XPress-Pro SW 52000 Quick Start

This quick installation guide describes how to install and use the hardened compact Ethernet Switch. Capable of operating at temperature extremes of

-10°C to +60°C, this is the switch of choice for harsh environments constrained by space.

Physical Description

The Terminal Block and Power Input

The Terminal Block

Earth Ground

DC Terminal Block Power Input: The DC Terminal Block power input can be used to power up this Switch.

The 10/100BaseTX and 100BaseFX Connectors

The 10/100BaseTX Connections

The following lists the pinouts of 10/100BaseT/TX ports.

Pin Regular Ports

1 Input Receive Data +

2

3

Input Receive Data -

Output Transmit Data +

4 NC

5 NC

6 Output Transmit Data -

7 NC

8 NC

The 100BaseFX Connections

The fiber port pinouts

The Tx (transmit) port of device I is connected to the Rx (receive) port of device II, and the Rx (receive) port of device I to the Tx (transmit) port of device II.

Uplink port

Output Transmit Data +

Output Transmit Data -

Input Receive Data +

NC

NC

Input Receive Data -

NC

NC

Number

May 2007

1

The Port Status LEDs

10/100TX or 100FX

LINK/ACT

Steady

Flashing

A valid network connection established.

LINK stands for LINK.

Transmitting or receiving data.

ACT stands for ACTIVITY.

‹

‹

‹

‹

‹

‹

Steady The port is transferring at 100Mbps.

100

Off

The port is transferring at 10Mbps If this

LED is dark.

Functional Description

‹ Support 802.3/802.3u/802.3x. Auto-negotiation: 10/100Mbps, Full/half-duplex; Auto MDI/MDIX.

100BaseFX: Multi mode SC and ST type; Single mode SC or ST type; WDM Single mode SC type.

Support 2K MAC addresses.

Store-and-forward mechanism.

Full wire-speed forwarding rate and non-blocking mechanism.

Broadcast storm filtering.

Operating voltage and Max. current consumption: 12VDC @ 0.71A, 24VDC @ 0.37A, 48VDC @ 0.22A. Power consumption: 10.56W Max.

‹ Power Supply: DC Terminal Block power input, 10-48VDC.

‹ Operating temperature ranges from -10 ℃ to 60℃.

‹ Plastic compact Din-rail industrial case design.

Assembly, Startup, and Dismantling

‹ Assembly: Place the switch on the DIN rail from above using the slot. Push the front of the switch toward the mounting surface until it audibly snaps

‹

‹ into place.

Startup: Connect the supply voltage to start up the switch via the terminal block.