advertisement
Product data sheet
CONTACTOR, AC-3 3 KW/400 V, 1 NO,
AC 230 V, 50/60 HZ, 3-POLE, SIZE S00,
SCREW CONNECTION
3RT1015-1AP01
General technical data:
product brand name
Size of the contactor
Protection class IP / on the front
Degree of pollution
Installation altitude / at a height over sea level / maximum
Ambient temperature / during operating
Mechanical operating cycles as operating time
• of the contactor / typical
• of the contactor with added auxiliary switch block / typical
• of the contactor with added electronics-compatible auxiliary switch block / typical
Main circuit:
Number of NC contacts / for main contacts
Number of NO contacts / for main contacts
Operating current
• at AC-1 / at 400 V
• at 40 °C ambient temperature / rated value
• at AC-3 / at 400 V / rated value
• at AC-4 / at 400 V / rated value m
°C
SIRIUS
S00
IP20
3
2,000
-25 … +60
30,000,000
10,000,000
5,000,000
0
3
A
A
A
18
7
6.5
3RT1015-1AP01
Page 1/ 5 07/14/2014 subject to modifications
© Copyright Siemens AG 2014
• with 1 current path / at DC-1
• at 24 V / rated value
• at 110 V / rated value
• with 2 current paths in series / at DC-1
• at 24 V / rated value
• at 110 V / rated value
• with 3 current paths in series / at DC-1
• at 24 V / rated value
• at 110 V / rated value
• with 1 current path / at DC-3 / at DC-5
• at 24 V / rated value
• at 110 V / rated value
• with 2 current paths in series / at DC-3 / at DC-5
• at 24 V / rated value
• at 110 V / rated value
• with 3 current paths in series / at DC-3 / at DC-5
• at 24 V / rated value
• at 110 V / rated value
Service power
• at AC-2 / at 400 V / rated value
• at AC-3 / at 400 V / rated value
• at AC-4 / at 400 V / rated value
Control circuit:
Voltage type / of control feed voltage
Operating range factor control supply voltage rated value / of the magnet coil
• at 50 Hz
• for AC
• at 60 Hz
• for AC
Apparent pull-in power / of the solenoid / for AC
Apparent holding power / of the solenoid / for AC
Inductive power factor / with the pull-in power of the coil
Inductive power factor / with the pull-in power of the coil
Auxiliary circuit:
Contact reliability / of the auxiliary contacts
Number of NC contacts / for auxiliary contacts / instantaneous switching
Number of NO contacts / for auxiliary contacts / instantaneous switching
A
A
A
A
A
A
A
A
A
A
A
A kW kW
W
3
3
3,000
15
0.25
15
15
15
15
15
0.1
15
1.5
15
8.4
AC
0.8 … 1.1
V·A
V·A
0.85 … 1.1
27
4.4
0.8
0.27
1 faulty switching per 100 million (17 V, 1 mA)
0
1
3RT1015-1AP01
Page 2/ 5 07/14/2014 subject to modifications
© Copyright Siemens AG 2014
Short-circuit:
Design of the fuse link
• for short-circuit protection of the auxiliary switch / required
• for short-circuit protection of the main circuit
• with type of assignment 1 / required
• at type of coordination 2 / required
Installation/mounting/dimensions:
Mounting type series installation
Width
Height
Depth
Distance, to be maintained, to earthed part / sidewards
Connection type:
Design of the electrical connection
• for main current circuit
• for auxiliary and control current circuit
Type of the connectable conductor cross-section
• for main contacts
• solid
• finely stranded
• with conductor end processing
• for AWG conductors / for main contacts
• for auxiliary contacts
• solid
• finely stranded
• with conductor end processing
• for AWG conductors / for auxiliary contacts
Certificates/approvals:
fuse gL/gG: 10 A fuse gL/gG: 35 A fuse gL/gG: 20 A mm mm mm mm screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Yes
45
57.5
72
6 screw-type terminals screw-type terminals
2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x
(0.75 ... 4 mm²)
2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
2x (20 ... 16), 2x (18 ... 14), 1x 12
2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x
(0.75 ... 4 mm²)
2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
2x (20 ... 16), 2x (18 ... 14), 1x 12
3RT1015-1AP01
Page 3/ 5 07/14/2014 subject to modifications
© Copyright Siemens AG 2014
General Product Approval
Declaration of
Conformity
Test Certificates
Special Test
Certificate
Shipping Approval
Shipping Approval other
Confirmation other Environmental
Confirmations
Further information:
Information- and Downloadcenter (Catalogs, Brochures,…) http://www.siemens.com/industrial-controls/catalogs
Industry Mall (Online ordering system) http://www.siemens.com/industrial-controls/mall
Cax online generator: http://www.siemens.com/cax
Service&Support (Manuals, Certificates, Characteristics, FAQs,...) http://support.automation.siemens.com/WW/view/en/3RT1015-1AP01/all
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...) http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3RT1015-1AP01
Functional Safety /
Safety of
Machinery
Type Examination
3RT1015-1AP01
Page 4/ 5 07/14/2014 subject to modifications
© Copyright Siemens AG 2014
last change: Jul 7, 2014
3RT1015-1AP01
Page 5/ 5 07/14/2014 subject to modifications
© Copyright Siemens AG 2014
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project