Catalogue Sheet: Mini Retract-a

Catalogue Sheet: Mini Retract-a
Project/Location:
Mini Retract-a-Lite™
Series
Contractor:
Date:
Prepared by:
Unseen Solution the Next Generation
Features
Typical specifications
• Easy to retrofit in finished walls: the unit slides in through an
8.25” by 5.75” hole
Supply and install Emergi-Lite® Mini Retract-a-Lite™ Series. The
unit shall be designed to be completely concealed in walls with a
cavity. The equipment shall consist of a metal housing containing two
modules joined by a flexible bracket and electric conduit. One module
contains the battery, charger circuitry and electrical connection box;
the other module contains the emergency lights installed on the back
of a door able to rotate several turns of 360°. The unit equipment
shall be completely concealed in the wall after installation through a
rectangular opening not larger than 8.25” by 5.75”. In stand-by mode,
the only visible parts of the unit shall be the flat door and trim plate,
coated with a high-quality off-white finish that can be customized on
site with paint or other suitable wall covering. Upon a power failure
the unit will expose the emergency heads by rotating its door 180°
and then will power the lamps. At the restoration of the AC power
or at the end of the battery discharge, the lamps will turn off and
the unit will retract the heads by rotating the door 180° in the same
direction. The unit shall not require the presence of AC power in
order to close the door and conceal the lights. The door of the unit
shall be easy to force-turn (open or close) by hand, in any rotation
direction. The light source shall be 12V MR16 lamps of specified
technology, wattage and light output. The unit shall supply the rated
load for a minimum of 30 minutes or until the battery is discharged
to 87.5% of its nominal voltage (whichever duration is longer). The
charger circuitry shall utilize a micro-controller IC that samples
the battery in relation to the ambient temperature, state of charge,
and input voltage fluctuations. The charger shall be current limited,
temperature compensated, short-circuit proof, and reverse-polarity
protected. The circuit will charge in accordance with CSA C22.2
– 141 requirements. The unit shall be furnished with a recessed,
illuminated push button serving as test switch and status indicator
light. When specified, the unit shall come complete with the
Emergi-Lite® series of auto-test micro-controller circuitry to ensure
the equipment readiness and reliability by continuously monitoring
every critical function of the unit. If a component failure occurs, the
pilot light located on the front of the unit will change colour from
green to red and will flash indicating a fault. A detailed diagnostic
legend shall be available on the back side of the door and shall provide
fault identification (battery, charger circuitry, lamps) for maintenance
personnel. The auto-test shall simulate a power loss for one minute
monthly, 10 minutes every 6 months, and a full 30-minute test every 12
months.
The equipment shall be Emergi-Lite® model:
.
• No back-box needed to pre-install
• Input: Standard AC input 120/347VAC; optional 120/277VAC
• Output: 12VDC with up to 100W of power
• Battery: choice of sealed, maintenance-free Lead-Calcium
or Nickel-Metal Hydride
• Remote
capacity: can drive several wall or ceiling-mount 12VDC
remote Retract-a-Lite™ fixtures
• Charger: micro-controller driven, temperature compensated,
high precision, fast recharge
• Remote AC fixture: direct connection to 120 or 347VAC
power generators
• MR16 halogen lamps; power range from 12W to 50W, LED
4W and 5W
• Certification: CSA C22.2 No.141
Dimensions
Dimensions are approximate and subject to change.
31/2” [8.9 cm]
Complete Unit
175/8” [44.8 cm]
51/4” [13.2 cm]
7” [17.8 cm]
91/8” [23.2 cm]
Installed Unit
replacement lamps: MR16 type
model
lamp type
580.0080-E
MR16 Halogen
voltage/wattage
12V-12W
580.0064-E
MR16 Halogen
12V-20W
580.0083-E
MR16 Halogen
12V-35W
580.0076-E
MR16 Halogen
12V-50W
580.0068-E
MR16 High-lumen output
12V-20W
580.0090-E
MR16 High-lumen output
12V-35W
580.0089-E
MR16 High-lumen output
12V-50W
MRL80
120/347VAC
-
80
40
24
-
580.0093-E
MR16 LED
12V-4W
MRH100
120/347VAC
0.25/0.08 A
100
70
36
24
Power Consumption and unit rating
model
wattage capacity
30min 1h00 2h00 3h00
ac specs
580.0104-E
MR16 LED
12V-5W
MRG1
120VAC
Max. 0.95 A
Maximum 100W load
580.0106-E
MR16 LED
12V-6W
MRG2
277VAC
Max. 0.45 A
Maximum 100W load
MRG3
347VAC
Max. 0.35 A
Maximum 100W load
ORDERING INFORMATION
series
MR
powerpack
L80= Lead-Calcium,
12V-80W
H100= Nickel-Metal Hydride,
12V-100W
voltage
Blank=
120/347VAC
-2= 277VAC
Number of heads
/12= MR16, 2x 12W
/20= MR16, 2x 20W
/35= MR16, 2x 35W
/50= MR16, 2x 50W
/20H= MR16, High Lumen output, 2x 20W
/35H= MR16, High Lumen output, 2x 35W
/50H= MR16, High Lumen output, 2x 50W
LI= MR16 LED, 12V-5W
LG= MR16 LED, 12V-4W
LJ= MR16 LED, 12V-6W
EXAMPLE: MRL80/20HUN
101
options
U= auto-diagnostics*
UN= auto-diagnostics, non-audible*
D3= time delay (15 minutes)
*Minimum lamp load required: 20% of unit capacity
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement