Regulus model 1373 300-1350 W with plug and switch electric heating elements Instruction manual

Regulus model 1373 300-1350 W with plug and switch electric heating elements Instruction manual

Below you will find brief information for electric heating elements model 1373 300-1350 W with plug and switch. This electric heating element is intended for heating as an accessory to towel radiators. It is installed into the radiator, where it can be heated by the electric heating element or from a heating circuit. This electric heating element is equipped with an automatic thermal reset at 90 °C, which automatically switches on again when the element cools down to 35 °C. The element is also equipped with a safety cutoff that turns it off permanently when the temperature exceeds 110 °C.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Electric heating elements model 1373 300-1350 W instruction manual | Manualzz
v. 1.0
EN
□ 300 W
□ 400 W
□ 500 W
□ 600 W
□ 700 W
□ 800 W
□ 900 W
□ 1000 W
□ 1200 W
Návod na instalaci
Owners manual
300 W
400 W
500 W
□
□
□
600 W
700 W
800 W
□ 900 W
□ 1000 W
□ 1200 W
□ 1350 W
Electric Heating Elements 300 - 1350 W with plug and switch
(model 1373 for towel radiators)
EN
□
□
□
CZ
v. 1.0
□ 1350 W
CZ
Elektrická topná tělesa 300 - 1350 W s vidlicí a s vypínačem
(model 1373 do koupelnového radiátoru)
1. Popis zařízení
Koupelnové radiátory zapojené do klasické teplovodní otopné soustavy je možné vybavit elektrickým topným tělesem. V tomto případě se těleso
instaluje přes T-kus a náplň radiátoru je ohřívána elektrickým topným tělesem, nebo pomocí stávajícího teplovodního zdroje otopné soustavy.
U koupelnových radiátorů, které nejsou součástí teplovodní otopné soustavy, se elektrické topné těleso instaluje bez T-kusu. Elektrický přívod
k elektrickému topnému tělesu se zapojí přes zásuvkový prostorový termostat, kde se nastaví požadovaná teplota ohřevu.
Koupelnové radiátory s kombinovaným způsobem vytápění lze umístit v zónách 2 a 3 (dle ČSN 33 200-7-701, vedle umyvadla, vany nebo sprchového
koutu).
Jednoduchou instalací doporučeného elektrického topného tělesa do radiátoru lze tedy získat komfortní otopný prvek.
800
735
900
835
1000
885
1200
1045
1350
1135
zone 2
700
685
zone 2
2. Obecné informace
Tento návod k použití je nedílnou a důležitou součástí výrobku a musí být předán uživateli. Pečlivě si přečtěte pokyny uvedené v tomto návodu, jelikož
obsahují důležité informace ohledně bezpečnosti, instalace, používání a údržby. Uchovejte tento návod pro případné pozdější použití.
Instalaci elektrického topného tělesa musí provést kvalifikovaná osoba v souladu s platnými předpisy a podle návodu výrobce.
Nesprávná instalace může způsobit závažná zranění lidem i zvířatům a škody na majetku. Toto zařízení je určeno pro vytápění jako doplněk ke
koupelnovým topným tělesům.
Výkon elektrického topného tělesa se volí v závislosti na tepelném výkonu radiátoru. V technických údajích každého radiátoru je uveden
maximální výkon elektrického topného tělesa.
V žádném případě se nesmí použít elektrické topné těleso o větším výkonu, než je předepsán výrobcem pro daný typ a velikost radiátoru!
Elektrické topné těleso nesmí být instalováno ve vertikální poloze s elektrickým přívodem nahoře. Pro bezpečný provoz je také nutno zajistit, aby náplň
radiátoru, která vlivem zvýšené teploty nabývá na objemu, mohla odcházet do expanzní nádoby.
Používání zařízení k jiným účelům než výše uvedeným je zakázáno a výrobce nenese žádnou odpovědnost za škodu vzniklou nevhodným nebo
špatným použitím. K vnějšímu čistění použijte nejlépe hadr namočený do přípravku vhodného k tomuto účelu. Nikdy nepoužívejte abrazivní látky, ani
rozpouštědla.
Před zahájením prací či údržby na zařízení vždy napřed odpojte přívod elektrické energie. Pokud zařízení jeví známky poruchy, vypněte ho a přivolejte
servisního pracovníka.
3. Technické údaje elektrických topných těles s vidlicí a s vypínačem
Provozní napětí: 230 V/50 Hz
Průměr závitu: G 1/2“
Těleso - krytí: IP 44 (zóna 2 nebo 3 dle ČSN 33 2000-7-701)
Vidlice s vypínačem - krytí: IP 20 (pouze zóna 3 dle ČSN 33 2000-7-701)
600
1135
585
1350
1045
500
1200
885
535
1000
835
400
900
735
435
800
685
300
700
585
395
600
535
Příkon [W]
zone 3
500
435
Montážní délka [mm]
zo
ne
0
zone 1
400
395
4. Instalace
Umístění vidlice s vypínačem
V případě použití v koupelnách nebo v místnostech s umývacími prostory je možné vidlici s vypínačem
umístit pouze do pevné zásuvky s proudovým chráničem se jmenovitým vybavovacím residuálním proudem
nepřesahujícím 30 mA, která je umístěna v zóně 3 dle ČSN 33 2000-7-701 (viz obr.).
Instalace elektrického topného tělesa do radiátoru musí být provedena v souladu s příslušnými bezpečnostními
a technickými předpisy a normami (zejména ČSN 33 2000-7-701), v souladu s doporučením výrobce
radiátoru a musí ji provést kvalifikovaná a odborně vyškolená osoba. Topné těleso musí být celou dobu
provozu ponořeno v ohřívané kapalině až po hlavici! Výkon elektrického topného tělesa se volí v závislosti
na maximálním tepelném výkonu radiátoru dle doporučení výrobce a v závislosti na jeho montážní délce.
zone 3
300
Assembly length [mm]
CZ
WEEE Registration Number:
02771/07-ECZ
Do not dispose of this product as unsorted municipal waste. Please dispose of this product by returning it to the point of sale or to your local municipal
collection point for recycling.
Respecting these rules will help to preserve, protect and improve the quality of the environment, protect human health and utilise natural resources
prudently and rationally. The crossed out wheeled bin with marking bar, printed ether in the Manual or on the product itself, identifies that the product
must be disposed of at a recycling collection site.
IMPORTANT INFORMATION ON PROPER DISPOSAL OF E-WASTE
AS REQUIRED BY THE EC DIRECTIVE 2002/96/EC (WEEE)
6. Maintenance
Once installed, this appliance requires almost no maintenance. In case the power cable suffers damage, disconnect the appliance from the mains and
contact a specialized service. It is forbidden to perform any unauthorized repairs or modifications to the heating element.
This electric heating element is equipped with an automatic thermal reset at 90 °C. When cooled down to 35 °C, the thermal cutoff switches on again
automatically. The element is also equipped with a safety cutoff that turns it off permanently when the temperature exceeds 110 °C.
5. Operation
The switch in pos. “I” – the red lamp is on and the heating element is energized.
The switch in pos. “O” – the red lamp is off and the heating element is de-energized.
When electric heating elements with a plug and switch are used together with a plug thermostat (switch in pos. “I”), the plug thermostat controls the
temperature of the electric heating element by switching on and off its power supply. Its display shows either the set or measured temperature. Plug
thermostats are recommended for this purpose.
Installation of the heating element into a radiator shall be done in compliance with the respective safety and
technical rules and standards, in accordance with recommendations of the radiator manufacturer, and shall be
done by qualified staff. During the operation, the heating element shall be immersed into the heated liquid up
to its head! The output of the electric heating element shall be selected with respect to the max. thermal output
of the radiator, as recommended by its manufacturer and depending on its assembly length.
4. Installation
Location of the plug and switch
When used in bathrooms or rooms with washing facilities, the plug with switch may be connected only to fixed sockets with an RCD having a rated
tripping current not exceeding 30 mA, located in zone 3 according to ČSN 33 2000-7-701 (see fig.).
Power input [W]
3. Technical Data
Voltage: 230 V/50 Hz
Thread diam.: G 1/2“
El. protection - body: IP 44 (zone 2 or 3 according to ČSN 33 2000-7-701)
El. protection – plug and switch: IP 20 (zone 3 only according to ČSN 33 2000-7-701)
Unplug the element before cleaning or performing maintenance. In case the appliance does not work properly, turn it off and contact your service
provider.
5. Provoz
Vypínač vidlice v poloze „I“ - červená kontrolka svítí a topné těleso je pod el. napětím.
Vypínač vidlice v poloze „O“ - červená kontrolka nesvítí a topné těleso je bez el. napětí.
Při používání elektrických topných těles s vidlicí a s vypínačem společně se zásuvkovým termostatem (vypínač vidlice v poloze „I“), zásuvkový termostat
řídí teplotu elektrického topného tělesa spínáním a rozepínáním jeho napájení. Na displeji ukazuje nastavovanou nebo měřenou teplotu. Doporučujeme
použít zásuvkové termostaty.
Elektrické topné těleso je vybaveno vratnou automatickou tepelnou pojistkou s vypínací teplotou 90 °C. Po ochlazení elektrického topného tělesa na
35 °C se automatická tepelná pojistka opět sepne bez nutnosti restartu či jiného zásahu obsluhy. Těleso je také vybaveno bezpečnostní pojistkou proti
přehřátí, která těleso trvale vypne při překročení teploty 110 °C.
6. Údržba
Zařízení nevyžaduje po instalaci v podstatě žádnou údržbu. V případě poškození přívodního kabelu k elektrickému topnému tělesu zařízení odpojte od
sítě a volejte odborný servis. Je zakázáno provádět jakékoliv neautorizované opravy nebo úpravy topného tělesa.
DŮLEŽITÉ INFORMACE O SPRÁVNÉ LIKVIDACI ZAŘÍZENÍ PODLE EVROPSKÉ SMĚRNICE 2002/96/ES
Evidenční číslo výrobce:
02771/07-ECZ
EN
Tento spotřebič nesmí být likvidován spolu s komunálním odpadem. Musí se odevzdat na sběrném místě tříděného odpadu, nebo ho lze vrátit při koupi
nového spotřebiče prodejci, který zajišťuje sběr použitých přístrojů.
Dodržováním těchto pravidel přispějete k udržení, ochraně a zlepšování životního prostředí, k ochraně zdraví a k šetrnému využívání přírodních zdrojů.
Tento symbol přeškrtnuté a podtržené popelnice v návodu nebo na výrobku znamená povinnost, že se spotřebič musí zlikvidovat odevzdáním na sběrném
místě.
11/2013
Using the appliance for other purposes than above described is forbidden and the manufacturer accepts no responsibility for damage caused by
improper or wrong use. Clean its exterior with a soft cloth and a suitable detergent. Never use abrasive cleaners or solvents.
2. General Information
This Manual is an integral and important part of the product and must be handed over to the User. Read carefully the instructions in this Manual as they
contain important information concerning safety, installation, operation and maintenance. Keep this Manual for later reference.
The appliance shall be installed by a qualified person according to valid rules and Manufacturer‘s Instructions.
Wrong installation may cause serious harm to persons and animals and also damage to property. This appliance is intended for heating as an accessory
to towel radiators.
The power output of the heating element shall be selected with respect to the heating output of the radiator. Technical data of any radiator
shall include the max. power output of an electric heating element.
In no event an electric heating element can be used of a higher output than set by the manufacturer for the given radiator type and size!
This electric heating element shall not be installed vertically with the electric cord pointing upwards. It is also essential for a safe operation that the
expanded volume of the heating liquid inside the radiator can flow into an expansion vessel when heated.
1. Description
Towel radiators in a traditional hot-water heating circuit can be equipped with an electric heating element. In such a case, the heating element shall
be installed into a T-piece. The radiator is then heated either by the electric heating element, or from a heating circuit. For isolated towel radiators
the heating element shall be installed without the T-piece. The heating element shall be wired via an electric-socket thermostat where the desired
temperature is set. Towel radiators with combined heating can be placed in zones 2 and 3 (according to ČSN 33 200-7-701, next to a washbasin,
bathtub or shower cabin).
In this way, a comfortable heating body can be obtained.

advertisement

Key Features

  • Can be installed in towel radiators
  • Heated by electric heating element or from a heating circuit
  • Automatic thermal reset at 90 °C
  • Safety cutoff at 110 °C

Frequently Answers and Questions

How do I install the electric heating element?
The electric heating element should be installed by a qualified person according to valid rules and the Manufacturer’s Instructions.
What wattage do I need?
The power output of the heating element shall be selected with respect to the heating output of the radiator. Technical data of any radiator shall include the max. power output of an electric heating element.
What happens if the element overheats?
This electric heating element is equipped with an automatic thermal reset at 90 °C, which automatically switches on again when the element cools down to 35 °C. The element is also equipped with a safety cutoff that turns it off permanently when the temperature exceeds 110 °C.