Below you will find brief information for Altivar 61 ATV61H075M3, Altivar 61 ATV61HU15M3, Altivar 61 ATV61HU22M3, Altivar 61 ATV61HU30M3, Altivar 61 ATV61HU40M3. This manual will guide you through the installation process, covering topics like mounting, wiring, and programming. Altivar 61 variable speed drives offer a reliable and efficient solution for controlling asynchronous motors, providing precise speed regulation and enhanced motor protection.
PDF
Document
Advertisement
Advertisement
Altivar 61 Installation manual Variable speed drives for asynchronous motors Retain for future use 0.37 (0.5 HP) ... 45 KW (60 HP)/200 - 240V 0.75 (1 HP) ... 75 KW (100 HP)/380 - 480V Contents Before you begin______________________________________________________________________________________________ 4 Steps for setting up the drive ____________________________________________________________________________________ 5 Preliminary recommendations ___________________________________________________________________________________ 6 Drive ratings _________________________________________________________________________________________________ 8 Dimensions and weights_______________________________________________________________________________________ 10 Mounting and temperature conditions ____________________________________________________________________________ 11 Mounting in a wall-mounted or floor-standing enclosure ______________________________________________________________ 13 Installing the graphic display terminal_____________________________________________________________________________ 15 Position of the charging LED ___________________________________________________________________________________ 16 Installing option cards _________________________________________________________________________________________ 17 Installing the EMC plates ______________________________________________________________________________________ 19 Wiring recommendations ______________________________________________________________________________________ 20 Power terminals _____________________________________________________________________________________________ 22 Control terminals_____________________________________________________________________________________________ 24 Option terminals _____________________________________________________________________________________________ 26 Connection diagrams _________________________________________________________________________________________ 31 Operation on an IT system _____________________________________________________________________________________ 40 Electromagnetic compatibility, wiring _____________________________________________________________________________ 41 3 Before you begin Read and understand these instructions before performing any procedure with this drive. DANGER HAZARDOUS VOLTAGE • Read and understand this manual before installing or operating the Altivar 61 drive. Installation, adjustment, repair, and maintenance must be performed by qualified personnel. • The user is responsible for compliance with all international and national electrical standards in force concerning protective grounding of all equipment. • Many parts of this variable speed drive, including the printed circuit boards, operate at the line voltage. DO NOT TOUCH. Use only electrically insulated tools. • DO NOT touch unshielded components or terminal strip screw connections with voltage present. • DO NOT short across terminals PA and PC or across the DC bus capacitors. • Install and close all the covers before applying power or starting and stopping the drive. • Before servicing the variable speed drive: - Disconnect all power. - Place a “DO NOT TURN ON” label on the variable speed drive disconnect. - Lock the disconnect in the open position. • Disconnect all power including external control power that may be present before servicing the drive. WAIT 15 MINUTES to allow the DC bus capacitors to discharge. Then follow the DC bus voltage measurement procedure on page 16 to verify that the DC voltage is less than 45 V. The drive LEDs are not accurate indicators of the absence of DC bus voltage. Electric shock will result in death or serious injury. CAUTION IMPROPER DRIVE OPERATION • If the drive is not turned on for a long period, the performance of its electrolytic capacitors will be reduced. • If it is stopped for a prolonged period, turn the drive on every two years for at least 5 hours to restore the performance of the capacitors, then check its operation. It is recommended that the drive is not connected directly to the line voltage. The voltage should be increased gradually using an adjustable AC source. Failure to follow these instructions can result in equipment damage. 4 Steps for setting up the drive INSTALLATION b 1 Take delivery of the drive v Check that the catalog number printed on the label is the same as that on the purchase order v Remove the Altivar from its packaging and check that it has not been damaged in transit b 2 Check the line voltage v Check that the line voltage is compatible with the voltage range of the drive (see pages 8 and 9) Steps 1 to 4 must be performed with the power off b 3 Mount the drive v Mount the drive in accordance with the instructions in this document v Install any internal and external options b 4 Wire the drive v Connect the motor, ensuring that its connections correspond to the voltage v Connect the line supply, after making sure that it is turned off v Connect the control v Connect the speed reference PROGRAMMING v 1 Please refer to the programming manual 5 Preliminary recommendations Handling/storage To protect the drive prior to installation, handle and store the device in its packaging. Ensure that the ambient conditions are acceptable. WARNING DAMAGED PACKAGING If the packaging appears damaged, it can be dangerous to open it or handle it. Take precautions against all risks when performing this operation. Failure to follow these instructions can result in death or serious injury. WARNING DAMAGED EQUIPMENT Do not operate or install any drive that appears damaged. Failure to follow these instructions can result in death or serious injury. Handling on installation 45° max. ALTIVAR 61 drives up to ratings ATV61HD15M3X and ATV61HD18N4 can be removed from their packaging and installed without a handling device. A hoist must be used for higher ratings; for this reason they are fitted with handling "lugs”. The following recommendations must be observed. 6 Preliminary recommendations Recommendations Read and understand the instructions in the Programming Manual. CAUTION INCOMPATIBLE LINE VOLTAGE Before turning on and configuring the drive, ensure that the line voltage is compatible with the supply voltage range shown on the drive nameplate. The drive may be damaged if the line voltage is not compatible. Failure to follow these instructions can result in equipment damage. DANGER UNINTENDED EQUIPMENT OPERATION • Before turning on and configuring the Altivar 61, check that the PWR (POWER REMOVAL) input is deactivated (at state 0) in order to prevent unintended operation. • Before turning the drive on or on exiting the configuration menus, check that the inputs assigned to the run command are deactivated (at state 0) since they can cause the motor to start immediately. Failure to follow these instructions will result in death or serious injury. If the safety of personnel requires the prohibition of unwanted or unintended starts, electronic locking is performed by the Altivar 61's Power Removal function. This function requires the use of connection diagrams conforming to category 3 of standard EN 954-1 and safety integrity level 2 according to IEC/EN 61508. The Power Removal function takes priority over any run command. 7 Drive ratings Single-phase supply voltage: 200…240 V 50/60 Hz Three-phase motor 200...240 V Motor Power indicated on plate (1) Line supply (input) Max. line current (2) at 200 V at 240 V kW 0.37 0.75 1.5 2.2 3 4 5.5 A 6.9 12 18.2 25.9 25.9 34.9 47.3 HP 0.5 1 2 3 5 7.5 A 5.8 9.9 15.7 22.1 22 29.9 40.1 Max. Apparent prospective power line Isc kA 5 5 5 5 5 22 22 kVA 1.4 2.4 3.7 5.3 5.3 7 9.5 Drive (output) Max. transient Max. inrush Max. current for 60 s current (3) available nominal (1) current In (1) A A A 9.6 3 3.6 9.6 4.8 5.7 9.6 8 9.6 9.6 11.0 13.2 9.6 13.7 16.4 9.6 17.5 21 23.4 27.5 33 Altivar 61 Catalog number (5) ATV61H075M3(4) ATV61HU15M3(4) ATV61HU22M3(4) ATV61HU30M3(4) ATV61HU40M3(4)(6) ATV61HU55M3(4)(6) ATV61HU75M3(4)(6) Three-phase supply voltage: 200…240 V 50/60 Hz Three-phase motor 200...240 V Motor Power indicated on plate (1) Line supply (input) Max. line current (2) at 200 V at 240 V kW 0.75 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 A 6.1 11.3 15 19.3 25.8 35 45 53.3 71.7 77 88 124 141 167 HP 1 2 3 5 7.5 10 15 20 25 30 40 50 60 A 5.3 9.6 12.8 16.4 22.9 30.8 39.4 45.8 61.6 69 80 110 127 147 Max. Apparent prospective power line Isc kA 5 5 5 5 5 22 22 22 22 22 22 22 22 22 kVA 2.2 4 5.3 6.8 9.2 12.4 15.9 18.8 25.1 27.7 32 42.4 51 65 Drive (output) Max. transient Max. inrush Max. current for 60 s current (3) available nominal (1) current In (1) A A A 9.6 4.8 5.7 9.6 8 9.6 9.6 11 13.2 9.6 13.7 16.4 9.6 17.5 21 23.4 27.5 33 23.4 33 39.6 93.6 54 64.8 93.6 66 79.2 100 75 90 100 88 105.6 250 120 144 250 144 173 250 176 211 Altivar 61 Catalog number (5) ATV61H075M3(4) ATV61HU15M3(4) ATV61HU22M3(4) ATV61HU30M3(4) ATV61HU40M3(4) ATV61HU55M3(4) ATV61HU75M3(4) ATV61HD11M3X(4) ATV61HD15M3X(4) ATV61HD18M3X ATV61HD22M3X ATV61HD30M3X ATV61HD37M3X ATV61HD45M3X (1) These power ratings and currents are given for an ambient temperature of 50°C (122°F) at the factory-set switching frequency, used in continuous operation (factory-set switching frequency of 4 kHz for ATV61H 075M3 to D15M3X and 2.5 kHz for ATV61H D18M3X to D45M3X). Above this factory setting, the drive will reduce the switching frequency automatically in the event of excessive temperature rise. For continuous operation above the factory setting, derating must be applied to the drive nominal current in accordance with the curves on page 12. (2) Current on a line supply with the "Max. prospective line Isc" indicated and for a drive without any external options. (3) Peak current on power-up for the max. voltage (240 V +10%). (4) ATV61H 075M3 to D15M3X drives are available with or without a graphic display terminal. Catalog numbers for drives without a graphic display terminal have the letter Z added at the end, e.g.: ATV61H075M3Z. This option is not available for drives operating in difficult environmental conditions (5). (5) Drives with the S337 or 337 extension are designed for use in difficult environmental conditions (class 3C2 in accordance with IEC 721-3-3). They are supplied with a graphic display terminal. (6) A line choke must be used (please refer to the catalog). Inhibit the input phase loss fault (IPL) so that ATV61H 075M3 to U75M3 drives can operate on a single-phase supply (see the Programming Manual). If this fault is set to its factory configuration, the drive will stay locked in fault mode. 8 Drive ratings Three-phase supply voltage: 380…480 V 50/60 Hz Three-phase motor 380...480 V Motor Line supply (input) Power indicated Max. line current (2) on plate (1) kW 0.75 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 HP 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 at 380 V A 3.7 5.8 8.2 10.7 14.1 20.3 27 36.6 48 45.5 50 66 84 104 120 167 at 480 V A 3 5.3 7.1 9 11.5 17 22.2 30 39 37.5 42 56 69 85 101 137 Max. Apparent prospective power line Isc Drive (output) Max. available nominal Max. Max. current In (1) transient inrush current for current (3) 60 s (1) kA 5 5 5 5 5 22 22 22 22 22 22 22 22 22 22 22 A 19.2 19.2 19.2 19.2 19.2 46.7 46.7 93.4 93.4 93.4 75 90 90 200 200 200 kVA 2.4 4.1 5.6 7.2 9.4 13.7 18.1 24.5 32 30.5 33 44.7 55.7 62.7 81.8 110 at 380 V A 2.3 4.1 5.8 7.8 10.5 14.3 17.6 27.7 33 41 48 66 79 94 116 160 at 460 V A 2.1 3.4 4.8 6.2 7.6 11 14 21 27 34 40 52 65 77 96 124 A 2.7 4.9 6.9 9.3 12.6 17.1 21.1 33.2 39.6 49.2 57.6 79.2 94.8 112.8 139 192 Altivar 61 Catalog number (5) ATV61H075N4(4) ATV61HU15N4(4) ATV61HU22N4(4) ATV61HU30N4(4) ATV61HU40N4(4) ATV61HU55N4(4) ATV61HU75N4(4) ATV61HD11N4(4) ATV61HD15N4(4) ATV61HD18N4 ATV61HD22N4 ATV61HD30N4 ATV61HD37N4 ATV61HD45N4 ATV61HD55N4 ATV61HD75N4 (1) These power ratings and currents are given for an ambient temperature of 50°C (122°F) at the factory-set switching frequency, used in continuous operation (factory-set switching frequency of 4 kHz for ATV61H 075N4 to D30N4 drives, and 2.5 kHz for ATV61H D37N4 to D75N4). Above this factory setting, the drive will reduce the switching frequency automatically in the event of excessive temperature rise. For continuous operation above the factory setting, derating must be applied to the drive nominal current in accordance with the curves on page 12. (2) Current on a line supply with the "Max. prospective line Isc" indicated and for a drive without any external options. (3) Peak current on power-up for the max. voltage (480 V +10%). (4) ATV61H 075N4 to D15N4 drives are available with or without a graphic display terminal. Catalog numbers for drives without a graphic display terminal have the letter Z added at the end, e.g.: ATV61H075N4Z. This option is not available for drives operating in difficult environmental conditions (5). (5) Drives with the S337 or 337 extension are designed for use in difficult environmental conditions (class 3C2 in accordance with IEC 721-3-3). They are supplied with a graphic display terminal. 9 Dimensions and weights With graphic display terminal 2 option cards (1) 1 option card (1) No option card ATV61H a mm (in.) b mm (in.) c mm (in.) c1 mm (in.) c2 mm (in.) G mm (in.) H mm (in.) h mm (in.) Ø mm (in.) For screws Weight kg (lb.) 075M3, U15M3, 075N4, U15N4,U22N4 U22M3, U30M3, U40M3, U30N4, U40N4 U55M3, U55N4, U75N4 130 (5.12) 230 (9.05) 175 (6.89) 198 (7.80) 221 (8.70) 113.5 (4.47) 220 (8.66) 5 (0.20) 5 (0.20) M4 3 (6.61) 155 (6.10) 260 (10.23) 187 (7.36) 210 (8.27) 233 (9.17) 138 (5.43) 249 (9.80) 4 (0.16) 5 (0.20) M4 4 (8.82) 175 (6.89) 295 (11.61) 187 (7.36) 210 (8.27) 233 (9.17) 158 (6.22) 283 (11.14) 6 (0.24) 5 (0.20) M4 5.5 (12.13) U75M3, D11N4 210 (8.27) 295 (11.61) 213 (8.39) 236 (9.29) 259 (10.20) 190 (7.48) 283 (11.14) 6 (0.24) 6 (0.24) M5 7 (15.43) D11M3X, D15M3X, D15N4, D18N4 D18M3X, D22M3X, D22N4 230 (9.05) 400 (15.75) 213 (8.39) 236 (9.29) 259 (10.20) 210 (8.26) 386 (15.20) 8 (0.31) 6 (0.24) M5 9 (19.84) 240 (9.45) 420 (16.54) 236 (9.29) 259 (10.20) 282 (11.10) 206 (8.11) 403 (15.87) 11 (0.45) 6 (0.24) M5 30 (66.14) D30N4, D37N4 240 (9.45) 550 (21.65) 266 (10.47) 289 (11.38) 312 (12.28) 206 (8.11) 531.5 (20.93) 11 (0.45) 6 (0.24) M5 37 (81.57) D30M3X, D37M3X, D45M3X 320 (12.60) 550 (21.65) 266 (10.47) 289 (11.38) 312 (12.28) 280 (11.02) 524 (20.93) 20 (0.79) 9 (0.35) M8 37 (81.57) D45N4, D55N4, D75N4 320 (12.60) 630 (24.80) 290 (11.42) 313 (12.32) 334 (13.15) 280 (11.02) 604.5 (23.80) 15 (0.59) 9 (0.35) M8 45 (99.21) Without graphic display terminal 2 option cards (1) 4x c H b 1 option card (1) h No option card c1 c2 = G a = For a drive without a graphic display terminal, dimensions c, c1 and c2 in the table above are reduced by 26 mm (1.01 in.). The other dimensions are unchanged. (1) For the addition of I/O extension cards, communication cards, or the "Controller Inside" programmable card. 10 u 3.94 in. u 100 mm Mounting and temperature conditions Install the drive vertically at ± 10°. Do not place it close to heating elements. Leave sufficient free space to ensure that the air required for cooling purposes can circulate from the bottom to the top of the unit. Free space in front of the drive: 10 mm (0.39 in.) minimum u 3.94 in. u 100 mm When IP20 protection is adequate, it is recommended that the protective cover on the top of the drive is removed as shown below. Removing the protective cover ATV61H 075M3 to D15M3X and ATV61H 075N4 to D18N4 ATV61H D18M3X to D45M3X and ATV61H D22N4 to D75N4 2 types of mounting are possible: Type A mounting Type B mounting Free space u 50 mm (u 1.97 in.) on each side, with protective cover fitted u 50 mm u 50 mm u 1.97 in. u 1.97 in. Drives mounted side by side, with the protective cover removed (the degree of protection becomes IP20) 11 Mounting and temperature conditions Derating curves Derating curves for the drive current In as a function of the temperature, switching frequency and type of mounting. ATV61H 075M3 to D15M3X and ATV61H 075N4 to D18N4 I/In In = 100 % 90 % 40°C (104°F) mounting type A 50°C (122°F) mounting type B 80 % 50°C (122 °F) mounting type A 70 % 60°C (140°F) mounting types A and B 60 % 50 % 4 kHz 8 kHz 12 kHz 16 kHz Switching frequency ATV61H D22N4 and ATV61H D30N4 I/In In = 100 % 40°C (104°F) 90 % 80 % 50°C (122°F) 70 % 60 % 60°C (140°F) 50 % 4 kHz 8 kHz 12 kHz 16 kHz Switching frequency ATV61H D18M3X to D45M3X and ATV61H D37N4 to D75N4 I/In In = 100 % 40°C (104°F) 90 % 80 % 50°C (122°F) 70 % 60 % 60°C (140°F) 50 % 2,5 kHz 4 kHz 8 kHz 12 kHz 16 kHz Switching frequency For intermediate temperatures (e.g. 55°C (131°F)), interpolate between 2 curves. 12 Mounting in a wall-mounted or floor-standing enclosure Follow the mounting recommendations on the previous pages. To ensure good air circulation in the drive: - Use ventilation grilles - Ensure that the ventilation is adequate: if not, install forced ventilation with a filter - Use special IP54 filters Dust and damp proof metal wall-mounted or floor-standing enclosure (IP 54 degree of protection) The drive must be mounted in a dust and damp proof enclosure in certain environmental conditions: dust, corrosive gases, high humidity with risk of condensation and dripping water, splashing liquid, etc. To avoid hot spots in the drive, add a fan to circulate the air inside the enclosure, catalog number VW3 A9 4pp (see catalog). Mounting the drive in the enclosure Dissipated power These power ratings are given for operation at nominal load and for the factory-set switching frequency. ATV61H 075M3 U15M3 U22M3 U30M3 U40M3 U55M3 U75M3 D11M3X D15M3X D18M3X D22M3X D30M3X D37M3X D45M3X Dissipated power (1) W 66 101 122 154 191 293 363 566 620 799 865 1134 1337 1567 ATV61H 075N4 U15N4 U22N4 U30N4 U40N4 U55N4 U75N4 D11N4 D15N4 D18N4 D22N4 D30N4 D37N4 D45N4 D55N4 D75N4 Dissipated power (1) W 44 64 87 114 144 178 217 320 392 486 717 976 1174 1360 1559 2326 (1) Add 7W to this value for each option card added Ensure that the flow of air in the enclosure is at least equal to the value given in the table below for each drive. Flow rate ATV61H 3 075M3, U15M3, 075N4, U15N4, U22N4 U22M3, U30M3, U40M3, U30N4, U40N4 U55M3, U55N4, U75N4 U75M3, D11N4 D11M3X, D15M3X, D15N4, D18N4 D18M3X, D22M3X, D22N4 D30N4, D37N4 D30M3X, D37M3X, D45M3X D45N4, D55N4, D75N4 m /hour 17 ft3/min 10 56 33 112 163 252 66 96 148 203 119 203 406 406 119 239 239 13 Mounting in a wall-mounted or floor-standing enclosure Dust and damp proof flange mounting This mounting is used to reduce the power dissipated in the enclosure by locating the power section outside the enclosure. This requires the use of a dust and damp proof flange mounting kit VW3 A9 501...509 (please refer to the catalog). The degree of protection for the drives mounted in this way becomes IP54. To fit the kit to the drive, please refer to the manual supplied with the kit. Example: ATV61HU55N4 Power dissipated inside the enclosure for dust and damp proof flange mounting These power ratings are given for operation at nominal load and for the factory-set switching frequency. ATV61H 075M3 U15M3 U22M3 U30M3 U40M3 U55M3 U75M3 D11M3X D15M3X D18M3X D22M3X D30M3X D37M3X D45M3X Dissipated power (1) W 28 35 39 41 48 71 81 120 137 291 294 368 447 452 ATV61H 075N4 U15N4 U22N4 U30N4 U40N4 U55N4 U75N4 D11N4 D15N4 D18N4 D22N4 D30N4 D37N4 D45N4 D55N4 D75N4 (1) Add 7W to this value for each option card added 14 Dissipated power (1) W 28 31 35 43 48 54 64 76 100 134 298 354 441 538 592 958 Installing the graphic display terminal Installing the graphic display terminal on the drive Drives with catalog numbers ending in the letter Z are supplied without a graphic display terminal (VW3 A1 101). This can be ordered separately. It is installed on the drive as shown below. The graphic display terminal can be connected or disconnected with the power on. Before disconnecting it, drive control via the display terminal must be disabled (refer to the Programming Manual). 15 Position of the charging LED Before working on the drive, turn it off, wait until the red capacitor charging LED has gone out, then measure the DC bus voltage. Position of the capacitor charging LED ATV61H 075M3 to D15M3X and ATV61 075N4 to D18N4 ATV61H D18M3 to D45M3X and ATV61H D22N4 to D75N4 Red LED indicating that the DC bus is turned on Procedure for measuring the DC voltage DANGER HAZARDOUS VOLTAGE Read and understand the instructions on page 4 before performing this procedure. Failure to follow this instruction will result in death or serious injury. The DC bus voltage can exceed 1,000 V c. Use a properly rated voltage sensing device when performing this procedure. To measure the DC bus voltage: 1 Disconnect the drive power supply. 2 Wait 15 minutes to allow the DC bus capacitors to discharge. 3 Measure the voltage of the DC bus between the PA/+ and PC/- terminals to check whether the voltage is less than 45 V c. See page 23 for the arrangement of the power terminals. 4 If the DC bus capacitors have not discharged completely, contact your local Schneider Electric representative (do not repair or operate the drive). 16 Installing option cards These should ideally be installed once the drive is mounted and before wiring it. Check that the red capacitor charging LED has gone out. Measure the DC bus voltage in accordance with the procedure indicated on page 16. The option cards are installed under the drive control front panel. If the drive has a graphic display terminal, remove it, then remove the control front panel as indicated below. Remove the control front panel 1 • Using a screwdriver, press down on the catch and pull to release the lefthand part of the control front panel 2 3 • Do the same on the right-hand side • Pivot the control front panel and remove it Installing an encoder interface card There is a special slot on the drive for adding an encoder interface card. If an I/O or communication option card or a "Controller Inside" programmable card has already been installed, remove it so you can access the slot for the encoder interface card. 17 Installing option cards Installing an I/O extension card, a communication card or a "Controller Inside" programmable card 6 5 1 , 2 and 3 Remove the control front panel (see previous page) 4 Install an encoder interface card (if used) (see previous page) 5 Position the option card on the clasps 6 Then pivot it until it clicks into place 7 7 Replace the control front panel over the option card (same procedure as for installing the option card, see 5 and 6 ) 18 Installing the EMC plates ATV61H 075M3 to D15M3X and ATV61H 075N4 to D18N4 ATV61H D18M3X to D45M3X and ATV61H D22N4 to D75N4 3 3 5 4 4 2 4 4 6 1 1 6 Installing the EMC clamps 6 - EMC plate for connecting the power cables - EMC plate for connecting the control cables (only for ATV61H 075M3 to D15M3X and ATV61H 075N4 to D18N4) - EMC plate for connecting the I/O option card cables (supplied with the option cards) - M4 screws (supplied) - M8 screws (supplied) - EMC clamps with captive screws (supplied) Δb ATV61H Δb 1 2 3 4 5 6 075M3, U15M3,U22M3, U30N4, U40M3, 075N4, U15N4, U22N4, U30N4, U40N4 U55M3, U75M3, D11M3X, D15M3X, U55N4, U75N4, D11N4, D15N4, D18N4 D18M3X, D22M3X, D22N4, D30N4, D37N4D30M3X, D37M3X, D45M3X, D45N4, D55N4, D75N4 mm in. 55 2.17 65 2.56 120 4.72 19 Wiring recommendations Power The drive must be connected to the protective ground. To comply with current regulations concerning high leakage currents (above 3.5 mA), use at least a 10 mm² (AWG 6) protective conductor or 2 protective conductors with the same cross-section as the power supply conductors. DANGER HAZARDOUS VOLTAGE Ground equipment using the provided ground connecting point as shown in the figure below. The drive panel must be properly grounded before power is applied. Failure to follow these instructions will result in death or serious injury. Drive • Check whether the resistance to the protective ground is one ohm or less. Connect a number of drives to the protective ground, as shown in the diagram (see left). Do not lay protective grounding cables in a loop or in series. Drive Drive WARNING IMPROPER WIRING PRACTICES • The ATV61 drive will be damaged if input line voltage is applied to the output terminals (U/T1,V/T2,W/T3). • Check the power connections before energizing the ATV61 drive. • If replacing another drive, verify that all wiring connections to the ATV61 drive comply with all wiring instructions in this manual. Failure to follow these instructions can result in death or serious injury. When upstream protection by means of a "residual current device" is required by the installation standards, a type A device should be used for single-phase drives and type B for three-phase drives. Choose a suitable model integrating: • HF current filtering • A time delay which prevents tripping caused by the load from stray capacitance on power-up. The time delay is not possible for 30 mA devices. In this case, choose devices with immunity against nuisance tripping, for example "residual current devices" with reinforced immunity from the s.i range (Merlin Gerin brand). If the installation includes several drives, provide one residual current device per drive. WARNING INADEQUATE OVERCURRENT PROTECTION • Overcurrent protective devices must be properly coordinated. • The Canadian Electricity Code and the National Electrical Code require branch circuit protection. Use the fuses recommended on the drive nameplate to achieve published short-circuit current ratings. • Do not connect the drive to a power feeder whose short-circuit capacity exceeds the drive short-circuit current rating listed on the drive nameplate. Failure to follow these instructions can result in death or serious injury. 20 Wiring recommendations Keep the power cables separate from circuits in the installation with low-level signals (sensors, PLCs, measuring apparatus, video, telephone). The motor cables must be at least 0.5 m (20 in.) long. Do not immerse the motor cables in water. Do not use surge arresters or power factor correction capacitors on the variable speed drive output. CAUTION IMPROPER USE OF A BRAKING RESISTOR • Only use the braking resistors recommended in our catalogs. • Wire the thermal protection contact on the resistor so that the drive power supply is disconnected immediately in the event of a fault (refer to the manual supplied with the resistor). Failure to follow these instructions can result in equipment damage. Control Keep the control circuits away from the power circuits. For control and speed reference circuits, we recommend using shielded twisted cables with a pitch of between 25 and 50 mm (0.98 and 1.97 in.) and connecting the shielding to ground at each end. If using conduit, do not lay the motor, power supply and control cables in the same conduit. Keep the metal conduit containing the power supply cables at least 8 cm (3 in.) away from the metal conduit containing the control cables. Keep the non-metal conduits or cable ducts containing the power supply cables at least 31 cm (12 in.) away from the metal conduits containing the control cables. If it is necessary for control and power cables to cross each other, be sure they cross at right angles. Length of motor cables ATV61H 0m (0 ft) 075M3 to U75M3 075N4 to D15N4 D11M3X to D45M3X D18N4 to D75N4 50 m (164 ft) 100 m (328 ft) 150 m (492 ft) 300 m (984 ft) 1,000 m (3,280 ft) Shielded cable Unshielded cable Shielded cable Unshielded cable with dv/dt filters with output filters Choice of associated components: Please refer to the catalog. 21 Power terminals Access to the power terminals ATV61 H075M3 to HD15M3X and ATV61 H075N4 to HD18N4 Unlock the power part access flap and remove it as shown below. Example of ATV61HU22M3 ATV61 HD18M3X to HD45M3X and ATV61 HD22N4 and HD75N4 To access the power terminals, remove the front panel as shown below. Example of ATV61HD75N4 Characteristics and functions of the power terminals Terminal t R/L1 S/L2 T/L3 PO PA/+ PB PC/U/T1 V/T2 W/T3 Function Protective ground connection terminal Power supply DC bus + polarity Output to braking resistor (+ polarity) Output to braking resistor DC bus - polarity Outputs to the motor Only remove the link between PO and PA/+ if a DC choke has been added. The screws on the PO and PA/+ terminals must always be fully tightened as there is a high current flowing in the commoning link. 22 Power terminals Arrangement of the power terminals ATV61H 075M3, U15M3, U22M3, U30M3, U40M3, 075N4, U15N4, U22N4, U30N4, U40N4 ATV61H PO PA/+ PB R/L1 S/L2 T/L3 075M3, U15M3, 075N4, U15N4, U22N4 U22M3, U30M3, U40M3, U30N4, U40N4 PC/U/T1 Maximum wire size mm² AWG 2.5 14 6 8 Tightening torque Nm (lb.in) 1.2 (10.6) 1.2 (10.6) V/T2 W/T3 ATV61H U55M3, U75M3, D11M3X, D15M3X, U55N4, U75N4, D11N4, D15N4, D18N4 ATV61H U55M3, U55N4, U75N4 U75M3, D11N4 D11M3X, D15M3X, D15N4, D18N4 R/L1 S/L2 T/L3 PO PA/+ PB PC/- U/T1 Maximum wire size mm² AWG 10 6 16 4 35 1 Tightening torque Nm (lb.in) 2 (17.7) 2.4 (21) 2.4 (21) V/T2 W/T3 ATV61H D18M3X, D22M3X, D30M3X, D37M3X, D45M3X, D22N4, D30N4, D37N4, D45N4, D55N4, D75N4 ATV61H D18M3X, D22M3X, D22N4, D30N4, D37N4 ATV61H R/L1 S/L2 T/L3 U/T1 V/T2 W/T3 PO PB PC/- PA/+ D30M3X, D37M3X, D45M3X, D45N4, D55N4, D75N4 Maximum wire size mm² AWG 50 1/0 Maximum wire size mm² kcmils 120 350 Tightening torque Nm (lb.in) 6 (53) Tightening torque Nm (lb.in) 19 (168) 23 Control terminals Access to the control terminals To access the control terminals, open the cover on the control front panel. Removing the terminal card 1 To make it easier to wire the drive control section, the control terminal card can be removed. • Undo the screw until the spring is fully extended • Remove the card by sliding it downwards CAUTION 2 IMPROPERLY SECURED TERMINAL CARD When replacing the control terminal card, it is essential to fully tighten the captive screw. Failure to follow this instruction can result in equipment damage. Arrangement of the control terminals Logic input switch Source SW1 Sink AO1 AI2 COM +10 AI1+ AI1COM R1C R2A R2C Factory setting: Source Ext SW2 R1A R1B Int LI6 input switch Factory setting: LI LI5 LI6 +24 PWR LI2 LI3 LI4 P24 0V LI1 PTC LI RJ45 RJ45 connector Note: The ATV61 is supplied with a link between the PWR and +24 terminals. 24 Maximum wire size: 2.5 mm² - AWG 14 Max. tightening torque: 0.6 Nm - 5.3 lb.in Control terminals Characteristics and functions of the control terminals Terminal R1A R1B R1C R2A R2C Electrical characteristics • Minimum switching capacity: 3 mA for 24 V c • Maximum switching capacity on resistive load: 5 A for 250 V a or 30 V c • Maximum switching current on inductive load (cos ϕ = 0.4 L/R = 7 ms): N/O contact of programmable relay R2 2 A for 250 V a or 30 V c • Reaction time: 7 ms ± 0.5 ms • Service life: 100,000 operations at max. switching power +10 + 10 V c power supply for reference potentiometer 1 to 10 kΩ Differential analog input AI1 AI1+ AI1 COM AI2 COM AO1 P24 0V LI1 LI2 LI3 LI4 LI5 LI6 +24 PWR Function Common point C/O contact (R1C) of programmable relay R1 • + 10 V c (10.5 V ± 0.5V) • 10 mA max. • -10 to +10 V c (max. safe voltage 24 V) • Reaction time: 2 ms ± 0.5 ms, 11-bit resolution + 1 sign bit • Accuracy ± 0.6% for Δθ = 60°C (140°F), linearity ± 0.15% of max. value 0V Analog I/O common Depending on software configuration: Analog voltage input • Analog input 0 to +10 V c (max. safe voltage 24 V), impedance 30 kΩ or or Analog current input • Analog input X - Y mA, X and Y can be programmed from 0 to 20 mA, impedance 250 Ω • Reaction time: 2 ms ± 0.5 ms • 11-bit resolution, accuracy ± 0.6% for Δθ = 60°C (140°F), linearity ± 0.15% of max. value Analog I/O common 0V Depending on software configuration: Analog voltage output • Analog output 0 to +10 V c, load impedance greater than 50 kΩ or or Analog current output • Analog output X - Y mA, X and Y can be programmed from 0 to 20 mA, max. load impedance 500 Ω • 10-bit resolution, reaction time: 2 ms ± 0.5 ms • Accuracy ± 1% for Δθ = 60°C (140°F), linearity ± 0,2% of max. value Input for external +24V c control power supply Logic input common and 0V of P24 external power supply Programmable logic inputs • +24 V c (min. 19 V, max. 30 V) • Power 30 Watts 0V • +24 V c (max. 30 V) • Impedance 3.5 kΩ • Reaction time: 2 ms ± 0.5 ms SW1 switch State 0 State 1 Source (factory setting) < 5 V c > 11 V c Sink Int or Sink Ext > 16 V c < 10 V c Depending on the position of the SW2 switch. SW2 switch on LI (factory setting) - Programmable logic input • Same characteristics as logic inputs LI1 to LI5 or or SW2 switch on PTC - Input for PTC probes • Trip threshold 3 kΩ, reset threshold 1.8 kΩ • Short-circuit detection threshold < 50 Ω Logic input power supply SW1 switch in Source or Sink Int position • +24 V c power supply (min. 21 V, max. 27 V), protected against short-circuits and overloads • Max. current available for customers 200 mA Power Removal safety function input When PWR is not connected to the 24V, the motor cannot be started (compliance with functional safety standard EN 954-1 and IEC/EN 61508) SW1 switch in Sink Ext position • Input for external +24 V c power supply for the logic inputs • 24 V c power supply (max. 30 V) • Impedance 1.5 kΩ • State 0 if < 2V, state 1 if > 17V • Reaction time: 10ms 25 Option terminals Logic I/O option card terminals (VW3 A3 201) Logic input switch SW3 Source SW3 Sink Factory setting: Source Ext Int TH1+ TH1L01 L02 CLO 0V -10 +24 LI7 LI8 LI9 LI10 0V R3C R3A R3B Maximum wire size: 1.5 mm² - AWG 16 Max. tightening torque: 0.25 Nm - 2.21 lb.in Characteristics and functions of the terminals Terminal R3A R3B R3C Function Common point C/O contact R3C of programmable relay R3 Electrical characteristics • Minimum switching capacity: 3mA for 24 V c • Maximum switching capacity on resistive load: 5 A for 250 V a or 30 V c • Maximum switching capacity on inductive load (cos ϕ = 0.4 L/R = 7 ms): 2 A for 250 V a or 30 V c • Reaction time: 7 ms ± 0.5 ms • Service life: 100,000 operations -10 -10 V c power supply for reference potentiometer 1 to 10 kΩ Logic input power supply • - 10 V c (-10.5 V ± 0.5V) • 10 mA max. SW3 switch in Source or Sink Int position • +24 V c power supply (min. 21 V, max. 27 V), protected against short-circuits and overloads • Max. current available for customers 200 mA (This current corresponds to the total consumption on the control card +24 and the option cards +24) +24 SW3 switch in Sink Ext position • Input for external +24 V c power supply for the logic inputs • +24 V c power supply (max. 30 V) Switch SW3 State 0 State 1 • Impedance 3.5 kΩ • Reaction time 2 ms ± 0.5 ms Source (factory setting) < 5 V c > 11 V c Sink Int or Sink Ext > 16 V c < 10 V c LI7 LI8 LI9 LI10 Programmable logic inputs 0V 0V 0V TH1+ TH1LO1 LO2 PTC probe input • Trip threshold 3 kΩ, reset threshold 1.8 kΩ • Short-circuit detection threshold < 50 Ω Open collector programmable logic outputs • +24 V c (max. 30 V) • Max. current 200 mA for internal power supply and 200 mA for external power supply • Reaction time: 2 ms ± 0.5 ms CLO 0V Logic output common 0V 26 0V Option terminals Extended I/O option card terminals (VW3 A3 202) Logic input switch SW4 Factory setting: Source Source Sink Ext Int SW4 0V CLO LO4 LO3 RP TH2TH2+ +24 LI11 LI12 LI13 LI14 0V -10 AI3+ AI3AI4 COM AO2 AO3 R4C R4B R4A Maximum wire size: 1.5 mm² - AWG 16 Max. tightening torque: 0.25 Nm - 2.21 lb.in Characteristics and functions of the terminals Terminal R4A R4B R4C Function Common point C/O contact R4C of programmable relay R4 Electrical characteristics • Minimum switching capacity: 3mA for 24 V c • Maximum switching capacity on resistive load: 5 A for 250 V a or 30 V c • Maximum switching capacity on inductive load (cos ϕ = 0.4 L/R = 7 ms): 1.5 A for 250 V a or 30 V c • Reaction time 10 ms ± 1ms • Service life: 100,000 operations -10 -10 V c power supply for reference potentiometer 1 to 10 kΩ + polarity of the current differential analog input AI3 - polarity of the current differential analog input AI3 • - 10 V c (-10.5 V ± 0.5V) • 10 mA max. • Analog input X - Y mA, X and Y can be programmed from 0 to 20 mA, impedance 250 Ω • Reaction time: 5 ms ± 1 ms • 11-bit resolution + 1 sign bit, accuracy ± 0.6% for Δθ = 60°C (140°F) • Linearity ± 0.15% of max. value AI3 + AI3 AI4 COM AO2 AO3 Depending on software configuration: Analog current input • Analog input 0 to +10 V c (max. safe voltage 24 V), impedance 30 kΩ or or Analog voltage input • Analog input X - Y mA, X and Y can be programmed from 0 to 20 mA, impedance 250 Ω • Reaction time: 5 ms ± 1 ms • 11-bit resolution, accuracy ± 0.6% for Δθ = 60°C (140°F), linearity ± 0.15% of max. value Analog I/O common 0V Depending on software configuration: Analog voltage outputs • 0 - 10 V c bipolar analog output or -10/+10 V c depending on software, load impedance greater than 50 kΩ or or Analog current outputs • Analog current output X-Y mA, X and Y can be programmed from 0 to 20 mA, max. load impedance 500 Ω • 10-bit resolution • Reaction time 5 ms ± 1 ms, accuracy ± 1% for Δθ = 60°C (140°F), linearity ± 0.2% 27 Option terminals Terminal +24 Function Logic input power supply Electrical characteristics SW4 switch in Source or Sink Int position • +24 V c output (min. 21 V, max. 27 V), protected against short-circuits and overloads • Max. current available for customers 200 mA (This current corresponds to the total consumption on the control card +24 and the option cards +24) SW4 switch in Sink Ext position • Input for external +24 V c power supply for the logic inputs • +24 V c (max. 30 V) SW4 switch State 0 State 1 • Impedance 3.5 kΩ • Reaction time: 5 ms ± 1 ms Source (factory setting) < 5 V c > 11 V c Sink Int or Sink Ext > 16 V c < 10 V c LI11 LI12 LI13 LI14 Programmable logic inputs 0V Logic input common 0V TH2 + TH2 RP PTC probe input • • • • • • • LO3 LO4 CLO 0V 28 Frequency input Trip threshold 3 kΩ, reset threshold 1.8 kΩ Short-circuit detection threshold < 50 Ω Frequency range: 0…30 kHz Cyclic ratio: 50 % ± 10 % Maximum sampling time: 5 ms ± 1 ms Maximum input voltage 30 V, 15 mA Add a resistor if the input voltage is greater than 5 V (510 Ω for 12 V, 910 Ω for 15 V, 1.3 kΩ for 24 V) State 0 if < 1.2 V, state 1 if > 3.5 V +24 V c (max. 30 V) Max. current 20 mA for internal power supply and 200 mA for external power supply Reaction time 5 ms ± 1ms • Open collector programmable logic • outputs • • Logic output common 0V 0V Option terminals Encoder interface card terminals VW3 A3 401...407 0Vs +Vs B B A A Maximum wire size: 1.5 mm² - AWG 16 Max. tightening torque: 0.25 Nm - 2.21 lb.in Characteristics and functions of the terminals Encoder interface cards with RS422-compatible differential outputs Terminal Function Electrical characteristics VW3 A3 401 +Vs Encoder power • 5V c (max. 5.5V) protected against short-circuits supply and overloads 0Vs • Max. current 200 mA A, /A Incremental • Max. resolution: 5,000 points/rev B, /B logic inputs • Max. frequency: 300kHz VW3 A3 402 • 15 V c (max. 16 V) protected against short-circuits and overloads • Max. current 175 mA Encoder interface cards with open collector outputs Terminal Function Electrical characteristics VW3 A3 403 VW3 A3 404 +Vs Encoder power • 12 V c (max. 13 V) protected against short-circuits • 15 V c (max. 16 V) protected against short-circuits supply and overloads and overloads 0Vs • Max. current 175 mA • Max. current 175 mA A, /A Incremental • Max. resolution: 5,000 points/rev B, /B logic inputs • Max. frequency: 300kHz Encoder interface cards with push-pull outputs Terminal Function Electrical characteristics VW3 A3 405 VW3 A3 406 +Vs Encoder power • 12 V c (max. 13 V) protected • 15 V c (max. 16 V) protected supply against short-circuits and against short-circuits and 0Vs overloads overloads • Max. current 175 mA • Max. current 175 mA A, /A Incremental • Max. resolution: 5,000 points/rev B, /B logic inputs • Max. frequency: 300kHz VW3 A3 407 • 24V c (min. 20V, max. 30V) protected against short-circuits and overloads • Max. current 100 mA 29 Option terminals Selecting the encoder The 7 encoder interface cards available as options with the ATV61 enable three different encoder technologies to be used: • Optical incremental encoder with differential outputs compatible with the RS422 standard • Optical incremental encoder with open collector outputs • Optical incremental encoder with push pull-outputs The encoder must comply with the following two limits: • Maximum encoder frequency 300 kHz • Maximum resolution 5,000 points/revolution Choose the max. standard resolution within these two limits to obtain optimum accuracy. Wiring the encoder Use a shielded cable containing 3 twisted pairs with a pitch of between 25 and 50 mm (0.98 in. and 1.97 in.). Connect the shielding to ground at both ends. The minimum cross-section of the conductors must comply with the table below to limit line voltage drop: Max. encoder cable length 10 m 32.8 ft 50 m 164 ft 100 m 328 ft 200 m 656 ft 300 m 984 ft 30 VW3 A3 401...402 Max. consumption Minimum cross-section of current of encoder conductors 100 mA 0.2 mm² AWG 24 200 mA 0.2 mm² AWG 24 100 mA 0.5 mm² AWG 20 200 mA 0.75 mm² AWG 18 100 mA 0.75 mm² AWG 18 200 mA 1.5 mm² AWG 15 - VW3 A3 403...407 Max. consumption Minimum cross-section of current of encoder conductors 100 mA 0.2 mm² AWG 24 200 mA 0.2 mm² AWG 24 100 mA 0.5 mm² AWG 20 200 mA 0.75 mm² AWG 18 100 mA 0.75 mm² AWG 18 200 mA 1.5 mm² AWG 16 100 mA 0.5 mm² AWG 20 200 mA 1.5 mm² AWG 15 100 mA 0.75 mm² AWG 18 200 mA 1.5 mm² AWG 15 Connection diagrams Connection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance with standard IEC/EN 60204 1 Single-phase power supply (ATV61H 075M3 to U75M3) Diagram with line contactor 2a - Q2 - Q3 - T1 - S2 - S1 - KM1 A1 A2 - Q2 A1 - KM1 R1A - KM1 R1C (1) +24 PWR R2C R2A R1B PB PC / - R1C R1A PA / + T / L3 W / T3 P0 S / L2 ATV61HpppM3 W1 R / L1 U / T1 V1 U1 V / T2 (2) A1 M 3a Braking resistor (if used) Diagram with switch disconnect 2 a (1) +24 PWR R2C R2A R1B PC / - PB PA / + R1C R1A T / L3 W / T3 P0 S / L2 R / L1 U / T1 V / T2 (2) A1 ATV61HpppM3 W1 V1 U1 Q1 Braking resistor (if used) M 3a (1) Line choke, if used (compulsory for ATV61H U40M3 to U75M3 drives) (2) Fault relay contacts, for remote signaling of drive status Inhibit the input phase loss fault (IPL) so that ATV61H 075M3 to U75M3 drives can operate on a single-phase supply (see the Programming Manual). If this fault is set to its factory configuration, the drive will stay locked in fault mode. Note: Install interference suppressors on all inductive circuits near the drive or connected to the same circuit (relays, contactors, solenoid valves, etc). Choice of associated components: Please refer to the catalog. 31 Connection diagrams Connection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance with standard IEC/EN 60204-1 Three-phase power supply Diagram with line contactor 3a - Q2 - S2 - Q3 - T1 - S1 - KM1 A1 A2 - Q2 A1 - KM1 - KM1 R1A R1C (1) +24 PC / - PWR R2C R2A PB R1B PA / + W1 P0 R1C T / L3 W / T3 S / L2 R / L1 V / T2 U / T1 V1 U1 R1A (2) A1 M 3a Braking resistor (if used) Diagram with switch disconnect 3a (1) +24 PWR R2C PC / - PB R2A PA / + R1C R1B P0 R1A T / L3 S / L2 V / T2 W / T3 R / L1 U / T1 (2) A1 W1 V1 U1 Q1 Braking resistor (if used) M 3a (1) Line choke (if used) (2) Fault relay contacts, for remote signaling of drive status Note: Fit interference suppressors to all inductive circuits near the drive or coupled to the same circuit (relays, contactors, solenoid valves, etc). Choice of associated components: Please refer to the catalog. 32 Connection diagrams Connection diagrams conforming to standards EN 954-1 category 3 and IEC/EN 61508 capacity SIL2, stopping category 0 in accordance with standard IEC/EN 60204-1 This connection diagram is suitable for use with machines with a short freewheel stop time (machines with low inertia or high resistive torque). When the stop request is activated, the motor power supply is cut immediately and it stops is accordance with category 0 of standard IEC/EN 60204-1. N(-) L1(+) F1 S2 S1 ESC A1 3a Y1 Y2 13 23 33 Y43 14 24 34 Y44 XPS AC K1 Logic T K2 48 V, 115 V, 230 V A2 K1 K2 PE (1) R1B R1C R1A +24 PWR LI1 LI6 PC / - PB PA / + P0 T / L3 W / T3 S / L2 W1 V / T2 V1 U1 U / T1 R / L1 A1 LI2 (2) M 3a Braking resistor (if used) (1) Line choke (if used) (2) It is essential to connect the shielding on the cable connected to the Power Removal input to ground. - Standard EN 954-1 category 3 requires the use of a stop button with double contact (S1). - S1 is used to activate the Power Removal safety function. - S2 is used to initialize the Preventa module when powering up or after an emergency stop. ESC enables the use of other initialization conditions for the module. - One Preventa module can be used for the Power Removal safety function on several ATV61 drives. - A logic input on the Preventa module can be used to indicate safely that the drive is operating in safe conditions. Note: For preventive maintenance, the Power Removal function must be activated at least once a year. The drive power supply must be turned off and then on again before carrying out this preventive maintenance. The drive logic output signals cannot be considered as safety-type signals. Fit interference suppressors to all inductive circuits near the drive or coupled to the same circuit (relays, contactors, solenoid valves, etc). Choice of associated components: Please refer to the catalog. 33 Connection diagrams Connection diagrams conforming to standards EN 954-1 category 3 and IEC/EN 61508 capacity SIL2, stopping category 1 in accordance with standard IEC/EN 60204-1 This connection diagram is suitable for use with machines with a long freewheel stop time (machines with high inertia or low resistive torque). When the stop request is activated, deceleration of the motor, controlled by the drive, is requested first. Then, after a time delay corresponding to the deceleration time, the Power Removal safety function is activated. Example: - 2-wire control - LI1 assigned to forward - LI2 assigned to reverse N(-) L1(+) F1 S1 A1 S21 S11 B1 XPS AT T - 13 23 33 41 S12 S22 K1 K1 K3 K1 67 58 68 K3 1 2 + 115 V 230 V 3a 57 Logic K2 K2 K4 K1 K4 K2 K3 K2 K4 A2 S33 PE Y1 Y2 Y3 Y4 Y5 14 24 34 42 ESC S2 (1) (2) R1B R1A R1C +24 PWR LI1 LI6 PC / - PB PA / + P0 T / L3 W / T3 S / L2 W1 V / T2 V1 U1 U / T1 R / L1 A1 LI2 (3) M 3a Braking resistor (if used) (1) In this example, the logic inputs LIp are wired as "Source" but can be wired as "Sink Int" or "Sink Ext". (2) Line choke (if used) (3) It is essential to connect the shielding on the cable connected to the Power Removal input to ground. - Standard EN 954-1 category 3 requires the use of a stop button with double contact (S1). - S1 is used to activate the Power Removal safety function. - S2 is used to initialize the Preventa module when powering up or after an emergency stop. ESC enables the use of other initialization conditions for the module. - One Preventa module can be used for the Power Removal safety function on several ATV61 drives. In this case the time delay must be set to the longest stopping time. - A logic input on the Preventa module can be used to indicate safely that the drive is operating in safe conditions. Note: For preventive maintenance, the Power Removal function must be activated at least once a year. The drive power supply must be turned off and then on again before carrying out this preventive maintenance. The drive logic output signals cannot be considered as safety-type signals. Fit interference suppressors to all inductive circuits near the drive or coupled to the same circuit (relays, contactors, solenoid valves, etc). Choice of associated components: Please refer to the catalog. 34 Connection diagrams Control connection diagrams Control card connection diagram A1 COM AO1 COM AI 2 AI1- AI1+ +10 0V LI6 LI5 LI4 LI3 LI2 LI1 +24 PWR ATV61Hppppp Reference potentiometer 0 ± 10 V or X-Y mA Logic input switch (SW1) The logic input switch (SW1) is used to adapt the operation of the logic inputs to the technology of the programmable controller outputs. • Set the switch to Source (factory setting) if using PLC outputs with PNP transistors. • Set the switch to Sink Int or Sink Ext if using PLC outputs with NPN transistors. ATV61Hppppp 0V LI6 LI5 LI4 LI3 Ext 0V LI6 LI5 LI4 LI3 LI2 Sink Int LI2 SW1 LI1 Ext A1 Source ATV61Hppppp +24 Sink A1 Int +24 Source SW1 • SW1 switch set to "Source" position and use of an external power supply for the LIs LI1 • SW1 switch set to "Source" position 24V c source +24 V 0V ATV61Hppppp 0V LI6 LI5 LI4 Ext LI3 Int LI2 0V LI6 LI5 LI4 LI3 LI2 Sink LI1 Ext A1 Source ATV61Hppppp SW1 +24 Sink A1 Int +24 Source SW1 • SW1 switch set to "Sink Ext" position LI1 • SW1 switch set to "Sink Int" position 24V c source +24 V 0V WARNING Unintended Equipment Operation • When the SW1 switch is set to "Sink Int" or "Sink Ext", the common must never be connected to ground or the protective ground, as there is then a risk of unintended equipment operation on the first insulation fault. Failure to follow this instruction can result in death or serious injury. 35 Connection diagrams Bipolar speed reference A1 - 10 V COM + 10 V AI1- AI1+ ATV61Hppppp ±10 V c source Speed reference using axis control A1 COM 0V - + AI1- AI1+ ATV61Hppppp Axis control ±10 V reference SW2 switch The LI6 logic input switch (SW2) makes it possible to use the LI6 input: - either as a logic input by setting the switch to LI (factory setting) - or for motor protection via PTC probes by setting the switch to PTC A1 0V LI6 ATV61Hppppp SW2 PTC LI Motor Control power supply via an external source The control card can be supplied via an external +24V c source A1 ATV61Hppppp 0V 24V c source 0V +24 V 36 P24 Connection diagrams I/O extension card connection diagrams R4B TH2- TH2+ AI3+ AI3- COM AI4 AO3 AO2 0V RP CLO VW3 A3 202 LO4 LO3 R4C LI11 0V +24 A1 R4A Connection diagram for extended I/O option card (VW3 A3 202) Source 0-20 mA 4-20 mA X-Y mA Motor 0 ± 10 V or X-Y mA R3B TH1- TH1+ CLO VW3 A3 201 LO2 LO1 R3C LI7 0V +24 A1 R3A Connection diagram for logic I/O option card (VW3 A3 201) Motor 37 Connection diagrams SW3/SW4 logic I/O switch • Switch in "Source" position and use of an external +24 V c source • Switch in "Source" position SW3 or SW4 SW3 or SW4 CLO LOp CLO LOp +24 LIp Ext Ext LIp Int VW3 A3 20p Int 0V Sink +24 VW3 A3 20p 0V Sink A1 Source A1 Source 24V c source +24V 0V • Switch in "Sink Int" position • Switch in "Sink Ext" position SW3 or SW4 CLO LOp Ext LIp Sink VW3 A3 20p Int 0V CLO LOp LIp 0V Int Ext A1 Source VW3 A3 20p +24 Sink SW3 or SW4 A1 +24 Source 24V c source +24V 0V WARNING Unintended Equipment Operation • When the SW3 or SW4 switches are set to "Sink Int" or "Sink Ext", the common must never be connected to ground or the protective ground, as there is then a risk of accidental starting on the first insulation fault. Failure to follow this instruction can result in death or serious injury. 38 Connection diagrams Connection of several drives in parallel on the DC bus Connection in parallel on the DC bus is recommended in applications for which full motor power must be guaranteed. Each drive uses its own charging circuit 3 a 2 PO T / L3 S / L2 T / L3 R / L1 F3 M2 3 a W / T3 PC/- W3 V3 V / T2 U / T1 PO 3 ATV61Hppppp PC/- U3 V / T2 U / T1 V2 U2 W / T3 2 ATV61Hppppp PC/- W2 R / L1 S / L2 F2 T / L3 W1 V / T2 U / T1 V1 U1 M1 3 a Drives 1 , PO 1 ATV61Hppppp W / T3 R / L1 S / L2 F1 M3 3 a and 3 must not be more than one size apart when they are connected in this way. F1, F2, F3: fast-acting semiconductor fuses for protection on the DC bus side. 39 Operation on an IT system IT system: Isolated or impedance grounded neutral. Use a permanent insulation monitor compatible with non-linear loads, such as a Merlin Gerin type XM200 or equivalent. Altivar 61 drives feature built-in RFI filters. These filters can be isolated from ground for operation on an IT system as follows: Remove the jumper located to the left of the power terminals Normal (filter connected) IT system (filter disconnected) CAUTION When the filters are disconnected, the drive switching frequency must not exceed 4 kHz. Refer to the programming manual for the corresponding parameter setting. Failure to follow this instruction can result in equipment damage. 40 Electromagnetic compatibility, wiring Electromagnetic compatibility Principle • Grounds between thedrive, motor and cable shielding must have "high frequency" equipotentiality. • Use of shielded cables with shielding connected to ground at both ends for the motor cables, braking resistor (if used) and control-signal wiring. Conduits or metal ducting can be used for part of the shielding length provided that there is no break in continuity. • Ensure maximum separation between the power supply cable (line supply) and the motor cable. Installation diagram ATV61H 075M3 to D15M3X and ATV61H 075N4 to D18N4 • Attach and ground the shielding of cables 4 and 5 as close as possible to the drive: - Strip the shielding. - Use stainless steel metal clamps on the parts from which the shielding has been stripped, to attach them to the metal plate 2. The shielding must be clamped tightly enough to the metal plate to ensure correct contact. • Install the control EMC plate 11 on the sheet steel grounded plate 2, as shown in the diagram. • Attach and ground the shielding of cables 7, 12 and 13 as close as possible to the drive: - Strip the shielding. - Use stainless steel metal clamps on the parts from which the shielding has been stripped, to attach them to the control EMC flange 9. The shielding must be clamped tightly enough to the metal plate to ensure correct contact. 1 Altivar 61 2 Sheet steel grounded plate supplied with the drive 1 8 9 2 3 10 4 3 Tapped holes for installing the control EMC plate. 4 Shielded cable for motor connection with shielding connected to ground at both ends. The shielding must be continuous and intermediate terminals must be in EMC shielded metal boxes. 5 Shielded cable for connecting the braking resistor (if used). The shielding must be continuous and intermediate terminals must be in EMC shielded metal boxes. 5 6 Non-shielded wires for relay contact output. 7 Shielded cables for connecting the Power Removal safety function input. The shielding must be continuous and intermediate terminals must be in EMC shielded metal boxes. 8 Metal clamps 9 Connection to the protective ground 11 10 Unshielded power supply wires or cable 12 13 6 11 Control EMC plate 7 12 Shielded cables for connecting the control-signal cables. For applications requiring several conductors, use cables with a small cross-section (0.5 mm2 - AWG 20). 13 Shielded cables for connecting the encoder. The shielding must be continuous and intermediate terminals must be in EMC shielded metal boxes. Note: • If using an additional input filter, it should be mounted under the drive and connected directly to the line supply via an unshielded cable. Link 10 on the drive is then via the filter output cable. • The HF equipotential ground connection between the drive, motor and cable shielding does not remove the need to connect the PE protective conductors (green-yellow) to the appropriate terminals on each unit. 41 Electromagnetic compatibility, wiring Installation diagram ATV61H D18M3X to D45M3X and ATV61H D22N4 to D75N4 Attach and ground the shielding of cables 4 and 5 as close as possible to the drive: - Strip the shielding. - Use stainless steel metal clamps on the parts from which the shielding has been stripped, to attach them to the metal plate 2. The shielding must be clamped tightly enough to the metal plate to ensure correct contact. • Attach and ground the shielding of cables 6, 7 and 8 as close as possible to the drive: - Strip the shielding. - Use stainless steel metal clamps on the parts from which the shielding has been stripped, to attach them to the drive. The shielding must be clamped tightly enough to the metal plate to ensure correct contact. 1 1 Altivar 61 2 Sheet steel grounded plate supplied with the drive 3 Metal clamps 10 2 3 11 4 5 4 Shielded cable for motor connection with shielding connected to ground at both ends. The shielding must be continuous and intermediate terminals must be in EMC shielded metal boxes. 5 Shielded cable for connecting the braking resistor (if used). The shielding must be continuous and intermediate terminals must be in EMC shielded metal boxes. 6 Shielded cables for connecting the control-signal cables. For applications requiring several conductors, use cables with a small cross-section (0.5 mm2 - AWG 20). 7 Shielded cables for connecting the Power Removal safety function input. The shielding must be continuous and intermediate terminals must be in EMC shielded metal boxes. 8 Shielded cables for connecting the encoder. The shielding must be continuous and intermediate terminals must be in EMC shielded metal boxes. 9 Non-shielded wires for relay contact output. 6 7 10 Connection to the protective ground 11 Unshielded power supply wires or cable 8 9 Note: • If using an additional input filter, it should be mounted under the drive and connected directly to the line supply via an unshielded cable. Link 4 on the drive is then via the filter output cable. • The HF equipotential ground connection between the drive, motor and cable shielding does not remove the need to connect the PE protective conductors (green-yellow) to the appropriate terminals on each unit. 42 atv61s_installation_manual_en_v2 2005-09 ">

Download
Just a friendly reminder. You can view the document right here. But most importantly, our AI has already read it. It can explain complex things in simple terms, answer your questions in any language, and help you quickly navigate even the longest or most compilcated documents.
Advertisement
Key features
- Variable speed control
- Asynchronous motor control
- Precise speed regulation
- Enhanced motor protection
- Easy installation and wiring
- Flexible programming options
- Wide range of models
- Option cards for added functionality
- EMC compliance
- Safety features
Frequently asked questions
Altivar 61 drives are available for both single-phase (200…240 V) and three-phase (380…480 V) supply voltages. The specific voltage range for your drive is indicated on the nameplate.
Altivar 61 drives can be wall-mounted or floor-standing in a dust and damp proof enclosure. The mounting recommendations are detailed in the manual. Ensure adequate ventilation and follow the specific requirements for each drive rating.
Altivar 61 drives offer various option cards, including, I/O extension cards, communication cards, encoder interface cards, and a "Controller Inside" programmable card. The specific option cards depend on the drive rating and the desired functionality.
The manual emphasizes safety precautions, such as disconnecting power before servicing, grounding the drive, and coordinating overcurrent protection. It also highlights the importance of using appropriate protective devices and following wiring recommendations.