Scarica il datasheet : HP_16700_Product_Overview

Scarica il datasheet : HP_16700_Product_Overview
HP 16600A and 16700A Series
Logic Analysis System Mainframes
Product Overview
Solutions for
Digital System Debug
The Advantage of Insight
Debugging today’s digital systems is
tougher than ever. Increased product requirements, complex software,
and innovative hardware technologies make it difficult to meet your
time-to-market goals.
As a digital designer, you need test
equipment that quickly provides
reliable insight into your toughest
problems. That is why HP has combined logic analysis, emulation and
software tools into one integrated
system — to give you a complete
view of your prototype, from
signals to source code.
HP has a solution to help you
completely outfit your team while
providing budgetary flexibility. With
HP’s scalable systems, you won’t
waste money on features you'll
never use. And you won’t be faced
with scrapping recently bought tools
just because you changed microprocessors.
Figure 1. (left to right) The HP 16700A, 16702A and 16600A logic analysis systems.
2
Key Features Overview
Figure 2.
Acquire state data
at 333 MHz and
timing data at up to
2 GHz through the
same connection.
Figure 3.
Configure your
HP 16700A Series
system for your specific application with
modular mainframes.
Features
Benefits
___________________________________________________________________________________________________________________________
Scalable System
• Room to grow
• State/timing analyzers
• Select the optimum combination of performance, features, and price that you need
• Oscilloscopes
for your specific application today, with the flexibility to add to your system as your
• High-speed timing
measurement needs change.
• Pattern generator
• View system activity from signals to source code.
• Emulation module
___________________________________________________________________________________________________________________________
Timing Zoom Technology
• Simultaneously acquire data at up to 2 GHz timing and 333 MHz state through the same connection.
Timing Zoom is available across all channels, all the time. (See pg 9)
___________________________________________________________________________________________________________________________
VisiTrigger Technology
• Use graphical views and sentence-like structure to help you define a trace event .
• Select trigger functions as individual trigger conditions or as building blocks to easily customize a
trigger for your specific task.
___________________________________________________________________________________________________________________________
Processor and Bus Support
• Get control over your microprocessor’s internal and external data.
• Quickly and reliably connect to the device under test. (See pg 10-11)
___________________________________________________________________________________________________________________________
Post-Processing Analysis Tools
• Rapidly consolidate large amounts of data into displays that provide insight into your
system’s behavior. (See pg 10)
___________________________________________________________________________________________________________________________
Setup Assistant
• Quickly configure the logic analysis system for your target microprocessor. (See pg 5).
___________________________________________________________________________________________________________________________
Tabbed Interface
• Groups like tasks together so you can quickly find and complete the task you want to perform.
• Spend your time solving problems, not setting up a measurement.
___________________________________________________________________________________________________________________________
Multi-Windowed View of
• View your cross-domain measurements, time-correlated on the same screen. (See pg 5)
Target System Activity
• Debug faster because you can view system activity at a glance.
___________________________________________________________________________________________________________________________
Global Markers
• Track a symptom in one domain (timing) to its cause in another domain (analog).
___________________________________________________________________________________________________________________________
3
Key Features Overview
(cont.)
Features
Benefits
___________________________________________________________________________________________________________________________
Resizable Windows and Data Views
• Magnify your view or zoom in on a boxed area of interest.
• Resize waveforms and data or quickly change colors to highlight areas of interest.
_____________________________________________________________________________________________________________________________
Web-Enabled System
• Directly access the instrument’s web page from your web browser. (See pgs. 6 & 7)
• Remotely check the instrument’s measurement status without disturbing the acquisition.
• Remotely access, monitor and control your logic analysis system.
___________________________________________________________________________________________________________________________
Direct Link to Microsoft® Excel via
• Automatically move your data from the logic analyzer into Microsoft Excel with just a
HP BenchLink XL 16700
click of the mouse. (See pg 7)
• Use Microsoft Excel’s powerful functions to post-process captured trace data to get the insight
you need.
___________________________________________________________________________________________________________________________
Direct Links to Industry
• Debuggers provide visibility into software execution for systems running software written
Standard Debuggers and
in C and C++ as well as active microprocessor execution control (run control). (See pg. 11)
High-Level Language Tools
• Import symbol files created by your language tools. Symbols allow you to set up trigger
conditions and review waveform and state listings in easily recognized terms that relate
directly to the names used for signals on your target and the functions and variables in
your code.
___________________________________________________________________________________________________________________________
Direct Links to EDA Tools
• Use captured logic analysis waveforms to generate simulation test vectors.
• Easily find problems by comparing captured waveforms with simulated waveforms.
___________________________________________________________________________________________________________________________
Transfer Data for Offline
• Fast binary (compressed binary) from the FileOut tool provides highest performance transfer rate.
Analysis – Data Export
• ASCII format provides same format as listing display, including inverse-assembled data.
___________________________________________________________________________________________________________________________
Transparent File System Access
• Access, transfer, and archive files.
• Stay synchronized with your source code by mapping shared directories and file systems
from your Windows 95/98/NT-based PC directly onto the logic analyzer and vice versa.
• Move data files to and from the logic analyzer for archive or use elsewhere.
___________________________________________________________________________________________________________________________
Documentation Capability
• Save graphics in standard TIFF, PCX, and EPS formats.
• Print screen shots and trace listings to a local or networked printer.
• Save your lab notes and trace data in the same file by entering relevant information in the
Comments tab of the display.
___________________________________________________________________________________________________________________________
Remote Programming with
• Perform pass/fail analysis, stimulus response tests, data acquisition for offline analysis, and
Microsoft’s COM Using
system verification and characterization tests.
Microsoft Visual Basic or
• Powerful-yet-efficient command set focuses on your programming tasks, resulting in a shorter
Visual C++
learning curve while maintaining necessary functionality.
(See pg. 14 for more information)
___________________________________________________________________________________________________________________________
Network Security
• Protect your networked assets and comply with your company’s security requirements with
individual user logins that provide system integrity.
___________________________________________________________________________________________________________________________
4
Key Features
Modularity is the key to the HP 16600A and 16700A Series logic analysis
systems’ long term value. You purchase only the capability you need now,
then expand as your needs evolve. All modules are tightly integrated to
provide time-correlated, cross-domain measurements.
Emulation
The emulation module connects to the debug
port (BDM or JTAG) on your target. You have full
access to processor execution control features
of the module through the built-in emulation
control interface or a third-party debugger.
Module Choices
State/Timing
HP offers a wide variety of state/timing modules
to help you match your debug tools to your
specific measurement needs. These modules
include high-speed acquisition to capture
glitches, wide channel counts to monitor all of
the signals from a high-end processor system,
and deep memory to capture elusive system
crashes. See page 9.
Oscilloscope
Identify signal integrity issues and characterize
signals quickly with automatic measurements of
rise time, voltage, pulse width, and frequency.
High-Speed Timing
Precisely characterize setup/hold times over a
wide channel count. Capture data over many
clock cycles while retaining the highest multichannel accuracy.
Pattern Generation
Use stimulus to substitute for missing system
components or provide a stimulus-response test
environment.
Use the target control
port to activate your
target’s reset or interrupt lines, making it
convenient to control
the target remotely.
Port-in/Port-out BNC
connectors allow you
to trigger or arm external devices or receive
signals that can be
used to arm acquisition
modules within the
logic analysis system.
Figure 4. The
power-up screen
lets you identify
and access the
measurement capability available in
your logic analysis
system.
Table 1. HP 16600A and 16700A Series Supported Measurement Modules
________________________________________________________________________________________________________________________
Measurement
HP Model Number
Description
Module Category
________________________________________________________________________________________________________________________
16717A 1
333 MHz state, 667 MHz timing, 2 GHz Timing Zoom, 2/4 M memory depth
_____________________________________________________________________________________________
16716A 1
167 MHz state, 667 MHz timing, 2 GHz Timing Zoom, 512K/1M memory depth
_____________________________________________________________________________________________
16715A 1
167 MHz state, 667 MHz timing, 2/4 M memory depth
_____________________________________________________________________________________________
16710A/16711A/16712A
100 MHz state, 500 MHz timing, 8K/32K/128K deep memory depth
_____________________________________________________________________________________________
16557D
140 MHz state, 500 MHz timing, 2/4 M memory depth
_____________________________________________________________________________________________
16556A/D
100 MHz state, 400 MHz timing, 2/4 M memory depth
_____________________________________________________________________________________________
16555A/D
110 MHz state, 500 MHz timing, 2/4 M memory depth
_____________________________________________________________________________________________
16554A
100 MHz state, 250 MHz timing, 512 K/1M memory depth
_____________________________________________________________________________________________
16550A
100 MHz state, 500 MHz timing, 4/8K memory depth
________________________________________________________________________________________________________________________
Oscilloscopes
16534A
2 channel, 500 MHz bandwidth
_____________________________________________________________________________________________
16533A
2 channel, 250 MHz bandwidth
________________________________________________________________________________________________________________________
HIgh-Speed Timing
16517A/16518A
4 GHz timing, 1 GHz synchronous state, 64K memory depth (master/expander)
________________________________________________________________________________________________________________________
Pattern Generator
16522A
200 M vector/second pattern generator
________________________________________________________________________________________________________________________
Emulation
E5901A
Processor-specific device provides code download, register/memory modification,
and processor control (including break, run, reset, single step)
________________________________________________________________________________________________________________________
1 Currently only supported in the HP 16700A Series.
State and Timing
5
Key Features (Cont.)
System Setup Is As Easy
As a Mouse Click
Figure 5. Setup
Assistant gets
you up and running quickly.
Figure 6. Icons in
the power-up
screen give you
quick access to
common tasks
Setup Assistant is a
guided menu system
that helps you configure the logic analysis
system for your target
microprocessor or
bus. Online information guides you
through the setup.
(See Figure 5)
System Admin allows
you to set up the
instrument on your
network, establish
printers, set up user
accounts for security,
or update software
quickly.
Demo Center provides
simple demos of the
most commonly-used
features.
Help enables you to
access the online User’s
Guide and measurement
examples. The Help system
includes full search and
hypertext link capabilities.
See the Big Picture of
Your Prototype System’s
Behavior
The large display with multiple,
resizable windows on the HP 16600A
and 16700A allows you to see at a
glance more of your target system’s
operation. A built-in, flat-panel
display in the HP 16702A fits in environments with limited space. Color
lets you highlight critical information
so you can find it quickly.
Use one tool to examine target operation from different perspectives.
Multiple time-correlated views of
data let you confirm both signal
integrity and software execution
flow. This is invaluable in solving
cross-domain problems.
Figure 7. You can quickly isolate the root cause of system problems by examining target operation across a wide analysis domain, from signals to source code.
6
Key Features (cont.)
Expanding Possibilities
with Network Connectivity
View and analyze the data anywhere, anyplace, anytime
Web-enabled instrumentation gives
you the freedom to access the system—anywhere, anytime. Have you
ever needed to check on a measurement's status while you were in a
remote location? Now you can!
With a Web Enabled Logic
Analysis System You Can...
...access the logic analysis system’s web page
from your browser by typing in the logic analysis system’s URL (hostname or IP address).
...access HP's web site for the latest online
manuals and technical information.
...quickly check instrument status to determine
if the analyzer is available for use.
...remotely check current measurement status
to find out if the system has triggered.
...access the analyzer's user interface directly
from within your browser, giving you full control of all analyzer functions.
...install HP Benchlink XL 16700 to seamlessly
transfer data from the analyzer to the PC.
Figure 8.
Your logic analyzer
is its own web site.
From the Home
Page you can perform multiple
remote functions.
When your logic analysis system is
connected to your company’s
Intranet, you can directly access its
web page from your web browser,
whether you're in the office, at
home, or at another site. Working
from multiple locations has never
been this convenient.
Key Features (cont.)
Remote Control Helps to
Improve the Efficiency of Your
Debug Efforts.
Check up on long duration measurements to
determine if you need to change a trigger
specification or save captured data to a file.
Simultaneously share your measurement
results with other team members in different
locations. Work concurrently to make realtime decisions and solve problems.
Remotely access the target control port to
reset the target, then set up a different measurement and start another acquisition.
Figure 9.
From your web
browser, you
have full remote
control of all
logic analyzer
functions.
HP BenchLink XL 16700 Moves
Your Data Automatically into
Microsoft Excel for Advanced
Offline Analysis
Use the HP BenchLink XL 16700 tool bar to
connect to an HP logic analysis system. Select
from the available labels and specify the
destination cell location in Excel.
Import data from the current acquisition or data
previously saved to a file via the File Out tool.
Use Microsoft Excel's powerful functions to
post-process captured trace data for the insight
you need.
Figure 10.
Transfer data
into Excel with
just a click of the
mouse.
7
8
Selecting a System that’s
Right for You
The following pages describe the
components available to configure
a system that meets your digital
debug needs. For a list of all supported measurement modules for
the HP 16600A and 16700A Series
mainframes, refer to page 4.
Your mainframe and measurement
module selection depends on:
•Desired mainframe form factor
•Availability of extra slots for future
measurement capabilities
•Number of state/timing analysis
channels needed
•Additional measurement/analysis
capabilities: oscilloscope, pattern
generator, high-speed timing, emulation, microprocessor and bus
support, and post-processing
analysis software
•Accessories
•Service and support
•Budget
Available Mainframes
The HP 16700A Series platform is a
modular system that can change as
your needs grow. You decide which
state and timing analysis module(s)
you want, then you add other measurement modules to meet your
debug needs.
The HP 16600A Series logic analysis
system offers built-in state and
timing capabilities from 68 to 204
channels. These channel configurations are fixed. However, each frame
contains one expansion slot for additional measurement capability, such
as an oscilloscope, pattern generator,
or analysis module.
Table 2. Top-Level Comparison of the HP 16700A and
16600A Series Mainframes
16700A
16702A
16600A/16601A/16602A/16603A
________________________________________
Mainframe–HP Model
Slots for measurement modules
5 (10 total with HP 16701A
1
expansion frame)
_______________________________________________________________________________
Built
in state/timing channels
None
None
204, 136, 102, 68
_______________________________________________________________________________
Number of emulation
2 (4 total with HP 16701A
1
module
slots
expansion frame)
_______________________________________________________________________________
HP 16701A expansion
Yes
Yes
No
frame
support
_______________________________________________________________________________
Built-in
display
No
800 × 600, 10.3”
No
_______________________________________________________________________________
External monitor supported
1280 × 1024 std.,1600 × 1200 opt. 003, or remote via web browser
or X-windows
_______________________________________________________________________________
Table 3. Built-in Logic Analysis Capability of the
HP 16600A Series Analyzers
16600A
16601A
16602A
16603A
_______________________________________
HP Models
Maximum
state clock
100 MHz
100 MHz
100 MHz
100 MHz
_______________________________________________________________________________
Maximum timing sampling
125/250 MHz
125/250 MHz
125/250 MHz
125/250 MHz
rate
(full/half channels)
_______________________________________________________________________________
Memory depth (full/half
64/128 K1
64/128 K1
64/128 K1
64/128 K1
channels)
_______________________________________________________________________________
Channels supported
204
136
102
68
_______________________________________________________________________________
Supports context store
Yes
Yes
Yes
Yes
_______________________________________________________________________________
Setup/hold time
0/4.5 ns to 4.5/0 ns adjustable in 500 ps increments
_______________________________________________________________________________
1 Increased memory depth in half channel timing mode only.
With Context Store,
Capture Infrequent
Problems Every Time
They Occur
The HP 16600A Series mainframes
and the HP 16710A, 16711A, and
16712A measurement modules
support advanced state and timing
acquisition technology, including
context store.
Using context store, you can store
the events that occur before and
after a specific trigger condition in
a time window centered approximately around an event. Trace
memory is filled only with data that
is specific to the measurement you
want to make.
Hardware engineers can use context store when searching for the
cause of events that occur infrequently or randomly in time, but
that seem to be correlated to specific conditions, such as interrupts or
writes to certain address ranges.
When you are debugging software
or trying to determine if the cause
of a problem is in the hardware or
software, context store makes it
easy to identify the cause of memory and pointer corruption problems
without having to sort through large
amounts of trace data.
9
Selecting a System that’s
Right for You (cont.)
Available State and
Timing Analysis
Measurement Modules
HP offers logic analysis modules
that vary in channel count,
acquisition speed, and memory
depth so that you can select the
capability that meets your needs as
well as your budget.
The Speed and Triggering
You Need for Tomorrow,
Available Today
HP Timing Zoom Technology
(HP 16716A and 16717A)
Enables You To:
•Simultaneously acquire up to
2 GHz timing and 333 MHz state
data across all channels, all the
time, through the same connection
•Vary the Timing Zoom sample rate
from 250 MHz to 2 GHz
•Capture 16K memory depth
•Vary the placement of Timing
Zoom data around the trigger
point
•Efficiently characterize hardware
with 500 ps resolution
HP VisiTrigger Technology
(HP 16715A, 16716A and
16717A) Lets You:
•Use graphical views and sentencelike structure to help you define a
trace event.
•Select trigger functions as individual trigger conditions or as building blocks to easily customize a
trigger for your specific task.
•Set global counters to count
events such as the number of
times a function executes, or the
number of accesses to an I/O port.
•Set, clear or evaluate flags by any
module in the frame. Flags allow
you to set up a trigger that is
dependent on activity from more
than one bus in the system.
•Specify four-way arbitrary
IF/THEN/ELSE branching.
Table 4. New State and Timing Modules
16715A
16716A
16717A
________________________________________
NEW HP Models
Maximum
state clock
167 MHz
167 MHz
333 MHz
_______________________________________________________________________________
Maximum timing
333/667 MHz
333/667 MHz
333/667 MHz
sample rate
2 GHz Timing Zoom 2 GHz Timing Zoom
(full/half
channels)
_______________________________________________________________________________
Memory depth
2/4 M1
512 K/1 M1
2/4 M1
full/half
channels)
_______________________________________________________________________________
Channels/module
68
68
68
_______________________________________________________________________________
Maximum channels on
340
340
340
a_______________________________________________________________________________
single time base
Maximum channels in
680
680
680
an HP 16700 Series
system
with an HP 16701A
_______________________________________________________________________________
Setup/hold time
4.5/–2.0 ns to
4.5/–2.0 ns to
4.5/–2.0 ns to
–2.0/4.5 ns in
–2.0/4.5 ns in
–2.0/4.5 ns in
100 ps increments 2 100 ps increments 2 100 ps increments 2
_______________________________________________________________________________
Table 5. State and Timing Modules for the HP 16600A
and 16700A Series Mainframes
HP Model
16550A
16557D
1-4 Modules 5 Modules
16517A,
16518A
16710A,
16711A,
16712A
________________________________________
Maximum
state clock
100 MHz
140 MHz
100 MHz
1 GHz
100 MHz
________________________________________________________________________________
Maximum timing
500 MHz
500 MHz
4 GHz
500 MHz
sampling rate
________________________________________________________________________________
Memory depth
4/8 K
2/4 M1
64/128 K1
8/16K1,
(full/half channels)
32/64K1,
1
128/256K
________________________________________________________________________________
Channels/module
102
68
16
102
________________________________________________________________________________
Maximum channels
204
272
304
80
204
(on a single time
base and trigger)
________________________________________________________________________________
Maximum channels
1020
680
160
1020
in an HP 16700 series
system (w/ HP 16701A
expansion
mainframe)
________________________________________________________________________________
Setup/hold time
3.5/0 ns to
3.0/0 ns to –0.5/3.5 ns
350 ps/ 350 ps 4.5/0 ns to 0/4.5 ns
0/3.5 ns,
adjustable in
adjustable in 500 ps
adjustable in 500 ps increments
increments 3
500 ps
increments
________________________________________________________________________________
1 Increased memory depth in half channel timing mode only.
2 Minimum setup/hold time specified for single edge, single clock acquisition. Multi-clock, multi-edge add 0.5 ns.
3 Minimum setup/hold time specified for single edge, single clock acquisition. Single clock,
multi-edge setup/hold window is 5.0 ns. Multi-clock, multi-edge setup hold window is 5.5 ns.
Selecting a System that’s
Right for You (cont.)
10
Post-Processing Tool Sets Table 6. Optional Software Tool Sets for the
Provide Rapid Insight Into HP 16600A and 16700A Series Mainframes.
Your Toughest Debug
Application
Product Name
Problems
HP Model
Number
_______________________________________________________________________________
When you want to really understand what your target is doing and
why, you need to be able to view
acquisition results in a format that
quickly guides you to problem
identification.
Each tool set described in Table 6
is an optional post-processing software package for the HP 16600A
and 16700A Series logic analysis
systems. The tool sets offer you a
variety of views of the same realtime data to give you insight into
your specific application.
Speed Problem Solving
with Off-the-Shelf
Solutions for Many
Common Microprocessors
Debug your real-time code at the source level.
Source Correlation
B4620B
Correlate the logic analyzer trace with the
Tool Set
high-level source code that produced it. Set up
the logic analyzer trace by simply pointing and
clicking
on a line of source code.
_______________________________________________________________________________
Customize your trace for greater insight.
Tool Development Kit
B4605B
Create custom tools using the C programming
language. Custom tools can analyze captured
data and present it in a form that makes sense
to you. Analysis systems do not require the Tool
Development Kit to run generated tools.
_______________________________________________________________________________
Optimize your system’s performance.
System Performance
B4600B
Profile your system’s performance to identify
Analysis Tool Set
system bottlenecks and to identify areas
needing
optimization.
_______________________________________________________________________________
Solve your serial communication problems.
Serial Analysis
B4601B
Convert serial bit streams to parallel format for
Tool Set
easy viewing and analysis. Supports serial data
with or without an external clock reference and
protocols that use bit stuffing to maintain clock
synchronization. Works at speeds up to 1 GHz.
_______________________________________________________________________________
To help you design and debug your
microprocessor-based target
systems, HP offers different microprocessor specific products that let
you get control and visibility over
your microprocessor’s internal and
external data.
An analysis probe allows you to
quickly connect an HP logic analyzer
to your target system. The analysis
probe provides non-intrusive capture
and disassembly of microprocessor
and bus activity.
Analysis probes are available for
over 200 microprocessors and
microcontrollers. Bus probes allow
probing of popular bus architectures such as PCI, AGP, USB, VXI,
SCSI, and many others.
Flexible physical probing schemes
give quick and reliable connections
to almost any device on your
prototype.
Figure 11. HP analysis probes (formerly known as preprocessors) make it easy to
connect a logic analyzer to your target system.
11
Selecting a System that’s
Right for You (cont.)
On-Chip Emulation Tools
Make Fixing Bugs Easier
For specific microprocessor
families that feature on-chip emulation, you can add an emulation
module to your system to connect
the on-board debugging resources
of the microprocessor to the logic
analysis system.
The microprocessor’s BDM or JTAG
technology provides control over
processor operation even if there is
no software monitor on the target
system. This feature is particularly
helpful during the development of
your target system’s boot code.
Integrated Debugger Support
When the hardware turn-on phase
is completed, the same HP emulation module can be connected to
high-level debuggers for C or C++
software development.
You can achieve the functionality
of a full-featured emulator by using
a third-party debugger to drive the
installed HP emulation module.
This gives you active and complete
microprocessor execution control
(run control).
Emulation Control Interface
The emulation control interface is
accessed from the power up screen
of the HP 16600A or 16700A Series
system. The interface is included
standard for those microprocessors
supported with the HP E5901A
emulation module.
Designed for hardware engineers,
this generic graphical user interface
provides the following features:
• Control over processor execution:
run/break/reset/step
• Register display/modification
• Memory display/modification in
various formats including disassembly for code visualization. Memory
modification or memory bloc fill
can be done to check processor
memory access or to reinitialize
memory areas.
• Multiple breakpoint configuration:
hardware, software, and processor
internal breakpoint registers.
• Code download to the target
• Command scripts to reproduce test
sequences.
• The ability to trigger a measurement module on a processor break
or receive a trigger from the logic
analysis system’s measurement
modules.
Figure 12. Emulation Control Interface
12
Accessories and Support
HP 1184A Testmobile
HP Support and Services
The HP 1184A testmobile gives you
a convenient means of organizing
your HP logic analysis system
mainframes and accessories.
HP’s family of support services complements your logic analysis system
to provide a complete solution. HP’s
expertise allows you to
concentrate on your particular
design projects and applications,
rather than your debug tools, resulting in increased productivity.
The testmobile includes the
following:
• Drawer for accessories (probes,
cables, power cords)
• Keyboard tray with adjustable tilt
and height
• Mouse extension on keyboard tray
accommodates either right or left
hand operation
• Locking casters for safety on
uneven surfaces
• Strap provided to stabilize the
monitor
• Load limits:
Top tray: 68.2 kg (150.0 lb.)
Lower tray: 68.2 kg (150.0 lb.)
Total: 136.4 kg (300.0 lb.)
Figure 13. HP 1184A testmobile cart
Weight
Max Net
Max. Shipping
_____________________________________
HP 1184A 48.0 kg (106.0 lb) 59.0 kg (130.0 lb)
_____________________________________
584.2
(23.0)
469.9
(18.5)
652.8
(25.7)
243.8
(9.6)
190.5
(7.5)
772.2 482.6
(30.4) (19.0)
774.7
(30.5)
254
(10.0)
594.4
(23.4)
Figure 14. HP 1184A testmobile cart dimensions. Dimensions: mm (inches).
HP can provide consulting to assist
in making specific measurements,
applying debug techniques, and
understanding the issues related to
specific processors. On-site assistance can be provided for initial turnon of your target system. Contact
your local HP representative for
more information on HP consulting
services available in your area.
HP training courses include
extensive hands-on and are designed
to pay off immediately in real-world
situations. HP training can be
delivered through scheduled classes,
on-site classes, or one-on-one consulting. For training offered in your
geography and language, consult the
HP test and measurement education
web site:
http://www.hp.com/go/tmeducation
HP on-line support professionals
can help you better use digital
system debug tools to maximize
your investment and minimize your
debug time. Operational verification
and standard measurement
assistance can be provided via vari866.1 ous methods including phone, fax,
(34.1) e-mail, or web.
116.8
(4.6)
The standard warranty for your
system may be enhanced via a
return-to-HP warranty extension, a
conversion to on-site warranty,
installation services, and calibration
services.
HP 16600A and 16700A Series
Technical Information
System Software
All features and functionality described in this
document are available with system software
version A.01.40.00
____________________
Mass Storage
Hard
Disk Drive 4 GB formatted disk drive
______________________________________
Floppy Disk Drive
HP
BenchLink XL 16700 Support
______________________________________
Operating Environment
Installation of
Directly from instrument web
PC Application page
Software
______________________________________
Temperature
Microsoft
Excel 97
Version 7.0 or higher
Excel limits maximum trace
depth to 64K per sheet.
______________________________________
____________________
Available Data Formats
Formats
High performance transfer
rate. Includes source code
to parse data. Available via
File Out.
______________________________________
____________________
ASCII
Capacity
1.44 MB formatted
Media
3.5 inch floppy
MS-D0S (Read, write, format), LIF (Read only)
______________________________________
Internal System RAM
Standard
64 MB
______________________________________
Option 003 (Must 160 MB total
be ordered at
time of frame
purchase)
______________________________________
13
Fast Binary
(Compressed
Binary Format)
Uncompressed
Includes utility routines.
Binary
Available via RPI.
______________________________________
Provides same format as listing display, including
inverse-assembled data.
Available via RPI and File Out.
______________________________________
____________________
Instrument
0 °C to 50 °C (32 °F to 122 °F)
Disk Media
10 °C to 40 °C (50 °F to 104 °F)
Probes/cables
O °C to 65 °C (32 °F to 149 °F)
______________________________________
Altitude
To 3000m (10,000 ft)
____________________
Humidity
8 to 80% relative humidity at
40 °C (104 °F)
______________________________________
____________________
Printing
Printer Interface Parallel interface for
Centronics compatible
printers
______________________________________
Printers
PostScript® printers and
Supported
printers that support the
HP Printer Control Language
(PCL)
______________________________________
Supported Monitor Resolutions
____________________
Time Correlation 2 ns (HP 16700A and
Resolution
16702A only)
______________________________________
Standard
Port In/Out
____________________
Graphics can be printed
directly to the printer or to a
file. Graphic files can be created in black-and-white or
color TIFF format, PostScript,
PCX, or XWD formats.
______________________________________
Connectors
BNC
______________________________________
1
640 x 480 through 1280 x 1024
(The HP 16702A has a built-in
800 x 600, 10.3” (26.2mm)
diagonal monitor.)
______________________________________
Option 003
Adds support for up to
(Must be ordered 1600 x 1200
at time of frame
purchase)
______________________________________
____________________
Intermodule Bus (IMB)
____________________
Port In
Levels
TTL, ECL, or user defined
______________________________________
Input
Resistance
4 KΩ
______________________________________
Input Voltage
–6V at –1.5 mA to
+6V at 1.6 mA
______________________________________
____________________ Port
Out
____________________
Physical
10BaseT (Ethertwist): RJ-45
LAN, IEEE 802.3
Connectors
10Base2 (Thinlan): BNC
______________________________________
Protocols
TCP/IP
Supported
NFS
CIFS (Windows® 95/98/NT)1
FTP
NTP
PCNFS
______________________________________
X-Window
Support
X Window system version
11, release 6, as a client and
server
______________________________________
____________________
Web Server
Supported from
Instrument Web
Page
Measurement status check,
remote display, installation
of PC application software,
link to HP’s Test and
Measurement site
______________________________________
PC
Pentium® (family) PC
Requirements
(200 MHz, 32 MB RAM) running Windows 95, Windows
98, or Windows NT 4.0
w/service pack 3 or higher
______________________________________
Supported Web Internet Explorer 4.0 or
Browsers (on
higher, Netscape 4.0 or
Your PC or
higher
Workstation)
______________________________________
Levels
3V TTL compatible into 50 Ω
______________________________________
Functions
Latched (latch operation is
module dependent)
Pulsed, width from 66 ns to
143 ns
______________________________________
____________________
Target Control Port
Number
of signals 8
______________________________________
Levels
3V TTL compatible
______________________________________
Connector
2 rows of 5 pins, 0.1-inch
centers
______________________________________
Graphics
User and share level control supported for
Windows NT 4.0. Share level control only
supported for Windows 95/98.
HP Remote Programming
Interface (RPI)
_________________________________________
HP RPI Overview
Typical Applications
Manufacturing Test
Data Acquisition for Offline Analysis
System Verification and Characterization
Pass/Fail Analysis
Stimulus Response Tests
_______________________________________________________________________________
Remote Programming 1. Set up the logic analyzer and save the test configuration.
Steps
2. Create a program that remotely enables you to:
• Load a test configuration
• Start the acquisition process
• Check measurement status (verify completion)
• Act on the results of the data acquisition
• Save configuration and captured data
• Export data
• Execute a compare
• Modify the trigger setup or trigger value for the next acquisition
• Access oscilloscope’s automatic measurements
_______________________________________________________________________________
Physical
Connection
Remote
programming is done via the LAN connection
_______________________________________________________________________________
_________________________________________
Requirements
HP 16600A and
HP RPI is standard with HP16600X-700X system software version
16700A Series
A.01.30.00 or higher
analysis systems
_______________________________________________________________________________
PC
Programming is done via Microsoft® ActiveX/COM automation
Pentium (family) PC with one of the following:
Windows 95
Windows 98
Windows NT 4.0 w/ Service Pack 3 or higher
Visual Basic or Visual C++ (Version 5.0 or higher)
_______________________________________________________________________________
Unix
Programming is done via procedural commands
_______________________________________________________________________________
Command Set Overview
_________________________________________
System
System Configuration Query,
Load/Save Configuration and Data,
Start/Stop Measurement,
Current Run Status
_______________________________________________________________________________
Logic Analysis
Load/Save Configuration and Data,
Modules
Trigger Setup,
Acquisition Data and Parameters
_______________________________________________________________________________
Oscilloscope
Load/Save Configuration and Data,
Modules
Trigger Setup,
Acquisition Data and Parameters,
Query Automatic Measurements
_______________________________________________________________________________
Pattern Generator
Load/Save Configuration and Data,
Load ASCII file (vectors),
Modify Vector
_______________________________________________________________________________
Emulation Module
Reset Processor,
Run Processor,
Break Processor,
Single Step
_______________________________________________________________________________
Listing Tool
Status,
Acquisition Data and Parameters,
Transfer Data (includes inverse assembled information)
_______________________________________________________________________________
Compare Tool
Execute Compare,
Set Compare Mask,
Query Compare Result
_______________________________________________________________________________
File
Out
Tool
Transfer Data to File
_______________________________________________________________________________
Additional Information
_________________________________________
Instrument Online Help Programming Information in instrument online help
_______________________________________________________________________________
Web Sites
Full remote programming documentation (pdf) available on the hard drive.
Sample programs are provided.
_______________________________________________________________________________
14
Supplemental Characteristics
for the HP 16600A, 16601A,
16602A, and 16603A
15
HP 16500 Woven Cable Model + Flying Lead
370 Ω
_________________________________________
Probes
Minimum
voltage swing
500 mV peak-to-peak
_______________________________________________________________________________
Threshold
range
±6.0 V, adjustable in 50 mV increments
_______________________________________________________________________________
1.5 pF
7.4 pF
100 KΩ
_________________________________________
1
State Analysis
Setup/hold
time
4.5/0 ns through 0/4.5 ns adjustable in 500 ps increments
_______________________________________________________________________________
Minimum
state
clock
width
3.5 ns
_______________________________________________________________________________
State clock/qualifiers
6/6 (HP 16600A/16601A/16602A)
4/4 (HP 16603A)
_______________________________________________________________________________
Time
tag
resolution
8 ns
_______________________________________________________________________________
Maximum time count
39 hours
between states
_______________________________________________________________________________
Number of machines available
2 state or 1 state/1 timing (HP 16600A, 16601A, 16602A)
1 state or 1 timing (HP 16603A)
_______________________________________________________________________________
Context
Store
block
sizes
16/32/64 states
_______________________________________________________________________________
_________________________________________
Timing Analysis
Sample period accuracy
0.01% of sample period
_______________________________________________________________________________
Channel-to-channel skew
2 ns typical
_______________________________________________________________________________
Time interval accuracy
± (sample period + channel-to-channel skew + 0.01%
of time interval reading)
_______________________________________________________________________________
_________________________________________
Triggering
Maximum
sequencer speed
100 MHz
_______________________________________________________________________________
State
sequence
levels
12
_______________________________________________________________________________
Timing
sequence
levels
10
_______________________________________________________________________________
Maximum
occurrence
counter
value
1,048,575
_______________________________________________________________________________
Pattern
recognizers
10
_______________________________________________________________________________
Range
recognizers
2
_______________________________________________________________________________
Range
width
32 bits each
_______________________________________________________________________________
Timers
2
_______________________________________________________________________________
Timer
value
range
400 ns to 500 seconds
_______________________________________________________________________________
1 Minimum setup/hold time specified for single-edge, single clock acquisition. Single-clock multiedge setup/hold window is 5 ns. Multi-clock, multi-edge setup/hold window is 5.5 ns. All setup/hold
windows are adjustable in 500 ps increments.
GROUND
Figure 15. Equivalent probe load for
the general-purpose lead set.
16
HP 16600A Series
Physical Characteristics
One Slot for Emulation Module
3.5 inch Floppy Disk Drive
16000A
LOGIC ANALYSIS SYSTEM
POWER
Up to 204
Channels for
State and Timing
Measurements
16610A MPC800 EMULATION MODULE
RESET
STOP
RUN
POD 11 / POD 12
POD 9 / POD 10
POD 7 / POD 8
POD 5 / POD 6
POD 3 / POD 4
POD 1 / POD 2
_________________
Power
HP 16600A 115/230 V, 48 to 66 Hz, 285 W max
HP 16601A 115/230 V, 48 to 66 Hz, 285 W max
HP 16602A 115/230 V, 48 to 66 Hz, 285 W max
HP
16603A 115/230 V, 48 to 66 Hz, 285 W max
______________________________________
_________________
Weight*
Max Net
Figure 16. HP 16600A Series front panel
Max Shipping
HP 16600A 10.0 kg (22.1 lb) 25.2 kg (55.6 lbs)
HP 16601A 10.0 kg (22.1 lb) 25.2 kg (55.6 lbs)
HP 16602A 10.0 kg (22.1 lb) 25.2 kg (55.6 lbs)
HP
16603A 10.0 kg (22.1 lb) 25.2 kg (55.6 lbs)
______________________________________
Mouse
* Weight of module ordered with mainframes will
add 0.9 kg (2.0 lb) per module.
Keyboard
Port IN
Port OUT
Target Control Port
One Slot for
Measurement
Modules
LAN 10Base2
RS-232
SCSI-2 Single Ended
Monitor
Parallel Port
LAN 10Base-T
Figure 17. HP 16600A Series rear panel
482.6 (19.0")
425.7 (16.76")
487.7 (19.2")
139.7 (5.50")
Figure 18. HP 16600A Series exterior dimensions. Dimensions: mm (inches).
17
HP 16700A Series
Physical Characteristics
_________________
HP 16700A 115/230 V, 48 to 66 Hz, 610 W max
Power
HP 16701A 115/230 V, 48 to 66 Hz, 545 W max
HP 16702A 115/230 V, 48 to 66 Hz, 610 W max
______________________________________
_________________
Weight*
Max Net
Max Shipping
HP 16700A 12.7 kg (27.0 lb) 34.2 kg (75.4 lbs)
HP 16701A 10.4 kg (23.0 lb) 32.0 kg (70.6 lbs)
HP
16702A 15.2 kg (32.4 lb) 36.7 kg (80.8 lbs)
______________________________________
* Weight of modules ordered with mainframes will
add 0.9 kg (2.0 lb) per module.
Parallel Port
LAN 10Base-T
Monitor
Built-in LCD Display
3.5 inch Floppy Disk Drive
SCSI-2 Single Ended
RS-232
LAN 10Base2
1
H
Five Slots for A
Measurement B
Modules
C
D
E
16702A
LOGIC ANALYSIS SYSTEM
1
2
Mouse
Target Control Port
Screen Intensity
Adjustment
Keypads for
Alpha-Numeric
Entry
On/Off Power
Switch
Keyboard
Port IN
Port OUT
Figure 19. HP 16702A front panel
HP 16701A Expansion Frame Cable Connector
Figure 20. HP 16700A and 16702A rear panel
548.64 ( 21.6" )
482.6 (19.0" )
556.3 ( 21.9" )
Two Slots for
Emulation
Modules
425.7 (16.76" )
234.2 (9.22")
Figure 21. HP 16700A, 16701A and 16702A exterior dimensions. Dimensions: mm (inches).
18
Ordering Information
Table 7. Mainframes and Testmobile
___________________________________________________________________________________
Product
#
Description
Includes
___________________________________________________________________________________
HP 16700A 1
Modular frame with five measurement module
• One DIN keyboard
slots and two emulation module slots.
• One three-button DIN mouse
__________________________________________________________________________
• One ten-conductor, flying-lead cable
HP 16702A 1
Modular frame with built-in 800 X 600
for target control port
LCD display, five measurement module
• Training kit
slots and two emulation module slots.
• Two 17-conductor flying-lead probe
__________________________________________________________________________
cables (HP 16600A Series only)
HP 16600A Series 1, 2
Built-in logic analyzer
1 measurement module slot,
1 emulation module slot
HP 16600A – 204 channels
HP 16601A – 136 channels
HP 16602A – 102 channels
HP 16603A – 68 channels
___________________________________________________________________________________
HP 16701A
Expansion frame with five
1 ft. and 3 ft. interface cables
measurement module slots and
two emulation module slots.
Requires HP 16700A or 16702A
___________________________________________________________________________________
HP 1184A
Testmobile
Drawer, keyboard tray, mouse tray,
strap for stabilizing monitor
___________________________________________________________________________________
RECOMMENDATIONS:
1 For HP 16700A and all 16600A Series mainframes, order a monitor (option 001) and at least one CD-ROM drive (option 004). For the HP 16702A, order at
least one CD-ROM drive (option 004). The CD-ROM drive is necessary to install future system software upgrades.
2 Each HP 16600A Series mainframe includes two sets of 17-channel probe leads (34 channels total). If you require additional pairs of probe leads,
order option 010.
Table 8. Mainframe Options
___________________________________________________________________________________
Option #
Description
HP 16700A or 16702A
HP 16701A
HP 16600A Series
___________________________________________________________________________________
001
Add 17-inch 1280 x 1024 monitor and cable
√
√
___________________________________________________________________________________
Performance system upgrade — 160 Mbyte
√
√
total system RAM, 2 Mbyte total video RAM.
(Must order at time of frame purchase)
___________________________________________________________________________________
004
Add CD-ROM Drive
√
√
___________________________________________________________________________________
010
Add two sets of 17-channel probe leads
√
(34 channels)
___________________________________________________________________________________
0B3
Add service guide
√
√
___________________________________________________________________________________
1CM
Add
rack-mount
kit
√
√
√
___________________________________________________________________________________
ABJ
Japanese
Localization
√
√
___________________________________________________________________________________
W17
Convert one year return-to-HP warranty to
√
√
√
one year on-site warranty
___________________________________________________________________________________
W30
Extend standard warranty to three year
√
√
√
return-to-HP warranty
___________________________________________________________________________________
W50
Extend standard warranty to five year
√
√
√
return-to-HP warranty
___________________________________________________________________________________
003
19
Table 9. Related HP Literature
Refer to the documents below for more information on HP logic analysis
systems and accessories.
Publication Title
Publication Type
HP Publication
Number
_______________________________________________________________________________
State and Timing Analyzers for
Product overview
5966-3367E
HP Logic Analysis Systems
_______________________________________________________________________________
Oscilloscope Modules for
Product overview
5966-3150E
HP
Logic Analysis Systems
_______________________________________________________________________________
HP 16522A 200 MVector/sec Pattern
Product overview
5964-2250E
Generator
Module
_______________________________________________________________________________
Processor and Bus Support for
Configuration guide
5966-4365E
HP
Logic
Analyzers
_______________________________________________________________________________
Post-processing
Tool Sets
Product overview
5966-3147E
_______________________________________________________________________________
Probing Solutions for HP Logic
Product overview
5968-4632E
Analysis
Systems
_______________________________________________________________________________
Warranty
HP hardware products are warranted against defects in materials and
workmanship for a period of one year from date of shipment. If you
send us a notice of such defects during the warranty period, we will
either repair or replace hardware products that prove to be defective.
Some newly manufactured HP products may contain remanufactured
parts, which are equivalent to new in performance.
HP software and firmware products that are designated by HP for use
with a hardware product are warranted for a period of one year from
date of shipment to execute their programming instructions when properly installed. If you send us notice of defects in materials workmanship
during the warranty period, we will repair or replace these products, so long
as the defect does not result from buyer-supplied hardware or interfacing.
The warranty period is controlled by the warranty statement included with
the product and begins on the date of shipment.
For more information about the
HP 16600A and 16700A Series logic
analysis systems, visit our web site at:
http://www.hp.com/go/las-data
For more information about
Hewlett-Packard Test & Measurement
products, applications, services,
and for a current sales office listing,
visit our web site at:
http://www.hp.com/go/tmdir
You can also contact one of the following centers and ask for a test and
measurement sales representative.
United States:
Hewlett-Packard Company
Test and Measurement Call Center
P.O. Box 4026
Englewood, CO 80155-4026
1 800 452 4844
Canada:
Hewlett-Packard Canada Ltd.
5150 Spectrum Way
Mississauga, Ontario
L4W 5G1
(905) 206 4725
Europe:
Hewlett-Packard
European Marketing Centre
P.O. Box 999
1180 AZ Amstelveen, The Netherlands
(31 20) 547 9900
Japan:
Hewlett-Packard Japan Ltd.
Measurement Assistance Center
9-1, Takakura-Cho, Hachioji-Shi,
Tokyo 192, Japan
Tel: (81) 426 56 7832
Fax: (81) 426 56 7840
Latin America:
Hewlett-Packard
Latin American Region Headquarters
5200 Blue Lagoon Drive
9th Floor
Miami, Florida 33126
U.S.A.
Tel: (305) 267-4245/4220
Fax: (305) 267-4288
Australia/New Zealand:
Hewlett-Packard Australia Ltd.
31-41 Joseph Street
Blackburn, Victoria 3130, Australia
Tel: 1 800 629 485 (Australia)
0800 738 378 (New Zealand)
Fax: (61 3) 9210 5489
Asia Pacific:
Hewlett-Packard Asia Pacific Ltd.
17-21/F Shell Tower, Times Square,
1 Matheson Street, Causeway Bay,
Hong Kong
Tel: (852) 2599 7777
Fax: (852) 2506 9285
Netscape is a U.S. trademark of Netscape Communications Corp.
Microsoft is a U.S. registered trademark of Microsoft Corp.
Pentium is a U.S. registered trademark of Intel Corp.
PostScript is a trademark of Adobe Systems Incorporated.
Windows 95, 98 and NT are U.S. registered trademarks of Microsoft Corp.
Unix is a registered trademark of the Open Group.
Technical information in this document is
subject to change without notice.
Printed in the U.S.A.
5966-3107E
05/99