Keylock7700 IEC

Keylock7700 IEC
TEST REPORT
IEC 60950-1
Information technology equipment – Safety –
Part 1: General requirements
Report Number. ............................. :
UNI2015122413SR-01
Date of issue .................................. :
2015-12-22
Total number of pages ....................
42
Tested by (+ signature)
Steven
Compiled by (+ signature)
Hoffer
Approved by (+ signature)
YangDongping
Applicant’s name ........................... :
TIMETEC COMPUTING SDN BHD
Address .......................................... :
No.6, 8 & 10 Jalan BK 3/2, Bandar Kinrara 47180 Puchong,
Selangor, Malaysia.
Test specification:
Standard ......................................... :
IEC 60950-1:2005+A1:2009+A2:2013
Test procedure ............................... :
IEC test report
Non-standard test method ............ :
N/A
Test Report Form No. .................... :
IEC60950_1F
Test Report Form(s) Originator .... :
SGS Fimko Ltd
Master TRF ..................................... :
Dated 2014-02
Copyright © 2014 IEC System of Conformity Assessment Schemes for Electrotechnical Equipment
and Components (IECEE System). All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.
General disclaimer:
The test results presented in this report relate only to the object tested.
Test item description ....................... :
KEYLOCK
Trade Mark ........................................ :
FINGERTEC
Manufacturer ..................................... :
Same as applicant
Model/Type reference....................... :
7700
Ratings............................................... :
Input: 12VDC , 1.5A
Page 2 of 42
Testing procedure and testing location:
Testing Laboratory:
Testing location/ address ............................ :
Associated Testing Laboratory:
Testing location/ address ............................ :
Tested by (name + signature) ...................... :
Approved by (name + signature) ................. :
Testing procedure: TMP/CTF Stage 1:
Testing location/ address ............................ :
Tested by (name + signature) ...................... :
Approved by (name + signature) ................. :
Testing procedure: WMT/CTF Stage 2:
Testing location/ address ............................ :
Tested by (name + signature) ...................... :
Witnessed by (name + signature) ............... :
Approved by (name + signature) ................. :
Testing procedure:
SMT/CTF Stage 3 or 4:
Testing location/ address ............................ :
Tested by (name + signature) ...................... :
Witnessed by (name + signature) ............... :
Approved by (name + signature) ................. :
Supervised by (name + signature) .............. :
TRF No. IEC60950_1F
Report No. : UNI2015122413SR-01
Page 3 of 42
Report No. : UNI2015122413SR-01
List of Attachments (including a total number of pages in each attachment):
1, Photo attachments.(3 pages)
Summary of testing:
Tests performed (name of test and test
clause):
1
General
2
Protection from hazards
3
Wiring, connections and supply
4
Physical requirements
Abnormal operating and fault
conditions
5
Testing location:
Laboratory of Shenzhen United Testing Technology
Co., Ltd.
5/F., Building 7, Xinyuan Industrial Park, Xili,
Nanshan District, Shenzhen, Guangdong, China
Summary of compliance with National Differences:
List of countries addressed
Saudi Arabia national differences. (No differences)
The product fulfils the requirements of IEC 60950-1:2005+A1:2009+A2:2013.
TRF No. IEC60950_1F
Page 4 of 42
Copy of marking plate:
The artwork below may be only a draft.
FINGERTEC
KEYLOCK
Model: 7700
Input: 12VDC, 1.5A
Made in Malaysia
TRF No. IEC60950_1F
Report No. : UNI2015122413SR-01
Page 5 of 42
Report No. : UNI2015122413SR-01
Test item particulars...................................................:
[] transportable
Equipment mobility.................................................: [] movable [] hand-held
[x] stationary [] for building-in [] direct plug-in
Connection to the mains........................................: [] pluggable equipment [] type A [] type B
[] permanent connection
[] detachable power supply cord
[] non-detachable power supply cord
[x] not directly connected to the mains
Operating condition................................................: [x] continuous
[] rated operating / resting time:
Access location ......................................................: [x] operator accessible
[] restricted access location
Over voltage category (OVC) ................................: [] OVC I
[] other:
[x] OVC II
[] OVC III
Mains supply tolerance (%) or absolute mains
supply values .........................................................: N/A
Tested for IT power systems .................................: [] Yes
[x] No
IT testing, phase-phase voltage (V) ......................: N/A
Class of equipment ................................................: [] Class I [] Class II
[] Not classified
[X] Class III
Considered current rating of protective device as
part of the building installation (A) .......................: 16A
Pollution degree (PD) .............................................: [] PD 1
[x] PD 2
[] PD 3
IP protection class ..................................................: IP20
Altitude during operation (m) ................................: Up to 2000m
Altitude of test laboratory (m) ...............................: Below 2000m
Mass of equipment (kg) .........................................: Approx.3.253kg
Possible test case verdicts:
- test case does not apply to the test object ........... : N/A
- test object does meet the requirement.................. : P (Pass)
- test object does not meet the requirement ........... : F (Fail)
Testing.......................................................................... :
Date of receipt of test item ........................................ : 2015-12-08
Date (s) of performance of tests ............................... : 2015-12-09 to 2015-12-21
TRF No. IEC60950_1F
[] OVC IV
Page 6 of 42
Report No. : UNI2015122413SR-01
General remarks:
"(See Enclosure #)" refers to additional information appended to the report.
"(See appended table)" refers to a table appended to the report.
Throughout this report a
comma /
point is used as the decimal separator.
The related applicable OSM decisionshave been considered and therequirements found fulfilled.
Determination of the test result includes consideration of measurement uncertainty from the test
equipment and methods.
Manufacturer’s Declaration per sub-clause 4.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory has
been provided ............................................................... :
Yes
Not applicable
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies) .......................... : Same as applicant
General product information:
The product is Class III KEYLOCK intended to be in indoor use, electronic components mounted on PCB,
External enclosure is metal and plastic material of min.V-1 grade, secured by screw
Maximum recommended ambient (Tmra): 40°C
Abbreviations used in the report:
- normal conditions
- functional insulation
- double insulation
- between parts of opposite
polarity
N.C.
OP
DI
- single fault conditions
- basic insulation
- supplementary insulation
S.F.C
BI
SI
BOP
- reinforced insulation
RI
Indicate used abbreviations (if any)
TRF No. IEC60950_1F
Page 7 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
1
GENERAL
P
1.5
Components
P
1.5.1
General
P
Comply with IEC 60950-1 or relevant component
standard
(see appended tables 1.5.1)
P
1.5.2
Evaluation and testing of components
Certified components are used
in accordance with their ratings,
certifications and they comply
with applicable parts of this
standard.
Components not certified are
used in accordance with their
ratings and they comply with
applicable parts of IEC 60950-1
and the relevant component
standard.
Components, for which no
relevant IEC-standard exists,
have been tested under the
conditions occurring in the
equipment, using applicable
parts of IEC 60950-1.
P
1.5.3
Thermal controls
No thermal control.
N/A
1.5.4
Transformers
Class III equipment
N/A
1.5.5
Interconnecting cables
1.5.6
Capacitors bridging insulation
N/A
1.5.7
Resistors bridging insulation
N/A
1.5.7.1
Resistors bridging functional, basic or
supplementary insulation
N/A
1.5.7.2
Resistors bridging double or reinforced insulation
between a.c. mains and other circuits
N/A
1.5.7.3
Resistors bridging double or reinforced insulation
between a.c. mains and antenna or coaxial cable
N/A
1.5.8
Components in equipment for IT power systems
N/A
1.5.9
Surge suppressors
1.5.9.1
General
N/A
N/A
1.5.9.2
Protection of VDRs
N/A
1.5.9.3
Bridging of functional insulation by a VDR
N/A
1.5.9.4
Bridging of basic insulation by a VDR
N/A
1.5.9.5
Bridging of supplementary, double or reinforced
insulation by a VDR
N/A
TRF No. IEC60950_1F
P
Page 8 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
1.6
Power interface
1.6.1
AC power distribution systems
Not directly connected to the
mains
1.6.2
Input current
(see appended table 1.6.2)
1.6.3
Voltage limit of hand-held equipment
The equipment is not handheld
equipment
1.6.4
Neutral conductor
1.7
Marking and instructions
1.7.1
Power rating and identification markings
The required marking is located
on the outside surface of the
equipment.
P
1.7.1.1
Power rating marking
See below
P
P
N/A
P
N/A
N/A
P
Multiple mains supply connections.........................: Only one mains supply
connections.
N/A
Rated voltage(s) or voltage range(s) (V) ...............: 12V
P
Symbol for nature of supply, for d.c. only ...............:
P
DC
Rated frequency or rated frequency range (Hz) ....:
1.7.1.2
Verdict
N/A
Rated current (mA or A) ........................................: 1.5A
P
Identification markings
P
See below
Manufacturer’s name or trade-mark or
TIMETEC COMPUTING SDN
identification mark ..................................................: BHD
P
Model identification or type reference ...................: 7700
P
Symbol for Class II equipment only .......................:
N/A
Other markings and symbols .................................:
N/A
1.7.1.3
Use of graphical symbols
N/A
1.7.2
Safety instructions and marking
1.7.2.1
General
1.7.2.2
Disconnect devices
1.7.2.3
Overcurrent protective device
N/A
1.7.2.4
IT power distribution systems
N/A
1.7.2.5
Operator access with a tool
N/A
1.7.2.6
Ozone
The equipment does not
produce Ozone.
N/A
1.7.3
Short duty cycles
The equipment is designed for
continuous operation.
N/A
1.7.4
Supply voltage adjustment ...................................:
Full range voltage design, no
Voltage adjustment.
N/A
TRF No. IEC60950_1F
See below.
P
P
Not directly connected to the
mains
N/A
Page 9 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
N/A
Methods and means of adjustment; reference to
installation instructions .........................................:
1.7.5
Power outlets on the equipment ...........................:
1.7.6
Fuse identification (marking, special fusing
characteristics, crossreference) ..............................:
1.7.7
Wiring terminals
No such terminals
N/A
1.7.7.1
Protective earthing and bonding terminals
............................................................... ...............:
Class III equipment
N/A
1.7.7.2
Terminals for a.c. mains supply conductors
The equipment is not
permanently connected or
provided with a non-detachable
power supply cord.
N/A
1.7.7.3
Terminals for d.c. mains supply conductors
The equipment is not supplied
from d.c mains.
N/A
1.7.8
Controls and indicators
See below
N/A
1.7.8.1
Identification, location and marking ........................: No controls affecting safety
N/A
1.7.8.2
Colours ..................................................................: No indicators with colours
where safety is involved
N/A
1.7.8.3
Symbols according to IEC 60417............................:
N/A
1.7.8.4
Markings using figures ..........................................:
N/A
1.7.9
Isolation of multiple power sources ........................: Only one connection supplying
hazardous voltages and energy
levels to the equipment.
N/A
1.7.10
Thermostats and other regulating devices .............: No thermostats or other
regulating devices.
N/A
1.7.11
Durability
1.7.12
Removable parts
N/A
1.7.13
Replaceable batteries .......................................... :
N/A
Language(s) ........................................................ :

1.7.14
Equipment for restricted access locations ............ :
N/A
2
PROTECTION FROM HAZARDS
TRF No. IEC60950_1F
No standard power outlet.
N/A
N/A
The marking plate was
subjected to the permanence of
marking test. The marking plate
was rubbed with cloth soaked
with water for 15s and then
again for 15s with the cloth
soaked with petroleum spirit.
After this test there was no
damage to the marking plate.
The marking on the label did
not fade.
P
P
Page 10 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
2.1
Protection from electric shock and energy hazards
P
2.1.1
Protection in operator access areas
P
2.1.1.1
Access to energized parts
Class III equipment only
Verdict
Test by inspection ..................................................:
N/A
N/A
Test with test finger (Figure 2A) ............................:
N/A
Test with test pin (Figure 2B) .................................:
N/A
Test with test probe (Figure 2C) ............................: No TNV circuits within the
equipment.
N/A
2.1.1.2
Battery compartments
No TNV circuits within the
equipment
N/A
2.1.1.3
Access to ELV wiring
No ELV circuit
N/A
Working voltage (Vpeak or Vrms); minimum
distance through insulation (mm)
(see appended tables 2.10.2
and 2.10.5)
2.1.1.4
Access to hazardous voltage circuit wiring
No internal wiring at hazardous
voltage circuit accessible to
the operator.
2.1.1.5
Energy hazards .....................................................: No energy hazard in operator
access area. Checked by
means of the test finger.
2.1.1.6
Manual controls
2.1.1.7
Discharge of capacitors in equipment
No conductive shafts of
operating knobs, handles,
levers and the like in operator
access areas.
Energy hazards – d.c. mains supply
N/A
P
N/A
N/A

Measured voltage (V); time-constant (s) ................:
2.1.1.8

Not connected to DC mains
supply
N/A
a) Capacitor connected to the d.c. mains supply ..:
N/A
b) Internal battery connected to the d.c. mains
supply :
N/A
2.1.1.9
Audio amplifiers .....................................................:
N/A
2.1.2
Protection in service access areas
N/A
2.1.3
Protection in restricted access locations
N/A
2.2
SELV circuits
2.2.1
General requirements
2.2.2
Voltages under normal conditions (V) .................. : 12VDC
P
2.2.3
Voltages under fault conditions (V) ...................... : 12VDC
P
TRF No. IEC60950_1F
P
SELV limits are not exceeded
under normal condition and
after a single fault.
P
Page 11 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
2.2.4
Connection of SELV circuits to other circuits ...... :
SELV circuits are only
connected to other SELV
circuits.
2.3
TNV circuits
2.3.1
Limits
Verdict
P
N/A
No TNV circuits within the
equipment.
N/A
Type of TNV circuits .............................................. :

2.3.2
Separation from other circuits and from accessible
parts
N/A
2.3.2.1
General requirements
N/A
2.3.2.2
Protection by basic insulation
N/A
2.3.2.3
Protection by earthing
N/A
2.3.2.4
Protection by other constructions ......................... :
N/A
2.3.3
Separation from hazardous voltages
N/A

Insulation employed............................................... :
2.3.4
Connection of TNV circuits to other circuits
N/A

Insulation employed............................................... :
2.3.5
Test for operating voltages generated externally
N/A
2.4
Limited current circuits
N/A
2.4.1
General requirements
N/A
2.4.2
Limit values
N/A
Frequency (Hz) .......................................................:

Measured current (mA)...........................................:

Measured voltage (V) .............................................:

Measured circuit capacitance (nF or µF) ................:

2.4.3
Connection of limited current circuits to other
circuits
N/A
2.5
Limited power sources
N/A
a) Inherently limited output
N/A
b) Impedance limited output
(see appended table 2.5)
N/A
N/A
c) Regulating network or IC current limiter, limits
output under normal operating and single fault
condition
Use of integrated circuit (IC) current limiters
(See Annex CC)
N/A
d) Overcurrent protective device limited output
(see appended table 2.5)
N/A
TRF No. IEC60950_1F
Page 12 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
Max. output voltage (V), max. output current (A),
max. apparent power (VA)..................................... :

Current rating of overcurrent protective device (A) .:

2.6
Provisions for earthing and bonding
2.6.1
Protective earthing
2.6.2
Functional earthing
N/A
Class III equipment
N/A
N/A

Use of symbol for functional earthing …................:
2.6.3
Protective earthing and protective bonding
conductors
N/A
2.6.3.1
General
N/A
2.6.3.2
Size of protective earthing conductors
N/A
2

Rated current (A), cross-sectional area (mm ),
AWG ...................................................................... :
2.6.3.3
Size of protective bonding conductors
N/A
2
Rated current (A), cross-sectional area (mm ),
AWG ...................................................................... :

Protective current rating (A), cross-sectional area
(mm2), AWG .......................................................... :

2.6.3.4
Resistance of earthing conductors and their
terminations; resistance (), voltage drop (V), test
current (A), duration (min) ..................................... :
N/A
2.6.3.5
Colour of insulation ................................................ :
N/A
2.6.4
Terminals
N/A
2.6.4.1
General
N/A
2.6.4.2
Protective earthing and bonding terminals
N/A

Rated current (A), type, nominal thread diameter
(mm) ...................................................................... :
2.6.4.3
Separation of the protective earthing conductor
from protective bonding conductors
N/A
2.6.5
Integrity of protective earthing
N/A
2.6.5.1
Interconnection of equipment
N/A
.
2.6.5.2
Components in protective earthing conductors and
protective bonding conductors
2.6.5.3
Disconnection of protective earth
N/A
2.6.5.4
Parts that can be removed by an operator
N/A
2.6.5.5
Parts removed during servicing
N/A
2.6.5.6
Corrosion resistance
N/A
2.6.5.7
Screws for protective bonding
N/A
TRF No. IEC60950_1F
N/A
Page 13 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
2.6.5.8
Reliance on telecommunication network or cable
distribution system
N/A
2.7
Overcurrent and earth fault protection in primary circuits
N/A
2.7.1
Basic requirements
N/A
Class III equipment
Verdict
N/A
Instructions when protection relies on building
installation
2.7.2
Faults not simulated in 5.3.7
—
2.7.3
Short-circuit backup protection
N/A
2.7.4
Number and location of protective devices .......... :
N/A
2.7.5
Protection by several devices
N/A
2.7.6
Warning to service personnel ................................ :
N/A
2.8
Safety interlocks
N/A
2.8.1
General principles
2.8.2
Protection requirements
N/A
2.8.3
Inadvertent reactivation
N/A
2.8.4
Fail-safe operation
N/A
Protection against extreme hazard
N/A
2.8.5
Moving parts
N/A
2.8.6
Overriding
N/A
2.8.7
Switches, relays and their related circuits
N/A
2.8.7.1
Separation distances for contact gaps and their
related circuits (mm) .............................................. :
N/A
2.8.7.2
Overload test
N/A
2.8.7.3
Endurance test
N/A
2.8.7.4
Electric strength test
2.8.8
Mechanical actuators
N/A
2.9
Electrical insulation
P
2.9.1
Properties of insulating materials
2.9.2
Humidity conditioning
No safety interlocks or similar
devices within the equipment
(see appended table 5.2)
Neither natural rubber,
materials containing asbestons
nor hygroscopic materials are
used as insulation. No driving
belts or coupling used.
Carried out for 120 hrs.
Relative humidity (%), temperature (°C) ............... : 95%, 40°C (according to
client’s requirement)
TRF No. IEC60950_1F
N/A
N/A
P
P

Page 14 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
2.9.3
Grade of insulation
Adequate levels of safety
insulation were provided and
maintained to comply with the
requirements of this standard
2.9.4
Separation from hazardous voltages
See below
Method(s) used ..................................................... : Method 1 used
Verdict
P
N/A

N/A
2.10
Clearances, creepage distances and distances through insulation
2.10.1
General
2.10.1.1
Frequency ..............................................................: Considered.
N/A
2.10.1.2
Pollution degrees ...................................................: Pollution Degree 2.
N/A
2.10.1.3
Reduced values for functional insulation
The is no requirement for
functional insulation
N/A
2.10.1.4
Intervening unconnected conductive parts
Considered
2.10.1.5
Insulation with varying dimensions
No such transfomer used.
N/A
2.10.1.6
Special separation requirements
Special separation is not used.
N/A
2.10.1.7
Insulation in circuits generating starting pulses
The circuit will not generate
starting pulse.
N/A
2.10.2
Determination of working voltage
N/A
2.10.2.1
General
2.10.2.2
RMS working voltage

N/A
2.10.2.3
Peak working voltage
N/A
2.10.3
Clearances
N/A
2.10.3.1
General
2.10.3.2
Mains transient voltages
N/A
a) AC mains supply ...............................................: Not directly connected to the a
c mains
N/A
b) Earthed d.c. mains supplies ..............................: Not directly connected to the d
c mains
N/A
c) Unearthed d.c. mains supplies ..........................: Not directly connected to the d
c mains
N/A
d) Battery operation ...............................................:
N/A
See below.


—
2.10.3.3
Clearances in primary circuits
(see appended table 2.10.3 and
2.10.4)
N/A
2.10.3.4
Clearances in secondary circuits
Only the functional insulation in
secondary circuits complied
with clause 5.3.4.
N/A
2.10.3.5
Clearances in circuits having starting pulses
TRF No. IEC60950_1F
N/A
Page 15 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
2.10.3.6
Transients from a.c. mains supply .........................:
Not connected to a c mains
supply.
N/A
2.10.3.7
Transients from d.c. mains supply .........................: Not connected to d.c mains
supply.
N/A
2.10.3.8
Transients from telecommunication networks and
Not connected to
cable distribution systems .....................................: telecommunication networks
and cable distribution systems.
N/A
2.10.3.9
Measurement of transient voltage levels
See below.
a) Transients from a mains supply
Measurement not relevant.
—
N/A
For an a.c. mains supply .......................................:
N/A
For a d.c. mains supply .........................................:
N/A
b) Transients from a telecommunication network :
Not connected to
telecommunication networks.
N/A
2.10.4
Creepage distances
See below.
N/A
2.10.4.1
General
Considered.
N/A
2.10.4.2
Material group and comparative tracking index
See below.
N/A
CTI tests .................................................................: Material group IIIb is assumed
to be used

2.10.4.3
Minimum creepage distances
(see appended table 2.10.3 and
2.10.4)
N/A
2.10.5
Solid insulation
See below.
N/A
2.10.5.1
General
Considered.
N/A
2.10.5.2
Distances through insulation
(see appended table 2.10.5)
N/A
2.10.5.3
Insulating compound as solid insulation
N/A
2.10.5.4
Semiconductor devices
N/A
2.10.5.5.
Cemented joints
2.10.5.6
Thin sheet material – General
N/A
2.10.5.7
Separable thin sheet material
N/A
(see appended table 2.10.3 and
2.10.4)
Number of layers (pcs) ...........................................: 2 layers (test 1 layers)
N/A

2.10.5.8
Non-separable thin sheet material
N/A
2.10.5.9
Thin sheet material – standard test procedure
N/A
Electric strength test
2.10.5.10
(see appended table 2.10.5)
Thin sheet material – alternative test procedure
Electric strength test

N/A
(see appended table 2.10.5)

2.10.5.11
Insulation in wound components
N/A
2.10.5.12
Wire in wound components
N/A
Working voltage .....................................................:
N/A
TRF No. IEC60950_1F
Page 16 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
2.10.5.13
2.10.5.14
Requirement + Test
Result - Remark
Verdict
a) Basic insulation not under stress ......................:
N/A
b) Basic, supplementary, reinforced insulation ......:
N/A
c) Compliance with Annex U .................................:
N/A
Two wires in contact inside wound component;
angle between 45 and 90 ...................................:
N/A
Wire with solvent-based enamel in wound
components
No wire with solvent-based
enamel in wound components.
Electric strength test
(see appended table 2.10.5)
N/A

Routine test
N/A
Additional insulation in wound components
N/A
Working voltage .....................................................:
N/A
- Basic insulation not under stress ........................:
N/A
- Supplementary, reinforced insulation ..................:
N/A
2.10.6
Construction of printed boards
See below.
N/A
2.10.6.1
Uncoated printed boards
(see appended table 2.10.3 and
2.10.4)
N/A
2.10.6.2
Coated printed boards
(see appended table 2.10.3 and
2.10.4)
N/A
2.10.6.3
Insulation between conductors on the same inner
surface of a printed board
(see appended table 2.10.3 and
2.10.4)
N/A
2.10.6.4
Insulation between conductors on different layers
of a printed board
Distance through insulation
N/A
(see appended table 2.10.5)
Number of insulation layers (pcs) ...........................:
N/A
N/A
2.10.7
Component external terminations
Coatings not used over
terminations to increase
effective creepage and
clearance distances.
N/A
2.10.8
Tests on coated printed boards and coated
components
No special coating in order to
reduce distance.
N/A
2.10.8.1
Sample preparation and preliminary inspection
N/A
2.10.8.2
Thermal conditioning
N/A
2.10.8.3
Electric strength test
2.10.8.4
Abrasion resistance test
N/A
2.10.9
Thermal cycling
N/A
2.10.10
Test for Pollution Degree 1 environment and
insulating compound
N/A
2.10.11
Tests for semiconductor devices and cemented
joints
N/A
TRF No. IEC60950_1F
(see appended table 5.2)
N/A
Page 17 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
2.10.12
Enclosed and sealed parts
3
WIRING, CONNECTIONS AND SUPPLY
P
3.1
General
P
3.1.1
Current rating and overcurrent protection
Adequate cross sectional
areas on wiring.
P
3.1.2
Protection against mechanical damage
Wireways are smooth and free
from edges. Wires are
adequately fixed to prevent
excessive strain on wire and
terminals and avoiding damage
to the insulation of the
conductors.
P
3.1.3
Securing of internal wiring
Internal wiring is secured
against excessive strain,
loosening of terminals and
damage to the conductor
insulation.
P
3.1.4
Insulation of conductors
Insulation on internal
conductors is considered to be
of adequate quality and suitable
for the application
N/A
3.1.5
Beads and ceramic insulators
No beads or similar ceramic
insulators on conductors.
N/A
3.1.6
Screws for electrical contact pressure
3.1.7
Insulating materials in electrical connections
3.1.8
Self-tapping and spaced thread screws
3.1.9
Termination of conductors
N/A
N/A
No contact pressure through
insulating material.
P
N/A
Terminations cannot become
displaced so that clearances
and creepage distances can
be reduced.
N/A
10 N pull test
N/A
3.1.10
Sleeving on wiring
N/A
3.2
Connection to a mains supply
N/A
3.2.1
Means of connection
3.2.1.1
Connection to an a.c. mains supply
3.2.1.2
Connection to a d.c. mains supply
3.2.2
Multiple supply connections
TRF No. IEC60950_1F
See below
N/A
N/A
The equipment is not for
connection to a d.c. mains
supply.
N/A
N/A
Page 18 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
3.2.3
Permanently connected equipment
The equipment is not intended
for permanent connection to the
mains.
Verdict
N/A

Number of conductors, diameter of cable and
conduits (mm) ....................................................... :
3.2.4
Appliance inlets
3.2.5
Power supply cords
N/A
3.2.5.1
AC power supply cords
N/A
Not directly connected to the
mains

Type ...................................................................... :
2

Rated current (A), cross-sectional area (mm ),
AWG ..................................................................... :
3.2.5.2
DC power supply cords
3.2.6
Cord anchorages and strain relief
N/A
The equipment is not for
connecting to d.c. mains.
N/A
N/A
Mass of equipment (kg), pull (N) ......................... :

Longitudinal displacement (mm) .......................... : Longitudinal displacement less
than 2mm

3.2.7
Protection against mechanical damage
3.2.8
Cord guards
N/A
No moving when it is intended
to be operated
N/A
Diameter or minor dimension D (mm); test mass (g)
............................................................................... :

Radius of curvature of cord (mm) .......................... :

3.2.9
Supply wiring space
N/A
3.3
3.3.1
Wiring terminals for connection of external conductors
Not directly connected to the
Wiring terminals
mains
N/A
N/A
3.3.2
Connection of non-detachable power supply cords
N/A
3.3.3
Screw terminals
N/A
3.3.4
Conductor sizes to be connected
N/A
Rated current (A), cord/cable type, cross-sectional
area (mm2) ............................................................. :
3.3.5
Wiring terminal sizes
Rated current (A), type, nominal thread diameter
(mm) ..................................................................... :

N/A

3.3.6
Wiring terminal design
N/A
3.3.7
Grouping of wiring terminals
N/A
TRF No. IEC60950_1F
Page 19 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
3.3.8
Stranded wire
N/A
3.4
Disconnection from the mains supply
N/A
3.4.1
General requirement
N/A
3.4.2
Disconnect devices
N/A
3.4.3
Permanently connected equipment
3.4.4
Parts which remain energized
N/A
3.4.5
Switches in flexible cords
N/A
3.4.6
Number of poles – single-phase and d.c.
equipment
N/A
3.4.7
Number of poles – three-phase equipment
N/A
3.4.8
Switches as disconnect devices
N/A
3.4.9
Plugs as disconnect devices
N/A
3.4.10
Interconnected equipment
N/A
3.4.11
Multiple power sources
N/A
3.5
Interconnection of equipment
P
3.5.1
General requirements
P
Not directly connected to the
mains
Verdict
N/A
3.5.2
Considered.
Types of interconnection circuits .......................... : SELV circuit.
3.5.3
ELV circuits as interconnection circuits
3.5.4
Data ports for additional equipment
P
4
PHYSICAL REQUIREMENTS
P
4.1
Stability
N/A
Angle of 10
N/A
Test force (N) .........................................................:
N/A
N/A
P
4.2
Mechanical strength
4.2.1
General
Complies with the requirement
also after tests described below
are applied.
Rack-mounted equipment.
No rack-mounted equipment.
4.2.2
Steady force test, 10 N
No hazard, ref. Comment in
appended table 2.10.3 – 2.10.4
4.2.3
Steady force test, 30 N
TRF No. IEC60950_1F
P
P
N/A
P
N/A
Page 20 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
4.2.4
Steady force test, 250 N
No hazards. The test is
performed at plastic enclosure.
4.2.5
Impact test
N/A
Fall test
N/A
Swing test
N/A
4.2.6
Drop test; height (mm) ...........................................:
N/A
4.2.7
Stress relief test
4.2.8
Cathode ray tubes
No hazardous parts in the
equipment
No cathode ray tubes provided
Verdict
P
N/A
N/A
Picture tube separately certified ............................:
N/A
4.2.9
High pressure lamps
N/A
4.2.10
Wall or ceiling mounted equipment; force (N) .......: 50N
P
4.3
Design and construction
P
4.3.1
Edges and corners
All edges and corners are
rounded and/or smoothed.
P
4.3.2
Handles and manual controls; force (N) ............. :
50N
P
4.3.3
Adjustable controls
No hazardous adjustable
controls.
4.3.4
Securing of parts
No loosening of parts impairing
creepage distances or
clearances is likely to occur.
4.3.5
Connection by plugs and sockets
N/A
4.3.6
Direct plug-in equipment
N/A
N/A
P
Torque ..................................................................:

Compliance with the relevant mains plug standard
...............................................................................:
N/A
4.3.7
Heating elements in earthed equipment
4.3.8
Batteries
N/A
N/A
- Overcharging of a rechargeable battery
N/A
- Unintentional charging of a non-rechargeable
battery
(see appended table 4.3.8)
N/A
- Reverse charging of a rechargeable battery
(see appended table 4.3.8)
N/A
N/A
- Excessive discharging rate for any battery
4.3.9
Oil and grease
4.3.10
Dust, powders, liquids and gases
TRF No. IEC60950_1F
Insulation in intended use not
considered to be exposed to oil
or grease.
The equipment does not
produce dust or use powders,
liquids and gases in the
equipment.
N/A
N/A
Page 21 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
4.3.11
Containers for liquids or gases
No container for liquids or
gases used
N/A
4.3.12
Flammable liquids .................................................:
The equipment does not
contain flammable liquid
N/A
Quantity of liquid (l) ...............................................:
N/A
Flash point (C) .....................................................:
N/A
4.3.13
Radiation
N/A
4.3.13.1
General
N/A
4.3.13.2
Ionizing radiation
4.3.13.3
The equipment does not
generate ionizing radiation.
N/A
Measured radiation (Pa/kg) ..................................:

Measured high-voltage (Kv) .................................:

Measured focus voltage (Kv) ................................:

CRT markings .......................................................:

Effect of ultraviolet (UV) radiation on materials
The equipment does not
produce significant UV
radiation.
N/A
N/A
Part, property, retention after test, flammability
classification .........................................................:
4.3.13.4
Human exposure to ultraviolet (UV) radiation ......:
4.3.13.5
Lasers (including laser diodes) and LEDs
N/A
4.3.13.5.1
Lasers (including laser diodes)
N/A
The equipment does not
produce significant UV
radiation.
N/A
Laser class ............................................................:

4.3.13.5.2
Light emitting diodes (LEDs)

4.3.13.6
Other types ...........................................................:
4.4
Protection against hazardous moving parts
4.4.1
General
4.4.2
Protection in operator access areas .................... :
Household and home/office document/media
shredders
The equipment does not
generate other types of
radiation.
N/A
N/A
No hazardous moving parts
within the equipment
N/A
N/A
(see Annex EE)
N/A
4.4.3
Protection in restricted access locations ............. :
N/A
4.4.4
Protection in service access areas
N/A
4.4.5
Protection against moving fan blades
N/A
TRF No. IEC60950_1F
Page 22 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
4.4.5.1
General
N/A
Not considered to cause pain or injury. A)…………:
N/A
Is considered to cause pain, not injury.
B) …………:
N/A
Considered to cause injury.
C) …………:
N/A
Protection for users
N/A
Use of symbol or warning …………………………..:
N/A
Protection for service persons
N/A
Use of symbol or warning …………………………..:
N/A
4.4.5.2
4.4.5.3
Result - Remark
Verdict
4.5
Thermal requirements
P
4.5.1
General
P
4.5.2
Temperature tests
P
Normal load condition per Annex L ..................... :

4.5.3
Temperature limits for materials
(see appended table 4.5)
P
4.5.4
Touch temperature limits
(see appended table 4.5)
P
4.5.5
Resistance to abnormal heat ............................... :
(see appended table 4.5.5)
P
4.6
Openings in enclosures
4.6.1
Top and side openings
N/A
No openings

Dimensions (mm) ................................................ :
4.6.2
N/A
Bottoms of fire enclosures
N/A

Construction of the bottomm, dimensions (mm) .. :
4.6.3
Doors or covers in fire enclosures
4.6.4
Openings in transportable equipment
N/A
4.6.4.1
Constructional design measures
N/A
No doors or covers in fire
enclosure.
N/A

Dimensions (mm) ................................................ :
4.6.4.2
Evaluation measures for larger openings
N/A
4.6.4.3
Use of metallized parts
N/A
4.6.5
Adhesives for constructional purposes
N/A
Conditioning temperature (C), time (weeks) ....... :

4.7
Resistance to fire
P
4.7.1
Reducing the risk of ignition and spread of flame
TRF No. IEC60950_1F
Method 1 is used.
P
Page 23 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Method 1, selection and application of components (see appended table 1.5.1)
wiring and materials
Verdict
P
N/A
Method 2, application of all of simulated fault
condition tests
4.7.2
Conditions for a fire enclosure
Refer below.
P
4.7.2.1
Parts requiring a fire enclosure
The fire enclosure cover all
components
P
4.7.2.2
Parts not requiring a fire enclosure
4.7.3
Materials
4.7.3.1
General
Components and materials
have adequate flammability
classification.
See appended table 1.5.1
P
4.7.3.2
Materials for fire enclosures
Min.V-1 for plastic fire
enclosure
P
4.7.3.3
Materials for components and other parts outside
fire enclosures
4.7.3.4
Materials for components and other parts inside
fire enclosures
Materials inside fire enclosure
are minimum V-1 material or
better
P
4.7.3.5
Materials for air filter assemblies
No air filters in the equipment
N/A
4.7.3.6
Materials used in high-voltage components
No parts exceeding 4Kv
N/A
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
5.1
Touch current and protective conductor current
N/A
5.1.1
General
N/A
5.1.2
Configuration of equipment under test (EUT)
5.1.2.1
Single connection to an a.c. mains supply
N/A
5.1.2.2
Redundant multiple connections to an a.c. mains
supply
N/A
5.1.2.3
Simultaneous multiple connections to an a.c. mains
supply
N/A
5.1.3
Test circuit
N/A
5.1.4
Application of measuring instrument
N/A
5.1.5
Test procedure
N/A
5.1.6
Test measurements
N/A
N/A
P
N/A
P

Supply voltage (V) ................................................ :

Measured touch current (Ma) ............................... :

Max. allowed touch current (Ma) .......................... :

Measured protective conductor current (Ma) ....... :

TRF No. IEC60950_1F
Page 24 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict

Max. allowed protective conductor current (Ma) ... :
5.1.7
Equipment with touch current exceeding 3,5 Ma
N/A
5.1.7.1
General ................................................................. :
N/A
5.1.7.2
Simultaneous multiple connections to the supply
N/A
5.1.8
Touch currents to telecommunication networks and Not connected to a
cable distribution systems and from
telecommunication network or
telecommunication networks
cable distribution systems
N/A
5.1.8.1
Limitation of the touch current to a
telecommunication network or to a cable
distribution system
N/A
5.1.8.2
Supply voltage (V) ................................................ :

Measured touch current (Ma) ............................... :

Max. allowed touch current (Ma) .......................... :

Summation of touch currents from
telecommunication networks
N/A
a) EUT with earthed telecommunication ports ..... :
N/A
b) EUT whose telecommunication ports have no
reference to protective earth
N/A
5.2
Electric strength
5.2.1
General
N/A
N/A
5.2.2
Test procedure
5.3
Abnormal operating and fault conditions
5.3.1
Protection against overload and abnormal
operation
See appended table 5.3
5.3.2
Motors
No motor
N/A
5.3.3
Transformers
No transformers
N/A
5.3.4
Functional insulation .............................................. :
No requirement
N/A
5.3.5
Electromechanical components
These equipments don’t have
any electromechanical
components
N/A
5.3.6
Audio amplifiers in ITE .......................................... :
5.3.7
Simulation of faults
see appended table 5.3
5.3.8
Unattended equipment
These equipments don’t
intended for unattended use
5.3.9
Compliance criteria for abnormal operating and
fault conditions
See below
TRF No. IEC60950_1F
(see appended table 5.2)
N/A
P
P
N/A
P
N/A
P
Page 25 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
5.3.9.1
During the tests
5.3.9.2
After the tests
No fire or molten metal
occurred and no deformation of
enclosure during the tests.
No reduction of clearance and
creepage distances. Electric
strength test is made on
functional, supplementary and
reinforced insulation.
6
CONNECTION TO TELECOMMUNICATION NETWORKS
N/A
6.1
Protection of telecommunication network service persons, and users of other
equipment connected to the network, from hazards in the equipment
N/A
6.1.1
Protection from hazardous voltages
N/A
6.1.2
Separation of the telecommunication network from earth
N/A
6.1.2.1
Requirements
N/A
(see appended table 5.2)
Verdict
P
P
Supply voltage (V) ................................................ :

Current in the test circuit (Ma) ............................ :

6.1.2.2
Exclusions ............................................................ :
N/A
6.2
Protection of equipment users from overvoltages on telecommunication
networks
N/A
6.2.1
Separation requirements
N/A
6.2.2
Electric strength test procedure
N/A
6.2.2.1
Impulse test
(see appended table 5.2)
N/A
6.2.2.2
Steady-state test
(see appended table 5.2)
N/A
6.2.2.3
Compliance criteria
N/A
6.3
Protection of the telecommunication wiring system from overheating
N/A
Max. output current (A) ......................................... :

Current limiting method ........................................ :

7
CONNECTION TO CABLE DISTRIBUTION SYSTEMS
N/A
7.1
General
N/A
7.2
Protection of cable distribution system service
persons, and users of other equipment connected to
the system, from hazardous voltages in the
equipment
N/A
7.3
Protection of equipment users from overvoltages on
the cable distribution system
N/A
TRF No. IEC60950_1F
Page 26 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
7.4
Insulation between primary circuits and cable
distribution systems
N/A
7.4.1
General
N/A
7.4.2
Voltage surge test
(see appended table 5.2)
N/A
7.4.3
Impulse test
(see appended table 5.2)
N/A
A
ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE
N/A
A.1
Flammability test for fire enclosures of
movable equipment having a total mass
exceeding 18 kg, and of stationary equipment
(see 4.7.3.2)
N/A
A.1.1
Samples .................................................................:

Wall thickness (mm) ..............................................:

A.1.2
Conditioning of samples; temperature (C) ..........:
N/A
A.1.3
Mounting of samples ............................................:
N/A
A.1.4
Test flame (see IEC 60695-11-3)
N/A
Flame A, B, C or D ...............................................:
Verdict

A.1.5
Test procedure
N/A
A.1.6
Compliance criteria
N/A
Sample 1 burning time (s) .....................................:

Sample 2 burning time (s) .....................................:

Sample 3 burning time (s) .....................................:

N/A
A.2
Flammability test for fire enclosures of movable equipment having a total mass
not exceeding 18 kg, and for material and components located inside fire
enclosures (see 4.7.3.2 and 4.7.3.4)
A.2.1
Samples, material ..................................................:

Wall thickness (mm) ..............................................:

A.2.2
Conditioning of samples; temperature (°C) ..........:
N/A
A.2.3
Mounting of samples ............................................:
N/A
A.2.4
Test flame (see IEC 60695-11-4)
N/A
Flame A, B or C ....................................................:

A.2.5
Test procedure
N/A
A.2.6
Compliance criteria
N/A
Sample 1 burning time (s) .....................................:

Sample 2 burning time (s) .....................................:

Sample 3 burning time (s) .....................................:

TRF No. IEC60950_1F
Page 27 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
A.2.7
Alternative test acc. To IEC 60695-11-5, cl. 5 and
9
N/A
Sample 1 burning time (s) .....................................:

Sample 2 burning time (s) .....................................:

Sample 3 burning time (s) .....................................:

A.3
Hot flaming oil test (see 4.6.2)
N/A
A.3.1
Mounting of samples
N/A
A.3.2
Test procedure
N/A
A.3.3
Compliance criterion
N/A
B
ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS (see 4.7.2.2 and
5.3.2)
N/A
B.1
General requirements
N/A
Position .................................................................:

Manufacturer ........................................................:

Type ......................................................................:

Rated values ........................................................:

N/A
B.2
Test conditions
B.3
Maximum temperatures
(see appended table 5.3)
N/A
B.4
Running overload test
(see appended table 5.3)
N/A
B.5
Locked-rotor overload test
N/A
Test duration (days) ..............................................:

Electric strength test: test voltage (V) ...................:

B.6
Running overload test for d.c. motors in
secondary circuits
N/A
B.6.1
General
N/A
B.6.2
Test procedure
N/A
B.6.3
Alternative test procedure
N/A
B.6.4
Electric strength test; test voltage (V) ...................:
N/A
B.7
Locked-rotor overload test for d.c. motors in
secondary circuits
N/A
B.7.1
General
N/A
B.7.2
Test procedure
N/A
B.7.3
Alternative test procedure
N/A
B.7.4
Electric strength test; test voltage (V) .................. :
N/A
B.8
Test for motors with capacitors
TRF No. IEC60950_1F
(see appended table 5.3)
N/A
Page 28 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
B.9
Test for three-phase motors
(see appended table 5.3)
B.10
Test for series motors
N/A
N/A

Operating voltage (V) ...........................................:
C
Verdict
N/A
ANNEX C, TRANSFORMERS (see 1.5.4 and 5.3.3)
Position .................................................................:

Manufacturer ........................................................:

Type ......................................................................:

Rated values ........................................................:

Method of protection ............................................. :

C.1
Overload test
(see appended table 5.3)
N/A
C.2
Insulation
(see appended tables 5.2 and
C2)
N/A
Protection from displacement of windings ............ :
N/A
D
ANNEX D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS
(see 5.1.4)
N/A
D.1
Measuring instrument
N/A
D.2
Alternative measuring instrument
N/A
E
ANNEX E, TEMPERATURE RISE OF A WINDING (see 1.4.13)
N/A
F
ANNEX F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES
(see 2.10 and Annex G)
N/A
G
ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM
CLEARANCES
N/A
G.1
Clearances
N/A
G.1.1
General
N/A
G.1.2
Summary of the procedure for determining
minimum clearances
N/A
G.2
Determination of mains transient voltage (V)
N/A
G.2.1
AC mains supply ...................................................:
N/A
G.2.2
Earthed d.c. mains supplies .................................:
N/A
G.2.3
Unearthed d.c. mains supplies .............................:
N/A
G.2.4
Battery operation ..................................................:
N/A
TRF No. IEC60950_1F
Page 29 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
G.3
Determination of telecommunication network
transient voltage (V) .......................................... :
N/A
G.4
Determination of required withstand voltage (V)
N/A
G.4.1
Mains transients and internal repetitive peaks .....:
N/A
G.4.2
Transients from telecommunication networks ......:
N/A
G.4.3
Combination of transients
N/A
G.4.4
Transients from cable distribution systems
N/A
G.5
Measurement of transient voltages (V)
N/A
a) Transients from a mains supply
N/A
For an a.c. mains supply
N/A
For a d.c. mains supply
N/A
b) Transients from a telecommunication network
N/A
G.6
Determination of minimum clearances ........... :
N/A
H
ANNEX H, IONIZING RADIATION (see 4.3.13)
N/A
J
ANNEX J, TABLE OF ELECTROCHEMICAL POTENTIALS (see 2.6.5.6)
N/A

Metal(s) used ........................................................:
K
ANNEX K, THERMAL CONTROLS (see 1.5.3 and 5.3.8)
N/A
K.1
Making and breaking capacity
N/A
K.2
Thermostat reliability; operating voltage (V) .........:
N/A
K.3
Thermostat endurance test; operating voltage (V)
...............................................................................:
N/A
K.4
Temperature limiter endurance; operating voltage
(V) .........................................................................:
N/A
K.5
Thermal cut-out reliability
N/A
K.6
Stability of operation
L
ANNEX L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL
BUSINESS EQUIPMENT (see 1.2.2.1 and 4.5.2)
L.1
Typewriters
N/A
L.2
Adding machines and cash registers
N/A
L.3
Erasers
N/A
L.4
Pencil sharpeners
N/A
L.5
Duplicators and copy machines
N/A
L.6
Motor-operated files
N/A
TRF No. IEC60950_1F
(see appended table 5.3)
N/A
P
Page 30 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
L.7
Other business equipment
M
ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1)
N/A
M.1
Introduction
N/A
M.2
Method A
N/A
M.3
Method B
N/A
M.3.1
Ringing signal
N/A
M.3.1.1
Frequency (Hz) .....................................................:

M.3.1.2
Voltage (V) ............................................................:

M.3.1.3
Cadence; time (s), voltage (V) ..............................:

M.3.1.4
Single fault current (Ma) .......................................:

M.3.2
Tripping device and monitoring voltage ................:
N/A
M.3.2.1
Conditions for use of a tripping device or a
monitoring voltage
N/A
M.3.2.2
Tripping device
N/A
M.3.2.3
Monitoring voltage (V) ..........................................:
N/A
N
ANNEX N, IMPULSE TEST GENERATORS (see 1.5.7.2, 1.5.7.3, 2.10.3.9, 6.2.2.1,
7.3.2, 7.4.3 and Clause G.5)
N/A
N.1
ITU-T impulse test generators
N/A
N.2
IEC 60065 impulse test generator
N/A
P
ANNEX P, NORMATIVE REFERENCES
Q
ANNEX Q, Voltage dependent resistors (VDRs) (see 1.5.9.1)
N/A
- Preferred climatic categories ..............................:
N/A
- Maximum continuous voltage .............................:
N/A
- Combination pulse current .................................:
N/A
Body of the VDR
Test according to IEC60695-11-5…......................:
N/A
Body of the VDR.
Flammability class of material ( min V-1)…...........:
N/A
TRF No. IEC60950_1F
Result - Remark
Verdict
P

Page 31 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
R
ANNEX R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL
PROGRAMMES
N/A
R.1
Minimum separation distances for unpopulated
coated printed boards (see 2.10.6.2)
N/A
R.2
Reduced clearances (see 2.10.3)
N/A
S
ANNEX S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3)
N/A
S.1
Test equipment
N/A
S.2
Test procedure
N/A
S.3
Examples of waveforms during impulse testing
N/A
T
ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER
(see 1.1.2)
N/A
See separate test report
U
ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED
INSULATION (see 2.10.5.4)
See separate test report
Verdict

N/A

V
ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1)
N/A
V.1
Introduction
N/A
V.2
TN power distribution systems
N/A
W
ANNEX W, SUMMATION OF TOUCH CURRENTS
N/A
W.1
Touch current from electronic circuits
N/A
W.1.1
Floating circuits
N/A
W.1.2
Earthed circuits
N/A
W.2
Interconnection of several equipments
N/A
W.2.1
Isolation
N/A
W.2.2
Common return, isolated from earth
N/A
W.2.3
Common return, connected to protective earth
N/A
X
ANNEX X, MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS (see clause
C.1)
N/A
X.1
Determination of maximum input current
N/A
X.2
Overload test procedure
N/A
TRF No. IEC60950_1F
Page 32 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
Y
ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see 4.3.13.3)
N/A
Y.1
Test apparatus ..................................................... :
N/A
Y.2
Mounting of test samples ..................................... :
N/A
Y.3
Carbon-arc light-exposure apparatus .................. :
N/A
Y.4
Xenon-arc light exposure apparatus .................... :
N/A
Z
ANNEX Z, OVERVOLTAGE CATEGORIES (see 2.10.3.2 and Clause G.2)
N/A
AA
ANNEX AA, MANDREL TEST (see 2.10.5.8)
N/A
BB
ANNEX BB, CHANGES IN THE SECOND EDITION

CC
ANNEX CC, Evaluation of integrated circuit (IC) current limiters
N/A
CC.1
General
N/A
CC.2
Test program 1……………………………………….:
N/A
CC.3
Test program 2……………………………………….:
N/A
CC.4
Test program 3…..................................................:
N/A
CC.5
Compliance…........................................................:
N/A
DD
ANNEX DD, Requirements for the mounting means of rack-mounted
equipment
N/A
DD.1
General
N/A
DD.2
Mechanical strength test, variable N………………..:
N/A
DD.3
Mechanical strength test, 250N, including end
stops……………………………………………………:
N/A
DD.4
Compliance…………………………………………….:
N/A
EE
ANNEX EE, Household and home/office document/media shredders
N/A
EE.1
General
N/A
EE.2
Markings and instructions
N/A
Use of markings or symbols…………………………:
N/A
Information of user instructions, maintenance and/or
servicing instructions…………………………:
N/A
EE.3
Inadvertent reactivation test…………………………:
N/A
EE.4
Disconnection of power to hazardous moving parts:
N/A
Use of markings or symbols…………………………:
N/A
TRF No. IEC60950_1F
Page 33 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
EE.5
Protection against hazardous moving parts
N/A
Test with test finger (Figure 2A) ……………………:
N/A
Test with wedge probe (Figure EE1 and EE2) ……:
N/A
TRF No. IEC60950_1F
Result - Remark
Verdict
Page 34 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
1.5.1
Requirement + Test
Result - Remark
Verdict
P
TABLE: List of critical components
Object/part No.
Manufacturer/
trademark
Type/model
Technical data
Standard
(Edition / year)
Mark(s) of
conformity1)
PCB
Fai Wong
Electronic
Pcb Co.
FW-4
V-0, 130C,
min. 1.0mm
UL 796
UL 94
UL E171766
Enclosure
LG CHEMICAL
LTD
LUPOY
ER5001RF(#)
V-0, min.
2.0mm, 60°C
UL94
UL746
UL E67171
Supplementary information:
1)
Provided evidence ensures the agreed level of compliance. See OD-CB2039.
1.5.1
N/A
TABLE: Opto Electronic Devices
Manufacturer ............................................... :
Type............................................................. :
Separately tested ........................................ :
Bridging insulation ....................................... :
External creepage distance ......................... :
Internal creepage distance .......................... :
Distance through insulation ......................... :
Tested under the following conditions ......... :
Input............................................................. :
Output .......................................................... :
supplementary information
1.6.2
TABLE: Electrical data (in normal conditions)
P
U (V)
I (A)
Irated (A)
P (W)
Fuse #
Ifuse (A)
Condition/status
12V
1.42
1.5
17.0
--
--
Max normal load
Supplementary information:
N/A
TRF No. IEC60950_1F
Page 35 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
2.1.1.5 c)
1)
TABLE: max. V, A, VA test
Voltage (rated)
(V)
Result - Remark
Current (rated)
(A)
Verdict
N/A
Voltage (max.)
(V)
Current (max.)
(A)
VA (max.)
(VA)
supplementary information:
2.1.1.5 c)
2)
N/A
TABLE: stored energy
Capacitance C (µF)
Voltage U (V)
Energy E (J)
supplementary information:
2.2
TABLE: evaluation of voltage limiting components in SELV circuits
Component (measured between)
max. voltage (V)
(normal operation)
V peak
Voltage Limiting Components
V d.c.
T1 Between output wiring
Fault test performed on voltage limiting components
-supplementary information:
TRF No. IEC60950_1F
N/A
Voltage measured (V) in SELV circuits
(V peak or V d.c.)
Page 36 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
2.5
TABLE: Limited power sources
Verdict
N/A
Circuit output tested:
Note: Measured Uoc (V) with all load circuits disconnected:
Components
Test condition
(Single fault)
Uoc (V)
Isc (A)
VA
Meas.
Limit
Meas.
Limit
supplementary information:
Sc=Short circuit, Oc=Open circuit
2.10.2
N/A
Table: working voltage measurement
Location
RMS voltage (V)
Peak voltage (V) Comments
supplementary information:
N/A
2.10.3 and TABLE: Clearance and creepage distance measurements
2.10.4
Clearance (cl) and creepage
distance (cr) at/of/between:
2.10.5
U peak
(V)
U r.m.s.
(V)
Required cl
(mm)
cl
(mm)
Required cr
(mm)
N/A
TABLE: Distance through insulation measurements
Distance through insulation (DTI) at/of:
Supplementary information:--
TRF No. IEC60950_1F
U peak
(V)
U rms
(V)
Test voltage(V)
cr
(mm)
Required DTI
(mm)
DTI
(mm)
Page 37 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
4.3.8
TABLE: Batteries
Result - Remark
Verdict
N/A
The tests of 4.3.8 are applicable only when appropriate battery
data is not available
--
--
Is it possible to install the battery in a reverse polarity position?
Non-rechargeable batteries
Discharging
Meas.
current
Manuf.
Specs.
Unintentional
charging
N/A
Rechargeable batteries
Charging
Meas.
current
Manuf.
Specs.
Discharging
Meas.
current
Manuf.
Specs.
Reversed
charging
Meas.
current
Manuf.
Specs.
Max.
current
during
normal
condition
Max.
current
during
fault
condition
Test results:
Verdict
- Chemical leaks
- Explosion of the battery
- Emission of flame or expulsion of molten metal
- Electric strength tests of equipment after completion of tests
Supplementary information:
4.3.8
N/A
TABLE: Batteries
Battery category .......................................... :
(Lithium, NiMh, NiCad, Lithium Ion …)
Manufacturer ............................................... :
Type / model ................................................ :
Voltage ........................................................ :
Capacity....................................................... :
Tested and Certified by (incl. Ref. No.) ....... :
Circuit protection diagram:
TRF No. IEC60950_1F
mAh
Page 38 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
MARKINGS AND INSTRUCTIONS (1.7.13 )
Location of replaceable battery
Language(s) …………………………………….:
Close to the battery …………………………….:
In the servicing instructions ……………………:
In the operating instructions …………………..:
4.5
--
P
--
TABLE: Thermal requirements
Supply voltage (V) ........................... :
12VDC
Ambient Tmin (C) ............................. :
25.5
25.0
--

Ambient Tmax (C) ............................ :
25.5
25.0
--

Maximum measured temperature T of part/at......:
T (C)
PCB
26.3
26.1
Connecting wire
25.6
25.2
Handle(inside)
25.6
25.1
--
70
Handle(outside)
25.7
25.6
--
70
Enclosure
25.5
25.1
--
70
Allowe
d Tmax
(C)
--
130
105
Supplementary information:
Temperature T of winding:
t1 (°C)
R1 ()
t2 (°C)
R2 ()
T (C)
Allowed
Tmax (C)
Insulatio
n class
Supplementary information:
4.5.5
N/A
TABLE: Ball pressure test of thermoplastic parts
Allowed impression diameter (mm) ..................... :
Part
Supplementary information:--
TRF No. IEC60950_1F
 2 mm

Test temperature Impression diameter
(mm)
(C)
Page 39 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
4.7
TABLE: Resistance to fire
Part
Result - Remark
Verdict
P
Type of material
Evidence
Thickness Flammability
(mm)
class
PCB
FW-4
1.0
V-0
UL E171766
Enclosure
LUPOY ER5001RF(#)
2.0mm
V-0
UL E67171
Supplementary information:
5.1
N/A
TABLE: touch current measurement
Measured between:
Measured
(mA)
Limit
(mA)
Comments/conditions
supplementary information:
5.2
TABLE: Electric strength tests, impulse tests and voltage surge tests
Test voltage applied between:
Voltage shape
(AC, DC,
impulse, surge)
Test
voltage (V)
N/A
Breakdown
Yes / No
Supplementary information:
5.3
P
TABLE: Fault condition tests
Ambient temperature (C) ................................... :
25C if not mentioned

Power source for EUT: Manufacturer, model/type,
output rating ......................................................... :
See page 1

Component
No.
Fault
Supply
voltage
(V)
Test
time
Fuse
#
Fuse
current
(A)
D15
S-C
12VDC
10mins
--
--
TRF No. IEC60950_1F
Observation
The appliance works normally
Page 40 of 42
Report No. : UNI2015122413SR-01
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
D4
S-C
12VDC
10mins
--
--
The appliance works normally
D16
S-C
12VDC
10mins
--
--
Power reduced, recoverable
C10
S-C
12VDC
10mins
--
--
The appliance works normally
Supplementary information: S-C=short cicuit
C.2
Loc.
Loc.
N/A
TABLE: transformers
Tested insulation
Working
voltage
peak / V
Working
voltage
rms / V
Required
electric
strength
Required
clearance /
mm
(2.10.2)
(2.10.2)
(5.2)
Test
voltage/
V
Tested insulation
Required
distance thr.
insul.
(2.10.3)
Required
creepage
distance /
mm
(2.10.4)
Measured
clearance /
mm
Measured
creepage
dist./ mm
Measured
distance thr.
insul. / mm;
number of
layers
(2.10.5)
supplementary information:
* 2 or 3 layers / 0.4mm / Annex U
C.2
TABLE: transformers
Transformer
TRF No. IEC60950_1F
N/A
Page 41 of 42
Attachment: Photos of the product:
Photo 1: Overall view
Photo 2: Bottom view
TRF No. IEC60950_1F
Report No. : UNI2015122413SR-01
Page 42 of 42
Report No. : UNI2015122413SR-01
Photo 3: Internal view
Photo 4: Internal view
-------------------End of report-------------------