GaAs 5RU SSPA Chassis
Indoor Rack Mount
GaAs Solid State Power Amplifiers
5RU Rack Height
650W X-Band 5RU SSPA Chassis
Teledyne Paradise Datacom’s Indoor, Rack Mount (R) series
SSPAs represent the latest in High Power Microwave Amplifier
Technology. The 5RU SSPA chassis achieves the highest power density in the industry along with enhanced maintainability.
Local control is available with a user-friendly front panel interface. Five fault condition LEDs reflect some of the SSPA major
faults states, plus a summary fault indicator. The SSPA online
LED turns green when the amplifier is in Online mode (1:1
Mode) or serves as an AC power indicator in standalone mode.
Local/Remote and Mute/Unmute LEDs show the current control
mode and mute state of the amplifier.
Serial and parallel (contact closure) control is also available
from the rear panel. Our free Universal M&C software allows
monitor and control of the SSPA from a remote computer.
A state of the art thermal platform provides efficient cooling for
the amplifier module and power supplies. This ensures the
highest possible MTBFs for microwave power amplifiers.
Prime power to the amplifier is provided by a separate, external
power supply in an N+1 redundant configuration. A failure of
one power supply module will not take the amplifier off the air.
Teledyne Paradise Datacom LLC
328 Innovation Blvd., Suite 100
State College, PA 16803 USA
Tel: (814) 238-3450
Fax: (814) 238-3829
PAGE 1 OF 7
www.paradisedata.com
FEATURES
• Extremely High Power
Density:
to 1.6 kW X-Band
to 1.6 kW C-Band
to 1.0 kW Ku-Band
• Removable Fan Tray and
Monitor & Control Card
Assembly
• Remote Communication
via RS232/485 or Ethernet
• RF Output Sample Port
• 20 dB Gain Adjustment
• 1RU N+1 Power Supply
• True RF Output Power
Measurement
• Built-in Maintenance
Switch Controller
OPTIONS
• Remote Control Panel
• L-Band Input operation
• Reflected Power Monitor
• Input Sample Port
• Exhaust Duct Adapters
• Redundant Systems
• Phase Combined Systems
Teledyne Paradise Datacom Ltd.
2&3 The Matchyns, London Road, Rivenhall End
Witham, Essex CM8 3HA United Kingdom
Tel: +44(0) 1376 515636
Fax: +44(0) 1376 533764
214165 REV B ECO 18095
Indoor Rack Mount
GaAs Solid State Power Amplifiers
5RU Rack Height
Specifications, C-Band SSPAs
PARAMETER
Frequency Range
Output Power
Typical, Psat
Guaranteed minimum, P1dB
Power Requirements
Line Frequency
Line Power (Voltage)
(typical @ 220 VAC)
NOTES
LIMITS
UNITS
Frequency selection “G”
Frequency selection “A”
Frequency selection “B” 1
Frequency selection “D”
5.750 to 6.475
5.850 to 6.425
5.850 to 6.725
6.425 to 7.025
GHz
GHz
GHz
GHz
HPAC5400ARXXXXP
HPAC5500ARXXXXP
HPAC5600ARXXXXP
HPAC5800ARXXXXP
HPAC510KARXXXXP
HPAC513KARXXXXP
Psat / P1dB
56.0 (400) / 55.0 (316)
57.0 (500) / 56.0 (400)
57.8 (600) / 57.0 (500)
59.0 (800) / 57.7 (590)
60.0 (1000) / 58.7 (750)
61.0 (1250) / 59.7 (933)
dBm (W)
dBm (W)
dBm (W)
dBm (W)
dBm (W)
dBm (W)
.98
47 to 63
2400 (180 to 265)
2800 (180 to 265)
3700 (180 to 265)
4600 (180 to 265)
5500 (180 to 265)
7000 (180 to 265)
Hz
W (VAC)
W (VAC)
W (VAC)
W (VAC)
W (VAC)
W (VAC)
power factor
HPAC5400ARXXXXP
HPAC5500ARXXXXP
HPAC5600ARXXXXP
HPAC5800ARXXXXP
HPAC510KARXXXXP
HPAC513KARXXXXP
Note 1: De-rate output power by 1 dB linearly from 6.425 to 6.725 GHz.
Specifications, X-Band SSPAs
PARAMETER
Frequency Range
Output Power
Typical, Psat
Guaranteed minimum, P1dB
Power Requirements
Line Frequency
Line Power (Voltage)
(typical @ 220 VAC)
NOTES
LIMITS
UNITS
Frequency selection “D” 1
Frequency selection “A”
7.70 to 8.40
7.90 to 8.40
GHz
GHz
HPAX5250ARXXXXP
HPAX5350ARXXXXP
HPAX5500ARXXXXP
HPAX5700ARXXXXP
HPAX510KARXXXXP
Psat / P1dB
54.0 (250) / 53.3 (214)
55.5 (354) / 54.5 (282)
57.0 (500) / 56.0 (400)
58.5 (700) / 57.2 (525)
60.0 (1000) / 58.7 (740)
dBm (W)
dBm (W)
dBm (W)
dBm (W)
dBm (W)
.98
47 to 63
2450 (180 to 265)
3000 (180 to 265)
3500 (180 to 265)
6000 (180 to 265)
7000 (180 to 265)
Hz
W (VAC)
W (VAC)
W (VAC)
W (VAC)
W (VAC)
power factor
HPAX5250ARXXXXP
HPAX5350ARXXXXP
HPAX5500ARXXXXP
HPAX5700ARXXXXP
HPAX510KARXXXXP
Note 1: De-rate output power by 1 dB linearly from 7.90 to 7.70 GHz.
Specifications, Ku-Band SSPAs
PARAMETER
NOTES
LIMITS
UNITS
Frequency Range
Frequency selection “F”
Frequency selection “B” 1
Frequency selection “A”
12.75 to 13.25
13.75 to 14.50
14.00 to 14.50
GHz
GHz
GHz
HPAK5200ARXXXXP
HPAK5250ARXXXXP
HPAK5400ARXXXXP
HPAK5500ARXXXXP
Psat / P1dB
53.0 (200) / 51.7 (150)
54.0 (250) / 52.7 (190)
56.0 (400) / 54.7 (300)
57.0 (500) / 55.7 (372)
dBm (W)
dBm (W)
dBm (W)
dBm (W)
.98
47 to 63
2200 (180 to 265)
2400 (180 to 265)
5000 (180 to 265)
5600 (180 to 265)
Hz
W (VAC)
W (VAC)
W (VAC)
W (VAC)
Output Power
Typical, Psat
Guaranteed minimum, P1dB
Power Requirements
Line Frequency
Line Power (Voltage)
(typical @ 220 VAC)
power factor
HPAK5200ARXXXXP
HPAK5250ARXXXXP
HPAK5400ARXXXXP
HPAK5500ARXXXXP
Note 1: De-rate output power by 1 dB linearly from 14.00 to 13.75 GHz.
PAGE 2 OF 7
214165 REV B ECO 18095
Indoor Rack Mount
GaAs Solid State Power Amplifiers
5RU Rack Height
Common Electrical Specifications
PARAMETER
NOTES
LIMITS
UNITS
range
full band
full band (Extended C-Band)
per 40 MHz
0 °C to +50 °C
at constant temperature
0.1 dB resolution
55-75
± 1.0
± 1.5
± 0.3
± 1.0
± 0.25
20
dB
dB
dB
dB/40 MHz
dB
dB / 24 hours
dB
At P1dB (Psat - 3 dB)
-25
dBc
AM/PM Conversion
@ rated P1dB
≤ 1.0
Spurious
Harmonics (SSPA only)
@ rated P1dB
@ rated P1dB
-65
-50
Extended C-Band
Output VSWR: Ku-Band with bulkhead filter
1.30:1
1.50:1
1.40:1
Gain
Gain Flatness
Gain Slope
Gain Variation vs. Temperature
Gain Stability
Gain Adjustment
Intermodulation Distortion
(Two-tone, 5 MHz spacing)
Input/Output VSWR
Noise Figure
o
/dB
dBc
dBc
at maximum gain
10
dB
Group Delay
(per 40 MHz segment)
Linear
Parabolic
Ripple
0.01
0.003
1.0
ns/MHz
ns/MHz2
ns p-p
Transmit Band Noise
Output Power Density
TX Band
-75
dBW/4 KHz
Offset frequency from carrier
1 Hz
10 Hz
100 Hz
1 KHz
10 KHz
100 KHz
1 MHz
-110
-120
-130
-135
-140
-140
-140
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
Offset frequency from carrier
10 Hz
100 Hz
1 KHz
10 KHz
100 KHz
1 MHz
-90
-100
-110
-120
-125
-130
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
Range
Accuracy
Psat to (Psat - 20)
± 0.5
dB
dBm
Residual AM Noise, typical
Residual Phase Noise, typical
(SSPA only)
True RF Power Detector
Specifications are subject to change without notice.
1RU N+1 Redundant Power Supply
The combination of a separate, fully redundant power supply is an excellent means of obtaining the ultimate in system reliability. The power supply is an N+1 redundant configuration,
meaning that there is one more power supply module available than required to operate the
SSPA. A failure of one power supply module will not take the amplifier off the air.
PAGE 3 OF 7
214165 REV B ECO 18095
Indoor Rack Mount
GaAs Solid State Power Amplifiers
5RU Rack Height
L-Band Operation
Teledyne Paradise Datacom amplifiers are available with an integrated L-Band Block Up
Converter. L-Band units utilize Teledyne Paradise Datacom’s proprietary zBUC technology.
The addition of a zBUC® converter to the SSPA typically increases the gain by 2-4 dB. The
advantages of zBUC technology include:
• zBUC converter can detect and switch to an extenally supplied reference.
• Optional internal high stability (10MHz) reference.
• zBUC converter can lock to an externally supplied reference of 10 or 50 MHz.
• zBUC converter can accept a wide range of external reference power (-10 to +5 dBm).
Available Frequency Plans
Band
Frequency Band
IF Input
LO Frequency
RF Output
Gain Change
C
Standard C-Band
950 - 1525 MHz
4.900 GHz
5.850 - 6.425 GHz
0-4 dB
C
Extended C-Band
950 - 1825 MHz
4.900 GHz
5.850 - 6.725 GHz
0-4 dB
C
Palapa Band
950 - 1250 MHz
5.475 GHz
6.425 - 6.725 GHz
0-4 dB
C
Insat Band
950 - 1250 MHz
5.775 GHz
6.725 - 7.025 GHz
0-4 dB
C
Extended C-Band 2
950 - 1675 MHz
4.800 GHz
5.750 - 6.475 GHz
0-4 dB
C
Low C-Band
840 - 1000 MHz
4.250 GHz
5.090 - 5.250 GHz
0-4 dB
X
Standard X-Band
950 - 1450 MHz
6.950 GHz
7.900 - 8.400 GHz
0-2 dB
Ku
Standard Ku-Band
950 - 1450 MHz
13.050 GHz
14.00 - 14.50 GHz
0-2 dB
Ku
Extended Ku-Band
950 - 1700 MHz
12.800 GHz
13.75 - 14.50 GHz
0-2 dB
Electrical Specifications for 5RU RM SSPA with ZBUC converter
PARAMETER
Gain
Gain Flatness
Gain Slope
Gain Adjusted Range
Gain Stability
Phase Noise
Spurious
NOTES
LIMITS
UNITS
Nominal setting
full band (C-,X-,Ku-bands)
per 40 MHz (C-,X-,Ku-bands)
75
± 2.0
± 0.5
20
60 - 80
57 - 77
± 1.5
dB
dB
dB/40 MHz
dB
dB
dB
dB
Typical C-Band Adj. Range
Typical Ku-Band Adj. Range
-40 to +60 °C
Offset frequency from carrier
10 Hz
100 Hz
1 KHz
10 KHz
100 KHz
1 MHz
Absolute max.
-30
-60
-70
-80
-90
-90
C-band (typ.)
-60
-80
-80
-85
-120
-125
In-Band Signal Related (C-/Ku-Band)
(Extended C-Band)
Close to Carrier Spurious (≤ 20 MHz)
Local Oscillator
X-band (typ.)
-60
-75
-75
-100
-110
-122
Ku-band (typ.)
-50
-65
-72
-90
-110
-120
-50
-40
-50
-30
dBc
dBc
dBc
dBm
dB
Noise Figure
At 75 dB gain setting
20
Input VSWR
L-Band
1.5 : 1
Reference Accuracy (initial)
Aging per day (after 30 days)
Aging per year (after 30 days)
Reference Stability over Temperature (-40 to +40 °C, ambient)
± 1 • 10-8
± 1 • 10-9
± 6 • 10-8
± 1 • 10-8
Internal Reference Option
PAGE 4 OF 7
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
214165 REV B ECO 18095
Indoor Rack Mount
GaAs Solid State Power Amplifiers
5RU Rack Height
Mechanical Specifications
NOTES
LIMITS
UNITS
Size (SSPA)
PARAMETER
width X height X depth
19.0 x 8.75 x 30.0
483 x 222 x 762
inches
mm
Size (Power Supply)
width X height X depth
19.0 x 1.75 x 15.97
483 x 45 x 406
inches
mm
With integrated zBUC converter
120 (54.5)
+1.7 (+0.8)
lbs. (kg)
lbs. (kg)
with four (4) power supply modules
29 (13.2)
lbs. (kg)
Paint
Gray; powder coat
Type N
WR137 Waveguide
WR112 Waveguide
WR75 Waveguide
Type N
Female
CPR137G Flange (PDR-70)
CPR112G Flange (PDR-84)
Grooved flange (PBR-120)
Female
Weight (SSPA)
Weight (Power Supply)
Finish
Connectors
RF Input
RF Output (C-Band)
RF Output (X-Band)
RF Output (Ku-Band)
RF Output Sample
Environmental Specifications
PARAMETER
Operating Temperature
NOTES
LIMITS
UNITS
Ambient
0 to +50
°C
Non-condensing
95
%
Cooling System
Forced Convection Air Cooling
Front Panel - Intake
Rear Panel - Exhaust
Audible Noise
Measured 1m from unit, at Psat
61
Relative Humidity
Altitude
dBA
No temperature de-rating up to 10,000 ft, (3000 m)
De-rate maximum temperature by 2 °C per 1,000 ft (300 m) beyond 10,000 ft.
Shock
50 g p-p, 11 msec pulses
Vibration
3g rms 30 min. 5-2000 Hz
X-Band Receive Band Filter Option
X-Band GaAs amplifiers may be ordered with an external receive band reject filter. The filter
used for frequency band 7.90 to 8.40 GHZ is model L205250-X6-TX.
PAGE 5 OF 7
214165 REV B ECO 18095
Indoor Rack Mount
GaAs Solid State Power Amplifiers
5RU Rack Height
Redundant and Phase Combined Systems
Teledyne Paradise Datacom’s 5RU Rack Mount SSPAs can be configured in a variety of
redundant and phase combined configurations.
•
•
•
•
•
•
1:1 Redundant System with Internal Redundancy Control
1:1 Redundant System with RCP2-1100 Redundant System Controller
1:1 Fixed Phase Combined System with FPRC-1100 Phase Combined System Controller
1:2 Redundant System with Internal Redundancy Control
1:2 Redundant System with RCP2-1200 Redundant System Controller
1:2 Fixed Phase Combined System with FPRC-1200 Phase Combined System Controller
System Output Power Capacity
Due to residual losses inherent in redundant system configurations (waveguide bends; switch
and coupler losses), reduce the typical output power specification of a single amplifier by
approximately 0.2 dB for 1:1 and by 0.4 dB for 1:2 systems.
In phase combined systems, these same losses result in slightly less than the ideal addition
of 3 dB to the output power of a single HPA unit. For 1:1 phase combined systems, the typical
additive output power is approximately 2.70 dB above the output power of a single HPA. For
1:2 phase combined systems, the typical additive output power is approximately 2.50 dB
above the output power of a single HPA.
Actual system losses will vary based on the system options.
System Controllers
The RCP2/FPRC-1100/1200 system controller provides an extremely user friendly interface
for complete monitor and control of the amplifier system.
RCP2-1100 Redundant System Controller
The front panel mimic display shows the on-line amplifiers and the switch positions. Fault
lights are provided for easy identification of system status. All system monitor and control is
available locally at the front panel LCD display, as well as remotely by the RS232, RS485, or
Ethernet interface ports. Audible alarms and a full compliment of parallel I/O signal are available at the rear panel of the controller.
PAGE 6 OF 7
214165 REV B ECO 18095
Indoor Rack Mount
GaAs Solid State Power Amplifiers
5RU Rack Height
Part Number Configuration Matrix
Power Level (Watts)
400, 500, 600, 800,
C-Band 1000 (10K),
1300 (13K)
250, 350, 500, 700,
X-Band
1000 (10K)
Ku-Band 200, 250, 400, 500
Band
C-Band C
X-Band X
Ku-Band K
1
Block Up Converter
M Internal Reference BUC
P External Reference BUC
X No BUC
Rack Height
5RU
5
P
L
Configuration Modifier 3
Standard (N+1 Power Supply)
N+1 P.S. + Rear Exhaust Adapters
HPA C 5 8 0 0 A R M X X X P
MODEL:
A1
B1
C
D1
H
L
R
S
T
Y
Z
Standalone Unit or System Package
Standalone amplifier
System with Cabinet, Top Mounted Waveguide Switching
System without Cabinet, Top Mounted Waveguide Switching
System with Cabinet, Rear Mounted Waveguide Switching
System without Cabinet, Rear Mounted Waveguide Switching
Frequency Sub Band
C-Band
X-Band
1
5.850 to 6.425 GHz
A 7.90 to 8.40 GHz
5.850 to 6.725 GHz
D 7.70 to 8.40 GHz
5.750 to 6.670 GHz
F 7.10 to 7.40 GHz
6.425 to 7.025 GHz
Ku-Band
5.715 to 5.790 GHz
1
14.00
to 14.50 GHz
A
4.400 to 5.000 GHz
B1 13.75 to 14.50 GHz
F1 12.75 to 13.25 GHz
G1 14.75 to 15.25 GHz
Configuration Modifier 2
X Standard
1
R1
Rx Band Reject Filter
V
Reflected Power Monitor
X-Band units only
Configuration Modifier 1
X Standard
S Input Sample Port
Available with optional BUC
X
A1
B
C1
D1
E
F
Standalone Unit or System Configuration
Standalone amplifier
1:1 System, Input Switching, Internal Control
1:1 System, Input Splitter, Internal Control
1:2 System, Input Switching, RCP2-12002
1:2 System, Input Switching, Internal Control
1:2 Phase Combined System, Input Splitter, FPRC-12002
1:1 System, Input Splitter, RCP2-11002
G 1:1 Phase Combined system, Input Splitter, FPRC-11002
H1 1:1 System, Input Switching, RCP2-11002
J 1:2 Phase Combined system, Input splitter, Internal Control
1 Switched input with external reference BUC requires reference distribution box.
2 Standard location for controller is directly above HPA1.
PAGE 7 OF 7
Example - A standalone 800W GaAs C-Band
5RU Rack Mount SSPA with standard N+1
external power supply and an optional internal
reference block up converter is part number:
HPAC5800ARMXXXP.
Use and Disclosure of Data
The information contained herein is classified as EAR99
under the U.S. Export Administration Regulations.
Export, re-export or diversion contrary to U.S. law is
prohibited.
Specifications are subject to change without notice.
214165 REV B ECO 18095
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement