SEE COMPLETE INSTALLATION INSTRUCTIONS

SEE COMPLETE INSTALLATION INSTRUCTIONS
Installation Guide
Viking Range, LLC
111 Front Street
Greenwood, Mississippi 38930 USA
(662) 455-1200
For product information,
Professional Indoor and
Outdoor Hoods
call 1-888-(845-4641)
or visit the Viking Web site at vikingrange.com
F21287 EN
(090113)
Table of Contents
IMPORTANT—Please Read and Follow!
Warnings & Important Information________________________________________________________ 3-4
VWH 10” H./12”H. Wall Hoods w/Standard Ventilator 30”, & 36”
Dimensions & Specifications _____________________________________________________ 5
Clearance Dimensions ___________________________________________________________ 6
Interior Ventilator Dimensions ____________________________________________________ 7
VWH 18”H. 24”Deep Wall Hoods 30”, 36”, 42”, 48”, & 60”
Dimensions & Specifications ______________________________________________________ 8
Clearance Dimensions _____________________________________________________________ 9
Interior Ventilator Dimensions _____________________________________________________ 10
Exterior Ventilator Dimensions ___________________________________________________ 11
VWHO 18”H. Outdoor Wall Hoods 36”, 48”, & 60”
Dimensions & Specifications _____________________________________________________ 12
Clearance Dimensions __________________________________________________________ 13
VCWH Chimney Wall Hoods 30”, 36”, 42”, 48”, & 60”
Dimensions & Specifications _____________________________________________________ 14
Clearance Dimensions __________________________________________________________ 15
Interior Ventilator Dimensions ___________________________________________________ 16
Exterior Ventilator Dimensions ___________________________________________________ 17
VCIH Chimney Island Hoods 36”, 42”, 54”, & 66”
Dimensions & Specifications _____________________________________________________ 18
Clearance Dimensions ___________________________________________________________ 19
Interior Ventilator Dimensions ___________________________________________________ 20
Exterior Ventilator Dimensions ___________________________________________________ 21
VBCV Wall Custom Ventilator System
Dimensions & Specifications _____________________________________________________ 22
Installing Hood Canopy _________________________________________________________ 23
Clearance Dimensions ___________________________________________________________ 24
VBCV Ventilator Dimensions _____________________________________________________ 25
Planning Information________________________________________________________________ 27
Installation Procedures
Installation (VWH 12”H. Wall Hoods w/Standard Ventilator) __________________________ 28
Duct Cover Option (VWH 12”H. Wall Hoods w/Standard Ventilator)___________________ 30
Installation (VWH 12”H. Wall Hoods w/Recirculating Kit) _____________________________ 30
Installation (VWH 18”H. Wall & VCWH Chimney Wall Hoods) ________________________ 33
Duct Cover Option (VWH 18”H. Wall Hoods)_______________________________________ 34
Duct Cover Option (VCWH Chimney Wall Hoods) __________________________________ 35
Installation (VCIH Island Hoods) __________________________________________________ 36
Service & Registration_______________________________________________________________ 38
Wiring Diagram ____________________________________________________________________ 39
2
NOTE: If installing hood with warming shelf panel, install
warming shelf panel first.
WARNING
To reduce the risk of fire, electric shock, or injury
to persons, observe the following:
IMPORTANT – PLEASE READ AND FOLLOW
• Before beginning, please read these instructions completely and
carefully.
• Do not remove permanently affixed labels, warnings, or plates
from the product. This may void the warranty.
• Please observe all local and national codes and ordinances. If no
local codes are applicable, wire in accordance with the National
Electrical Code, ANSI/NFPA 70-latest edition.
• Damp environment approved models should be installed in a
covered non-enclosed area and should be protected from the
elements as much as possible.
• The installer should leave these instructions with the consumer
who should retain for local inspector’s use and for future
reference.
• Check with a qualified and trained installer or local codes for
makeup air requirement, if any.
• Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact
the manufacturer.
• Before servicing or cleaning unit, switch power off
at service panel and lock service panel to prevent
power from being switched on accidentally. When
the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such
as a tag, to the service panel.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRICAL
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
1. Installation work and electrical wiring must be
done by qualified person(s) in accordance with
all applicable codes and standards, including
fire-rated construction.
2. Sufficient air is needed for proper combustion
and exhausting of gases through the flute
(chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment
manufacturer’s guideline and safety standards
such as those published by the National Fire
Protection Association (NFPA), and the
American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the
local code authorities.
3. When cutting of drilling into wall or ceiling, do
not damage electrical wiring and other hidden
utilities.
4. Ducted fans must always be vented to the outdoors.
5. WARNING!: To reduce risk of fire, use only
metal ductwork
6. CAUTION!: To reduce risk of fire and to
properly exhaust air, be sure to duct air outside.
Do not vent exhaust air into spaces within walls
or ceilings, or into attics, crawl spaces, or
garages.
7. CAUTION!: To Reduce the Risk of Fire and
Electric Shock, Install this rangehood only with
remote blower models manufactured by Viking,
model numbers – DEV900/DEV1200,
VEV900/VEV1200, OR DEV1500, VEV1500 or
integral blowers manufactured by Viking, model
numbers – DIV300, DIV440, DIV600, DIV800,
DIV1200, VIV300, VIV600, or VIV1200. NOTE –
Please refer inside for specific canopy/blower
combinations.
This hood is for residential installation only and is not designed for
installation over a commercial product. Make sure power is off at
the main circuit breaker or fuse box before making connections. To
avoid risk of fire, electric shock, or injury to persons, turn off the
electricity to the hood from the power supply before servicing or
cleaning. Viking hoods are equipped with variable speed control
blowers. These units will not function with a single speed
ventilator. All Viking Range ventilator kits are designed specifically
for use with Viking Range hoods. Use of any non-Viking Range
ventilator kit will void the hood warranty.
Viking hoods are equipped with the variable speed controls for
blowers. These units will not function with a single speed
ventilator. All Viking ventilator kits are designed specifically for use
with Viking hoods. Use of any non-Viking ventilator kit will void the
hood warranty.
READ AND SAVE THESE INSTRUCTIONS
3
IMPORTANT—Please Read and Follow!
Dimensions & Specifications
(VWH 10” H./12”H. Wall Hoods w/Standard Ventilator 30”, & 36”)
CAUTION
WARNING
For general ventilating use only. Do not use to
exhaust hazardous or explosive materials and
vapors.
To reduce the risk of injury to persons in the
event of a rangetop grease fire, observe the
following. (Based on “Kitchen Firesafety Tips,”
published by NFPA.)
1
(30 2 ”
.5
cm
)
1. SMOTHER FLAMES with a close fitted lid, cookie
sheet, or metal tray, then turn off the burner. BE
CAREFUL TO PREVENT BURNS. If the flames do
not go out immediately, EVACUATE AND CALL
THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN. You may be
burned.
3. DO NOT USE WATER, including wet dishcloths or
towels a violent steam explosion will result.
4. Use an extinguisher ONLY if
• You know it is a Class ABC extinguisher, and you
already know how to operate it.
• The fire is small and contained in the area where
it started.
• The fire department is being called.
• You can fight the fire with your back to an exit.
(2510”
.4
c
(12 5”
.7
cm
m)
)
WARNING
TO REDUCE THE RISK OF FIRE,
ELECTRICAL SHOCK, OR INJURY
TO PERSONS
Rangehoods must be installed with
the ventilators that are specified on
their carton indicating suitability with
this model. Other ventilators cannot be substituted.
A
”
21 cm)
(53
.3
1
30”W.
36”W.
A (Hood width)
29-7/8“ (76.2 cm)
35-7/8” (91.1 cm)
(30 2 ”
.5
cm
)
1
(12 5”
.7
cm
(30 2 ”
.5
cm
)
)
”
21 cm)
A
30”W.
36”W.
.3
(53
A (Hood width)
29-7/8“ (76.2 cm)
35-7/8” (91.1 cm)
NOTE: Optional duct cover sold separately.
VWH 10’ H./12”H. Wall Hoods w/Standard Ventilator
Description
Duct cover width
30”
36”
29-7/8” (75.9 cm)
35-7/8” (91.1 cm)
Duct cover depth
12” (30.5 cm)
Duct cover height
12” (30.5 cm)
2
Number of filters
N/A
Heat lamps
460 CFM Standard
Interior ventilator kit
7” (17.8 cm)
Interior duct size*
4.9
Interior—Maximum amps
* Disregard when using recirculating kits.
460 CFM blower is shipped with hood. Max duct run is 50 ft (15.2 m)
4
5
Clearance Dimensions
Interior Ventilator Dimensions
(VWH 10” H./12”H. Wall Hoods w/Standard Ventilator)
(VWH 10” H./12”H. Wall Hoods w/Standard Ventilator)
Top View
24”W.
30”W.
36”W.
60
(15 ”m
i
24
(61”mi
.0 n.
c
27 t o m)
”
(68 max
.6 .*
cm
)
2.4 n.
c
63 to m)
”
(16 ma
0.0 x.
cm
)
”
36 m)
c
.4
(91
A
23-7/8” (60.6 cm)
29-7/8” (75.9 cm)
35-7/8” (91.1 cm)
24”W.
30”W.
36”W.
B
5-1/4” (13.3 cm)
8-1/4” (20.9 cm)
11-1/4” (28.6 cm)
24”W.
30”W.
36”W.
C
11-15/16” (30.3 cm)
14-15/16” (37.9 cm)
17-15/16” (45.6 cm)
24”W.
30”W.
36”W.
D
5/8” (1.6 cm)
3-5/8” (9.2 cm)
6-5/8” (16.8 cm)
A
18”
(4.6 cm)
B
D
3-4”
(1.9 cm)
C
4”
(10.2 cm)
3-7/8”
(9.8 cm)
7” (17.8 cm) dia.
duct location
460 CFM Interior Ventilator Installation
* NOTE: When installing with a 24” high-shelf,
the 27” (68.6 cm) max. dimensions must be used.
6
7
1/2”
(1.3 cm)
3-1/2”
(8.9 cm)
Electrical
hookup
Dimensions & Specifications
Clearance Dimensions
(VWH 18”H. 24” Deep Wall Hoods 30”, 36”, 42”, 48”, & 60”)
(VWH 18”H. Wall Hoods)
30”W.
36”W.
42”W.
48“W.
60”W.
A (Hood width)
29-7/8“ (76.2 cm)
35-7/8” (91.1 cm)
41-7/8” (106.4 cm)
47-7/8” (121.6 cm)
59-7/8” (152.1 cm)
(3012”
.5
cm
)
(15 6”
.2
cm
)
(4518”
.7
cm
)
A
”
24 cm)
.0
(61
66
(16 ”m
7.6 in.
c
72 to m)
”
(18 ma
2.9 x.
cm
)
NOTE: Optional duct cover sold separately.
VWH 18”H. Wall Hoods
Description
Duct cover width
30”
36”
42”
48”
60”
29-7/8”
(75.9 cm)
35-7/8”
(91.1 cm)
41-7/8”
(106.4 cm)
47-7/8”
(121.6 cm)
59-7/8”
(152.1 cm)
Duct cover depth
12” (30.5 cm)
Duct cover height
12” (30.5 cm)
Number of filters
2
2
2
3
4
1
1
1
2
3
VINV300/
600/1200
DEV900/
1200*
DIL1200
VINV300/
600/1200
DEV900/
1200*
DIL1200
VINV600/
1200
DEV900/
1200*
DIL1200
VINV1200*
VINV1200*
DEV1200*/
1500**
DIL1200
DEV1200*/
1500**
DIL1200
7”/10”
(17.8/25.4 cm)
7”/10”
(17.8/25.4 cm)
7”/10”
(17.8/25.4 cm)
10”
(25.4 cm)
10”
(25.4 cm)
Interior—Maximum amps
4.2/5.2/8.2
4.2/5.2/8.2
5.2/8.2
10.8
10.8
Exterior—Maximum amps
8.0/5.3
8.0/5.3
8.0/5.3
7.8/8.5
7.8/8.5
In-Line—Maximum amps
5.3/7.2
5.3/7.2
5.3/7.2
9.6
10.0
Heat lamps
Interior ventilator kits
Exterior ventilator kits
In-line ventilator kits
Interior duct size
30
”
(76 mi
.2 n.
c
36 to m)
”
(91 ma
.4 x.
cm
)
”
36 cm)
.4
(91
10” (24.5 cm)
Exterior duct size
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas chargrill. Max duct run is 50 ft (15.2 m).
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft (22.9 m)
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
8
9
Interior Ventilator Dimensions
Exterior Ventilator Dimensions
(VWH 18”H. Wall Hoods)
(VWH 18”H. Wall Hoods)
Top View
Top View
A
A
30”W.
36”W.
42”W.
48”W.
60”W.
A
14-15/16” (37.9 cm)
17-15/16” (45.6 cm)
20-15/16” (53.2 cm)
23-15/16” (60.8 cm)
29-15/16” (76.0 cm)
30”W.
36”W.
42”W.
48”W.
60”W.
4-5/8”
(11.7 cm)
B
29-7/8” (75.9 cm)
35-7/8” (91.1 cm)
41-7/8” (106.4 cm)
47-7/8” (121.6 cm)
59-7/8” (152.1 cm)
30”W.
36”W.
42”W.
48”W.
60”W.
A
14-15/16” (37.9 cm)
17-15/16” (45.6 cm)
20-15/16” (53.2 cm)
23-15/16” (60.8 cm)
29-15/16” (76.0 cm)
30”W.
36”W.
42”W.
48”W.
60”W.
5-15/16”
(15.1 cm)
10” (25.4 cm)
dia. duct location
7”(17.8 cm)
dia. duct location
B
B
300 or 600 CFM Interior Ventilator Installation for all Wall Hoods
900 or 1200 CFM Exterior or In-Line Ventilator Installation for all
Wall Hoods
Top View
Top View
A
A
30”W.
36”W.
42”W.
48”W.
60”W.
A
14-15/16” (37.9 cm)
17-15/16” (45.6 cm)
20-15/16” (53.2 cm)
23-15/16” (60.8 cm)
29-15/16” (76.0 cm)
30”W.
36”W.
42”W.
48”W.
60”W.
5-1/2”
(14.0 cm)
B
29-7/8” (75.9 cm)
35-7/8” (91.1 cm)
41-7/8” (106.4 cm)
47-7/8” (121.6 cm)
59-7/8” (152.1 cm)
B
29-7/8” (75.9 cm)
35-7/8” (91.1 cm)
41-7/8” (106.4 cm)
47-7/8” (121.6 cm)
59-7/8” (152.1 cm)
10” (25.4 cm)
dia. duct location
30”W.
36”W.
42”W.
48”W.
60”W.
A
14-15/16” (37.9 cm)
17-15/16” (45.6 cm)
20-15/16” (53.2 cm)
23-15/16” (60.8 cm)
29-15/16” (76.0 cm)
30”W.
36”W.
42”W.
48”W.
60”W.
5-15/16”
(15.1 cm)
B
29-7/8” (75.9 cm)
35-7/8” (91.1 cm)
41-7/8” (106.4 cm)
47-7/8” (121.6 cm)
59-7/8” (152.1 cm)
10” (25.4 cm)
dia. duct location
B
B
1200 CFM Interior Ventilator Installation for all Wall Hoods
1200 or 1500 CFM Exterior or In-Line Ventilator Installation for all
Wall Hoods
10
11
Dimensions & Specifications
Clearance Dimensions
(VWHO 18”H. Outdoor Wall Hoods 36”, 48”, & 60”)
(VWHO 18”H. Outdoor Wall Hoods)
Seal joints with silicone.
Provided on “T” Series only.
”
18 )
1
(30 2”
.5
cm
)
.7
(45
cm
”
“X
M /2”
I
D 4-1 m)
+ c
.4
(11
(15 6”
.2
cm
)
36”W.
48“W.
60”W.
1
(45 8”
.7
cm
)
”
27 cm)
.6
(68
66
A (Hood width)
35-7/8” (91.1 cm)
47-7/8” (121.6 cm)
59-7/8” (152.1 cm)
(16” m
7.6 in.
c
72 to m)
(18” m
2.9 ax.
cm
)
”
27 cm)
A
.6
(68
30
(76 ”mi
. 2 n.
c
36 to m)
”m
(91 a
.4 x.
cm
)
NOTE: Optional duct cover sold separately.
”
36 cm)
VWHO 18”H. Outdoor Wall Hoods
Description
Duct cover width
.4
36”
48”
60”
35-7/8” (91.1 cm)
47-7/8” (121.6 cm)
59-7/8” (152.1 cm)
Duct cover depth
12” (30.5 cm)
Duct cover height
12” (30.5 cm)
2
3
4
Interior ventilator kits
VINV1200*
VINV1200*
VINV1200*
Exterior ventilator kits
DEV1200*/1500**
DEV1200*/1500**
DEV1200*/1500**
DIL1200
DIL1200
Number of filters
In-line ventilator kits
DIL1200
Interior duct size
10” (25.4 cm)
Exterior duct size
10” (25.4 cm)
Interior—Maximum amps
9.0
11.4
11.8
Exterior—Maximum amps
6.1/6.8
8.4/9.1
8.8/9.5
In-Line—Maximum amps
7.9
10.2
10.6
* A 1,200 CFM interior- or exterior-power ventilator should be used with all outdoor models and when indoor models
are installed over range/rangetop with gas char-grill. Max duct run is 50 ft (15.2 m).
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft (22.9 m).
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
12
(91
Note: Outdoor Models must be installed in a covered, non-enclosed area, and should be protected from
the elements as much as possible.
The bottom of the hood should be 30” (76.2 cm) to 36” (91.4 cm) above the grill surface. The hood
should be installed 4-1/2” (11.4 cm) plus the distance between the back trim and surface from the
back wall. (Note: There is a 3” minimum clearance from the back trim to non-combustible surfaces,
and a 24” minimum to combustible surfaces.) This will require building the hood out from the wall.
Any combustible material used for this purpose must be covered with locally-supplied stainless
steel. Viking also recommends using a backsplash.
13
Dimensions & Specifications
Clearance Dimensions
(VCWH Chimney Wall Hoods 30”, 36”, 42”, 48”, 54”, & 60”)
(VCWH Chimney Wall Hoods)
A
30”W.
36”W.
42”W.
48“W.
60”W.
66”W.
A (Duct width)
12“ (30.5 cm)
12“ (30.5 cm)
12“ (30.5 cm)
18“ (45.7 cm)
24“ (61.0 cm)
24“ (61.0 cm)
B (Hood width)
30”W.
29-7/8“ (76.2 cm)
36”W.
35-7/8” (91.1 cm)
42”W.
41-7/8” (106.4 cm)
48“W.
47-7/8” (121.6 cm)
60”W.
59-7/8” (152.1 cm)
66”W.
65-7/8” (167.3 cm)
(3012”
.5
c
to m)
2
(61 4”
.0
cm
)
(15 6”
.2
cm
)
(4518”
.7
cm
)
”
24 cm)
B
66
.0
(61
(16 ”m
7.6 in.
c
72 to m)
”
(18 ma
2.9 x.
cm
)
NOTE: Optional duct cover sold separately.
VCWH Chimney Wall Hoods
Description
30”
36”
42”
48”
12” (30.5 cm) 12” (30.5 cm) 12” (30.5 cm) 18” (45.7 cm) 24” (61.0 cm)
Duct cover depth
12” (30.5 cm)
Duct cover height
12” (30.5 cm) to 24” (61.0 cm)
Heat lamps
Interior ventilator kits
2
2
1
1
VINV300/600 VINV300/600
.4
2
2
3
1
VINV600
2
VINV1200*
3
VINV1200*
DEV1200*/
1500**
DIL1200
DEV1200*/
1500**
DIL1200
DEV900/
1200*
DIL1200
DEV900/
1200*
DIL1200
7” (17.8 cm)
7” (17.8 cm)
7” (17.8 cm)
Interior—Maximum amps
4.2/5.2
4.2/5.2
10” (25.4 cm)
5.2
10.8
10.8
Exterior—Maximum amps
8.0/5.3
8.0/5.3
8.0/5.3
7.8/8.5
7.8/8.5
In-Line—Maximum amps
5.3/7.2
5.3/7.2
5.3/7.2
9.6
10.0
In-line ventilator kits
Interior duct size
Exterior duct size
”
36 cm)
(91
DEV900/
1200*
DIL1200
Exterior ventilator kits
(76 mi
.2 n.
c
36 to m)
”
(91 ma
.4 x.
cm
)
60”
Duct cover width
Number of filters
30
”
10” (25.4 cm) 10” (25.4 cm)
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas chargrill. Max duct run is 50 ft (15.2 m).
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft (22.9 m).
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-wire
with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
14
15
Interior Ventilator Dimensions
Exterior Ventilator Dimensions
(VCWH Chimney Wall HoodsF
(VCWH Chimney Wall HoodsF
Top View
12”
(30.5 cm)
Top View
120V
power
supply
1-1/2”
(3.8 cm)
12”
(30.5 cm)
A
A
30”W.
36”W.
42”W.
A
14-15/16” (37.9 cm)
17-15/16” (45.6 cm)
20-15/16” (53.2 cm)
30”W.
36”W.
42”W.
B
29-7/8” (75.9 cm)
35-7/8” (91.1 cm)
41-7/8” (106.4 cm)
8”
(20.3 cm)
1-1/2”
(3.8 cm)
120V
power
supply
1-1/2”
(3.8 cm)
7” (17.8 cm) dia.
duct location
30”W.
36”W.
42”W.
A
14-15/16” (37.9 cm)
17-15/16” (45.6 cm)
20-15/16” (53.2 cm)
30”W.
36”W.
42”W.
B
29-7/8” (75.9 cm)
35-7/8” (91.1 cm)
41-7/8” (106.4 cm)
8”
(20.3 cm)
1-1/2”
(3.8 cm)
10” (25.4 cm) dia.
duct location
B
B
300 or 600 CFM Interior Ventilator Installation
for 30”, 36”, & 42” models
900 or 1200 CFM Exterior or In-Line Ventilator Installation
for 30”, 36”, & 42” models
Top View
Top View
C
1-1/2”
(3.8 cm)
120 V
power
supply
C
A
23-15/16” (60.8 cm)
29-15/16” (76.0 cm)
32-15/16” (83.7 cm)
48”W.
60”W.
66”W.
B
47-7/8” (121.6 cm)
59-7/8” (152.1 cm)
65-7/8” (167.3 cm)
6”
(15.2 cm)
1-1/2”
(3.8 cm)
120 V
power
supply
A
A
48”W.
60”W.
66”W.
1-1/2”
(3.8 cm)
48”W.
60”W.
66”W.
10” (25.4 cm) dia.
duct location
C
18” (45.7 cm)
24” (61.0 cm)
24” (61.0 cm)
48”W.
60”W.
66”W.
A
23-15/16” (60.8 cm)
29-15/16” (76.0 cm)
32-15/16” (83.7 cm)
48”W.
60”W.
66”W.
B
47-7/8” (121.6 cm)
59-7/8” (152.1 cm)
65-7/8” (167.3 cm)
6”
(15.2 cm)
1-1/2”
(3.8 cm)
48”W.
60”W.
66”W.
C
18” (45.7 cm)
24” (61.0 cm)
24” (61.0 cm)
10” (25.4 cm) dia.
duct location
B
B
1200 CFM Interior Ventilator Installation
for 48”, & 60”models
900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation
for 48”, & 60”models
16
17
Dimensions & Specifications
Clearance Dimensions
(VCIH Chimney Island Hoods 36”, 42”, 54”, & 66”)
(VCIH Chimney Island Hoods)
A
36”W.
42”W.
54”W.
66”W.
A (Duct width)
12” (30.5 cm)
12” (30.5 cm)
18” (45.7 cm)
24” (70.0 cm)
36”W.
42”W.
54”W.
66”W.
B (Duct height)
12” (30.5 cm)
or
24” (61.0 cm)
or
36” (91.4 cm)
36”W.
42”W.
54”W.
66”W.
C (Hood width)
35-7/8” (91.1 cm)
41-7/8” (106.4 cm)
53-7/8” (136.8 cm)
65-7/8” (167.3 cm)
(15 6“
.2
cm
B
)
1
(45 8”
.7
cm
)
”
30 cm)
C
66
.2
(76
(16 ”m
7.6 in.
c
72 to m)
”
(18 ma
2.9 x.
cm
)
NOTE: Optional duct cover sold separately.
VCIH Chimney Island Hoods
Description
Duct cover width
36”
42”
54”
66”
12” (30.5 cm)
12” (30.5 cm)
18” (45.7 cm)
24” (70.0 cm)
12” (30.5 cm)
Duct cover depth
4
4
6
8
Interior ventilator kits
VINV600
VINV600
Exterior ventilator kits
DEV900/1200*
VINV1200*
VINV1200*
DEV900/1200*/1500**
DEV1200*/1500**
DEV1200*/1500**
DIL1200
DIL1200
DIL1200
DIL1200
7” (17.8 cm)
7” (17.8 cm)
10” (25.4 cm)
10” (25.4 cm)
Interior—Maximum amps
4.2/5.2/8.2
5.2/8.2
8.9
9.3
Exterior—Maximum amps
7.4/4.7
7.4/4.7/5.5
5.6/6.4
6.4/7.4
In-Line—Maximum amps
4.7/6.5
3.9/5.7
7.4
7.4
Interior duct size
”
36 cm)
.4
(91
N/A
Heat lamps
In-line ventilator kits
(76”mi
.2 n.
c
36 to m)
(91”ma
.4 x.
cm
)
12” (30.5 cm) or 24” (61.0 cm) or 36” (91.4 cm)
Duct cover height
Number of filters
30
10” (25.4 cm)
Exterior duct size
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas chargrill. Max duct run is 50 ft (15.2 m).
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft (22.9 m).
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-wire
with ground. An interior or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
18
19
Interior Ventilator Dimensions
Exterior Ventilator Dimensions
(VCIH Chimney Island HoodsF
(VCIH Chimney Island HoodsF
Top View
Top View
12”
(30.5 cm)
36”W.
42”W.
A
17-15/16” (45.6 cm)
20-15/16” (53.2 cm)
36”W.
42”W.
B
35-7/8” (91.1 cm)
41-7/8” (106.4 cm)
1-1/8”
(2.9 cm)
12”
(30.5 cm)
120 V
power
supply
A
36”W.
42”W.
A
17-15/16” (45.6 cm)
20-15/16” (53.2 cm)
36”W.
42”W.
B
35-7/8” (91.1 cm)
41-7/8” (106.4 cm)
1-1/8”
(2.9 cm)
6”
(15.2 cm)
1-1/8”
(2.9 cm)
120 V
power
supply
A
1-1/8”
(2.9 cm)
6”
(15.2 cm)
7” (17.8 cm) dia.
duct location
10” (25.4 cm) dia.
duct location
B
B
600 CFM Interior Ventilator Installation
for all Chimney Island Hoods
900 or 1200 CFM Exterior or In-Line Ventilator Installation
for all Chimney Island Hoods
Top View
Top View
C
54”W.
66”W.
A
26-15/16” (68.4 cm)
32-15/16” (83.7 cm)
54”W.
66”W.
B
53-7/8” (136.8 cm)
65-7/8” (167.3 cm)
54”W.
66”W.
C
18” (45.7 cm)
24” (61.0 cm)
1-1/8”
(2.9 cm)
A
120 V
power
supply
1-1/8”
(2.9 cm)
6”
(15.2 cm)
10” (25.4 cm) dia.
duct location
B
C
54”W.
66”W.
A
26-15/16” (68.4 cm)
32-15/16” (83.7 cm)
54”W.
66”W.
B
53-7/8” (136.8 cm)
65-7/8” (167.3 cm)
54”W.
66”W.
C
18” (45.7 cm)
24” (61.0 cm)
1-1/8”
(2.9 cm)
A
120 V
power
supply
1-1/8”
(2.9 cm)
6”
(15.2 cm)
10” (25.4 cm) dia.
duct location
B
1200 CFM Interior Ventilator Installation
for all Chimney Island Hoods
900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation
for all Chimney Island Hoods
20
21
Dimensions & Specifications
Installing Hood Canopy
(VBCV Wall Custom Ventilator System 36”, 42”, 48”, & 60”)
(Custom Hood Canopy CutoutsF
A*
*For best results,
center the unit over
the burners of the
cooking product
(front to back; right
to left).
Make sure the back wall
of the custom hood
canopy is flush with the
cutout so the ventilator
system may be mounted
as shown on page 25.
B*
Custom Hood
Canopy
A
B
Bottom Cutout Dimensions
Wall Hoods
Description
36”
42”
48”
60”
W.
W.
W.
W.
A (Hood Width)
B (Hood Depth)
33-7/16” (84.9 cm)
39-7/16” (100.2 cm)
45-7/16” (115.4 cm)
57-7/16” (145.9 cm)
21-7/16”
21-7/16”
21-7/16”
21-7/16”
(54.5
(54.5
(54.5
(54.5
cm)
cm)
cm)
cm)
VBCV Wall Custom Ventilator System
Description
36”
42”
48”
60”
Number of filters
2
2
3
4
Heat lamps
1
1
2
3
Interior ventilator kits
Exterior ventilator kits
In-line ventilator kits
Interior duct size
VINV300/
600/1200*
DEV900/
1200*
DIL1200
VINV600/ VINV1200* VINV1200*
1200*
DEV900/
DEV1200*/ DEV1200*/
1200*
1500**
1500**
DIL900/1200
DIL1200
DIL1200
7”/10”
7”/10”
10”
(17.8/25.4 cm) (17.8/25.4 cm) (25.4 cm)
1) Position ventilator
system inside of the
custom hood canopy
and center it front to
back and left to right.
Built-In Ventilator
System
2) Bottom mounting holes
fasten ventilator system
to bottom of custom
hood canopy with the
screws provided.
10”
(25.4 cm)
3) OPTIONAL
Rear mounting holes fasten
ventilator system to rear of
custom hood canopy.
10” (25.4
Exterior duct size
Interior—Maximum amps
4.2/5.2
10.8
10.8
10.8
Exterior—Maximum amps
8.0/5.3
8.0/5.3
7.8/8.5
7.8/8.5
In-Line—Maximum amps
5.3/7.2
5.3/7.2
9.6
10.0
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas chargrill. Max duct run is 50 ft (15.2 m).
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft (22.9 m).
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
22
23
Built-In Wall Custom Ventilator
System Dimensions (VBCV ModelsF
Clearance Dimensions
(VBCV Wall Custom Ventilator System)
1-1/2”
(3.8 cm)
1”
(2.54 cm)
1-1/2”
(3.81 cm)
7/8”
(2.2 cm)
(Cu
sto
m
11-1/2”
(29.2 cm)
Ho
od
)
17-1/4”
(43.8 cm)
6”
(15.2 cm)
5/8”
(1.6 cm)
66
5/8”
(1.6 cm)
21-7/8”
(55.8 cm)
21-7/8”
(55.8 cm)
(16 ”m
7.6 in.
c
72 t o m )
”
(18 ma
2.9 x.
cm
)
30
(7 ”m
6.2 in.
c
36 to m)
”
(91 ma
.4 x.
cm
)
For 300, 600 or 1200 CFM Interior
Ventilator Installation
For 900, 1200 or 1500 CFM Exterior
or In-Line Ventilator Installation
D
D
”
36 cm)
.4
(91
4-5/8”
(11.7 cm)
5-1/2”
(14.0 cm)
7” (17.8 cm)
dia. duct location
10” (25.4 cm)
dia. duct location
5/8” (1.6 cm)
5/8” (1.6 cm)
C
C
300 or 600 CFM Interior
Ventilator Installation
36”, 42” W. Models
900 or 1200 CFM Exterior
or In-Line Ventilator Installation
36”, 42” W. Models
D
C
36” W.
42” W.
24
36” W.
42” W.
34-1/4” (87.0 cm)
40-1/4” (102.2 cm)
25
17-1/8” (43.5 cm)
20-1/8” (51.1 cm)
Built-In Wall Custom Ventilator
System Dimensions (VBCV ModelsF
D
5-1/2”
(14.0 cm)
10” (25.4 cm)
dia. duct location
5/8” (1.6 cm)
C
1200 or 1500 CFM Exterior or In-Line Ventilator Installation
48”, 60” W. Models
Planning Information
Proper installation of ducting is extremely
important to ensure maximum performance
from any ventilation product.
• All CFMs are based on tests at 0.1 static
pressure: without applying static pressure, CFM
would be greatly overstated.
• Straight runs and gradual turns are best; for
example, each 90º elbow is equivalent to 5-10
feet (1.52-3.05 cm) of straight run.
• Never use flexible duct; it creates back pressure/air
turbulence and greatly reduces performance.
• Proper performance is dependent on proper
ducting; make sure that a qualified and trained
installer is used.
• Check with a qualified and trained installer or
local codes for makeup air requirement, if any.
• Max. amp rating for hoods includes
recommended ventilator kit rating; all products
must be hard wired direct with 2-wire with ground.
Roof cap
7” round duct
Duct cover or soffit
Hood
Roof cap
10” round duct
5-1/2”
(14.0 cm)
1200 CFM
single blower
interior power
typical ductwork
Duct cover or soffit
Plan where the duct work will be located. Install
proper-sized duct work, and roof or wall cap for the
type of blower you are using. Recommended hood
locations for the most common installations are
shown. Adjust your measurements for various heights
of ceilings, soffits, cabinets, or ranges/rangetops.
D
300 or 600 CFM
single blower
interior-power
typical ductwork
Hood
Exterior blower
10” round duct
900, 1200, or
1500 CFM
exterior power
typical ductwork
Check Framing
Duct cover or soffit
10” (25.4 cm)
dia. duct location
5/8” (1.6 cm)
Hood
C
1200 CFM Interior Ventilator Installation
36”, 42”, 48”, 60” W. Models
Wall cap
Duct
C
36”
42”
48”
60”
W.
W.
W.
W.
Wall Installation
exterior power
typical ductwork
Duct cover or soffit
D
34-1/4” (87.0 cm)
40-1/4” (102.2 cm)
46-1/4” (117.5 cm)
58-1/4” (148.0 cm)
36”
42”
48”
60”
26
W.
W.
W.
W.
17-1/8” (43.5 cm)
20-1/8” (51.1 cm)
23-1/8” (58.7 cm)
29-1/8” (74.0 cm)
Hood
NOTE: Because of the weight of the hood make sure
that the mounting screws are driven into the framing
and not just the drywall. It may be necessary to drill
additional holes in the canopy for proper alignment.
NOTE: Wall exhaust must be a minimum of 24” (61.0 cm)
from ground. This may vary depending on local codes
and geographic location.
27
Installation (VWH 10” H./12”H. Wall Hoods w/Standard Ventilator)
6
2
1
5/16”
nut driver
5/16”
nut driver
Check damper for unrestricted movement, adjust if
necessary.
Attach transition to damper. Seal with aluminum tape.
WARNING
3
CAUTION: If not using a duct cover, using screws
provided, make sure top mounting screws are secured
into soffit or cabinet framing. Use additional mounting
screws, if necessary.
CAUTION: Secure vent hood to wall using screws
provided. Use additional mounting screws and wall
anchors, if necessary.
7
8
BARE OR GREEN
To reduce the risk of fire, electric shock, or injury
to persons, observe the following:
1
1
• Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact
the manufacturer.
• Before servicing or cleaning unit, switch power off
at service panel and lock service panel to prevent
power from being switched on accidentally. When
the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such
as a tag, to the service panel.
WHITE
BLACK
WHITE
Connect black to black, white to white, and the
green/bare wire under the green screw.
NOTE: Housing wiring must be properly installed for
wiring to be correct when wiring unit.
Flip hood over and remove electrical box cover.
5
4
1
2
GREEN
BLACK
Replace electrical box cover. Make connection to
breaker box.
10
9
2
1
1
1
1
3
3
2
Insert 6” of electrical wiring through the top of vent hood
and secure using wiring restrain. Refer to local codes.
Slide duct over transition and tape around joint.
28
2
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
29
Duct Cover Option
Installation
(VWH 10” H./12”H. Wall Hoods w/Standard Ventilator)
(VWH 10” H./12”H. Wall Hoods w/Recirculating Kit)
3
1
2
4
2
Attach with screws and lock washers provided.
Measure distance from ceiling to canopy.
Slide the duct cover in place and fasten from inside
canopy using the sheet metal screws provided.
Attach with screws.
WARNING
5
To reduce the risk of fire, electric shock, or injury
to persons, observe the following:
• Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact
the manufacturer.
• Before servicing or cleaning unit, switch power off
at service panel and lock service panel to prevent
power from being switched on accidentally. When
the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such
as a tag, to the service panel.
Installation
Remove electrical box cover.
(VWH 12”H. Wall Hoods w/Recirculating Kit)
1
2
6
7
1
5/16”
nut driver
2
Remove damper and discard with transition.
Turn recirculating unit upside down. Place vent hood
upside down on recirculating unit.
30
Flip hood over. Insert 6” of electrical wiring through the
top of vent hood and secure. Refer to local codes.
CAUTION: Secure vent hood. Make sure mounting
screws are secured into framing. Use additional
mounting screws and wall anchors, if necessary.
31
Installation
Installation
(con’t)
(VWH 10” H./12”H. Wall Hoods w/Recirculating Kit)
8
(VWH 18”H. Wall & VCWH Chimney Wall Hoods)
9
BARE OR GREEN
1
1
1-1/2”x 3/4”
(3.8 cm) x (1.9 cm)
Slot for
wood strip
5/16”
nut driver
wood strip
1
2
1(413/1
.6 6
cm ”
)
5/16”
nut driver
2
GREEN
BLACK
WHITE
BLACK
WHITE
Connect black to black, white to white, and the
green/bare wire under the green screw.
NOTE: Housing wiring must be properly installed for
wiring to be correct when wiring unit.
Replace electrical box cover. Make connection to
breaker box.
10
11
Measure down 1-13/16 (4.6 cm) from desired height of
hood and secure 1-1/2” x 3/4” wood strip (provided
locally) to wall using screws provided.
Use additional mounting screws to secure hood to
wood strip.
3
1
5/16”
nut driver
5/16”
nut driver
2
3
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
Assemble brackets to baffles and insert charcoal filters.
13
12
CAUTION: If not using a duct cover, using screws
provided, make sure top mounting screws are secured
into soffit or cabinet framing use additional mounting
screws, if necessary.
5
4
1
1
CAUTION: Secure vent hood to wall using screws
provided. Use additional mounting screws and wall
anchors, if necessary.
1
1
1
2
3
3
3
2
3
2
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
Slide spacer front over front lip. Push spacer rear up,
then slide back over rear lip.
32
2
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
33
Duct Cover Option (VWH 18”H. Wall Hoods)
2
1
Measure distance from ceiling to canopy.
Duct Cover Option
2
1
(VCWH Chimney Wall Hoods)
2
Measure distance from ceiling to canopy.
Slide the duct cover in place and fasten from inside
canopy using the sheet metal screws provided.
Tape to avoid scratching.
3
4
To install ventillation kit
refer to ventillation kit
installation instructions.
Place duct cover top inside duct cover base and lower until
desired height is found. Mark height. Use the retaining
nuts and bolts to fasten in place and remove tape.
34
Slide the duct cover in place and fasten from inside
canopy using the sheet metal screws provided.
35
Installation (VCIH Island Hoods)
2
1
Check framing where cutout will be.
NOTE: 200 lb. limit.
Cut appropriate size hole in ceiling. Either 7” or 10”
depending on your specific unit and ventillator kit.
A1
Mounting options:
Installation (VCIH Island Hoods)
4
3
5/16”
nut
driver
Run duct work down to bottom edge of duct
cover/soffit and secure in place. Make sure the duct
does not stick down past the cover.
Attach canopy to duct cover/soffit. Seal top of hood to
duct with aluminum tape.
6
5
1
Using duct cover with ceiling mounting
bracket. (Option A - VCIH only)
1
Using threaded rod for additional support.
(Option B)
Attaching hood directly to soffit or
duct cover.
(Skip to step 3)
1
3
3
2
Attach duct cover to optional ceiling mounting bracket.
A2
2
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
B1
5/16”
nut
driver
To install ventillation kit
refer to ventillation kit
installation instructions.
Additional support option. Drill holes in all four corners
for threaded rod and run rods from hood to ceiling.
Attach duct cover to ceiling. The ceiling bracket can be
hidden by using a locally supplied trim.
36
37
Service & Registration
If service is required, call your dealer or authorized service agency.
The name of the authorized service agency can be obtained from the dealer or distributor in
your area.
Have the following information readily available.
• Model number
• Serial number
• Date purchased
• Name of dealer from whom purchased
Clearly describe the problem that you are having. If you are unable to obtain the name of an
authorized service agency, or if you continue to have service problems, contact Viking Range,
LLC at1-888-(845-4641), online at vikingrange.com or write to:
VIKING RANGE, LLC
PREFERRED SERVICE
111 Front Street
Greenwood, Mississippi 38930 USA
Record the information indicated below. You will need it if service is ever required. The model
and serial number for your hood is located behind the baffle filter on the left side panel in the lower
right corner.
Model no. _____________________ Serial no. ________________________
Date of purchase _______________ Date installed ___________________
Dealer’s name __________________________________________________
Address ________________________________________________________
_______________________________________________________________
If service requires installation of parts, use only authorized parts to ensure protection under the
warranty.
THIS MANUAL SHOULD REMAIN WITH THE HOOD FOR FUTURE REFERENCE.