PIN-BCL500i-en

PIN-BCL500i-en
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
BCL 500i bar code reader
The new generation with
a variety of integrated interfaces
Now also with
P R O D U C T I N F O R M AT I O N
inside
E-mail:[email protected]
Site web : www.hvssystem.com
Connectivity
at its finest.
Bar code reader with integrated fieldbus connectivity.
The BCL 500i series.
Integrated networkability—this is one of the key features of the future-oriented
bar code readers of the BCL 500i series. A variety of available integrated fieldbus
interfaces greatly simplifies the handling of the systems since time-consuming
connections via gateways are eliminated. Commissioning is as simple as
connecting to the respective fieldbus system, and configuration can be performed
without any additional software.
The new BCL 558i now also with integrated Ethernet/IP.
An innovation—the BCL 558i has expanded the BCL 500i series with an
integrated Ethernet/IP interface, which enables easy operation and direct
communication via the control.
Via an integrated switch, each BCL 5x8i with an Ethernet-based interface can
also be connected to other bar code readers in a line or ring structure.
Depending on the interface and control, should it be necessary to exchange
a BCL 500i device, the configuration can automatically be loaded onto the
replacement device. The connection is performed via a standardized M12 plug
and the available ready-made cables. These make wiring economical,
transparent and fail-safe.
!
NENW
et IP
Ether e
insid
multi Net
Simple handling.
Large variety of interfaces and models.
The main advantages of the BCL 500i series.
Integrated fieldbus and Industrial Ethernet connectivity:
PROFIBUS, PROFINET, ETHERNET/IP, ETHERNET TCP/IP and UDP, MULTINET
Code reconstruction technology (CRT): Facilitates identification of soiled or
damaged codes
High scanning rate of 800–1,200 scans/s (adjustable):
Facilitates identification even at very high conveyor speeds
High depth of field and large opening angle:
For wide transport systems
Simple commissioning and connection using
M12-Ultra-Lock™ connection technology and
intelligent fastening concept
Intuitive, multi-language display with menu navigation
Convenient configuration with the integrated webConfig tool
via USB
Various models: Single line, deflection mirror,
oscillating mirror for flexible use
Optional heating models to -35 °C
BCL 500i series
Interface models.
BCL 500i
BCL 501i
multiN e t
BCL 504i
multiN e t
Integrated network master
multiNet slave on the
for controlling the Leuze
Leuze network
multiNet plus network
Integrated Ethernet
Direct configuration
TCP/IP and UDP
network can be set via
Baud rate 10/100 MBaud
the display
PROFIBUS user addresses
can be set via the display
Number of slave
participants can be set
via the display
BCL 548i
Integrated PROFIBUS
via PROFIBUS
User addresses in the
Stand-alone operation
BCL 508i
BCL 558i
NEW
Integrated PROFINET
Integrated Ethernet
Integrated switch
Integrated switch
Direct configuration via
Configuration of the
PROFINET
communication via
Ethernet/IP
!
Configuration made easy:
BCL 500i webConfig.
The fast track to custom
bar code reader configuration.
The Leuze electronic webConfig tool integrated in the device provides a web
technology-based graphic user interface for configuration of the BCL 500i series
bar code readers which is totally independent of the operating system.
Through the use of HTTP as communication protocol and by using only standard
technologies on the client side (HTML, JavaScript and AJAX), it is possible to
operate the webConfig tool on any PC with a browser without the need for a
direct internet connection. The connection to the USB service interface of the
BCL 500i series bar code readers is established via the PC-side USB interface
using a USB cable.
The webConfig tool is accessed via a login which, depending on
the authorizations of the currently logged-in user, permits varying
levels of access to the individual pages and their contents.
The individual parameters are – where useful – graphically
displayed in order to better illustrate the meaning of the what are
often perceived as abstract parameters.
The result is an easy-to-use and practically-oriented user interface!
The user interface is divided into various function groups to
optimally support the user in the various operating situations.
Limitless possibilities
for your applications.
BCL 500i
Technical data
Line scanner
Type
Line scanner without heating*
Optical data
Light source
Beam exit
Scanning rate
Useful opening angle
Optics models / resolution
Read distance
Laser safety class
Bar code data
Code types
Number of bar codes per scan
Stand alone and multiNet Plus Master
Electrical data
Interface type
Protocols
Baud rate
Data formats
Service interface
Operating voltage
Power consumption
Operating and display elements
Display
Keyboard
LEDs
Mechanical data
Protection class
Weight
Dimensions (W × H × D)
Housing
Environmental data
Operating temperature range
Storage temperature range
Air humidity
Vibration
Shock
Continuous shock
Electromag. compatibility
Line scanner with oscillating mirror
Type
Line scanner with oscillating mirror without
heating*
Optical data
Beam exit
Oscillation frequency
Max. swivel angle
Electrical data
Power consumption
Mechanical data
Weight
Dimensions (W × H × D)
Line scanner with deflection mirror
Type
Line scanner with deflection mirror without
heating*
Optical data
Beam exit
Max. optical adjustment range of the beam exit
Electrical data
Power consumption
Mechanical data
Weight
Dimensions (W × H × D)
1 x RS232/422 and 1 x RS485
each encoded to M12 (B)
Leuze Standard, Leuze multiNet plus,
ACK / NAK, 3964 (R) RK 512, Xon / Xoff
4,800 ... 115,400 Baud
Data bits: 7,8 / Stop bits: 1,2
Parity: None, Even, Odd
Stand alone and multiNet Plus Master
Stand alone and multiNet Plus Master
* Data for scanners with optics heating: see technical description, download under www.leuze.com
BCL 501i
BCL 504i
BCL 508i
Specifications of the line scanners without heating
BCL 548i
BCL 558i
multiNet Plus Slave
PROFIBUS DP
PROFINET
Ethernet/IP
Ethernet
NEW
!
Laser diode = 650 nm / 655 nm (red light)
Front
1,000 scans/s (adjustable in the range 800 -1,200 scans/s)
Max. 60 °
High Density (N): 0.25 – 0.5 mm; Medium Density (M): 0.35 – 0.8 mm; Low Density (F): 0.5 – 1.0 mm; Ultra Low Density (L): 0.7 – 1.0 mm
See reading field curves
2 acc. to EN 60825-1, CDRH (U.S. 21 CFR 1040.10)
2/5 Interleaved, Code 39, Code 128, EAN / UPC, Codabar, Code 93, RSS 14
6
1 x RS485 encoded to 2 x M12 (B)
Leuze Standard, Leuze
multiNet plus
4,800 ... 115,400 Baud
Data bits: 7,8 / Stop bits: 1,2
Parity: None, Even, Odd
1 x RS485 encoded to 2 x M12 (B)
Ethernet encoded to 2 x M12 (D)
PROFINET encoded to 2 x M12 (D)
Ethernet encoded to 2 x M12 (D)
PROFIBUS DP
Ethernet, TCP / IP / UDP
PROFINET / RT, TCP / IP
Ethernet/IP
9.6 Kbaud – 12 MBaud
10 / 100 MBaud
10 / 100 MBaud
10 / 100 MBaud
Slave DPV1
–
–
–
USB 1.1 compatible, A-coded
10 ... 30 V DC (SK III, class 2)
Approx. 10 W
Monochromatic graphical display, 128 × 64 pixel, background lighting
4 buttons
2 LEDs for power (PWR) and bus state (BUS), two-colored (red/green)
IP 65
1.1 kg
63 × 123.5 × 106.5 mm
Diecast aluminum
0 °C – +40 °C
-20 °C – +70 °C
Air humidity max. 90 % rel. humidity, non-condensing
IEC 60068-2-6, test FC
IEC 60068-2-27, Ea test
IEC 60068-2-29, test Eb
EN 55022, EN 61326-1; IEC 61000-6-2 (includes IEC 61000-4-2, -3, -4, -5 and -6)
Technical data same as for line scanner without heating, however with the following differences:
multiNet Plus Slave
PROFIBUS DP
Ethernet
PROFINET / RT, TCP / IP
Ethernet/IP
Lateral zero position at an angle of 90°
0-10 Hz (adjustable, max. frequency is dependent on set swivel angle)
+/- 20° (adjustable)
Approx. 14 W
1.5 kg
84 × 173 × 147 mm
Technical data same as for line scanner without heating, however with the following differences:
multiNet Plus Slave
PROFIBUS DP
Ethernet
Optical data—beam exit with lateral zero position at an angle of 90°
+/- 10° (adjustable via display or software)
Approx. 11 W
1.4 kg
84 × 173 × 147 mm
PROFINET / RT, TCP / IP
Ethernet/IP
The reading field curves
Reading field curve for N-optics
Reading field curve for M-optics
Line scanner with/without deflection mirror or oscillating mirror
BCL 500/501/504/508i SN 100/102
BCL 500/501/504/508i SM 100/102
400
400
m = 0,25
300
m = 0,35
300
m = 0,3
m = 0,35
200
m = 0,5
m = 0,8
…
m = 1,0
200
-100
-200
-300
-400
100
200
300
400
500
600
700
800
900
1000
1100
m = 0,5
m = 0,8 … 1,0
100
m = 0,35
Reading field width [mm]
m = 0,5
m = 0,3
m = 0,35
100
m = 0,25
Reading field width [mm]
m = 0,5
-100
-200
-300
-400
Read distance [mm]
100
200
300
400
500
600
700
800
900
1000
1100
Read distance [mm]
Line scanner with oscillating mirror (lateral reading curve)
BCL 500/501/504/508i ON 100
BCL
500/501/504/508i
OM
100
BCL
500/501/504/508i
OM
100
400
400
400
m = 0,35
m = 0,35
m = 0,25
m = 0,35
-200
-300
0
100
200
300
Read distance [mm]
400
500
600
700
800
900
1000
= 0,8
m =m0,8
… …
= 1,0
m =m1,0
m = 0,8 … 1,0
m = 0,8 … 1,0
100
100
m = 0,5
m = 0,5
m = 0,5
m = 0,3
m = 0,35
-100
m = 0,5
m = 0,5
200
200
Reading field height [mm]
m = 0,5
100
m = 0,25
Reading field height [mm]
200
-400
-100
300
300
m = 0,3
m = 0,35
m = 0,35
300
-100
-100
-200
-200
-300
-300
-400
-400
-100
-100
00
100
100
200
200
300
300
Read distance [mm]
400
400
500
500
600
600
700700
800800
900900
1000 1100
1100
1000
Reading field curve for F-optics
Reading field curve for L-optics
Line scanner with/without deflection mirror or oscillating mirror
BCL 500/501/504/508i SF 100/102
700
m = 0,5
600
BCL 500/501/504/508i SL 102
800
500
m = 0,8
400
m = 1,0
m = 0,7
600
m = 0,8
400
-100
-200
-300
-400
-500
-600
-700
100
200
300
400
500
600
700
800
900 1000 1100 1200 1300 1400 1500 1600 1700
Read distance [mm]
m = 1,0
m = 0,8
200
m = 1,0
m = 1,0
m = 0,8
100
m = 0,7
Reading field width [mm]
200
m = 0,5
Reading field width [mm]
300
-200
-400
-600
-800
0
200
400
600
800
1000
1200
1400
1600
1800
2000
2200
2400
2600
Read distance [mm]
Line scanner with oscillating mirror (lateral reading curve)
BCL 500/501/504/508i OF 100
BCL 500/501/504/508i OL 100
700
1000
m = 0,5
600
500
m = 0,8
400
m = 1,0
800
m = 0,7
600
m = 0,8
-200
-300
-400
-500
-600
-700
-100
0
100
200
300
400
500
Read distance [mm]
600
700
800
900 1000 1100 1200 1300 1400 1500 1600 1700
m = 1,0
-100
m = 1,0
200
m = 0,8
m = 1,0
m = 0,8
100
m = 0,7
200
Reading field height [mm]
400
m = 0,5
Reading field height [mm]
300
-200
-400
-600
-800
-1000
0
200
400
600
800
Read distance [mm]
1000
1200
1400
1600
1800
2000
2200
2400
2600
Switching Sensors
Optical Sensors
Ultrasonic Sensors
Fiber Optic Sensors
Inductive Switches
Forked Sensors
Light Curtains
Special Sensors
Measuring Sensors
Distance Sensors
Sensors for Positioning
3D Sensors
Light Curtains
Forked Sensors
Products for Safety at Work
Optoelectronic Safety Sensors
Safe Locking Devices and Switches
Safe Control Components
Machine Safety Services
Identification
Bar Code Identification
2D-Code Identification
RF Identification
Data Transmission/
Control Components
MA Modular Interfacing Units
Data Transmission
Safe Control Components
Leuze electronic GmbH + Co. KG
In der Braike 1
D-73277 Owen/Germany
Phone +49 7021 573-0
Fax
+49 7021 573-199
[email protected]
www.leuze.com
en 02-2013/08 50113106
Industrial Image Processing
Light-Section Sensors
Smart Camera
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF