Maytag Services
Training Bulletin
Product: New Electronic Control Date: August 1, 2005
IntelliDial Electronic Laundry Controls
A new line of electronic controls, “IntelliDial”, hits the Sales Floor in August. The new controls will be used on Maytag high end top load washers and gas and electric dryers. The new control system uses a solid state timer and encoder (logic) switches in place of the electro-mechanical timer and switches used in the past. The IntelliDial electronic timer control rotates in either direction without the need to pull out or push in the CSK (Cycle Selection Knob). LED indicator lights around the
CSK illuminate as the knob is turned to indicate the cycle choices. A row of LED lights under the
CSK illuminate to show the status of the machine as it progresses through the cycle.
One washer and one dryer control circuit board is used for all models. These circuit boards are loaded at the time of manufacture with the software needed to support a variety of product models. A control membrane specific to each model determines which portion of the preloaded software is used. A primary encoder switch connects the model specific membrane to the control circuit board. A conventional two position water level pressure switch is used to determine water level.
Primary Encoder Switch
(behind CSK)
CSK – Cycle Selector Knob
Infinite Water Level
Mini
Small
Medium
Large
Super reset
Extra Rinse
Off On
Cold
Cold
Wash/Rinse Temp
Autom atic Tem perature Control
A.T.C.
Cold
Cold
A.T.C.
Warm
Cold
A.T.C.
Hot
Cold
Light
Soil Selec tion
Normal Heavy
Extra Heavy
Fabric Selec tion
Handwash
Ex. Gentle/Slow
Delic ates
Gentle/Slow
Quic k Wash
Gentle/Fast
Perm Press
Medium/Slow
Regular
Medium/Fast
Signal
On
Control membrane
Off is part of fascia
Cycle Status
Push to Start - Push to Stop
Cycle Status Lights (7)
Water Level /Pressure Switch Encoder Switches
Note: Always refer to the Technical Data Sheet shipped with the product for detailed service information for the model you are servicing
Page 1
Accessing Controls
To access the control components begin by removing three screws across the top of the control console
The control console can be rolled out and down for front serviceability
Remove the hose to the pressure switch to ease positioning of the console
Page 2
Component Identification
Rotary encoder switches are used for option selection
A primary encoder is used for cycle selection
A convention pressure switch is used to control water level
Caution: Always be static aware when handling electronic control circuit boards. Make sure to discharge any static charge you may be carrying to ground
To remove the control board:
Remove the cycle selector knob; be careful not to damage the encoder or fascia when removing
Use a small diameter wire looped under the cycle selector knob to remove
Page 3
Remove the five edge connectors attached to the control circuit board
Unplug the red and white wire connectors from the board. When installing make sure to follow the color code printed on the control board
Page 4
Depress the two locks and lift out the control circuit board. Make sure to insert the board into the slots provided in the console when installing the board
Depress the two locks
Lift out the board
Depress the two locks securing the
Control board to the console
To remove any encoder or the pressure switch
Lift out the board
Primary
Encoder
Options
Encoder
The encoders can be easily identified – The primary encoder used with the control circuit board has the short ribbon connector. Option encoders are labeled P2, P3, P4 or P5 to correspond with the selections available.
Page 5
The machine control circuit board is equipped with diagnostic software to aid in troubleshooting.
The first step to access any test is to enter the Service Mode
Entering the “Service Mode”
Rotate the Cycle Selector Knob (CSK) to the
“Power Off” position and press
(All LED’s will be off).
Note: If the machine is in operation, you must press the CSK to first pause the unit
(Pause light illuminates) and then rotate the knob to the Power Off position and press
Rotate the Cycle Selector Knob clockwise past
“Power Off” twice and stop at “Regular”. LED’s will illuminate as the knob is rotated.
(If the knob is inadvertently turned past “Regular” the control will not go into the Service Mode and the procedure must be started from the beginning.)
Page 6
Exit Service Mode
Rotate the Cycle Selector Knob counterclockwise one revolution back to “Regular” and press.
The Power Off LED will begin blinking.
Status lights will illuminate indicating the model I.D.
The Rinse& Spin LED will blink if there are service codes stored in the memory other
. than a power interruption
The Regular LED will illuminate
(Note: If the knob is inadvertently turned past
“Regular” the control will not go into the Service
Mode and the procedure must be started from the beginning.)
Rotate the Cycle Selector Knob to
Power Off and press
Or,
Allow 10 minutes for auto exit after last switch movement.
Or,
Disconnect Power to the washer.
Note: The above actions terminate
Service mode but not the advertising mode
Display Model ID
A sequence of illuminated cycle status LED’s below the CSK is used to determine the Model
ID of the product. A chart (included with this information) must be used to interpret the light pattern. The Model ID indicator light pattern is always displayed when the Service Mode is first entered. Once in the Service Mode. Rotate the Cycle Selector Knob to Hand wash and press to access this feature.
Page 7
Model ID Chart – The chart below is used to determine the Model ID from the sequence of
Status LED’s illuminated. The model ID must match the machine you are servicing.
Washer Model
Number
Binary
Code
0 4 2 1 4
Fill Soak Wash Rinse Spin Complete Pause
MAV546E 43
MAV5920AGW (INT) 44
MAV508DE,
MAV551E
MAV5757, MAV5858
45
46
2 1
MAV5920E 47
NAV8805 53
Illuminated Status Lights under CSK Indicate Binary
Code
Display/Clear Service Codes
Enter Service Mode then set Rotary
Cycle Selection Knob to “Rinse & Spin”.
Press knob
• Tap CSK to view all codes. Codes are displayed newest to oldest. Machine beeps three times after last service code is displayed.
• To clear codes press and hold Rotary
Cycle Selection Knob until machine beeps twice. Rinse & Spin LED stops blinking.
(Switch must be depressed approximately
5 seconds)
• Refer to chart for Service Codes.
Service Code Chart
Error Discription
64
Binary Code Fill
Model ID unknown,
Default to model 31
Switch 3, left of the encoder, failed to read a valid value at startup
Switch 2, left of the encoder, failed to read a valid value at startup
Switch 1, left of the encoder, failed to read a valid value at startup
31
28
26
25
Incorrect rotary switch position detected 24
32
Soak
16 8
Wash Rinse
4
Spin
2
Complete
1
Pause
Fill time less than 2 seconds 22
Fill time exceeds 18 minutes
Motor Thermal protector open
Motor Thermal protector opened more than 5 times
Thermistor possibly shorted
Thermistor possibly open
Thermistor value out of range
Power Failure detected
No Codes
1
0
16
15
21
19
18
17
Match the status light pattern to the error discription
Page 8
Console Switch Test
Enter Service Mode then set Cycle Selection
Knob to “Delicate” and press knob.
• Power Off LED blinks.
• Pause and Delicates LED’s are illuminated.
There are 32 detent positions in one complete revolution of the primary encoder
.
Rotate the
Cycle Selection Knob clockwise or counterclockwise to check.
Note: The status lights under the CSK will illuminate in a specific pattern as the CSK is rotated.
Press the Cycle Selection Knob to activate the test for the rotary switches. The test begins with the rotary switch imediately to the left of the Cycle Selection Knob. Rotate the switch in either direction. The LED’s illuminate around the bottom of the Cycle Selection Knob for each switch position.
NOTE: Any attempt to move a knob or switch other than the one being tested results in a chirp sound.
Page 9
Service Cycle Test
X
Press the Cycle Selection Knob. The test continues with the switch immediately to the left of the previous switch tested. Repeat rotating the switch and monitoring the LED’s around the bottom of the Cycle Selection Knob.
Continue pressing the Cycle Selection Knob for each switch tested right to left untill all rotary switches are tested.
NOTE: The Water Level Switch is not included in this test.
• After the last rotary switch is tested the next time the Cycle Selection Knob is pressed the test will continue with the rocker switches. Continue pressing the Cycle
Selection Knob and testing switches until the last switch is tested. When all switche have been tested the “Complete” LED will illuminate.
Once in the Service Mode,
Rotate the CSK to Regular and press to enter the washer service cycle:
Hot water fill valve will Fill & Wash LEDS illuminate energize.
Tap CSK–Cold water valve Fill& Rinse LEDS illuminate will energize
Tap CSK–Selected wash Fill& Wash & Rinse temperature fill
Tap CSK– Agitate slow
Tap CSK – Agitate Fast
Tap CSK – Spin Slow
( there will be a slight delay until motor stops)
Tap CSK – Spin Fast
Tap CSK – Cycle Complete
Tap CSK – Exit to Service
LEDS illuminate
Wash LED illuminates
Wash LED blinking
Spin LED illuminates
Spin LED blinking
Complete LED illuminates
Mode
(Note: Press CSK until
Pause LED begins blinking to pause the Service Cycle
Test)
advertisement