CAT NO.

XWEB

Project Name:

Location:

IDN#

Catalog#

XWEB Gateways

Quanity:

Internet Monitoring and Control Systems for HACCP and Energy Savings

The XWEB is a Linux based WebServer that acts as a gateway to a Local Area Network of CX appliance controls and monitoring devices for Foodservice, Restaurants, C-Stores, Warehouses, Supermarkets, Retail installations where Food Safety and Energy Savings are sought. The XWEB will record, monitor and analyze data and status, manage alarms, and optimize commercial appliances using CX controllers in applications such as refrigeration, walk-ins, food warming/ovens, HVAC, lighting and Energy Monitoring.

The XWEB is an economical scalable solution for monitoring, monitoring and control or full control and supervising.

3/09

XWEB System Features

• Recording of all temperatures and output status in a minimum of 15 minutes intervals, storing for 1 year.

• Up to 247 addresses of controls and/or monitoring devices.

• Manage alarms

• Linux OS system for stability

• RS485 two wire network (up to 1 mile wired and optional

1500ft RF wireless network).

• Access to System is via Standard Browser such as

Explorer ® , Firefox, Safari, etc.

Built-in Web Pages include:

• Home Page

• Single view

• RunTime

• Layout

• Graphs

• Alarms

• Scheduler

• Parameters

• Supervision

• CRO

APPROVALS:

DATE:

XWEB300D

XWEB500D

XWEB500

XWEB3000

XWEB5000

CAT NO.

XWEB XWEB Gateways

MODEL XWEB OVERVIEW

The product is a Linux based WebServer that serves as a gateway to a

LAN of controls for Foodservice, Restaurants, C-Stores, Warehouses,

Supermarkets, Retail or other applications. Recording and monitoring of data, alarms, status and interface with commercial appliances, such as refrigeration, walk-ins, food warming/ovens, HVAC, lighting and

Energy Monitoring are desired.

MOUNTING

The product is either Din-Rail mounted, typically in an enclosure, desk mounted in an office or rack mounted, depending on the model.

NETWORK

The product connects to a two wire RS485 network in a daisy chain up to one mile. Wireless connection is also acceptable. The protocol for the network is MODBUS-RTU. The network will include a total address count from 6 to 247, depending on requirements. A minimum of 1 year of data can be stored (when sampling every 15 minutes).

POWER

The product shall be powered by 24Vac /120Vac/230Vac @50/60Hz.

INPUTS

The XWEB has 6/18/36/50/100 or 247 control and monitoring nodes (addresses) depending on the model. Units with at least 36 inputs also have 1digital input.

OUTPUTS

The XWEB has one System Alarm dry contact 8A SPDT Relay. Units with at least 36 inputs shall also have two alarm dry contacts 8A

SPDT Relays.

COMMUNICATIONS

The unit has an RJ45 Ethernet connection to be connected to a LAN or the Internet using a Static IP address. Optional communications via Modem or GSM modem. Access will be via Standard Browser

(such as Explorer ® , Firefox or Safari). It has front and backside security and password protection. No software is required.

WEB PAGES

• Home Page • Single View • Parameter Programming • Run Time

• Graphics/Uploading data

36 and up also includes:

• Layout • Scheduler • Global Commands • Performance Meter

247 version includes:

• Supervision • CRO 50 & 247

XWEB300-6/18

XWEB500-100/XWEB500D-36/50/100

XWEB3000-247

XWEB5000-247

XWEB3000 /

XWEB5000

XWEB500

XWEB300D /

XWEB500D

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

WARRANTY

ONE YEAR

WEISS INSTRUMENTS, INC., 905 WAVERLY AVE., HOLTSVILLE, NEW YORK 11742 • 631.207.1200 • FAX: 631.207.0900

Email: [email protected]

www.weissinstruments.com

HOLTSVILLE, NEW YORK 11742

631-207-1200 • FAX: 631.207.0900

www.weissinstruments.com

CAT NO.

XJP60D

Project Name:

Location:

IDN#

Catalog#

I/O Probe Monitoring Modules

Quanity:

Record up to 6 temperatures (PSI or %RH)

The XJP60D is a network module that can accept up to 6 NTC Temperature inputs or 4...20mA and

0/10V analog inputs from Pressure, Humidity or other inputs. The unit transfers the data to an XWEB over a RS485 Network.

The serial communication enables the XJP60D to connect to XWEB Monitoring Systems and other open systems using ModBus-RTU.

The unit includes 3 Digital Inputs typically used for Door Alarms using a magnetic door switch, or a CT to monitor other events. Alarm setpoints with delays can be assigned to each probe.

Applications include Monitoring of:

• Walk-in Coolers and Freezers

• Reach - in's

• Food Warming Cabinets

• A/C and Outdoor temps

• Pressure and Humidity

• Level or flow (with any 4...20mA or 0/10V output)

Probe Options:

• 18NB–NTC–1.5m

1/4"x1/8" Nickle Plated Brass 5Ft.

• XH10P

4...20mA output 10–90% RH

• PP11 –7/160 psi

• PP30 0/435 psi

4...20mA output

18NB – NTC

XH10P

PP11

3/09

MODEL RC

APPROVALS:

DATE:

CAT NO.

XJP60D I/O Probe Monitoring Modules

MODEL XJP60D OVERVIEW

The Monitor has three status LED’s: Power, Rx/Tx and Alarm. The

Monitor has either 6 NTC probes or 6 4...20mA or 0/10V inputs and

3 Digital inputs. Alarm Setpoints with delays can be assigned to each probe. It shall have a RS485 Connection.

MOUNTING

The product is 4DIN RAIL or wall mounted in a DinBox and shall have

IP65 protection from the front.

SENSORS

The product has up to 6 NTC Thermistor temperature probes, range of –58/230°F, which can be extended up to 300ft. using standard thermostat wire or 6 4...20mA or 0/10V inputs.

POWER

The product shall be powered by 24Vac and use a class 2 cULus transformer.

INPUTS

The control shall have 3 Digital inputs (open/closed circuit) that is typically used with a magnetic door switch to indicate door openings or a CT to record events such as defrost or fan failure.

OUTPUTS

The XJP60D has a RS485 Serial communications output to be connected to a XWEB System.

COMMUNICATIONS

The Control shall have a RS485 Serial Port.The two way communication protocol shall be MOD-BUS-RTU. The Module shall have a settable serial address from 1 to 247. MOD-BUS Comments,

Registers and Hex Codes are free and open, and are available on request.

PROGRAMMING

The control is pre-programmed and pre-addressed for NTC temperature recording applications. The temperature shall be recorded every

15 minutes. There shall be 2 levels of control parameters that are password protected. A Hot Key flash memory device can upload or download a program to the unit. The program shall remain in internal memory without power.

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

WARRANTY

ONE YEAR

WEISS INSTRUMENTS, INC., 905 WAVERLY AVE., HOLTSVILLE, NEW YORK 11742 • 631.207.1200 • FAX: 631.207.0900

Email: [email protected]

www.weissinstruments.com

CAT NO.

HOLTSVILLE, NEW YORK 11742

631-207-1200 • FAX: 631.207.0900

www.weissinstruments.com

XJR40D

Project Name:

Location:

IDN#

Catalog#

4 Zone Lighting Controller

Quanity:

Manage lights on the Internet via the XWEB

The XJR40D is a network module that can manage up to 4 lighting zones. It features four on/off keys and

LED indicators on the front. Each output can be controlled with 4 corresponding digital inputs like a remote switch, occupancy or light sensor for sunrise and sunset operation. In addition the XJR40D is connected to an XWEB LAN and receives on/off signals from the Scheduler Function via the RS485 Serial connection. 24/7/365 control is easily set-up with the XWEB scheduler in order to reduce energy. The unit transfers the data to an XWEB over a RS485 Network.

An optical light sensor can also be added to detect when lights are out and initiate an alarm via the

XWEB to notify the right personnel to replace/repair lights.

The XJP40D can be wall of Din Mounted or placed in a Din Enclosure.

The serial communication enables the XJP40D to connect to XWEB Monitoring Systems and other open systems using ModBus-RTU.

Applications include Control of:

• 4 zones of Lighting

• Sprinkler Systems

• Occupancy/Security

• On/Off of Loads via Schedule

• Detect when Lights are out

Options

– Occupancy Sensor

– Photo Electric Sensor

– Remote on/off

L ight

B ank/

4 Zone Controller

4

APPROVALS:

DATE:

4/09

CAT NO.

XJR40D 4 Zone Lighting Controller

OVERVIEW

The Control shall have four status LED indicators corespondent to it’s four manual key switched in addition to a Power indicator LED. The unit has 4 Digital Inputs

(voltage free open/Closed circuit ) that can control each of the 4 8A relay outputs. It shall have an RS485 Connection.

MOUNTING

The product is 4DIN RAIL or wall mounted in a DinBox and shall have IP65 protection from the front.

SENSOR

The product shall have up to 4 Digital Input sensors such as a photoelectric eye, occupancy sensor or remote on/off or any other open or closed Digital signal.

POWER

The product shall be powered by 120Vac or 230Vac

XJR40D

INPUTS

The control shall have 4 Digital input (open/closed circuit) that is typically used with photoelectric sensors for sunrise/sunset operation or occupancy sensors.

OUTPUTS

The XJR40D has 4 8A SPDT relay outputs.

COMMUNICATIONS

The Control shall have an RS485 Serial port. The two way communication protocol shall be MOD-BUS-RTU. The Module shall have a settable 4 serial address’s from 1 to 247. MOD-BUS Comments, Registers and Hex Codes are free and open, are available on request.

PROGRAMMING

The control is pre-programmed and pre-addressed for 4 zone lighting. There shall be 2 levels of control parameters that are password protected. A Hot

Key flash memory device can upload or download a program to the unit.

The program shall remain in internal memory without power.

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

WARRANTY

ONE YEAR

WEISS INSTRUMENTS, INC., 905 WAVERLY AVE., HOLTSVILLE, NEW YORK 11742 • 631.207.1200 • FAX: 631.207.0900

Email: [email protected]

www.weissinstruments.com

HOLTSVILLE, NEW YORK 11742

631-207-1200 • FAX: 631.207.0900

www.weissinstruments.com

CAT NO.

XR30CX

XR70CX

Project Name:

Location:

IDN#

Catalog#

Refrigeration Controllers

Quanity:

Controls for Medium and Low Temp Applications

The Dixell CX controls for Refrigeration replace the functions of mechanical thermostats, defrost time clocks, fan control and alarms, in a compact unit that displays the temperature and appliance status in an easy to read LED

Display. Fully programmable to meet all Medium and Low temperature applications, the CX Series Controls are

UL and NSF listed and operate with line voltage power(120Vac or 230Vac) and large feature internal relays (16A) to ensure a long and reliable operation.

The serial communication enables the CX controls to connect to XWEB Monitoring Systems and other open systems using ModBus-RTU. Multiple temperature, Digital Inputs and up to four relay outputs allow the CX Controls to meet various refrigeration applications.

OUTPUTS (XR70CX) up to 4

1. Compressors/Solenoid Valve (one or two)

2. Defrosts (electric or hot gas,one or two)

3. Evaporator Fans

4. Alarm or

Lights or

Condenser fans or

Anti-Sweat Heaters

OUTPUTS (XR30CX) up to 2

1. Compressors/Solenoid Valve w/Off Cycle

Defrost

2. Alarm or

Lights

PROBE INPUTS

1. Room (controlling)

2. Evaporator (end defrost/control fans)

3/4. Opt. Display/Condenser/2nd zone

3/09

MODEL RC

APPROVALS:

DATE:

CAT NO.

XR30CX

XR70CX Refrigeration Controllers

OVERVIEW

The product has .5” LED temperature display and up to 8 status Icons on the front display. The unit shall have a 6 keypad interface, consisting of a Up, Down,

SET, DEF, Light and ON/OFF or ES Mode (Energy Savings) The control can display in either °F or °C and have a range of -58°F to 230°F (°C)

MOUNTING

The product is panel mounted in a 29 x 71mm panel hole or wall mounted in a C-Box 108 x 108 x 90mm enclosure.

SENSOR

The product shall have up to 2 NTC Thermistors (XR30CX) or up to 4 (XR70CX) temperature probes, which can be extended up to 300ft. The Room probe

(controlling probe) is to be placed typically in the return–air, or discharge air, and the Evaporator probe to be mounted in the coldest spot of the evaporator.

Optional third and fourth probes can be used for display or condenser.

POWER

The product shall be powered by 120Vac or 230Vac (+/-10% 50/60Hz).

INPUTS

The CX control shall have one Digital Input (open/closed circuit) that is typically used with a magnetic door switch to indicate door openings.

OUTPUTS

The XR30CX has two relay outputs. Compressor (or solenoid valve) rated at

16FLA/96LRA plus a second relay (8A) for alarm, light or fan.

The XR70CX has four relay outputs. Compressor 16FLA/60LRA, Defrost 8A,

Fan 5A, plus a fourth 8A relay, that can be configured as: Alarm/Light/2nd

Comp/2nd Def/Anti-Sweat heater.

COMMUNICATIONS

The Product has a TTL Serial port. A XJ485CX adaptor is required. The two way communication protocol is MOD-BUS-RTU. The Control has a settable serial address of 1-247. MOD-BUS–Comments, Registers and Hex Codes are free and open (available on request.)

PROGRAMMING

The control is pre-programmed for Medium temp applications (XR30CX), and

Low Temp applications (XR70CX). There are 2 levels of parameters that are password protected. The Keyboard can also be locked. A Hot Key flash memory device can upload or download a program to the unit. The program shall remain in internal memory without power.

XR30CX

XR70CX

Dimensions in mm.

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

WARRANTY

ONE YEAR

WEISS INSTRUMENTS, INC., 905 WAVERLY AVE., HOLTSVILLE, NEW YORK 11742 • 631.207.1200 • FAX: 631.207.0900

Email: [email protected]

www.weissinstruments.com

advertisement

Key Features

  • Web based monitoring & control
  • Records temperature, status, and alarm data
  • Manages and optimizes appliances
  • Supports up to 247 control & monitoring devices
  • RS485 network with wireless option
  • Secure access via standard browser
  • Supports multiple probe inputs
  • Provides digital inputs & relay outputs
  • Easy to program and configure

Related manuals

Frequently Answers and Questions

What are the main applications of the XWEB gateway?
The XWEB gateway is primarily used for monitoring and controlling commercial appliances in food service, restaurants, C-stores, warehouses, supermarkets, and retail environments. It can be used to monitor and manage refrigeration, walk-ins, food warming/ovens, HVAC, lighting, and energy monitoring.
How many control and/or monitoring devices can be connected to the XWEB gateway?
The XWEB gateway can support up to 247 control and/or monitoring devices.
What kind of network connection does the XWEB gateway use?
The XWEB gateway uses a two-wire RS485 network, which can be up to 1 mile long. Optional wireless network connections are also supported.
How is the XWEB gateway programmed?
The XWEB gateway is pre-programmed for various applications. You can access and modify the parameters using a standard browser interface, and there are two levels of password protection for security.
What is the purpose of the XJP60D module?
The XJP60D module is designed for monitoring temperatures, pressure, humidity, and other inputs from up to 6 probes. It's ideal for monitoring walk-in coolers and freezers, reach-ins, food warming cabinets, A/C and outdoor temps, pressure, humidity, level, or flow.
What types of digital inputs and relay outputs does the XJR40D module offer?
The XJR40D module has 4 digital inputs, which can be used with sensors like photoelectric sensors for sunrise/sunset operation, occupancy sensors, or remote on/off switches. It also has 4 relay outputs that can control lighting, sprinkler systems, occupancy/security, and on/off of loads via schedule.
What are the key features of the XR30CX and XR70CX refrigeration controllers?
The XR30CX and XR70CX refrigeration controllers are compact units that replace mechanical thermostats, defrost time clocks, fan control, and alarms. They feature an LED display for temperature and appliance status, are fully programmable for medium and low temperature applications, and use line voltage power (120Vac or 230Vac) with large internal relays (16A) for reliable operation.