Pressure Prevention

Pressure Prevention
80" (L) x 36" (W) x 10" (H), Pump and Mattress System, 1/ea
14029DP
HCPCS code:
E0277
FEATURES:
■
This bariatric system provides alternating pressure to optimize
pressure redistribution for patients with up to Stage IV pressure
ulcers in the home, long term care, or acute care setting.
■
10" deep static perimeter tubing surrounds the length of the
mattress preventing the patient from becoming
trapped between the mattress and side rails.
■
Cell-on-cell design of 8" deep air cells prevents
“bottoming out” and also provides up to 24 hours
of power outage protection.
■
Digital pump allows for customization to individual patients’
comfort and safety needs, and will auto-return to alternating
pressure mode if system is left on static mode for >2 hours.
■
4-way stretch cover is low sheer, fluid-resistant,
vapor permeable, quilted and zippered.
■
Each one of the 20, 8" deep air bladders are easily
removed and replaced.
■
Pillow function maintains the 3 air cells at the head
of the bed in static mode for patient comfort.
■
3 diagnostic alarms tell you whether a problem is with
the mattress or the pump for more efficient servicing.
■
450 lb. weight capacity.
CPR valve allows for rapid deflation.
Mattress:
14029DPM
■
SPECIFICATIONS:
Pump:
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
Power: 120 VAC, 60 Hz
Pressure Range: 20 mmHg to 60 mmHg
(inner mattress pressure)
Auto firm (60 mmHg, Auto return in 30 min.)
Seat function (Pressure preset + 10 mmHg)
Static selectable with auto-return to alternating mode.
Adjustable cycle time 10, 15, 20, 25 minutes.
Function lock (Auto lock in 30 seconds)
Low pressure alarm
System (alternating) alarm
Power failure alarm
Alarm mute
Memory function
Air Flow: 8-LPM
Power Cord Length: 15 Ft.
Pump Dimensions: 14.2" (W) x 9.8" (H) x 4.5" (L)
UL: 60601-1, 1st Edition-2003
Limited 18 Month Warranty
To order call toll free: 877.224.0946
14029DP
14427 (Electric Pump)
PARTS:
80" (L) x 36" (W) x 8" (H),
Mattress Only, 1/ea
14029XP
Pump only, 1/ea
14029DP-CELL Replacement Bladder for 14029DP, 1/ea
14029DP-CELL 1 Replacement Bladder with Laser Holes
for 14029DP, 1/ea
450 LB
■
■
■
■
Dimensions: 80" (L) x 36" (W) x 10" (H)
10" static elevated perimeter
Base Material: zippered vinyl
Maximum Support Capacity: 450 lbs.
Limited 18 Month Warranty
NEW
DIGITAL
PUMP
DESIGN!
*Important Notice: Item numbers that display an asterisk (*) reflect an item that will be discontinued or package change.
14029XP
PRESSURE PREVENTION
■
15
Med-Aire Plus Alternating Pressure Mattress Replacement System
with Low Air Loss with Defined Perimeter
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement