Omega LV600 Series Owner Manual

Omega LV600 Series Owner Manual
LV600 SERIES LEVEL SWITCHES
©
FIG.3
FIGA
The wire that is no: used must be correctly insulated
EMPTYING
FILLING
The regulators are hemologated in compliance with CEI EN 60750 standards and thereby comply
with the fundamental requisites of Directive 93/68/EEC .
The appliance combined with a pump connected by a flexible cable, permits the regulation of the
level of the liquid in which itis immersed.
INSTALLATION
To ensure the efficient function of the appliance itis necessary to fix the electric cable inside the
tank or well as illustrated in figures no.5 and no.6.
The length of the cable section between the fixture point of the same and the regulator body,
determines the total extension of the float and the consequent distances between the pump
stopping and starting level itis also necessary to check that the float is not obstructed during its
run.
During installation joins to the level regulator cable must not be made under any circumstances.
An eventual cable join section must never be immersed in water,
if the float is used in filling mode, the system must be fitted with an adequate overflow device.
COUNTERWEIGHT INSTALLATION IF PRESENT IN THE RETAIL PACKAGING
For correct counterweight installation refer to the following procedure as illustrated in figure no.7.
1.Insert the cable into the counterweight, from the conic part, tuming it. This will result in the
detachmen: of the plastic ring inserted in the mouth (if necessary aid detachment by using a
screwdriver).Place the ring at the point of the cable where the counterweight is to be fixed.
2 Fix the counterweight on the ring using moderate pressure and turning it.
The counterweight is only provided on request.
ELECTRICAL CONNECTIONS
The regulator may be used for filling or emptying according to thi connections made between the
terminals of the microswitch and the cable.
For correct product installation refer to wiring diagrams in figures no.1-2-3-4.
Always disconnect the power supply from the main power panel before undertaking any
operations on the float.
NOTE
When making the connections described above ensure that the maximim motor power does not
exceed the values indicated on the level regulator.
The power supply cable is an integral part of the appliance. Should the cable be found to be
damaged the appliance is to be replaced.Repairs to the cable itself are not possible.
The earth wire of yellow/green colour must be connected to a suitable earth terminal and the
cn section dimension must nat be less than 1 mm”. The eventual terminal used must be effectively
FIG.6 protected against accidental slackening.
ELECTRICAL FEATURES
MAXIMUM OPERATIONAL TEMPERATURE 50°C
PROTECTION GRADE IP68 (tested by IMQ at a depth of 1m for a period
of 7 days at watertemp.of 50 °C)
MAC3 RELIABILITY TEST The appliar ces pass an immersion test at depth
of 10 m,at a temperature of 50 °C for a period
INSTALLATION OF of 7days. и |
LA _ tie rn FEATURES OF AUTOMATICACTION 1B (micro-disconnections in operation}
COUNTERWEIGH | P
FIG.7
CAUTION! CAUTION! CAUTION!
Level switches are manufactured to the highest quality specifications. However, due to their economical
construction, they should be used only for applications where, in the event of product failure, the risk of
damage to equipment or personnel would be minimized. In the case of level switches, one or two back-up
switches should also be used to ensure that failure of any one switch will be mitigated by the back-up level
switch(s). The user should periodically inspect the product’s performance in the actual application. Usc of
the products beyond the recommended capabilities and lifespan is specifically not recommended.
CAUTION! CAUTION! CAUTION!
Before installation check your local electrical codes. To avoid personal injury when servicing your
equipment be sure that power is disconnected from both the equipment and the float switch.
Warning: To reduce the risk of electrical shock connect only to a properly grounded, grounding type