OmniStar ® GX2
Headend Optics Platform
GX2‐RX1000B
Forward Path Receiver
FEATURES
• Integrated low‐noise preamp and high‐performance post amplifier allows a high RF output level and exceptional distortion performance
• Up to 16 receiver modules in a four rack‐unit housing provide high module density
• Quick‐Swap Capability allows for replacement modules to be recognized and updated with previously stored settings
• Wide input range from –9 to +3 dBm with variable gain and slope controls to accommodate various system architectures
PRODUCT OVERVIEW
The Omnistar® GX2 forward path receiver is designed for headend and hub applications using standard Hybrid Fiber Coax Cable
Television wavelengths. The receiver features gain and slope controls to easily accommodate varying link budgets and support headend splitting and cabling requirements. The hot‐swappable modules, which feature unique embedded features like Quick‐Swap
Module Configuration, maximize in‐service time by eliminating the need for manual configuration. The adjustable features and high
RF gain of these receivers, coupled with the full complement of other OmniStar GX2 application modules, provide extreme flexibility for network design and fiber link optimization.
Fiber‐Deep
Ask us about the complete Access Technologies Solutions portfolio:
DOCSIS ® 3.1
Node Segmentation HPON ™ /RFoG
Headend Optics‐GX2
FTTx
OmniStar® GX2‐RX1000B
The GX2‐RX1000B occupies one slot in the GX2‐HSG universal shelf. The standard SC/APC optical input connector is located on the front of the module for easy cleaning and installation. The dual fans on each module are field‐replaceable, and the fan current is monitored to provide operational status.
Operators can manually adjust the receiver’s RF gain and slope. Gain control allows operators to adjust the RF output level for customized C/N and distortion performance based on channel loading and system requirements. The slope control is designed to compensate for the forward link slope and cable length that might follow the GX2‐RX1000B within the headend or hub area. The
0 to +3 dB slope control range can compensate for up to approximately 50 feet of RG59 headend coaxial cable.
Module Features
The receiver’s front panel RF test point directly monitors the RF output and allows operators to conveniently setup and maintain the receiver. A blind mate RF output connector on the rear of the module allows operators to hot‐swap modules without disconnecting cables from the back panel of the housing. To provide path and equipment redundancy, the GX2‐RX1000B is designed to interface with both the OmniStar® GX2 RF Switch and the Optical Switch. Firmware is downloadable, and operators can upgrade firmware while the module remains in operation. No hardware changes are needed.
Communications
The GX2‐RX1000B supports several communication methods for real‐time system monitoring and control. A tri‐colored LED on each module indicates general operating status. The optional shelf door unit with display provides monitoring and control with an alphanumeric display and simple push button navigation. Finally, a PC interface is available through an Ethernet port on the front of the control module. Using a standard Web browser, the graphical user interface provides a point‐and‐click method of monitoring and controlling the shelf. For higher‐level management, the OmniStar GX2 can be easily connected to a remote network management system using the standard Ethernet SNMP interface.
Estimated Receiver Output Levels
Received Optical Input Level Range @ 1310 nm (dBm)
–4
–3
–2
–1
0
–9
–8
–7
–6
–5
+1
+2
+3
STO
SSO
RF Output Level @ 870 MHz (dBmV)
–1.8 to 8.2
0.2 to 10.2
2.2 to 12.2
4.2 to 14.2
6.2 to 16.2
8.2 to 18.2
10.2 to 20.2
12.2 to 22.2
14.2 to 24.2
16.2 to 26.2
18.2 to 28.2
20.2 to 30.2
22.2 to 32.2
–85 dBc Max. (47 – 1000 MHz @ 0 dBm Optical Input Level 2 signals @ 20% OMI ea)
–75 dBc Max. (47 – 870 MHz @ 0 dBm Optical Input Level, 2 signals @ 20% OMI ea)
Fiber‐Deep
Ask us about the complete Access Technologies Solutions portfolio:
DOCSIS ® 3.1
Node Segmentation HPON ™ /RFoG
Headend Optics‐GX2
FTTx
OmniStar® GX2‐RX1000B
SPECIFICATIONS
Optical
Optical Wavelength
Optical Input Power
Equivalent Input Noise Current
Optical Return Loss
Optical Connector Types
RF
Operational Bandwidth
Gain
Gain Control Range
Slope Control Range
RF Output Level
RF Flatness
RF Output Test Point
RF Output Impedance
RF Output Return Loss
RF Connector Types
Input
Test Points
General
Dimensions
Weight
Mounting
Operating Temperature Range
Storage Temperature Range
Power Consumption
Visual Interface
Data/Control Interface
1290 nm – 1600 nm
–9 to +3 dBm
9 pA/ Hz
0.5
Max. @ Min. atten. 0 dBm input
40 dB Min.
SC/APC
47 – 1000 MHz
21 dB Min. (47 – 870 MHz); 20 dB Min. (870 – 1000 MHz) (set for response, referred to standard receiver calibration)
10 dB
0 to +3 dB
+26 dBmV per channel, 79 analog channels @ 0 dBm optical input level @ 4% OMI per channel, at full gain
2.0 dB p‐P Max. (47 – 750 MHz); 2.2 dB p‐v Max. (47 – 870 MHz);
2.5 dB p‐P Max. (47 – 1000 MHz); at 0 dB slope over gain range
–20 +/‐0.5 dB Relative to RF Output Port
75 Ohms
13 dB Min. (47 – 1000 MHz) over gain and slope range
F‐type (using G‐to‐F adaptor on chassis)
F‐type
1 in W x 5.9 in H x 15 in D (2.5 cm x 15 cm x 38 cm)
2.0 lbs. (1 kgs)
GX2‐HSG* Equipment Shelf
–20°C to 65°C (–4°F to 149°F)
–40°C to 80°C (–40° F to 176°F)
15 Watts Max.
Tri‐Colored Module Status LED
Serial Peripheral Interface (SPI) to control module ±0.5 dB
Fiber‐Deep
Ask us about the complete Access Technologies Solutions portfolio:
DOCSIS ® 3.1
Node Segmentation HPON ™ /RFoG
Headend Optics‐GX2
FTTx
OmniStar® GX2‐RX1000B
Ordering Guide
Model Name
GX2‐RX1000B
Description
Forward Path Receiver Module, SC/APC optical connector
RELATED PRODUCTS
GX2 Chassis
Power Supplies
Management Module
Optical Patch Cords
Optical Passives
Installation Services
Customer Care
Note: Specifications are subject to change without notice.
Contact Customer Care for product information and sales:
• United States: 866‐36‐ARRIS
• International: +1‐678‐473‐5656
Copyright Statement: ©ARRIS Enterprises, Inc. 2015 All rights reserved. No part of this publication may be reproduced in any form or by any means or used to make any derivative work (such as translation, transformation, or adaptation) without written permission from ARRIS Enterprises, Inc. (“ARRIS”). ARRIS reserves the right to revise this publication and to make changes in content from time to time without obligation on the part of ARRIS to provide notification of such revision or change. ARRIS and the ARRIS logo are all registered trademarks of ARRIS Enterprises, Inc. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and the names of their products. ARRIS disclaims proprietary interest in the marks and names of others. The capabilities, system requirements and/or compatibility with third‐party products described herein are subject to change without notice.
GX2‐RX1000B_DS_01DEC14
(rev 12-2014)
Ask us about the complete Access Technologies Solutions portfolio: Headend Optics‐GX2
Fiber‐Deep DOCSIS ® 3.1
Node Segmentation HPON ™ /RFoG FTTx