ADAPTDd
ADAPT Damper
Room product for Swegon’s WISE System for demand-controlled ventilation
ADAPT Damper
Quick facts
►► Integrated temperature sensor
►► Simple wiring: Plug and Play
►► Modbus RTU-communication
► ► Available as a package solution for
►► Detector module DETECT SME
energy saving in schools: School WISE
(accessory)
►► Clean Air Control CAC (option)
Quick Selection
Product with sound
attenuator
ADAPT Damper 125
q(l/s)
Cooling capacity (W) (DT 8K)
dB(A) nom*
min
nom
1 Pa/m
min
nom
1 Pa/m
50 Pa (P tot)
80 Pa (P tot)
0/4
35
38
40
340
365
≤ 35
≤ 38
ADAPT Damper 160
0/6
70
70
60
670
670
≤ 30
≤ 32
ADAPT Damper 200
0/10
140
140
100
1340
1340
≤ 30
≤ 32
≤ 32
ADAPT Damper 250
0/15
240
240
145
2300
2300
≤ 30
ADAPT Damper 315
0/25
430
430
240
4130
4130
≤ 30
≤ 32
ADAPT Damper 400
0/40
750
800
380
7200
7680
≤ 30
≤ 32
ADAPT Damper 500
0/60
1200
1500
575
11520
14400
≤ 30
≤ 32
* dB (A) values are approximate and are based on one or several ceiling air diffusers with insulated commissioning box in a normally sound-attenuated room.
Calculations have been made with a 500 mm long CLA downstream of the damper. Size of the room is based on an airflow of approx. 8 l/s m2 alt. 80 W/m2.
NOTE: The acoustic data should be used as guidelines only. Acoustic calculations are advisable for obtaining precise acoustic data.
1
WISE
Contents
Quick facts............................................................................. 1
Technical description...................................................3
Design.................................................................................... 3
CONNECT Adapt.................................................................... 3
Functions:............................................................................... 3
Air quality control, CAC.......................................................... 3
Humidity controll.................................................................... 3
Materials and finish................................................................. 3
Planning................................................................................ 4
Installation.............................................................................. 5
Commissioning....................................................................... 5
Maintenance........................................................................... 5
Declaration............................................................................. 5
Electrical data....................................................................... 5
Sizing............................................................................6
Airflow - Pressure drop - Sound level....................................... 6
Acoustic data for ADAPT Damper........................................... 6
Dimensions and weights..................................................... 7
Ordering key................................................................7
Accessories............................................................................ 8
DETECT Quality....................................................................... 8
DETECT SME presence detector.............................................. 9
DETECT Occupancy................................................................10
TUNE Adapt...........................................................................11
TUNE Temp............................................................................11
LINK Modbus.........................................................................11
LINK Tuneadapt.....................................................................11
FSR clamp..............................................................................13
ACTUATOR............................................................................14
2
Swegon reserves the right to alter specifications.
20151020
www.swegon.com
WISE
Air quality control, CAC
Technical description
Design
ADAPT Damper is a flow-controlled damper which is a part
of Swegon’s WISE system. The damper regulates the air
stream to the correct airflow based on preset absence, min.
and max. flows. ADAPT Damper is equipped with an integrated controller for all the relevant set values and control
functions. The damper also includes a built-in temperature
sensor for measuring the supply air and extract air flows.
The damper can close or open completely in response to
signals from a main control system, a so-called emergency
state function.
CAC, "Clean Air Control" is a gas mixture sensor that
measures the room's contamination degree. CAC controls ventilation flow to preset adjustable limits. For more
information about the sensor, see separate document at
www.swegon.com.
Air quality control
DETECT Quality is an external electronic CO2 detector,
used with ADAPT Damper for supply air and for controlling ventilation needs within the premises.
Humidity controll
CONNECT Adapt
A connection box, CONNECT Adapt, is included in every
damper delivery (Master), figure 2. The connection box
replaces the coupling box which otherwise is mounted on a
wall/ceiling for wiring damper with 24 V incoming voltage.
Materials and finish
ADAPT Damper is made of galvanized sheet steel and has
parts made of plastic, rubber. ADAPT DAMPER also contains electronic components. The connection box is made
of ABS plastic.
Heating in sequence, CO2-sensor, set point selector,
external presence detector and Rh-sensor. If the presence
detector is switched in, the presence signal can be fetched
for controlling the lighting, for instance, and in this way
save more energy.
8
5
6
16
4
- +C
9
15
11
10
5
4
6
A1 A2 1 3
0
24
NO
C
NC
G
OUT1
G0
12
1
3
2
7
13
Figure 1. Wiring of master/slave-units and accessories.
1. ADAPT Damper, Master unit (3VA).
2. ADAPT Damper, Slave unit (3VA).
3. CONNECT Adapt (conn. terminal).
4. POWER Adapt 230-24 V AC transformer.
5.
6.
7.
8.
LINK Adapt 5 m (RJ45 cable).
LINK Modbus 5 m (RJ 12 cable).
DETECT Occupancy (1 VA).
DETECT SME, Presence detector. Function control, temperature and occupancy detection.
*)
9. TUNE Temp (Can be combined with DETECT SME).
10.*) DETECT Temp (Redundant when DETCT SME is chosen).
11. *) DETECT Quality (Can be combined with DETECT SME).
12.*) Detect RH, moisture sensor (Can be combined with DETECT SME)
13. ACTUATOR, radiator- or cooling unit regulation (24V PWM), max 3 valves,
each at 6 VA.
14.SPLIT Link RJ12, branching for Modbus cable.
15.ADAPT Relay 24 V AC for lighting (<1 VA).
16.Modbus RTU, connection to zone damper or router.
*)
Swegon reserves the right to alter specifications.
5
2
6
3
Functions:
• Cools/heats and ventilates with air
• Two stage cooling with water in the second stage,
cannot be combined with heating
• Controls airflows with regard to temperature through
the accessories DETECT SME or DETECT Temp.
• Controls airflows with regard to presence through the
accessories DETECT SME or DETECT Temp.
• Provision for switching in a presence detector
• Available in version with air quality control, CAC
• Ventilation boost after long period of vacancy
• Provision for wiring to a CO2-controller
• Provision for wiring to a Rh-controller
• Provision for the manual setting of set points
• Has provision for connection to a main control system
(ModBus)
• Control of heating in sequence if two-stage cooling has
not been selected
• Performance check with Tune ADAPT. Connects into the
socket of ADAPT Damper for testing damper components.
• Performance check with DETECT SME, alarm via LED if
some component in the device is faulty or alternatively
by connecting Tune ADAPT into DETECT SME.
• Comfort control through the presence detector DETECT
SME or Tune ADAPT, connected to the output socket of
ADAPT Damper. Alarm is emitted via LED or display if
room temperature or CO2 values deviate too much from
their set values. The function is not activated at delivery.
1
14
9, 10,11 and 12 cannot be combined.
20151020www.swegon.com
3
ADAPT Damper
Both damper and box are equipped with RJ45 quick-fit
connector for quick and fault-free wiring. The device has
provision for connection to a main control system (BMS) via
ModBus. Connect the LINK Modbus accessory cable (RJ12)
between damper and box and the device is ready for the
main control system. The following control functions can
also be connected from the connection box:
DETECT Rh is an external electronic Rh-sensor. It is used
with ADAPT Damper to control the need of ventilation in
a building.
WISE
If possible access the classroom’s supply air and extract
air ducts from the corridor when you install the dampers.
This way you will avoid disturbing the students and teacher
holding class. Install the master damper on the extract
air duct. The room airflows are regulated with regard to
temperature and air quality. The installation of a presence
detector also makes it possible to use airflows and temperatures while there are no occupants in the room(s). The
presence detector can also be used for controlling the lighting, which will save even more energy and money.
Figure 2. CONNECT Adapt with concealed quick-fit connectors
and connection terminals.
Planning
ADAPT Damper sets itself to the correct airflow between
preset min. and max. values based on applicable set
points and sensor information. Available pressure must
not exceed 250 Pa. Max airflow is chosen with the
damper open to max 80%.The pressure drop upstream
of the damper must be considered with respect to sound
levels. See the sizing diagrams or quick selection tables.
Even if the dampers are flow-controlled, pressure control
is needed for each zone. This can be done either by the
air handling unit in smaller systems, or by CONTROL Zone
in larger systems. In installations with supply air damper
only, these must be supplemented with DETECT T. For
further planning instructions, see the Technical Section.
Figure 3. Conference room with variable airflow.
For further planning directions, see the section: WISE
System Engineering.
Installation example:
1
5
5 3
2
6
4
Conference room with variable airflow
Option 1 Control of temperature only by means of an integrated temperature sensor in the extract air damper.
Option 2 The addition of a presence detector and provision for
absence set points (flows, temperatures).
Option 3 Control of the air quality with the CAC clean
air function.
School WISE
Many of today’s schools are ventilated with constant
airflows. Substantial energy and money can be saved if
these systems are replaced with variable airflow systems.
The School WISE package is a complete kit for a normal
classroom. All the component parts (except the presence
detector) can either be fitted in the corridor which makes
installation possible all year round, or the installation work
can be done inside the classroom.
Figure 4.1. ADAPT Damper 315-M-CAC, Master, extract air
2. ADAPT Damper 315-S, Slave, supply air
3. CONNECT Adapt
4. DETECT Occupancy
5. LINK Adapt 5 m with quick-fit connectors
6. Installation cable, 3 wires, type EKKR
The zone, of which the classroom is part, must be pressure controlled for the function required. For further planning instructions, see the Technical Section.
• 2 pc ADAPT Damper Ø315, preset to 40-300 l/s, the
master damper (located in the extract airflow) is equipped with the CAC function, as standard.
• 2 pc LINK Adapt, RJ45 cable for wiring, L=5 m
• DETECT Occupancy
• Cable L=10 m to DETECT Occupancy
• Connection box, CONNECT Adapt
• 2 pc FSR, clamps
4
Swegon reserves the right to alter specifications.
School WIS
E
Figure 5. The School WISE package.
20151020
www.swegon.com
WISE
Installation
A length of straight duct > 2 times the duct diameter
downstream of a duct bend, T-piece or dimensional change
is required for correct operation. We recommend installation using an FSR clamp. See Figure 6. The exterior surface
of the entire product should be insulated if it is installed in
a cold space. To simplify wiring the TUNE Adapt, the LINK
Tuneadapt extension cord with terminal box is available for
installation in false ceilings. If installed in false ceilings, an
inspection hatch is also required to allow inspection of the
product.
Commissioning
ADAPT Damper is normally preset at the factory, either
with customer-specific or with standard settings.
Maintenance
ADAPT Damper is maintenance-free. Clean only by wiping
with a dry cloth. When cleaning the duct system, the ADAPT
Damper must be dismantled for cleaning if there are no
inspection covers nearby. Cleaning tools like whisks and the
like must not be drawn through the damper.
Presence
22 °C
±1K
Absence
22 °C
+3 /
-2 K
Night-time cooling
Air flows m /h (l/s)
3
Size 125
Absence*)
Min.
Max.
airflow airflow
8
Size 160
0/6
10
80
Size 200
0/10
15
125
Size 250
0/15
25
200
Size 315
0/25
40
300
50
Size 400
0/40
65
500
Size 500
0/60
100
800
*)
Possibility to set 0 as min. flow with the result of fully
closing the damper, for older controllers (until version 5.1)
the min. flow is 1 l/s which normally gives a closed damper.
The second displayed value refers to adjustable flow during
absence.
Air quality
CO2
Declaration of Construction Materials is available for
download from www.swegon.com.
17 °C
0/4
CAC (%)
Declaration
Rh - Relative humidity (%Rh)
Min.
Max.
25
35
800
1000
65
90
Presence
Electrical data
ADAPT Damper is supplied with power via the connection
box. See the wiring diagram.
For more information about various wiring and room solutions, see the Technical Section entitled: System Solutions.
Supply voltage
Temperatures
24 V AC -10% +10% 50-60 Hz
Switch on delay
Switch out delay
Modbus ID
9.600
8 bits
Word length
Cable rating
0.6 A
Stop bits
Storage
Parity
1
None
0°C - +50°C
-20°C - +50°C
Figure 6. Length of straight duct required upstream of ADAPT
Damper to compensate for various obstructions.
Swegon reserves the right to alter specifications.
1
Speed
3 VA
In-operation
20 min.
Communication
Max. power consumption
Ambient temperature:
0 sec.
Figure 7. Wiring TUNE Adapt for checking and changing set points.
If DETECT SME is chosen as an accessory the TUNE Adapt is connected directly to it.
20151020www.swegon.com
5
ADAPT Damper
The TUNE Adapt hand-held terminal is used for manually checking the current airflow through the damper and
for changing set points, if required. It can be connected
to the appropriate quick-fit contact on the side of the
damper. See Figure 7.
Standard settings for default products
WISE
Sizing
Acoustic data for ADAPT Damper
The diagrams for the various sizes show the total generated sound power (Lwtot dB), as a function of the airflow and pressure drop across the damper. The sound
power level for each octave band (LW = LWtot + Kok)can be
obtained by correcting LWtot with the correction factors
from Table 1.
Airflow - Pressure drop - Sound level
1.The data is applicable to flow-generated sound arising
in ducts.
2.The flow range of ADAPT Damper is specified in the
quick selection table.
3.Specified sound levels LWtot 50, 55, 60, 65 och 70 dB for
lines shown in the diagram.
4.Max. available pressure upstream of the damper ≤ 250 Pa.
0
-4
-9
-17
-20
-29
-34
-40
160
0
-4
-9
-19
-22
-27
-35
-39
200
0
-5
-9
-17
-19
-24
-31
-32
250
0
-6
-9
-14
-17
-19
-23
-26
315
0
-4
-10
-14
-17
-21
-28
-29
400
0
-4
-9
-12
-15
-20
-26
-25
500
0
-6
-6
-11
-14
-18
-26
-29
Tol. ±
2
2
2
2
2
2
2
2
500
400
200
100
100
50
40
50
40
30
30
20
20
10
10
5
10
20
30
20
40
50
30
40
100
50
100
200
300
200 l/s 300
400 500
5
10
20
m /h
30
40
1000
m
ax
55
300
50
ps Pa
30
40
100
50
200
100
300
200
400 500
300
400l/s500
3
1000 m /h
60
60
500
400
20
ADAPT Damper 250
m
in
ps Pa
5
50
3
ADAPT Damper 200
1000
60
55
m
in
4
ps Pa
300
50
3
125 250 500 1000 2000 4000 8000
125
200
5
Mid-frequency (Octave band) Hz
ADAPT D 63
m
ax
55
300
Size
m
in
m
ax
m
in
ps Pa
Correction factor Kok
ADAPT Damper 160
ADAPT Damper 125
500
400
Table 1
500
400
55
50
300
50
200
100
100
50
40
50
40
30
30
20
20
m
ax
200
20
40
30
50
40
100
50
200
100
300
200
400 500
300
400 500
l/s
1000
1000
40
2000 m /h
ADAPT Damper 315
ps Pa
20
30
50
1000
100
100
50
40
50
40
30
30
20
20
40
6
50
30
100
40
300
1000
400 500
l/s
1000
2000 m3/h
50
200
100
300
400 500
200
300
400 500
1000
Swegon reserves the right to alter specifications.
l/s
2000 m3/h
1000
55
50
m
ax
200
m
ax
200
20
200
400 500
60
300
50
10
10
100
300
65
500
400
55
300
50
200
ps Pa
60
500
400
40
100
ADAPT Damper 400
m
in
1000
10
10
3
m
in
10
10
10
20
30
100
20151020
40
50
200
100
300
400 500
200
300
1000
400 500
2000
1000
l/s
2000
3000 40005000 m3/h
www.swegon.com
WISE
ADAPT Damper 500
Ordering key
m
in
1000
ps Pa
Product
65
500
400
60
300
School WISE, complete package
55
50
c
-aaa
Size: 200, 250, 315
m
ax
100
50
40
Circular active room damper
30
20
10
20
School WISE
Version:
200
ADAPT D
d
-aaa
-b
-c
Version
30
40
100
50
100
200
300
200
400 500
300
400 500
1000
2000
1000
l/s
Standard sizes:
2000
125, 160, 200, 250, 315, 400, 500
3000 40005000 m3/h
M =Master
S = Slave
CAC = With CAC air quality control (extract air only)
0 = Without CAC air quality control
Dimensions and weights
ADAPT Damper
Size
Dimensions (mm)
Accessory
Weight
DETECT Quality
Temperature and CO2sensor with set point
selector knob
3,4
DETECT SME
External presence detector
45
3,8
A
C
ØD
E
F
G
(kg)
125
572
458
124
75
175
45
160
572
458
159
75
175
200
572
458
199
75
175
45
4,5
DETECT Occupancy Type IR presence detector for adjustment
between presence and absence
250
572
458
249
75
175
45
5,1
TUNE Adapt
315
572
458
314
75
175
45
6,0
Hand-held terminal for reading/changing settings
400
826
680
399
75
175
57
9,3
TUNE Temp
Temperature adjuster
500
826
680
499
75
175
57
11,3
DETECT Temp
Analogue temperature sensor
DETECT RH
Air quality sensor
LINK Modbus
RJ12-cable for connecting up Modbus
RTU
LINK Tuneadapt
Extension cord for outlet to TUNE Adapt
LINK Adapt
RJ45 cable for connecting up in other
lengths
LINK Wise
Network cable for Modbus, complies
with the EIA/TIA-485 standard
FIX Link
For securing cables to ducts, etc.
POWER Adapt
Transformer
ACTUATOR
Valve actuator, on/off
VALVE
Radiator valve
ADAPT Relay
Lighting control relay
ADAPT Triac
Semiconductor relay for lightning- or
heath controll
FSRb
Clamp for installation
Figure 8. Dimensions, ADAPT Damper.
1 = CAC sensor factory-fitted to the ADAPT Damper xxx-M-CAC.
Swegon reserves the right to alter specifications.
20151020www.swegon.com
7
ADAPT Damper
N.B.! Specify absence, min./max. airflows in your specification!
The CAC function can be combined with master and extract air
only.
WISE
Accessories
DETECT Quality
DETECT Quality is an electronic CO2 sensor used with
ADAPT Damper for supply air and for controlling ventilation needs in premises. External presence detector DETECT SME is required for full functionality; performance
check, occupancy and room temperature detection.
Preset values are managed by ADAPT Damper. As an
alternative, there is a CAC function integrated into ADAPT
Damper for extract air, which then becomes master.
Quick facts:
• CO2 sensor
• Measuring range: 0-2000 ppm
• Output signal 0-10 V
Figure 9. DETECT Q-0
Electrical data
Supply voltage
24 V ±20 % AC/DC
Power consumption
Ambient temperature
3 VA
0 °C – +50 °C
Reaction time
Humidity
2 min.
0-95% RH (non-condensing)
Degree of protection,
installed in a room
IP 20
OUT1 0-10 V DC
0-2000 ppm
Ordering key
Carbon dioxide sensor
DETECT Q
a
-a
Version:
Type: Without display: 0
8
Swegon reserves the right to alter specifications.
20151020
www.swegon.com
WISE
DETECT SME presence detector
10
DETECT SME is an external module equipped with a
occupancy presence detector, temperature sensor, operation indicator and connection for TUNE Adapt hand terminal. The module has limited presence detection, hence
importance of placement. In larger rooms the DETECT O
is a necessary complement to eliminate blind zones. The
presence detector is only intended for surface mounting
and must be used with a surface mounted cable duct (not
included in delivery).
20
110
0
Ø 11
DETECT SME must not be mounted in logations exposed
to sun light, this affects both temperature measurement
and presence detection negatively.
Quick facts
• Occupancy presence detector of IR-type
• Room temperature sensor
• LED operation indicator
• Connection for TUNE Adapt
• Delivered with 10 m connection cable
10
20
20
110
ADAPT Damper
Figure 10. Dimensions for DETECT SME
(cable duct is not inluded in delivery).
Detection
The presence detector is divided in sectors, 6 placed
horizontally and 3 vertically (not shown in figures). For
detection to take place, movement between two sectors
is required. The further away from the unit this happens,
the larger the movement required, as the sectors grow
larger with distance. In figure 11, the central sectors are
highlighted in green. Sector size corresponds approximately to 1/6 of the value from measurement B.
Occupancy presence sensor – detection area
Electrical data
A
B
H
B/6
1,5
2,6
3,0
0,4
2,5
4,5
4,0
0,8
4
7,0
5,6
1,2
6
10
7,6
1,7
All measures are displayed in meters.
Power supply via ADAPT Damper
Ambient temperature
0 °C – +50 °C
Degree of protection, installed in a room
IP 30
Ordering key
Presence detector
DETECT SME
a
-a
-bb
Version:
Type:
1 = Wall mounted
2 = Corner mounted
Connection cable:
10 meters
1,5
Figure 11. Detection area when DETECT SME is mounted 1,5 m
above floor level. The presence detector is placed at the middle
of the endwall in the room. Max, recommended room depth is
6 m. Note that the detection width then is 10 meters. Corner
mounted version covers the whole room, penetration depth is
still max 6 m.
Swegon reserves the right to alter specifications.
20151020www.swegon.com
9
WISE
DETECT Occupancy
DETECT Occupancy is an IR type presence detector for
use in combination with ADAPT Damper for readjusting
between presence and absence of occupants. Adjustable
on/off switching delay. Available for wall or ceiling mounting. A mounting bracket that enables angular adjustment
of the sensor for optimal coverage of the room is included
for the wall-mounted variant.
Quick facts:
• IR detector of double enclosure type
• Available for ceiling or wall installation
• Normally open and normally closed changeover contacts
• Adjustable on/off switching delay
• White enclosure
Figure 12. DETECT Occupancy.
Note: Settings of on/off-delay is done in DETECT Oa, settings in
ADAPT are not vaild.
Electrical data
Supply voltage
24 V ±2 V AC/DC
Power consumption
Ambient temperature
1 VA
-20 °C – +50 °C
Degree of protection, installed in a room
IP 20
Max. detection area
15 x 15 m
Ordering key
DETECT Occupancy presence detector
DETECT O
a
-aaa
Version:
Type:
Wall mounted: V110
Ceiling mounted: T360
DETECT Temp
DETECT Temp is an analogue temperature sensor that can
be used instead of DETECT SME when:
• ADAPT Damper is master of supply air.
• ADAPT Damper is master of extract air, with heat regulation, while the unit is closed.
Quick facts
• Thermistor for room temperature
• 10-30° C range of application
• 0-10V DC signal out
Electrical data
Supply voltage
24 V AC ±10%
Power consumption
1 VA
Outputs: 0-10 V max load
Figure 13. DETECT Temp
10 mA
Degree of protection
IP 30
Ordering key
Temperature sensor
DETECT T
a
Version:
10
Swegon reserves the right to alter specifications.
20151020
www.swegon.com
WISE
TUNE Adapt
Hand-held unit for checking and setting values such as
temperatures, CO2 limits and airflows. Compatibility of the
hand-held micro terminal: An older TUNE Adapt can always
read all the later versions of the controller, a newer version
of TUNE Adapt cannot read older controller variants.
Note: All the ADAPT products with version letter designation
b are of Version 5.
• Simple connection directly to the air diffuser
• Supplied with power via the air diffuser
• Illuminated display window
• Simple and logical menu structure
Figure 14. TUNE Adapt
Ordering key
TUNE A
b
-bbb
ADAPT Damper
TUNE Adapt hand-held terminal
Version:
Language
1 = EN, SE, DK, FI, NO
2 = EN, RU, PL, EST
3 = EN, DE, FR, NL
Note: All the ADAPT products with version letter designation b
are of Version 5.
TUNE Temp
TUNE Temp is a wall-mounted set point selector for room
temperature in applications where the user shall be able
to enter settings.
• Set point change ± 3°C.
• Output signal: 5 ± 5 V DC
Figure 15. TUNE Temp
Electrical data
Supply voltage
Power consumption
Outputs: 0-10 V max load
Degree of protection
24 V AC ±10%
1 VA
10 mA
IP 30
Ordering key
TUNE Temp set point selector
TUNE T
a
Version:
LINK Modbus
RJ12 modular cable for wiring between master diffuser/
damper and CONNECT Adapt for a main control system.
Figure 16. LINK Modbus
Ordering key
LINK Modbus RJ12 cable
Version:
Length: 2, 3, 5 or 10 m
LINK M
a
-aa
LINK Tuneadapt
The RJ12 modular cable for extending the outlet for TUNE
Adapt, permits contact from room level with the ADAPT
Damper installed high above the false ceiling.
Ordering key
LINK Tuneadapt RJ12 cord with outlet
LINK T
a
-aa
Version:
Length: 6, 10 or 14 m
Swegon reserves the right to alter specifications.
Figur 17. LINK Tuneadapt
20151020www.swegon.com
11
WISE
LINK Adapt
RJ45 modular cable for wiring between master diffuser/
damper and CONNECT Adapt if lengths other than those
which included in the supply are needed.
Ordering key
LINK Adapt RJ45 cable
LINK A
a
-aa
Version:
Length:
2, 3, 5 or 10 m
5 m is standard and is always included in a delivery
Figure 18. LINK Adapt.
SPLIT Link
Fork operation allowing more diffusers to be connected
to a master/slav group by using LINK Adapt or LINK Modbus to connect from one diffuser to another.
Specifikation
SPLIT Link Fork operation
SPLIT L
a
-aaa aa
Type:
SPLIT Adapt = LAa 45
SPLIT Modbus = LMa 12
Figure 19. SPLIT Link.
FIX Link
Fix Link for fixing cords to ducts, for example. The holder
is inserted into a 6 mm dia. drilled hole and is self-locking.
The bundling strap locks the cords in place.
Ordering key
FIX Link cable attachment, 100 pack.
FIX L
a
Version:
Figure 20. FIX Link.
POWER Adapt
Single phase protective transformer for main plug connection, unearthed or earthed. The transformer is made of
impact-resistant, light grey, self-extinguishing thermoplastic. POWER Adapt manages to operate a normal office
room with 2 pc ADAPT dampers and up to three radiator
valves. Meets applicable requirements for electrical safety/
emissions and immunity.
Technical data
Input voltage
Output voltage
Capacity
Enclosure:
230 V 50-60 Hz
24 V AC
20 VA
IP33
Figure 21. POWER Adapt.
Ordering key
Single-phase transformer
POWER A
a
-aaa
Version:
Size: 20 VA, 60 VA, 150 VA
Figur 22. POWER Adapt 60/150 VA.
12
Swegon reserves the right to alter specifications.
20151020
www.swegon.com
WISE
ADAPT Relay
Relay for on/off control of the lighting, designed for installation in a wall terminal box or the like. As an alternative,
the relay can be supplied with a type CONNECT Adapt
round enclosure conforming to degree of protection IP30.
Electrical data
Supply voltage
24 V ±2 V AC/DC
Power consumption
0,5 VA
Circuit-breaking capacity
10A/250 V AC
Incandescent and halogen lamps
2000 W
Fluorescent lamp load with KVG with
lead-lag compensation or uncompensated
1000 VA
Fluorescent lamp load with KVG or
shunt coupling or with EVG
500 VA
I on
< 70A/10ms*)
ADAPT Damper
Compact fluorescent lamps with EVG
and low energy lamps
*)
You must pay attention to the inrush current of electrical HF
devices; an electric current monitor relay is recommended.
Ordering key
ADAPT Relay
ADAPT R
a
-a
-24/230 V AC
Version:
Enclosed= C
Not enclosed= N
Figure 23. ADAPT Relay in non-enclosed version (N) and enclosed (C).
Control voltage/Recovery voltage
FSR clamp
Clamp made of galvanised sheet steel, used for facilitating
installation and removal of damper units. The clamp has
adjustable eccentric locking devices for simple and quick
locking/opening. The rubber gasket allows sealing directly
against duct nipple. Always fit the clamp on the “room
side” of the damper.
20
Quick facts
• Thick rubber seal
• Adjustable eccentric locking devices
Figur 24. FSR, clamp.
Size
ØD (mm)
Weight (Kg)
125
124
0,7
160
159
0,9
200
199
1,1
250
249
1,3
315
314
1,5
400
399
1,9
500
499
2,2
Ordering key
Clamp
FSR
c
-aaa
Version:
Size: 125, 160, 200, 250, 315, 400, 500
Swegon reserves the right to alter specifications.
20151020www.swegon.com
13
WISE
ACTUATOR
Thermo-actuator, on/off in NC version with pin-connection cable ends. NC = Normally closed.
Power supply:
24 V AC/DC, ±10%, 0-60 Hz
Temperature:
Operating temperature, room air: 0-60 °C
Operating temperature, energy carrier: 10-100 °C
Cable:
Fixed two-wire cable, L= 1.0 m, Ø 0.75 mm2
Power consumption, start:
6 VA for a maximum of 2 min.
Power consumption, operation:
1.8 VA
Degree of protection:
Connection:
IP 54
As standard, the VA-80 adapter is included,
fits an M30 × 1.5 mm threaded socket.
Figure 25. ACTUATOR damper blade position indicator.
The actuator’s cylinder shaped position indicator clearly shows,
from all angles, which operating setting is current. When the
indicator is at its lowest position and at the same height as the
enclosure, the actuator is in closed position. When the indicator
is in the raised position above the enclosure, the actuator is in
the open position.
For alternative adapters contact Swegon.
”First open” function
The actuator is set to the ”first open” function on delivery. This means that the actuator is open when it is
installed making it easier to pressure test and vent the
water system. The function will be automatically disabled after the actuator has been energized for approx.
6 minutes. A clicking noise will be heard after which the
actuator will change over to the NC mode and the normal
regulation function will begin.
Ød
Ød
CL
Ordering key
Valve actuator
ACTUATOR
CL
VALVE
Radiator valve of angled or straight design. Dull nickelplated bronze.
Max. allowed operating pressure:
1000 kPa
Max. allowed pressure drop:
Across open valve: 20 kPa
Figure 26. VALVE-S valve and VALVE-A respectively with
ACTUATOR valve actuator mounted.
E = M30 x 1.5 mm threaded mount
Across closed valve: 150 kPa
Min. allowed inlet flow temp.:
110 °C
DN
Threads
S 110
Version:
S 115
Straight version = S
Angled version = A
DN: 110, 115 or 120
Ordering key
Radiator valve
14
VALVE
a
Swegon reserves the right to alter specifications.
-a
-bb
Dimensions (mm)
A
B
C
kv value
3/8”
59
26
81
0.09-0.63
1/2”
61
33
81
0.10-0.89
S 120
3/4”
63
35
81
0.31-1.41
A 110
3/8”
49
20
81
0.09-0.63