Prices as of April 27, 2016. Check Web site for most current prices. D3-330 and D3-340 Key Features D3-330 D3-340 $459.00 $631.00 DL330 The diagram to the right shows the various hardware features found on the D3-330 and D3-340 CPUs. RUN CPU is in RUN mode CPU is in Program mode BATT ON OFF Memory backup voltage low Memory backup voltage good CPU ON OFF CPU failure CPU is good PWR (Power) ON OFF CPU power good CPU power failure Port1 RX/TX (D3-340) RED Flashing red indicates the CPU port is receiving data Flashing green indicates the CPU port is sending data Port2 RX/TX (D3-340 GREEN RED Green R UN P WR R UN P ORT1 TX/R X BATT P ORT2 TX/R X CP U Peripheral port (HP, DCU, UVPROM writer) D3-CPU-UV $148.00 Optional UVPROM memory. Four chips per pack. (Only one chip is required for the CPU.) A D3-PWU Prom Writer Unit is required for programming. D3-340-EE $171.00 Do-More H2 PLC Do-More T1H PLC US E R DirectLOGIC PLCs Overview RS232C Communication Ports -DirectSOFT -DirectNET -Operator interfaces P OWER DirectLOGIC DL05/06 DirectLOGIC DL105 PRG R S 232C DirectLOGIC DL205 P IN Number S ignal R XD 1 2 TXD 3 RTS 4 GND D3-340 RS232C Communication Port Specs CTS RTS TXD R XD DirectLOGIC DL305 Protocol DirectNET Connector Network address RJ11(handset connector) 01 to 90 DirectLOGIC DL405 Baud rate 38400, 19200, 9600, 4800, 2400, 1200, 600, 300 Parity- None or odd Productivity Controller Overview Transfer mode HEX/ASCII Half-duplex Asynchronous Data bits Start bits Stop bits 8 1 1 Turn around delay 0 to 1980 in 20ms intervals (preset with R777) Hardware switches Below is a side view of a D3-340 CPU that shows several types of hardware switches. The D3-330 has a 2-position dipswitch for selecting retentive memory and jumpers for selecting UVPROM and RAM options. Productivity 3000 Universal Field I/O The D3-340 has a jumper switch for selecting UVPROM, EEPROM and RAM options, two rotary switches to select network addresses and an eight-position dipswitch for selecting baud rates (300 to 38.4K baud), communication mode (slave, master, Modbus RTU) and memory options. Optional EEPROM memory for the D3-340 only. Four chips per pack. (Only one chip is required for the CPU.) No additional programming device is necessary. D3-D4-BAT Do-More PLCs Overview F IXE D Network address mode switch GND The DL305 CPUs come with on-board RAM and a battery. If you need additional program security, you may want to choose the EEPROM or UVPROM memory. CLICK PLC DL340 BATT CP U Flashing red indicates the CPU port is receiving data Flashing green indicates the CPU port is sending data EEPROM and UVPROM chips Control Systems Overview LED indicators CPU Status Indicators ON OFF Company Information Software C-More HMI C-More Micro HMI ViewMarq Industrial Marquees Other HMI Communications Appendix Book 1 Address range SW4 $54.00 SW3 Spare battery (lithium 3.0V). Also used for D4-430 and D4-440 CPUs. R AM/UVP R OM Most significant digit for address Ports Least significant digit for address Battery Book 1 (14.3) www.automationdirect.com/dl305 DL305 PLCs eD3-11 Terms and Conditions Prices as of April 27, 2016. Check Web site for most current prices. CPU Specifications Company Information Control Systems Overview DL305 CPU Specifications System Capacity D3-330 D3-340 D3-350 Total memory (K words) Ladder memory (K words) User data memory CMOS RAM UVPROM EEPROM Total I/O points using: Local I/O Local and Expansion I/O Remote I/O1 I/O point density Slots per base (CPU requires 1 slot) 3.91 3.7 116 bytes Yes Opt. No 3.98 3.7 172 bytes Yes Opt. Opt. 14.8 7.6 7.1K words No No Flash 128 176 N/A 8/16 5/8/10 136 184 N/A 8/16 5/8/10 144 368 512 8/16 5/8/10 6.6µs 15ms .87µs 4-5ms .61µs 5-6ms CLICK PLC Do-More PLCs Overview Do-More H2 PLC Do-More T1H PLC DirectLOGIC PLCs Overview DirectLOGIC DL05/06 Performance Contact execution (boolean) Typical scan (1K boolean)2 DirectLOGIC DL105 DirectLOGIC DL205 Programming & Diagnostics RLL ladder style RLLPLUS (stage) RunTime Editing Supports Overrides Variable/fixed scan Handheld programmer port Built-in RS232C ports Real-time clock/calendar Instructions Control relays(CR) Shift register bits Stages (RLLPLUS only) Timers/counters Immediate I/O Subroutines For/Next Loops Timed interrupt Integer math Floating point math PID Drum sequence Bit of word ASCII print Data registers Internal diagnostics Password security Battery backup Yes No No No variable Yes No3 No 61 140 128 N/A 64 No No No No Yes No No No No No 128 Yes Yes Yes Yes No No No variable Yes 2 No 63 196 128 N/A 64 No No No No Yes No No No No No 192 Yes Yes Yes Yes Yes Yes Yes either Yes 2 Yes 129 1024 use CRs 1024 256/128 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 7168 Yes Multi-level Yes No No w/DCU No No Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes Yes N/A Yes 112 28 Yes Yes 128 32 Yes Yes 368 48 No DirectLOGIC DL305 DirectLOGIC DL405 Productivity Controller Overview Productivity 3000 Universal Field I/O Software C-More HMI C-More Micro HMI ViewMarq Industrial Marquees Other HMI Communications Built-in ports3 DirectNET master DirectNET slave MODBUS RTU master MODBUS RTU slave Data communications unit Communications Appendix Book 1 Terms and Conditions Specialty modules Thermocouple Analog Input (#channels max.) Analog output (#channels max.) High-speed counter (10KHz) 1. T he D3-350 bottom port supports DL205 remote I/O. 2. 1 K program includes contacts, coils, and scan overhead. If you compare to other products, make sure to include their scan overhead. 3. T he D3-330 requires a Data Communications Unit (DCU) for programming with DirectSOFT software. Book 1 (14.3) www.automationdirect.com/dl305 DL305 PLCs eD3-7 Prices as of April 27, 2016. Check Web site for most current prices. Communications Determine your communications requirements The choice of CPU can have a big impact on your communications capabilities in the DL305 family. If you are considering doing any communications, you should use the D3-340 or the D3-350 CPUs. You can communicate with the D3-330 CPU, but you have to add a DL305 Data Communications Unit to connect any device other than a handheld programmer. The Data Communications Unit has only one port. D3-340 RS232C Communication Port Specifications Protocol DirectNET Connector Network address RJ11(handset connector) 01 to 90 Baud rate 38400, 19200, 9600, 4800, 2400, 1200, 600, 300 Parity- None or odd Transfer mode HEX/ASCII Half-duplex Asynchronous Data bits Start bits Stop bits 8 1 1 Turn around delay 0 to 1980 in 20ms intervals (preset with R777) CPU with built-in communication ports Connect to either port RS232C Company Information Control Systems Overview Standard communications DL305 as a network master The D3-340 and D3-350 CPUs offer two built-in RS232C communication ports. Operator interfaces and DirectSOFT can be connected to either port. On the D3-340 CPU, the handheld programmer is attached directly or with a cable to the parallel port adjacent to the two serial communication ports. On the D3-350 CPU, the handheld programmer is attached to Port 1. The handheld programmer can be operated simultaneously with the communication ports. The D3-340 baud rate and network addresses are set by hardware dipswitches and rotary switches for Port 1. Port 2 uses internal registers that can be changed with a handheld programmer or DirectSOFT. Port 1 on the D3-350 is fixed. Port 2 can be configured using the handheld programmer or DirectSOFT. The bottom built-in communication port of the D3-340 and D3-350 CPUs can serve as a Network Master for DirectNET. Up to 90 slave stations can be addressed. The D3-350 can also serve as a MODBUS RTU Master; up to 247 slave stations can be addressed. DL405, DL305 and DL205 controllers can be used as slave stations. (Please note there are certain restrictions pertaining to valid DL205 and DL405 memory types that the D3-340 master can read and write.) DL305 as a slave on a network Both ports on the D3-340 and the D3-350 CPUs can serve as slave ports for DirectNET. The bottom ports offer additional flexibility in that they can serve as a slave on a Modbus RTU network. The D3-350 even supports RS422, so no RS232-to-RS422 converter is needed. No programming is required in these CPUs for them to act as slave ports. CLICK PLC Custom drivers The DL305 product family supports the DirectNET protocol. However, in some applications you may have a need to connect to a device that does not support this protocol. If so, the ASCII/BASIC modules also allow you to write your own custom communication drivers (in BASIC) to connect to special devices. These highspeed modules offer communication rates up to 115.2K baud on RS232C, RS422, and RS485. With 128K of memory, there is ample program or data storage space. (These modules are not supported by the D3-350.) Do-More PLCs Overview Do-More H2 PLC Do-More T1H PLC DirectLOGIC PLCs Overview DirectLOGIC DL05/06 DirectLOGIC DL105 DirectLOGIC DL205 DirectLOGIC DL305 DirectLOGIC DL405 Productivity Controller Overview Productivity 3000 Universal Field I/O Software C-More HMI C-More Micro HMI ViewMarq Industrial Marquees Other HMI Handheld programmer Communications Appendix Book 1 Terms and Conditions DL205/305/405 slaves Network Addresses Port Protocol Range 1 Slave 1-90 Slave 1-90 Master 0 MODBUS/RTU 1-247 2 FA-UNICON FA-ISOCON FA-UNICON D2-240 D3-340 D4-430/440/450 Book 1 (14.3) www.automationdirect.com/dl305 DL305 PLCs eD3-13
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement