Advertisement
Advertisement
DATA SHEET CROSS TECHNOLOGIES, INC. REV C 05/24/10 2017-05 Up/Downconverter, 950-1525 MHz, 140 MHz IF The 2017-05 L-band Up/Downconverter converts 140 MHz to 950-1525 MHz (Up) and 950-1525 MHz to 140 MHz (Down) in 1 MHz steps with low group delay and flat frequency response. Synthesized local oscillators (LO) provide frequency selection. Multi-function push button switches select the RF frequency, gain, and other parameters. Front panel LEDs provide indication of DC power (green), PLL alarm for up and downconverters (red), remote operation (yellow), and upconverter mute (yellow). Gain is manually controlled over a -10 to +30 dB range for the upconverter and over a 0 to +50 dB range for the downconverter as adjusted by the front panel multifunction push-button switches. Remote operation allows selection of frequency and gain. Parameter selection and frequency and gain settings appear on the LCD display. Connectors are BNC female for IF and the optional external reference input and output, and Type F female for RF. LNB or SSPB +24 VDC and 10 MHz reference can be inserted on the RF lines as added options. A high stability (±0.01ppm) option is also available. It is powered by a 100-240 ±10% VAC power supply & housed in a 1.75” X 19" X 16” 1RU chassis. MODEL 2017 DOWNCONVERTER UPCONVERTER U F=1525 G=10 D F=1450 G=25 UP/DOWNCONVERTER MENU CROSS TECHNOLOGIES INC. EXECUTE ALARM REMOTE POWER MUTE ALARM Front Panel EQUIPMENT SPECIFICATIONS* DOWNCONVERTER Input Characteristics (RF) Impedance/Return Loss 75 /12 dB Frequency 950 to 1525 MHz Noise Figure, max. 15 dB (max gain) Input Level Range -70 to -20 dBm Input 1dB compression -15 dBm Output Characteristics (IF) Impedance/Return Loss 75/18 dB Frequency 140 ± 36 MHz Output level/max linear -20 dBm / -10 dBm Output 1 dB compression -5 dBm Channel Characteristics Gain range (adjustable) 0 to +50 dB Frequency Sense Inverting or Non-inverting (selectable) UPCONVERTER Input Characteristics (IF) Impedance/Return Loss 75 /18 dB Frequency 140 ± 36 MHz Input Level Range -40 to -10 dBm Output Characteristics (RF) Impedance/Return Loss 75/12 dB Frequency 950 to 1525 MHz Output level -20 to 0 dBm Output 1 dB compression +5 dBm Channel Characteristics Gain range (adjustable) -10 to +30 dB Frequency Sense Non-inverting UP AND DOWNCONVERTER Channel Characteristics Frequency Response ±1.5 dB, 950 to 1525 MHz ; ± 0.5 dB, 72 MHz BW Spurious Response < -50 dBc, in band Group Delay, max 0.0035 ns/MHz2 parabolic; 0.025 ns/MHz linear; 1 ns ripple Synthesizer Characteristics Frequency Accuracy ± 1.0 ppm internal reference (±.01 ppm, option H) Frequency Step 1 MHz (125 kHz, option X) 10 MHz In/Out Level 3 dBm ± 3 dB (option E only) Phase Noise @ F (Hz) > dBC/Hz Controls, Indicators Freq/Gain Selection Power; Alarm; Up Mute Remote Other RF, IF Connectors 10MHz Connectors Alarm/Remote Connector Size Power 100 -70 1K -80 10K -90 100K -100 Direct readout LCD; manual or remote selection Green LED; Red LED; Yellow LED Yellow LED; RS232C, 9600 baud (RS485, option Q) Available Options E - External 10 MHz ref input & output H - High Stability (±0.01) Internal Ref Q - RS485 Remote Interface L - LNB Voltage (+24VDC, 0.4 amps max) V - SSPB Voltage (+24VDC, 2.5 amps max) T - Temperature Sensor X - 125 kHz Frequency Steps Z - 0.1 dB Attenuator Steps on Upconverter Connectors/Impedance B - 75 BNC (RF), 75 BNC (IF) C - 50 BNC (RF), 75 BNC (IF) D - 50 BNC (RF), 50 BNC (IF) N - 50 N-type (RF), 75 BNC (IF) M - 50 N-type (RF), 50 BNC (IF) Type F (female), BNC (female) BNC (female), 50/75 (option E only) DB9 (female) - NO or NC contact closure on Alarm 19 inch, 1RU standard chassis 1.75" high X 16.0" deep 100-240 ±10% VAC, 47-63 Hz, 45 W max *10˚C to 40˚C; Specifications subject to change without notice CROSS TECHNOLOGIES, INC. 6170 Shiloh Road, Alpharetta, Georgia 30005 770-886-8005, FAX 770-886-7964 www.crosstechnologies.com ">
Advertisement