/OFF Switch. Blower can also be turned down to reduce heat output.
AESTHETIC CONSIDERATIONS
Burning or static fireplaces are a major aesthetic focus in any room. Locate your gas fireplace as you would a television set. The Mendota Hearth Gas Fireplace will be a continuing source of comfort and fascination. Corner installations will afford you the greatest potential for viewing in many rooms.
We suggest installing the Mendota Fireplace 6 to 12 inches above the floor by utilizing an elevated hearth.
ELECTRICAL REQUIREMENTS
A 115-volt electrical service must be supplied at the fireplace location at the time of installation. It must be electrically grounded in accordance with local codes or in their absence with current edition of the National Electric Code ANSI/NFPA
70. Electrical Service must enter this appliance at the Right Side Junction Box. Power supply to blower must be continuous. DO NOT use switches or speed control devices in power supplied to fireplace.
The blower on this appliance is equipped with a three-prong plug for protection against shock hazard and should be plugged directly into the grounded three-prong receptacle provided with the fireplace. Do not cut or remove the grounding prong from the plug. NOTE: The blower output can be adjusted with the Remote Transmitter. There will be delays in blower operation during "heat-up" (approx. 10 min.) and extended blower operation during "cool-down" (approx. ½ hr.) of unit.
Wall Thermostats are NOT recommended for this appliance. A Thermostatic Remote Transmitter is supplied with this appliance. Consult your dealer or the Mendota Service Department if you wish otherwise.
9
VENT OPTIONS DISCUSSION
This Mendota Fireplace can be vented using AMERIVENT, DURAVENT, SELKIRK METALBESTOS, SECURITY
CHIMNEY and ICC brands of coaxial pipe off the top. Use only Mendota specified vents and vent caps when installing your fireplace. Closely follow venting locations, directions and requirements provided in this Manual. Observe the restrictions related to vent position on exterior of home.
Make certain that all vent pipe sections are fully twist-locked and leak-proof. Note: When using Dura-vent pipes it is recommended that you use a silicate stove masonry sealant [Milpak Sealant #65-06-00909] on all inner pipe joints. On the exterior (air intake) pipe joints, high temperature foil tape may be used instead of the masonry sealant. Contact your dealer to obtain this sealant material.
TOP VENTING
The DXV-35 Fireplace comes from the factory configured for venting off the top using 4” x 6-5/8” Coaxial Vent Pipes.
AMERIVENT, DURAVENT, SELKIRK METALBESTOS, SECURITY CHIMNEY and ICC brand pipes and venting components may be used when venting off the top.
Venting off the top on the DXV-35 Fireplace provides a large degree of flexibility for many venting configurations. However, a few critical limitations must be understood and adhered to.
Limitation 1:
A 12” minimum vertical pipe section must be connected to the top starter collar of the DXV-35. With the
12” vertical section connected, you may only install one 90-degree elbow and a run a maximum 6” horizontal pipe section before connecting the horizontal vent cap.
Limitation 2
: The maximum horizontal run allowed when venting off the top is 12 feet preceded by a minimum 4 feet vertical run. This 12 feet horizontal run can only be used if a straight vertical run of 48 inches (4 feet) is connected directly to the top of the dxv35. Do not exceed the maximum 12 feet horizontal run. Even if the vertical section you installed is greater than 4 feet, do not exceed the 12 feet maximum horizontal run throughout the entire vent system
10
GAS SUPPLY REQUIREMENTS
Correct gas pressure and proper gas supply line sizing is imperative to the successful performance of your Mendota gas fireplace. Be sure the gas supplier or plumber carefully checks for correct gas pressure and gas line sizing when installing the fireplace.
It is critical to carefully check for gas leaks when hooking up the fireplace -- check with soap & water solution.
Be sure to install "approved" flex gas line with brass-to-brass fittings to prevent gas leaks at connections.
Gas supply piping must include a drip leg to eliminate the possibility of contaminants entering the gas train.
Adhere strictly to local and national codes for entire installation.
GAS SUPPLY LINE SIZING
The Mendota Gas Fireplace comes equipped with a 12” flexible connector kit including a manual shutoff ball valve. Gas supply piping must enter the Fireplace cabinet from the right side.
The included manual shut-off valve meets Federal Codes. I required by local codes, install an additional manual shutoff valve upstream of the fireplace’s manual shutoff valve. The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ PSIG
(3.5 kPa).
The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 PSIG (3.5 kPa).
A proper gas line diameter must be selected to run from the supply regulator to the Fireplace. Refer to the following table for proper gas pipe diameters. Strictly adhere to the correct pipe sizes. If in doubt, use the next larger size.
PIPE LENGTH
(FEET)
SCHEDULE 40 PIPE
INSIDE DIA.
TUBING, TYPE L
OUTSIDE DIA.
0-10
10-40
40-100
100-150
150-200
NAT.
1/2" (1.3 cm)
1/2" (1.3 cm)
1/2" (1.3 cm)
3/4" (2.0 cm)
3/4" (2.0 cm)
L.P.
3/8" (1.0 cm)
1/2" (1.3 cm)
1/2" (1.3 cm)
1/2" (1.3 cm)
1/2" (1.3 cm)
NAT.
1/2" (1.3 cm)
5/8" (1.6 cm)
3/4" (2.0 cm)
7/8" (2.3 cm)
7/8" (2.3 cm)
L.P.
3/8" (1.0 cm)
1/2" (1.3 cm)
1/2" (1.3 cm)
5/8" (1.6 cm)
3/4" (2.0 cm)
NOTE: Some areas allow copper tubing or galvanized pipe - check with local approval agencies and codes. NEVER
use plastic pipe.
GAS PRESSURE CHECKING REQUIREMENTS
should use these fittings for setting the correct gas pressure during initial installation.
NOTE: DO NOT DAMAGE OR KINK THE FLEX CONNECTOR. CHECK FOR GAS LEAKS WITH SOAP AND WATER
SOLUTION.
NOTE: 3/8" FLEX OR RIGID PIPING MAY BE USED TO CONNECT GAS SUPPLY TO UNIT DEPENDING ON STATE
AND LOCAL CODES.
NOTE: BE SURE TO INSTALL FLEX GAS HOSE WITH BRASS-TO-BRASS FITTINGS TO PREVENT LEAKS AT
CONNECTION.
NOTE: THE HARD PLUMBING FITTING PROVIDED IS TO BE USED WITH INSTALLATIONS REQUIRING HARD
PLUMBING. IT MAY BE REMOVED IF THE FIREPLACE IS BEING INSTALLED WITH A FLEXIBLE
CONNECTOR.
11
GAS PRESSURE REQUIREMENTS
A MAJOR CAUSE OF OPERATING PROBLEMS WITH GAS APPLIANCES CAN BE IMPROPER GAS PRESSURE!
Problems such as changes in flame color or flame height, pilot or burner outages, intermittent operation, changes in heat output, excessive burner noise, etc. are nearly always the result of changes in gas pressure or improper gas pressure at the time of the installation. The most important item to check during the installation and the first thing to check when problems occur is gas pressure!
Gas supplies normally enter a residence at 1/2 PSI (13" - 15" W.C.) (3. KPA). A regulator is then placed inside the residence, which drops this pressure to 7" W.C. (1.8 KPA) (Nat. Gas). This "inches to inches" regulator is of adequate capacity to service the gas appliances (such as dryer, furnace, etc.). If this regulator's capacity is not sufficient to add the Gas Fireplace, an additional "inches to inches" regulator must be installed for the Fireplace. EXCEPTION: Some codes allow 2-PSI (1.4KPA) supplies to enter the residence, in which case "pounds to inches" regulators are used.
The following table provides information on correct gas pressure requirements. Be sure your gas supplier or plumber carefully follows this table.
GAS PRESSURE REQUIREMENTS
DESIRED
INLET
PRESSURE
MINIMUM
INLET
PRESSURE
MAXIMUM
INLET
PRESSURE
MANIFOLD
OUTLET
PRESSURE
AIR SHUTTER
POSITION*
NATURAL GAS 7.0" W.C.
(1.75 kPa)
5.0" W.C.
(1.12 kPa)
11" W.C.
(2.61 kPa)
3.5" W.C.
(0.87 kPa)
1/16 - 3/16 "
OPEN
L.P. GAS 12.0" W.C.
(3.00 kPa)
11" W.C.
(2.75 kPa)
13.0" W.C.
(3.24 kPa)
10.0" W.C.
(2.5 kPa)
1/4" OPEN-MIN.
TURN GAS VALVE KNOB TO "HIGH" POSITION. GAS PRESSURES MAY VARY PLUS OR MINUS 5%.
NOTE: For High Altitude (Above 5.000 Feet) Some Variations In Air Shutter Settings May Be Required.
Manifold pressure must be taken at the Output Pressure tap and inlet pressure at the Inlet Pressure tap with the burner
operating by a qualified installer (see Figure 1: Gas Pressure Test Port ).
Figure 1: Gas Pressure Test Ports
12
EXTERIOR VENT LOCATIONS AND RESTRICTIONS
Figure 2: Exterior Vent Locations
A =
B =
ALL MEASUREMENTS GIVEN ARE FROM THE CENTER LINE OF VENT CAP
∨ -
Vent Terminal
∧ -
Air Supply Inlet
≡ -
Area where terminal is not permitted
Clearance above grade, veranda, porch, deck, or balcony (*12 inches (30 cm) minimum). Vinyl surfaces require 24” min.
Clearance to window or door that may be opened
(*12 inches (30 cm) minimum.
H = *Not to be installed above a meter/regulator assembly within 3 feet (90 cm) horizontally from the center-line of the regulator
I =
C = Clearance to permanently closed window (minimum 12 inches (30 cm).
J =
Clearance to service regulator vent outlet (*6 feet (1.8m) minimum)
Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance.
*12 inches (30 cm) minimum.
D =
E =
Vertical clearance to ventilated soffit located above the terminal from the center-line of the terminal (12 inches (30 cm) minimum) Vinyl surfaces require 24” min.
Clearance to unventilated soffit (18 inches (46 cm) minimum) Vinyl surfaces require 24” min.
K = Clearance to a mechanical air supply inlet (*6 feet (1.8 m) minimum)
L =
†
Clearance above paved side-walk or a paved driveway located on public property (*7 feet (2.1 m) minimum)
F = Clearance to outside corner - 6 inches (15 cm).
Clearance to inside corner - 12 inches (30 cm).
Vinyl surfaces require 24” min.
M = Clearance under veranda, porch, deck, or balcony (*18 inches (30 cm) minimum ‡)
G =
N= Minimum 24” horizontal clearance to any surface, such as an exterior surface, for vertical terminations.
†
A vent shall not terminate directly above a sidewalk or paved driveway, which is located between two single-family
dwellings and serves both dwellings.
‡
Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.
* As specified in CGA B1:19 Installation Codes (1991). Note: Local codes or regulations may require different clearances.
13
GENERAL FLUE VENTING INSTRUCTIONS
The Mendota Fireplace must be vented using Amerivent, Duravent, Selkirk Metalbestos, Security Chimney or ICC Brand venting systems. All warranties will be voided and serious fire, health or other safety hazards may result from any of the following actions: Installation by unauthorized personnel; installation of any damaged component; unauthorized modification of vent system; installation of any components not approved by Mendota; failure to meet all clearance requirements; failure to properly twist-lock and positively seal all components. Consult local building codes before beginning the installation.
WARNING
Always maintain required clearances (air spaces) to combustibles to prevent a fire hazard. Do not fill air spaces with insulation. Check installation instructions for minimum clearance requirements between the outer walls of the vent pipe and nearby combustible surfaces. Be sure to check the vent termination clearance requirements from decks, windows, soffits, gas regulators, air supply inlets, and public walkways, as specified in these installation instructions and local building codes. SAFETY PRECAUTIONS FOR THE INSTALLER: 1) Wear gloves and safety glasses for protection; 2) Exercise extreme caution when using ladders or on rooftops; and 3) be aware of electrical wiring locations in walls and ceilings.
The gas appliance and vent system must be vented directly to the outside of the building, and never attached to a chimney serving another solid fuel or gas burning appliance. Each direct vent gas appliance must have its own separate vent system. Common vent systems are prohibited.
To assure proper venting performance of the high-performance Mendota Direct Vent Fireplace, it is critical that all brands of vent pipe sections are sealed tightly and leak-proof. This means that all pipe sections must be carefully rotated into the fully "twist-locked" position.
We Strongly Recommend That Fixed Length Pipe Sections Be Used In Place Of Telescoping Sections Whenever
Possible.
Note: When using vent pipe and components that do not incorporate a fiberglass or graphite gasket at the joints, it is recommended that you use Milpak 1000F silicate stove sealant (#65-06-00909). High temperature foil tape may be used on the outer (air intake) pipe joints.
DO NOT SEPARATE ADJUSTABLE TELESCOPING SECTIONS. THEY MUST BE USED AS COMPLETE
ASSEMBLIES.
VENT COMPONENTS "TWIST-LOCK" CONNECTION PROCEDURE
DuraVent and American Metals pipe and fittings are designed with special twist-lock connections. Twist-lock procedure is as follows: four (4) indentations, located on the female ends of pipes and fittings are designed to slide straight in to the male ends of the adjacent pipes and fittings, by orienting the four pipe identifications so that they match and slide into the four entry slots on the male ends (Figure 3).
Push the pipe sections completely together then twist-lock one section clockwise, approximately ¼ turn until the two sections are fully locked. The female locking lugs will not be visible from the outside on the black pipe or fittings. They may be located by examining inside of the female ends .
Figure 3: Twist-Lock Piping
14
GENERAL INSTALLATION INSTRUCTIONS
CAUTION: Each installation must conform to all local, state and national codes. Refer to the national fuel gas code and local zoning and code authorities for details on installation requirements. The Mendota Fireplace must be vented to the outside in accordance with the latest edition of the National Fuel Gas Code. In the absence of local codes, the installation must conform to the most current edition of the National Fuel Gas Code ANSI Z223.1, also known as NFPA 54. NOTE: The Mendota DXV Fireplace is approved for mobile home and bedroom installations.
CAUTION: The Mendota DXV Fireplace may be installed in a manufactured (mobile) home after the first sale of the home. Manufactured home (mobile home) installation must conform with the Manufactured Home Construction and Safety Standard, Title 24
CFR, Part 3280, or, when such a standard is not applicable, the Standard for Manufactured Home Installations, ANSI A225.1/NFPA
501A, or CSA Z240.4-Gas Equipped Mobile Housing. Consult your local building official. Note: For mobile home installations unit must be bolted to the floor and properly grounded.
This Fireplace must be installed by a qualified service person.
1.
After selection of the desired fireplace location, prepare the rough opening using framing dimensions on PAGE 164.
Be sure to also prepare opening to allow for co-axial vent (see "Flue Venting Instructions".
2. Check to make certain all venting requirements and clearances are being followed.
3. The Fireplace is designed to be installed into rough framing. The drywall will cover the adjustable nailing flanges on the Fireplace sides. Before sliding the Fireplace into the framed opening, adjust the nailing flanges to accommodate the thickness of the wall material. NOTE: FRAMING MATERIALS LOCATED ABOVE FIREPLACE BODY MUST
MAINTAIN CORRECT CLEARANCES TO VENT PIPE.
WARNING
DO NOT COVER THE 2” BLACK FRONT SURFACE OF THIS UNIT IF YOU INTEND TO USE THE ANDOVER,
BENTLEY, DEERFIELD or WELLINGTON TRIMS!!
4. Slide Fireplace into the rough framed opening. When finishing the unit, combustible materials may overlay nailing flanges and come in contact with the edges of the black front surface, but may not overlap the 2" black front surface.
Noncombustible material, such as marble, stones or brick, can be installed over the 2" black surface, only if you are certain that a Deerfield Front, Andover Front, Bentley Front, Prairie Front or a Wellington Front is NOT
going to be used as the optional trim, up to the inside edge of black frame (next to glass). ROUGH FRAMING
CAN COME NO CLOSER TO UNIT THAN THE STAND-OFFS.
5. Level the Fireplace and secure into opening by nailing through the nailing flanges on cabinet side panels. Holes are provided in fireplace floor behind grill to secure fireplace to floor using lag screws or drywall screws, if required.
NOTE: A removable panel in the enclosure for future visual inspection of flue connection is recommended.
6. Have an electrician install a 115-Volt supply to the junction box on lower left side of the fireplace cabinet. Connect wires to the duplex outlet. This duplex outlet is removable from outside of cabinet for easy wiring. Make sure the outlet is properly grounded and that the installation conforms to all local and national wiring codes.
7. Have gas supplier or qualified plumber install gas supply line to fireplace and connect to gas nipple. Be sure Gas
Supply Requirements (see PG. 9-10) and all local and national codes are carefully followed.
IMPORTANT: Any safety screen, guard, glass or grills removed for servicing a fireplace/room heater must be replaced prior to operating the fireplace/room heater.
BLOWER OPERATION
This fireplace is designed so the blower operates continually when the body is of this fireplace is hot and the main burner(s) are on. The blower output can be regulated with the included blower speed control rheostat. NOTE: There will be a delay before the blower operates during "heat-up" (approx. 10 minutes) and extended blower operation during "cooldown" of unit (approx. ½ hour).
OPERATION DURING POWER OUTAGES
The fireplace is designed to operate during power outages for 1-1/2 continuous hours, Maximum on HIGH FIRE. The blower will not operate, but natural convection can be improved by removing the upper grill and opening the screen doors (depending on the type of optional front installed). After 1-1/2 continuous hours of operation, during the power
15
outage, turn off the burners for 1 hour and allow the fireplace to cool down. Consecutive 1-1/2 hour burn and 1 hour cool down cycles are allowed. On LOW FIRE (front burner only), you may operate continuously during power outage.
MENDOTA DXV-35 GAS DIRECT VENT FIREPLACE
SPECIFICATIONS & CLEARANCES
WARNING : Do not cover the 2” faceplate border of the unit with combustible materials.
26 1/2
6"MIN.
1"MIN.
22 5/16
11 1/8
37 7/16
10 3/4
4 1/2
15 3/8
16 1/4
35 7/8 1/2 TO
2 1/2
10 "
45°
MINIMUM FRAMING DIMENSIONS
FOR THIS FIREPLACE
HEIGHT
WIDTH
31-1/2
(800 mm)
37 1/8
(943 mm)
DEPTH
Adjacent Walls:
A wall, perpendicular to and in front of the appliance front facing must be at least 10" from the firebox opening. A wall at 45° to the front and starting at the appliance's outer edge is permitted. Projections behind this wall (shaded area) are permitted.
52 1/2
1
2
COMBUSTIBLE MANTEL
TRIANGULAR AREA. FOR
MUST REMAIN IN THIS
EVERY 1" INCREASE IN
MANTEL DEPTH, INCREASE HEIGHT ABOVE GRILL
BY 2". MANTEL MAY BE LOWERED
DECREASED IN THE SAME MANNER
IF DEPTH IS
2" MIN.
8" COMBUSTIBLE MANTEL
8" MANTEL
DEPTH (WIDTH)
36 1/4 TO SCREW HEADS 14
14" MANTEL
HEIGHT FOR
8" MANTEL
1"
MIN.
16 1/4 MIN.
FROM TOP
OF UNIT
TO STACK
CENTER
41
31 7/16
27
28 3/8
32 5/8 16 1/16 31 11/16
52 1/2" MIN.
CLEARANCE TO
COMBUSTIBLE
ABOVE UNIT
& MINIMUM
CEILING HEIGHT
4 21/32
GAS INLET
2 7/16
1 15/16
IF MANTEL IS MADE OF A NON-COMBUSTIBLE MATERIAL
(BRICK, STONE, ETC..), OR HAS A STEEL PROTECTOR PLATE
ON THE UNDERSIDE IT MAY BE PLACED ANYWHERE ABOVE GRILL
NON-COMBUSTIBLE
HEARTH PROTECTOR
REQUIRED
85-03-00458
12
NOTE:
FOR EVERY 1" THE FIREPLACE IS RAISED OFF THE FLOOR,
HEARTH PROTECTOR MAY BE REDUCED BY 2".
IF FIREPLACE IS RAISED 6" OR MORE, NO HEARTH PROTECTION IS REQUIRED.
Figure 4: Specifications & Clearances
NOTE: For L.P. & High Altitude (above 4,000 ft. but below 7500 ft.), 45º elbows must be used in place of 90º elbows . For
Installation At Altitudes Above 7,500 Feet, First Call Mendota Technical Hotline For Further Information On The Strict Requirements For Installations At These Altitudes.
CAUTION: If 90ºelbows must be used with LP or at high altitudes, a 2-foot vertical starter section must be used directly off the top of the fireplace.
16
TOP FLUE VENTING COMPONENTS
ITEM
1
1
1
1
2
3
4
DESCRIPTION
12" VENT STACK
24" VENT STACK
36" VENT STACK
48" VENT STACK
90
45
º
º
GALVANIZED ELBOW
GALVANIZED ELBOW
ADJUSTABLE WALL THIMBLE
5
9
6" or 7” PIPE
ATTIC INSULATION SHIELD 12"
10 ROOF FLASHING (0/12 TO 6/12)
10 ROOF FLASHING (7/12 TO 12/12)
11 STORM COLLAR
12 VERTICAL VENT CAP
13 SUPPORT BAND
14 HORIZONTAL VENT CAP
15 FIRESTOP SPACER
Using 45 o elbows in place of a 90
Figure 5: Flue Venting Components o elbow requires 22" minimum opening to center.
NOTE: DO NOT SEPARATE TELESCOPING SECTIONS. THEY MUST BE USED AS COMPLETE ASSEMBLIES.
17
FLUE VENTING ALLOWANCE CHART
NOTE: FOR LP GAS & HIGH ALTITUDE, SEE PG. 19
NOTE: FOR LPG AND HIGH ALTITUDE
APPLICATIONS, SEE PAGE 19.
Figure 6: DXV35 Vertical & Horizontal Vent Requirements
NOTE : 12” MINIMUM VERTICAL PIPE CAN BE USED IF NO HORIZONTAL VENT SECTIONS GREATER THAN 6” (or
7”) ARE USED. ALL OTHER INSTALLATIONS MUST FALL WITHIN ABOVE SHADED AREA.
18
L.P. GAS MINIMUM HEIGHT HORIZONTAL TERMINATION
L.P.
G
AS OR
H
IGH
A
LTITUDE
(
ABOVE
4,000
FT
.
BUT BELOW 7500 FT.
)
WALL THIMBLE
6" COAX
45° COAX
(MIN.)
45° COAX VENT
12" COAX
(MIN.)
TERMINATION CAP
19-3/4"
(MIN.)
49 3/4"
(MIN.)
85-03-00531
15 1/2"
Figure 7: LP MINIMUM VENT
For L.P. gas and high altitude installations (above 4,000 ft.), 45° elbows must be used in place of 90° elbows. height to center of vent cap. height from floor level will be 55-3/4" when using this minimum configuration. Adjust ceiling height upward for other configurations.
CAUTION: If 90° elbows must be used, a 24 inch vertical starter section must be used off the top of the fireplace.
19
MINIMUM RISE THROUGH-THE-WALL VENTING
:
The minimum vertical rise for vent installation through the wall is 16 1/4" from the top of the fireplace to the centerline of the 90ºelbow in installations where only a 6” (or 7”) horizontal vent section is used (refer to chart on PG.16 when using horizontal sections). NOTE: We recommend always using the most vertical rise the installation will allow. This maximizes efficiency and flame appearance. This is especially true for LP gas installations and for installations at higher altitudes.
Use "fixed" pipe sections in place of adjustable pipe sections wherever possible. 1000º sealant use is recommended on inner pipe joints. Always maintain 1" clearances from vent pipe sides and bottom to combustibles, 3" above pipes on horizontal runs and above elbows. Do not fill air spaces with insulation or other material.
For L.P. gas and High Altitude (above 4,000 ft.), 45º elbows must be used in place of 90º elbows.
NOTE: This requires 19" minimum rough opening depth (see PG. 15). CAUTION: If 90º elbows must be used, a 2-foot vertical starter section must be used directly off the top of the fireplace.
THIS FIREPLACE MUST BE INSTALLED BY A QUALIFIED MENDOTA APPROVED SERVICEPERSON.
IMPORTANT: REFER TO DRAWINGS ON PAGES 14-17 WHILE FOLLOWING THESE INSTRUCTIONS.
1. Position fireplace in desired location. See PG. 11 for guidelines on proper vent cap placement on the exterior of home. Check to determine if wall studs are in the way when venting system is attached. If this is the case, you may want to adjust the fireplace location.
2. Measure from the top of the fireplace up minimum (see Figure 4: Specifications & Clearances, PG. 164) and mark wall directly at the center of where the vent pipe will penetrate the wall.
3. Cut and frame a 9" wide x 10" high rectangle opening in the wall. The hole must be positioned so the vent system will run level or have a ¼" rise AND be perpendicular to the wall. The height of the opening must be located to meet all local and national building codes and not allow the termination to be easily blocked or obstructed. If wall being penetrated is non-combustible material, i.e. masonry block, brick, etc., a 7-inch diameter hole is acceptable.
4. Assemble the components to the fireplace adapter with pipe seams oriented toward the wall or floor -- as much out of view as possible. Be sure all vent component connections are in their fully twist-locked position and are leak-proof.
Be sure 1000ºsealant is used on the inner pipe joints of all pipe sections manufactured by Simpson DuraVent. American Metal pipe joints do not require this sealant.
NOTE: DO NOT SEPARATE TELESCOPING SECTIONS. THEY MUST BE USED AS COMPLETE ASSEMBLIES.
5. The length of the horizontal piece that fits through the wall will be determined by the thickness of the wall. When installed, the end of the horizontal piece must be flush with the exterior wall of the home. There MUST be a minimum of
1" air space clearance to combustibles from all vent pieces (3" above horizontal runs and on top of elbows).
6. A wall thimble must always be used when penetrating combustible wall materials.
NOTE: Combustible wall thickness must be 4" to 8" maximum for the wall thimble. Wall more than 8” thick will require special protection. Contact Mendota Technical services for assistance.
7. From the exterior of the home, slide the horizontal vent cap over the end of the horizontal pipe and tightly secure the cap to the wall with screws. Seal with a high quality caulking.
WARNING : Venting terminal shall never be recessed into wall cladding or siding. Vent Cap must sit on top of siding or cladding.
20
VENTING COMPONENTS LIST
45-01-00201
45-01-00202
45-01-00203
45-01-00204
45-01-00206
45-01-00207
45-01-00208
45-01-00209
45-01-00210
45-01-00211
45-01-00212
45-01-00213
45-01-00214
45-01-00215
45-01-00216
45-01-00217
MENDOTA #
45-01-00186
45-01-00187
45-01-00188
45-01-00189
45-01-00190
45-01-00191
45-01-00192
45-01-00193
45-01-00194
45-01-00195
45-01-00196
45-01-00197
45-01-00198
45-01-00199
45-01-00200
45-01-00218
45-01-00219
45-01-00220
45-01-00224
45-01-00225
45-01-00226
DESCRIPTION
7" LENGTH
12" LENGTH
24" LENGTH
36" LENGTH
48" LENGTH
ADJUSTABLE LENGTH
45 DEG. ELBOW
90 DEG. ELBOW
WALL THIMBLE
VERTICAL CAP
HORIZONTAL CAP
14" SNORKEL CAP
36" SNORKEL CAP
WALL STRAP
FIRESTOP SUPPORT PLATE
FLASHING: 0/12-6/12 PITCH
FLASHING: 6/12 - 12/12 PITCH
STORM COLLAR
ATTIC INSULATION SHIELD
CO-LINEAR APPLIANCE ADAPTOR
CO-LINEAR TOP KIT
VERTICAL KIT
HORIZONTAL KIT
HORIZONTAL KIT #2
7" LENGTH- BLACK
12" LENGTH - BLACK
24" LENGTH - BLACK
36" LENGTH - BLACK
48" LENGTH - BLACK
ADJUSTABLE LENGTH - BLACK
45 DEG. ELBOW - BLACK
90 DEG. ELBOW - BLACK
FACEPLATE, CEILING SUPPORT/ WALL THIMBLE - BLK
ROOF SUPPORT - BLACK
36" LENGTH
48" LENGTH
ADJUSTABLE LENGTH
NOTE: ALL PART NUMBERS LISTED ABOVE APPLY TO SIMPSON DURAVENT COMPONENTS ONLY.
21
ELEVATED VERTICAL RISE THROUGH-THE-WALL VENTING
The required MINIMUM vertical rise is 48 in. when used with a maximum horizontal run of 12 ft. For other venting configurations within these maximum limits, see Figure 6, PG. 18.
NOTE: All horizontal runs of vent pipe must be level or have a ¼" rise for every 1' of run toward the termination.
Never allow the vent to run downward. This will cause high temperatures and the possibility of a fire.
USING OFFSETS AND RETURNS: A single 90º vertical-to-horizontal elbow is already calculated into the allowable maximum 12' horizontal run. Each additional 90º elbow reduces the maximum horizontal distance by 3'. Example: by using three total 90º elbows the maximum horizontal distance has been reduced to 6 ft. (3 - 1 = 2 elbows x 3' = 6'; 12’ Max. - 6' of elbows = 6' of horizontal run). Note: 45º elbows reduce the maximum horizontal distance by 1½ '.
SUPPORT: Horizontal runs of pipe will require one vent support for every 3 ft. of pipe.
CAUTION: If a vertical-to-horizontal elbow is enclosed within a wall, floor or ceiling, a top air space clearance of 3" must be maintained above the elbow. Be sure to maintain 1" air space to any combustibles on the sides and bottom, 3" above horizontal pipe sections.
THIS FIREPLACE MUST BE INSTALLED BY A QUALIFIED MENDOTA APPROVED SERVICEPERSON.
IMPORTANT: REFER TO DRAWINGS ON PAGES 14-17 WHILE FOLLOWING THESE INSTRUCTIONS.
1. Position fireplace in desired location. See PG. 13 for guidelines on proper vent cap placement on exterior of home. Check to determine if wall studs are in the way when vent system is attached. If this is the case you may want to adjust the fireplace location.
2. Locate the position where vent pipe will pass through any ceilings and will penetrate the outside wall. Since vent pipe sections "overlap" we suggest pre-assembling and measuring the total vent pipe run so you can more accurately locate the point where the vent pipe will penetrate the outside wall (See Figure 2: Exterior Vent Locations,
PG. 13). Be sure all vent components are properly twist locked and leak-proof. It is recommended that 1000º sealant be used in the inner pipe joints of all pipe sections manufactured by Simpson DuraVent.
NOTE: DO NOT SEPARATE TELESCOPING SECTIONS. THEY MUST BE USED AS COMPLETE ASSEMBLIES.
3. Cut and frame a 9-1/2” wide x 10” high openings in the outside wall openings and 9” x 9” opening in ceiling openings. The outside wall hole must be positioned so the vent system will run level or have a ¼" on rise AND be perpendicular to the wall. The height of the opening must be located to meet all building codes and not allow the termination to be easily blocked or obstructed. A ceiling fire stop spacer is required at all floor (ceiling) penetrations.
4. Connect vent pipe to the fireplace adapter on top of fireplace vent outlet.
5. The horizontal pipe must end flush with the exterior wall of the home. Horizontal pipes will require proper support every 3 ft. of vent pipe. THERE MUST BE A MINIMUM OF 1" CLEARANCE TO COMBUSTIBLES ON THE
SIDES AND BOTTOM OF ALL VENT PIECES (3" above horizontal runs and above elbows).
6. A wall thimble must always be used when penetrating combustible wall materials.
NOTE: Combustible wall thickness must be 4" to 8" maximum for the wall thimble. Wall more than 8” thick will require special protection. Contact Mendota Technical services for assistance.
7. From the exterior of the home, slide the horizontal vent cap over the end of the horizontal pipe and tightly secure the vent cap to the wall with screws. Seal with high quality caulking.
WARNING
: Venting terminal shall never be recessed into wall cladding or siding. Vent Cap must sit on top of siding or cladding.
22
VERTICAL THROUGH-THE-ROOF VENTING
The
maximum vertical run of vent pipe is 55 ft. from the top of the fireplace. The fireplace will support a run of a maximum of 55 ft. The vent system must be supported every 3 feet using Support Straps. Maintain 1" air space clearances on all sides of vent components that are positioned vertically and 3” above horizontal pipe sections and components.
THIS FIREPLACE MUST BE INSTALLED BY A QUALIFIED MENDOTA APPROVED SERVICEPERSON.
IMPORTANT: REFER TO DRAWINGS ON PAGES 14-17 WHILE FOLLOWING THESE INSTRUCTIONS.
1. Place the fireplace in its desired location. Drop a plum bob from the ceiling to the position of the fireplace flue exit.
Mark the location where the vent will penetrate the ceiling. Drill a small hole at this point. Next, drop a plum bob from the roof to the hole previously drilled in the ceiling. Mark and drill the spot where the vent will penetrate the roof. Determine if ceiling joists, roof rafters or other framing will obstruct the venting system. You may choose to relocate the fireplace or choose to offset the vent system to avoid cutting load bearing members.
2. Cut and frame a 9" x 9" opening in the ceiling centered on the hole drilled in Step 1.
3. To determine the length of the vent pipe required, measure the distance from the fireplace flue outlet to the ceiling, the ceiling thickness, and the vertical rise in the attic or second story and allow sufficient vent height above roofline. For two story installations, fire stops are required at each floor level. If an offset is needed in the attic, additional pipe and elbows will be required.
4. Assemble the desired lengths of vent pipe and elbows to reach from the fireplace flue outlet. Ensure that all vent pipe and elbow connections are in their fully twist-lock position and that inner pipe joints are sealed and are leak-proof.
Maintain 1" airspace clearances to combustibles around vertical pipe sections and 3" clearance above horizontal run sections.
5. Cut a 9" x 9" opening in the roof, centered in the small drilled hole placed in the roof in Step 1. The opening should be a sufficient size to meet all clearance requirements. Continue to assemble lengths of pipe and elbows necessary to reach up through the roofline. Galvanized pipe and elbows may be utilized in the attic, as well as above the roofline.
The galvanized finish is desirable above the roofline due to its higher corrosive resistance. a) If an offset is necessary, it is important to support the vent pipe every 3 ft. to avoid excessive stress on the elbows and possible separation. Wall straps are available for this purpose. b) Whenever possible, use 45º elbows instead of 90º elbows. The 45º elbow offers less restriction to the flow of flue gases and intake air. If a 90º elbow is necessary there must be a minimum of one pipe section rise between the 90º elbow and the vent cap. A maximum of three 90ºelbows are allowed per installation.
6. Slip the flashing over the pipe sections protruding through the roof. Secure the base of the flashing to the roof with roofing nails and seal flashing to roof. Ensure the roofing material overlaps the top edge of the flashing. Verify you have at least the minimum clearance to combustibles at the roofline.
7. Continue to add pipe sections until the pipe and the vent cap meet the minimum building code requirements, as outlined in No. 8 on the following PAGE. a) For multi-story vertical installation, a ceiling fire stop is required at the second floor and any subsequent floors.
The opening should be framed to 9" x 9" inside dimensions as described in step No. 5. b) Any occupied areas above the first floor, including closets and storage spaces, which the vertical vent passes through, must be enclosed. The enclosure may be framed and sheet rocked with standard construction materials, however, be sure to maintain minimum allowable clearances between the outside of the vent pipe and the combustible surfaces of the enclosure.
8. Height "*H" of top of vent cap can be determined as follows:
9. Complete installation with storm collar and vent cap.
ROOF PITCH
FLAT to 6/12
7/12 to 9/12
10/12 to 12/12
13/12 to 16/12
17/12 to 21/12
"H" DIMENSION
FEET
2
2
4
6
8
METERS
.6
.6
1.2
1.8
2.4
23
DOOR REMOVAL AND REPLACEMENT
CAUTION
: Do not operate the appliance with glass removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person. Glass latch tool #HA-57-00743 is supplied with the unit.:
To Unlatch Glass Frame Latches:
1.) INSERT
1. Insert Glass Latch Tool into hole in latch (two latches exist at top of glass frame).
2. Pull Glass Latch Tool outward about 3/8”.
3. Rotate Glass Latch Tool 90 degrees.
4. Slowly Release Glass Latch Tool.
5. Remove Glass Latch Tool.
2.) PULL
3.) ROTATE
To Latch Glass Frame Latches, reverse steps 5 to 1, above.
To Remove Glass Frame:
1. Rotate top edge of freed glass frame outward about 15 degrees.
2. Lift Glass Frame Up and Out.
To Install Glass Frame:
1. Align and insert tabs in side flanges of Glass Frame into Slots into the slot in the side bracket.
2. Rotate Glass Frame upward until vertical.
3. Latch Glass in place per instructions above.
4.) RELEASE
GLASS FRAME ASSY.
SPRING LATCH
DETAIL A
INSERT
TAB
IN SLOT
24
GLASS FRAME ASSEMBLY REPAIR AND REPLACEMENT
DO NOT substitute other manufacturer's materials or components.
DO NOT operate unit with cracked, broken or missing glass.
WARNING
Use only authorized parts and materials obtained from Johnson
Gas Appliance Company when replacing defective or damaged glass.
WARNING
Do not operate this appliance with the glass removed, cracked or broken. Glass should be r eplaced by a licensed or qualified person. DO NOT abuse the glass door by striking the glass, slamming the door shut, etc
TO REPLACE DAMAGED GLASS
1. Using an 1/8” drill bit, drill through 3 rivets on each side of glass frame.
2. Remove glass retainer brackets and the damaged glass and gasket material. Clean the inner surface of the glass frame.
3. Assemble new gasket on glass edge starting with the bottom left corner. The adhesive on the gasket should make contact with the glass surface. Use tracer lines in gasket to determine where the glass should sit on the gasket surface.
4. Place glass and gasket assembly in glass frame. Carefully attach glass retainer brackets to sides of glass frame using new 1/8” Aluminum rivets.
The glass frame assembly and its individual components are available through Johnson Gas Appliance Company. Contact
GASKET your dealer for more detailed ordering information.
GLASS
GLASS FRAME ASSEMBLY REPLACEMENT PARTS LIST
ITEM PART NUMBER DESCRIPTION
ROTATE GASKET UP
SO ADHESIVE MAKES
CONTACT WITH GLASS
SURFACE
TRACER LINES
IN GASKET
1
2
3
HA30-00411
65-02-00103
65-06-00463
FRAME, WELDMENT, GLASS,
DXV35 DT 3
GASKET, TADPOLE,
3/8”BULB, 3/4” TAIL
GLASS, CERAMIC, DXV35
DT3
ADHESIVE
GLASS SHALL SIT BETWEEN
TRACER LINES IN GASKET
25
DXV-35 DT3 DEEP TIMBER LOG SET INSTALLATION INSTRUCTIONS
FOLLOW EACH STEP DEPICTED IN THE DIAGRAMS, BELOW, TO INSTALL THE LOG SET.
CAUTION: LOGS ARE FRAGILE, HANDLE LOG PIECES WITH CARE.
Carefully unpack 9-piece log set, bag of coals and bag of inswool. NOTE: Logs are very fragile, handle with care. Break packaging foam if log pieces are trapped within foam. Do not pull on logs!
Coals must not block pilot or burner flames ! Placement of coals has a big effect on front burner flame appearance and "glow" of coals. More coals = less yellow flame and more glow. Fewer coals = more yellow flame and less "glow".
Heat can be reduced by lowering flame height by turning the HI-LO knob. Blowers can also be turned down to reduce heat output.
Do Not “over fire" by increasing Gas Input Rate above Rating Plate specifications.
Do Not turn down pilot flame length less than 1 inch long.
DXV35 DT3 LOG SET PARTS IDENTIFICATION
(COALS AND INSWOOL BAGS ARE NOT SHOWN HERE)
26
The following Check Off Lists must be completed prior to final operation of the Fireplace, or manufacturer's warranty and liabilities will be voided:
INSTALLATION CHECK OFF LIST
Co-axial vent rigid pipe, wall vent cap or roof vent cap must be installed by a Mendota approved person in accordance with instructions. All joints must be secured, "twistlocked" and leak-proof. 1000ºF sealant use is recommended on the inner pipe joints of
DuraVent pipe sections.
Horizontal or vertical vent cap must be installed " right-side-up" and tightly sealed to structure per instructions. Vent Caps must be Mendota approved.
Clearances to combustibles requirements must be strictly adhered to.
Proper exterior and interior clearances for vent systems and locations for wall vent cap/roof vent cap must be maintained.
Carefully check for correct gas pressure, proper size gas lines and for gas leaks.
115 V electrical service and gas supply must be installed in accordance with instructions and local and national codes.
LIGHTING CHECK OFF LIST
All items on "Installation Check Off List" (see above) must be completed.
Connect thermostat, if desired. Disconnect wires connected to Main On/Off switch and connect thermostat lead wires to these two wires and run to thermostat location.
Check air shutter opening - 1/16" to 1/8" Nat. gas or 1/4" Min. LP gas.
Carefully follow all Lighting and Log Installation Instructions.
Make certain that burner lights immediately and flame runs promptly around "curve" in burner and lights entire burner. DO NOT proceed with operation unless burner cycles
"on/off" without delays.
Make certain that the flame is "stable" and does not "lift" off burner. If flame lifts off burner, turn unit off and check that all vent pipes are "twist locked" and leak proof, the vent cap is "right side up". DO NOT proceed with operation if flame is "lifting off" burner.
Note: do not separate telescoping sections. They must be used as complete as-
semblies.
Make certain glass door is in properly closed and "centered" in firebox opening.
37
BEFORE YOU BEGIN
Read this entire manual before you use your new fireplace. Failure to follow the instructions may result in property damage, bodily injury, or even death.
Intermittent Pilot Light and Standing Pilot Light Features
This gas fireplace is equipped with an electronic ignition System that first lights a pilot light then uses the pilot light to ignite the main burners. The pilot light can be set in the “Standing Pilot” mode to allow the pilot light to remain on indefinitely by toggling the “Standing Pilot Switch” to the ON position. If the “Standing Pilot Switch” is toggled to the OFF position, the pilot light will only light and remain ON while the main fireplace burners are operating.
IPI Mode:
This mode turns the pilot light “OFF” when the fireplace is not functioning and only lights the pilot light automatically when a call for heat is made by the remote control.
Standing Pilot Mode
: If the “Standing Pilot Switch” is toggled to ON, the pilot light will ignite and remain ON as long as the “Standing Pilot Light Switch” is in the ON position.
NOTE: Mendota Fireplaces recommends that the Standing Pilot Mode be used during the winter months when external temperatures fall below 50 o F. This will keep the fireplace chimney heated for proper updraft during burner ignition and it will also eliminate excessive condensation of exhaust vapors on the door glass. Further, leaving the fireplace in the Standing Pilot Mode will keep the fireplace body warm and eliminate cold drafts and heat loss to the cold air that is trapped inside the firebox.
ATTENTION!
The transmitter and receiver are RADIO FREQUENCY DEVICES. Placing the receiver in or near metal may severely reduce the signal range.
• Turn off the main gas supply of the appliance during installation or maintenance of the receiver.
• Place the receiver’s 3-position slider switch in the “off” position during installation or maintenance.
• Turn “off” main gas supply to the appliance prior to removing or reinserting the batteries in the receiver.
• During appliance installation/maintenance or in case of remote control malfunction, turn off electrical supply to this appliance and remove the batteries from the wall receiver battery compartment. Contact technical service.
CONTROL PANEL FUNCTIONS IDENTIFICATION
PILOT LIGHT
SWITCH
38
FLAME HEIGHT KNOB
Remote Control Transmitter Functions
NOTE: The Wall Receiver will “beep” once every time a Remote Transmitter Key is pressed, signaling that the command has been received.
Identify the four function buttons on the Remote
Transmitter:
1. ON/OFF KEY: This button turns the system ON or OFF. When this button is pressed and the system is OFF, the pilot light will stay ON if the “Standing Pilot Switch” is in the ON position.
2. THERMOSTAT KEY: This button, when pressed after the ON/OFF KEY is pressed and the system is ON, will allow the selection of three modes: Manual Operation, Normal Thermostat and Smart Thermostat.
1. Manual Mode: In this mode, the room temperature is ignored and the fireplace can be turned ON indefinitely.
The room temperature rise has no effect on this mode. All other functions such as fan speed control, flame height control, secondary burner On/OFF control and Accent Light ON/OFF controls will be manually controllable.
OFF
ON
SMART
2. Normal Thermostat: In this mode, the fireplace will stay functioning until the room temperature increases 1 o F above the Set Point Temperature. To increase the Set Point Temperature, Press the UP button until the desired temperature is displayed in the SET POINT TEMPERATURE window. The fan will turn on 5 minutes after fireplace startup and will turn off 12-1/2 minutes after the flames turn off, in this mode. The flame height can be adjusted while the fireplace is functioning, fan speed can be adjusted after 5 minutes of startup. Secondary burner can be turned On or Off at any time after startup.
The Accent Light can be turned on or off any time after startup.
OFF
MAX
Hi
76° F
ON
MAX
Hi
76° F
SMART
76° F
68
3. Smart Thermostat: In this mode, all other func-
MANUAL
MODE
NORMAL
THERMOSTAT
SMART
MODE tions except the flame height adjustment are allowed. Manual flame height adjustment is not allowed in this mode. The Smart Thermostat function adjusts the flame height in accordance to the difference between the set point temperature and the actual room temperature. As the room temperature gets closer to the set point temperature, the Smart Function automatically modulates the flame down.
3. UP/DOWN KEY: This key is used to increase or decrease the Set Point Temperatures, Flame
Height and Fan Speed and to toggle between Accent Light ON/OFF and Secondary Burner
ON/OFF .
4. MODE SELECTION KEY: This key is used to toggle between the various function icons : Flame
Height, Fan Speed, Accent Light and Secondary Burner.
39
REMOTE TRANSMITTER OPERATING INSTRUCTIONS
TO TURN ON THE APPLIANCE
:
1. Press the ON/OFF button. The transmitter display will show all active icons on the screen.
2. Select the Thermostat Mode by pressing the Thermostat Key: OFF (meaning Manual
Mode), ON (meaning normal Thermostat) or Smart (meaning Smart Mode). a. In OFF (Manual Mode), the appliance will ignite and start on HI. b. In ON (Normal Thermostat Mode), the appliance will only ignite if the Set Temperature is greater than the Room Temperature. c. In SMART (Smart Mode), the appliance will only ignite if the Set Temperature is greater than the Room Temperature.
TO TURN OFF THE APPLIANCE, press the ON/OFF button.
MODE KEY
Pressing the MODE KEY toggles between the various available functions: Flame Height, Fan Speed, Aux (Accent Light)
On/Off and Secondary Burner On/Off.
Flame Height: 6 flame height Levels are available. While the Flame
Height Icon is displayed, pressing the Up or Down button once will increase or decrease the flame height by 1 of 6 increments. If the flame height is at Level 1 and the Down button is pressed, all burners will turn OFF. If in IPI mode, the pilot light will also extinguish. If in Standing Pilot Mode, the pilot light will remain ON. Note: If in SMART model, the flame height function is not available for manual adjustment.
In SMART mode, the flame height regulates automatically.
Fan Speed Control: The fan speed can be adjusted through six (6) speeds and OFF. To activate this function, press the MODE
Key to index to the fan control icon. Use the UP/Down Arrow
Key to turn ON, OFF or adjust the fan speed. A single “beep” will confirm reception of the command.
Aux (Accent-Light): This function controls the Mendota Accent Light function. Pressing the UP key in this mode will TURN ON the Accent Light and Pressing the DOWN key will TURN OFF the Accent Light. A single “beep” will confirm reception of the command. Note : The Accent Light Dimmer control is located adjacent to the Remote Receiver. Turn the Dimmer Control Knob to dim or brighten the Accent Light. Once you set your desired brightness level, you may use the AUX function to turn the Accent Light On or Off at that preset level.
Secondary Burner: This function controls the Secondary Burner’s ON/OFF feature. Pressing the UP Key in this mode will TURN ON the Secondary
Burner and Pressing the DOWN Key will TURN OFF the Secondary
Burner. The flame level will not change when you turn the Secondary Burner On or Off. The flame level can only be changed in the
Flame Level mode.
40
MANUAL BYPASS OF THE REMOTE SYSTEM
If the remote transmitter is misplaced or lost, the appliance can be turned on manually by sliding the three position slider switch on the wall receiver to the ON position. This will bypass the remote control feature of the system and the appliance’s main burner will turn on. The fan will run at its maximum speed and the Accent Light may turn on.
To turn off the appliance, if the remote control is misplaced or lost, slide the three position slider switch on the wall receiver to the OFF Position.
TEMPERATURE INDICATOR ( o F or o C)
1.
Press the ON/OFF Key and Turn Off the Fireplace.
2.
Simultaneously, Press both the MODE Key and the Thermostat
Key.
3.
Look at the LCD display to verify that your desired indicator ( o F or o C) is being displayed. If not, repeat step 2.
KEY LOCK FUNCTION
To prevent unsupervised children from operating the fireplace, a KEY LOCK function is provided with this remote control system. To activate the KEY LOCK function, simultaneously press the “MODE KEY” and the “UP KEY”. To deactivate the KEY LOCK function, simultaneously press the “MODE KEY” and the “UP KEY”.
During KEY LOCK mode, none of the Keys will function. You must DEACTIVATE the system before you can use the Remote Transmitter.
LOW BATTERY POWER DETECTION
1. Transmitter Batteries: The life span of the remote control transmitter batteries depends on various factors: quality of the batteries used, the number of ignitions of the appliance, the number of changes to the room thermostat set point, etc. When the Transmitter batteries are low, a Battery Icon will appear on the LCD display of the Transmitter before all battery power is lost. When the batteries are replaced, this icon will disappear.
2. Wall Receiver Batteries: The life span of the wall receiver batteries depend on the quality of the batteries used and how long the batteries have been installed in the wall receiver. These batteries are only utilized during power outages. Replace these batteries every heating season even if you have not experienced any power outages. Batteries drain slowly even when not in use. This is a normal characteristic of all batteries.
OPERATING DURING POWER OUTAGES
This electronic ignition system utilizes the supplied 110VAC power when it is available for all functions of this system. If the
AC power is interrupted during a power outage, this system utilizes the batteries (installed in the Wall Receiver) as backup batteries. During the power outage, the appliance’s burners will function. In addition, Flame Height adjustment and
Secondary Burner ON/OFF functions will be available. The Fan and Accent Light, which are wholly dependent on 110VAC power, will not function.
This appliance is designed and tested to be operated during power outages. The overall efficiency of this appliance will be reduced by approximately 5% when the blower function is disabled during the power outage period.
41
“FIRST TIME” PILOT LIGHTING INSTRUCTIONS
IMPORTANT: Be sure all items on "INSTALLATION CHECK OFF LIST" in the Installation Manual have been completed!
CAUTION: If the pilot goes out, be sure to wait a minimum of five minutes before attempting to relight the pilot.
1. Make certain that any manual gas supply shut-off valves located upstream of fireplace are open and the receiver and the remote control transmitter are in the "OFF" position. Make certain that the receiver harness is connected to the wall receiver properly.
2. Make certain that 110VAC power is connected to Electrical Junction Box on right side of Fireplace and that the Electrical Power is “ON”.
3. Insert Batteries in the Receiver and the Remote Transmitter. Note the polarity of batteries and insert as indicated on the battery compartment covers.
4. For the “First Time Lighting”, Remove the Glass Door. This is required to purge the gas line of air and to inspect the pilot lighting spark.
5. Slide the receiver switch to “REMOTE”. Locate the “Standing Pilot ON/OFF Switch”.
6. Toggle “Standing Pilot ON/OFF Switch” to “ON”. You will hear a series of clicks and after a few seconds, you will hear sparking at the pilot spark electrode.
7. Allow adequate time for the air in the gas-line to purge. The control system will stop sparking after 30 seconds if the pilot light does not light. After a 30 second delay the control system will start sparking again for 30 seconds more. If the pilot light does not light after the third 30 second spark event, the system will enter “Lock-out” mode. To unlock from “Lock-out” mode, slide Receiver Switch to “OFF” and toggle “Standing Pilot ON/OFF Switch” to “OFF”, wait 30 seconds and slide back to “Remote”. Repeat this sequence until the pilot flame lights and the pilot is burning steadily.
7. Once the pilot flame is lit and well-established, close glass door. WARNING: NEVER IGNITE MAIN BURNERS
WITH GLASS DOOR REMOVED OR OPEN. Doing so will lead to damage to pilot flame sensor and spark elec-
trode wire leads.
8. Slide switch on Receiver to “ON”. All burners should ignite and run at “high-fire”. Slide Receiver switch to REMOTE after 15 seconds. Burner Flames will extinguish.
9. Perform gas inlet and outlet pressure tests and leak tests on field installed gas fittings and factory installed fittings in the gas valve compartment, at this time. Note: Burners must be ON to check outlet pressures and to leak test gas train fittings upstream of main gas valve.
INITIALIZING THE REMOTE CONTROL SYSTEM
(Synchronizing Receiver and Transmitter)
1. Place 3-position slider switch in Receiver in the “Remote” position.
2. Locate “PRG” key on Receiver Face. Use the tip of a pen/pencil or a wire clip to push the PRG button. The receiver will beep 3 times indicating that it is ready to synchronize with a Remote Transmitter.
3. Push the “ON” key on the Remote Transmitter. The receiver will beep 4 times to indicate that the Transmitter’s command is accepted and sets to the particular code of that Transmitter. The system is now initialized.
NOTE: Use this Synchronizing procedure every time the batteries are replaced in the Receiver or the Transmitter.
BLUE LCD
DISPLAY
WALL RECEIVER
3-POSITION
SLIDER SWITCH
PR
G
BATTERY
COMPARTMENT
LID
PRG KEY
ON/OFF KEY
THERMOSTAT
SELECTION KEY
UP/DOWN
SELECTION KEY
MODE
SELECTION KEY
42
REMOTE TRANSMITTER
Backup Batteries
The life span of the backup batteries depends on the quality of the batteries used and how long the batteries have been installed in the wall receiver. These batteries are only utilized during power outages. Replace these batteries every heating season even if you have not experienced any power outages. Batteries drain slowly even when not in use. This is a normal characteristic of all batteries. To prevent the batteries from bleeding while not in use, you may choose to remove the backup batteries and install them only when they are needed.
OPERATING DURING POWER OUTAGES
This electronic ignition system utilizes the supplied 110VAC power when it is available for all functions of this system. If the
AC power is interrupted during a power outage, this system utilizes the batteries (installed in the Wall Receiver) as backup batteries. During the power outage, the appliance’s burners will function. In addition, Flame Height adjustment and
Secondary Burner ON/OFF functions will be available. The Fan and Accent Light, which are wholly dependent on 110VAC power, will not function.
This appliance is designed and tested to be operated during power outages. The overall efficiency of this appliance will be reduced by approximately 5% when the blower function is disabled during the power outage period.
43
BLOWER OPERATION AND WIRING
WARNING : The Electrical Junction box within this appliance must be connected to a grounded LIVE power circuit. No switches, Light Dimmers or Fan Speed Control Devices are allowed within the same electric circuit as this appliance.
Connect only to a LIVE electrical power supply that is not controlled by any other switching device.
Dual blowers are provided as standard equipment with this DXV35 DT3 Fireplace. The dual blowers have an air output rating of 210 CFM (in free air). This Fireplace is designed to operate with the blowers turned ON when the appliance is running and hot. The blowers increase the overall efficiency of this fireplace and aid in distributing and circulating heat to the room this Insert is installed in.
BLOWER BREAK-IN PERIOD: The integrated blowers in this Insert may exhibit some bearing noise and electrical static noise during the first few hours of operation. This is normal during the break-in period. It is recommended that following the Paint Curing Cycle, the blowers be run at their maximum speed for two 3-hour periods. The blowers in a few units may take longer to break-in and may require additional operation time before all extraneous noise is eliminated.
Please allow adequate operational time (a minimum of 2 weeks) for the blowers to break-in before you contact your dealer for service.
WARNING: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
BLOWER OPERATION
This Fireplace is designed so the blower operates at all times the fireplace is operating. The blower output can be regulated with the rheostat. NOTE: There will be a time delay in blower operation during "heat-up" (approx. 10 minutes) and extended blower operation during "cool-down" of unit. (Approx. ½ hour). NOTE: Power supply to blower must be continuous. DO NOT use a switch or variable speed control in power supplied to fireplace.
OPERATION DURING POWER OUTAGES
The fireplace is designed to operate during power outages for 1-1/2 continuous hours, Maximum. The blower will not operate, but natural convection can be improved by removing the upper grill and opening the screen doors (depending on the type of optional front installed). After 1-1/2 continuous hours of operation, during the power outage, turn off the burners for 1 hour and allow the fireplace to cool down. Consecutive 1-1/2 hour burn and 1 hour cool down cycles are allowed on if fired on the maximum HIGH FIRE setting. If only the FRONT BURNER is fired, you may run this fireplace indefinitely during a power outage at this LOW FIRE setting.
44
TROUBLE SHOOTING MENDOTA GAS DXV FIREPLACE
SYMPTOM
1. Thin black coating
(soot) forms on viewing glass.
2. Humming or whistling coming from Fireplace.
3. A change in flame appearance or burner operation.
PROBABLE CAUSES
A. Incorrect gas pressure
B. Not enough combustion air
A. Normal operating noise.
A. A change in gas pressure.
B. Carbon, dirt or lint
CORRECTIVE ACTION
Have gas supplier check for correct gas pressure (7" W.C. Nat. Gas; 12"
W.C. LP Gas).
If sooting continues open air shutter on burner (see "Gas Flame Adjustment" below).
If sooting still continues, shut off unit and call Mendota service person.
NOTE: To clean glass - remove glass and wipe glass with cloth or paper towel.
Some noise is normal. It is caused by the gas supply flowing through the gas orifice. It is expected from any gas fireplace. Turning the Hi/Lo Knob on the control can reduce the noise. Turning down the flame will reduce the heat output of the unit.
Have your gas supplier check for correct gas 7" W.C. Nat. Gas; 12" W.C.
LP Gas). If flame still needs adjustment see "Flame Adjustment" below.
Clean out carbon, spider webs, lint, etc. from shutter area.
Logs and burner.
NEVER BLOCK AIR INTAKE OR OUTLET VENTS.
FLAME ADJUSTMENT
Be sure burner and logs are properly installed .
After logs have been properly installed and operated for one to one and a half hours, small additional adjustments to the air shutter may be necessary for final flame appearance. These small shutter adjustments can be made by the following procedure:
NOTE: Very small changes in shutter settings make major changes in flame appearance.
1. One Air Shutter Control is located behind lower hinged grill on the right side. This controls the rear burner shutter. This shutter control controls the rear burner flames. The front burner shutter is of the rotary-type. The front burner shutter is factory adjusted for Natural Gas at 1/8” open. For LPG, open to a minimum ¼”.
2. Light pilot; install logs and glass, and burn unit for 30 minutes.
3. If flame is too "blue" push Air Shutter Control Knob inward until flame turns yellow.
4. If flame is too "orange" or is causing sooting open shutter until flame begins to turn blue. NOTE: If sooting does not stop, turn off fireplace & call Mendota Service Person .
5.
IMPORTANT: Try each new shutter setting approx. 1/2 hour before making additional changes.
NOTE: Changes in front burner flame can be made by re-arranging the coals and rock wool. Densely packed coals will yield more glow and blue flames. Loosely packed coals will yield less glow and yellow flames.
CAUTION: Any changes in pilot flame length must be made by qualified person only.
45
CUSTOMER INFORMATION AND TROUBLE-SHOOTING
MAXIMUM ALLOWABLE SURFACE TEMPERATURE
Mendota Fireplaces comply with UL Standards for maximum surface temperatures on exposed combustible surfaces adjacent to the unit. The Maximum allowable surface temperature is 117° F. over ambient (room) temperature. Thus, if a room is 70° – 80° the exposed combustible surfaces immediately surrounding the Fireplace can have a surface temperature as high as 187° F. – 197° F. (Too hot to touch). The continuous blower operation automatically keeps temperatures within these safety limits. During power outages you may turn on the burners for maximum 1-1/2 hours at a time with a 1 hour cooling period in between the burn cycles. Do not exceed the 1-1/2 hour burn time during power outages.
OVER FIRING OF BURNER
NEVER "over fire" units by adjusting gas pressure or drilling out the orifice to increase BTUH above nameplate specifications. Over firing can cause permanent damage to firebox and deterioration of parts and void warranty.
MAINTAINING CORRECT PILOT-FLAME -- PILOT OUTAGE & RELIGHTING
If pilot flame goes out, always wait 5 minutes before relighting.
CLEANING VIEWING GLASS
The viewing glass should be cleaned periodically. Exterior glass surface may be cleaned with cleaner as desired. The
Interior glass surface should be cleaned using only soap and water or KEL KEM “Polish Plus” or comparable product.
CAUTION
: Do not use oven cleaner to clean glass. Never touch glass or attempt to clean when glass is hot.
NOTE: Additives that are put in gas (both natural and propane) to make it smell can be harmful to glass and can leave a white film deposit on the glass. This deposit can be removed with cleaners such as KEL KEM “Polish Plus” (part # 65-06-
00455) or comparable product (contact your dealer).
In some cases (especially when burning propane) additives can cause “crazing” or etching on the glass. This is not an uncommon occurrence and it is not covered under the warranty. The solution may be to change propane suppliers.
SOOTING
Sooting is caused by improper installation or operation. However, some small areas of soot deposits on log surfaces are deemed acceptable. Open the burner air shutters if you observe sooting. If you observe large soot areas (larger than
1”x2”) on log surfaces or signs of sooting on the door glass (usually a thin black film on the Fireplace viewing glass or on the outside of the home around the vent cap), open both burner air shutters. If sooting continues, the unit must be immediately turned off and the local Mendota dealer promptly informed. Mendota dealers will correct "sooting" problems, but
Mendota and their dealers are not responsible for damage caused by excessive sooting that has not been immediately brought to their attention.
46
MAINTENANCE
1. ANNUAL MAINTENANCE OF MENDOTA UNITS IS REQUIRED.
The following procedures must be performed each year by a Mendota approved service person. NOTE: Any adjustments to burner, pilot or logs must be done by a qualified Mendota service person.
A. Replace backup batteries at least 2 times annually. Replace them when the Day Light Savings Time changes.
B. Clean all lint and dust build-up around the control. Inspect the condition of any wiring under the burner for melting or damage.
C. Remove logs & coals and clean away any foreign matter (lint, Carbon, etc.) on the burner and logs. Be sure the burner ports are "open". Clean the pilot and under side of the logs for any Carbon deposits. NOTE: Logs should be visually checked for Carbon "build-up". If carbon deposits are visible on logs, unit should be turned off and Mendota service person contacted. Be sure logs are re-installed per instructions.
D. Check condition of glass door gasket, gasket must seal tightly over firebox, replace if necessary.
E. Periodically check to verify that the vent system and vent cap are open and free of blockage.
F. Before re-installing glass, have qualified service person check the operation of the pilot
G. The viewing glass should be cleaned periodically. Exterior glass surface may be cleaned with cleaner as desired.
To clean Interior glass surface, use Kel Kem “polish plus" (part # 65-06-00455) or comparable product. Do not use oven cleaner or abrasive cleaners to clean glass. Do not clean when glass is hot .
H. Periodic visual check of pilot flames is required. Pilot Flame must overlap Flame Sensor and burner ignition ports at all times.
I. Periodic visual check of main burner’s rear and front flames is required.
BURNER FLAMES GENERAL HEIGHTS REFERENCE DIAGRAM
HOOD
SPARK
ROD
FLAME
SENSOR
REAR
BURNER PILOT LIGHT FLAMES
MUST OVERLAP
BURNER PORTS.
FRONT
BURNER
47
WIRING SCHEMATICS
Note: The DXV35-DT3-LX ignition system utilizes Transformed DC power for normal ignition functions. In the event of a power outage, the Battery Pack power is utilized.
IGNITION SYSTEM WIRING SCHEMATIC
48
NATURAL TO LP GAS CONVERSION INSTRUCTIONS
Kit # HA-30-00507 Mendota Model DXV35 DT3
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the owner instructions supplied with the kit.
Motorized
LP Pressure
Regulator
[10.0-5.5"WC]
# 907.012
364
Caution: The electrical supply to the fireplace must be turned off prior to performing the conversion. The gas supply must be shut off prior to disconnecting the electrical power. Burner Orifices
#65-14-00364[3/64" DRILL]
364
ORIFICE SIZES REQUIREMENT:
A Natural Gas to LPG conversion kit #HA-30-00507 is Optional and must be purchased separately.
LP Pilot Orifice
[#977.168]
LP Conversion Kit # HA-30-00507 contains the following parts: One Motorized LP Pressure Regulator #907.012, One LP Pilot Orifice Thimble #977.168, and two Cap Orifices #65-14-00364( drill #3/64”) and an L-shaped Torx wrench.
RECOMMENDED PROCEDURE TO CONVERT THIS FIREPLACE TO BURN LPG
This Fireplace Insert arrives from the factory ready to burn Natural Gas. If you intend to burn LPG, it is highly recommended that you convert this fireplace and its Pressure Regulator, Pilot Orifice Thimble and Burner Orifices prior to placing this fireplace in its fireplace cavity.
See diagrams, on this page, and follow these instructions to prepare this fireplace for conversion to LPG.
1. Using a ¼” Hex Driver, remove 2 screws that secure the Rear and Front burners to the Burner Airbox.
2. Lift Up and remove Front Burner.
3. Loosen Front Burner Air Shutter Screw and rotate air shutter open ¼” minimum. Set burner aside.
4. Slide Rear Burner to the right about 2” and lift up and remove from Firebox.
REAR BURNER BURNERS MOUNTING
SCREWS
49
FRONT BURNER
5. Using a ½” deep well socket wrench, remove Front and Rear Orifices.
6. Thread a new 3/64” drilled orifice to both Front and Rear Orifice mounting brass fittings. Tighten down orifices.
7. Install pilot orifice thimble ##977.168 see Figure below for location. To remove Pilot Hood, use a screw driver to pry open the Wire Clip that is located at the base of the Pilot Hood. Pull Upward and remove pilot hood. Use an Alan wrench to remove NG Pilot Orifice. (Pilot orifice thimble is located inside pilot hood base).
8. Install LP Pilot Orifice. Tighten down using an Alan wrench. Replace Wire Clip in its original position.
9.
Push Pilot Hood down into base until it snaps in place.
DETAIL C
Pull Pilot Hood UP and lift UP off the base.
REAR
ORIFICE
Use an Alan Wrench
To loosen and remove
NG Pilot Orifice. Install
LP Pilot Orifice, Tighten
Down.
WIRE
CLIP.
FRONT
ORIFICE
DETAIL D
REAR
BURNER
PILOT LIGHT
HOOD
FRONT
BURNER
50
10. Before reinstalling burners, loosen the screw that secures the rotary air shutter on the Front Burner. Rotate the air shutter open to ¼” minimum.
11. Install both rear and front burners in their original locations and positions and secure down using screws you removed earlier.
12. Make certain front burner is running parallel to front face of unit positioned properly so that the pilot light hood pointing to the left is pointed properly towards the burner’s flame propagation ports.
13. Make certain Rear Burner is positioned properly so that the pilot light hood pointing to the left is pointed properly towards the burner’s flame propagation holes.
REAR
BURNER
LOOSEN SCREW
ROTATE SHUTTER OPEN
-1/4" MINIMUM-
FRONT BURNER SHUTTER ADJUSTMENT
PILOT LIGHT FLAMES
MUST OVERLAP
BURNER PORTS.
FRONT
BURNER
51
INSTALLING THE LP PRESSURE REGULATOR
WARNING:
READ AND UNDERSTAND ALL INSTRUCTIONS PACKAGED WITH LP PRESSURE REGULATOR BODY
BEFORE YOU ATTEMPT THE CONVERSION. FAILURE TO FOLLOW ALL INSTRUCTIONS WILL RESULT IN A LEAK
OR OVERFIRING OF THE APPLIANCE AND CAN LEAD TO AN EXPLOSION OR A FIRE HAZARD.
1. Remove the Courtesy Access Panel mounted behind the lower grill and lay down gently without disconnecting any wires of internal components. WARNING: DO NOT FORCE. EXCESSIVE FORCE MAY DAMAGE INTERNAL
WIRING COMPONENTS!
2. Follow Instructions given below directly from SIT Controls.
52
LP GAS PRESSURE REQUIREMENTS
Inlet and manifold gas pressure checking taps are located on gas valve. These ports are only accessible from the outer left side of the fireplace. A qualified installer shall take pressure measurements at these ports to verify and set the correct gas pressures during the LP Kit installation and before fascia materials are installed over the front of this fireplace. Manifold pressure must be taken at the “MANIFOLD PRESSURE" tap and inlet pressure at the "INLET PRESSURE" tap
burner operating by a qualified installer. with the
DESIRED
INLET
PRESSURE
MINIMUM
INLET
PRESSURE
MAXIMUM
INLET
PRESSURE
MANIFOLD
OUTLET
PRESSURE
AIR SHUTTER
POSITION
L.P. GAS 11.0" W.C.
(2.75 kPa)
11" W.C.
(2.75 kPa)
13.0" W.C.
(3.24 kPa)
10.0" W.C.
(2.5 kPa)
1/4" OPEN MIN.
(5 mm)
REGULATE THE FLAME HEIGHT TO "HIGH" POSITION. OUTLET GAS PRESSURES MAY VARY PLUS OR MINUS 5%.
LPG PROPER INPUT RATES
With the proper orifices installed, as specified above, this fireplace utilizing LP Gas will have a maximum input rate of 33,000 Btu/Hr.
LEAK TESTING REQUIREMENTS
Prior to completing the conversion process, check for gas leaks with soap and water solution at all plumbing joints prior to placing this appliance into operation. It is recommended that all gas-plumbing joints, factory installed and field installed are checked for leaks.
OUTLET TAP
PILOT FLAME AND MAIN BURNER RELATIONSHIP VERIFICATION
Prior to completing the conversion process, the qualified service technician must, light the pilot light and verify the relationship between the pilot light flames and the main burners. The pilot light flames directed towards the propagation ports on the rear and front burner must overlap the propagation ports on the burners. The pilot light flames must be a minimum of ¾” long and must overlap the propagation ports on both the rear and front burners as shown in the diagram, below. Verify that the burner tubes ignite quickly and the burner flames propagate smoothly along the entire length of the burners.
PILOT FLAME LENGTH ADJUSTMENT
If the pilot light flame length is too short and the system does not maintain a standing pilot, a qualified installer may increase the length of the pilot light flames to meet the two requirements: Minimum pilot light length to maintain a standing pilot light and the pilot light flames must be long enough to overlap the front and rear burner ports, 1 inch long minimum.
REAR
BURNER
1" MIN.
PILOT LIGHT FLAMES
MUST OVERLAP
BURNER PORTS.
FRONT
BURNER
53
CHECKING FOR NORMAL BURNER (S) IGNITION CHARACTERISTICS
Once the conversion to LPG and all the above steps have been completed, light the main burners.
Turn Gas Dial counterclockwise to "ON" then set Thermostat or push Main Burner ON/OFF switch to turn on burners.
Main burner should now light IMMEDIATELY and flame should not "lift" off burner. If there is any delay in ignition or if flame is "lifting off" burner, turn off burner and carefully check for proper installation of logs/coals, vent system and proper pilot flame impingement on burner and thermopile. Logs or coals must not block pilot flame or main burner flame. Vent system must be leak
WARNING
DO NOT PROCEED WITH OPERATION OF THIS FIREPLACE
UNLESS BURNER "CYCLES" ON/OFF WITHOUT DELAYS! proof.
ATTACHING LPG CONVERSION LABELS AND HIGH ALTITUDE DERATION LABEL
Two printed informational labels are included with the LPG Conversion Kit. Attach these two labels to the rear surface of this insert adjacent to the Serial Number Plate. If you are derating this appliance at a high altitude, also attach the High
Altitude Deration Label, supplied in the Owner’s Manual Packet, to this same surface adjacent to other labels.
Prior to attaching the labels, fill in all the information that is requested in these labels.
For installations from 610-1370 meters (2000-4500 ft.) the orifice sizes (DMS) for natural and propane gas are
_#45R/#49F_ and _#55”R/#3/64”F_, respectively. See data plate for additional information. For high altitude installations consult the local gas distributor or the authority having jurisdiction for proper rating methods. If the installer must convert the unit to adjust for varying altitudes, the information sticker must be filled out by the installer and adhered to the appliance at the time of conversion."
«Cet appareil est equipé pour des altitudes compries entre 0 et 2000 pieds (0-610 m) seulement»
This appliance has been converted for use at an altitude of ______________
Orifice size _______________
Input (Btu/h) _______________
Date of conversion _________
«Cet appreeil a été converti au ____
Manifold Pressure ________________
Fuel Type _______________________
Converted by _____________________
Injecteur ________
Pression à la tubulure d'alimentation _____________
Déoit calorifique ______________
GAS LEAK TEST REQUIREMENT: It is the responsibility of the installer/service person to assure
that each and every gas connection and supply tubing that are a part of this fireplace are leak proof.
The qualified/ certified individual connecting the gas supply line, performing pressure tests or performing any service to this fireplace is required to perform a THOROUGH LEAK TEST on ALL gas fittings that are a part of this appliance or the gas supply line connection using soap-water solution or a calibrated combustible gas detector. F ailure to perform this leak test may lead to a hous e fire and/or an explosion. Mendota is not responsible for any damages due to an Installer’s failure to conduct a leak test and verify that all connections and supply lines are leak proof.
WARNING: Do not operate appliances with glass front removed, cracked, or broken. Replacement of glass should be done a licensed or qualified service person.
Note: Consult the local or national installation code(s) to assure that adequate combustion and ventilation air is available.
WARNING: It is of the utmost importance that the correct burner orifices be installed for both the rear and front burners.
54
REPLACEMENT PARTS
PART NO
65-02-00103
MENDOTA GAS DXV-35 DT3 FIREPLACE
DESCRIPTION PART NO
TADPOLE GLASS GASKET (106”) 05-04-00050
65-06-00463 GLASS – FLAT 05-04-00052
HA-30-00415
35-01-00600
35-01-00240
35-01-00239
35-01-00601
70-01-00130
HA-82-00408
HA-30-00510
10-03-00068
05-02-00351
05-02-00364
05-02-00284
DOOR FRAME ASSEMBLY – FLAT
DEEP TIMBER III LOG SET
COALS 12 OZ BAG
GLOWING INSWOOL
HA-30-00507
65-14-00044
65-14-00049
FIREBRICK KIT
REAR BURNER TUBE WELDMENT
65-14-00364
15-02-00064
FRONT BURNER TUBE WELDMENT 15-02-00065
VALVE ASEMBLY, DXV35 DT3 05-01-00157
REAR FLAME WIRING W/ SWITCH
REAR FLAME ON/OFF VALVE
SIT VALVE NAT. GAS
HI-LO EXTENSION KNOB
10-01-00003
65-06-00125
65-06-00455
DESCRIPTION
PILOT ASS'Y. NAT.
LP PILOT ORIFICE
LP KIT
REAR ORIFICE (NAT. GAS) # 44
FRONT ORIFICE (NAT. GAS) # 49
REAR & FRONT ORIFICE (LP GAS) 3/64”
R H BLOWER WITH MOTOR
L H BLOWER WITH MOTOR
SNAP-DISC (FAN TEMP SENSOR)
RHEOSTAT/BLOWER SPEED CONTROL
BLACK PAINT - 12 OZ. SPRAY CAN
KEL-KEM GLASS CLEANER/POLISH
WARNING: Use only authorized parts and materials obtained from Johnson Gas Appliance when replacing defective or damaged glass.
DO NOT substitute other manufacturer's materials or components.
DO NOT operate unit with cracked, broken or missing glass.
WARNING: DO NOT OPERATE THIS APPLIANCE WITH THE GLASS REMOVED, CRACKED OR BROKEN.
REPLACEMNET OF GLASS SHOULD BE DONE BY A LICENSED OR QUALIFIED PERSON.
55
MENDOTA DESIGNER FRONTS INSTALLATION INFORMATION
The following Designer Fronts are available for the DXV-35 Fireplace:
1. Andover, Bentley Arched Door Kit or Prairie Rectangular Door kit with Fire screen with optional Overlays as listed below: a. Black Overlay b. Pewter Overlay c. Antique Copper Overlay d. 24K Gold
2. Wellington Fire screen Front
3. Black or 24K Gold Victoria Filigree
4. Black or 24K Gold Tuscany Filigree
5. Millennia Flat Grills in four optional color schemes as listed below: a. Black Millennia Flat Grills b. Full Brass Millennia Flat Grills c. Classic Black and Brass Millennia Flat Grills d. Classic Black and Bright Silver Millennia Flat Grills
Information specific to the installation of the Andover, Bentley and Prairie Fronts
The Andover Door and Prairie Door Fronts are designed to be “Full-Face” trim kits. These two Fronts cover an area equivalent to that shown in the diagram below. Any material that protrudes into this area on the sides, top or bottom edges can only be flush with the front surface of the fireplace faceplate.
If planning to install either the Andover Door or the Prairie Door Front, DO NOT COVER THE FACEPLATE OF THE
FIREPLACE WITH ANY MATERIALS. Furthermore, any drywall or wall covering material that is adjacent to the sides, top or bottom of the Fireplace’s faceplate may not protrude out past the front surface of the Fireplace Faceplate’s front surface.
The Andover, Bentley and Prairie Doors Mounting Faceplate (required for installation of the Andover,
Bentley and prairie Doors) may be covered over with noncombustible facing materials. See Figure 11, below.
To install Tile, Marble, Slate, Stone, Rocks or other noncombustible facings to enhance the arch shape of the Andover Doors or the Rectangular shape of the Prairie Doors, do so only after the Andover or Prairie Door Kits have been installed on the DXV-35 Fireplace.
WARNING: COMBUSTIBLE
MATERIALS MUST NOT COVER
THE FRONT SURFACE OF THE
FIREPLACE’S FACEPLATE.
Figure 9
56
Information specific to the installation of Millennia Flat Grills, Victoria Filigrees and Tuscany Filigrees
The Millennia Flat Grills, Victoria Filigree and T uscany
Filigree are designed to be “ inside-fit” trim kits. A ll of these trim kits fit within the inner perimeter of the Fireplace’s Faceplate and remain flush within the Faceplate’s front surface, see Figure below. T his fitting method allows flexibility in covering the black visible surface of the
Faceplate with non-combustible materials such as Tile,
Marble, Slate, Stone and Brick; as long as enough room is allowed for the removal of these Mendota Designer
Fronts and the glass door for servicing,
WARNING: COMBUSTIBLE MATERIALS
MUST NOT COVER THE FRONT SURFACE
OF THE FIREPLACE’S FACEPLATE.
Figure 10
Information specific to the installation of the WELLINGTON FIRESCREEN FRONT:
The Wellington Fire screen Front is designed to be
“inside-fit” trim. The top and sides of these trim kits fit within the inner perimeter of the Fireplace’s Faceplate. The bottom member of this trim, however, overlaps the bottom 2” black boarder of the fireplace front faceplate. T herefore, DO NOT COVER THE
BOTTOM 2” BOARDER OF THE FIREPLACE
FACEPLATE WHEN INSTALLING THE
WELLINGTON FIRESCREEN TRIM. The sides and top edges of the black visible surface of the Faceplate may be c overed with non-combustible materials such as Tile, Marble, Slate, Stone and Brick; as long as enough r oom is allowed for the removal of this Mendota Designer Fronts and the glass door for servicing,
Figure 11
Hearth Protection Pad Installation Information when planning to install the Wellington
DO NOT COVER THIS AREA OF THE FACEPLATE WHEN
INSTALLING THE WELLINGTON FIRESCREEN FRONT
Front
If planning to install the Wellington Front, the hearth protection pad i nstalled in front of the DXV-35 Fireplace must be des igned, built and i nstalled so that the hearth protection pad’s top surface is flush with the bottom-most surface of the DXV35 Fireplace. See FIGURE 21.
Figure 12
HEARTH PAD
SURFACE
HEARTH PAD SURFACE MUST BE
FLUSH WITH FIREPLACE BOTTOM
IF INSTALLING THE
WELLINGTON!!
57
RATING LABEL REPRESENTATION
DXV35 DT3
58
THIS PAGE LEFT BLANK INTENTIONALLY
59
MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM
As a part of Mendota's on-going program of customer satisfaction, this Form verifies proper installation and operation. It is important as a reference for future service. It insures long life and trouble-free operation of Mendota fireplaces & stoves and qualifies the owner for Mendota's lifetime limited warranty. Owner should sign Form when completed and mail a copy along with
Warranty Registration to Mendota. OPTIONALLY, PLEASE REGISTER AT OUR WEBSITE AT:
WWW.JOHNSONGAS.COM/MENDOTA-REGISTRATION.ASP
HOME OWNER: ____________________________ DEALER: _____________________________
ADDRESS: ________________________________ ADDRESS: ____________________________
CITY/STATE/ZIP: ___________________________ CITY/STATE/ZIP: _______________________
SIGNATURE: ______________________________ PHONE: ______________________________
MODEL #: DXV-35-DT3-LX __________________ SERIAL #: _____________________________
DATE INSTALLED: _______________
Mendota direct vent fireplaces are sophisticated, hi-tech gas appliances. All installation and operating instructions must be carefully followed. The DXV fireplace must be installed and serviced by a qualified Mendota approved service person.
REF: MENDOTA DXV35-DT3-LX INSTALLATION MANUAL
APPROVED VENT PIPES AND VENT CAP INSTALLED - Per Manual.
Vent pipes must be fully twist-locked and leak proof.
Check minimum and maximum vertical / horizontal and vent runs.
CHECK FOR PROPER CLEARANCES TO COMBUSTIBLES & VENT LOCATIONS - Per Manual
INSTALL PROPER SIZE GAS LINES - CHECK FOR GAS LEAKS - Per Manual
CHECK FOR CORRECT GAS PRESSURE AT MANIFOLD - Per Manual a. 3.5 Inches Water Column Maximum - Nat. Gas (1/8” WC variation is allowed) b. 10.0 Inches Water Column Maximum - L.P. Gas (1/8” WC variation is allowed)
CYCLE BURNERS ON/OFF FOR PROMPT IGNITION - Per "LIGHTING INSTRUCTIONS"
Burner must light IMMEDIATELY - Flame must travel promptly around "curve" & light burner .
INSTALL LOGS AND ADJUST FLAME - Per Manual
Proper pilot flame impingement on flame sensor & burner - Air shutter opening: 1/16" - 1/8" Nat. Gas - 1/4" LP
Check that flame is "stable" and is not "lifting" off burner
BRIEF OWNER ON OPERATION AND MAINTENANCE OF UNIT
Light Pilot Operate Burner Explain blower "delay" operation
WARRANTY REGISTRATION
Your Name ________________________________________________________________
Address ___________________________________________________________________
City _____________________________________ State ____ Zip ____________________
Dealer (Place of Purchase) ___________________________________________________
City _____________________________________ State ____ Zip ____________________
Date of Purchase ___________________ Serial Number ___________________________
Purchaser's Signature _______________________________________________________
MENDOTA DXV-35DT3 DIRECT VENT FIREPLACE
CUT OUT PAGE AND MAIL TO: JOHNSON GAS APPLIANCE CO., 520 E AVE. N.W., CEDAR RAPIDS, IOWA 52405
PLEASE REGISTER AT OUR WEBSITE AT: WWW.JOHNSONGAS.COM/MENDOTA-REGISTRATION.ASP
60
TAPE SHUT
--------------------------------------------------------------------------------------------------------------------------------------------------------
POSTAGE
NEEDED
JOHNSON GAS APPLIANCE COMPANY
520 E AVENUE N.W.
CEDAR RAPIDS, IA 52405
61
MENDOTA EXTENDED LIFETIME PROTECTION AND LIMITED WARRANTY
MENDOTA DXV-35-DT3-LX DIRECT VENT FIREPLACE
Mendota Division of Johnson Gas Appliance Company, 520 E Avenue N.W. Cedar Rapids, Iowa 52405, extends this Extended Lifetime Protection and Limited Warranty to the original purchaser of a Mendota DXV Fireplace, Serial Number, which is limited and used under normal home conditions.
STANDARD WARRANTY:
JOHNSON GAS APPLIANCE CO., MENDOTA DIVISION, WARRANTS THAT YOUR NEW MENDOTA FIREPLACE IS FREE FROM
MANUFACTURING AND MATERIAL DEFECTS FOR A PERIOD OF ONE YEAR FROM THE DATE OF INSTALLATION, SUBJECT TO
THE FOLLOWING CONDITIONS AND LIMITATIONS:
EXTENDED LIFETIME WARRANTY:
THE HEAT EXCHANGER, BURNER TUBE COMBUSTION CHAMBER AND OUTER SHELL OF THIS MENDOTA FIREPLACE ARE
WARRANTED FOR THE LIFETIME OF THE ORIGINAL OWNER, SUBJECT TO PROOF OF PURCHASE AND THE FOLLOWING
CONDITIONS AND LIMITATIONS:
4.
This new Mendota Fireplace must be installed & serviced by a competent, authorized service contractor. It must be installed and operated at all times in accordance with the installation and operating instructions furnished with the Fireplace. All adjustments to logs.
Coals or burner must be made by an authorized Mendota person. Any alteration, willful abuse, accident or misuse of the product shall nullify this warranty. This warranty does not cover glass or log breakage.
5.
This limited warranty does not cover the cost of service calls, the cost of labor to remove or install parts covered by this limited warranty, freight or other transportation expenses, which may be incurred in connection with obtaining performances under this limited warranty. The remedy for damages as the result of any defects in this product which have been warranted herein is limited to replacement parts and does not include any incidental, indirect or consequential damages or expenses sustained in connection with the product, including damages to property, except as provided by law.
6.
This warranty is non-transferable and is made to the original retail purchaser, provided the purchase was made through an Authorized
Mendota Dealer.
7.
Mendota is not responsible for any damage to or malfunction of the Fireplace unless caused by a defect in material or workmanship from normal home use. Damage caused by abuse, improper installation, improper servicing, and installation by unqualified personnel or breech of conditions of this limited warranty will excuse Mendota from performance of any part of this limited warranty. Mendota has the right to investigate and inspect the exact, original Fireplace and entire installation (without any alterations or tampering) in the event a claim is made to determine whether the claimed damage or malfunction was caused by abuse, improper installation or other cause outside this warranty. Mendota is not responsible for any repairs or material purchases that have not received prior written approval from Mendota.
NOTE: Minor warping of certain parts or discoloration is normal and is not a defect covered by this warranty. Major warping of parts can be caused by over-firing of your Mendota Fireplace. Over-firing above rated nameplate specification is as contrary to the manufacturer's instructions and may void this warranty.
5. This warranty may not be extended by our representatives or any third party in any manner. The company neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this Mendota product.
6. Mendota may at its discretion, fully discharge all obligations of this warranty by refunding the wholesale price of the defective part(s).
7. All other warranties - expressed or implied - with respect to the product, its components and accessories, or any obligation/liabilities on the part of the company are hereby expressly excluded. Products made by other manufacturers, sold with the Fireplace or thereafter, are not covered by this limited warranty. The use of unauthorized components will make this warranty null and void.
3. This warranty shall be effective only if the original purchaser of the Mendota appliance is registered with Mendota Division within thirty
(30) days of the date of purchase. Such registration or the failure to register shall not be deemed to create any obligation or liability by the manufacturer and this warranty with its conditions and limitations shall be the only procedure for obtaining any rights against the manufacturer and expresses the sole obligation and responsibilities of the manufacturer which are offered to the original purchaser and accepted upon purchase of the appliance.
4. Mendota Division, reserves the right to make changes at any time without notice, in design, material, specifications, prices and the right to discontinue styles and products.
5. Some states do not allow the exclusion of limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
62
Document #85-03-00844
Johnson Gas Appliance Company
520 E Avenue N.W. - Cedar Rapids, IA 52405
Mendota Hearth Division
WEBPAGE: www.johnsongas.com or www.mendotahearth.com

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Co-axial direct vent
- Sealed combustion system
- Realistic log set with ember bed
- Remote control with thermostat function
- Dual blower system for heat distribution
- Safety features including pilot generator and millivolt system
- Easy installation and maintenance
- High efficiency heating
- Easy-to-use controls
- Multiple venting options