220 V Instructions
Installation/Operating Instructions
US Patent No.
6,379,012
220 V Revelation Video Projector Mount by Draper
These Installation/Operating Instructions are available in the official language
of the country where you purchase the product. Please contact your
distributor to request a copy.
Vous pourriez demander les instructions d’installation et d’opération traduises
dans la langue officielle du pays ou vous achetez le produit. Veuillez
demander à votre distributeur.
Die Gebrauchsanweisung für Installation und Konstruktion sind in der
offiziellen Sprache des Landes, indem Sie das Produkt gekauft haben,
vorhanden. Fragen Sie die jeweilige Verkaufs-Abteilung.
Caution
1 Read instructions completely before proceeding.
2 Follow instructions carefully. Installation contrary to instructions
invalidates warranty.
3 Take great care when handling both first surface mirrors. They will
usually come covered with a protective film. Remove this film after
installation and prior to projecting images. If cleaning is necessary, do
so very lightly with glass cleaner and a soft, lint free cloth.
4 Do not obstruct operation of door with fingers or any object. Serious
injury or damage could result.
5 The Revelation is not designed to act as a structural support of ceiling
framing. However, the trim frame is designed to support ceiling T-grid,
tiles and drywall. Equipment should not be allowed to rest on door
at any time.
6 Entire bottom of unit must be unobstructed to permit proper operation.
Sufficient clearance (432mm minimum) must be allowed below door.
7 A minimum clearance of 458mm is required above ceiling level for
model B or 347mm for Model A, if Environmental Airspace Housing is
used. If no Environmental Airspace Housing, the minimum clearance is
331mm for both models.
8 Unit must be installed level (use a carpenter’s level).
9 Unit operates on 220 V a.c. 60 hz. current.
10 Please Note: The Revelation is not compatible with lenses that have a
throw distance of less than 1.5:1.
Note: Unit has been thoroughly inspected and tested at factory and found
to be operating properly prior to shipment.
Where to install the Revelation
To determine where to mount the Revelation, you need to know the following:
1 The projector manufacturer’s recommended throw distance (TD). Typically,
a minimum and maximum range is provided per screen size. Select a
throw distance that is 6" greater than the minimum and 6" less than the
maximum stated. We recommend the average of the two numbers. For
example, if the range given is 228" max. and 142½" min., then use a
number between 222" and 148½". We recommend using the average of
185¼" as the TD.
2 The distance from the center line of the lens to the bottom of the projector’s
feet (CL). To find the mounting point (m = back edge of the rough cut) use
the following formula:
y = 15" + CL
z = TD – y
m = z + 8"
Remember:
CL = Distance from center line of lens to bottom of projectors feet.
TD = Manufacturer’s horizontal throw distance for the selected screen size.
m = Calculated mounting point (mounting point is back edge of rough cut as
measured from screen surface.)
As an example, if you are using a projector with recommended throw distance
(TD) of 185¼" for a 100" diagonal image, and its CL dimension is 4", calculate
the mounting point as follows:
y = 15" + CL
z = TD – y
m = z + 8"
y = 15" + 4"
z = 185¼" – 19"
m = 166¼" + 8"
y = 19"
z = 166¼"
m = 174¼"
In the example above, the distance from the screen to the back edge of the
rough cut would be 174¼". (Formula has a ± 6" accuracy).
y
m
z
= CL
As Soon As Revelation Arrives
1 Open carton and inspect for damage.
2 Locate the following parts:
A. The unit itself
B. Controls
Formula to find m
(mounting point is back edge of rough cut
farthest away from projection screen).
Planning
1 Based on screen location and projector specifications, determine proper
position for projector installation. (First see "Choose a projector based
on its light path" on page 3. Then read "Where to install the
Revelation" below.)
2 Confirm that there is at least 458mm available above the ceiling for Model
B or 347mm for Model A, if Environmental Airspace Housing is used. If no
Environmental Airspace Housing, the minimum clearance is 331mm for
both models.
3 Arrange to provide service access to electrical control box and
Environmental Airspace Housing.
4 If connecting duct work to the Environmental Airspace Housing, plan for
position and length of duct work. (See guidelines under "Installing the
Environmental Airspace Housing Kit" on page 6.)
Metric Conversion
1 inch = 25.4 mm
1 inch = 2.54 cm
Copyright © 2015 Draper Inc. Form Revelation220V_Inst15
Printed in U.S.A.
y = 15" + CL
where:
z = TD – y
m = z + 8"
CL = centerline of lens to bottom feet
TD = throw distance
Accuracy: ± 6"
Please Note: The Revelation is not compatible with lenses that have a
throw distance of less than 1.5:1.
Hanging Unit
The Revelation may be installed in a variety of ways. Typically, it is recessed
above the ceiling and supported by six (6) 3/8" threaded mounting rods. The
bottom of the main pan should be recessed approximately 76mm above
the finished ceiling. The threaded rods should pass through mounting holes
supplied in each corner and secured by nuts above and below. The unit
should then be guy wired or blocked to prevent swinging.
All installations should observe the following guidelines:
1 Installer must ensure that all fasteners and supports are of adequate
strength to securely support Revelation and projector.
2 Fastening methods must be suitable for mounting surface, and securely
anchored so that vibration or abusive pulling on unit will not weaken
installation.
3 Unit should be level, with weight shared more or less equally by all six
threaded mounting rods.
Continued on page 2
220 V Revelation by Draper
Page 2 of 8
4 Bottom of unit must be unobstructed after installation. 432mm minimum
clearance is required below the door.
5 Access should be provided to electrical control box in case service is
required.
6 Do not use unit to support adjacent light fixtures, etc.
7 Do not complete the ceiling below unit until electrical connections have
been completed and unit has been operated successfully.
8 We recommend that safety cables be attached to the Revelation for
added security (a sound installation practice with overhead equipment).
Electrical Connections
Unit operates on 220 V a.c., 60 Hz. current.
Opening the access cover on the electrical control box exposes terminals
for field connections. Unit is shipped with internal wiring complete. Wire for
connecting unit to switch(es) and to power supply should be furnished by
electrician. Connections should be made in accordance with wiring diagram
on page 5, and wiring should comply with national and local electrical codes.
All operating switches should be “off” before power is connected.
Operation
Caution: Keep fingers and other objects away from unit when it is
operating. Serious injury or damage can result.
When unit is first operated, be cautious! If door does not begin to open
momentarily when switch is flipped “down”, return switch to “off” and free door
and/or recheck electrical connections before proceeding. Cycle door down
and up several times to confirm satisfactory operation.
Single Station Control (CE Approved)—Moving 3-position switch to “down”
position will start door down. Moving switch to “up” will start door up. When
door is fully down or fully up, it will automatically be stopped by factory set
limit switches. Whenever switch is placed in center “off” position, operation will
stop.
Multiple Station Control—Each switching station has a three-button switch
with “up”, “down”, and “off” buttons. Door starts up or down when appropriate
button is pressed, and may be stopped by pressing “off” button. Factory set
limit switches stop door automatically when door is fully up or fully down.
Key Operated Switch—If ordered, a single station, key-operated three position (up/off/down) switch is available for this unit.
Video Interface Control (VIC12, VIC12 Modified)—This optional control
device allows the Revelation switch to control the operation of a Draper
motorized projection screen via relay.
Infrared or Radio Frequency Remote Control (CE Approved)—A three-button transmitter is provided, with “up”, “down”, and “stop” buttons. Door starts
up or down when appropriate button is pressed, and may be stopped by
pressing “off” button. Factory set limit switches stop door automatically when
door is fully up or fully down.
Installing Projector
The Revelation has a grounded 220 V a.c., 60Hz outlet for projector power
supply. Power is supplied to this outlet at all times.
Holes are provided for power and control wiring.
Install a projector with the capability to invert its image.
Place the projector into the sliding inner pan so that the center of the projector
lens is aligned L to R with the center of the upper mirror. Position the projector
lens as close as possible to the upper mirror without the reflected light path
striking any part of the projector. An extension plate is provided if the feet
of your projector rest inside the opening of the inner pan. The extension
is designed to support the front legs of your projector and the folded up edge
can be used as a stop to help reposition the projector when removed. Adhere
the extension plate only after you have adjusted the image and marked the
position of the plate.
Establish exact placement through trial and error using the various adjustments integrated throughout the design of the Revelation. The upper mirror
www.draperinc.com
can be moved up one inch to accommodate taller projectors. Make the necessary connections and plug the power cord of the projector into the receptacle
provided in the electrical chassis. Power to the Revelation should be turned
off any time electrical connections or mechanical adjustments are made
to the Revelation! Cycle the mirrored door down to the lowered position. You
are now ready to move on to adjusting the image to the screen.
Adjusting Image
First, use your projector’s operating manual to establish proper orientation of
the image and adjust the lens position to achieve the desired image width and
location.
Next, use the Revelation's adjustments to adjust the height of the image on
the screen.
The Revelation has two adjustments:
1 Always start by sliding the inner pan which holds the projector either backward or forward depending on desired location of image. Sliding the inner
pan towards the projection screen will change where the image strikes the
mirror on the door, and lower the projected image. Inner pan has a travel
range of approximately 8".
2 Opening the mirrored door even further into the room will lower the
projected image. The limit switch is factory set to let the door open into
the room at a 45° angle. The door can open approximately 10° farther
by changing the limit switch’s position. You can also tip the front of the
projector up toward the first mirror. This adjustment allows the image to be
projected farther down from the ceiling, but still introduces keystone into
the image. This adjustment offers the same adjustment feature as opening
the mirrored door up farther into the room without adjusting the mirrored
door's limit switches.
Adjust the door only if your projector is equipped with keystone correction or a
certain amount of keystoning can be tolerated.
To adjust the limit switch of the door:
TOOLS: screwdriver/Allen wrench (3/16"); electronic level or protractor or other
tool to measure angles.
Turn the unit on and open the door to its factory set position. Record the angle
measurement.
Caution: Any adjustments to the limit switches should be done with the
power to the Revelation turned off!
Locate the two limit switch brackets at the edge of the top mirror on the motor
side of the pan. The top bracket controls the downward travel limit of the door
and adjustments are made to this bracket. Note and mark current location of
limit switch bracket. The bottom limit switch bracket is set at the factory for
proper closure alignment and should not need adjusting.
Use a 3/16" Allen wrench to loosen the two screws on the limit switch bracket
and slide the bracket toward the electrical chassis. A slight adjustment to the
limit switch bracket will result in a significant movement of the door. It is recommended that the limit switch be adjusted in small incremental moves of 1/8".
Tighten the screws. Keeping hands and tools clear of the limit switch, connect
the power. The door should open further. Record the new angle and check the
position of the image on the screen.
If the position of the image on the screen is satisfactory, close the door and
make sure the screws are completely tight.
If the position of the image needs adjusting, leave the door open, disconnect
the power, loosen the screws and slide the bracket toward the motor to open
the door more, or slide the bracket closer to its original position.
Check alignment of image and repeat adjustment procedure as necessary. After all adjustments are completed, be sure to tighten all loosened
screws to inner pan and limit switch bracket!
Please Note
If Glass Shield is provided, see separate instructions (provided
with Glass Shield).
(765) 987-7999
220 V Revelation by Draper
Page 3 of 8
Securing Projector
Once all adjustments to the projector and Revelation are made, the projector
should be secured into place using the eight projector standoffs provided. Two
of the standoffs have a removable hook and loop material to be used at the
rear of the projector for ease of removing the projector. The standoffs will ensure proper relocation of the projector after periodic maintenance or repair to
the projector. Just peel the adhesive backing from the bottom of the standoffs
and place them around the projector as shown in the dimensional diagram.
Important: Once the adhesive is placed onto the surface of the inner pan it is
very difficult to remove. It is very important to plan ahead when placing these
standoffs around the projector.
Choose a projector* based on its light path
A light path is the projector’s spread of light and its relationship to the centerline of the lens. Since the Revelation folds a light path twice (bounces the
image off of two first surface mirrors), it’s critical to understand your projector’s
light path to know approximately where the image will land on the wall. Consult the projector's manufacturer to determine its light path geometry.
A
Single lens projectors fall into one of four categories of light path geometry as
depicted in the illustrations at right.
Light Path A
Single lens projectors with light path geometry “A” work well with the Revelation. Since the light is already projecting at a downward angle to the centerline, the image is projected further down on the wall resulting in a lower
installation point for the projection screen. A projector with Light Path A
mounted in the Revelation projects a light path similar to the same projector
ceiling mounted with the centerline of its lens mounted approximately 5176mm (2"-3") below the ceiling.
B
Light Path B
Single lens projectors with light path geometry “B” will work with the Revelation within certain limitations. The upper edge of the image runs parallel
to the centerline of the lens. A projector with Light Path B mounted in the
Revelation projects a light path similar to the same projector ceiling mounted
with the centerline of its lens mounted approximately 153-203mm (6"-8")
below the ceiling. By using the built in adjustment features of the Revelation,
you should be able to bring the top of the image below the ceiling. Adjusting
the ceiling closure door may introduce a keystone effect to the image. If your
projector has a keystone correction feature you may be able to compensate
for keystoning.
C
Light Path C
Single lens projectors with light path geometry “C” will work with the Revelation within certain limitations. The portion of the image above the centerline
of the lens projects at a gradual angle up towards the ceiling. A projector
with Light Path C mounted in the Revelation projects a light path similar to
the same projector ceiling mounted with the centerline of its lens mounted
approximately 153-203mm (6"-8") below the ceiling. By using the built in
adjustment features of the Revelation, you should be able to bring the top of
the image below the ceiling. Adjusting the ceiling closure door may introduce
a keystone affect to the image. If your projector has a keystone correction
feature you may be able to compensate for keystoning.
Light Path D
Single lens projectors with light path geometry “D” will not work with the Revelation. The portion of the image above the centerline of the lens projects at
too steep of an angle to be lowered below ceiling level, even with the adjustment features built into the Revelation.
D
*Consult your projector manufacturer if in doubt about its light path geometry,
throw distance or projector dimensions. Also, be sure your projector has the
ability to invert its image.
Please Note: The Revelation is not compatible with lenses that have a
throw distance of less than 1.5:1.
www.draperinc.com
(765) 987-7999
220 V Revelation by Draper
Page 4 of 8
Revelation Dimensions
6 Mounting
holes 9.525mm (3/8") dia.
TB1
Electrical
hook-up
252
mm
972
mm
603
mm
17mm
394mm
946
mm
462mm
Lens and mirror
centerline
*4
17mm
578mm
*1
8 Projector
standoffs
Projector
165
mm
*2
*1
*2
*3
*4
4"
*2
*3
Model A Model B
232mm 475mm
330mm 457mm
864mm 1118mm
546mm 630mm
5mm
17mm
603mm
m=Back edge of rough
cut to screen surface
Minimum clearance
without
Environmental
Airspace Housing
76mm 330mm
Ceiling line
103
mm
m
Model A
Electrical Specifications
Model B
Overall Unit Size (HWL)
330 x 972 x 864mm
330 x 972 x 1118mm
Required Space Above Ceiling*
346 x 972 x 864mm
458 x 972 x 1118mm
Clearance Below Ceiling
approx. 432mm
approx. 432mm
Rough Ceiling Opening
597 x 597mm
597 x 597mm
Capacity
45 kg
45 kg
Door’s Downward Travel Distance
approx. 432mm
approx. 432mm
Travel Time
9 sec.
9 sec.
Net Weight
39 kg
41 kg
Shipping Weight
98 kg
100 kg
Projector Space (HWL)—To fit within parameters of inner pan.
* 346mm is overall height of Revelation with Environmental Airspace Housing (330mm
WITHOUT Environmental Airspace Housing).
www.draperinc.com
25
mm
Minimum rough opening
597mm x 597mm
Minimum clearance
(Includes allowance
for Environmental
Airspace Housing)
Models A & B-346mm
Revelation Dimensions & Data
51mm
248
mm
65
mm
Operating Voltage
220 V a.c. 50–60 Hz
Amperes
1 Amp**
Control Voltage
12 V a.c.
Motor Specifications:
Voltage
220 V a.c. 50–60 Hz
Amps
.43
Torque
40 IN–lbs.
* Includes allowance for Environmental Airspace Housing.
** Does not include any load placed on internal outlet.
U.S. patent number 6,379,012
(765) 987-7999
220 V Revelation by Draper
Page 5 of 8
Wiring Diagrams for Revelation without Environmental Airspace Housing
Single Station Control
COMPONENT SPECIFICATION
SYM.
BE
1
YL
3
5
C1
6
BK
BK
RD
2
7
PRIMARY SIDE
YL
8
SECONDARY SIDE
T1 WIRING
WALL SWITCH
SPDT CENTER OFF
Capacitor 100mfd 35 Vac
CR1
Relay 12Vac 2PDT 230 Vac 10A
CR2
Relay 12Vac 2PDT 230 Vac 10A
D1
Diode NTE125002B
F1
Fuse 7 Amp AGC 250 Vac
F2
Fuse 1 Amp AGC 250 Vac
F3
Fuse 1 Amp AGC 250 Vac
T1
Transform 230V/[email protected] 50/60Hz
MOTOR 220V .03hp 50hz. 200Lb-in. 1.1rpm
TB 1
UP
BK
RD
2
C2
3
BE
YW
BE
CR 1
YW/GN
BE
UP
4
D1
TB 2
BE
SEE T1 WIRING DIAGRAM
BK
7
BE
8
YW/GN
10 11 12
GND
N
L1
WH
BE
BK
RD
RD
RD
C1
YW
BE
RD
BE
DOWN
T1
9
220 VAC SUPPLY
50 - 60 HZ
RD
CR 2
YW
RD
BE
BE
YW
14 AWG
RD
14 AWG
RD
BE
RD
14 AWG
PCB 1
F2
F1
CB1B
WH
RD
RD
BE
BE
MOTOR
DOWN LIMIT SW
UP LIMIT SW
BE
BE
BE
WH
BE
1
1 2 3 4 5 6 7 8 9 10
BK
YW/GN
PROJECTOR OUTLET
BK
BE
F3
RD
10 9 8 7 6 5 4 3 2
RD
RD
1
WIRING DONE BY INSTALLER
BK
2
BE
YW/GN
9
RD
8
10
RD
BE
7
6
RD
6
5
BK
5
BK
BK
BE
4
BE
RD
1
DOWN
3
COM
Capacitor 2mfd +/- 370 Vac
C2
WH
RD 14 AWG
CB1A
ALL WIRES 18 AWG. UNLESS OTHERWISE SPECIFIED.
Low Voltage Multiple Station and Remote Control
COMPONENT SPECIFICATION
BE
1
SYM.
YL
3
5
BK
Red
Brown
Yellow
Green
White
Black
2
BK
RD
4
7
PRIMARY SIDE
YL
8
SECONDARY SIDE
Relay 12Vac 2PDT 230 Vac 10A
CR2
Relay 12Vac 2PDT 230 Vac 10A
D1
Diode NTE125002B
F1
Fuse 7 Amp AGC 250 Vac
F2
Fuse 1 Amp AGC 250 Vac
F3
Fuse 1 Amp AGC 250 Vac
T1
Transform 230V/[email protected] 50/60Hz
BK
YW/GN
BE
UP
TB 2
BE
10 11 12
RD
RD
RD
C1
YW
RD
WH
BE
BE
BE
14 AWG
Dashed wiring by Electrician
Low voltage wiring by others
YW
14 AWG
BE
14 AWG
RD
RD
1 2 3 4 5 6 7 8 9 10
RD
YW/GN
PROJECTOR OUTLET
RD
BK
CB1B
www.draperinc.com
BK
1
14 AWG
PCB 1
F2
F1
10 9 8 7 6 5 4 3 2
RD
BE
F3
BE
BE
WH
BE
WH
BE
RD
CB1A
(765) 987-7999
ALL WIRES 18 AWG. UNLESS OTHERWISE SPECIFIED.
9
9
L1
BK
YW
BE
BE
BK
8
8
N
BE
RD
RD
7
7
GND
DOWN
T1
BE
YW/GN
RD
CR 2
YW/GN
WH
6
RD
BE
RD
5
6
10
RD
BE
BK
BN
RD
4
BK
RD
BE
CR 1
SEE T1 WIRING DIAGRAM
BE
3
YW
BE
2
BE
D1
5
BK
C2
4
WH
Capacitor 100mfd 35 Vac
CR1
RD
3
GN
BK
BE
2
YL
Capacitor 2mfd +/- 370 Vac
C2
BE
1
BN
C1
MOTOR 220V .03hp 50hz. 200Lb-in. 1.1rpm
TB 1
RD
1
3 Button Wall Switch
DOWN - Black
COM - White
UP - Red
Aux Port for connecting additional Lift LVC
modules (up to six total-connect from Aux to Eye).
Eye Port for IR Eye, RF Receiver or LED
Switch. If more than one of these three is
used with one Lift LVC, a splitter is required.
T1 WIRING
VIDEO INTERFACE OR
CONTROL
220 VAC SUPPLY
50 - 60 HZ
6
BK
MOTOR
DOWN LIMIT SW
UP LIMIT SW
12 V
220 V Revelation by Draper
Page 6 of 8
Field Installation of Environmental Airspace Housing Kit
FIGURE #1
TB1
8
9
10 11 12
BE
BE
4 TURNS
14 AWG
1 2
RD
14 AWG
PROJECTOR
OUTLET
BK
WH
RD
RD
3
4 5
CS 1
YW/GN
14 AWG
BE
14 AWG
NOTES:
WIRE TO BE REMOVED BEFORE INSTALLING PLENUM WIRING
1.
WIRES CONNECTED BY INSTALLER
2.
3. ALL WIRES 18 AWG. UNLESS OTHERWISE SPECIFIED.
www.draperinc.com
12
TB2
C1
F3
PCB1
F2
F1
10
7
L1
YW/GN
PCB1
Curent sensor
F1 = 7 Ampere
F2 = 1 Ampere
F3 = 1 Ampere
F4 = 4 Ampere
F5 = 4 Ampere
Projector
Exhaust
fan
assembly
(long
wires)
Nylon tape 39" long
FIGURE #2
Inner end panel
Inner Plenum cover
Outer Plenum cover
Input
fan
assembly
Exhaust
fan
assembly
Motor
Outer end panel
1
10 9 8 7 6 5 4 3 2
F1
CR2
CB1A
6
BE
BK
220 VAC SUPPLY N
50 - 60 HZ
CB1B
RD
CR1
1
5
FAN
(OUT)
CS1
10
4
BK
FAN
(IN)
F2
BK
CB1B
3
BK
BK
1 2 3 4 5 6 7 8 9 10
2
BK
WH
1
12
1
D1
PCB 1
BK
BK RD
12 345
Input
fan
assembly
(short
wires)
F3
BK
F4
F5
T1
Wire clips typ.
DIAGRAM #1
C2
T2 transformer
T2
TB1
1
Nylon tape 43" long
1
Caution! Disconnect power from the Revelation before installing Environmental Airspace Housing.
1 Remove the covers from the electrical chassis in the Revelation.
2 Disconnect the black 14 awg. wire that runs from the T2 transformer to
the receptacle in the electrical chassis.
3 Install the pre-wired current sensor using two #6-32 x 1" [10] long screws
provided. (SEE FIGURE #1.)
4 Connect each wire of the pre-wired current sensor as shown by DIAGRAM #1.
5 Install the two fan mount assemblies [5,6] to the main pan of the Revelation using the eight #10-32 x .3/8" [7,8] long screws provided. (SEE
FIGURE #1.) Attach the long leads of the Exhaust Fan Assembly [6] to
the end with the motor and lifting mechanism.
6 Using the wire clips [11] provided, lay in the wires from the fans as
shown in FIGURE #1 and connect the fans to TB1-8 & TB1-9 as shown
in DIAGRAM #1.
7 Replace the covers to the electrical chassis.
8 Apply the 25 mm wide Nylon [12,13] tape as shown in FIGURE #1.
9 Install the inner and outer plenum covers [1,2], and attach the mating
end panel [3,4] as shown in FIGURE #2.
10 Fan mounting panels are designed to accept a standard 4" round duct.
The exhaust flange is located on the motor/drive end of the Revelation
and the input is located at projector end of the Revelation.
If duct work is connected to this unit, here are a few recommended guidelines
you should keep in mind when installing the duct work:
• Air supply to the Environmental Airspace Housing should be cool enough
to provide adequate cooling for your projector.
• Do not obstruct airflow through duct work. Inadequate airflow may result in
excessive heat buildup inside the unit.
• Keep duct work length as short as possible. Recommended maximum total
duct length is 914 cm (input plus exhaust).
• Keep the input-to-exhaust length ratio balanced and as small as possible
to prevent air from being pushed into or drawn out of the room.
CB1A
BE
BE
BE
BK
ENVIRONMENTAL AIRSPACE HOUSING
INSTALLATION PART LIST
ITEM#DESCRIPTION
1 INNER ENVIRONMENTAL AIRSPACE HOUSING COVER
2 OUTER ENVIRONMENTAL AIRSPACE HOUSING COVER
3 INNER END PANEL
4 OUTER END PANEL
5 INPUT FAN MOUNT ASSEMBLY
6 EXHAUST FAN MOUNT ASSEMBLY
7 SCREW #10–32 X .375" (9.525mm)
HEX HD TYPE "F" ZINC
8 WASHER, #10 ZINC INTERNAL LOCK
9 PRE-WIRED CURRENT SENSOR
10 SCREW #6–32 X 1" (25.4mm)
LONG PHIL PAN HD ZINC
11 CLIP ADHESIVE BACKED CORD
6.35mm HOLDING DIA.
12 991 mm LONG 25.4mm WIDE X .762mm
THICK NYLON TAPE
13 1092mm LONG 25.4mm WIDE X .762mm
THICK NYLON TAPE
TOOLS NEEDED
MED POINT PHILLIP SCREWDRIVER
1/8" FLAT BLADE SCREW DRIVER
3/8" WRENCH
(765) 987-7999
QTY
1
1
1
1
1
1
8
8
1
2
7
1
1
220 V Revelation by Draper
Page 7 of 8
Environmental Airspace Housing Operating Instructions
The Revelation Environmental Airspace Housing features a unique design
that allows easy access to virtually anywhere inside the unit. Access is
achieved by removing either end panel. End panels feature captive screw
assemblies so no hardware can be lost or misplaced. Once the end panel
is removed, slide the Environmental Airspace Housing toward the center of
the unit. Service and maintenance is made simpler due to the accessibility
provided by this unique Environmental Airspace Housing design.
Each Environmental Airspace Housing also features a ventilation system
designed to maintain a suitable operating environment for your projector. An
integrated current sensor in the Revelation circuitry turns on the fans anytime
the projector is operating and circulates fresh air through the unit. Two 4" duct
flanges are located on the ends of the Environmental Airspace Housing for
installation of duct work for directing the airflow to and from the unit. The input
flange is located on the motor/drive end of the Revelation and the exhaust
is located at projector end of the revelation. If duct work is attached to the
Revelation, follow guidelines in Environmental Airspace Housing Installation
Instructions on page 6.
Wiring Diagrams for Revelation with Environmental Airspace Housing
Single Station Control
BE
1
YL
3
5
6
BK
2
BK
RD
4
7
PRIMARY SIDE
T1 WIRING
TB 1
UP
Diode NTE125002B
F1
Fuse 7Amp AGC 250 Vac
F2
Fuse 1Amp AGC 250 Vac
F3
Fuse 1Amp AGC 250 Vac
FAN
220Vac 8Watt 50cfm 1600rpm
T1
Transform 220V/[email protected] 50/60Hz
MOTOR 220V .03hp 50-60hz. 200Lb-in. 1.1rpm
BE
CR 1
TB 2
BE
7
CR 2
8
RD
DOWN
T1
9
BE
BE
BK
10 11 12
YW
RD
RD
BE
WH
RD
RD
RD
C1
YW
BE
RD
BE
BE
14 AWG
YW
RD
RD
BE
RD
1
PCB 1
F2
CB1B
14 AWG
BE
4 TURNS
14 AWG
BK
1 2
10 9 8 7 6 5 4 3 2
YW/GN
14 AWG
PROJECTOR OUTLET
BK
BE
F3
1 2 3 4 5 6 7 8 9 10
RD
BK
BK
RD 14 AWG
F1
RD
WH
RD
RD
BE
BE
MOTOR
DOWN LIMIT SW
UP LIMIT SW
1
WIRING DONE BY INSTALLER
BK
2
BE
YW/GN
9
RD
BE
8
10
RD
BE
7
RD
YW/GN
BE
UP
SEE T1 WIRING DIAGRAM
6
BE
BE
BE
WH
BE
BE
WH
RD
CB1A
RD
3
4 5
CS 1
ALL WIRES 18 AWG. UNLESS OTHERWISE SPECIFIED.
Low Voltage Multiple Station and Remote Control
BE
1
YL
3
5
BK
2
7
8
YL
SECONDARY SIDE
T1 WIRING
BN
YL
TB 1
1
BE
CR 1
Fuse 1Amp AGC 250 Vac
F3
Fuse 1Amp AGC 250 Vac
FAN
220Vac 8Watt 50cfm 1600rpm
T1
Transform 220V/[email protected] 50/60Hz
10 11 12
YW
RD
10
WH
RD
RD
RD
C1
YW
BE
BE
BE
BE
L1
BE
14 AWG
Dashed wiring by electrician
YW
YW/GN
14 AWG
PROJECTOR OUTLET
RD
RD
BE
RD
PCB 1
F2
CB1B
14 AWG
BK
BE
4 TURNS
14 AWG
1 2
CS 1
www.draperinc.com
BK
BE
F3
1 2 3 4 5 6 7 8 9 10
RD
BK
BK
RD 14 AWG
1
Low voltage wiring by others
F1
BE
BE
BE
WH
BE
BE
RD
CB1A
RD
3
4 5
ALL WIRES 18 AWG. UNLESS OTHERWISE SPECIFIED.
(765) 987-7999
WH
YW/GN
9
BE
BK
YW/GN
RD
BK
8
DOWN
T1
BE
RD
CR 2
RD
7
RD
BE
9
N
F2
TB 2
BE
RD
BE
RD
8
GND
220 VAC SUPPLY
50 - 60 HZ
Fuse 7Amp AGC 250 Vac
WH
6
RD
7
BK
F1
YW/GN
BE
UP
SEE T1 WIRING DIAGRAM
6
FAN
(OUT)
Diode NTE125002B
RD
5
YW
BK
5
FAN
(IN)
Current sensor 230Vac 2-20Amp SASC
D1
BK
BK
BK
Relay, Coil-12Vac, 2PDT 230Vac 10Amp
CS1
RD
4
BE
D1
4
VIDEO INTERFACE
CONTROL
OR
Relay, Coil-12Vac, 2PDT 230Vac 10Amp
CR2
BE
3
C2
3
BN
Capacitor 100mfd 35 Vac
RD
2
Aux Port for connecting additional Lift LVC
modules (up to six total-connect from Aux to Eye)
BK
BE
WH
BK
Capacitor 2mfd +/- 370 Vac
C2
MOTOR 220V .03hp 50-60hz. 200Lb-in. 1.1rpm
GN
3 Button Wall Switch
DOWN - Black
COM - White
UP - Red
COMPONENT SPECIFICATIONS
C1
BE
2
Eye Port for IR Eye, RF Receiver or LED
Switch. If more than one of these three is
used with one Lift LVC, a splitter is required.
SYM
CR1
BK
RD
4
PRIMARY SIDE
RD
6
BE
1
Red
Brown
Yellow
Green
White
Black
10 9 8 7 6 5 4 3 2
L1
Current sensor 230Vac 2-20Amp SASC
D1
6
5
N
Relay, Coil-12Vac, 2PDT 230Vac 10Amp
CS1
BK
FAN
(OUT)
GND
Relay, Coil-12Vac, 2PDT 230Vac 10Amp
CR2
5
YW
BK
BK
220 VAC SUPPLY
50 - 60 HZ
Capacitor 100mfd 35 Vac
CR1
4
BE
D1
4
BK
Capacitor 2mfd +/- 370 Vac
C2
3
C2
3
BK
BK
COMPONENT SPECIFICATIONS
C1
RD
2
RD
BK
BE
1
BE
DOWN
FAN
(IN)
8
SECONDARY SIDE
WALL SWITCH
SPDT CENTER OFF
COM
YL
SYM
BK
MOTOR
DOWN LIMIT SW
UP LIMIT SW
12 V
220 V Revelation by Draper
Page 8 of 8
VIC12 Kit Installation Instructions
The VIC 12 KIT includes all the components necessary for the VIC 12 to work
with the Revelation. Follow these steps to install the components in this KIT.
1
Close the door to the Revelation.
FIGURE #1
2 DISCONNECT POWER TO THE REVELATION.
3 Remove the covers from the electrical enclosure.
CR 1
CR 2
C1
5 Run the wires through the open grommet in the end of the electrical
enclosure that is toward the motor as shown in FIGURE #1 and connect
them as follows:
Motor
Blue
Black
Pre-wired limit switch
Connect the black wire to screw #1 of TB2
Connect the blue wire to screw #2 of TB2. (Be sure that wires do not
interfere with moving linkage or the sliding inner pan)
6
Put the 12V ACTIVATOR LEVER [3] onto the shaft as shown in Figure
#2. The 12V ACTUATOR LEVER will need to be spread out before it will
fit onto the shaft. The door to the Revelation must be closed before going
on to step #7
7 Position the 12V ACTUATOR LEVER by rotating it into the limit switch
until the limit switch clicks and secure the lever onto the shaft using the
#10-32 screw [4] and lock washer [5] supplied with the lever. (Be sure
that the screw on the lever is tightened so that the lever does not twist on
the shaft.)
FIGURE #2
12V actuator lever
Rotate lever
until the limit
switch clicks.
Tighten lever
onto shaft.
8 After the VIC 12 [7] is installed with the screen, run the wiring to the
Revelation using the cord strain relief [6] and connect to TB1 as shown
in the Revelation wiring diagram.
9 Put the covers back on to the electrical enclosure.
10
TB 2
1 2 3 4 5 6 7 8 9 10
4 Attach the pre-wired limit switch [1] to the shaft mounting bracket which
is closest to the motor as shown in FIGURE #1. Using the
#6–32 x 1" [2] long screws and #6 lock washers [2] provided.
Reconnect power to the revelation.
Pre-wired
limit switch
VIC 12 OR VIC 12 MODIFIED INSTALLATION PART LIST
ITEM #
DESCRIPTION
QTY
1
PRE-WIRED LIMIT SWITCH
1
2
SCREW #6–32 X 1"(25.4mm) LONG
PHIL PAN HD W/ EXT LOCK WASHER
2
3
12v ACTUATOR LEVER
1
4
SCREW #10–32 X 3/8" (9.525mm) LONG SHCS
1
5
WASHER #10–.190" I.D. X .375" (9.525mm) O.D.
ZINC INTERNAL TOOTH
1
6
FITTING CORD CRIMP STRAIN RELIEF
1
7
VIC 12 OR VIC 12 MODIFIED
1
TOOLS NEEDED
MED POINT PHILLIP SCREW DRIVER
/8" FLAT BLADE SCREW DRIVER
I
/16" ALLEN WRENCH
3
www.draperinc.com
(765) 987-7999
12V Actuator lever