Chilled Water
System Solution
All Product Catalogue
AP-MSM-07A
Engineered for flexibility and performance.
™
CONTENTS:
Chilled Water System Solution
McQuay Offers ; Comprehensive Solution ........................ 2
In Air Conditioning Needs
Features Of McQuay Chilled Water Products ................... 3
Smart Manager ................................................................. 4
McQuay Air Cooled Mini Chiller Series ............................. 7
Tandem Compressors Air-Cooled Mini Chiller ................ 12
Inverter Mini Chiller ......................................................... 13
McQuay Chilled Water Fan Coil Units ..............................15
NIM & NIM PC Networking Control System .....................16
McQuay Chilled Water Fan Coil Units Range ..................17
Specification
Mini Chiller Specifications ............................................... S1
Chilled Water Fan Coil Unit Specifications ..................... S6
GLOBAL DISTRIBUTION NETWORK
Manufacturing Plant
Americas
• USA • Puerto Rico • Mexico • Paraguay • Uruguay • Guadaloupe •
Oceania
• Australia • New Zealand •
Middle East & Africa
• Jordan • Lebanon • Oman • Qatar • Saudi Arabia • Bahrain • Morocco • Morocco • Iraq • U.A.E. •
• Mauritius • South Africa • Kenya • Madagascar • Ghana • Nigeria • Tanzania •
Europe
• England • Greece • Hungary • Italy • Norway • Poland • Portugal • Russia • Spain •
• Belgium • Tunisia • Croatia • Cyprus • Lithuania • Yugoslavia • Malta • Slovenia • Ukraine •
• Turkey • Finland • Czech Republic • Romania •
Asia
• Cambodia • China • Hong Kong • Indonesia • Maldives •
• Malaysia • Singapore • Thailand • Vietnam • Pakistan •
Product Overview
Model Range
Cooling Capacity (kW)
Heating Capacity (kW)
Electrical Supply
R22
R407C
R410A
R410A Inverter
MAC 020/025/030 C/CR
M4AC 020/025/030 C/CR
M5AC 020/025 CR
M5ACV 030 CR
5.0 - 8.1
5.9 - 9.5
MAC 040/050/060 C/CR
M4AC 040/050/060 C/CR
M5ACV 055/075 CR
11.7 - 15.5
12.6 - 17.5
50Hz
60Hz
Model Range
Cooling Capacity (kW)
Heating Capacity (kW)
Electrical Supply
50Hz
60Hz
MWM 007/010/015/020 GW
MWM 301W
1.3-6.5
5.28-13.2
MCK 020/025/030/040/050 AW
2.4-11.7
14.1-19.6
Model Range
Cooling Capacity (kW)
Heating Capacity (kW)
Electrical Supply
50Hz
60Hz
MCM 007/010/015 CBW MCM 020/025/030/040/050 DW
1.9-3.1
5.9-13.2
4.0-7.2
10.3-24.9
MAC 080/100/120/150 C/CR
M4AC 080/100/120/150 C/CR
M5AC 030/040/050/055 CR
M5ACV 100/135 CR
21.6 - 40.5
26.4 - 38.7
7.3 - 14.9
9.8 - 18.0
MCK 020/025/030/040/050 AWH
3.8-5.2
9.8-12.7
MCK 015/020/025 BW
3.6-5.9
7.9-10.5
MCK 010/015/020 CW
2.6-5.0
4.4-7.6
MCC 010/015/020/025/028 CW
MCC 030/038/040/050/060 CW
2.9-15.8
5.6-32.2
MDB 075/100/125/150 BW
2.1-4.6
4.7-9.6
INTRODUCTION
McQuay Offers ;
Comprehensive Solution In Air Conditioning Needs
McQuay is committed to offer you with the best solution in your air conditioning needs. In the new series of chilled water products, McQuay is not just offering you with wide range of chilled water air conditioning equipments, but a comprehensive solution from selecting the equipments, designing the water piping systems to provide easy control of the complete chilled water system. This is facilitated by the user friendly computer selection programs and remote monitoring of the operation of complete system through the Smart Manager.
The series of chilled water product has incorporated the technology of advanced communicating controls, microprocessor controlled chillers with a wide range and variety of fan coil unit that offers total flexibility, high technology and quality that will always meet your air conditioning demands.
2
McQuay Chilled Water Series Of Products
FEATURES
Year Round Comfort
Can be used in variety of climates with systems that are available in two versions, cooling only and heat pump.
Reliable, Precise and Efficient
The refrigerant of the system is confined to within the chiller itself and therefore no refrigerant is circulating throughout the building. This will be no risk of refrigerant leakages in building or risk of poor oil return that will damage compressor caused by poor installation.
Multiple compressors in McQuay chiller series offers stages capacity control that will offer better efficiency.
Long Piping Applications
McQuay chilled water system avoids the limitation of piping lengths and bends that exist in Direct
Expansion refrigerant system. The chiller can be installed far away from the fan coil units, thus offering flexibility and creativity in the installation.
Quality, Innovative and Compact
Design
McQuay chiller is designed fully equipped with reliable and quality components that are sourced from major well known supplier in the world.
Multiple Temperature Zone Control
The operation of the fan coil units can be managed independently by zones according to similar air conditioning comfort needs.
3
Controller
By adopting the McQuay chilled water system, the comfort in residential and light commercial buildings such as offices, hospital, restaurant, hotel and shopping complex can be controlled and managed from just one point, that is through the Smart Manager.
The Smart Manager is acting as a center to manage the operation of both the chilled water fan coil units and the chillers.
Besides allowing the user to have customized control for each connected unit, the Smart Manager is also able to manage the overall system operating mode of all units based on the air conditioning system load demand of the building.
FEATURES
Supported Up To 50 Chillers &
120 Fan Coil Units
Through the versatile Smart Manager controller, the operation of each equipments in the McQuay chilled water system connected through the chiller Bus and McQuay own proprietary NIM BUS can be managed and controlled.
Chiller Network BUS
4
Fan Coil Network BUS
Display Up To 46 Types Of Chiller Fault/Alarm And 6
Types Of FCU Fault/Alarm
Whenever a fault occurred in either the chiller or fan coil unit, a signal will be sent to Smart Manager and an alarm message will appear on the LCD, showing type of alarm, alarm occurred time, date and unit.
This will greatly ease the troubleshooting process and thus reduce the valuable time of service technicians.
As soon as the fault is being solved, the alarm will automatically dissolve from the LCD.
Alarm 1
Comp 1 overload
01/01/00
(Ch 0)
12.00am
Priority Settings
Depending on the application requirement, the Smart Manager offers the flexibility to allow user to set the priority on the operation of fan coil unit and chiller in a complete McQuay chilled water product system.
If priority is set to Fan Coil Unit, the chiller will be forced to OFF if all fan coil units are OFF. If Chiller Priority is being set, all fan coil units will be OFF if chillers are OFF.
Threshold Value Setting
If the priority setting is being preset to fan coil unit, the operating mode of the complete McQuay chilled water system can be synchronized to operate under one same mode. This is achievable through the unique feature called
“Threshold Value Setting”
Smart Manager can command chiller operating mode to switch from current operating mode if the threshold value is meet.
Example,
In a network of 10 fan coil units that is currently operating in COOL mode and a threshold of 60% was set for COOL mode and threshold of 50% was set for HEAT mode. Should 6 of the fan coil units are requesting for HEAT mode then the threshold for HEAT is crossed. Signal will be sent by Smart Manager to chiller BUS to switch the operating mode of all chillers to HEAT mode. Requirement of users will be met.
• Heat Treshold •
Chiller to operate at Heat Mode
0 1 2 3 4 5 6 7 8 9 10
Chiller to operate at Cool Mode
• Cool Treshold •
5
Energy Saving Programmable
Timer
The operation of the chiller and each fan coil unit can be preset to operate and to stop at different time schedule and at different day of a week. Taking consideration of the fact that certain rooms in a building will be empty at certain period of the day, setting timer to On and to Off the operation of units in those areas will greatly reduce the energy cost of the building.
At the same time, Smart Manager allows setting up to five sets of 7 days programmable operating schedules
(2 On/Off timer per day) for each fan coil unit.
HOLIDAY SETTINGS
Holiday 1
Holiday 2
Holiday 3
Holiday 4
Holiday 5
Set Holiday 1
Month
Day
: 1
: 1
Duration : Disable
MCC
MCK
MCM2
MCM1
MWM
Time
Holiday Setting
While designing the Smart Manager, the practical aspects of equipment application were always the key points to be considered. Thus resulting in the creation of “Holiday Setting” feature.
In this feature, users are allowed to set up to 10 holiday timers with each timer can last for duration of 99 days.
During the duration of Holiday Timer set earlier, all fan coil units and chiller will automatically be turned Off.
6
MCC
MCK
MCM 2
MCM 1
MWM
Memory Backup (EEPROM), Alarm
Memory for Chiller and FCU
When there is power failure occurs during operation, Smart Manager will load the last state memory from EEPROM after power On reset.
Besides, extra memory space inside the Smart
Manager will allow user to view the previous alarm records even though its have been dissolved. This useful information will benefit the service technician to view the history of maintenance record done to the unit.
Password Protection For Advanced
Parameter Settings (Chiller)
A McQuay chilled water product system with key parameters that were set by experience professionals to optimize operating conditions will need to be protected against any unauthorized disturbance or changes. The built in “Password
Settings” feature will prevent the losing of key parameter settings in the Smart Manager and ensure the users that they will continue to enjoy the comfortable environment.
Low Power Mode (Chiller + FCU)
Smart Manager will turn into low power mode during electricity power breakdown. It will operate based on the built in backup battery and only one timer and interrupt is active. CPU operation is Off and no display on LCD as well for energy saving purpose.
Key Parameter Display
For easy serviceability and maintenance, Smart
Manager is able to display the key parameter such as defrost and compressor discharge sensor temperature, water in/out temperature, status of compressor On/Off, Cool/Heat mode water in temperature, etc. Thus, it reduces the cumbersome of requiring the service technicians to physically go to site of chiller installation to do the troubleshooting process.
Accumulative Compressor Run
Time
User can also check the compressor run time of chiller in Smart Manager. It will provide a guideline as well as posting a reminder for requirement of routine system service.
Multiple Temperature Zone Control
The operation of the fan coil units can be managed independently by zones according to similar air conditioning comfort needs.
Real Time Clock (RTC)
RTC will always appear at the summary pages and the user is able to set the time and date.
7
McQuay Air Cooled Mini Chiller Series
McQuay offering you the range of air cooled chiller that is suitable for many applications from residential to commercial.
The McQuay chiller is incorporated with all the necessary components such as circulating water pump, expansion tank, compact brazed plate heat exchanger, differential pressure switch and the microprocessor controller and wired control panel.
8
In addition, the selection of the McQuay chiller could not be more easy than the user friendly yet versatile selection softwares for chiller as well as connecting piping.
In short, Smart Manager Chilled Water Product
Range offers you the all-in-one solution to your chilled water product needs.
Smart Manager air cooled chiller makes your life easy.
McQuay is participating in
EUROVENT certification program
PRODUCT RANGE
Model :
MAC 020/025/030 C/CR
M4AC 020/025/030 C/CR
M5AC 020/025 CR
M5ACV 030 CR
Capacity :
Cooling : 5 kW to 8.1 kW
Heating : 5.9 kW to 9.5 kW
Refrigerant : R22, R407C, R410A
Model :
MAC 040/050/060 C/CR
M4AC 040/050/060 C/CR
M5ACV 055/075 CR
Capacity :
Cooling : 11.7 kW to 15.5 kW
Heating : 12.6 kW to 17.5 kW
Refrigerant : R22, R407C, R410A
Model :
MAC 080/100/120/150 C/CR
M4AC 080/100/120/150 C/CR
M5ACV 100/135 CR
Capacity :
Cooling : 21.6 kW to 40.5 kW
Heating : 26.4 kW to 38.7 kW
Refrigerant : R22, R407C, R410A
9
Model :
M5AC 030/040/050/055 CR
Capacity :
Cooling: 7.3 kW to 14.9 kW
Heating: 9.8 kW to 18.0 kW
Refrigerant : R410A
FEATURES
Compactness
The MAC/M4AC 020~030 C/CR is such a compact unit that it can be integrated perfectly with any architectural design, making it an ideal choice for house, offices, restaurant and shop.
Scroll Compressor
Scroll Compressors are used for the units to offer a quiet and reliable performance over a wide operating temperature range. (Except MAC/M4AC
020 C/CR which uses rotary compressor).
For MAC/M4AC 030, 040, 050, 060, 080, 100, 120,
150 CR, phase protector is provided to prevent the compressor from rotating in the wrong directions.
Fully Equipped Chillers
McQuay chiller is fully integrated and equipped with key hydronic components such as expansion tank, water tank, brazed plate heat exchanger and water circulating pump. The all in one concept will ease the job of installer.
Brazed Plate Heat Exchanger
The heat exchanger is made of AISI 316 stainless steel plates closely arranged and brazed together to ensure high heat exchange efficiency.
10
Microprocessor Control
McQuay chillers are equipped with microprocessor controller that will control and regulate the operation of the unit.
Besides, the controller that contains the well developed algorithm will provide protection to the chiller by accurately sensing the key temperatures in both the water and refrigerant circuit. Should there be any abnormal reading received by controller, an alarm signal will be sent to chiller panel, followed by protection action plans such as to stop the operation of compressor, condenser fan motor or circulating water pump.
Partial Loading
Models MAC/M4AC 080~150 C/CR has been designed with two separate refrigerant circuits, i.e. it has two compressors. By doing so, the unit has part loading capabilities, i.e. 0-50-100% of rated capacity. This will improve the reliability and energy efficiency of the unit, especially during low loading operations.
Availability Of Connection To
Boiler
The microprocessor controller has a built in control algorithms that allowed the chiller to be connected to the boiler. By adding a boiler to the system, it can either work as the sole heating water source in a
Cooling only unit or it can act as the booster heat source to the Heat Pump chiller.
Safety Protection
The safety protections provided for the McQuay chiller are:
• High & Low Pressure Switches
• Anti-Freeze Protection Sensor
• Discharge Temperature Sensor
• Over Pressure Relief Valve
• Water Pressure Differential Switch
• Anti-Freeze Heater on BPHE
• Compressor Water Pump &
Fan Motor Overload Protector
Anti-Freeze Protection
The chiller unit has several anti-freeze protection features:
1. Built-in heater in BPHE
The BPHE has a strip heater around it to prevent water freezing inside.
2. Anti-Freeze sensor
BPHE can avoid the frosting as the antifreeze sensor will send the signal to cut out the compressor if the water temperature becomes too cold.
3. Water pressure differential switch
This protection feature will ensure there is water flow in pipings when the chiller is in operation. Otherwise, the compressor will cut out immediately.
Sequencing Control
For MAC/M4AC 080~150 C/CR, both compressors will cut in and cut out depending on their accumulative operating time. This sequencing control feature will ensure no single compressor is overload in operation as well as to ensure longer reliability of compressors.
Chiller Bus
Modular Installation
The mini chillers are available for modular connection. A network of up to 50 chillers in a system is possible. Control on the operation of the chillers will be done through the microprocessor controller. The external water piping connection can be made either from the left or right side of the unit.
Water In Water Out
Up to 50
Chillers
11
FEATURES
Easy Installation And Maintenance
As a chiller, all hydronic components are assembled and wiring jobs on chillers are done and tested in the factory. Thus, there is no need for installer to select for the component again on site.
In addition, unit operation is user friendly and maintenance is simple. By opening the front panel, you would have immediate assess to all components.
Factory Precharged Refrigerant
Each heat exchanger in the chiller is brazed and tested against leakages through dried air at 30 bars.
After that, another process to vacuum the system before accurately charged with refrigerant to ensure optimum performance. Thus, it saves the hustles of field charging by installers.
Anti Corrosion Heat Exchanger
The condenser heat exchanger of chiller, heat pump specification, utilize the special anti corrosion gold aluminum fin.
Zero Ozone-Depleting Potential
Refrigerant
In line with Montreal Protocol on encouragement of more usage of Zero Ozone-Depleting Potential refrigerant, McQuay chiller is available in R407C &
R410A series.
Brazed Plate Heat Exchanger
The heat exchanger is made of AISI 316 stainless steel plates closely arranged and brazed together to ensure high heat exchange efficiency.
Chiller Control Panel
The chiller panel controller is designed to control the chiller operation. This device allows the user to have customized control for each connected unit.
Each chiller will have a chiller control panel that comes as a standard accessory. At the same time, the chiller control panel is able to be installed remotely through the cable up to a distance of 100 meters. Example, the chiller panel can be installed in a centralized plant control room for the building.
The chiller control panel has been designed taking into consideration of the user friendly and yet versatile control features.
Features:
• Whole system configuration.
• Unique parameter settings.
• Operation status display.
• Tracing fault record (offer quick troubleshooting solutions).
• The display is shown in an 8-lines graphical LCD display. There are 8 dedicated keys available in the panel.
• Menu selection.
• Navigation on the screen.
• Modification of the selected value.
12
Air - Cooled Mini Chiller
This new line of innovative air cooled chiller by McQuay was designed with one purpose in mind, which is to offer user with cost and energy saving for users.
High Seasonal Efficiency
• Usage of high efficient R410A rotary compressors in tandem configuration
• Extremely tight tolerances between moving parts resulting in high compressor volumetric efficiency
• Minimize mechanical losses
• Minimize gas flow losses and turbulence
• Optimize compressor oil return
Capacity Step Control
• 3 steps compressor loading (0%-40%-60%-100%) for M5AC 040 CR & M5AC 050 CR
• 2 steps compressor loading (0%-50%-100%) for
M5AC 030 CR & M5AC 055 CR
Sequential Control
• Both compressors will cut in cut out depending on water temperature. This is definitely improving the compressor life cycle as well as the compressor reliability.
Elimination of Water Tank
• Combining the Tandem Compressors technology with the algorithm of the microprocessor control, water tank can be eliminated in most instances.
Choices of Single Phase and 3
Phase Power Supply Connection
• Usage of single phase power supply compressors and circulating water pump.
• Offers flexibility to field installation.
13
The new series of Inverter Mini Chillers are specially designed / developed to achieve better system energy saving as well as towards perfect control during part load condition.
True Dual Circuits BPHE
Apply sophisticated technology of true dual circuit
BPHE.
The true dual BPHE puts the secondary circuit
(water) in contact with 2 primary circuits
(refrigerant). So even if one primary circuit is shut off, each secondary channel is still in contact with a primary channel. These advantages have made the product the natural choice for flexible chillers, climate control applications and high-precision systems food cooling cabinets in supermarkets.
Ref.1
Ref.2
Ref.1
Ref.2
Ref.1
water water water
Inverter Compressor
water
Inverter compressor is programmed to run at the optimum speed, which is regulated by the input frequency as it can varies according to the heat load requirement.
Water In
Primary
Circuit 1
Primary
Circuit 2
Water Out
Built In Fan Speed
Fan speed is now controlled by the built in algorithm, resulting in cost saving since installation of external FSC (Fan Speed Controller) can be exempted. It is regulated at 100%, 70% and 50% based on the ambient and outdoor condensing temperature.
Safety Protection
• High & Low Pressure Switches
• Anti-Freeze Protection Sensor
• Discharge Temperature Sensor
• Over Pressure Relief Valve
• Water Pressure Differential Switch
• Anti-Freeze Heater on BPHE
• Compressor, Water Pump Overload Protector
Anti Corrosion Heat Exchanger
Gold Aluminum fin is offered as the standard material of the condenser heat exchanger of this series of chiller.
14
Room
Temperature
Set
Temperature
Precise & Stable Temperature Control
Time
Room
Temperature
Set
Temperature
Inverter System
Fast Cooling
Time
Conventional System
Advantages of inverter compressor applications are:
LESS START & STOP
Frequency regulated compressor resulting in lesser in the sense of start and stop of compressor, which is greatly reduce the energy consumption.
FAST COOLING / HEATING
Unlike the other conventional systems, inverter compressor has the ability to produce faster cooling / heating capacity at the frequency higher than the dominant capacity frequency.
SMART LOADING / UNLOADING
With the integration of built in system algorithm; inverter compressor could control the system loading and unloading sophisticatedly.
BETTER COMPRESSOR RELIABILITY
Reliability of inverter compressor is always better since there is lesser ON/OFF of the system especially during the low load condition.
LOW STARTING SURGE
Inverter compressor require lower starting torque and thus, resulting in lower starting current.
Elimination Of Water Tank
Inverter system provide constant water temperature band, or much lesser water temperature fluctuation.
With this, water tank of the mini chiller system can be eliminated.
15
High Cooling ESEER And Heating
COP
The ability of the compressor to regulate at different frequency has lead to the outstanding figure in term of Cooling ESEER as well as the Heating COP of the inverter mini chiller.
Cooling SEER of Inverter Mini Chiller
12
10
8
6
4
2
0
5ACV30CR 5ACV55CR 5ACV75CR 5ACV100CR
Model
5ACV135CR 5ACV210CR
Heating COP of Inverter Mini Chiller
4.00
3.00
2.00
1.00
0.00
5ACV30CR 5ACV55CR 5ACV75CR 5ACV100CR
Model
5ACV135CR 5ACV210CR
Modular Installation
A network up to 50 chillers in a system is possible.
Control on the operation of the chillers will be done through the microprocessor controller. The external water piping connection can be made either from the left or right side of the unit.
Chiller Panel Comes As
The Standard Controller
Compatible With
Smart Manager
McQuay Chilled Water Fan Coil Units
To complement the new innovative Smart Manager range of air cooled chillers, McQuay is offering an extensive range of chilled water fan coil units that will meet any indoor application requirements covering residential, light commercial and commercial.
The aesthetically attractive decorative fan coil units such as Wall Mounted models, Ceiling Cassette and Ceiling
Convertible is compact and ergonomic, the ranges can blend in easily to any interior designs whether it is residential houses, office, restaurant or shops.
In addition, the McQuay chilled water fan coil units are designed with easy installation and easy servicing in mind.
The fan coil units also include the microprocessor controller that has built in algorithm to control the operation of the fan coil unit as well as to provide protection to the unit.
16
NIM Networking Control System (optional)
For multiple fan coil unit installation in an office, a centralised controlled operation can be achieved through the
McQuay proprietary NIM networking system.
Network Interface Module (NIM) is a networking system which enables communication among McQuay air conditioners.
With the NIM, all your air conditioning systems can be controlled with just a single controller giving you boundless benefits:
BENEFITS
• Ultimate convenience. No more individually controlling air conditioning units
• Quick and easy zone control from the master control unit
• Better control of air conditioning systems operating conditions
NIM utilizes master-slave type system whereby the master node will issue commands to each of the slave nodes.
NIM
For NIM PC only
NIM
NIM NIM NIM
NIM NIM NIM NIM
NIM PC for Global Control Hub
With NIM PC, a personal computer will act as a centralised unit for both controlling and monitoring of all the air conditioning units in the HydroNIM network.
For controlling, settings can be set from the PC and send out to the system for execution. While for monitoring, there is a graphical user interface for displaying the status of each unit.
The NIM PC provides a Global Control Hub that offers comprehensive control for better system management:
• Easy to operate full graphical user interface.
• Control online units globally, as a group, or as individual units.
• Configure a super master unit.
• Support up to 42 On/Off timers per week.
• Real time monitoring of online units.
• Error diagnostic and alerting features for all units.
• Data logging and printing ability.
• Database to store unit location.
• Login protected by password.
17
McQuay Chilled Water Fan Coil Units Range
Wall Mounted Range
MWM 07/10/15/20/25 GW
Features :
• Slim and compact
• Wide capacity range
• Wide air flow range
• Incorporated with NanoGuard which effectively inactive
& eliminate various harmful airbone elements.
• Able to communicate with the versatile NIM for fan coil units networking
• Light weight
• Detachable and washable air intake grille
• Microprocessor control
• Self diagnosis features
• Automatic air swing
• Wireless Control as standard
• Mode selection, fan speed, 24 hours real timers
• Optional wired controller
STANDARD
WM-GW WM301W
OPTIONAL
MWM 301 W
Ceiling Cassette Range
MCK 010/015/020 CW
MCK 015/020/025 BW
2 Pipes System:
MCK 020/025/030/040/050 AW
4 Pipes System:
MCK 020/025/030/040/050 AWH
G11 Wireless
Controller
G6 Wireless
Controller
SLM
Wired Controller
AC-5300
Wireless
Controller
Features :
• 3 range of ceiling cassette to be chosen from.
- MCK-CW - 570mm (w) x 570mm (l)
- MCK-BW - 650mm (w) x 650mm (l)
- MCK-AW - 820mm (w) x 820mm (I)
• Aesthetically attractive and slim front panel
• 4 way air discharge to provide better air distribution to room
• Automatic air swing
• 4 pipes system is available for model
MCK020/025/030/040/050AWH
• Easy servicing and maintenance
• Built in high pressure head drain pump
- Ability to pump up condensate water to 700mm high
• Built in water float switch to protect the unit from problems of condensate water overflow
• Microprocessor control
• Able to communicate with the versatile NIM for fan coil units networking
• Self diagnosis feature
• Wireless Control as standard
- Mode selection, fan speed, 24 hours real timers
• Optional wired controller
STANDARD OPTIONAL
G7 Wireless Controller Netware III Wired Controller
18
Ceiling Convertible Range
MCM 007/010/015 CBW
MCM 020/025/040/050 DW
Features :
• Ceiling Convertible feature offers flexibility on installation
- Installation method of under ceiling or floor standing
• 2 way air discharge ensure better air distribution
- Horizontal air throw and bottom air throw
• Automatic Air swing
• Aesthetically attractive with round profile outlook fits into to any indoor architectural
• Strong air flow volume and strong air throw distance makes it a perfect choice for light commercial such as restaurant and shop
• Microprocessor control
• Able to communicate with the versatile NIM for fan coil units networking
• Self diagnosis feature
• Wireless Control as standard
- Mode selection, fan speed, 24 hours real timers
• Optional wired controller
STANDARD OPTIONAL
MCM 15/20/25 EW G7 Wireless
Controller
SLM
Wired Controller
AC-5300
Wireless
Controller
Ceiling Concealed Range
MCC 010/015/020/025/030/040/050/060 CW
Features :
• Wide capacity range
• 4 speed fan motor offers flexibility for installation to suit application
- Each speed will offer different external static pressure and air flow
• High External Static Pressure is available up to 18mm
• Extra secondary drain pan to provide protection against condensate water leaking
• Availability of various optional duct accessories specially designed to fit to MCC-CW range
• Microprocessor control
• Filter adaptor kit of 1 inch is available as optional accessory
• Able to communicate with the versatile NIM for fan coil units networking
• Self diagnosis feature
• Wired Control as standard
- Mode selection, fan speed selection
STANDARD OPTIONAL
MCC 028/038 CW
SLM Wired Controller Netware III Wired Controller
19
Ceiling Concealed Range
2 Pipes System:
MCW 200/300/400/600/800/1000/1200 C
4 Pipes System:
MCW 200/300/400/600/800/1000/1200 CH
Features :
• Wide capacity range
• Multiple rooms can be cooled by just 1 unit of MCW
• Simple design with easy serviceability feature
• Extremely low height of unit – 251mm for complete range
• Water piping connection can be easily converted from one side to the other
• Fan motor assembly is not cased, allowing free return or back return or bottom return with optional return plenum
• Availability of optional extended drain to receive the condensate water dripping from the water piping connection
• Availability of 4 pipes MCW series
• Other optional accessory available:
- Wired thermostat
- Choice of external static pressure (ESP)
- Four types of ESP are available: 0Pa, 30Pa, 60Pa, 80Pa.
- PTC (Positive Temperature Coefficient) electric heater
- 2 way & 3 way valves
Ducted Blower Range
Features :
• These units are design with high air flow and high external static pressure, enables adequate distribution of air to the desired space
• Multiple rooms can be cooled by just 1 unit of MDB
• Simple design with easy serviceability feature
• The robust unit is designed with durability and reliability in mind
• MDB125/150BW is using the belt driven fan motor and blower fan thus it offers flexibility for upgrading should higher air flow is required
• MDB150BW is designed to cater for either horizontal air discharge or vertical air discharge
MDB 075/100/125/150 BW
Return Bracket Assembly come with Adaptor
(MCC 010CW - 1 outlet; MCC 015~020CW - 2 outlets)
Adaptor
Discharge and Return
Y-Joint
Return Grille Assembly come with Adaptor
Supply Grille Assembly come with Adaptor
(Front View) (Side View) (Front View)
Optional Accessories (MCC010CW~MCC025CW)
20
AC8000C Series
RS485
FCU
AC80000A
Smart Manager
AC80000C
NIM PC
AC8000C FCU
OR
AC8000C FCU
More FCUs
AC8000C
LCD Panel LCD Panel LCD Panel
A new developed thermostat series, AC8000 is now available to be ordered as Chilled Water Fan Coil unit controller, inclusive of
AC8000A and AC8000C. Its adopt micro-computer technology and is designed for the ease of installation, low power consumption as well as towards precise operation.
AC8000A practises the most simple and conventional installation method where it consists of a wired controller and a power board. Both of its are attached together while being installed.
Same with AC8000A, AC8000C also consist of a wired controller and a power board, but the power board is attached to the fan coil unit while the wired controller will be installed away from it. Moreover AC8000C has the networking capability, with compatibility to the
Network Interface Module (NIM); better control over whole operating system can be achieved as it offers quick and easy zone control from the master operating unit.
Features :
• Four Operating Modes
COOL/ FAN/ HEAT/ AUTO
• Variable Indoor Fan Speed Selection
High/ Medium/ Low/ Auto
• Selectable Function
Cooling Only, Cooling and Heating (2 pipes), Cooling and Heating (4 pipes)
• LCD display
• LED Indication of Power Supply
• 7 days Programmable Timer
• Real Timer
• Selectable Room Temperature/ Set Temperature Display
• Temperature Control Precision up to +/- 1 °C
• High, Low Voltage Separated for Safety
• Last State Memory Backup
• Networking Capability (Only Applicable for AC8000C)
AC8000C is compatible with Smart Manager and NIM PC. By using a RS485 cable, it can easily form a NIM bus as described in schematic diagram.
21
Mini Chiller Specifications
MAC020C - MAC060C (Cooling Only, R22)
MODEL
NOMINAL COOLING CAPACITY
Btu/h
W
W
V/Ph/Hz
NOMINAL TOTAL INPUT POWER
POWER SOURCE
REFRIGERANT TYPE
CONTROL
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
SOUND PRESSURE LEVEL
EVAPORATOR
NOMINAL WATER FLOW
HYDRAULIC KIT
MAX. WATER OPER. PRESSURE
PUMP
WATER FLOW RATE
PIPING
INSTALLATION PIPE CONNECITON
HEAD
MATERIAL
TANK
CAPACITY/VOLUME
COMPRESSOR
STAGE OF CAPACITY CONTROL (Btu/h) mm/in mm/in mm/in kg/lb dBA l/s/m 3 /hr kPa/psi l/s/m 3 /hr mm/in m
L/ft 3
MAC020C
18000
5275
2669
116 / 256
57
0.25 / 0.9
0.25 / 0.9
8.4
MAC025C
23500
6887
2730
220-240 / 1 / 50
800 / 31.5
1160 / 45.7
460 / 18.1
123 / 271
57
0.33 / 1.2
0.33 / 1.2
9.7
22 / 0.78
MAC030C
27500
8059
3491
R22
CAPILLARY TUBE
MAC040C
40000
11723
4470
128 / 282
58
0.39 / 1.4
195 / 430
60
0.56 / 2.0
1000 / 145
0.39 / 1.4
0.56 / 2.0
25.4 / 1
8.8
9.2
CAST IRON / STAINLESS STEEL
0 - 100%
MAC020CR - MAC060CR (Heatpump, R22)
MODEL
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER
COOLING
HEATING
POWER SOURCE
REFRIGERANT TYPE
CONTROL
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
SOUND PRESSURE LEVEL
EVAPORATOR
NOMINAL WATER FLOW
COOLING
HEATING
HYDRAULIC KIT
MAX. WATER OPER. PRESSURE
PUMP COOLING
WATER FLOW RATE
HEATING
INSTALLATION PIPE CONNECITON
PIPING
HEAD
COOLING
HEATING
MATERIAL
TANK
CAPACITY/VOLUME
COMPRESSOR
STAGE OF CAPACITY CONTROL (Btu/h)
Btu/h
W
Btu/h
W
W
W
V/Ph/Hz mm/in mm/in mm/in kg/lb dBA l/s/m l/s/m
3
3
/hr
/hr kPa/psi l/s/m 3 /hr l/s/m 3 /hr mm/in m m
L/ft 3
MAC020CR
18000
5275
22000
6448
2599
2770
116 / 256
57
0.25 / 0.9
0.31 / 1.1
0.25 / 0.9
0.31 / 1.1
8.4
6.9
MAC025CR
23000
6740
25000
7327
2779
2614
220-240 / 1 / 50
800 / 31.5
1160 / 45.7
460 / 18.1
123 / 271
57
0.32 / 1.2
0.35 / 1.3
0.32 / 1.2
0.35 / 1.3
9.9
9.4
22 / 0.78
MAC030CR
27500
8060
31500
9232
3541
3561
58
R22
MAC040CR
40000
11723
43000
12602
4560
4629
CAPILLARY TUBE
128 / 282
0.39 / 1.4
0.44 / 1.6
0.39 / 1.4
0.44 / 1.6
1000 / 145
0.56 / 2.0
0.60 / 2.2
25.4 / 1
8.8
7.9
9.2
8.1
CAST IRON / STAINLESS STEEL
0 - 100%
Notes:
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 12ºC / 7ºC ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 35ºC AIR AMBIENT TEMPERATURE.
b) HEATING - 40ºC / 45ºC ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 7ºC AIR AMBIENT TEMPERATURE.
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND
1m BELOW THE UNIT.
195 / 430
60
0.56 / 2.0
0.60 / 2.2
MAC050C
50000
14654
5245
380-415 / 3 / 50
1410 / 55.5
1160 / 45.7
460 / 18.1
196 / 432
60
0.70 / 2.5
0.70 / 2.5
6.8
40 / 1.41
MAC050CR
46000
13481
52000
15240
5046
4999
380-415 / 3 / 50
1410 / 55.5
1160 / 45.7
460 / 18.1
196 / 432
60
0.64 / 2.3
0.73 / 2.6
0.64 / 2.3
0.73 / 2.6
8.2
6.0
40 / 1.41
MAC060C
53000
15533
6361
203 / 448
61
0.74 / 2.7
0.74 / 2.7
6.6
MAC060CR
53000
15533
59000
17292
6551
6247
203 / 448
61
0.74 / 2.7
0.83 / 3.0
0.74 / 2.7
0.83 / 3.0
6.6
4.0
S1
Mini Chiller Specifications
M4AC020C - M4AC060C (Cooling Only, R407C)
MODEL
NOMINAL COOLING CAPACITY
Btu/h
W
W
V/Ph/Hz
NOMINAL TOTAL INPUT POWER
POWER SOURCE
REFRIGERANT TYPE
CONTROL
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
SOUND PRESSURE LEVEL
EVAPORATOR
NOMINAL WATER FLOW
HYDRAULIC KIT
MAX. WATER OPER. PRESSURE
PUMP
WATER FLOW RATE
PIPING
INSTALLATION PIPE CONNECITON
HEAD
MATERIAL
TANK
CAPACITY/VOLUME
COMPRESSOR
STAGE OF CAPACITY CONTROL (Btu/h) mm/in mm/in mm/in kg/lb dBA l/s/m 3 /hr kPa/psi l/s/m 3 /hr mm/in m
L/ft 3
M4AC020C
21000
6154
2617
116 / 256
57
0.29 / 1.0
0.29 / 1.0
7.3
M4AC025C
23000
6740
2949
220-240 / 1 / 50
800 / 31.5
1160 / 45.7
460 / 18.1
123 / 271
57
0.32 / 1.2
0.32 / 1.2
9.9
22 / 0.78
M4AC030C
27000
7912
3679
R407C
CAPILLARY TUBE
M4AC040C
40000
11723
4910
128 / 282
58
0.38 / 1.4
195 / 430
60
0.56 / 2.0
1000 / 145
0.38 / 1.4
0.56 / 2.0
25.4 / 1
8.9
9.2
CAST IRON / STAINLESS STEEL
0 - 100%
M4AC020CR - M4AC060CR (Heatpump, R407C)
MODEL M4AC020CR M4AC025CR M4AC030CR M4AC040CR
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
Btu/h
W
Btu/h
W
W
W
V/Ph/Hz
17000
4982
20000
5861
2597
2685
22000
6448
25500
7474
3076
2745
220-240 / 1 / 50
25000
7327
32500
9525
3804
4004
40000
11723
45000
13188
4820
4994
NOMINAL TOTAL INPUT POWER
COOLING
HEATING
POWER SOURCE
REFRIGERANT TYPE
CONTROL
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
SOUND PRESSURE LEVEL
EVAPORATOR
NOMINAL WATER FLOW
COOLING
HEATING
HYDRAULIC KIT
MAX. WATER OPER. PRESSURE
PUMP
PIPING
WATER FLOW RATE
COOLING
HEATING
INSTALLATION PIPE CONNECITON
COOLING
HEAD
HEATING
TANK
MATERIAL
CAPACITY/VOLUME
COMPRESSOR
STAGE OF CAPACITY CONTROL (Btu/h) mm/in mm/in mm/in kg/lb dBA l/s/m l/s/m kPa / psi l/s/m 3 /hr l/s/m 3 /hr mm/in m m
L/ft
3
3
3
/hr
/hr
116 / 256
57
0.24 / 0.9
0.28 / 1.0
0.25 / 0.9
0.31 / 1.1
8.7
7.7
800 / 31.5
1160 / 45.7
460 / 18.1
123 / 271
57
0.31 / 1.1
0.36 / 1.3
0.32 / 1.2
0.35 / 1.3
10.1
9.3
CAST IRON / STAINLESS STEEL
22 / 0.78
58
R407C
CAPILLARY TUBE
128 / 282
0.35 / 1.3
0.46 / 1.7
0.35 / 1.3
0.46 / 1.7
1000 / 145
0.56 / 2.0
0.63 / 2.3
25.4 / 1
9.4
7.6
9.2
7.5
CAST IRON / STAINLESS STEEL
0 - 100%
Notes:
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 12ºC / 7ºC ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 35ºC AIR AMBIENT TEMPERATURE.
b) HEATING - 40ºC / 45ºC ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 7ºC AIR AMBIENT TEMPERATURE.
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND
1m BELOW THE UNIT.
195 / 430
60
0.56 / 2.0
0.63 / 2.3
M4AC050C
50000
14654
5955
380-415 / 3 / 50
1410 / 55.5
1160 / 45.7
460 / 18.1
196 / 432
60
0.70 / 2.5
0.70 / 2.5
6.8
40 / 1.41
M4AC050CR
46000
13481
51000
14947
5446
5647
380-415 / 3 / 50
1410 / 55.5
1160 / 45.7
460 / 18.1
196 / 432
60
0.64 / 2.3
0.71 / 2.6
M4AC060C
52000
15240
6859
203 / 448
61
0.73 / 2.6
0.73 / 2.6
7.0
M4AC060CR
51000
14947
60000
17584
6507
6268
203 / 448
61
0.71 / 2.6
0.84 / 3.0
0.64 / 2.3
0.71 / 2.6
0.71 / 2.6
0.84 / 3.0
8.2
6.4
7.5
3.5
CAST IRON / STAINLESS STEEL
40 / 1.41
S2
Mini Chiller Specifications
MAC080C - MAC150C (Cooling Only, R22)
MODEL
NOMINAL COOLING CAPACITY
NOMINAL TOTAL INPUT POWER
POWER SOURCE
REFRIGERANT TYPE
CONTROL
UNIT DIMENSION
UNIT WEIGHT
SOUND PRESSURE LEVEL
EVAPORATOR
NOMINAL WATER FLOW
HYDRAULIC KIT
MAX. WATER OPER. PRESSURE
PUMP
WATER FLOW RATE
INSTALLATION PIPE CONNECITON
PIPING
HEAD
MATERIAL
TANK
CAPACITY/VOLUME
COMPRESSOR
STAGE OF CAPACITY CONTROL (Btu/h)
HEIGHT
WIDTH
DEPTH
Btu/h
W
W
V/Ph/Hz mm/in mm/in mm/in kg/lb dBA l/s/m 3 /hr kPa/psi l/s/m 3 /hr mm/in m
L/ft 3
MAC080C
78000
22860
8667
340 / 750
65
1500 / 59.1
900 / 35.4
MAC100C
93000
27257
10175
380-415 / 3 / 50
R22
TXV
1245 / 49.0
MAC120C
116000
33998
11005
350 / 772
66
MAC150C
138000
40445
13779
460 / 1014
67
1800 / 70.9
1150 / 45.3
540 / 1190
69
1.08 / 3.9
1.31 / 4.7
1.67 / 6.0
2.00 / 7.2
1.08 / 3.9
26.0
1.31 / 4.7
23.5
1000 / 145
42 / 1 1/4"
1.67 / 6.0
25.0
NA
NA
0 - 50 - 100%
2.00 / 7.2
23.0
MAC080CR - MAC150CR (Heatpump, R22)
MODEL
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER
COOLING
HEATING
POWER SOURCE
REFRIGERANT TYPE
CONTROL
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
SOUND PRESSURE LEVEL
EVAPORATOR
NOMINAL WATER FLOW
COOLING
HEATING
HYDRAULIC KIT
MAX. WATER OPER. PRESSURE
PUMP COOLING
WATER FLOW RATE
HEATING
INSTALLATION PIPE CONNECITON
PIPING
HEAD
COOLING
HEATING
TANK
MATERIAL
CAPACITY/VOLUME
COMPRESSOR
STAGE OF CAPACITY CONTROL (Btu/h)
Btu/h
W
Btu/h
W
W
W
V/Ph/Hz mm/in mm/in mm/in kg/lb dBA l/s/m l/s/m kPa/psi l/s/m 3 /hr l/s/m 3 /hr mm/in m m
L/ft 3
MAC080CR
77000
22567
90000
26376
9577
9329
350 / 772
65
1.08 / 3.9
1.14 / 4.1
1.08 / 3.9
1.14 / 4.1
26.0
25.0
1500 / 59.1
900 / 35.4
MAC100CR
94000
27549
110000
32239
11255
10759
360 / 794
66
1.31 / 4.7
1.37 / 4.9
1.31 / 4.7
1.37 / 4.9
23.5
22.5
1000 / 145
42 / 1 1/4"
NA
NA
0 - 50 - 100%
Notes:
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 12ºC / 7ºC ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 35ºC AIR AMBIENT TEMPERATURE.
b) HEATING - 40ºC / 45ºC ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 7ºC AIR AMBIENT TEMPERATURE.
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND
1m BELOW THE UNIT.
MAC120CR
380-415 / 3 / 50
R22
CAPILLARY TUBE
1245 / 49.0
113000
33118
120000
35169
11714
11948
480 / 1058
67
1.67 / 6.0
1.79 / 6.4
1.67 / 6.0
1.79 / 6.4
25.0
24.5
1800 / 70.9
1150 / 45.3
MAC150CR
138000
40445
132000
38686
13881
14572
560 / 1235
69
2.00 / 7.2
2.10 / 7.6
2.00 / 7.2
2.10 / 7.6
23.0
22.5
S3
Mini Chiller Specifications
M4AC080C - M4AC150C (Cooling Only, R407C)
MODEL
NOMINAL COOLING CAPACITY
NOMINAL TOTAL INPUT POWER
POWER SOURCE
REFRIGERANT TYPE
CONTROL
UNIT DIMENSION
UNIT WEIGHT
SOUND PRESSURE LEVEL
EVAPORATOR
NOMINAL WATER FLOW
HYDRAULIC KIT
MAX. WATER OPER. PRESSURE
PUMP
WATER FLOW RATE
INSTALLATION PIPE CONNECITON
PIPING
HEAD
MATERIAL
TANK
CAPACITY/VOLUME
COMPRESSOR
STAGE OF CAPACITY CONTROL (Btu/h)
HEIGHT
WIDTH
DEPTH
Btu/h
W
W
V/Ph/Hz mm/in mm/in mm/in kg/lb dBA l/s/m 3 /hr kPa/psi l/s/m 3 /hr mm/in m
L/ft 3
M4AC080C
74000
21688
9463
340 / 750
65
1500 / 59.1
900 / 35.4
M4AC100C
88000
25791
10771
380-415 / 3 / 50
R22
TXV
1245 / 49.0
M4AC120C
115000
33705
11805
350 / 772
66
460 / 1014
67
1800 / 70.9
1150 / 45.3
M4AC150C
13700
40152
14531
540 / 1190
69
1.08 / 3.9
1.31 / 4.7
1.67 / 6.0
2.00 / 7.2
1.08 / 3.9
26.0
1.31 / 4.7
23.5
1000 / 145
42 / 1 1/4"
1.67 / 6.0
25.0
NA
NA
0 - 50 - 100%
2.00 / 7.2
23.0
M4AC080CR - M4AC150CR (Heatpump, R407C)
MODEL
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER
COOLING
HEATING
POWER SOURCE
REFRIGERANT TYPE
CONTROL
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
SOUND PRESSURE LEVEL
EVAPORATOR
NOMINAL WATER FLOW
COOLING
HEATING
HYDRAULIC KIT
MAX. WATER OPER. PRESSURE
PUMP COOLING
WATER FLOW RATE
HEATING
INSTALLATION PIPE CONNECITON
PIPING
HEAD
COOLING
HEATING
TANK
MATERIAL
CAPACITY/VOLUME
COMPRESSOR
STAGE OF CAPACITY CONTROL (Btu/h)
Btu/h
W
Btu/h
W
W
W
V/Ph/Hz mm/in mm/in mm/in kg/lb dBA l/s/m l/s/m m m
3
3
L/ft 3
/hr
/hr kPa/psi l/s/m 3 /hr l/s/m 3 /hr mm/in
M4AC080CR
74000
21688
90000
26377
9946
9975
340 / 750
65
1.08 / 3.9
1.14 / 4.1
1.08 / 3.9
1.14 / 4.1
26.0
25.0
1500 / 59.1
900 / 35.4
M4AC100CR
88000
25791
98000
28722
11028
11134
350 / 772
66
1.31 / 4.7
1.37 / 4.9
1.31 / 4.7
1.37 / 4.9
23.5
22.5
380-415 / 3 / 50
R22
TXV
1245 / 49.0
M4AC120CR
110000
32239
118000
34583
12273
12386
1000 / 145
42 / 1 1/4"
NA
NA
0 - 50 - 100%
Notes:
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 12ºC / 7ºC ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 35ºC AIR AMBIENT TEMPERATURE.
b) HEATING - 40ºC / 45ºC ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 7ºC AIR AMBIENT TEMPERATURE.
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND
1m BELOW THE UNIT.
460 / 1014
67
1.67 / 6.0
1.79 / 6.4
1.67 / 6.0
1.79 / 6.4
25.0
24.5
1800 / 70.9
1150 / 45.3
M4AC150CR
130000
38101
144000
42204
15151
15824
540 / 1190
69
2.00 / 7.2
2.10 / 7.6
2.00 / 7.2
2.10 / 7.6
23.0
22.5
S4
Mini Chiller Specifications
M5AC020CR - M5AC055CR (Heatpump, R410A)
MODEL
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
Btu/h
W
Btu/h
W
W
W
V/Ph/Hz
NOMINAL TOTAL INPUT POWER
COOLING
HEATING
POWER SOURCE
REFRIGERANT TYPE
CONTROL
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
SOUND PRESSURE LEVEL
EVAPORATOR
NOMINAL WATER FLOW
COOLING
HEATING
HYDRAULIC KIT
MAX. WATER OPER. PRESSURE
PUMP
WATER FLOW RATE
COOLING
HEATING
PIPING
TANK
INSTALLATION PIPE CONNECITON
COOLING
HEAD
HEATING
MATERIAL
CAPACITY/VOLUME
COMPRESSOR
STAGE OF CAPACITY CONTROL (Btu/h) mm/in mm/in mm/in kg/lb dBA l/s/m 3 /hr l/s/m 3 /hr kPa/psi l/s/m 3 /hr l/s/m 3 /hr mm/in m m
L/ft 3
M5AC020CR M5AC025CR
17000
4980
21500
6300
2550
2590
220-240 / 1 / 50
21000
6150
25000
7330
2760
2790
CAPILLARY TUBE
125 / 276
57
800 / 31.5
1160 / 45.7
460 / 18.1
165 / 364
57
0.23 / 0.84
0.32 / 1.16
0.23 / 0.84
0.32 / 1.16
8.7
7.7
10.1
9.3
CAST IRON / STAINLESS STEEL
22 / 0.78
0 - 100%
0.28 / 1.00
0.35 / 1.25
0.28 / 1.00
0.35 / 1.25
M5AC030CR
26800
7848
32500
9517
3720
3630
790 / 31.1
1010 / 39.8
460 / 18.1
125 / 276
58
R410A
M5AC040CR M5AC050CR
37500
10981
40800
11947
47000
13763
51000
14934
4330
4490
5090
5130
220-240 / 1 / 50 or 380-415 / 3 / 50
CAPILLARY TUBE & TXV
1410 / 55.5
1010 / 39.8
460 / 18.1
165 / 364
60
167 / 368
60
M5AC055CR
50000
14641
55000
16105
5890
5990
1410 / 55.5
1010 / 39.8
460 / 18.1
173 / 381
60
0.42 / 1.5
0.42 / 1.5
0.53 / 1.9
0.53 / 1.9
0.64 / 2.3
0.64 / 2.3
0.72 / 2.6
0.72 / 2.6
0.42 / 1.5
1000 / 145
0.53 / 1.9
25.4 / 1
9.0
7.7
10.0
8.9
0 - 50 - 100%
0.64 / 2.3
NA
NA
0 - 40 - 60 - 100%
7.9
6.4
0.72 / 2.6
7.9
5.7
0 - 50 - 100%
M5ACV030CR - M5ACV135CR (Inverter Heatpump, R410A)
MODEL
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER
COOLING
HEATING
POWER SOURCE
REFRIGERANT TYPE
CONTROL
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
SOUND PRESSURE LEVEL
EVAPORATOR
NOMINAL WATER FLOW
COOLING
HEATING
HYDRAULIC KIT
MAX. WATER OPER. PRESSURE
WATER FLOW RATE
COOLING
HEATING
PIPING
TANK
INSTALLATION PIPE CONNECITON
COOLING
HEAD
HEATING
MATERIAL
CAPACITY/VOLUME
COMPRESSOR
STAGE OF CAPACITY CONTROL (Btu/h)
Btu/h
W
Btu/h
W
W
W
V/Ph/Hz mm/in mm/in mm/in kg/lb dBA l/s/m l/s/m kPa/psi l/s/m 3 /hr l/s/m 3 /hr mm/in m m
3
3
L/ft 3
/hr
/hr
M5ACV030CR
27000
7913
33000
9663
5279
4418
220-240 / 1 / 50
M5ACV055CR
50000
14654
55000
16119
7600
6100
M5ACV075CR
70000
20515
75000
21980
9050
7900
ELECTRONIC EXPANSION VALVE (EXV)
790 / 31.1
1410 / 55.5
1010 / 39.8
1460 / 57.5
1150 / 45.3
1010 / 39.8
460 / 18.1
128 / 282
59
0.3 ( 1.3 )
0.4 ( 1.5 )
0.3 ( 1.3 )
0.4 ( 1.5 )
7.7
7.0
460 / 18.1
195 / 430
62
0.7 ( 2.5 )
0.8 ( 2.7 )
0.7 ( 2.5 )
0.8 ( 2.7 )
12.7
11.5
550 / 21.7
200 / 440
65
0.9 ( 3.4 )
1.0 ( 3.7 )
0.9 ( 3.4 )
1.0 ( 3.7 )
25.4 / 1
22.3
21.3
M5ACV100CR
1000 / 145
NA
NA
1.3 ( 4.8 )
1.4 ( 5.0 )
1.3 ( 4.8 )
1.4 ( 5.0 )
17.3
15.7
0 - 28700 0 - 55000 0 - 75000 73000 - 122000
Notes:
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 12ºC / 7ºC ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 35ºC AIR AMBIENT TEMPERATURE.
b) HEATING - 40ºC / 45ºC ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 7ºC AIR AMBIENT TEMPERATURE.
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND
1m BELOW THE UNIT.
M5ACV135CR
95000
27800
100000
29300
12000
11400
131500
38540
141500
41470
15750
16250
R410A
380-415 / 3 / 50
EXV / CAPILLARY TUBE
1260 / 49.6
1260 / 49.6
1800 / 70.9
1500 / 59.1
900 / 35.4
360 / 794
1150 / 45.3
560 / 1235
63 67
1.8 ( 6.6 )
2.0 ( 7.1 )
1.8 ( 6.6 )
2.0 ( 7.1 )
16.5
14.5
99000 - 149000
M5ACV210CR
200000
58617
210000
61548
22300
21800
EXV / CAPILLARY TUBE
1786 / 70.31
2093 / 82.4
1192 / 46.9
682
85
2.67 (9.8)
2.86 (10.5)
2.7 (9.6)
2.9 (10.3)
38.0 / 1.5
25
25
73000 - 220000
S5
Chilled Water Fan Coil Unit Specifications
MCK020AW - MCK050AW (Ceilling Cassette A Series)
MODEL
NOMINAL TOTAL COOLING CAPACITY
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL TOTAL HEATING CAPACITY (ENTERING
WATER TEMP. = 70ºC)
NOMINAL AIR FLOW
UNIT DIMENSION - ( ) WITH PANEL
HIGH
MEDIUM
LOW
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT ( UNIT + PANEL )
SOUND PRESSURE LEVEL ( H/M/L )
NOMINAL WATER FLOW RATE
HEAD LOSS (COOLING)
HEAD LOSS (HEATING) : 70ºC
CONNECTION
Btu/h
W
Btu/h
W
Btu/h
W l/s/CFM l/s/CFM l/s/CFM mm/in mm/in mm/in kg/lb dBA
USGPM
LITRES/M kPa/psi kPa/psi
MCK020AW
24000
7027
17800
5212
48000
14054
349 / 740
297 / 630
283 / 600
( 31+4 ) / ( 1.2+0.2 )
42 / 39 / 37
5.20
19.68
19.44 / 2.82
15.17 / 2.20
MCK025AW MCK030AW MCK040AW
25600
7496
18800
5505
50000
14640
368 / 780
312 / 660
283 / 600
29500
8638
21600
6324
58000
16982
415 / 880
349 / 740
321 / 680
335 / 13.2 ( 363 / 14.3 )
35000
10248
25500
7466
64500
18886
467 / 990
406 / 860
359 / 760
820 / 32.3 ( 930 / 36.6 )
821 / 32.3 ( 930 / 36.6 )
( 35+4 ) / ( 1.4+0.2 ) ( 38+4 ) / ( 1.5+0.2 ) ( 32+4 ) / ( 1.3+0.2 )
45 / 42 / 40
5.80
21.96
23.58 / 3.42
18.48 / 2.68
49 / 45 / 43
6.70
25.36
30.47 / 4.42
24.27 / 3.52
3/4" BSP FEMALE UNION
51 / 48 / 46
7.30
27.63
35.44 / 5.14
28.41 / 4.12
MCK050AW
40000
11712
29600
8667
67000
19618
491 / 1040
448 / 950
411 / 870
( 40+4 ) / ( 1.6+0.2 )
53 / 52 / 50
7.50
28.39
37.16 / 5.39
29.85 / 4.33
MCK020AWH - MCK050AWH (4 Pipies Ceilling Cassette)
MODEL MCK020AWH MCK025AWH MCK030AWH MCK040AWH
NOMINAL TOTAL COOLING CAPACITY
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL TOTAL HEATING CAPACITY (ENTERING
WATER TEMP. = 70ºC)
NOMINAL AIR FLOW
UNIT DIMENSION - ( ) WITH PANEL
UNIT WEIGHT ( UNIT + PANEL )
SOUND PRESSURE LEVEL ( H/M/L )
NOMINAL WATER FLOW RATE
HIGH
MEDIUM
LOW
HEIGHT
WIDTH
DEPTH
Btu/h
W
Btu/h
W
Btu/h
W l/s/CFM l/s/CFM l/s/CFM mm/in mm/in mm/in kg/lb dBA
USGPM
LITRES/M kPa/psi kPa/psi
13000
3806
11600
3396
33300
9750
349 / 740
297 / 630
283 / 600
( 31+4 ) / ( 1.2+0.2 )
42 / 39 / 37
2.90
10.98
3.56 / 0.52
4.76 / 0.69
13500
3953
12000
3514
34300
10043
368 / 780
312 / 660
283 / 600
15800
4626
13900
4070
39300
11507
415 / 880
349 / 740
321 / 680
335 / 13.2 ( 363 / 14.3 )
HEAD LOSS (COOLING)
HEAD LOSS (HEATING) : 70ºC
CONNECTION
Notes:
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - ENTERING AIR TEMP. : 27ºC (80.6ºF) DB / 19ºC (66.2ºF) WB, ENTERING WATER TEMP. : 7ºC (44.6ºF), LEAVING WATER TEMP. : 12ºC (53.6ºF) b) HEATING - ENTERING AIR TEMP.: 20ºC (68ºF) DB, ENTERING WATER TEMP. : 70ºC (158ºF), LEAVING WATER TEMP. : 65ºC (149ºF)
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS C 9612 STANDARD. MCK020/025AW/AWH : POSITION OF THE MEASUREMENT POINT IS 1.4m
BELOW THE FACIA. MCK030/040/050AW/AWH : 1.5m BELOW THE FACIA (JIS B 8615).
17100
5007
15000
4392
42150
12342
467 / 990
406 / 860
359 / 760
820 / 32.3 ( 930 / 36.6 )
821 / 32.3 ( 930 / 36.6 )
( 35+4 ) / ( 1.4+0.2 ) ( 38+4 ) / ( 1.5+0.2 ) ( 32+4 ) / ( 1.3+0.2 )
45 / 42 / 40
3.00
11.36
3.78 / 0.55
5.45 / 0.79
49 / 45 / 43
3.50
13.25
4.94 / 0.72
7.17 / 1.04
3/4" BSP FEMALE UNION
51 / 48 / 46
3.80
14.39
35.44 / 5.14
28.41 / 4.12
MCK050AWH
17600
5153
15500
4538
43500
12737
491 / 1040
448 / 950
411 / 870
( 40+4 ) / ( 1.6+0.2 )
53 / 52 / 50
3.90
14.76
37.16 / 5.39
29.85 / 4.33
S6
Chilled Water Fan Coil Unit Specifications
MCK015BW - MCK025BW (Ceilling Cassette B Series)
MODEL
NOMINAL TOTAL COOLING CAPACITY
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL TOTAL HEATING CAPACITY (ENTERING
WATER TEMP. = 70…C)
NOMINAL AIR FLOW
UNIT DIMENSION - ( ) WITH PANEL
UNIT WEIGHT ( UNIT + PANEL )
SOUND PRESSURE LEVEL ( H/M/L )
NOMINAL WATER FLOW RATE
HEAD LOSS (COOLING)
HEAD LOSS (HEATING) : 70…C
CONNECTION
HIGH
MEDIUM
LOW
HEIGHT
WIDTH
DEPTH
Btu/h
W
Btu/h
W
Btu/h
W l/s/CFM l/s/CFM l/s/CFM mm/in mm/in mm/in kg/lb dBA
USGPM
LITRES/M kPa/psi kPa/psi
MCK015BW MCK020BW
12500
3664
9250
2711
27000
7913
17000
4982
11320
3318
30000
8792
194 / 410
167 / 350
140 / 300
293 / 11.5 ( 345 / 13.6 )
650 / 25.6 ( 727 / 28.6 )
650 / 25.6 ( 727 / 28.6 )
( 30+3 ) / ( 1.2+0.1 )
36 / 33 / 29
2.92
0.18
38.96 / 5.65
31.23 / 4.53
40 / 36 / 30
3.78
0.24
9.56 / 1.39
7.31 / 1.06
3/4" BSP FEMALE UNION
MCK025BW
20000
5862
13300
3898
35700
10463
226 / 480
200 / 420
176 / 370
( 31+3 ) / ( 1.2+0.1 )
43 / 41 / 37
3.90
0.25
10.09 / 1.46
14.67 / 2.13
MCK010CW - MCK020CW (Ceilling Cassette C Series)
MODEL MCK010CW MCK015CW MCK020CW
NOMINAL TOTAL COOLING CAPACITY
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL TOTAL HEATING CAPACITY (ENTERING
WATER TEMP. = 70…C)
NOMINAL AIR FLOW
UNIT DIMENSION - ( ) WITH PANEL
UNIT WEIGHT ( UNIT + PANEL )
SOUND PRESSURE LEVEL ( H/M/L )
NOMINAL WATER FLOW RATE
HIGH
MEDIUM
LOW
HEIGHT
WIDTH
DEPTH
Btu/h
W
Btu/h
W
Btu/h
W l/s/CFM l/s/CFM l/s/CFM mm/in mm/in mm/in kg/lb dBA
USGPM
LITRES/M
9000
2635
7000
2050
15000
4396
15000
4392
11000
3221
24000
7034
16900
4948
12000
3514
( 22+2 ) / ( 0.9+0.1 )
175 / 370
165 / 350
250 / 9.8 ( 295 / 11.6 )
570 / 22.4 ( 640 / 25.2 )
570 / 22.4 ( 640 / 25.2 )
( 23+2 ) / ( 0.9+0.1 )
193 / 410
184 / 390
44 / 43 / 42
1.90
7.19
184 / 390
44 / 42 / 41
3.30
12.49
25800
7562
203 / 430
47 / 46 / 44
3.60
13.63
35.83 / 5.20
131.33 / 19.05
HEAD LOSS (COOLING)
HEAD LOSS (HEATING) : 70…C
CONNECTION kPa/psi kPa/psi
57.42 / 8.33
213.42 / 30.95
30.83 / 4.47
114.94 / 16.67
3/4" BSP FEMALE UNION
Notes:
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - ENTERING AIR TEMP. : 27…C (80.6…F) DB / 19…C (66.2…F) WB, ENTERING WATER TEMP. : 7…C (44.6…F), LEAVING WATER TEMP. : 12…C (53.6…F) b) HEATING - ENTERING AIR TEMP. : 20…C (68…F) DB, ENTERING WATER TEMP. : 70…C (158…F), LEAVING WATER TEMP. : 65…C (149…F)
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW THE FACIA.
S7
Chilled Water Fan Coil Unit Specifications
MCM007CBW - MCM020DW (Ceilling Convertibele)
MODEL
NOMINAL TOTAL COOLING CAPACITY
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL TOTAL HEATING CAPACITY (ENTERING
WATER TEMP. = 70…C)
NOMINAL AIR FLOW
UNIT DIMENSION
HIGH
MEDIUM
LOW
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
SOUND PRESSURE LEVEL ( H/M/L )
NOMINAL WATER FLOW RATE
HEAD LOSS (COOLING)
HEAD LOSS (HEATING) : 70…C
CONNECTION
Btu/h
W
Btu/h
W
Btu/h
W l/s/CFM l/s/CFM l/s/CFM mm/in mm/in mm/in kg/lb dBA
USGPM
LITRES/M kPa/psi kPa/psi
MCM007CBW
6500
1903
4986
1460
13500
3953
94 / 200
82 / 170
73 / 150
45 / 42 / 37
1.35
5.30
9.31 / 1.35
6.58 / 0.96
MCM010CBW MCM015CBW
824 / 32.4
33 / 72.8
8500
2489
6656
1949
10500
3074
8568
2509
18000
5270
148 / 310
134 / 280
119 / 250
235 / 9.3
666 / 26.2
24500
7174
189 / 400
156 / 330
140 / 300
46 / 43 / 38
1.80
6.81
1174 / 46.2
35 / 77.2
47 / 44 / 39
2.30
10.46
15.37 / 2.23
11.86 / 1.72
4.48 / 0.65
3.38 / 0.49
3/4" BSP FEMALE ADAPTOR
MCM025DW - MCM050DW (Ceilling Convertibele)
MODEL MCM025DW MCM030DW MCM040DW MCM050DW
NOMINAL TOTAL COOLING CAPACITY
NOMINAL SENSIBLE COOLING CAPACITY
Btu/h
W
Btu/h
W
22000
6442
16786
4915
25000
7320
18875
5527
40000
11712
29200
8550
45000
13176
32535
9526
NOMINAL TOTAL HEATING CAPACITY (ENTERING
WATER TEMP. = 60…C)
NOMINAL AIR FLOW
UNIT DIMENSION
UNIT WEIGHT
SOUND PRESSURE LEVEL ( H/M/L )
NOMINAL WATER FLOW RATE
HIGH
MEDIUM
LOW
HEIGHT
WIDTH
DEPTH
Btu/h
W l/s/CFM l/s/CFM l/s/CFM mm/in mm/in mm/in kg/lb dBA
USGPM
LITRES/M
40000
11712
297 / 630
293 / 620
262 / 550
214 / 8.4
43 / 94.8
54 / 53 / 50
4.20
18.42
1214 / 47.8
46000
13469
329 / 700
325 / 690
306 / 650
45 / 99.2
51 / 50 / 48
4.90
21.77
670 / 26.4
75000
21960
450 / 950
428 / 910
420 / 890
249 / 9.8
54 / 53 / 52
8.60
31.82
HEAD LOSS (COOLING)
HEAD LOSS (HEATING) : 60…C
CONNECTION kPa/psi kPa/psi
19.10 / 2.77
14.89 / 2.16
16.96 / 2.46
13.10 / 1.90
11.86 / 1.72
9.10 / 1.32
3/4" BSP FEMALE ADAPTOR
Notes:
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - ENTERING AIR TEMP. : 27…C (80.6…F) DB / 19…C (66.2…F) WB, ENTERING WATER TEMP. : 7…C (44.6…F), LEAVING WATER TEMP. : 12…C (53.6…F) b) HEATING - ENTERING AIR TEMP.: 20…C (68…F) DB, ENTERING WATER TEMP. : 70`C (158`F), LEAVING WATER TEMP. : 65`C (149`F)
C) MCM025DW-MCM050DW: HEATING - ENTERING AIR TEMP.: 20…C (68…F) DB, ENTERING WATER TEMP. : 60…C (140…F), LEAVING WATER TEMP. : 55…C (131…F)
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS C 9612 STANDARD. MCM020/025DW : POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT
AND 0.8m BELOW THE UNIT. MCM030/040/050DW : 1 m IN FRONT OF THE UNIT AND 1m BELOW THE AIR DISCHARGE OPENING. (JIS B 8615)
MCE007-015CBW: 1m IN FRONT AND 0.8m BELOW THE VERTICAL CENTRE LINE OF THE UNIT.
1714 / 67.5
70 / 154.3
85000
24888
500 / 1060
483 / 1020
450 / 950
54 / 53 / 52
9.30
40.19
13.58 / 1.97
10.48 / 1.52
MCM020DW
20000
5856
15140
4433
35000
10248
264 / 560
239 / 510
193 / 410
214 / 8.4
1214 / 47.8
670 / 26.4
43 / 94.8
50 / 47 / 40
3.90
16.75
16.75 / 2.43
13.03 / 1.89
S8
Chilled Water Fan Coil Unit Specifications
MCC010CW - MCC028CW (Ceiling Concealed)
MODEL
NOMINAL TOTAL COOLING CAPACITY
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL TOTAL HEATING CAPACITY (ENTERING
WATER TEMP. = 60ºC)
NOMINAL AIR FLOW
SUPER HIGH
HIGH
MEDIUM
LOW
EXTERNAL STATIC ( H/M/L )
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
SOUND PRESSURE LEVEL ( H/M/L )
NOMINAL WATER FLOW RATE
HEAD LOSS (COOLING)
HEAD LOSS (HEATING) : 60ºC
CONNECTION l/s/CFM l/s/CFM l/s/CFM l/s/CFM mmAq mm/in mm/in
Btu/h
W
Btu/h
W
Btu/h
W mm/in kg/lb dBA
USGPM
LITRES/M kPa/psi kPa/psi
MCC010CW
NA
142 / 300
123 / 260
104 / 220
5 / 4 / 3
261 / 10.3
765 / 30.1
9900
2902
7000
2052
19000
5569
411 / 16.2
17 / 37.5
33 / 30 / 26
2.00
7.57
8.83 / 1.28
6.69 / 0.97
MCC015CW
15000
4396
10000
2931
25500
7474
NA
241 / 510
208 / 440
170 / 360
5 / 4 / 3
262 / 10.3
905 / 35.6
412 / 16.2
21 / 46.3
37 / 34 / 29
2.58
9.77
13.97 / 2.03
10.76 / 1.56
MCC020CW
18000
5275
13600
3986
38000
11137
NA
330 / 700
321 / 680
293 / 620
5 / 4 / 3
263 / 10.3
1065 / 41.9
413 / 16.2
22 / 48.5
38 / 36 / 34
4.20
15.90
18.28 / 2.65
14.20 / 2.06
3/4" BSP FEMALE ADAPTOR
MCC025CW
22500
6594
17900
5246
48000
14068
NA
345 / 730
340 / 720
274 / 580
5 / 4 / 3
261 / 10.3
1200 / 47.2
411 / 16.2
25 / 55.1
40 / 39 / 36
4.70
17.79
24.12 / 3.50
18.96 / 2.75
MCC030CW - MCC060CW (Ceiling Concealed)
MODEL MCC030CW MCC038CW MCC040CW MCC050CW MCC060CW
NOMINAL TOTAL COOLING CAPACITY
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL TOTAL HEATING CAPACITY (ENTERING
WATER TEMP. = 60ºC)
NOMINAL AIR FLOW
NOMINAL WATER FLOW RATE
HEAD LOSS (COOLING)
HEAD LOSS (HEATING) : 60ºC
CONNECTION
SUPER HIGH
HIGH
MEDIUM
LOW
EXTERNAL STATIC ( SH/H/M/L )
HEIGHT
UNIT DIMENSION
UNIT WEIGHT
SOUND PRESSURE LEVEL ( SH/H/M/L )
WIDTH
DEPTH
Btu/h
W
Btu/h
W
Btu/h
W l/s/CFM l/s/CFM l/s/CFM l/s/CFM mmAq mm/in mm/in mm/in kg/lb dBA
USGPM
LITRES/M kPa/psi kPa/psi
28000
8206
21800
6389
60000
17585
425 / 900
392 / 830
359 / 760
335 / 710
21 / 17 / 13 / 9
378 / 14.9
929 / 36.6
541 / 21.3
39 / 86.0
49 / 46 / 42 / 38
6.20
23.47
12.82 / 1.89
9.86 / 1.43
35000
10258
27600
8089
65000
19050
727 / 1540
694 / 1470
670 / 1420
637 / 1350
14 / 12 / 11 / 9
310 / 12.2
1247 / 49.1
638 / 25.1
41 / 90.4
55 / 51 / 48 / 45
9.60
36.34
44.24 / 6.42
35.78 / 5.19
3/4" BSP FEMALE ADAPTOR
38000
11137
34000
9965
75000
21981
519 / 1100
500 / 1060
467 / 990
425 / 900
21/ 18 / 13 / 9
378 / 14.9
1045 / 41.1
541 / 21.3
42 / 92.6
51 / 49 / 45 / 41
7.40
28.01
18.86 / 2.74
14.69 / 2.13
Notes:
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - ENTERING AIR TEMP. : 27¡C (80.6¡F) DB / 19¡C (66.2¡F) WB, ENTERING WATER TEMP. : 7¡C (44.6¡F), LEAVING WATER TEMP. : 12¡C (53.6¡F) b) HEATING - ENTERING AIR TEMP.: 20¡C (68¡F) DB, ENTERING WATER TEMP. : 60¡C (140¡F), LEAVING WATER TEMP. : 55¡C (131¡F)
4) SOUND PRESSURE LEVEL ARE ACCORDING TO GB STD - GB/D17758. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW THE CENTRE
OF THE UNIT. TESTED WITH 2m LENGTH DUCT AT THE AIR DISCHARGE OUTLET ANS AIR RETURN INLET.
47000
13775
34700
10170
95000
27843
750 / 1590
651 / 1380
54000
15826
39900
11694
110000
32239
779 / 1650
722 / 1530
604 / 1280
571 / 1210
18 / 16 / 14 / 11
378 / 14.9
1299 / 51.1
541 / 21.3
54 / 119.0
675 / 1430
609 / 1290
18 / 16 / 14 / 10
379 / 14.9
1499 / 59.0
542 / 21.3
62 / 136.7
53 / 52 / 50 / 47
10.00
37.85
37.08 / 5.38
55 / 53 / 50 / 47
10.80
40.88
7.01 / 1.02
29.65 / 4.30
5.38 / 0.78
7/8" BSP FEMALE ADAPTOR
MCC028CW
26000
7620
19500
5715
55000
16120
401 / 850
382 / 810
363 / 770
335 / 710
10 / 8 / 7 / 6
290 / 11.4
942 / 37.1
600 / 23.6
38 / 83.8
44 / 41 / 38 / 34
5.70
21.58
14.69 / 2.13
11.38 / 1.65
S9
Chilled Water Fan Coil Unit Specifications
MCW200C - MCW1200C (Ceilling Concealed)
MODEL MCW200C
NOMINAL TOTAL COOLING CAPACITY
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL TOTAL HEATING CAPACITY
(ENTERING WATER TEMP. = 60ºC)
Btu/h
W
Btu/h
W
Btu/h
W
7710
2260
5120
1501
13440
3939
NOMINAL AIR FLOW
SUPER HIGH l/s/CFM
HIGH l/s/CFM
MEDIUM
LOW l/s/CFM l/s/CFM
NA
114 / 241
94 / 200
64 / 135
EXTERNAL STATIC ( H/M/L )
UNIT DIMENSION
UNIT WEIGHT
HEIGHT
WIDTH
DEPTH mmAq mm/in mm/in mm/in kg/lb
251 / 9.9
714 / 28.1
490 / 19.3
19
SOUND PRESSURE LEVEL ( H/M/L ) AT 60Pa dBA
USGPM
40.1 / 37.2 / 34.9
1.85
NOMINAL WATER FLOW RATE
HEAD LOSS (COOLING)
LITRES/M kPa/psi
7.00
14.6 / 2.12
HEAD LOSS (HEATING) : 60ºC
CONNECTION kPa/psi 14.6 / 2.12
MCW300C MCW400C MCW600C MCW800C MCW1000C
11460
3359
7850
2301
19510
5718
NA
153 / 324
129 / 274
97 / 206
251 / 9.9
884 / 34.8
490 / 19.3
22
48.3 / 44.7 / 37.8
2.64
10.00
12 / 1.74
12 / 1.74
14450
4235
9740
2855
25740
7544
22260
6524
15020
4402
38640
11325
27880
8171
18470
5413
48510
14217
NA
214 / 453
144 / 306
109 / 230
NA
295 / 624
236 / 500
197 / 418
NA
403 / 853
328 / 695
256 / 542
251 / 9.9
1014 / 39.9
490 / 19.3
26
48.7 / 46.3 / 46.4
3.43
13.00
21.6 / 3.13
Up to 8.13 mmAq
251 / 9.9
1214 / 47.8
490 / 19.3
30
49.0 / 47.2 / 43.3
4.76
18.00
38.2 / 5.54
251 / 9.9
1464 / 57.6
490 / 19.3
41
53.1 / 51.5 / 49.7
6.34
24.00
18.4 / 2.67
21.6 / 3.13
38.2 / 5.54
3/4" BSP FEMALE ADAPTOR
18.4 / 2.67
251 / 9.9
1564 / 61.6
490 / 19.3
44
53.1 / 52.0 / 51.1
7.66
29.00
21 / 3.05
21 / 3.05
31360
9191
21290
6240
53970
15818
NA
455 / 965
378 / 800
305 / 647
251 / 9.9
1824 / 71.8
490 / 19.3
46
52.4 / 50.6 / 47.4
10.04
38.00
32.7 / 4.74
32.7 / 4.74
MCW1200C
40650
11914
27340
8013
69810
20460
NA
575 / 1218
489 / 1036
419 / 888
MCW200H - MCW1200H (Ceilling Concealed)
MODEL MCW200H
NOMINAL TOTAL COOLING CAPACITY
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL TOTAL HEATING CAPACITY
(ENTERING WATER TEMP. = 60ºC) - 3 ROWS
NOMINAL TOTAL HEATING CAPACITY
(ENTERING WATER TEMP. = 60ºC) - 1 ROW
NOMINAL AIR FLOW
SUPER HIGH
HIGH
MEDIUM
LOW
Btu/h
W
Btu/h
W
Btu/h
W
Btu/h
W l/s/CFM l/s/CFM l/s/CFM l/s/CFM
7710
2260
5220
1530
12180
3570
4810
1410
NA
113 / 240
94 / 200
76 / 160
EXTERNAL STATIC ( SH/H/M/L )
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
SOUND PRESSURE LEVEL ( H/M/L ) AT 60Pa
NOMINAL WATER FLOW RATE - 3 ROWS
NOMINAL WATER FLOW RATE - 1 ROW mmAq mm/in mm/in mm/in kg/lb dBA
USGPM
LITRES/M
USGPM
LITRES/M
251 / 9.9
714 / 28.1
490 / 19.3
20
40.1 / 37.2 / 34.9
1.80
6.80
0.87
3.30
HEAD LOSS (COOLING) - 3 ROWS
HEAD LOSS (HEATING) : 60ºC - 3 ROWs
HEAD LOSS (COOLING) - 1 ROW
HEAD LOSS (HEATING) : 60ºC - 1 ROW
CONNECTION kPa/psi kPa/psi kPa/psi kPa/psi
16 / 2.32
16 / 2.32
8 / 1.16
8 / 1.16
MCW300H
10240
3000
6960
2040
17200
5040
7850
2300
NA
165 / 350
142 / 300
94 / 200
251 / 9.9
884 / 34.8
490 / 19.3
24
48.3 / 44.7 / 37.8
2.51
9.50
1.22
4.60
13 / 1.89
13 / 1.89
8 / 1.16
8 / 1.16
MCW400H MCW600H MCW800H
14330
4200
9900
2900
24670
7230
11430
3350
NA
212 / 450
189 / 400
165 / 350
20810
6100
14330
4200
33300
9760
15120
4430
NA
316 / 670
307 / 650
212 / 450
251 / 9.9
1014 / 39.9
490 / 19.3
28
48.7 / 46.3 / 46.4
3.43
13.00
1.74
6.60
Up to 8.13 mmAq
251 / 9.9
1214 / 47.8
490 / 19.3
32
49.0 / 47.2 / 43.3
4.76
18.00
2.11
8.00
251 / 9.9
1464 / 57.6
490 / 19.3
44
53.1 / 51.5 / 49.7
6.13
23.20
2.38
9.00
22 / 3.19
22 / 3.19
47 / 6.82
47 / 6.82
33 / 4.79
33 / 4.79
15 / 2.18
17 / 2.47
21 / 3.05
15 / 2.18
17 / 2.47
3/4" BSP FEMALE ADAPTOR
21 / 3.05
26100
7650
18080
5300
43670
12800
17740
5200
NA
396 / 840
345 / 730
288 / 610
Notes:
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - ENTERING AIR TEMP. : 27ºC (80.6ºF) DB / 19.5ºC (67.1ºF) WB, ENTERING WATER TEMP. : 7¡C (44.6ºF), LEAVING WATER TEMP. : 12ºC (53.6ºF) b) HEATING - ENTERING AIR TEMP.: 21ºC (69.8ºF) DB, ENTERING WATER TEMP. : 60ºC (140ºF), LEAVING WATER TEMP. : 55ºC (131ºF)
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW THE FACIA.
251 / 9.9
1564 / 61.6
490 / 19.3
47
53.1 / 52.0 / 51.1
6.87
26.00
3.20
12.10
26 / 3.77
26 / 3.77
18 / 2.61
18 / 2.61
MCW1000H
28320
8300
20130
5900
49300
14450
23920
7010
NA
472 / 1000
415 / 880
302 / 640
251 / 9.9
1824 / 71.8
490 / 19.3
49
52.4 / 50.6 / 47.4
8.45
32.00
3.72
14.10
45 / 6.53
45 / 6.53
20 / 2.9
20 / 2.9
MCW1200H
34800
10200
26410
7740
64110
18790
29240
8570
NA
604 / 1280
519 / 1100
425 / 900
S10
Chilled Water Fan Coil Unit Specifications
MWM007GW - MWM025GW (Wall Mount)
MODEL
NOMINAL TOTAL COOLING CAPACITY
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL TOTAL HEATING CAPACITY (ENTERING
WATER TEMP. = 70ºC)
NOMINAL AIR FLOW
UNIT DIMENSION
UNIT WEIGHT
SOUND PRESSURE LEVEL ( H/M/L )
NOMINAL WATER FLOW RATE
HEAD LOSS (COOLING)
HEAD LOSS (HEATING) : 70ºC
CONNECTION
HIGH
MEDIUM
LOW
HEIGHT
WIDTH
DEPTH
Btu/h
W
Btu/h
W
Btu/h
W l/s/CFM l/s/CFM l/s/CFM mm/in mm/in mm/in kg/lb dBA
USGPM
LITRES/M kPa/psi kPa/psi
MWM007GW MWM010GW MWM015GW
8000
2340
5920
1732
18000
5275
130 / 275
106 / 225
83 / 175
260 / 10.2
799 / 31.5
9500
2780
6935
2029
21600
6331
142 / 300
118 / 250
94 / 200
260 / 10.2
899 / 35.4
198 / 7.8
10 / 22.1
40 / 35 / 29
1.85
7.00
41 / 5.9
39 / 34 / 28
2.11
8.00
54 / 7.8
198 / 7.8
12 / 26.5
42 / 36 / 29
2.38
9.00
67 / 9.7
37 / 5.4
44 / 6.4
1/2" BSP FEMALE ADAPTOR
59 / 8.6
11000
3220
8030
2351
24200
7093
163 / 345
135 / 285
104 / 220
MDB075BW - MDB0150BW (Ducted Blower)
MODEL MDB075BW MDB0100BW MDB0125BW
NOMINAL TOTAL COOLING CAPACITY
Btu/h
W
Btu/h
73000
21395
57200
95000
27843
71400
122500
35903
94500
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL TOTAL HEATING CAPACITY (ENTERING
WATER TEMP. = 70ºC)
W
Btu/h
W l/s/CFM
16764
160000
46893
1128 / 2390
20926
200000
58617
1444 / 3060
27696
265000
77667
1897 / 4020 NOMINAL AIR FLOW
EXTERNAL STATIC
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH mmAq mm/in mm/in mm/in kg/lb dBA
USGPM
572 / 22.5
1502 / 59.1
761 / 30.0
96 / 211.6
56
16.30
61.70
20.13 / 2.92
10
572 / 22.5
1502 / 59.1
761 / 30.0
100 / 220.5
885 / 34.8
1640 / 64.6
1040 / 40.9
140 / 308.6
UNIT WEIGHT
SOUND PRESSURE LEVEL
NOMINAL WATER FLOW RATE
HEAD LOSS (COOLING)
LITRES/M kPa/psi
57
20.00
75.71
16.27 / 2.36
58
27.10
102.58
22.75 / 3.30
HEAD LOSS (HEATING) : 70ºC
CONNECTION kPa/psi 15.89 / 2.30
12.69 / 1.84
17.93 / 2.60
1 1/8" BRAZING
Notes:
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - ENTERING AIR TEMP. : 27ºC (80.6ºF) DB / 19ºC (66.2ºF) WB, ENTERING WATER TEMP. : 7ºC (44.6ºF), LEAVING WATER TEMP. : 12ºC (53.6ºF) b) HEATING - ENTERING AIR TEMP.: 20ºC (68ºF) DB, ENTERING WATER TEMP. : 70ºC (158ºF), LEAVING WATER TEMP. : 65ºC (149ºF)
4) a) MDB: SOUND PRESSURE LEVEL ARE TESTED AT 1.4m BELOW THE UNIT (FREE RETURN AND THE DISCHARGE AIR WAS DUCTED TO ADJACENT ROOM).
b) MWM:SOUND PRESSURE LEVEL ARE ACCORDING TO JIS C 9612 STANDARD. MWMFW : POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND
0.8m BELOW THE UNIT. MWM301W : 1m IN FRONT AND 1 m BELOW THE DISCHARGE OPENING OF THE UNIT (JIS B 8615)
MWM020GW MWM025GW
16500
4840
13120
3848
35000
18000
5270
14760
4326
40500
10258
297 / 630
231 / 490
11870
312 / 660
274 / 580
208 / 440
304 / 12.0
1062 / 41.8
222 / 470
16 / 35.3
49 / 43 / 40
222 / 8.7
16 / 35.3
50 / 48 / 44
3.52
13.33
37 / 5.4
3.65
13.83
41 / 5.9
31 / 4.5
33 / 4.8
1/2" BSP FEMALE ADAPTOR
MWM301W
22000
6448
16720
4900
45080
13212
330 / 700
293 / 620
234 / 500
360 / 14.2
1200 / 47.2
200 / 7.8
20 / 44.2
49 / 47 / 45
4.60
17.40
52.20 / 7.60
68.78 / 9.98
5/8" BSP FEMALE
ADAPTOR
15
MDB0150BW
157800
46249
118000
34584
329000
96424
2077 / 4400
885 / 34.8
1640 / 64.6
1040 / 40.9
145 / 319.7
59
35.00
132.50
18.96 / 2.75
14.89 / 2.16
S11
Chilled Water Fan Coil Unit Specifications
MCE015EW - MCE025EW (Ceiling Convertible)
MODEL MCE015EW MCE020EW
NOMINAL TOTAL COOLING CAPACITY
NOMINAL SENSIBLE COOLING CAPACITY
NOMINAL TOTAL HEATING CAPACITY (ENTERING
WATER TEMP. = 70ºC)
NOMINAL AIR FLOW
UNIT DIMENSION
UNIT WEIGHT
SOUND PRESSURE LEVEL ( H/M/L )
NOMINAL WATER FLOW RATE
HEAD LOSS (COOLING)
HEAD LOSS (HEATING) : 50ºC
CONNECTION
HIGH
MEDIUM
LOW
HEIGHT
WIDTH
DEPTH
Btu/h
W
Btu/h
W
Btu/h
W l/s/CFM l/s/CFM l/s/CFM mm/in mm/in mm/in kg/lb dBA
USGPM
LITRES/M kPa/psi kPa/psi
15000
4396
12800
3751
33000
9672
245 / 520
217 / 460
192 / 406
27 / 59.7
48 / 46 / 43
3.21
12.20
28 / 4.0
23 / 3.3
19500
5715
15500
4543
38000
11137
274 / 580
250 / 530
231 / 490
212.5 / 8.4
1090 / 42.9
630 / 24.8
27 / 59.7
50 / 47 / 46
4.53
17.10
47 / 6.8
42 / 6.0
1/2" BSP FEMALE ADAPTOR
Notes:
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - ENTERING AIR TEMP. : 27ºC (80.6ºF) DB / 19ºC (66.2ºF) WB, ENTERING WATER TEMP. : 7ºC (44.6ºF), LEAVING WATER TEMP. : 12ºC (53.6ºF) b) HEATING - ENTERING AIR TEMP.: 20ºC (68ºF) DB, ENTERING WATER TEMP. : 70ºC (158ºF), LEAVING WATER TEMP. : 65ºC (149ºF)
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT
MCE025EW
20500
6008
16300
4777
45000
13189
293 / 620
269 / 570
245 / 520
28 / 61.9
51 / 48 / 47
4.93
18.70
57 / 8.3
49 / 7.1
S12
Products manufactured in an ISO certified facility.
This document contains the most current product information as of this printing.
For the most up-to-date product information, please go to www.mcquay.com.
©2007 McQuay International +1 (800) 432-1342 www.mcquay.com
A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and Refrigeration.