VFD-VL
Wiring
Brake resistor
(optional)
* EPS
MC
NFB
Recommended Circuit
when power supply
is turned OFF by a
OFF
fault output
Factory setting:
SINK Mode
*
Factory
setting
SA
MC
ON
R(L1)
S(L2)
T(L3)
Don't apply the mains
voltage directly to above
terminals
E
RB
RC
FWD
REV
MI1
MI2
MI3
multifunction
terminals
MI4
MI5
MI6
MI7
MI8
COM
E
-10V
Main circuit (power) terminals
*
*
*
VP
0V
A
A
B
B
Z
Z
VP
0V
A/O
A/O
B/O
B/O
Z/O
Z/O
MRA
MRC
+10V
MO1
Master Frequency
-10 to 10V 47K
MO2
Power supply
-10V 20mA
Multi-function contact
output 1 (Relay)
240VAC 3A
120VAC 3A
24VDC 3A
factory setting:
fault indication
V
IM/PM
E
AUI1/AUI2
A 4~20mA
Motor
W
W(T3)
Power supply
+10V 20mA
Please refer to user
manual for wiring
of SINK mode and
SOURCE mode.
U
U(T1)
V(T2)
MC
FWD/STOP
REV/STOP
Multi-step 1
Multi-step 2
Multi-step 3
Multi-step 4
No function
No function
No function
No function
Digital Signal Common
B2
+1 +2/B1
PG Card (optional)
R
S
T
-
+
Fuse/NFB(No Fuse Breaker)
MCM
E
ACI
123456
ACM
RA
RB
PG
Line driver
incremental encoder
PG Card (optional)
EMVL-PGABL
EMVL-PGABO
EMVL-PGH01
Multi-function contact output 2 (Relay)
240VAC 3A
120VAC 3A
24VDC 3A
factory setting:
indicates that it is running
Multi-function contact output 3
(photocoupler)
48VDC 50mA
Multi-function contact output 4
(photocoupler)
Multi-function
Photocoupler Output
1:+EV
2:GND
3:SG4:SG+
5:NC
6:NC
*RS-485
To communicate to PC,
it needs to use converter
(VFD-USB01 or IFD8500).
RC
Control circuit terminals
Shielded leads & Cable
Terminal EPS is emergency power input terminal, refer to user manual for details.
For PG card, refer to user manual for details.
Please download user manual at
http://www.delta.com.tw/product/em/download/download_main.asp?act=3&pid=1&cid=1&tpid=1
3
W
W1
D
H3
H
H1
WARNING
Read the user manual before operation.
Risk of electrical shock.Wait 10 minutes after removing
power before servicing.
Do not connect AC power to output terminals U/T1,
V/T2 and W/T3.
Use proper grounding techniques.
Check to be sure that the voltage of the main AC power
supply satisfies the rated voltage of the Inverter.
1
2
H2
Industrial Automation Headquarters
Delta Electronics, Inc.
Taoyuan Technology Center
No.18, Xinglong Rd., Taoyuan City,
Taoyuan County 33068, Taiwan
TEL: 886-3-362-6301 / FAX: 886-3-371-6301
Asia
Delta Electronics (Jiangsu) Ltd.
Wujiang Plant 3
1688 Jiangxing East Road,
Wujiang Economic Development Zone
Wujiang City, Jiang Su Province, P.R.C. 215200
TEL: 86-512-6340-3008 / FAX: 86-769-6340-7290
Delta Greentech (China) Co., Ltd.
238 Min-Xia Road, Pudong District,
ShangHai, P.R.C. 201209
TEL: 86-21-58635678 / FAX: 86-21-58630003
Delta Electronics (Japan), Inc.
Tokyo Office
2-1-14 Minato-ku Shibadaimon,
Tokyo 105-0012, Japan
TEL: 81-3-5733-1111 / FAX: 81-3-5733-1211
Delta Electronics (Korea), Inc.
1511, Byucksan Digital Valley 6-cha, Gasan-dong,
Geumcheon-gu, Seoul, Korea, 153-704
TEL: 82-2-515-5303 / FAX: 82-2-515-5302
Delta Electronics Int’l (S) Pte Ltd.
4 Kaki Bukit Ave 1, #05-05, Singapore 417939
TEL: 65-6747-5155 / FAX: 65-6744-9228
Delta Electronics (India) Pvt. Ltd.
Plot No 43 Sector 35, HSIIDC
Gurgaon, PIN 122001, Haryana, India
TEL : 91-124-4874900 / FAX : 91-124-4874945
Americas
Delta Products Corporation (USA)
Raleigh Office
P.O. Box 12173,5101 Davis Drive,
Research Triangle Park, NC 27709, U.S.A.
TEL: 1-919-767-3800 / FAX: 1-919-767-8080
Delta Greentech (Brasil) S.A.
Sao Paulo Office
Rua Itapeva, 26 - 3° andar Edificio Itapeva One-Bela Vista
01332-000-São Paulo-SP-Brazil
TEL: 55 11 3568-3855 / FAX: 55 11 3568-3865
Europe
Deltronics (The Netherlands) B.V.
Eindhoven Office
De Witbogt 20, 5652 AG Eindhoven, The Netherlands
TEL: 31-40-2592850 / FAX: 31-40-2592851
*We reserve the right to change the information in this catalogue without prior notice.
Delta_VFD-VL_C_EN_20140315
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement