VFDA4X04-D230-PCM QUICK START GUIDE Variable-frequency drives for 3-phase and single-phase AC motors C501 C502 D S3 S2 S1 E1 E2 TB501 JMP504 4mA 1 2 IC502 J501 JMP505 1 2 T501 503 T502 MIN JMP501: SELECT INPUT TYPE 1 & 2 = CURRENT INPUT 2 & 3 = VOLTAGE INPUT 1 = 0 - 5 VDC 2 = 0 - 10 VDC 3 = 4 - 20 mA C507 RESTART C508 JMP506 J503 COAST T JMP503 BRAKE J502 R1 IC11 115V FU502 230V JMP501 FU501 TB502 AC LINE CONNECTIONS M I N A R I K D R I V E S w w w . m i n a r i k d r i v e s . c o m 14300 De La Tour Drive, South Beloit, IL 61080; Phone: (800) MINARIK (646-2745); Fax: (815) 624-6960 Document Number: 250-0373, Revision 1; Printed in the U.S.A. - November 2003 Copyright 2003 by Minarik Corporation - All rights reserved. No part of this document may be reproduced or transmitted in any form without written permission from Minarik Corporation. The information and technical data in this document are subject to change without notice. Minarik Corporation and its Divisions make no warranty of any kind with respect to this material, including, but not limited to, the implied warranties of its merchantability and fitness for a given purpose. Minarik Corproation and its Divisions assume no responsibility for any errors that may appear in this document and make no commitment to update or to keep current the information in this document. mvd110503 C A L I B R A T I O N S E T T I N G S S P E C I F I C A T I O N S 4mA ZERO SET The 4mA ZERO SET trimpot sets zero speed when a 4-20mA input signal is used. Maximum Speed (MAX) The MAX setting determines the motor speed when the speed adjust potentiometer is turned full CW. Rotate the speed adjust potentiometer full CW. Using a hand-held tachometer or analog frequency meter as a reference, adjust the MAX trimpot until the desired speed or frequency is reached. Minimum Speed (MIN) The MIN setting determines the motor speed when the speed adjust potentiometer is turned full CCW. It is factory set to zero speed. The MIN setting range is 0 to 30% MAX setting. To calibrate MIN, turn the speed adjust potentiometer CCW. Adjust the MIN trimpot until the motor has stopped (for zero speed setting), or is running at the desired minimum speed. Deceleration Time (DECEL) The DECEL setting determines the time the motor takes to ramp to a lower speed. Decel is factory set for the fastest deceleration time (full CCW). To set the deceleration time: 1. Set the speed adjust potentiometer to maximum (full CW) and wait for the motor to come to maximum speed. 2. Set the speed adjust potentiometer to minimum speed (full CCW) and note the time the motor takes to decelerate to minimum speed. 3. If the deceleration time differs from the desired time, adjust the DECEL trimpot until the desired time is reached. Rotating the DECEL pot CW increases the deceleration time. Acceleration Time (ACCEL) The ACCEL setting determines the time the motor takes to ramp to a higher speed. ACCEL is factory set for the fastest acceleration time (full CCW). To set acceleration time: 1. Set the speed adjust potentiometer to zero (full CCW) and wait for the motor to come to a stop (or minimum speed). 2. Set the speed adjust potentiometer to maximum speed (full CW) and note the time the motor takes to accelerate to maximum speed. 3. If the acceleration time differs from the desired time, adjust the ACCEL trimpot until the desired time is reached. Rotating the ACCEL trimpot CW increases the acceleration time. TORQUE LIMIT The TORQUE LIMIT setting determines the maximum torque for accelerating and driving the motor. TORQUE LIMIT is factory set at 100% of rated motor current. Althought the TORQUE LIMIT trimpot can be set up to 100% of the drive nameplate rating, continuous operation beyond the drive nameplate rating may cause damage to the motor and/or drive. 1-Phase Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .* 115/230 VAC 1 or 3 -Phase Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230 VAC Maximum Horsepower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 HP Maximum Continuous Output Current . . . . . . . . . . . . . . . . . . . . . . † 4.0 AC AC Amps In . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 / 10 amps AC Voltage Input Range . . . . . . . . . . . . . . . . . . . . . . .115/230 VAC ± 10% 50/60 Hz single phase Standard Carrier Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 KHz Output Frequency Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0 - 120 Hz Adjustable Maximum Output Frequency Range . . . . . . . . . . . . .30 - 120 Hz Acceleration Time Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 - 12 secs Deceleration Time Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 - 12 secs Analog Input Voltage Range (S1 [-] to S2 [+]) . . . . . . . . . . . . . . 0 - 5 VDC, 0 - 10 VDC, 4 - 20 mA Input Impedance, S1 to S2 . . . . . . . . . . . . . . . . . . . . . . . . . . .~ 100K ohms Vibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.5G max (20 - 50 Hz) 0.1G max (> 50 Hz) Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.2 lbs Ambient Operating Temperature Range . . . . . . . . . . . . . . . . . . .10° - 40° C To set the torque limit: 1. With no power applied to the drive, connect a (true RMS) ammeter in series with one of the motor leads. 2. Set the TORQUE LIMIT trimpot to full CCW. 3. Carefully lock the motor shaft. Ensure that the motor is firmly mounted. 4. Apply line power. The motor should be stopped. 5. Set the speed adjust potentiometer to maximum speed. The motor should remain stopped. 6. Slowly rotate the TORQUE LIMIT trimpot clockwise (CW) until the ammeter reads 100% of maximum motor current. 7. Set the speed adjust potentiometer to zero speed. 8. Remove power from the drive. 9. Remove the lock from the motor shaft. 10. Remove the ammeter in series with the motor lead. BRAKE CURRENT The BRAKE CURRENT setting controls the amount of braking current applied, ranging from 0 - 100% of drive rating. To set brake current: Rotate the BRAKE CURRENT trimpot CW to increase the amount of current applied. Rotate the BRAKE CURRENT trimpot CCW to decrease the amount of current applied. BRAKE TIME * Connect only 115 VAC line input to the 115 VAC terminals. Application of 230 VAC line input when set for 115 VAC will result in severe damage to the motor and drive. The BRAKE TIME setting controls the amount of time brake current is applied to the drive. The BRAKE TIME range is 1 to 10 seconds. † Derate current by 2% per degree if the operating temperature is above 40°C. Under no circumstances may the ambient temperature exceed 55°C. To set the brake time: Rotate the BRAKE TIME trimpot CW to increase the amount of time the drive takes to break. Rotate the BRAKE TIME trimpot CCW to decrease the amount of time the drive takes to brake. J U M P E R S E T T I N G S JMP504 Slip Compensation (SLIP COMP) The SLIP COMP setting controls speed regulation during load changes. The SLIP COMP range is 0 - 5 Hz at base speed and load. JMP504 1 2 1 & 2 for Voltage Input 2 & 3 for Current Input 3 Increase the motor speed to maximum. Slowly load the motor until the AC phase current is at its maximum (100%). If the motor shows any signs of slowing, rotate the SLIP COMP trimpot CW until the motor shaft rotates at the original set speed. BOOST The BOOST setting is used to increase motor torque at low speeds. The minimum setting is sufficient for most applications and does not need to be adjusted. If the motor stalls or runs too slowly due to excessive slip at very low speeds (below 10 Hz), the boost trimpot may need adjustment. To adjust the BOOST setting: 1. Run the motor at the lowest continuous frequency/speed required. 2. Monitor the motor phase current (with a true RMS meter) while very slowly turning the BOOST trimpot CW until the motor operates properly, or 100% of the motor nameplate current is reached. Note: Use the absolute minimum amount of BOOST necessary to achieve proper motor operation. Improper use of the BOOST feature may cause motor and/or drive overheating and failure. If proper motion operation cannot be achieved with the above procedure, please contact your Miniark representative for assistance. JMP503 JMP505 TRIP JMP505 1 2 1 = 0 - 5 VDC INPUT 2 = 0 - 10 VDC INPUT 3 = 4 - 20 mA INPUT 3 1 COAST T 2 3 1 2 3 JMP503 RESTART 1 & 2 to Trip 2 & 3 to Restart TRIP: Drive has a low voltage fault & must be manually re-enabled to restart. RESTART: Drive has a low voltage fault & will momentarily stop then auto-restart when input voltage returns to minimum level. JMP506 JMP506 JMP501 UV 1 & 2 to Coast 2 & 3 to Brake BRAKE 115V 230V JMP501 1 2 1 & 2 for 115VAC 2 & 3 for 230VAC 3 115 = 115 VAC INPUT DOUBLER MODE 230 = 230 VAC INPUT MODE WARNING! Using 230 VAC input in Doubler mode will damage the drive!
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement