The Spa Industries TP400 is a hot tub that features two independent temperature settings, allowing you to set a 'ready to use' temperature and a 'vacation' temperature. The TP400 also has a 'Hold' mode that allows you to disable the pumps for cleaning or filter replacement. With programmable filter cycles, you can ensure the water is clean and fresh, while the 'Ready' mode circulates water every 30 minutes to maintain a constant water temperature. The TP400 also has a range of safety features, such as a lock function that prevents unauthorized use.

advertisement

Spa Industries TP400 Quick Reference Guide | Manualzz

TP400 Quick Reference Guide

TP400

Start up

When the spa is switched on, a start up sequence of numbers will appear on the display. If no button is pressed, LINK will appear after the start up sequence. Press any button to link the panel with the system.

The spa will enter Priming Mode. After Linking, press the Jets Button(s) to turn the pumps on and off to verify that all air is purged from the plumbing, particularly the plumbing associated with the heater. If the spa has an Eco Filtration Pump, the light Button turns the Circ Pump on and off during Priming Mode. Priming Mode will end automatically in 4 minutes. Pressing Temperature Button Down t will exit Priming Mode manually. When Priming Mode ends, Pump1 low will start if no Circ Pump is present, however the water temperature will not appear for a minute or so. Once the water temperature is recognized by the system, and if it is below the Set Temperature, the heater will start.

Default Pre-Set

The default preset temperature is 38C in Ready Mode. The Filter Cycles are 8:00 to 12:00 and 20:00 to 0:00

Temperature Adjustment

TP600 touch pad has the Up ▲ and Down t buttons as Temperature Buttons. While TP400 only has a single Temperature Button.

Press the Temperature Button once and the current Set Temperature will begin to flash on the LCD. (The Set Temperature and the actual water temperature are often different.) While the numbers are flashing, press the Temperature Button again to change the

Set Temperature. Press-and-hold for faster adjustment. After the new Set Temperature stops flashing, in about 10 seconds, the actual temperature is displayed again and the new Set Temperature is programmed. The spa will now heat to the new Set Temperature as needed.

Set the Time-of-day

Press , then press repeatedly until ‘TIME’ appears in the LCD. Press

to select the minute and then press to set the minute. Press

to select the hour and press to set. Press

or wait for 10 seconds to go back to the Main Screen.

Dual Temperature Ranges (High Vs Low)

This system incorporates two temperature range settings with independent set temperatures. The High Range is indicated in the display

Range up ▲. The Low Range is indicated in the display Range down t.

To change the Temperature Range, press for 10 seconds to go back to the Main Screen.

then , and press to toggle the Range arrows in the LCD. Press or wait

These ranges can be used for various reasons, with a common use being a ‘ready to use’ setting Vs a ‘vacation’ setting. Each range maintains its own set temperature as set by the user. This way, when a range is chosen, the spa will heat to the set temperature associated with that range.

High Range can be set between 26.5°C to 40°C.

Low Range can be set between 10°C to 36°C.

Setting Ready and Rest Mode

READY mode will circulate water every 30 minutes in order to maintain a constant water temperature, heat as needed, and refresh the temperature display.

‘the name behind the big brands’

TP400 Quick Reference Guide

REST mode will only allow heating during programmed filter cycles. Since polling does not occur, the temperature display may not show a current temperature until the heater pump has been running for a minute or two.

Press , then press repeatedly until ‘MODE’ appears in the LCD. Toggle between READY and REST by pressing

or wait for 10 seconds to go back to the Main Screen.

. Press

Flip (Invert Display)

TP600 has a dedicated FLIP button, which allows the user to flip the display with a single button-press.

TP400 has no FLIP button. To get the display flipped, press to toggle the inversion of the segmented characters. Press

, then press repeatedly until ‘FLIP’ appears in the LCD. Press

to go back to the main screen.

Lock

The control can be restricted to prevent unwanted use or temperature adjustments. Locking the Panel prevents the controller from being used, but all automatic functions are still active. Locking the Temperature allows jets and other features to be used, but the Set temperature and other programmed settings cannot be adjusted.

Lock the Temperature

Press , then press repeatedly until ‘LOCK’ appears in the LCD. Press 3 times, then press

Lock Panel

Press , then press repeatedly until ‘LOCK’ appears in the LCD. Press ,

Unlock the Temperature and the Panel

Press and hold button and press twice. The panel will be unlocked after 3 seconds.

, , ,

.

.

Hold

Hold Mode is used to disable the pumps during functions like cleaning or replacing filters. Hold Mode will last for 1 hour unless the mode is exited manually. If the spa service requires more than an hour, it is best to simply turn the spa off at the main power supply.

Press , then press repeatedly until ‘HOLD’ appears in the LCD. Press . To terminate the ‘HOLD’, press twice.

Setting Filter Cycles

The system is factory-programmed with two filter cycles that will run in the evening and morning. The filter time and duration are programmable. The second filter cycles can be disabled as needed.

Press flash. Press

Press the

, then press repeatedly until ‘FLTR 1’ appears in the LCD. Press

repeatedly to set the hour. Then press

then

twice, the start time will show and the hour will

, the ‘FLTR 1’ length in hours will show and the hour will flash. Press

to select the minutes. Press to set the minutes.

to select the minutes. Press to set the minutes.

repeatedly to set the hour. Then press

Press 3 times, the ‘FLTR 2’ will appears in the LCD. Press , then , the start time will show and the hour will flash.

Press

Press the

repeatedly to set the hour. Then press

then

to select the minutes. Press

to select the minutes. Press

to set the minutes.

to set the minutes.

, the ‘FLTR 2’ length in hours will show and the hour will flash. Press repeatedly to set the hour. Then press

Wait for 30 seconds to go back to the Main Screen.

Preferences

Set between °F and °C. Press or °C.

then press until F/C appears. Press and select the mode of temperature you require °F

6 – 16 Keppel Drive, Hallam Victoria 3803 Australia Ph: 61 3 9702 3144

advertisement

Key Features

  • Dual temperature ranges
  • Programmable filter cycles
  • Ready mode
  • Hold mode
  • Lock function

Related manuals

Frequently Answers and Questions

What are the different temperature ranges I can use?
There are two temperature ranges: High and Low. The High Range can be set between 26.5°C to 40°C, and the Low Range can be set between 10°C to 36°C.
How do I program the filter cycles on my TP400 spa?
You can program the start time and duration of two filter cycles. The second filter cycle can be disabled if needed.
What is the difference between Ready and Rest mode?
Ready mode circulates water every 30 minutes to maintain a constant temperature and refresh the display, while Rest mode only allows heating during programmed filter cycles.