Data communications module (D4-DCM)

Data communications module (D4-DCM)
Prices as of April 27, 2016. Check Web site for most current prices.
Serial Data Communications Module
Data
Communications
Module
D4-DCM $357.00
Overview
Extra communications
port
All DL405 CPUs offer at least two built-in
communication ports. (The D4-450 even
has four ports.) However, if even more
communication ports are needed, additional Data Communication Modules can
be added. As an extra communication
port, the DCM has specifications identical
to port 1 on the DL405 CPUs. Whatever
can be connected to port 1 of the DL405
CPU can be connected to the DCM,
just make sure the device has a DL405
compatible driver. This allows additional
connections of devices, such as operator
interfaces, personal computers, etc. Since
the DCM does not require any programming, you can set the DCM communication parameters, connect the cables, and
start transferring data.
The DL405 Data Communication Module
(DCM) is a general purpose communications interface for the DL405 family of
PLCs. This module is primarily used for
three reasons:
• Extra general purpose communications port
to connect a personal computer, operator
interface, etc.
• Network interface to a DirectNET network
• Network interface to a Modbus network using
the RTU protocol as slave.
Online/
Offline
Switch
Address
Selection
Switch
DIP Switches for communications
and Protocol Setup
Specifications
Module Type
Modules per CPU
Intelligent
Communications
RS232C/422, DirectNET, SIMATIC®TI405™, or Modbus (slave only) RTU protocol.
Baud rate selectable from 300 to 38.4K baud. Odd or no parity. HEX or ASCII mode
Recommended Cable
Belden 9729 or equivalent (for RS422)
Field Wiring Connector
Internal Power
Consumption
Operating Environment
25 Pin D-shell connector
Manufacturer
Koyo Electronics
7 Maximum, any slot in CPU Base
500mA maximum at 5VDC, (supplied by base power supply)
0°C to 60°C (32°F to 140°F), 5% to 95% humidity (non-condensing)
DCM as auxiliary port
Connect the DCM to our
MDM-TEL serial modem. See
the Communication Products
section of this catalog for
details on the modem.
RS232C/RS422
Communication Port
Book 1 (14.3)
eD4-28
DL405 PLCs
1-800-633-0405
Prices as of April 27, 2016. Check Web site for most current prices.
Serial Data Communications Module
DirectNET network
interface
The DCM can be used as a network
interface for applications requiring data
to be shared between PLCs, or between
PLCs and an intelligent device such as a
host computer. The DCM connects easily
to DirectNET. This network allows you to
upload or download virtually any type of
system data including timer/counter data,
I/O information, and V-memory information from any of our PLCs or compatible
PLC. The DCM allows the DL405 PLC
to function as a master or a slave of
DirectNET.
Control Systems
Overview
CLICK PLC
Master/slave Network
DL405
DCM as master
Do-More
PLCs Overview
Do-More H2
PLC
Do-More T1H
PLC
DirectLOGIC
PLCs Overview
DCM slave
D2-260 slave
DirectLOGIC
DL05/06
DirectLOGIC
DL105
DL405 CPU
(bottom port)
D3-350 slave
Peer network
Network Master - The DCM allows the
DL405 to serve as a master of a DirectNET
Network. The DCM takes communication
requests issued from the PLC program
(the network part of the program can be
very simple, as few as seven words) and
automatically converts these requests into
network commands to read data from or
write data to another PLC on the network.
This capability also allows a peer to peer
configuration of two DL405 systems with
DCMs. For other options, consider the
H4-ECOM100 module.
Network Slave - All DL405 CPUs have
a built-in network slave port. If this port
is occupied, a DCM can be added to
provide an additional network slave
port. In this case, the DCM “listens” to
the network for any messages containing
the DCM’s address. The DCM deciphers
the network commands, carries out the
request to read or write data, and sends
confirmation and/or information to the
master station. Since the DCM does not
require any programming, you can set
the DCM communication parameters,
connect the cables and start transferring
data.
Company
Information
DirectLOGIC
DL205
DirectLOGIC
DL305
DirectLOGIC
DL405
Productivity
Controller
Overview
Productivity
3000
DCM as master
DCM as slave
Universal
Field I/O
Software
Modbus master
C-More
HMI
Modbus network using
RTU protocol
C-More Micro
HMI
ViewMarq
Industrial
Marquees
Other HMI
Communications
In a slave station...
responds to network requests
Appendix
Book 1
Terms and
Conditions
DL405 slave with DCM
Modbus interface
The DCM can be used as a slave
station interface to connect your DL405
system to the Modbus network using the
Modbus RTU protocol. The host system
must be capable of issuing the Modbus
commands to read or write the appropriate data.
Book 1 (14.3)
www.automationdirect.com/dl405
DL405 PLCs
eD4-29
Prices as of April 27, 2016. Check Web site for most current prices.
Check the Power Budget
Verify your power budget
requirements
This logo is placed next to I/O modules
that are supported by the ZIPLink connection systems.
Your I/O configuration choice can be
affected by the power requirements of the
I/O modules you choose. When determining the types and quantity of I/O
modules you will be using, it is important
to remember there is a limited amount of
power available from the power supply.
See the I/O module specifications at the
end of this section.
The chart on the opposite page indicates
the power supplied and used by each
DL405 device. The adjacent chart shows
an example of how to calculate the power
used by your particular system. These
two charts should make it easy for you to
determine if the devices you have chosen
fit within the power budget of your system
configuration.
Calculating your power
usage
The following example shows how to
calculate the power budget for the DL405
system. The example is constructed around
a single 8-slot base using the devices
shown. It is recommended you construct a
similar table for each base in your system.
A
Base Number
0
Device Type
B
5 VDC (mA)
External 24 VDC
Power (mA)
CURRENT SUPPLIED
CPU/Expansion Unit
/Remote Slave
D4-440 CPU
C
3700
400
CURRENT REQUIRED
If the I/O you have chosen exceeds the
maximum power available from the power
supply, you can resolve the problem by
shifting some of the modules to an expansion base or remote I/O base (if you are
using remote I/O).
SLOT 0
D4-16ND2
+150
+0
SLOT 1
D4-16ND2
+150
+0
SLOT 2
F4-04DA
+120
+100
SLOT 3
D4-08ND3S
+100
+0
D4-08ND3S
+100
+0
Warning: It is extremely important to calculate the
power budget correctly. If you exceed the power
budget, the system may operate in an unpredictable
manner which may result in a risk of personal injury
or equipment damage.
SLOT 4
SLOT 5
D4-16TD2
+100
+0
SLOT 6
D4-16TD2
+100
+0
SLOT 7
D4-16TR
+1000
+0
BASE
D4-08B
+80
+0
Handheld Programmer
D4-HPP
+320
+0
E Maximum Current Required
2820
100
F Remaining Current Available
3700-2820=880
400-100=300
D
Use ZIPLinks to reduce
power requirements
If your application requires a lot of relay
outputs, consider using the ZipLink AC
or DC relay output modules. These
modules can switch high current (10A)
loads without putting a load on your base
power budget. Refer to Wiring System for
DL405 PLCs later in this section for more
information.
OTHER
1. Using a chart similar to the 3one above, fill in column 2.
2. Using the tables on the opposite page, enter the current supplied and used by each device (columns 3 and 4). Pay special attention to
the current supplied by the CPU, Expansion Unit, and Remote Slave since they differ. Devices which fall into the “Other” category (Row D)
are devices such as the Base and the Handheld programmer, which also have power requirements, but do not plug directly into the base.
3. Add the current used by the system devices (columns 3 and 4) starting with Slot 0 and put the total in the row labeled “maximum current required” (Row E).
4. Subtract the row labeled “Maximum current required” (Row E), from the row labeled “Current Supplied” (Row B). Place the difference in
the row labeled “Remaining Current Available” (Row F).
5. If “Maximum Current Required” is greater than “Current Supplied” in either column 3 or 4, the power budget will be exceeded. It will be
unsafe to use this configuration and you will need to restructure your I/O configuration. Note the auxiliary 24 VDC power supply does not
need to supply all the external power. If you need more than the 400mA supplied, you can add an external 24VDC power supply. This will
help keep you within your power budget for external power.
DL405 CPU power supply specifications and power requirements
Specification
Part Numbers
AC Powered Units
D4-450, D4-440, D4-430,
D4-EX (expansion base unit),
D4-RS (remote slave unit)
Voltage Withstand (dielectric)
24 VDC Powered Units
D4-450DC-1, D4-440DC-1,
D4-EXDC (expansion base unit),
D4-RSDC (remote slave unit)
125 VDC Powered Units
D4-450DC-2
D4-440DC-2
1 minute @ 1,500 VAC between primary, secondary, field ground, and run relay
Insulation Resistance
> 10Mq at 500VDC
Input Voltage Range
85-132 VAC (110 range) 170-264 VAC (220
range
20-28 VDC (24 VDC)
with less than 10% ripple
90-146 VDC (125 VDC)
with less than 10% ripple
Maximum Inrush Current
20 A
20 A
20 A
Maximum Power
50 VA
38 W
30 W
Book 1 (14.3)
eD4-24
DL405 PLCs
1-800-633-0405
Prices as of April 27, 2016. Check Web site for most current prices.
Power Requirements
Company
Information
Control Systems
Overview
CLICK PLC
Power Supplied
CPUs/Remote Units/
Expansion Units
5 VDC Current
Supplied in mA
24V Aux Power
Supplied in mA
CPUs/Remote Units/
Expansion Units
5V Current Supplied
in mA
24V Aux Power
Supplied in mA
D4-430 CPU
D4-440 CPU
D4-440DC-1 CPU
D4-440DC-2 CPU
D4-450 CPU
D4-450DC-1 CPU
D4-450DC-2 CPU
3700
3700
3700
3700
3100
3100
3100
400
400
NONE
NONE
400
NONE
NONE
D4-EX
D4-EXDC
D4-EXDC-2
D4-RS
D4-RSDC
H4-EBC
H4-EBC-F
4000
4000
3700
3700
3700
3470
3300
400
NONE
NONE
400
NONE
400
400
Do-More H2
PLC
Do-More T1H
PLC
DirectLOGIC
PLCs Overview
Power Consumed
Power-consuming
Device
I/O Bases
5V Current
Consumed
D4-04B-1
D4-06B-1
D4-08B-1
80
80
80
External 24VDC
Current Required
NONE
NONE
NONE
DC Input Modules
D4-08ND3S
D4-16ND2
D4-16ND2F
D4-32ND3-1
D4-32ND3-2
D4-64ND2
100
150
150
150
150
300 max.
NONE
NONE
NONE
NONE
NONE
NONE
100
150
NONE
NONE
150
90
NONE
NONE
Power-consuming
5V Current
Device
Consumed
Analog Modules (continued)
External 24VDC
Current Required
F4-16AD-1
F4-16AD-2
F4-04DA-1
F4-04DA-2
F4-04DAS-1
F4-04DAS-2
F4-08DA-1
F4-08DA-2
F4-16DA-1
F4-16DA-2
F4-08RTD
F4-08THM-n
F4-08THM
100
100
75+20per circuit
90
60 per circuit
60 per circuit
100+20 per circuit
150
100+20 per circuit
25 max.
NONE
50
60
75
75
70
90
60
60
90
80
90
80
80
120
110
Remote I/O
H4-ERM(100)
H4-ERM-F
D4-RM
DC Output Modules
320(300)
450
300
D4-08TD1
F4-08TD1S
D4-16TD1
D4-16TD2
D4-32TD1
D4-32TD1-1
D4-32TD2
D4-64TD1
150
295
200
400
250
250
350
800
35
NONE
125
NONE
140
140 (15V)
120 (4A max
including loads)
NONE
250
450
NONE
NONE
Relay Output Modules
300
670
500
235
NONE
NONE
NONE
NONE
NONE
65
D4-08TR
F4-08TRS-1
F4-08TRS
D4-16TR
550
575
575
1000
NONE
NONE
NONE
NONE
Analog Modules
Other HMI
Communications
305
Appendix
Book 1
NONE
F4-04AD
F4-04ADS
F4-08AD
Terms and
Conditions
400
100
300
160
225
150
280
NONE
NONE
NONE
NONE
170
NONE
75
320
NONE
DV-1000
150
NONE
C-more Micro-Graphic
210
NONE
Programming
D4-HPP-1 (Handheld Prog.)
150
370
75
100
120
90
Operator Interface
Book 1 (14.3)
www.automationdirect.com/dl405
Productivity
3000
ViewMarq
Industrial
Marquees
Specialty Modules
H4-CTRIO
D4-INT
D4-HSC
F4-16PID
F4-8MPI
D4-16SIM
F4-4LTC
Productivity
Controller
Overview
C-More Micro
HMI
AC Output Modules
D4-08TA
D4-16TA
DirectLOGIC
DL405
C-More
HMI
CoProcessors
F4-CP128-1
DirectLOGIC
DL305
Software
NONE
NONE
NONE
Communications and Networking
H4-ECOM100
H4-ECOM-F
D4-DCM
F4-MAS-MB
FA-UNICON
DirectLOGIC
DL205
Universal
Field I/O
AC/DC Input Modules
D4-16NE3
F4-08NE3S
DirectLOGIC
DL05/06
DirectLOGIC
DL105
AC Input Modules
D4-08NA
D4-16NA
Do-More
PLCs Overview
DL405 PLCs
eD4-25
Was this manual useful for you? yes no
Thank you for your participation!