iCAM7100S SERIES

HARDWARE GUIDE

A D V A N C E D M U L T I F A C T O R B I O M E T R I C I R I S R E A D E R

VERSION 1.0

iCAM7101S (Black Color) iCAM7111S-U1T (Titanium Color)

DUAL IRIS

CONTACTLESS

CARD READER

FACE CAMERA

ISO/ANSI

COMPLIANT

4.3” LCD

(7100S only)

EASY

INSTALLATION

• Fully automatic dual iris capture

• Simple non-intrusive, non-contact user interface

• Integrated megapixel face camera with LED flash

• ISO/ANSI compliant iris and face images

• 4.3” color touch screen LCD

• Integrated contactless smart card reader [optional]

• Surface mount plate included; Recess mounting kit [optional]

Packing List

What’s in the Box

iCAM7 series

Hardware Guide

L wrench

Required Equipment (not included)

Power Source

12-24 VDC +/- 10% / Minimum 24W (12VDC @ 2AMPS)

(Measured at iCAM unit)

Uninterruptable Power Supply (strongly recommended)

Network

Ethernet Wiring CAT5e Ethernet Cabling (or better)

Ethernet Switch

Software

Software required depending on Application

(See www.irisid.com for details)

iCAM7101S / iCAM7101S-T iCAM7111S-U1 / iCAM7111S-U1T

iCAM7 series Hardware Guide L wrench

2

Hardware Information

Camera Unit

Alignment Guide

Mirror

Face Camera

CCTV Camera (optional)

Screw Cap

Function Buttons

Speaker

Card Reader (optional)

Status LED

Front View

Bottom View

Tripod Socket

(1/4-20 (1/4 diameter, 20 threads per inch))

Rear View

Up / Down Tilt Buttons

Face Camera Flash

Proximity Sensor

Screw Cap

Function Buttons

4.3” Color Touch Screen LCD

Interface Panel

Cable Channel

Knock-out

Surface Mounting

Screw Hole

Desktop Stand Hole

Tamper Switch

Gang Box Screw Hole

Installation Plate

Hardware Information

Inside

Tamper

Switch

Wiring Legend

Guide

Input / Output

Connections

External GPIO

RS232 / RS485 /

RS422 Serial

Relay Output

Wiegand

Output / Input

Installation Plate Screw

RTC Battery

Power On/Off Switch

Power LED

Ethernet Connection /

USB 2.0 (Bottom)

Power Connection

External Speaker Jack

Factory Default Button

3

Installation Guidelines

1. Recommended Mounting Information

Bottom of

Mirror

7.01”

(178mm)

2.52”

(64mm)

61”

(155cm)

8.31”

(211mm)

54.3”

(138cm)

NOTE

This is based on the assumption that users’ average height is 5‘7”(170cm)

Floor

The recommended mounting height for the iCAM7 series is 138cm (54.3inches) from the floor to the bottom of the unit. This mounting height can be adjusted to accommodate the height of the average user at the installed location.

High amounts of ambient light must be avoided. Intense light sources such as sunlight or halogen lamps may reduce the image capture performance of the iCAM which may result in an increased “failure to acquire” rate.

The iCAM was designed for indoor use only. This device is not weatherproof and must not be exposed to precipitation or extreme temperatures. If it is required to use this product in an outdoor or extreme environment, a 3rd Party enclosure may be used to protect the unit from exposure to dust, moisture, and extreme temperatures. See www.irisid.com - Support &

Service for more information. Installation in a extreme environment without proper protection may cause permanent damage and void the warranty.

2. General Wiring Requirements

The iCAM7 series requires at least the following wires:

Ethernet network wiring to connect with the network switch for communication.

4 may be used.

IMPORTANT: IT IS RECOMMENDED THAT THE IRISACCESS SYSTEM BE PLACED ON A PRIVATE NETWORK

SEPARATE FROM GENERAL CORPORATE OR PUBLIC ACCESS. SYSTEM PERFORMANCE AND STABILITY MAY BE

AFFECTED DEPENDING ON AMOUNT OF GENERAL NETWORK TRAFFIC.

Power Adapter: The optional power adapter (iCAM7-PWR) can be used as the power source of the iCAM used for enrollment or other “non-installed” applications. The wires of the adapter should not be extended. If the power source is beyond the length of the power adapter then an external power source and wiring should be used. Be sure to observe the polarity of the adapter wires to the power screw terminals on the iCAM main board.

OR

Power and Wiring: For permanent installation it is recommended to use an external power supply and wiring.

• Power Supply: 12-24VDC +/- 10% - Minimum 24 Watts (24VDC @ 1AMP).

• Power Wiring: The recommended wire gauge for the ICU power is 18AWG (1.0 mm) wire.

drop must be accounted for in order to maintain the correct power at the ICU7000-2 unit. For wire lengths over 30 feet (9 meters) or if thinner gauge wire is being used (more than 18AWG) then it is required that a 24VDC power supply be used to overcome the wire length voltage drop. A 24VDC supply with 18AWG (1.0 mm) wire will allow for a distance of up to 200 feet (61 meters).

IMPORTANT: IT IS RECOMMENDED TO SUPPLY THE CORRECT AMOUNT OF POWER TO THIS UNIT. AN OVER OR

UNDER VOLTAGE APPLIED TO THIS PRODUCT MAY CAUSE PERMANENT DAMAGE AND VOID THE WARRANTY.

iCAM Installation

iCAM7 series Mounting & Stand Solutions

The iCAM7 series unit can be fitted to a surface mount (available out-of-the-box), recess mount

(with optional recess mounting kit), or optional desktop stand.

Surface Mounting

The iCAM can be surface mounted with standard equipment provided with the contents of your unit.

Review the following procedure for instruction on how to surface mount your iCAM7 series unit.

1

Open each cap at both sides of unit, and loosen the captive screws (with included L wrench) to release the interface panel.

(Left : MIC / Screw Cap.

Right : USB Connector / Screw Cap)

2

After opening the interface panel, loosen the screw.

Unscrew the installation plate screw to separate from the installation plate.

3

Separate the installation plate by sliding the plate downward.

Cover Rear

Installation Plate

5

4

Place the installation plate on the desired wall and screw into wall.

Feed any needed wiring through the installation plate hole (i.e.: Power, Ethernet, etc).

Attach the installation plate to the wall surface using the appropriate fastener (recommended

#10 screws) and anchors for the wall material. Another option is to mount and fasten the installation plate to a previously installed electrical gang box.

Surface Mount

Hole Marking

OR

Gang Box Mount

Installation Plate

6

Installation Plate

5

Slide the iCAM7 series into the installation plate and fasten the installation plate with a screw.

6

Remove protective film from RTC battery.

Power Supply

Connector

Power on

Ethernet

Cable

7

Before wiring unit, confirm the power is in the off position. Route and connect the Power and Ethernet wires to iCAM7 series.

section “Wire Connection Details” before closing interface panel and fastening screws.

8

Turn on power source and switch the power switch of the iCAM7 series unit to the ON position.

9

After wiring the unit and switching it to the ON position, close the interface panel and fasten the screws.

(with screw caps placed back into closed position).

7

Wire Connection Details

A B C D E

F

8

A

External GPIO

GPIO3 and 4 can be used to control the tilt position of the tilt unit of an iCAM7 series.

Use GPIO3 and GND for up tilting. Use GPIO4 and GND for down tilting.

GPIO Specifications:

• For output, the GPIO can provide 5VDC @ 20mA.

• For Input, the GPIO is selectable between active High & active Low.

• Assignment of GPIO is handled through Software

External Tilt

GPIO3

GROUND

GPIO4

GROUND

Up

Down

External GPIO

B

RS232 Output

RS232 serial communication port for connection with an access panel or to other computer equipment. When configured, the Card ID associated with the user is output from the

RS232 output port upon a successful identification.

TXD

RXD

GND

To RS232 port of computer or access system

RS232

Output

RS485 Output

RS485 serial communication port for connection with an access panel or to other computer equipment. When configured, the Card ID associated with the user is output from the

RS485 output port upon a successful identification.

TX/RX+

TX/RX-

To RS485 port of computer or access system

RS485

Output

RS422 Output

RS422 serial communication port for connection with an access panel or to other computer equipment. When configured, the Card ID associated with the user is output from the

RS422 output port upon a successful identification.

TX+

TX-

RX+

RX-

To RS422port of computer or access system

RS422

Output

9

10

C

Relay Output

IMPORTANT: ONLY KNOWLEDGEABLE PROFESSIONAL INSTALLERS SHOULD BE USED TO INSTALL ALL

ELECTRONIC ENTRY/EXIT LOCKING DEVICES. DIRECT CONNECTION OF ELECTRONIC ENTRY/EXIT LOCKING

DEVICES SHOULDN’T BE MADE FROM THE RELAY OUTPUTS ON THE ICAM. IT IS THE RESPONSIBILITY OF THE

INSTALLER TO ASSURE THAT THE INSTALLATION IS PERFORMED IN ACCORDANCE WITH ALL COUNTRY/STATE/

LOCAL FIRE AND SAFETY REGULATIONS AND THAT ANY 3RD PARTY PRODUCTS USED WILL NOT CREATE A

HAZARD.

Two independent dry contact relays. The purpose and the duration of the relays are defined by the controlling software. Typically, Relay_1 (NC_1, COM_1, NO_1) is triggered upon user acceptance (access granted). The diagram shows Relay_1 connected to indicators which changes from Red to Green for an accepted user. Relay_2 (NC_2, COM_2, NO_2) is typically used to indicate iCAM tamper. In this diagram the relay is activated when the iCAM tamper switch is triggered. The maximum electrical rating for the relay is 3A at 24VDC.

Relay Output

LIGHT

POWER

SUPPLY

RED GREEN

ALARM

SYSTEM

24 HOUR

ZONE

D

Wiegand Output

The Wiegand Output from the iCAM7 series camera unit can be used with 3rd party devices capable of receiving Wiegand data. This Wiegand output emulates a typical Access

Control Card Reader. Configuration of this output is provided through software.

See the associated image for general wiring of Wiegand Output to an Access Control Panel.

Wiegand Specifications:

• Wiegand output uses 3 wire interface (Data0, Data1, and Ground),

• Maximum wire length from iCAM to Access Control Panel is 500feet (152m).

Wiegand Output

Card Reader

Interface

GROUND

DATA_1

DATA_0

ACCESS

CONTROL

PANEL

E

Wiegand Input

Wiegand input is available on the iCAM for connection from 3rd party proximity card readers.

This connection can provide 12VDC and a maximum 300mA current to a proximity card reader.

Wiegand Intput

External

Prox Card

Reader

12VDC

DATA_0

DATA_1

GROUND

F

External Speaker Out

Allows for connection of an external amplified speaker. This port provides mono or stereo

(single channel) audio of voice prompts and other unit sounds. Both the internal and external speakers can operate concurrently.

Mono

Signal

Ground

To amplified speaker

3.5mm

Stereo

Ground

Left signal

Right signal

3.5mm

To amplified speaker

11

iCAM Configuration

The iCAM 7 Series camera contains a configuration interface called the iCAM Configuration.

This configuration interface allows the installer to setup the iCAM’s IP Address, IrisServer connection, and other configuration options.

How to access the iCAM Configuration interface

From a PC with an internet browser connected to the network (that the iCAM7 series unit is connected to), type the IP address of the iCAM. For example, if the IP address of an iCAM is

192.168.5.100 (default IP), you would access the configuration web interface by typing http://192.168.5.100 from an internet browser.

To login, the User ID required when prompted is iCAM7000. The Password is iris7000.

The system is case sensitive when entering in your login credentials.

Once you have connected to the iCAM Configuration Interface - settings, information, and options become available to further configure your system. Additional documentation for setup and configuration can be found at: http://www.irisid.com/productdocumentation

12

How to Operate

11~15”

(28-38cm)

Tilt down -25 Degrees

Read distance 14inches away

Tilt up +35 Degrees

Read distance 14inches

The on-unit up/down tilt buttons can be used to adjust the tilt angle; or an external mounted switch can be wired to control up/down tilt via GPI.

• iCAM activates when user approaches or when card is presented.

• Picture capture range is 11~15 inches (28-38cm) away.

• Self or auto/set height adjustment.

• Placing dot over the bridge of nose, easily helps alignment.

• Orange turns to green when user is at correct distance.

• Visual indication is amplified with friendly audio prompts.

• Right and left irides are acquired.

• A face picture can also be captured.

Green dot = In range Orange dot = Out of range

13

Restoring The Unit to Factory Default

Factory Default Button

The Factory Default Button can be used to restore the settings of the iCAM 7 Series to factory default. This button is located inside of the unit next to the power switch (see image), and can be used in two different ways:

Factory Default Button Function

Reset IP Address and Login Credentials

Reset all settings and reload software

Procedure

• Unit Power is ON

• Press and Hold the Factory Default Button for more than

3 seconds.

• Unit will beep when the default process has started.

• The iCAM IP Address will be reset to 192.168.5.100,

The Username to iCAM7000, and the password to iris7000.

• Power Unit OFF

• Press and Hold the Factory Default Button (FDB)

• While still holding the FDB, Turn ON the unit power

• Keep the FDB held in for at least 10 seconds.

• Stop holding the FDB

• Do not turn off the power to the unit or remove the network

connection for at least 10 minutes (the unit will reboot several

times on its own during the software reload process).

• When complete the iCAM will have reloaded the software and

reset IP Addresses and log-in creditenials to the defaults.

14

Memo

Serial Number:

Unit IP Address:

Installation Date:

Option 3 Iris Server IP:

Option 3 Security ID:

Note:

15

General Information

The iCAM7 series multifactor iris biometric reader contains a high-speed multi-sensor optical system which provides ISO compliant iris images. The iCAM7 series also contains a color face camera, an intuitive user interface, a built-in iris biometric template creation and matching processor, and an optional integrated card reader. The iCAM7100 series unit includes a touch-screen LCD display and

6 function keys to visual feedback to the user and allow for user input. Input and Output interfaces of the iCAM7 series units include Wiegand, Serial, and Relay.

Dimension (W x H x D)

Weight

Power Input / Consumtion

Status LED

Iris Operating Range Indicator

Voice Indication

Iris Capture Range

User Input

Touch Screen LCD

Pin Pad

Flash

Face Image Camera

Relays x 2

Operating Temperature

Storage Temperature

Humidity

Iris & Face Camera Rotation Angle

Communications

Inputs / Outputs

7.01” x 8.31” x 2.52” (178mm x 211mm x 64mm)

3.5lbs (1.6kg)

12-24VDC, 2.0 Amps @ 12VDC / 24W

Multi Color - Red, Green, Blue, Amber for status and alarm indication

Dual Color - Orange (out of range), Green (in range)

English and Korean standard, other languages available

11”~15” (28cm ~ 38cm)

Six user definable Function keys

4.3” diagonal (480 x 272 pixels)

Pop-up on screen pin pad

High output LED flash for face capture

Face camera CMOS - 5MP

Control for user defined operations

32°F~113°F (0°C~45°C)

-4°F~203°F (-20°C~95°C)

Up to 90% non-condensing

+35°/-25°

Ethernet (LAN, WAN), RS232 / RS485 / RS422

Embedded Card Reader (Optional), Wiegand In, Wiegand Out,

Dry Contact Relay x 2, Programmable GPIO x 4

Equipment Supplied with iCAM7 series Instruction Manual - Hardware Guide

Technical Support

Additional information and technical assistance is available on the Iris ID Systems support web site at www.irisid.com. Click on Support & Service then Technical Support.

formerly

Iris ID Systems, Inc.

7 Clarke Drive, Cranbury, NJ 08512, USA

Tel. 609-819-IRIS(4747) Fax. 609-819-4736

www.irisid.com

©2015 Iris ID, Inc. All rights reserved. Design and specification subject to change without notice.

Printed in Korea

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement