6 - PAUSE PROGRAMMATION 1 - GENERAL DESCRIPTION

6 - PAUSE PROGRAMMATION 1 - GENERAL DESCRIPTION
6 - PAUSE PROGRAMMATION
1 - GENERAL DESCRIPTION
6A - MODIFICATION OF THE ACTIVATION TIME OF THE OUTPUTON CHANNEL 1
With this procedure you can determine how long the receiver will keep closed the contact
to channel 1 for timer mode.
Power on the receiver
and set Dip 5 to OFF
and Dip 6 to ON
Press the
button on the receiver
When the button is
released the green led
start flashing with
a second frequency
Set Dip 6
to OFF
The green led flashes
quickly to indicate
the modification
of the time
The time that you want
to set is the same that
you wait before
pushing again
the button
6B - MODIFICATION OF THE ACTIVATION TIME OF THE OUTPUTON CHANNEL 2
1A - PRODUCT DESCRIPTION
“NOVO RX” is a two channel output receiver compatible with "KING-gates " transmitters
with a"Hybrid" or "Master.way" codes (see Section 3 for the code setting).
It has two output channels "OUT1"and "OUT2" which can be set to operate as:
- Mono-stable: receiving the command the output is activated for a second
and then turns off
- Bi-stable: upon receiving the first command activates the output and receiving the second
command it deactivates output
- Timed: receiving the command the output is activated and remains active for a time
programmed from 1 second up to 245 seconds (programmable).
1B - TECHNICAL DATA
Power supply
Radio receiver
Absorption stand by/working
Relay contact
65
With this procedure you can determine how long the receiver will keep closed the contact
to channel 2 for timer mode.
Power on the receiver
and set Dip 5 to ON
and Dip 6 to ON
Press the
button on the receiver
When the button is
released the green led
start flashing with
a second frequency
Set Dip 6
to OFF
The green led flashes
quickly to indicate
the modification
of the time
The time that you want
to set is the same that
you wait before
pushing again
the button
Output
No. storable codes
No. outputs
Working temperature
12/24 Vac/dc
433.920MHz
22mA / 40 mA
0,5A @ 24Vac/dc
44
110
Relé
180
2
-20 / +55 °C
45
57
1C - INSTALLATION AND STARTING MODALITY
� For the timing of the contact of the output desired it must be set to timer mode
(see paragraph 4).
To install “NOVO RX” it is necessary to power the receiver and connect at least one output
contact OUT1 or OUT2 (see wiring diagram in section 2). After selecting the contact
function desired (see paragraph 4 DIP 1, 2 and 3, 4) according to the use of the commands
(see paragraph 1A) it is sufficient to program the remote controls that you want
to use (see paragraph 5).
FACTORY SETTING:
- Coding of "Hybrid" remote controls
- Output channel 1 bi-stable
- Channel 2 bi-stable
- Timing of the contact (if you change the type of output) is 30 seconds.
5 - RADIOTRANSMITTERS PROGRAMMING
2 - CONNECTION DRAWING
MEMORY
CARD
DIRECTION
SIGNAL LED
RADIO RECEIVER
DIRECTION
DIP
SWITCHES
It is possible to link the transmitters to the “OUT1” output contact by this procedure.
Power on the receiver
and set Dip 5 to OFF
and Dip 6 to OFF
Press the
button on the receiver
(the green led
switches on)
Make a transmission
pushing the desired
button on the
transmitter
Press the
button on the receiver
again to exit the
procedure (the green led
goes off)
Memorize all the
transmitters making a
transmission with the
desired button
During the insertion
the green led flashes.
When the code is
memorized the led
stays on
4
5
6
PROGRAMMING
BUTTONS
5A - PROGRAMMING OF A RADIO TRANSMITTER ON CHANNEL 1
RL2
3
RL1
0V
OUT1
12/24
VAC/DC
OUT2
1
ON
2
12-24
ANTENNA
SHIELD
ANTENNA
CARE
3 - SETTING CODE TYPE
This program allows you to set the code type of the transmitters between Master.way
(working only with transmitters with rolling code manageable with the palmtop programmer
"Prog MW) and Hybrid (working with all " KING-gates " transmitters).
Master.way coding: switch OFF power, set all dip-switches in ON and switch ON power .
The signal LED will flash three times to indicate "Master.way" mode activated.
Hybrid coding: switch OFF power , set all dip-switches in ON, press the program button,
and switch ON power. After releasing the button the signal LED will remain ON for three
seconds to indicate "Hybrid" mode activated.
� For normal functioning of the system at the end of the programming switch DIP 6
in OFF
� A different kind of code settings does not delete the radio codes
in the memory.
4 - DIP SWITCHES
DIP
01 02
03 04
05
06
STATUS
ON - ON
OFF - ON
ON - OFF
OFF - OFF
ON - ON
OFF - ON
ON - OFF
OFF - OFF
ON
OFF
ON
OFF
FUNCTIONING DESCRIPTION
OUT1 Timed relay (see paragraph 6)
OUT1 Monostable
OUT1 Bistable
OUT1 Not in use
OUT2 Timed relay (see paragraph 6)
OUT2 Monostable
OUT2 Bistable
OUT2 Not in use
Programming modality relay 2
Programming modality relay 1
Programming modality timed relay (see paragraph 6)
Standard functioning modality
5B - PROGRAMMING OF A RADIO TRANSMITTER ON CHANNEL 2
It is possible to link the transmitters to the “OUT2” output contact by this procedure.
Power on the receiver
and set Dip 5 to ON
and Dip 6 to OFF
Press the
button on the receiver
(the green led
switches on)
Make a transmission
pushing the desired
button on the
transmitter
Press the
button on the receiver
again to exit the
procedure (the green led
goes off)
Memorize all the
transmitters making a
transmission with the
desired button
During the insertion
the green led flashes.
When the code is
memorized the led
stays on
5C - DELETING OF ALL RADIO TRANSMITTER
Using this procedure the installer can delete all the previously programmed radio remote
controls from the memory
Power on the
receiver
Hold down button on the
receiver for 3 second
(the green led begins to
flash rapidly)
Press the button on the
receiver again to confirm
the cancellation
(cancellation is confirmed
by the flashing
becoming faster)
Was this manual useful for you? yes no