D3-330 & D3-340 DL305 PLC CPUs Technical Specs

D3-330 & D3-340 DL305 PLC CPUs Technical Specs
Prices as of April 27, 2016. Check Web site for most current prices.
D3-330 and D3-340 Key Features
D3-330
D3-340
$459.00
$631.00
DL330
The diagram to the right shows the
various hardware features found on the
D3-330 and D3-340 CPUs.
RUN
CPU is in RUN mode
CPU is in Program mode
BATT
ON OFF
Memory backup voltage low
Memory backup voltage good
CPU
ON OFF
CPU failure
CPU is good
PWR
(Power)
ON
OFF
CPU power good
CPU power failure
Port1
RX/TX
(D3-340)
RED
Flashing red indicates the CPU port is
receiving data
Flashing green indicates the CPU port
is sending data
Port2
RX/TX
(D3-340
GREEN
RED
Green
R UN
P WR
R UN
P ORT1
TX/R X
BATT
P ORT2
TX/R X
CP U
Peripheral port
(HP, DCU,
UVPROM writer)
D3-CPU-UV $148.00 Optional
UVPROM memory. Four chips per pack.
(Only one chip is required for the CPU.)
A D3-PWU Prom Writer Unit is required
for programming.
D3-340-EE $171.00
Do-More H2
PLC
Do-More T1H
PLC
US E R
DirectLOGIC
PLCs Overview
RS232C
Communication Ports
-DirectSOFT
-DirectNET
-Operator interfaces
P OWER
DirectLOGIC
DL05/06
DirectLOGIC
DL105
PRG
R S 232C
DirectLOGIC
DL205
P IN
Number S ignal
R XD
1
2
TXD
3
RTS
4
GND
D3-340 RS232C Communication Port Specs
CTS
RTS
TXD
R XD
DirectLOGIC
DL305
Protocol
DirectNET
Connector
Network address
RJ11(handset connector)
01 to 90
DirectLOGIC
DL405
Baud rate
38400, 19200, 9600, 4800, 2400, 1200, 600, 300
Parity-
None or odd
Productivity
Controller
Overview
Transfer mode
HEX/ASCII
Half-duplex
Asynchronous
Data bits
Start bits
Stop bits
8
1
1
Turn around delay
0 to 1980 in 20ms intervals (preset with R777)
Hardware switches
Below is a side view of a D3-340 CPU
that shows several types of hardware
switches.
The D3-330 has a 2-position dipswitch
for selecting retentive memory and
jumpers for selecting UVPROM and RAM
options.
Productivity
3000
Universal
Field I/O
The D3-340 has a jumper switch for
selecting UVPROM, EEPROM and RAM
options, two rotary switches to select
network addresses and an eight-position dipswitch for selecting baud rates
(300 to 38.4K baud), communication
mode (slave, master, Modbus RTU) and
memory options.
Optional EEPROM memory for the
D3-340 only. Four chips per pack. (Only
one chip is required for the CPU.) No
additional programming device is necessary.
D3-D4-BAT
Do-More
PLCs Overview
F IXE D
Network address
mode switch
GND
The DL305 CPUs come with on-board
RAM and a battery. If you need additional program security, you may want
to choose the EEPROM or UVPROM
memory.
CLICK PLC
DL340
BATT
CP U
Flashing red indicates the CPU port is
receiving data
Flashing green indicates the CPU port
is sending data
EEPROM and UVPROM
chips
Control Systems
Overview
LED
indicators
CPU Status Indicators
ON
OFF
Company
Information
Software
C-More
HMI
C-More Micro
HMI
ViewMarq
Industrial
Marquees
Other HMI
Communications
Appendix
Book 1
Address range
SW4
$54.00
SW3
Spare battery (lithium 3.0V). Also used
for D4-430 and D4-440 CPUs.
R AM/UVP R OM
Most significant
digit for address
Ports
Least significant
digit for address
Battery
Book 1 (14.3)
www.automationdirect.com/dl305
DL305 PLCs
eD3-11
Terms and
Conditions
Prices as of April 27, 2016. Check Web site for most current prices.
CPU Specifications
Company
Information
Control Systems
Overview
DL305 CPU Specifications
System Capacity
D3-330
D3-340
D3-350
Total memory (K words)
Ladder memory (K words)
User data memory
CMOS RAM
UVPROM
EEPROM
Total I/O points using:
Local I/O
Local and Expansion I/O
Remote I/O1
I/O point density
Slots per base (CPU requires 1 slot)
3.91
3.7
116 bytes
Yes
Opt.
No
3.98
3.7
172 bytes
Yes
Opt.
Opt.
14.8
7.6
7.1K words
No
No
Flash
128
176
N/A
8/16
5/8/10
136
184
N/A
8/16
5/8/10
144
368
512
8/16
5/8/10
6.6µs
15ms
.87µs
4-5ms
.61µs
5-6ms
CLICK PLC
Do-More
PLCs Overview
Do-More H2
PLC
Do-More T1H
PLC
DirectLOGIC
PLCs Overview
DirectLOGIC
DL05/06
Performance
Contact execution (boolean)
Typical scan (1K boolean)2
DirectLOGIC
DL105
DirectLOGIC
DL205
Programming & Diagnostics
RLL ladder style
RLLPLUS (stage)
RunTime Editing
Supports Overrides
Variable/fixed scan
Handheld programmer port
Built-in RS232C ports
Real-time clock/calendar
Instructions
Control relays(CR)
Shift register bits
Stages (RLLPLUS only)
Timers/counters
Immediate I/O
Subroutines
For/Next Loops
Timed interrupt
Integer math
Floating point math
PID
Drum sequence
Bit of word
ASCII print
Data registers
Internal diagnostics
Password security
Battery backup
Yes
No
No
No
variable
Yes
No3
No
61
140
128
N/A
64
No
No
No
No
Yes
No
No
No
No
No
128
Yes
Yes
Yes
Yes
No
No
No
variable
Yes
2
No
63
196
128
N/A
64
No
No
No
No
Yes
No
No
No
No
No
192
Yes
Yes
Yes
Yes
Yes
Yes
Yes
either
Yes
2
Yes
129
1024
use CRs
1024
256/128
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
7168
Yes
Multi-level
Yes
No
No
w/DCU
No
No
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
N/A
Yes
112
28
Yes
Yes
128
32
Yes
Yes
368
48
No
DirectLOGIC
DL305
DirectLOGIC
DL405
Productivity
Controller
Overview
Productivity
3000
Universal
Field I/O
Software
C-More
HMI
C-More Micro
HMI
ViewMarq
Industrial
Marquees
Other HMI
Communications
Built-in ports3
DirectNET master
DirectNET slave
MODBUS RTU master
MODBUS RTU slave
Data communications unit
Communications
Appendix
Book 1
Terms and
Conditions
Specialty modules
Thermocouple
Analog Input (#channels max.)
Analog output (#channels max.)
High-speed counter (10KHz)
1. T he D3-350 bottom port supports DL205 remote I/O.
2. 1 K program includes contacts, coils, and scan
overhead. If you compare to other products,
make sure to include their scan overhead.
3. T he D3-330 requires a Data Communications Unit
(DCU) for programming with DirectSOFT software.
Book 1 (14.3)
www.automationdirect.com/dl305
DL305 PLCs
eD3-7
Prices as of April 27, 2016. Check Web site for most current prices.
Communications
Determine your
communications
requirements
The choice of CPU can have a big impact
on your communications capabilities in
the DL305 family. If you are considering
doing any communications, you should
use the D3-340 or the D3-350 CPUs.
You can communicate with the D3-330
CPU, but you have to add a DL305
Data Communications Unit to connect
any device other than a handheld
programmer. The Data Communications
Unit has only one port.
D3-340 RS232C Communication Port
Specifications
Protocol
DirectNET
Connector
Network address
RJ11(handset connector)
01 to 90
Baud rate
38400, 19200, 9600, 4800,
2400, 1200, 600, 300
Parity-
None or odd
Transfer mode
HEX/ASCII
Half-duplex
Asynchronous
Data bits
Start bits
Stop bits
8
1
1
Turn around delay
0 to 1980 in 20ms intervals
(preset with R777)
CPU with built-in
communication ports
Connect to either
port RS232C
Company
Information
Control Systems
Overview
Standard
communications
DL305 as a
network master
The D3-340 and D3-350 CPUs offer two
built-in RS232C communication ports.
Operator interfaces and DirectSOFT
can be connected to either port. On the
D3-340 CPU, the handheld programmer
is attached directly or with a cable to
the parallel port adjacent to the two
serial communication ports. On the
D3-350 CPU, the handheld programmer
is attached to Port 1. The handheld
programmer can be operated simultaneously with the communication
ports. The D3-340 baud rate and
network addresses are set by hardware
dipswitches and rotary switches for Port 1.
Port 2 uses internal registers that can be
changed with a handheld programmer
or DirectSOFT. Port 1 on the D3-350 is
fixed. Port 2 can be configured using the
handheld programmer or DirectSOFT.
The bottom built-in communication
port of the D3-340 and D3-350 CPUs
can serve as a Network Master for
DirectNET. Up to 90 slave stations can be
addressed. The D3-350 can also serve
as a MODBUS RTU Master; up to 247
slave stations can be addressed. DL405,
DL305 and DL205 controllers can be
used as slave stations. (Please note there
are certain restrictions pertaining to valid
DL205 and DL405 memory types that the
D3-340 master can read and write.)
DL305 as a slave
on a network
Both ports on the D3-340 and the
D3-350 CPUs can serve as slave ports
for DirectNET. The bottom ports offer
additional flexibility in that they can serve
as a slave on a Modbus RTU network.
The D3-350 even supports RS422, so no
RS232-to-RS422 converter is needed. No
programming is required in these CPUs
for them to act as slave ports.
CLICK PLC
Custom drivers
The DL305 product family supports the
DirectNET protocol. However, in some
applications you may have a need to
connect to a device that does not support
this protocol. If so, the ASCII/BASIC
modules also allow you to write your own
custom communication drivers (in BASIC)
to connect to special devices. These highspeed modules offer communication rates
up to 115.2K baud on RS232C, RS422,
and RS485. With 128K of memory, there
is ample program or data storage space.
(These modules are not supported by the
D3-350.)
Do-More
PLCs Overview
Do-More H2
PLC
Do-More T1H
PLC
DirectLOGIC
PLCs Overview
DirectLOGIC
DL05/06
DirectLOGIC
DL105
DirectLOGIC
DL205
DirectLOGIC
DL305
DirectLOGIC
DL405
Productivity
Controller
Overview
Productivity
3000
Universal
Field I/O
Software
C-More
HMI
C-More Micro
HMI
ViewMarq
Industrial
Marquees
Other HMI
Handheld programmer
Communications
Appendix
Book 1
Terms and
Conditions
DL205/305/405 slaves
Network Addresses
Port
Protocol
Range
1
Slave
1-90
Slave
1-90
Master
0
MODBUS/RTU
1-247
2
FA-UNICON
FA-ISOCON
FA-UNICON
D2-240
D3-340
D4-430/440/450
Book 1 (14.3)
www.automationdirect.com/dl305
DL305 PLCs
eD3-13